You are on page 1of 4

Medium voltage netowork management

Easergy Flair 21D - 22D - 23DV


Keep an eye on your fault current

Easergy Flair 21D - 22D - 23DV


For reliable fault current indication

High performance indicators


Phase to phase and phase to earth fault indication
All Flair 2xD range products gather to functions of phase to phase

short circuit detection and earth fault detection.

Faulty phase indication

All flair 2xD range products provide clear display of the faulty

phase

Suited to all neutral earthing systems

The setting range allows detection of all faults on isolated


impedant or directly earthed networks.
Earth fault detection sensitivity (<5A) allows fault detection on
compensated neutral networks.

Compatible with HV/MV susbstation protection


devices

All the products in the flair 2xD range integrate the selectivity with
extremely inverse time protection curves for earth faults

Clear and comprehensive display


Display of the faulty phase for earth faults
Display of settings
Display of load current
Maximeter
Frequency

Easergy Flair 21D - 22D - 23DV


For reliable fault current indication

Easy installation
Compact unit

DIN 93mmx45mm format


Secure attachment stopping extraction
Screw terminal connection
Assembly in all MV cubicile types (RM6, SM6, others)

Opening current sensors


Assembled on MV cables
Opening zero sequence coil

Maintenance-free
Self powered

Powered by one of the measurement sensors


4 hours minimum power reserve
Power supply of the indicator light and the display

Dual power

Lithium battery

External power supply


12Vdc to 48Vdc

Easergy Flair 21D - 22D - 23DV


Compatible with all MV cubicle types

RM6 compact switchboard

SM6 modular switchboard

A comprehensive range
References

Description

Self-powered fault current indicator : Flair 21D


Flair 21D

Self-powered detector
Indicator light - reset - 4 digit display
External indicator light output
ART59040 Schneider Electric Industries SAS - All rights reserved

SCADA output
Dual-powered fault current indicator : Flair 22D
Flair 22D

Self and lithium battery - powered selector


Indicator light - reset - 4 digit display
External indicator light output
SCADA output

External-powered fault current indicator : Flair 23DV


Flair 23DV

External 12Vdc to 48 Vdc powered detector


Indicator light - reset - 4 digit display
External indicator light output
SCADA output
Voltage presence/absense detection - 2 relay outputs - configurable delay

Schneider Electric Industries SAS


89, boulevard Franklin Roosevelt
F-92505 Rueil-Malmaison cedex
Tel : +33 (0) 1 41 29 85 00
www.schneider-electric.com
AMTED103021EN

As standards, specifications and designs change from time to time, please ask for
confirmation of the information given in this publication.
This document has been printed on ecological paper

Publishing: Schneider Electric IndustriesSAS


Design: Schneider Electric Industries SAS
Printing: Imprimerie des Deux Ponts - made in France

01-2010