Attenuation ratio:
Switchable:
Bandwidth:
Rise time :
Input impedance:
Max. Voltage:
LF compensation:
RF compensation:
Cable length:
Measuring category:
1:1
10:1
10/100MHz
<35/3.5ns
1/10M II 82/12pF
(10:1) 600V (DC + peak AC)
1 Trimmer at 10:1
2 Trimmer at 10:1
1.2m
CAT I
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Voltage:
LF compensation:
RF compensation:
Cable length:
Probe factor identification:
Measuring category:
10:1
500MHz
<700ps
10M II 9.5pF
400V (DC + peak AC)
1 Trimmer
2 Trimmer
1.3m
automatically after connection
CAT I
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Voltage:
LF compensation:
RF compensation:
Cable length:
Probe factor identification:
Measuring category:
10:1
350MHz
<1.0ns
10M II 12pF
400V (DC + peak AC)
1 Trimmer
2 Trimmer
1.2m
automatically after connection
CAT I
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Voltage:
LF compensation:
RF compensation:
Cable length:
Measuring category:
10:1
150MHz
<2.4ns
10M II 12pF
600V (DC + peak AC)
1 Trimmer
1 Trimmer
1.2m
CAT I
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Voltage:
LF compensation:
RF compensation:
Cable length:
Measuring category:
10:1
250MHz
<1.4ns
10M II 10pF
600V (DC + peak AC)
1 Trimmer
2 Trimmer
1.2m
CAT I
100:1
100MHz
<3.5ns
100M II 4.5pF
1,200V (DC + peak AC)
1 Trimmer
1.2m
CAT I
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Voltage:
LF compensation:
RF compensation:
Cable length:
Probe factor identification:
Measuring category:
1,000:1
400MHz
<900ps
50M II 7.5pF
1,000Vrms
1 Trimmer
1 Trimmer
1.3m
automatically after connection
CAT II
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Input Voltage:
Input Dynamic Range:
Cable length:
Oscilloscope Input Coupling:
External Power Supply
10:1
1GHz
600ps
1M II 0.9pF
20V
8V
1.3m
50
included
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Voltage:
LF compensation:
RF compensation:
Cable length:
Probe factor identification:
Measuring category:
10:1
250MHz
<1.4ns
10M II 15pF
400V (DC + peak AC)
1 Trimmer
2 Trimmers
1.2m
automatically after connection
CAT I
H Z O 2 0 P r o b e 1,0 0 0 : 1
H Z 1 1 5 D i f f e r e n t i a l P r o b e 1 0 0 : 1 / 1,0 0 0 : 1
3,5V/35V
100Vrms
1:1
10:1
30/40MHz
12/9ns
8M II 1.2pF
50
3.5V at 1M
<8mVrms
<2mVrms
3% (1830C)
70dB/>50dB
2 safety connectors
2 test leads 50cm
with spring hooks
9V battery 6LR61
1214Vdc/30mA
700V
600Vrms
20:1
200:1
30/40MHz
12/9ns
8M II 1.2pF
50
3.5V at 1M
2mV
3% (1830C)
70dB/>50dB
2 safety connectors
2 test leads 50cm
with spring hooks
9V battery 6LR61
1214Vdc/30mA
1,000V
1,400V*)
1,400V*)
100:1
1,000:1
20/30MHz
17/12ns
60M II 1.5pF
50
1.5V at 1M
2mV
3% (1830C)
70dB/>50dB
2 safety connectors
2 test leads 75cm
with safety test clips
9V battery 6LR61
1214Vdc/30mA
Bandwidth:
Attenuation ratio:
Rise time (1090%):
Gain accuracy:
Max. Input Voltage per Input:
Max. Differential Input
Voltage (DC + peak AC):
Max. Common Mode
Input Voltage:
Input impedance
Between Inputs:
Each Input to Ground:
Output Voltage (into 50):
Offset (typical):
CMRR (typical):
Battery operation:
Battery life (typical):
Input for an external
power supply:
20V
60V
1M II 3.5pF
500k II 7pF
2V
2mV
-80dB at 60Hz
-50dB at 10MHz
9V battery 6LR61
7.5h
USB Power adapter cable
(59Vdc/200mA)
Bandwidth:
Attenuation ratio:
Rise time (1090%):
Gain accuracy:
Max. Input Voltage per Input:
Max. Differential Input
Voltage (DC + peak AC):
Max. Common Mode
Input Voltage:
Input impedance
Between Inputs:
Each Input to Ground:
Output Voltage (into 50):
Offset (typical):
CMRR (typical):
Battery operation:
Battery life (typical):
Input for an external
power supply:
200MHz
10:1
1.75ns
1%
60V
800MHz
10:1
437ps
2%
40V
15V
30V
200k II 1pF
100k II 2pF
1.5V
5mV
-60dB at 60Hz
-15dB at 500MHz
9V battery 6LR61
4.5h
USB Power adapter cable
(59Vdc/300mA)
Probes_E/100912 C&E Subject to change without notice HAMEG Instruments GmbH DQS-certified in accordance with DIN EN ISO 9001:2008, Reg.-No.: 071040 QM08
HAMEG Instruments GmbH Industriestr. 6 D-63533 Mainhausen Tel +49(0)61828000 Fax +49(0)6182800100 www.hameg.com info@hameg.com