EC-1305

POWER AMPLIFIERS / SETTING ADJUSTERS


FOR PROPORTIONAL ELECTRO-HYDRAULIC PROPORTIONAL
CONTROLS
CONTROL VALVES
Power Amplifiers
These are power amplifiers to be used exclusively to operate the electro-hydraulic proportional valves. Various type
and models on available for a variety of applications.

Type

Model Numbers

Applicable to
Control Valve

AME-D-10--20

Pressure and
Flow Control
(For 10 Sol.)

AME-D-S--32

Flow Control
(For 40 Sol.)

DC Input
AME-D2-H1--12
AME-D2-1010--10

Pressure and
Flow Control
(For 40 -10 Sol.)
Pressure and
Flow Control
(For 10 -10 Sol.)

SK1022---11

Pressure and
Flow Control
(For 10 Sol.)

AME-DF-S--22

Flow Control
(For 40 Sol.)

AME-T-S--22

Flow Control
(For 40 Sol.)

DC Input-Feedback

Slow Up-Down

SK1015-11
Pressure and
Flow Control
(For 10 Sol.)
AMN-D-10
DC Input
For DC Power
24 V DC
SK1091-D24-10

Directional and
Flow Control

Function

Page

By giving the command of DC voltage (0-10 V) to the amplifier,


current in proportion to that voltage will flow into the solenoid of
the control valve in order to control pressure or flow rate.
An external setting unit which makes the command voltage of 0-10
V and a DC power supply (or a function generator) are necessary,
but if a variable resistor for external setting is only one, the internal
power supply for amplifier can be used.

14
Variable
Resistor
1 k
Amplifier

Valve

Basically, this is a DC input type with a feedback operating unit. This


is for high-accuracy control and used to feedback the pressure or flow
rate converted to electric signals.

14

A slow up-down signal generator and the functions of a DC input


type are incorporated. This is used to control the pressure or flow
rate by slow up-down pattern and the command signals are given by
relay contacts, limit switches, timer contacts, etc.
An amplifier which is operated by a battery power supply (24V).
By giving the command of DC voltage to the amplifier, current in
proportion to that voltage will flow in the solenoid of the control
valve in order to control pressure or flow rate.
An external setting unit which makes the command voltage and a DC
power supply (or a function generator) are necessary, but if a variable
resistor for external setting is only one, the internal power supply for
amplifier can be used.
Variable
Resistor

18
Amplifier

Valve

SK1015 amplifier can be used in automobile construction machine.

No.1

POWER AMPLIFIERS / SETTING ADJUSTERS


FOR PROPORTIONAL ELECTRO-HYDRAULIC PROPORTIONAL
CONTROLS
CONTROL VALVES
Setting Adjusters
The setting adjuster supplies the command signal voltage to the power
amplifier. Since the setting adjuster is closely related to actual machine
operating procedure, the user generally provides this device.
Yuken makes the following standard setting adjusters for general use and
designs and manufactures special setting adjusters to order:

Type

Model Numbers

Function

Page

MC-01

This is the simplest setting adjuster, consisting of a trimmer (1 k ) and a dial.

18

MC-02

Consisting of a centre-tapped trimmer (1 k -1 k ) and a dial, this setting


adjuster is ideal for a servo system.

18

6-point Setting Adjuster

AMC-V6-S--10

Six trimmers are incorporated, so it is possible to set six points.

19

Multifunction Slope
Controller

AMC-T-20

This multifunction slope controller generates any desired 2-channel analog voltage
pattern outputs. It can also be used with slope-proportional and time-proportional
systems.

20

Manually Operated
Setting Adjuster

Instructions for Power Amplifiers


The power amplifiers should be kept away from hot and humid conditions which may deteriorate some components of
the power amplifiers. They also should be installed in the clean and dry place where the vibration is minimal.
Please avoid to install the power amplifiers in the complete enclosure or get them enclosed totally as they need to radiate
the heat from semiconductors or ICs inside.
Please use shielded wires for input signal transmission to prevent the amplifiers from any interference such as noise from
outside.

No.2

Power Amplifiers
For 10 Series Control Valves
Specifications / Others

PROPORTIONAL
CONTROLS

These power amplifiers are used to drive the 10 series proportional


electro-hydraulic pressure and flow control valves.

Model Number Designation

AME

-D

-10

-100

-20

Series
Number

Type of Function

Coil Resistance
of Valve

Power Supply

Design
Number

AME

D : DC Input Type

10 : 10

100 : 100 V AC
200 : 200 V AC

20

Applicable to Valve

SK1022

-A

Series Number

-100

Type of Function

SK1022 :
DC Input-Feedback
Type

-11

Power Supply

A : Polarity of Feedback
Voltage...(-)

100 : 100 V AC

B : Polarity of Feedback
Voltage...(+)

200 : 200/220 V AC

Design
Number

11

SK1015 :
DC Input Type
for DC Power
Supply

11

Name of Valve

Model Numbers

Pilot Relief Valves

EDG-01

Relief Valves

EBG-03
EBG-06
EBG-10

Reducing and
Relieving Valves

ERBG-06
ERBG-10

10 Series
Flow Control Valves

EFG - 03
EFCG 06

10 -10 Series
High Flow Series
Flow Control and
Relief Valves

EFBG-03
EFBG-06
EFBG-10

Use with 24 V DC since this is for a battery power supply.

Specifications
Model No.

AME-D-10--20

SK1022-A--11

SK1022-B--11

SK1015-11

DC Input Type

DC Input
Feedback Type

DC Input
Feedback Type

DC Input Type

Max. Output Current

1 A (10 Solenoid)

1 A (10 Solenoid)

1 A (10 Solenoid)

0.9 A (10 Solenoid)

Max. Input Voltage

+ 10 V DC

+ 10 V DC

+ 10 V DC

+ 10 V DC

0 to -10V

0 to +10V

Description
Type of Fuction

Feedback Voltage
10 k

50 k

50 k

50 k

Max. Gain

1A/5V

1 A / 0.5 V

1 A / 0.5 V

0.9 A / 5 V

Dither

Variable

Fix

Fix

Fix

0.2 mA /C

0.2 mA /C

0.2 mA /C

1 mA /C

Input Impedance

Temperature Drift (Max.)


Power Supply
Power Input (Max.)
Ambient Temperature
External Setting Resistance
Approx. Mass

100 V AC, 200 V AC


(50/60 Hz)

100 V AC, 200/220 V AC 10% (50/60 Hz)

22-30 V DC

55 VA

45 VA

45 VA

25 VA

0-50C (32-122F)

0-50C (32-122F)

0-50C (32-122F)

0-50C (32-122F)

1 k

1 k

1 k

10 k

2.1 kg (4.6 lbs.)

4.5 kg (9.9 lbs.)

4.5 kg (9.9 lbs.)

0.4 kg (.88 lbs.)

Serviceable Range; 100 V AC can be used from 90 to 132 V AC, 200 V AC can be used from 180 to 264 V AC.

Instructions
Power supply for the setting adjuster can be provided from this power amplifier, but for only one. However, please use
the variable resistor or potentiometre of which impedance is 1 k (in case of model SK1015, use 10 k ) for the
setting adjuster.

No.3

Power Amplifiers
For 10 Series Control Valves

PROPORTIONAL
CONTROLS

Installation Drawing
AME-D-10--20

Terminal Board
Terminal
Number

[Example Diagram]

1
2
3
4
5

Setting Adjuster
MC-01

220

+12V

DITHER
MAX

MIN

1 k

SOL

7
8
9
10
11
12

8
10

11

12

Power Supply

Ammeter
(Output Current)

Max. Adjuster

Zero Adjuster

Name
Input Signal
Input Signal

IN
COM

Input Signal

COM

Internal Power Supply


(10 V at 1 k )
Output to Valve
Solenoid

+12 V
SOL

Ground
Power Supply
100/200 V AC

Terminal Board
(Refer to table above)

MIN

199(7.83)

MAX

Power Fuse

189(7.44)

CURRENT
MONITOR

IN
COM

COM

12V

Supply Switch
F

SOL

DITHER

POWER

4.5(.18) Dia. Through


4 Places

1
2
3
4
5
6
7
8

G
AC

9
10
11
12

178(7.01)

POWER AMP

Dither Adjuster
Indicator Lamp

70
(2.76)
80
(3.15)

25
(.98)

170
(6.69)
185.5
(7.30)

76
(2.99)

1. Adjustment of upper limit of usable range


2. Adjustment of lower limit of usable range

DIMENSIONS IN
MILLIMETRES (INCHES)

No.4

Power Amplifiers
For 10 Series Control Valves

PROPORTIONAL
CONTROLS

Installation Drawing
SK1022-A--11
B

Terminal Board

[ Example Diagram ]
Setting Adjuster
MC-01
470

10

15V
REF

DITHER

1
GAIN

1 k

SOL
8

11
3

F.B

NULL

Terminal
Number
1
2
3
4
5
6
7
8
9

Name

Pressure
Sensor

12

13

14

Output to Valve
Solenoid

SOL

Terminal Board
(Refer to table above)

GAIN

199(7.83)

NULL

FB

189(7.44)

REF COM

Feedback 3
Adjuster
Gain Adjuster

SOL

Power Fuse
100 V AC : 2A
200/220 V AC :
1A

Indicator Lamp

+15V
G
AC

POWER

F1

8 REF
9 COM

1
2

10 F.B
11COM
12
13

3
4
5
6

14

178
(7.01)

Check Terminal
3 Places

Zero 2
Adjuster
Supply
Switch

Power Supply
100 V AC, 200V AC : 13, 14
220 V AC : 12, 14

Ammeter (Output Current)

Reference
Adjuster

+15V

Ground

11
12
13
14

Power Supply

REF
COM
F.B
COM

Power Supply for


Setting Adjuster
(10 V at 1 k)

10

Input Signal
Input Signal
Feedback Signal
Feedback Signal

Output
Fuse (2A)

F2

4.5(.18) Dia.
Through
4 Places

1.
2.
3.
4.

120
(4.72)

240(9.45)

105(4.13)
125(4.92)

22
(.87)

260(10.24)

Adjustment of upper limit of usable range


Adjustment of lower limit of usable range
Adjustment of feedback voltage ratio
Adjustment of input voltage ratio

DIMENSIONS IN
MILLIMETRES (INCHES)

SK1015-11

1 k

Blue

White

Black

1
2
3
4
5
6
7

GAIN

Blue

Black
10 k

100(3.94)

NULL

Red

SOL

4(.16) Dia.
Through
4 Places

45
(1.77)

3
(.12)

75(2.95)
85(3.35)

Setting
Adjuster
Yellow

120(4.72)

Lead Wire
Approx.
200
(7.87)

[ Example Diagram ]

24 V DC

Zero Adjuster

Gain Adjuster

Lead Wire Detail


1
2
3
4
5
6
7

White........Plus of 24 V DC
Black........Zero of 24 V DC
Blue..........
Blue.......... Output to Valve Solenoid
Yellow......15 V Power Supply for Setting Adjuster (10 V at 10 k)
Red...........Input Signal
Black........Zero of Input Signal

1. Adjustment of upper limit of usable range


2. Adjustment of lower limit of usable range

No.5

Power Amplifiers
For 10 Series Control Valves

PROPORTIONAL
CONTROLS

Specifications / Others
Compact power amplifiers for 10 proportional solenoids. The power
supply is 24 V DC. It uses a new circuitry to be slow to heat.

Model Number Designation

AMN

-D

-10

Series Number

Type of Function

Design
Number

AMN

D : DC Input Type

10

Specifications

Applicable to Valve

Model No.

Name of Valve

AMN-D-10

Description
Type of Function

DC Input Type

Max. Output Current

1 A (10 Solenoid)

Power Input (Max.)

+ 10 V DC
10 k

Input Impedance
Max. Gain

1A/5V

Dither

Variable

Temperature Drift (Max.)

0.2 mA /C

Power Supply

24 V DC (20 - 30 V DC)

Max. Input Power

25 W

Ambient Temperature

Model Numbers

Pilot Relief Valves

EDG-01

Relief Valves

EBG-03
EBG-06
EBG-10

Reducing and
Relieving Valves

ERBG-06
ERBG-10

10 Series
Flow Control Valves

EFG - 03
EFCG 06

10 -10 Series
High Flow Series
Flow Control and
Relief Valves

EFBG-03
EFBG-06
EFBG-10

0 - 50C (32 - 122F)


1 k

External Setting Resistance


Approx. Mass

0.2 kg (.44 lbs.)

AMN-D-10

DIMENSIONS IN
MILLIMETRES (INCHES)

[Example Diagram]
Setting Adjuster
MC-01

MIN

+12V

3.5(.14) Dia.
Through
2 Places

5
SPAN

1 k

SOL

Zero Adjuster

Power Supply
Span Adjuster

POWER

100(3.94)

SPAN

90(3.54)

MIN

DITHER

Terminal Board
Terminal
Number
1
2
3
4
5
6
7
8

No.6

1 2 3 4 5 6 7 8

Name
Power Supply
Power Supply
Ground
Internal Power Supply
Input Signal
Input Signal
Output to Valve
Solenoid

+24 V
0V
G
+12 V
IN
COM
SOL

Terminal Board
(Refer to table on
the left.)
2.5
(.10)
30
(1.18)

50
(1.97)
60
(2.36)

Indicator
Lamp

Power Amplifiers
For 40 Series Control Valves
Specifications / Others

PROPORTIONAL
CONTROLS

These power amplifiers are used to drive the 40 series proportional


electro-hydraulic flow control valves.

Model Number Designation

AME
Series
Number

-D

-S

-100

-32

Type of Function

Type of
Mounting

Power Supply

Design
Number

S : Panel
Mounting
Type

100 :
100 V AC
200 :
200/220 V AC

32

D : DC Input Type
AME

DF : DC Input
Feedback Type
T : Slow Up Down
Type

22
22

Applicable to Valve
Name of Valve

Model Numbers

40 Series
Flow Control Valve

EFG -02/03/06/10
EFCG

40 -10 Series
Flow Control and
Relief Valve

EFBG-03/06/10

Specifications
Model No.
Description
Type of Function

AME-D-S--32

AME-DF-S--22

AME-T-S--22

DC Input Type

DC Input Feedback Type

Slow Up Down Type

Max. Output Current

0.8 A (40 Solenoid)

0.8 A (40 Solenoid)

0.8 A (40 Solenoid)

Max. Input Voltage

+ 10 V DC

+ 10 V DC

Feedback Voltage
Input Impedance

0 to -10 V
10 k

50 k

0.8 A / 5 V

0.8 A / 5 V

Slow Up Down Range


Max. Gain
Dither
Temperature Drift (Max.)

0.05 to 1 s /100 mA
Fix

Fix

Fix

0.2 mA /C

0.2 mA /C

0.2 mA /C

100 V AC, 200/220 V AC 10% (50/60 Hz)

Power Supply
Power Input (Max.)
Ambient Temperature
External Setting Resistance
Approx. Mass

90 VA

90 VA

90 VA

0-50C (32-122F)

0-50C (32-122F)

0-50C (32-122F)

1 k

1 k

4.5 kg (9.9 lbs.)

4.5 kg (9.9 lbs.)

4.5 kg (9.9 lbs.)

Instructions
When DC input type (AME-D-S) or DC input-feedback type (AME-DF-S) power amplifier is used, power supply for
the setting adjuster can be provided from this power amplifier, but for only one. However, please use the variable
resistor or potentiometre of which impedance is 1 k for the setting adjuster.

No.7

Power Amplifiers
For 40 Series Control Valves

PROPORTIONAL
CONTROLS

Installation Drawing
AME-D-S--32

Terminal Board
Terminal
Number

[Example Diagram]

1
2
3
4
5
6
7
8
9

Setting Adjuster
MC-01

10 470

15V
DITHER

GAIN

1
1 k

NULL

SOL

9
11

12

Name

13 14

Output to Valve Solenoid SOL


Power Supply for Setting
+15 V
Adjuster (10 V at 1 k )
Ground
G

10

Power Supply

IN
COM

Input Signal
Input Signal

11
12
13
14

Power Supply
100 V AC, 200 V AC: 13, 14
220 V AC: 12, 14

Ammeter
(Output Current)

NULL

GAIN

Supply Switch

199(7.83)

Gain Adjuster
189(7.44)

Zero Adjuster

POWER

4.5(.18) Dia.
Through
4 Places

Indicator
Lamp
105
(4.13)
125
(4.92)

240
(9.45)
260
(10.24)

22
(.87)

Terminal Board
(Refer to table above)

8
9
10
11
12
13
14

SOL
+15V
G

DIMENSIONS IN
MILLIMETRES (INCHES)

Power Fuse
100 V AC: 3 A
200/220 V AC: 1.5 A

AC

1
2
3
4
5
6
7

IN
COM

F1

F2

120
(4.72)

View Arrow X

No.8

178(7.01)

1. Adjustment of upper limit of usable range


2. Adjustment of lower limit of usable range

Output
Fuse (1.5 A)

Power Amplifiers
For 40 Series Control Valves

PROPORTIONAL
CONTROLS

Installation Drawing
AME-DF-S--22

Terminal Board
Terminal
Number

[Example Diagram]
Setting Adjuster
MC-01

10

470

15V
DITHER

REF

1
GAIN

1 k

SOL

8
11
F.B

NULL

Name

1
2
3
4
5
6
7
8
9

Input Signal
Input Signal
Feedback Signal
Feedback Signal

Output to Valve Solenoid SOL


Power Supply for Setting
+15 V
Adjuster (10 V at 1 k )
Ground
G

10

Sensor

12

13

14

11
12
13
14

Power Supply

IN
COM
F.B
COM

Power Supply
100 V AC, 200 V AC: 13, 14
220 V AC: 12, 14

Ammeter
(Output Current)
Check Terminal
3 Places
Reference Adjuster

Feedback Adjuster

Supply Switch

REF COM

NULL

FB

GAIN

POWER

199(7.83)

189(7.44)

Zero Adjuster

Gain Adjuster

Indicator Lamp

4.5(.18) Dia.
Through
4 Places
240
(9.45)
260
(10.24)

22
(.87)

Terminal Board
(Refer to table above)

1. Adjustment of upper limit of usable range


2. Adjustment of lower limit of usable range
3. Adjustment of feedback voltage ratio
4. Adjustment of input voltage ratio

8
9

SOL

10
11
12
13
14

+15V
G

DIMENSIONS IN
MILLIMETRES (INCHES)

AC

Power Fuse
100 V AC: 3 A
200/220 V AC: 1.5 A

F1

REF

1
2

COM
F.B

3
4
5
6
7

COM

F2

178(7.01)

105
(4.13)
125
(4.92)

Output
Fuse (1.5 A)

120
(4.72)

View Arrow X

No.9

Power Amplifiers
For 40 Series Control Valves

PROPORTIONAL
CONTROLS

Installation Drawing
AME-T-S--22

Terminal Board

[Example Diagram]

1
2
3
Limit Switch

4
10

CH1

CR1

DITHER

Input Command

CR1

Input Command

CR2

Input Command

CR3

Input Command

CR4

SOL

CR3

Output to Valve Solenoid

SOL

6
7

CH2

Sequence Holding
Circuit

Name

CR2

CR4

Trminal
Number
1

14

10

Input Command

Power Supply

11

Ground

12 13

12

CR. COM
G

Power Supply

13

100 V AC, 200 V AC: 13, 14

14

220 V AC: 12, 14

Ammeter (Output Current)


Indicator Lamp
(CH2)

Terminal Board
(Refer to table above)

Indicator Lamp
(CH1)

MIN

MAX

MIN

UP

DOW

UP

DOW

POWER

NULL

Power Fuse
100 V AC : 3A
200/220 V AC :
1.5 A

Null Adjuster

4.5(.18) Dia.
Through
4 Places
Indicator Lamp

105(4.13)
125(4.92)

F1

F2

Output
Fuse
(1.5 A)

120
(4.72)

240(9.45)
260(10.24)

22
(.87)

1
2
3
4
5
6
7

8
9
10
11
12
13
14

178
(7.01)

Supply Switch

MAX

189(7.44)
199(7.83)

CH2 Adjuster

CH1 Adjuster

[Output Current Pattern]


CH1
(Channel 1)
Current
MAX.1

DOWN.1

UP.1
NULL

DIMENSIONS IN
MILLIMETRES (INCHES)

CH2
(Channel 2)
DOWN.2

MAX.2
UP.2

MIN.1

MIN.2
Time
Terminal
1 & 10 in Short-Circuit

CR1.ON

2 & 10 in Short-Circuit

CR2.ON
CR3.ON
CR4.ON

3 & 10 in Short-Circuit
4 & 10 in Short-Circuit

Note: 1. CR1 to CR4: Relays in the power amplifier.


The output patterns CH1 and CH2 can not be obtained simultaneously nor can they be transmitted halfway to
another pattern.
2. The words such as MAX, MIN, UP and DOWN show the volume adjustment of the power amplifier.

No.10

Power Amplifiers
For 40 Series Control Valves
How to Calculate Accelerating and Decelerating Time

PROPORTIONAL
CONTROLS

How to Calculate Accelerating and Decelerating Time (Example)

Question: Wish to accelerate and decelerate the actuator in between 5 L/min (1.32 U.S. GPM) and 25 L/min
(6.6 U.S. GPM) in the use of proportional flow control valve model EFG-02-30.
In such case, what are the maximum and minimum time adjustable for the acceleration and
deceleration?
Answer: The input current for EFG-02-30 at the flow rate of 5 L/min (1.32 U.S.GPM) and 25 L/min (6.6
U.S. GPM) can be obtained respectively from the chart below. The chart shows:
Input current at 5 L/min (1.32 U.S. GPM)
300 mA
Input current at 25 L/min (6.6 U.S. GPM)
520 mA
Then, the difference between the above two can be obtained with the following formula:
520 mA-300 mA=220 mA
While, the specification for the model AME-T-S shows the amplifier's gradient for acceleration
or deceleration as being between 0.05 s/100 mA and 1.0 s/100 mA (which means that the minimum
time is 0.05 second and the maximum time is 1.0 second for every 100 mA variation).
Therefore, the minimum and maximum adjustable time can be obtained as follows:

220 mA
0.05 second = 0.11 second (Minimum)
100 mA
220 mA
1.0 second = 2.2 second (Maximum)
100 mA
The result above are as illustrated on the below.

H
[Flow Pattern]

[Input Current vs. Flow]


EFG-02

U.S.GPM L /min
30
8

L /min
(U.S.GPM)

Flow Rate

25 L /min
(6.6 U.S.GPM)

25

5 L /min
(1.3 U.S.GPM)

Min.
0.11 s
Max. 2.2 s

Min.
0.11 s

Time s

Max. 2.2 s

Flow Rate

6
5
4
3

20
15
10

2
1
0

5
0
0

10

200 300 400 500

Input Current

600

mA

No.11

Power Amplifiers
For 40 -10 Series Control Valves

PROPORTIONAL
CONTROLS

Specifications / Others

These power amplifiers are specially designed to combine and


incorporate the functions of pressure control (10 solenoid) and
flow control (40 solenoid) into one and can be used for the
proportional electro-hydraulic flow control and relief valves of
which model numbers are as shown below.

Model Number Designation


AME

-D2

-H1

Series Number

Type of Function

Type of Mounting

AME

D2: DC Input Type

H1: Wall Tapestry Type

-100

-12

Power Supply

Design
Number

100: 100 V AC
200: 200/220 V AC

12

Applicable to Valve
Name of Valve
40- 10 Series
Flow Control and
Relief Valve

Model Numbers
03-125
EFBG-06-250-C
H
10-500

Specifications
Model No.
Description
Type of Function
Max. Output Current
Max. Input Voltage
Input Impedance
Max. Gain
Dither
Temperature Drift (Max.)
Power Supply
Power Input (Max.)
Ambient Temperature
External Setting Resistance
Approx. Mass

AME-D2-H1--12
Flow Controls (40 Solenoid)
Pressure Controls (10 Solenoid)
DC Input Type
DC Input Type
1 A (10 Solenoid)
0.8 A (40 Solenoid)
+10 V DC
+10 V DC
10 k
10 k
0.8 A / 5 V
1A/5V
Fix
Fix
0.2 mA /C
0.2 mA /C
100 V AC, 200/220 V AC 10% (50/60 Hz)
130 VA
0-50C (32-122F)
1 k
1 k
5.6 kg (12.3 lbs.)

Instructions
Power supply for the setting adjuster up to 2 set can be provided from this power amplifier. However, please use the
variable resistor or potentiometre of which impedance is 1 k for the setting adjuster.

No.12

Power Amplifiers
For 40 -10 Series Control Valves
Installation Drawing
AME-D2-H1--12

PROPORTIONAL
CONTROLS

Terminal Board
Terminal
Number

[Example Diagram]

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Flow Setting
Adjuster
20

DITHER

12V

19

Flow Control Valve

SPAN

9
17

MIN

18

DITHER
SPAN

8
6

40 SOL

Pres.Control Valve
10 SOL

TOFF TON
MIN

Pres. Setting
Adjuster

Terminal Board
(Refer to the table
on the right above.)

Pres. Zero-Point Adjuster

Flow Zero-Point Adjuster

Name
Power Supply
100 V AC, 200 V AC: 1, 2
220 V AC: 1, 3
G

Ground

Output to Pressure Control


Valve (10 ) Solenoid
PR. SOL
Ammeter
Output to Flow Control
Valve (40 ) Solenoid
Ammeter
Common

-12 V OUT
Common
+12 V OUT
Common
Input Signal for PRES.
Input Signal for FLOW
+12 V OUT

FL. SOL
COM

-12 V
COM
+12 V
COM
PR.IN
FL.IN
+12 V

F1

10

20

19

18

17

16

15

14

13

12

11

PRES FLOW

2
4

MIN
SPAN
T ON
T OFF

POWER

F2

Pres. Span Adjuster


Flow Span Adjuster

174
(6.85)

188(7.40)

200(7.87)

POWER
AMPLIFIER

Pres. Rising Time Adjuster


Indicator Lamp
Pres. Falling Time Adjuster

Flow Output Fuse


1.5 A
Pres. Output Fuse
2A

6(.24)
60
(2.36)

100(3.94)
220(8.66)

Supply Switch
145
(5.71)

1. Minimum Pressure Setting


2. Variable Pressure Range Setting
3. Minimum Flow Setting
4. Variable Flow Range Setting

DIMENSIONS IN
MILLIMETRES (INCHES)

No.13

Power Amplifiers
For 10 -10 Series Control Valves
Specifications / Others

PROPORTIONAL
CONTROLS

These power amplifiers can drive two solenoid of 10 load simultaneously


or separately, and the control can be done in the same way even though the
object is separated by pressure system and flow rate system. Although the
display of control unit on the front panel is PRESS and FLOW , they
are exactly the same circuit, so there is no distinction between the two system
when used.

Model Number Designation

AME
Series
Number
AME

-D2
Type of Function
D2 :
DC Input Type

Applicable to Valve

-1010

-100

Coil Resistance
of Valve
1010 : 10 2

Power Supply
100 : 100 V AC
200 : 200/220 V AC

-10
Design
Number

Model No.
Type of Function

AME-D2-1010--10
1 A (10 Solenoid)

Max. Input Voltage

+ 10 V DC

Max. Gain
Dither
Temperature Drift (Max.)
Power Supply
Power Input (Max.)
Ambient Temperature
External Setting Resistance
Approx. Mass

Relief Valves

EBG-03
EBG-06
EBG-10

Reducing and
Relieving Valves

ERBG-06
ERBG-10

10 Series
Flow Control Valves

EFG - 03
EFCG 06

10 -10 Series
High Flow Series
Flow Control and
Relief Valves

EFBG-03
EFBG-06
EFBG-10

DC Input Type

Max. Output Current


Input Impedance

Model Numbers
EDG-01

10

Specifications
Description

Name of Valve
Pilot Relief Valves

10 k
1A/5V

Applicable to Piston Pump


Name of Pump

Variable 100-300 mA
0.2 mA /C
100 V AC, 200/220 V AC 10% (50/60 Hz)
120 VA
0-50C (32-122F)
1 k
4.3 kg (9.5 lbs.)

"A" Series Variable


Displacement
Piston Pump
Proportional
Electro-Hydraulic
Load Sensing Type

Model Numbers
A16
A22
- -R-04
A37
A56
A70
A90 --R-04
A145
Also, double pumps
combined with the
models listed above
and fixed displacement vane pumps.

Instructions
Power supply for the setting adjuster up to 2 set can be provided from this power amplifier. However, please use the
variable resistor or potentiometre of which impedance is 1 k for the setting adjuster.

No.14

Power Amplifiers
For 10 -10 Series Control Valves

PROPORTIONAL
CONTROLS

Installation Drawing
AME-D2-1010--10

Terminal Board
Terminal
Number
1

[Example Diagram]

Flow
Setting Adjuster
17
16

DITHER

+12V
SPAN

MIN

14
15

FL.
SOL

DITHER
SPAN

MIN

PR.
SOL

Pressure
Setting Adjuster

Power Supply

Name
Power Supply

100 V AC, 200 V AC: 1, 2

220 V AC: 1, 3
G

Ground

Output to Pressure Control

Valve Solenoid

Ammeter

Output to Flow Control

Valve Solenoid

10

Ammeter

PR.SOL

FL.SOL

11

12 V OUT

12

Common

12 V
COM

13

+12V OUT

+12 V

14

Common

COM

15

Input Signal for PRES.

PR. IN

16

Input Signal for FLOW

FL. IN

17

+12V OUT

+12 V

Pres. Dither Adjuster


Pres. Span Adjuster

Terminal Board
(Refer to table on
the right above.)

Pres. Zero-Point Adjuster

Flow Zero-Point Adjuster

Flow Span Adjuster

POWER AMPLIFIER

6 +12V

13

5 COM

12

4 12V

11

PR
SOL
GND

Flow Dither Adjuster

FLOW

PRESS

15
MIN

14

Indicator Lamp

SPAN

DITHER

3
AC220V

2
AC200V

POWER

F3
US

F2
US

F1
US

188(7.40)

200(7.87)

16

AME-D2-1010-200-10

17

FL
IN
PR
IN
COM

FL
SOL

+12V

175
(6.89)

10

145
(5.71)

6(.24)
60
(2.36)

100(3.94)
220(8.66)
Power Fuse
100 V AC : 2A
200 V AC :1A

Supply Switch
Pres. Output Fuse
(1.5A)
Flow Output Fuse
(1.5A)

DIMENSIONS IN
MILLIMETRES (INCHES)

No.15

Power Amplifiers
For Directional and Flow Control Valves
Specifications / Others

PROPORTIONAL
CONTROLS

Model Number Designation

SK1091

-D24

-10

Series Number

Power Supply

Design Number

SK1091

D24 : 24 V DC

10

Applicable to Valve
Name of Valve

Model Numbers

Directional and
Flow Control Valve

03
EDFHG-04
06

Specifications
Model No.
Description

SK1091-D24-10

Max. Output Current

1 A (10 Solenoid)

Max. Input Voltage

-10 V DC for SOL a


+10 V DC for SOL b

Input Impedance
Max. Gain

10 k
1 A / 5 V

Dither

Variable

Delay Time Adjustment


Range

0.15-3 s

Temperature Drift (Max.)


Power Supply
Required Current
Power Input (Max.)

0.2 mA /C
24 V DC (21-28 V Included Ripple)
More than 1.5 A
25 W

Ambient Temperature

0-50C (32-122F)

Ambient Humidity

Less than 90%RH

External Setting Resistance


Approx. Mass

2 k
1.0 kg (2.2 lbs.)

Instructions
Power Supply for the Setting Adjuster
Power supply for the setting adjuster can be provided from this power amplifier, but for only one. However, please use
the variable resistor or potentiometre of which impedance is 2 k for the setting adjuster.
Power Switch
The power amplifier has no power supply switch. As soon as it is connected to a power supply , it comes to be alive.
Provide a power switch externally.

No.16

Power Amplifiers
For Directional and Flow Control Valves

PROPORTIONAL
CONTROLS

Installation Drawing
SK1091-D24-10

MINa

Setting Adjuster
4

For SOL a

DOWNa

UPa

MC-02

SPANa

+12V

8 SOLa

1
6
5
2 k

Output Current (A)

[Input-Output Characteristics]

[Example Diagram]

DELAY

-12V

SPAN a

10 SOLb

UPb

MIN a

11
DOWNb SPANb

14
24V

12

-V

DITHER

MINb

For SOL b

SPAN b
MIN b

Approx. 0.1V

Input Voltage

+V

0V

13

Power Supply

Terminal Board
Terminal
Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14

Name
Input Signal
Input Signal

IN
COM

Power Supply for Setting Adjuster


Power Supply for Setting Adjuster
Power Supply for Setting Adjuster

+12V
COM
-12V

Input Voltage 0

Output to Valve Solenoid

SOL a

Output Current 0

Output to Valve Solenoid

SOL b

[Delay Function]

+V

-V

24 V
0V
FG

Power Supply
Power Supply
Ground

UP b
DOWN b

UP a
DOWN a

DIMENSIONS IN
MILLIMETRES (INCHES)

Indicator Lamp
Delay Time
Adjuster
for SOL a
POWER

SOL a, b
Indicator Lamp
1

SOLa
SOLb

Delay Time
Adjuster
for SOL b

DOWNa

150(5.91)

SPANb

14

13

12

11

10

SPANa

180(7.09)

DOWNb

166(6.54)

UPb

UPa

Span Adjuster

MINa
MINb

DITHER

Zero-Point Adjuster
Terminal Board
(Refer to the table
on the above.)
6
(.24)

Dither Adjuster

10
(.39)

100
(3.94)

48
(1.89)

No.17

Setting Adjusters
Manually Operated Setting Adjusters
Installation Drawing

PROPORTIONAL
CONTROLS

MC-01
[Example Diagram]
Setting Adjuster
(MC-01)
3

3
Clockwise
Rotation
2

1k

[Mounting Panel]
M4 Thd.
4 Places

Power Amplifier
(AME-D-10)
6
7

62(2.44)
70(2.76)

[Electric Circuit]

10
1

11

12

Power Supply
62(2.44)
70(2.76)

70

20

80

10

3
2

90
0

60
(2.36)

60

30

80(3.15)

50

5(.20)

40

70(2.76)

4.5(.18) Dia.
Through
4 Places

2 3 4

100

YUKEN MODEL MC-01

70(2.76)

2.3(.09)

80(3.15)

30
(1.18)

60
(2.36)

60
(2.36)

10
(.39)

DIMENSIONS IN
MILLIMETRES (INCHES)

MC-02
[Example Diagram]

This setting adjuster is for using positive and


negative voltages to the right and left of the zero
point. Most suitable for servo systems.
Please contact us for usage details.

M4 Thd.
4 Places
Power Amplifier
SK1091-D24-10
4
+12V
1
Input
6
12V
5 0V

Setting Adjuster
(MC-02)
3
2

[Electric Circuit]

1
4

Servo Amplifier

1k

3
Clockwise
Rotation
2

1k

2k

[Mounting Panel]

62(2.44)
70(2.76)

[How to Use]

62(2.44)
70(2.76)

40
60

60

3
2
1

80

80
100

60
(2.36)

20 INC.

40

80(3.15)

70(2.76)

DEC. 20

5(.20)

4.5(.18) Dia.
Through
4 Places

2 3 4

100

YUKEN MODEL MC-02

70(2.76)
80(3.15)

No.18

2.3(.09)
30
(1.18)

60
(2.36)

10
(.39)

60
(2.36)

Setting Adjusters
6-Point Setting Adjusters

PROPORTIONAL
CONTROLS

Installation Drawing
AMC-V6-S--10

Terminal Board

Power Supply
100............100 V AC
200............200 V AC
220............220 V AC

[Electric Circuit]
12
AC
Power Supply

10 VDC
Power
Supply

13
14

10V

VR1

VR2 VR3 VR4

VR5

VR6

Terminal
Number
1

1 OUT (VR1)

2 OUT (VR2)

3 OUT (VR3)

4 OUT (VR4)

5 OUT (VR5)

6 OUT (VR6)

Name

0V

COM

0V

9
11

8(0V)

10

11

Ground

12
13

[Example Diagram]
Relay Circuit

Setting Adjuster
(AMC-V6-S)

1
2
3
4
5
6
8
13 14

14

Power Supply
85-265 V AC

Power Amplifier
(AME-D-S)

SOL

13 14 11

11
AC
Power Supply

Supply Switch

8
9
10
11
12
13
14

189(7.44)
199(7.83)

F1

POWER

70(2.76)
80(3.15)

1
2
3
4
5
6
7

178
(7.01)

Terminal Board
(Refer to the table above)

4.5(.18) Dia. Through


4 Places

Adjusting Dial
6 Places

Indicator
Lamp

22
(.87)

240(9.45)
260(10.24)

76
(2.99)
Power Fuse (1A)

DIMENSIONS IN
MILLIMETRES (INCHES)

No.19

Setting Adjusters
Multifunction Slope Controllers

PROPORTIONAL
CONTROLS

Specifications / Others
This controller can generate any desired 2-channel analog voltage pattern outputs
and can be used with slope-proportional and time-proportional systems.

Model Number Designation

AMC

-T

-20

Series Number

Type of Function

Design
Number

AMC : Setting Adjuster

T : Acceleration/deceleration signal type


(Slope Controller)

20

Specifications
Model No.

AMC-T-20

Description
Number of Output Channels

2 channels (A, B)

Maximum Output Range

0 - +5 V , 0 - 5 V, 0 - +10 V, 0 - 10 V (The settings are DIP switch selectable)

Two Categories of Slopes

Slope-constant
With a level change, the slope will not change (but arrival time changes.)
Time-constant
With a level change, the time will not change (but the slope changes.)

Acceleration/Deceleration
Signal Type

: 1 Type
4 Types Polygonal Line Signal
Curve Compensation Signal : 3 Types

Maximum Slope Time

The level and slope settings are variable in 0.1% units from 0 to 99.9%
Mode 1, 4-bit binary code input, 15 patterns
Mode 2, 6-bit binary code input, 63 patterns
Mode 3, Timer control, 9 patterns (4 variations)

Control Mode
Number of Preselected Patterns

Control Input Signal


Control Output Signal
Data Save
Power Supply
Power Input
Ambient Temperature
Ambient Humidity
Approx. Mass
Note:

to be selected
by DIP switch

5 s , 20 s, 50 s, 100 s (The settings are DIP switch selectable)

Setting Resolution

Stop Mode
Applicable Only for
Control Mode 1

ON

: The stop mode is to retain the state of controller output at the instant an external input signal is
interrupted. When the external signal is input again, the operation is resumed from the retained state.
OFF : When external input signal is interrupted, function goes back to the initial setting (Pattern No.0).
Current input type, 10 mA /bit max.
Usable as a voltage input type (voltage range: 8 to 48V DC) Photocoupler insulation input
Output from transister open collector
Max. 30V, 50 mA
EEP-ROM (Battery not needed)
100/200 V AC, 50/60 Hz (85-260 V AC)
Less than 10 VA
0-50C (32-122F)
Less than 85%RH (Bedewing must be avoided)
1 kg (2.2 lbs.)

Indicates preset conditions.

Instructions
Since this controller incorporates a micro computer, do subject it to undue electrical noise.

No.20

to be selected
by DIP switch

Setting Adjusters
Multifunction Slope Controllers

PROPORTIONAL
CONTROLS

Control Modes / Setting Example / Slope Type


Control Modes

Setting Example

One among the following 3 types of control modes


can be chosen by changing DIP swicth.

Control Mode 1

Control Mode 1
Channels A and B generate optional slopes
independently each other.
Channel-A
Code Input
Pattern No.

0000

0001

0010

0011

0000

A Channel

Code Input

Pattern Setting %
No. Level Slope

Remarks

A8

A4

A2

A1

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

99.9

40.0

Cylinder forward
acceleration

OFF

OFF

ON

OFF

-80.0

60.0

Cylinder backward
acceleration

OFF

OFF

ON

ON

10.0

50.0

Cylinder forward
deceleration

ON

ON

ON

ON

15

10.0

10.0

Stop

Output
Channel-B
Code Input

0000

0101

0100

0000

Pattern No.

Backward

Forward

Output
Pattern 3

Pattern 1
{
Level
99.9%

Output

Control Mode 2
A slope is generated by a strobe signal (signal for
change to next signal). Channels A and B operate
synchronously.

Pattern 2

Level

Slope Level
50.0% 10.0%

Slope
40.0%

-80.0%

|
0000 0001

0010

0011

0000

Slope
Code Input

Code Input
Strobe Signal
Pattern No.

60.0%

ON
A1

ON

ON

A2

Channel-A
Output

Slope Type
One among the following 4 types can be chosen by changing
DIP switch.

Channel-B
Output

Type 1
(%)
100

Straight
Slope Waveform

50

Channel-A

1.0

1.1

1.2

1.3

Output

Output

3.0 3.1

3.2 3.3 3.4 3.5 3.6 3.7 3.8

3.9

Type 3

Type 4
(%)
100

50
R
0

25

The 0 to 25% and


75 to 100% portions
of the slope
waveform are
rounded with arcs.
Time

Two portions above


and below 50% of
the waveform are
rounded with arcs.
Time

Output Voltage

Pattern No.

Output Voltage

Start Signal 3

50

Time

(%)
100

Channel-B

75

Start Signal 1
Pattern No.

Output Voltage

Output Voltage

Control Mode 3
The internal timer is activated by a start signal,
causing the slopes to be generated successively in
memory.
Channels A and B operate independently.

Type 2

(%)
100

R
50
30
0

Two portions above


and below 30% of
the waveform are
rounded with arcs.
Time

No.21

Setting Adjusters
Multifunction Slope Controllers

PROPORTIONAL
CONTROLS

Installation Drawing
AMC-T

[Example Diagram]
AMC-T-20

(Ex.)
EHDFG-03

Sequence Controller
A1

A2

A4

A8

B1

B2

9
10

B8

11

D/A

IN

D/A

DC24V

EHDFG-03
B

RAM
a
FG

20

IN

19

DC
Power
Supply

COM 12

CO.A 13

3 B out

18

Isolation
Power
Supply

IN

ROM

1 A out
2 COM

IN
B4

CPU

AC
85-260V

C
DC24V

Voc

CO.B 14
M.SV 15

OUT

ALM. 16
17
DOC

DIMENSIONS IN
MILLIMETRES (INCHES)

DC Power
Supply

Terminal Board
Name
A out
COM
B out
A1
A2
A4
A8
B1
B2
B4

Channel A Output
Common
Channel B Output
Code Input
Code Input
Code Input
Code Input
Code Input
Code Input
Code Input

Terminal
Number
11
12
13
14
15
16
17
18
19
20

Name

D : Slope Display
M: Channel B Output

1
2
3
4
5
6
7
8
9
10
11
12
13
POWER
14
ON
15
16
OFF
17 18 19 20

A
B

AMC-T

199(7.83)

189(7.44)

Indicator Lamp
D : Time Display
DIP switch
D : Alteration of Level
Slope Time Values

Panel Operating Key


Data Set (D)
Monitor (M)
70
(2.76)
80
(3.15)

No.22

AC

Power Supply

D : Level Display
M: Channel A Output

Pattern No.
Display

D : Channel
Selection

B8
DCOM
CO.A
CO.B
M.SV
ALM.
DOC
FG

Code Input
Code Input Common
Coincidental Output Signal with "A"
Coincidental Output Signal with "B"
Data Save Signal
Alarm Signal Output
Output Common
Ground

D : Pattern No.
Designation After
Channel Selection

4.5(.18) Dia. Through


4 Places

25
(.98)

60
(2.36)
72
(2.83)

178(7.01)

Terminal
Number
1
2
3
4
5
6
7
8
9
10

Terminal Board
(Refer to table above)

Supply
Switch

Setting Adjusters
Multifunction Slope Controllers
Interchangeability between Current and New Design

PROPORTIONAL
CONTROLS

Interchangeability between Current and New Design


Specifications
Specifications unchanged unless specified below.
Model No.

New : AMC-T-20

Current : AMC-T-10

Output from transister open collector


Max. 30 V, 50 mA

Output from transister open collector


Max. 30 V, 10 mA

Description
Control Output Signal

: 1 Type
4 Types Polygonal Line Signal
Curve Compensation Signal : 3 Types

Slope Types

to be selected
by DIP switch

1 Type : Polygonal Line Signal

Stop Mode
(Applicable only for Control Mode 1)

ON, OFF

Data Save

EEP-ROM Battery not needed

Battery Required

Approx. Mass

1 kg (2.2 lbs.)

1.8 kg (4.0 lbs.)

Terminal
The following are differences between current and new.
Name

Terminal
Number

New : Design 20

Current : Design 10

13

Coincidental Output Signal with "A"


"CO.A"

Coincidental Output Signal with "A"


"DO1"

14

Coincidental Output Signal with "B"


"CO.B"

Coincidental Output Signal with "B"


"DO2"

15

Data Save Signal


"M.SV"

16

Alarm Signal Output


"ALM."

Remarks

Abbreviation of the terminals are changed,


though functionally the same.

Added new functions.

Interchangeability in Installation
There is an interchangeability in installation, although depths (dimensions "A" and "B") are different.

Model Numbers
1
2
3
4
5
6
7
8
9
10
11
12
13
POWER
14
ON
15
16
OFF
17 18 19 20

A
B

AMC-T

mm (Inches)
A

Current

AMC-T-10

185
(7.28)

200
(7.87)

New

AMC-T-20

60
(2.36)

72
(2.83)

A
B