Rev 1, 12 Jan 2015

Programming details for Single use USB Data Logger


Models MS-ST-S-8 & MS-ST-S-8-P
Please input your required data in the highlighted cells
Details
Your Input
Customer name:
Your Time Zone
Day time savings (Yes/No)
Readings in Deg C or Deg F?
Sampling interval (seconds)

Example
GMT+4
Yes
Deg C

Description
Please give your details for reference
Please indicate your time Zone, where the data will be recorded
Please indicate Yes if your time zone has day time savings
Please indicate whether you want to be in Deg C or Deg F?

60.00 Seconds The frequency can be programmed from 5 seconds to 17 hours. eg. If sampling interval is
programmed to be 60 seconds, the temperature reading will be recorded every 60 seconds
This also will decide the total duration of recording.
The logger has a memory capacity to record 7928 readings. Hence if sampling interval is 60
seconds, it will record for 5.5 days
If sampling interval is every 3 minutes, it will record for 16.5 days
If sampling interval is every 5 minutes, it will record for 27.5 days

Start Delay (minutes)

High High Alarm

High Alarm
Low Alarm
Low Low Alarm
Total delay before alarm

Consecutive delay before alarm

10.00 Minutes This decides the delay to start recording after pressing the start button. Eg. If delay is 10
minutes, the logger will start recording 10 minutes after starting the logger
eg. If you are planning to keep the logger inside a 2-8 Deg box, it is better to keep 10 minutes
delay.
Other wise when the logger is started outside the box, the first few readings may be recorded in
the room temperature.
10 C, 3 minutes The second red LED will be activated once the temperature goes above this temperature for the
delay period. LED will start blinking if temperature goes above 10C for 3 minutes
8 C, 3 minutes The first red LED will be activated once the temperature goes above this temperature for the
delay period
2 C, 3 minutes The first Blue LED will be activated once the temperature goes below this temperature for the
delay period
0 C, 3 minutes The second Blue LED will be activated once the temperature goes below this temperature for
the delay period
5 Input any value between 1 and 254. If you enter 5, the alarm LED will not be triggered unless 5
readings are recorded above the alarm level for 5 times. (5 times during the entire duration, not
necessarily to be consecutive)
4 Input any value between 1 and 254. If you enter 4, the alarm LED will not be triggered unless 4
consecutive readings are recorded above the alarm level for 4 times.

If you want to program the device yourself, please check the link:
Details of SIngle use Disposable Data Logger
VackerGlobal
306, RKM Bldg, Deira,Dubai, United Arab Emirates
www.vackerglobal.com, Email: info@vackerglobal.com
Tel:+971 42 66 11 44