Professional Documents
Culture Documents
micromaster
MICROMASTER 410/420/430/440
Inverters
0.12 kW to 250 kW
Related catalogs
SINAMICS G110
D 11.1
Converter Chassis Units
0.12 kW (0.16 HP) to
3 kW (4 HP)
Order No.:
German: E86060-K5511-A111-A2
English: E86060-K5511-A111-A2-7600
SINAMICS G130
D 11
Converter Chassis Units
SINAMICS G150
Converter Cabinet Units
Order No.:
German: E86060-K5511-A101-A3
English: E86060-K5511-A101-A3-7600
MICROMASTER/COMBIMASTER
DA 51.3
MICROMASTER 411 Inverters
Distributed Drive Solutions
COMBIMASTER 411
Order No.:
German: E86060-K5251-A131-A2
English: E86060-K5251-A131-A2-7600
Industrial Communication
for Automation and Drives
Part 6: Distributed I/Os ET 200
Frequency Converter ET 200S FC
Order No.:
E86060-K6710-A101-B4-7600
IK PI
Low-Voltage Motors
M 11
Order No.:
German: E86060-K1711-A101-A3
English: E86060-K1711-A101-A3-7600
Geared Motors
Helical, Flat, Bevel-helical,
Helical-worm
and Worm Geared Motors
Order No.:
E86060-K1715-A101-A5
(available in German only)
M 15
Catalog CA 01
CA 01
The Offline Mall of Automation and Drives
Order No.:
CD-ROM: E86060-D4001-A100-C4 (Germ.)
CD-ROM: E86060-D4001-A110-C4-7600 (Engl.)
DVD:
E86060-D4001-A500-C4 (Germ.)
A&D Mall
Hotline:
For technical advice and hotline support concerning our CA 01
catalog:
Tel.: +49 (0) 180 50 50 22 2
Internet:
http://www.siemens.com/automation/mall
Trademarks
All product designations may be trademarks or product
names of Siemens AG or supplier companies whose
use by third parties for their own purposes could
violate the rights of the owners.
E-Mail: adsupport@siemens.com
MICROMASTER
410/420/430/440
Inverters
0.12 kW to 250 kW
Catalog DA 51.2
2005/2006
Overview
MICROMASTER 410
The low-priced
Welcome to
Automation and Drives
Selection guide
MICROMASTER inverters
Overview of options
0.12 kW to 0.75 kW
Supersedes:
Catalog DA 51.2 2003/2004
The products in this catalog are also included
in the CD-ROM catalog CA 01.
Order No.:
E86060-D4001-A110-C4-7600 (CD-ROM)
Contact your local Siemens representative
for further information
MICROMASTER 420
The universal
0.12 kW to 11 kW
Siemens AG 2005
MICROMASTER 430
The specialist for
pumps and fans
7.5 kW to 250 kW
3
The products and systems described in this
catalog are manufactured/distributed under
application of a certified
quality management
system in accordance
with DIN EN ISO 9001
(Certified Registration
No. 000357 QM) and
DIN EN ISO 14001
(Certified Registration
No. 081342 UM and
EMS 57390). The certificate is recognized by
all IQNet countries.
MICROMASTER 440
The all-purpose
Appendix
0.12 kW to 250 kW
Certificates/Standards
Demonstration case/
Training
Overview of motors and
inverters
Siemens contacts
Online services
Service & Support
Conditions of sale and
delivery
Export regulations
Sprachumschaltung ber
Spezial - Bedingter Text Ein-/Ausblenden
Welcome to
Automation and Drives
0/2
0/3
Sprachumschaltung ber
Spezial - Bedingter Text Ein-/Ausblenden
Welcome to
Automation and Drives
0/2
0/3
and production areas to shipping. Thanks to the systemoriented engineering environment, integrated, open communications as well as intelligent diagnostics options, your plant
now benefits in every phase of the life cycle.
In fact, to this day we are the only company worldwide that can
offer a control system based on an integrated platform for both
the production and process industry.
ERP
Enterprise
Resource
Planning
MES
Manufacturing
Execution
Systems
Control
SIMATIC NET
Industrial
Communication
Ethernet
Production
Order
Management
Material
Management
Production
Operations
Recording
SINAUT Telecontrol
System
Equipment
Management
Production Modeler
Detailed
Production
Scheduling
Laboratory Information
Management System
SIMATIC
Software
SIMATIC
Controller/
Automation
System
Ethernet
Industrial
Ethernet
Product Specification
Management System
SIMATIC IT Framework
Ethernet
SIMATIC
Machine Vision
Industrial
Plant
Information
Management
Industrial Wireless
Communication/
MOBIC
Safety Integrated
SENTRON
CircuitBreakers
SIMATIC
Distributed
I/O
SINUMERIK
Numeric
Control
SIMOTION
Motion Control
System
SIMODRIVE
SINAMICS
SIMATIC HMI
Human Machine
Interface
SIMATIC PCS 7
Process Control
System
PROCESS FIELD
Process
Instrumentation and
Analytics
PROFIBUS
PC-based Automation
AS-Interface
GAMMA instabus
0/4
Building
Technology
Micro-Automation
and
Actuator-Sensor
Interface Level
Sensor
Technology
IQ-Sense
ECOFAST IP65
Distributed
Automation System
SIMOCODE pro
Motor Management System
HART
SIWAREX
Weighing
Technology
PROFIBUS PA
Drive Systems/
SINAMICS
0/5
and production areas to shipping. Thanks to the systemoriented engineering environment, integrated, open communications as well as intelligent diagnostics options, your plant
now benefits in every phase of the life cycle.
In fact, to this day we are the only company worldwide that can
offer a control system based on an integrated platform for both
the production and process industry.
ERP
Enterprise
Resource
Planning
MES
Manufacturing
Execution
Systems
Control
SIMATIC NET
Industrial
Communication
Ethernet
Production
Order
Management
Material
Management
Production
Operations
Recording
SINAUT Telecontrol
System
Equipment
Management
Production Modeler
Detailed
Production
Scheduling
Laboratory Information
Management System
SIMATIC
Software
SIMATIC
Controller/
Automation
System
Ethernet
Industrial
Ethernet
Product Specification
Management System
SIMATIC IT Framework
Ethernet
SIMATIC
Machine Vision
Industrial
Plant
Information
Management
Industrial Wireless
Communication/
MOBIC
Safety Integrated
SENTRON
CircuitBreakers
SIMATIC
Distributed
I/O
SINUMERIK
Numeric
Control
SIMOTION
Motion Control
System
SIMODRIVE
SINAMICS
SIMATIC HMI
Human Machine
Interface
SIMATIC PCS 7
Process Control
System
PROCESS FIELD
Process
Instrumentation and
Analytics
PROFIBUS
PC-based Automation
AS-Interface
GAMMA instabus
0/4
Building
Technology
Micro-Automation
and
Actuator-Sensor
Interface Level
Sensor
Technology
IQ-Sense
ECOFAST IP65
Distributed
Automation System
SIMOCODE pro
Motor Management System
HART
SIWAREX
Weighing
Technology
PROFIBUS PA
Drive Systems/
SINAMICS
0/5
410/420/430/440
MICROMASTER410/420/430/440
Overview
Selection guide
MICROMASTER 410
MICROMASTER 420
The low-priced
The universal
Power ranges
0.12 kW to 0.75 kW
0.12 kW to 11 kW
Voltage ranges
1 AC 100 V to 120 V
1 AC 200 V to 240 V
1 AC 200 V to 240 V
3 AC 200 V to 240 V
3 AC 380 V to 480 V
Control methods
V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
FCC (flux current control)
V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
FCC (flux current control)
Process control
Internal PI controller
Inputs
3 digital inputs
1 analog input
3 digital inputs
1 analog input
Outputs
1 relay output
1 analog output
1 relay output
Interfacing to automation
system
Additional features
BICO technology
Compound braking for controlled rapid braking
Section 1
Section 2
Main characteristics
0/6
MICROMASTER 410/420/430/440
Overview
MICROMASTER 430
MICROMASTER 440
The all-purpose
7.5 kW to 250 kW
0.12 kW to 250 kW
3 AC 380 V to 480 V
1 AC 200 V to 240 V
3 AC 200 V to 240 V
3 AC 380 V to 480 V
3 AC 500 V to 600 V
V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
FCC (flux current control)
V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
FCC (flux current control)
Vector control
6 digital inputs
2 analog inputs
1 PTC/KTY input
6 digital inputs
2 analog inputs
1 PTC/KTY input
2 analog outputs
3 relay outputs
2 analog outputs
3 relay outputs
Low-energy mode
Load torque monitoring
(detects dry run of pumps)
Motor staging
Bypass mode
BICO technology
Section 3
Section 4
0/7
MICROMASTER 410/420/430/440
Overview
Options
Various options are available
for the MICROMASTER
inverters:
Filters
Chokes
Operator panels
PROFIBUS module
DeviceNet module
CANopen module
Pulse encoder evaluation
module
Gland plates
Mounting kits, etc.
Order No.
410
MICROMASTER
420
430
440
Operator panels
OP
BOP
BOP-2
AOP
AAOP
6SE6400-0SP00-0AA0
6SE6400-0BP00-0AA0
6SE6400-0BE00-0AA0
6SE6400-0AP00-0AA1
6SE6400-0AP00-0AB0
%
%
%
%
%
%
Modules
PROFIBUS
DeviceNet
CANopen
Pulse encoder evaluation
6SE6400-1PB00-0AA0
6SE6400-1DN00-0AA0
6SE6400-1CB00-0AA0
6SE6400-0EN00-0AA0
%
%
%
%
%
%
%
% Possible combination
OP/BOP
BOP-2
AOP
AAOP
DeviceNet
CANopen
Operator panels
PROFIBUS
Modules
0/8
%
%
%
%
Inverter
MICROMASTER 410
1/2
Description
1/4
Circuit diagrams
1/6
Technical data
1/7
1/8
Options
1/10
Dimension drawings
1/1
MICROMASTER 410
Description
Inverter
Frame size AB
Inverter
Frame size AA
Application
The MICROMASTER 410 inverter is suitable for a variety
of variable-speed drive applications.
It is especially suitable for use
with pumps and fans, as a
drive in various sectors, e.g.
food, textile and packaging industries as well as for conveyor systems, factory gate and
garage door drives and as a
universal drive for moving billboards.
It is the ideal low-cost frequency inverter solution for the lowend performance range of the
MICROMASTER product family.
Design
The MICROMASTER 410 inverter has a compact design.
Heatsinks provide natural
cooling for the inverter. A fan
unit is not used.
The position of the connections has been selected as for
conventional contactors.
The operator panel available
as an option can be easily fitted without requiring any tools.
The design with flat plate heatsink offers space-saving and
favorable heat dissipation
since an additional heatsink
can be installed outside the
control cabinet.
Inverter
with flat heat sink
Main characteristics
Simple selection from mini-
1/2
Options (overview)
mounting on DIN rails
OP (Operator Panel) for
International standards
The MICROMASTER 410
c-tick
Note:
See Appendix for standards.
MICROMASTER 410
Description
Mechanical features
Performance features
Compact design
Digital microprocessor
self-ventilation (convection)
Operating temperature
10 C to +50 C
(+14 F to +122 F)
Easy cable connection,
mains and motor connections are separated for optimal electromagnetic compatibility and clear
connection
Detachable, optional operator panels
Screwless control terminals
Side mounting possible,
thus also usable with low
cabinet depth.
control
Linear V/f characteristic,
with programmable voltage
boosting
Quadratic V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
Flying restart
Automatic restart after
mains failure or fault
Programmable ramp generator (0 s to 650 s) with possible rounding
Fast current limit (FCL) for
trip-free operation
Protection features
Fast, repeatable digital in
1/3
MICROMASTER 410
Circuit diagrams
1 0 0 V to 1 2 0 V 1 A C
2 0 0 V to 2 4 0 V 1 A C
P E
F S 1
V o lta g e s u p p ly a n d a n a lo g in p u t
In p u t v o lta g e : 0 V to + 1 0 V ,
s c a la b le
6
-> 4 . 7 k
+ 1 0 V
A
A IN +
7
8
D IN 2
D IN 3
A C
D C
2 4 V
0 V
m a x . 3 3 V
m a x . 5 m A
1
D IN 1
+ 2 4 V (m a x . 5 0 m A )
5
0 V
tp u t re
0 V A C
d u c tiv e
V D C ,
s is tiv e
la y c o n ta c ts
, m a x . 2 A
lo a d )
m a x . 5 A
lo a d )
R L 1
R L 1 -B
R L 1 -C
P +
N -
D C +
D C -
C P U
V o lta g e s u p p ly
(e x te rn a l o r
in te r n a l s o u r c e )
O u
2 5
( in
3 0
(re
L , N
P E
1 1
D C
1 2
A C
9
1 0
S e r ia l
in te r fa c e
R S -4 8 5
U , V , W
P E
G _ D A 5 1 _ E N _ 0 5 0 3 3 c
3 ~
F o r a n a d d itio n a l d ig ita l in p u t ( D IN 4 ) e x te r n a l
c o n n e c tio n s s h o u ld b e m a d e :
D IN 4
+
-
7
4
2 4 V
5
V o lta g e s u p p ly
(e x te rn a l o r
in te r n a l
s o u rc e )
G _ D A 5 1 _ E N _ 0 5 0 3 4 b
1/4
MICROMASTER 410
Circuit diagrams
View A
Motor connections
A DA51-5035a
View A
Output relay
RL1
RL1-B
RL1-C
11
12
DIN1
1
DIN2
DIN3
+24V
0V
+10V
AIN+
0V
P+
N-
10
RS-485
(USS protocol)
Digital inputs
Voltage
supply 24 V
Analog input
Voltage
supply 10 V
1/5
MICROMASTER 410
Technical data
Precharge current
Control method
Pulse frequency
Fixed frequencies
Skip frequency ranges
Setpoint resolution
Digital inputs
Analog input
Relay outputs
Serial interface
Motor cable lengths
Electromagnetic compatibility
Braking
Degree of protection
Operating temperature
Storage temperature
Relative humidity
Site altitude
Protection features for
Typical power losses (heatsink) at
full load and maximum operating
temperature as specified
Line-side and control electronics
losses (at 230 V, 50 Hz, 8 kHz)
Recommended thermal resistance
of heatsink
Compliance with standards
> marking
Dimensions and weights (without
options)
1 AC 200 V to 240 V 10 %
0.12 to 0.75 kW
1 AC 100 V to 120 V 10 %
0.12 to 0.55 kW
47 to 63 Hz
0 Hz to 650 Hz
0.95
90 % to 95 %
Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 60 s;
then 0.85 x rated output current for 240 s, cycle time 300 s
Not higher than rated input current
Linear V/f characteristic; quadratic V/f characteristic; multipoint characteristic
(programmable V/f characteristic)
8 kHz (standard)/2 kHz to 16 kHz (in 2 kHz steps)
3, programmable
1, programmable
10 bit analog/0.01 Hz serial
3 programmable digital inputs, non-floating, PNP, SIMATIC-compatible
1, for setpoint (0 V to 10 V, scaleable or for use as 4th digital input)
1, programmable, 30 V DC/5 A (resistive load); 250 V AC/2A (inductive load)
RS-485, for operation with USS protocol
Max. 30 m (shielded)/max. 50 m (unshielded)
Inverter available with internal EMC filter to EN 61 800-3 (defined limits to EN 55 011, Class B)
DC braking, compound braking
IP20
10 C to +50 C (+14 F to +122 F)
40 C to +70 C (40 F to +158 F)
95 % (non-condensing)
Up to 1000 m above sea level without derating
Undervoltage, overvoltage, overload, earth faults, short circuits, stall prevention,
I2t motor thermal protection, inverter overtemperature
20 W (with 0.37 kW inverter with flat plate heatsink)
37 W (with 0.75 kW inverter with flat plate heatsink)
18 W (with 0.37 kW inverter with flat plate heatsink)
34 W (with 0.75 kW inverter with flat plate heatsink)
1.8 K/W (with 0.37 kW inverter with flat plate heatsink)
1.2 K/W (with 0.75 kW inverter with flat plate heatsink)
u, cu (not for versions with flat plate heatsink)
>, c-tick
Conformity with low-voltage directive 73/23/EC
Frame size (FS)
H x W x D (mm)
AA
150 x 69 x 118
AB
150 x 69 x 138
0.37 kW inverter with flat plate heatsink
175 x 69 x 102
0.75 kW inverter with flat plate heatsink
175 x 69 x 102
14 kHz
0.6
1.1
1.5
2.3
2.0
2.3
2.6
3.0
Derating data
Pulse frequency
Output
kW
0.12
0.25
0.37
0.55
0.55, 115 V (at 50 C/122 F)
0.55, 115 V (at 40 C/104 F)
0.75 (at 50 C/122 F)
0.75 (at 40 C/104 F)
8 kHz
0.9
1.7
2.3
3.2
2.7
3.2
3.6
4.2
10 kHz
0.8
1.5
2.0
2.9
2.5
2.9
3.2
3.8
The current data apply to an ambient temperature of 50 C/122 F unless specified otherwise.
1/6
12 kHz
0.7
1.3
1.7
2.6
2.2
2.6
2.9
3.4
16 kHz
0.5
0.9
1.3
2.0
1.7
2.0
2.3
2.7
MICROMASTER 410
Technical data
ADA51-5039a
ADA51-5038a
100
%
80
75
60
Mains voltage
100
90
80
%
60
40
40
20
20
1000
2000
3000 m 4000
Operational altitude
1
0
1000
2000
3000 m 4000
Operational altitude
kW
hp
Rated input
current 1)
Frame
size
(FS)
Order No.
MICROMASTER 410
without filter 2)
MICROMASTER 410
with internal filter Class B
0.16
0.33
0.50
0.75
4.6
7.5
10.1
13.4
0.9
1.7
2.3
2.7 (3.2 at 40 C/104 F)
AA
AA
AA
AB
6SE6410-2UA11-2AA0
6SE6410-2UA12-5AA0
6SE6410-2UA13-7AA0
6SE6410-2UA15-5BA0
0.9
1.7
2.3
3.2
3.6 (4.2 at 40 C/104 F)
AA
AA
AA
AB
AB
6SE6410-2UB11-2AA0
6SE6410-2UB12-5AA0
6SE6410-2UB13-7AA0
6SE6410-2UB15-5BA0
6SE6410-2UB17-5BA0
6SE6410-2BB11-2AA0
6SE6410-2BB12-5AA0
6SE6410-2BB13-7AA0
6SE6410-2BB15-5BA0
6SE6410-2BB17-5BA0
2.3
4.2 (at 40 C/104 F)
AA
AB
6SE6410-2UB13-7AB0
6SE6410-2UB17-5BB0
6SE6410-2BB13-7AB0
6SE6410-2BB17-5BB0
Motors for
MICROMASTER 410
Catalog M 11 contains selection and ordering data for motors which are particularly suitable for operation with the
MICROMASTER 410 inverters
(see Appendix for overview).
This catalog is suitable for IEC
motors. For motors according
to US standards (NEMA)
please refer to:
http://www.sea.siemens.com/
motors
Siemens DA 51.2 2005/2006
1/7
MICROMASTER 410
Options
Inverter dependent options
Overview
EMC filter, Class B
Variants with internal EMC filter Class B are available for inverters with a mains operating
voltage of 1 230 V AC.
Mains
voltage
Output
kW
The inverter and the associated options have the same voltage ratings.
Inverter
without filter
Line commutating
choke
0.16
6SE6410-2UA11-2AA0
0.33
6SE6410-2UA12-5AA0
0.37
0.50
6SE6410-2UA13-7AA0 *)
0.55
0.75
6SE6410-2UA15-5BA0 *)
1 AC 200 V 0.12
to 240 V
0.25
0.16
6SE6410-2UB11-2AA0
6SE6400-2FL01-0AB0
0.33
6SE6410-2UB12-5AA0
0.37
0.50
6SE6410-2UB13-7AA0
0.55
0.75
6SE6410-2UB15-5BA0
0.75
1.0
6SE6410-2UB17-5BA0
0.75
6SE6400-3CC01-0AB3
Fuse
(see Catalog
LV 10)
3NA3803
Circuit-breaker
(see Catalog
LV 10)
3RV1021-1GA10
6SE6400-3CC02-6BB3
3NA3805
3RV1021-1KA10
3NA3807
3RV1021-4AA10
3NA3803
3RV1021-1BA10
hp
1 AC 100 V 0.12
to 120 V
0.25
6SE6400-3CC00-4AB3
3RV1021-1EA10
3RV1021-1FA10
3RV1021-1HA10
6SE6400-2FL01-0AB0
6SE6410-2UB17-5BB0 *)
1 AC 200 V 0.12
to 240 V
0.25
0.16
0.33
6SE6410-2BB12-5AA0
0.37
0.50
6SE6410-2BB13-7AA0
0.55
0.75
6SE6410-2BB15-5BA0
0.75
1.0
6SE6410-2BB17-5BA0
0.75
6SE6410-2BB17-5BB0 *)
3RV1021-1JA10
6SE6400-3CC01-0AB3
1.0
1.0
6SE6400-3CC01-0AB3
6SE6400-3CC00-4AB3
3NA3805
3RV1021-1JA10
3NA3803
3RV1021-1FA10
3NA3805
3RV1021-1JA10
3NA3803
3RV1021-1BA10
3RV1021-1EA10
6SE6400-3CC01-0AB3
3RV1021-1FA10
3RV1021-1HA10
6SE6400-3CC01-0AB3
3NA3805
3RV1021-1JA10
3NA3803
3RV1021-1FA10
3NA3805
3RV1021-1JA10
*) With these inverters, the filter or choke cannot be mounted in the substructure. This option must be mounted upright.
1/8
MICROMASTER 410
Options
Variant independent options
Overview
Operator Panel (OP)
Start-up tools
STARTER
is a graphic start-up software for guided start-up for
MICROMASTER 410/420/
430/440 frequency inverters
under Windows NT/2000/
XP Professional. Parameter
lists can be read out, altered, stored, entered and
printed.
DriveMonitor
is a start-up software for listoriented programming of
frequency inverters. This
program executes under
Windows 98/NT/2000/ME/
XP Professional.
Order No.
6SE6400-0SP00-0AA0
6SE6400-0PL00-0AA0
6SE6400-0DR00-0AA0
6SE6400-5EA00-1AG0
6SL3072-0AA00-0AG0
Documentation
Parameter list 1)
(paper version)
Language
German
English
French
Italian
Spanish
German
English
French
Italian
Spanish
Multilanguage
Order No.
6SE6400-5EA00-0AP0
6SE6400-5EA00-0BP0
6SE6400-5EA00-0DP0
6SE6400-5EA00-0CP0
6SE6400-5EA00-0EP0
6SE6400-5EB00-0AP0
6SE6400-5EB00-0BP0
6SE6400-5EB00-0DP0
6SE6400-5EB00-0CP0
6SE6400-5EB00-0EP0
STARTER at
http://www4.ad.siemens.de/
WW/view/com/10804985/
133100
1/9
MICROMASTER 410
Dimension drawings
12
(0.47)
163 (6.44)
175 (6.89)
160 (6.30)
69
(2.72)
(4 102
.0
2)
69
(2.72)
69
(2.72)
4.5
(0.18)
34.5
(1.36)
G_DA51_EN_05073
(4 118
.6
5)
(5 138
.4
3)
4.5
(0.18)
150 (5.9)
150 (5.9)
160 (6.30)
A DA51-5036a
4.5
(0.18)
ADA51-5037a
12
(0.47)
42.5 (1.67)
Footprint chokes
6SE6400-3CC00-4AB3
6SE6400-3CC01-0AB3
150
(5.91)
G_DA51_EN_05105a
50
(1.97)
75.5
(2.97)
213 (8.39)
50
(1.97)
G_DA51_EN_05104a
ADA51-5010e
200 (7.87)
160 (6.3)
2 x M4
(2.87)
(2.2)
200 (7.87)
73
56
174 (6.85)
187 (7.36)
23.5
(0.93)
Filter
6SE6400-2FL01-0AB0
1/10
Inverter
MICROMASTER 420
2/2
Description
2/4
Circuit diagrams
2/6
Technical data
2/8
2/9
Options
2/18
Dimension drawings
2/1
MICROMASTER 420
Description
2
Applications
The MICROMASTER 420 inverter is suitable for a variety
of variable-speed drive applications. It is especially suitable for applications with
pumps, fans and in conveyor
systems.
It is the ideal cost-optimized
frequency inverter solution.
The inverter is especially characterized by its customer-oriented performance and easeof-use. Its large mains voltage
range enables it to be used all
over the world.
Main characteristics
LC filter
c-tick
2/2
International standards
Design
Options (overview)
Note:
See Appendix for standards.
MICROMASTER 420
Description
Mechanical features
Performance features
Modular design
Operating temperature
Digital microprocessor
10 C to +50 C
(+14 F to +122 F)
Compact housing as a result of high power density
Easy cable connection,
mains and motor connections are separated for optimum electromagnetic compatibility
Detachable operator
panels
Screwless control terminals
control
Flux Current Control (FCC)
for improved dynamic response and optimized motor control
Linear V/f characteristic
Quadratic V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
Flying restart
Slip compensation
Automatic restart following
mains failure or fault
Internal PI controller for simple process control
Protection features
Programmable accelera-
tion/deceleration times
from 0 s to 650 s
Ramp smoothing
Fast Current Limit (FCL) for
trip-free operation
Fast, repeatable digital input response time
Fine adjustment using a
high-resolution 10-bit analog input
Compound braking for controlled rapid braking
Four skip frequencies
Removable Y capacitor
for use on IT systems (with
non-grounded mains supplies, the Y capacitor
must be removed and an
output choke installed).
2/3
MICROMASTER 420
Circuit diagrams
PE
1/3 AC 200 - 240 V
3 AC 380 - 480 V
SI
2
4,7 k
3
PE
+10 V
0V
ADC+
A
ADC-
BOP link
RS232
24 V external
150.00
DIN1
DIN2
DIN3
L/L1, N/L2
or
L/L1, N/L2, L3
or
L1, L2, L3
DIN1
5
BOP/AOP
DIN2
DIN3
7
7
+
_ 24 V
=
Output +24 V
max. 100 mA
(isolated)
PNP
8
or
NPN
DC+
DC link
Output 0 V
max. 100 mA
(isolated)
DC
CPU
RL1-B
30 V DC/5 A (resistive load)
Relay 10 RL1-C
250 V AC/2 A (inductive load)
11
12
DAC-
3~
13
P+
14
N-
60 Hz
Not
used
RS485
COM link
50 Hz
1
DIP switch
15
PE
CB
option
3
4
24 V
2/4
U,V,W
automatic
M
G_DA51_EN_00011
DAC+
0 - 20 mA
max. 500
MICROMASTER 420
Circuit diagrams
View A
DC link
terminals
Mains
connections
Motor
connections
View A
DAC+
DAC-
P+
N-
12
13
14
15
G_DA51_EN_05106
Output relay
RL1
RS-485
(USS protocol)
Analog output
DIN1
DIN2
DIN3
+24 V
0 V (isolated)
PNP
RL1-B
10
RL1-C
11
NPN
Output relay contacts
Digital inputs
PNP or NPN
possible
+10 V
0V
ADC+
ADC-
Voltage
supply 10 V
Analog input
2/5
MICROMASTER 420
Technical data
Fixed frequencies
Skip frequency ranges
Setpoint resolution
1 AC 200 V to 240 V 10 %
0.12 kW to 3 kW
3 AC 200 V to 240 V 10 %
0.12 kW to 5.5 kW
3 AC 380 V to 480 V 10 %
0.37 kW to 11 kW
47 Hz to 63 Hz
0 Hz to 650 Hz
0.95
96 % to 97 %
Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 60 s, cycle time 300 s
Less than rated input current
Linear V/f-characteristic; quadratic V/f characteristic; multipoint characteristic
(programmable V/f characteristic); flux current control (FCC)
16 kHz (standard with 1/3 AC 230 V)
4 kHz (standard with 3 AC 400 V)
2 kHz to 16 kHz (in 2 kHz steps)
7, programmable
4, programmable
0.01 Hz digital
0.01 Hz serial
10 bit analog
3 fully programmable isolated digital inputs; switchable PNP/NPN
1, for setpoint or PI controller (0 V to 10 V, scaleable or for use as 4th digital input)
1, programmable, 30 V DC/5 A (resistive load); 250 V AC/2A (inductive load)
1, programmable (0 mA to 20 mA)
RS-485, optional RS-232
Digital inputs
Analog input
Relay outputs
Analog output
Serial interfaces
Motor cable lengths
without output choke max. 50 m (shielded)
max. 100 m (unshielded)
without output choke see variant dependent options
Electromagnetic compatibility
Inverter available with internal EMC filter Class A;
available as options are EMC filters to EN 55 011, Class A or Class B
Braking
DC braking, compound braking
Degree of protection
IP20
Operating temperature
10 C to +50 C (+14 F to +122 F)
Storage temperature
40 C to +70 C (40 F to +158 F)
Relative humidity
95 % (non-condensing)
Site altitude
Up to 1000 m above sea level
without derating
Protection features for
Undervoltage
Overvoltage
Overload
Earth faults
Short circuit
Stall prevention
Locked motor protection
Motor overtemperature
Inverter overtemperature
Parameter interlock
2/6
MICROMASTER 420
Technical data
Derating data
PWM frequency
Output
(for 3 AC 400 V)
kW
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11
4 kHz
1.2
1.6
2.1
3.0
4.0
5.9
7.7
10.2
13.2
19.0
26.0
6 kHz
1.2
1.6
2.1
3.0
4.0
5.9
7.7
10.2
13.2
18.4
26.0
8 kHz
1.2
1.6
2.1
2.7
2.7
5.1
5.1
6.7
13.2
13.2
17.9
10 kHz
1.2
1.6
2.1
2.7
2.7
5.1
5.1
6.7
13.2
13.2
17.9
12 kHz
1.2
1.6
1.6
1.6
1.6
3.6
3.6
4.8
9.6
9.6
13.5
14 kHz
1.2
1.6
1.6
1.6
1.6
3.6
3.6
4.8
9.6
9.6
13.5
16 kHz
1.1
1.1
1.1
1.1
1.1
2.6
2.6
3.6
7.5
7.5
10.4
Operating temperature
R a te d o u tp u t c u rre n t
A D A 5 1 -5 0 1 7 e
1 0 0
%
8 0
6 0
5 0
4 0
2 0
0
-1 0
1 0
2 0
3 0
4 0
5 0
6 0 C 7 0
O p e r a tin g te m p e r a tu r e
100
%
80
60
40
20
0
1000
2000
3000 m 4000
Operational altitude
Mains voltage
100
%
80
77
60
40
20
0
1000
2000
3000 m 4000
Operational altitude
2/7
MICROMASTER 420
Selection and ordering data
kW
Rated input
current 1)
hp
Rated output
current
Frame size
Order No.
MICROMASTER 420
without filter 3)
MICROMASTER 420
with internal filter
Class A 2)
A
A
A
A
A
B
B
B
C
6SE6420-2UC11-2AA1
6SE6420-2UC12-5AA1
6SE6420-2UC13-7AA1
6SE6420-2UC15-5AA1
6SE6420-2UC17-5AA1
6SE6420-2UC21-1BA1
6SE6420-2UC21-5BA1
6SE6420-2UC22-2BA1
6SE6420-2UC23-0CA1
6SE6420-2AB11-2AA1
6SE6420-2AB12-5AA1
6SE6420-2AB13-7AA1
6SE6420-2AB15-5AA1
6SE6420-2AB17-5AA1
6SE6420-2AB21-1BA1
6SE6420-2AB21-5BA1
6SE6420-2AB22-2BA1
6SE6420-2AB23-0CA1
A
A
A
A
A
B
B
B
C
C
C
6SE6420-2UC11-2AA1
6SE6420-2UC12-5AA1
6SE6420-2UC13-7AA1
6SE6420-2UC15-5AA1
6SE6420-2UC17-5AA1
6SE6420-2UC21-1BA1
6SE6420-2UC21-5BA1
6SE6420-2UC22-2BA1
6SE6420-2UC23-0CA1
6SE6420-2UC24-0CA1
6SE6420-2UC25-5CA1
6SE6420-2AC23-0CA1
6SE6420-2AC24-0CA1
6SE6420-2AC25-5CA1
A
A
A
A
A
B
B
B
C
C
C
6SE6420-2UD13-7AA1
6SE6420-2UD15-5AA1
6SE6420-2UD17-5AA1
6SE6420-2UD21-1AA1
6SE6420-2UD21-5AA1
6SE6420-2UD22-2BA1
6SE6420-2UD23-0BA1
6SE6420-2UD24-0BA1
6SE6420-2UD25-5CA1
6SE6420-2UD27-5CA1
6SE6420-2UD31-1CA1
6SE6420-2AD22-2BA1
6SE6420-2AD23-0BA1
6SE6420-2AD24-0BA1
6SE6420-2AD25-5CA1
6SE6420-2AD27-5CA1
6SE6420-2AD31-1CA1
(FS)
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
1.8
3.2
4.6
6.2
8.2
11.0
14.4
20.2
35.5
0.9
1.7
2.3
3.0
3.9
5.5
7.4
10.4
13.6
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
1.1
1.9
2.7
3.6
4.7
6.4
8.3
11.7
15.6
19.7
26.5
0.9
1.7
2.3
3.0
3.9
5.5
7.4
10.4
13.6
17.5
22.0
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
10.0
15.0
2.2
2.8
3.7
4.9
5.9
7.5
10.0
12.8
15.6
22.0
32.3
1.2
1.6
2.1
3.0
4.0
5.9
7.7
10.2
13.2
19.0
26.0
1) Supplementary conditions:
Input current at rated operating
point, applicable at shortcircuit voltage of the supply
Usc = 2 % with reference to the
2/8
Motors for
MICROMASTER 420
Catalog M 11 contains selection and ordering data for motors which are particularly suitable for operation with the
MICROMASTER 420 inverters
(see Appendix for overview).
2) Use of MICROMASTER inverters with internal filter is not permissible on non-grounded (IT)
mains supplies.
MICROMASTER 420
Options
Variant dependent options
Overview
EMC filter, Class A
Filter for inverters without an
internal filter for
3 AC 200 V to 240 V,
frame sizes A and B
3 AC 380 V to 480 V,
frame size A.
All other inverters can be supplied with an internal Class A
filter.
The requirements are fulfilled
using shielded cables with a
max. length of 25 m.
Leakage currents:
The leakage currents of the inverters with/without filter (internal/external) may exceed
30 mA. Typical values in practice are between 10 mA and
50 mA. The exact values depend on the design, environment and cable lengths. Interference-free operation with residual current operated devices with a trigger value of
30 mA cannot be guaranteed.
However, operation with residual current circuit-breakers
with a trigger value of 300 mA
is possible. Please refer to the
Instruction Manual for details.
LC filter
The LC filter limits the rate of
rise of voltage and the capacitive charge/discharge currents which usually occur with
inverter operation. This means
that much longer shielded motor cables are possible when
using LC filters and the service life of the motor achieves
values similar to those with
direct mains operation.
Use of an output choke isnt
required with that.
Please note when using
LC filters:
Only V/f, FCC control permissible
Please observe the derating
of 15 % when selecting the
appropriate inverter
Operation only permissible
with 4 kHz pulse frequency
The output frequency is limited to 150 Hz.
The LC filters can be used for
all MICROMASTER 420 inverters of frame sizes A to C.
Line commutating choke
Line commutating chokes
are used to smooth voltage
peaks or to bridge commutating dips. In addition, line commutating chokes reduce the
effects of harmonics on the inverter and the power supply. If
the line impedance is <1 %, a
line commutating choke must
be used in order to reduce the
current peaks.
2/9
MICROMASTER 420
Options
Variant dependent options
Technical data
LC filter
Mains voltage
Current (at 40 C/50 C)
3 AC 380 V to 480 V
for frame size A 4.5 A/ 4.1 A
for frame size B 11.2 A/10.2 A
for frame size C 32.6 A/29.7 A
Limiting of motor overvoltage
1078 V
dV/dt limiting
500 V/ms
Pulse frequency
4 kHz
Max. motor frequency
150 Hz
Max. permissible motor cable
shielded 200 m
lengths
unshielded 300 m
Insulation strength
Overvoltage category III to VDE 0110
Electromagnetic compatibility
Up to 200 m motor cable length with emissions to Class A according to EN 55 011 in
conjunction with filtered inverters and unshielded cables
Conformity
CE according to the low-voltage directive 73/23/EEC
Approvals
UL available soon
Strain resistance
EN 60 068-2-31
Humidity
95 % humidity, non-condensing
Degree of protection
IP20 (to EN 60529)
Insulation class
H (180 C)
Permissible temperature
Operation 10 C to +40 C (+14 F to +104 F) 100 % Pn
to +50 C (to +122 F)
80 % Pn
Storage 25 C to +70 C (13 F to +158 F)
Operational altitude
up to 2000 m 100 % Pn
2000 to 4000 m 62.5 % Pn
Mounting position
Footprint or suspended
Free space
Top 100 mm
Bottom 100 mm
Side 100 mm
Connection system
Input, litz wire or terminal 1U1, 1V1, 1W1
Output, terminals 1U2, 1V2, 1W2
Torque for power conductor connections
1.5 Nm to 1.8 Nm
Weight, approx.
for frame size A 7 kg
for frame size B 11 kg
for frame size C 29 kg
Max. permissible cable lengths from the motor to the inverter when using output chokes
The following table shows the
maximum permissible cable
lengths from the motor to the
inverter when using output
chokes.
Frame size
Output choke
(FS)
A
A
B
C
Type
6SE6400-3TC00-4AD3
6SE6400-3TC00-4AD2
6SE6400-3TC01-0BD3
6SE6400-3TC03-2CD3
2/10
200 m/300 m
150 m/225 m
100 m/150 m
200 m/300 m
150 m/225 m
100 m/150 m
200 m/300 m
200 m/300 m
100 m/150 m
MICROMASTER 420
Options
Variant dependent options
Design
A maximum of two footprint
G_DA51_EN_05016d
Position 2
Position 1
2
Example of installation with frequency inverter,
EMC filter (position 1) and line choke (position 2)
Frame size
A
Footprint
Position 1
A and B
EMC filter
EMC filter or
Line commutating choke
EMC filter
EMC filter or
Line commutating choke
LC filter
Position 2
Mounted on side
To the left of the inverter
(for line-side components)
Output choke
2/11
MICROMASTER 420
Options
Variant dependent options
1 AC 200 V to 240 V
3 AC 200 V to 240 V
3 AC 380 V to 480 V
1 AC 200 V to 240 V
3 AC 200 V to 240 V
3 AC 380 V to 480 V
2/12
The inverter and the associated options have the same voltage ratings.
Output
Inverter
without filter
kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11
hp
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
10.0
15.0
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3.0
4.0
5.5
2.2
3.0
4.0
5.5
7.5
11
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
4.0
5.0
7.5
3.0
4.0
5.0
7.5
10.0
15.0
6SE6420-2UC11-2AA1
6SE6420-2UC12-5AA1
6SE6420-2UC13-7AA1
6SE6420-2UC15-5AA1
6SE6420-2UC17-5AA1
6SE6420-2UC21-1BA1
6SE6420-2UC21-5BA1
6SE6420-2UC22-2BA1
6SE6420-2UC23-0CA1
6SE6420-2UC11-2AA1
6SE6420-2UC12-5AA1
6SE6420-2UC13-7AA1
6SE6420-2UC15-5AA1
6SE6420-2UC17-5AA1
6SE6420-2UC21-1BA1
6SE6420-2UC21-5BA1
6SE6420-2UC22-2BA1
6SE6420-2UC23-0CA1
6SE6420-2UC24-0CA1
6SE6420-2UC25-5CA1
6SE6420-2UD13-7AA1
6SE6420-2UD15-5AA1
6SE6420-2UD17-5AA1
6SE6420-2UD21-1AA1
6SE6420-2UD21-5AA1
6SE6420-2UD22-2BA1
6SE6420-2UD23-0BA1
6SE6420-2UD24-0BA1
6SE6420-2UD25-5CA1
6SE6420-2UD27-5CA1
6SE6420-2UD31-1CA1
Inverter
with internal filter Class A
6SE6420-2AB11-2AA1
6SE6420-2AB12-5AA1
6SE6420-2AB13-7AA1
6SE6420-2AB15-5AA1
6SE6420-2AB17-5AA1
6SE6420-2AB21-1BA1
6SE6420-2AB21-5BA1
6SE6420-2AB22-2BA1
6SE6420-2AB23-0CA1
6SE6420-2AC23-0CA1
6SE6420-2AC24-0CA1
6SE6420-2AC25-5CA1
6SE6420-2AD22-2BA1
6SE6420-2AD23-0BA1
6SE6420-2AD24-0BA1
6SE6420-2AD25-5CA1
6SE6420-2AD27-5CA1
6SE6420-2AD31-1CA1
EMC filter
Class B
6SE6400-2FA00-6AD0
6SE6400-2FL01-0AB0
with low leakage
currents
6SE6400-2FB00-6AD0
6SE6400-2FA01-4BC0
6SE6400-2FB01-4BC0
6SE6400-2FA00-6AD0
6SE6400-2FB00-6AD0
6SE6400-2FL02-6BB0
with low leakage
currents
6SE6400-2FS01-0AB0
6SE6400-2FS02-6BB0
6SE6400-2FS03-5CB0
6SE6400-2FS03-8CD0
6SE6400-2FS01-6BD0
6SE6400-2FS03-8CD0
MICROMASTER 420
Options
Variant dependent options
Mains voltage
1 AC 200 V to 240 V
3 AC 200 V to 240 V
3 AC 380 V to 480 V
1 AC 200 V to 240 V
3 AC 200 V to 240 V
3 AC 380 V to 480 V
Output
Inverter
without filter
kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11
hp
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
10.0
15.0
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3.0
4.0
5.5
2.2
3.0
4.0
5.5
7.5
11
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
4.0
5.0
7.5
3.0
4.0
5.0
7.5
10.0
15.0
6SE6420-2UC11-2AA1
6SE6420-2UC12-5AA1
6SE6420-2UC13-7AA1
6SE6420-2UC15-5AA1
6SE6420-2UC17-5AA1
6SE6420-2UC21-1BA1
6SE6420-2UC21-5BA1
6SE6420-2UC22-2BA1
6SE6420-2UC23-0CA1
6SE6420-2UC11-2AA1
6SE6420-2UC12-5AA1
6SE6420-2UC13-7AA1
6SE6420-2UC15-5AA1
6SE6420-2UC17-5AA1
6SE6420-2UC21-1BA1
6SE6420-2UC21-5BA1
6SE6420-2UC22-2BA1
6SE6420-2UC23-0CA1
6SE6420-2UC24-0CA1
6SE6420-2UC25-5CA1
6SE6420-2UD13-7AA1
6SE6420-2UD15-5AA1
6SE6420-2UD17-5AA1
6SE6420-2UD21-1AA1
6SE6420-2UD21-5AA1
6SE6420-2UD22-2BA1
6SE6420-2UD23-0BA1
6SE6420-2UD24-0BA1
6SE6420-2UD25-5CA1
6SE6420-2UD27-5CA1
6SE6420-2UD31-1CA1
Inverter
with internal filter Class A
6SE6420-2AB11-2AA1
6SE6420-2AB12-5AA1
6SE6420-2AB13-7AA1
6SE6420-2AB15-5AA1
6SE6420-2AB17-5AA1
6SE6420-2AB21-1BA1
6SE6420-2AB21-5BA1
6SE6420-2AB22-2BA1
6SE6420-2AB23-0CA1
6SE6420-2AC23-0CA1
6SE6420-2AC24-0CA1
6SE6420-2AC25-5CA1
6SE6420-2AD22-2BA1
6SE6420-2AD23-0BA1
6SE6420-2AD24-0BA1
6SE6420-2AD25-5CA1
6SE6420-2AD27-5CA1
6SE6420-2AD31-1CA1
LC filter
Output choke
6SE6400-3CC00-4AB3
6SE6400-3TD00-4AD0
6SE6400-3TC00-4AD3
6SE6400-3TC00-4AD2
6SE6400-3CC00-6AD3
6SE6400-3CC01-0BD3
6SE6400-3TD01-0BD0
6SE6400-3TC01-0BD3
6SE6400-3CC01-4BD3
6SE6400-3CC02-2CD3
6SE6400-3TD03-2CD0
6SE6400-3TC03-2CD3
6SE6400-3TC00-4AD3
6SE6400-3CC01-0BD3
6SE6400-3TD01-0BD0
6SE6400-3TC01-0BD3
6SE6400-3CC01-4BD3
6SE6400-3CC02-2CD3
6SE6400-3TD03-2CD0
6SE6400-3TC03-2CD3
6SE6400-3CC01-0AB3
6SE6400-3CC02-6BB3
6SE6400-3CC03-5CB3
6SE6400-3CC00-3AC3
6SE6400-3CC00-5AC3
6SE6400-3CC00-8BC3
6SE6400-3CC01-4BD3
6SE6400-3CC01-7CC3
6SE6400-3CC03-5CD3
6SE6400-3CC00-2AD3
6SE6400-3TC01-0BD3
6SE6400-3TC03-2CD3
6SE6400-3TC00-4AD3
2
6SE6400-3TC01-0BD3
6SE6400-3TC03-2CD3
6SE6400-3CC00-4AD3
6SE6400-3CC03-5CD3
6SE6400-3CC00-4AB3
6SE6400-3CC01-0AB3
6SE6400-3CC02-6BB3
6SE6400-3CC03-5CB3
6SE6400-3CC01-7CC3
6SE6400-3CC03-5CD3
6SE6400-3TC01-0BD3
6SE6400-3TC03-2CD3
6SE6400-3TC03-2CD3
6SE6400-3CC03-5CD3
2/13
MICROMASTER 420
Options
Variant dependent options
Mains voltage
Output
Inverter
without filter
kW
hp
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3 AC 200 V to 240 V 0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
3 AC 380 V to 480 V 0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
10.0
15.0
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3 AC 200 V to 240 V 3.0
4.0
5.5
3 AC 380 V to 480 V 2.2
3.0
4.0
5.5
7.5
11
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
4.0
5.0
7.5
3.0
4.0
5.0
7.5
10.0
15.0
1 AC 200 V to 240 V
1 AC 200 V to 240 V
2/14
6SE6420-2UC11-2AA1 6SE6400-0GP00-0AA0
6SE6420-2UC12-5AA1
6SE6420-2UC13-7AA1
6SE6420-2UC15-5AA1
6SE6420-2UC17-5AA1
6SE6420-2UC21-1BA1 6SE6400-0GP00-0BA0
6SE6420-2UC21-5BA1
6SE6420-2UC22-2BA1
6SE6420-2UC23-0CA1 6SE6400-0GP00-0CA0
6SE6420-2UC11-2AA1 6SE6400-0GP00-0AA0
6SE6420-2UC12-5AA1
6SE6420-2UC13-7AA1
6SE6420-2UC15-5AA1
6SE6420-2UC17-5AA1
6SE6420-2UC21-1BA1 6SE6400-0GP00-0BA0
6SE6420-2UC21-5BA1
6SE6420-2UC22-2BA1
6SE6420-2UC23-0CA1 6SE6400-0GP00-0CA0
6SE6420-2UC24-0CA1
6SE6420-2UC25-5CA1
6SE6420-2UD13-7AA1 6SE6400-0GP00-0AA0
6SE6420-2UD15-5AA1
6SE6420-2UD17-5AA1
6SE6420-2UD21-1AA1
6SE6420-2UD21-5AA1
6SE6420-2UD22-2BA1 6SE6400-0GP00-0BA0
6SE6420-2UD23-0BA1
6SE6420-2UD24-0BA1
6SE6420-2UD25-5CA1 6SE6400-0GP00-0CA0
6SE6420-2UD27-5CA1
6SE6420-2UD31-1CA1
Inverter
with internal filter Class A
6SE6420-2AB11-2AA1 6SE6400-0GP00-0AA0
6SE6420-2AB12-5AA1
6SE6420-2AB13-7AA1
6SE6420-2AB15-5AA1
6SE6420-2AB17-5AA1
6SE6420-2AB21-1BA1 6SE6400-0GP00-0BA0
6SE6420-2AB21-5BA1
6SE6420-2AB22-2BA1
6SE6420-2AB23-0CA1 6SE6400-0GP00-0CA0
6SE6420-2AC23-0CA1 6SE6400-0GP00-0CA0
6SE6420-2AC24-0CA1
6SE6420-2AC25-5CA1
6SE6420-2AD22-2BA1 6SE6400-0GP00-0BA0
6SE6420-2AD23-0BA1
6SE6420-2AD24-0BA1
6SE6420-2AD25-5CA1 6SE6400-0GP00-0CA0
6SE6420-2AD27-5CA1
6SE6420-2AD31-1CA1
Fuse
(see Catalog LV
10)
3NA3803
3NA3805
3NA3807
3NA3812
3NA3817
3NA3803
3NA3805
3NA3807
3NA3810
3NA3812
3NA3814
3NA3803
3NA3805
3NA3807
3NA3810
3NA3814
3NA3803
3NA3805
3NA3807
3NA3812
3NA3817
3NA3810
3NA3812
3NA3814
3NA3805
3NA3807
3NA3810
3NA3814
Circuit-breaker
3RV1021-1DA10
3RV1021-1GA10
3RV1021-1HA10
3RV1021-1JA10
3RV1021-4AA10
3RV1021-4BA10
3RV1021-4DA10
3RV1031-4FA10
3RV1031-4HA10
3RV1021-1AA10
3RV1021-1DA10
3RV1021-1EA10
3RV1021-1GA10
3RV1021-1HA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4BA10
3RV1021-4CA10
3RV1031-4EA10
3RV1031-4FA10
3RV1021-1CA10
3RV1021-1DA10
3RV1021-1EA10
3RV1021-1GA10
3RV1021-1HA10
3RV1021-1JA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4CA10
3RV1031-4EA10
3RV1031-4GA10
3RV1021-1DA10
3RV1021-1GA10
3RV1021-1HA10
3RV1021-1JA10
3RV1021-4AA10
3RV1021-4BA10
3RV1021-4DA10
3RV1031-4FA10
3RV1031-4HA10
3RV1021-4CA10
3RV1031-4EA10
3RV1031-4FA10
3RV1021-1JA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4CA10
3RV1031-4EA10
3RV1031-4GA10
MICROMASTER 420
Options
Variant independent options
Overview
Basic Operator Panel (BOP)
With the BOP, individual parameter settings can be made.
Values and units are shown on
a 5-digit display.
DeviceNet module
For networking the inverters to
the DeviceNet fieldbus system
widely used on the American
market. A maximum transmission rate of 500 Kbaud is possible. Remote control of the inverter is possible with the DeviceNet module. Remote control and operation at the inverter can be combined using an
operator panel plugged onto
the DeviceNet module.
The connection to the DeviceNet bus system is made
using a 5-pin connector with
terminal strip.
CANopen module
PROFIBUS module
For a complete PROFIBUS
connection with up to
12 Mbaud. Remote control
of the inverter is possible with
the PROFIBUS module. Remote control and operation at
the inverter can be combined
using an operator panel
plugged onto the PROFIBUS
module. The PROFIBUS module can be supplied by an external 24 V DC power supply
and is thus also active when
the inverter is disconnected
from the power supply.
Connection by means of a
9-pin Sub-D connector (available as an option).
For connecting a PC to an
AOP or AAOP. Offline programming of inverters and archiving of parameter kits possible. Includes a desktop attachment kit for an AOP or
AAOP, an RS-232 standard
cable (3 m) with Sub-D connectors and a universal power
supply unit.
Operator panel door mounting kit for single inverter
For mounting an operator panel in a control cabinet door.
Degree of protection IP56.
Contains a cable adapter
module with screwless terminals for use with users own
RS-232-cables 1).
AOP door mounting kit for
multiple inverters (USS)
For mounting an AOP or AAOP
in a control cabinet door.
Degree of protection IP56. The
AOP or AAOP can communicate with several inverters by
means of the RS-485 USS
protocol. The 4-pin connecting cable from the AOP or
AAOP to the RS-485 terminals
of the inverter and to the 24 V
user terminal strip is not
included 2).
Start-up tools
STARTER
is a graphic start-up software for guided start-up for
MICROMASTER 410/420/
430/440 frequency inverters
under Windows NT/2000/XP
Professional. Parameter lists
can be read out, altered,
stored, entered and printed.
DriveMonitor
is a start-up software for listoriented programming of
frequency inverters. This
program executes under
Windows 98/NT/2000/ME/
XP Professional.
2/15
MICROMASTER 420
Options
Variant independent options
Order No.
6SE6400-0BP00-0AA0
6SE6400-0AP00-0AA1
6SE6400-0AP00-0AB0
6SE6400-1PB00-0AA0
6SE6400-1DN00-0AA0
6SE6400-1CB00-0AA0
6GK1500-0FC00
6SE6400-1PC00-0AA0
6SE6400-0PA00-0AA0
6SE6400-0PM00-0AA0
6SE6400-0MD00-0AA0
6SL3072-0AA00-0AG0
Deflection
Acceleration
Deflection
Acceleration
Output voltage
2/16
DeviceNet module
6SE6400-1DN00-0AA0
161 mm x 73 mm x 46 mm
IP20
2 to IEC 60 664-1 (DIN VDE 0110/T1), no condensation permitted during operation
to DIN IEC 60 068-2-6 (if module is installed correctly)
0.15 mm in the frequency range of 10 Hz to 58 Hz
19.6 m/s2 in the frequency range of 58 Hz to 500 Hz
3.5 mm in the frequency range of 5 Hz to 9 Hz
9.8 m/s2 in the frequency range of 9 Hz to 500 Hz
3K3 to DIN IEC 60 721-3-3
Natural air cooling
10 C to +50 C (+14 F to +122 F)
25 C to +70 C (13 F to +158 F)
85 % (non-condensing)
95 %
to EN 55 011 (1991) Class A
to IEC 60 801-3 and EN 61 000-4-3
6.5 V 5 %, max. 300 mA,
internal from inverter or
24 V 10 %, max. 350 mA, external
5 V 10 %, max. 100 mA,
galvanically isolated supply
for terminating the serial interface bus or
for supplying the OLP (Optical Link Plug)
max. 12 Mbaud
MICROMASTER 420
Options
Variant independent options
Deflection
Acceleration
Deflection
Acceleration
161 mm x 73 mm x 46 mm
IP20
2 to IEC 60 664-1 (DIN VDE 0110/T1), no condensation permitted during operation
to IEC 60 068-2-6 (if module is installed correctly)
0.15 mm in the frequency range of 10 Hz to 58 Hz
19.6 m/s2 in the frequency range of 58 Hz to 500 Hz
3.5 mm in the frequency range of 5 Hz to 9 Hz
9.8 m/s2 in the frequency range of 9 Hz to 500 Hz
3K3 to DIN IEC 60 721-3-3
Natural air cooling
10 C to +50 C (+14 F to +122 F)
40 C to +70 C (40 F to +158 F)
25 C to +70 C (13 F to +158 F)
85 % (non-condensing)
95 %
The CAN bus is supplied from the inverter power supply
10, 20, 50, 125, 250, 500, 800 Kbaud and 1 Mbaud
Documentation
Parameter list 2)
(paper version)
Language
Multilanguage
Order No.
6SE6400-5AD00-1AP1
German
English
French
Italian
Spanish
German
English
French
Italian
Spanish
6SE6400-5AA00-0AP0
6SE6400-5AA00-0BP0
6SE6400-5AA00-0DP0
6SE6400-5AA00-0CP0
6SE6400-5AA00-0EP0
6SE6400-5BA00-0AP0
6SE6400-5BA00-0BP0
6SE6400-5BA00-0DP0
6SE6400-5BA00-0CP0
6SE6400-5BA00-0EP0
STARTER at
http://www4.ad.siemens.de/
WW/view/com/10804985/
133100
2/17
MICROMASTER 420
Dimension drawings
3 AC 380 V to 480 V
0.37 kW to 1.5 kW
2.2 kW to 4 kW
5.5 kW to 11 kW
Note:
The inverters must not be mounted horizontally.
But the inverters can be mounted without lateral spacing.
73
(2.87)
ADA51-5007c
195 (7.68)
58
(2.28)
160 (6.29)
ADA51-5000e
Fixing with
2 x M4 bolts, 2 x M4 nuts, 2 x M4 washers,
or snap onto the DIN rail
Tightening torque with washers fitted:
2.5 Nm
Ventilation clearance required at top and
bottom: 100 mm
ADA51-5008b
258 (10.16)
202 (7.95)
G_DA51_EN_05001d
174 (6.85)
Drill pattern
149 (5.87)
(6 172
.7
7)
138 (5.43)
Fixing with
4 x M4 bolts, 4 x M4 nuts, 4 x M4 washers
Tightening torque with washers fitted:
2.5 Nm
Ventilation clearance required at top and
bottom: 100 mm
309 (12.16)
ADA51-5002d
ADA51-5009b
204 (8.03)
Drill pattern
245 (9.65)
174 (6.85)
(7 195
.6
8)
DIN Rail
(5 149
.8
7)
147 (5.79)
173 (6.81)
185 (7.28)
2/18
Fixing with
4 x M5 bolts, 4 x M5 nuts, 4 x M5 washers
Tightening torque with washers fitted:
3.0 Nm
Ventilation clearance required at top
and bottom: 100 mm
MICROMASTER 420
Dimension drawings
23.5
(0.93)
73
56
(2.87)
(2.2)
149 (5.87)
120 (4.72)
24
(0.94)
185 (7.28)
156 (6.14)
38
(1.5)
4 x M5
42.5 (1.67)
49.5 (1.95)
138
(5.43)
219 (8.62)
232 (9.13)
ADA51-5012c
245 (9.65)
204 (8.03)
ADA51-5011c
213 (8.39)
174 (6.85)
174 (6.85)
187 (7.36)
ADA51-5010e
200 (7.87)
160 (6.3)
187 (7.36)
200 (7.87)
4 x M4
2 x M4
54 (2.13)
174
(6.85)
2
c
G_DA51_XX_05014e
DA51-5013e
Line commutating
choke for
Frame size A
Frame size B
Frame size C
G_DA51_XX_05050a
DA51-5049
b
75.5
(2.97)
150
(5.91)
185
(7.28)
c
50
(1.97)
50
1.3
(1.97)
50
2.3
(1.97)
Output choke
type 6SE6400-
a
200
(7.87)
213
(8.39)
280
(11.02)
Weight
(max.)
kg
0.8
3TC00-4AD2
3TC00-4AD3
3TC01-0BD3
3TC03-2CD3
Output choke
for frame size A
6SE6400-3TC00-4AD2
6SE6400-3TC00-4AD3
Dimensions
Dimensions
a
200
(7.87)
200
(7.87)
213
(8.39)
245
(9.65)
b
75.5
(2.97)
75.5
(2.97)
150
(5.91)
185
(7.28)
Weight
(max.)
kg
1.95
c
110
(4.33)
50
0.8
(1.97)
70
3.4
(2.76)
80
5.6
(3.15)
2/19
MICROMASTER 420
Dimension drawings
LC filter
100
(3.9)
120
(4.72)
G_DA51_EN_05080
G_DA51_EN_05079
G_DA51_EN_05076
334 (13.15)
300 (11.81)
56
(2.2)
Drill pattern
138
(5.43)
340 (13.38)
293 (11.53)
56
(2.2)
150 (5.9)
280 (11.02)
Drill pattern
G_DA51_EN_05077
75.5
(2.97)
287 (11.3)
110
(4.3)
2
LC filter for frame size A
140
(5.51)
185 (7.28)
Drill pattern
156 (6.14)
G_DA51_EN_05081
G_DA51_EN_05078a
382 (15.04)
335 (13.19)
320 (12.6)
174 (6.85)
2/20
Inverter
MICROMASTER 430
3/2
Description
3/4
Circuit diagrams
3/6
Technical data
3/9
3/10
Options
3/19
Dimension drawings
3/1
MICROMASTER 430
Description
Applications
Main characteristics
Output chokes
c-tick
3/2
International standards
Design
Options (overview)
Note:
See Appendix for standards.
MICROMASTER 430
Description
Mechanical features
Performance features
Modular design
Operating temperature
Digital microprocessor
10 C to +40 C
(+14 F to +104 F)
Compact housing as a result of high power density
Easy cable connection,
mains and motor connections are separated for optimum electromagnetic compatibility
Detachable operator
panels
Screwless control terminal
strip on detachable I/O
board.
control
Flux Current Control (FCC)
for improved dynamic response and optimized motor control
Linear V/f characteristic
Quadratic V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
Flying restart
Slip compensation
Automatic restart following
mains failure or fault
Energy saving mode (stopping e.g. of a pump at low
speeds)
Motor staging (connection
and disconnection of additional motors, use of inverter as control drive in a
pump cascade)
Manual/automatic mode
Load torque monitoring
(detects dry run of pumps)
Protection features
High-grade internal PID
Overload capability
7.5 kW to 90 kW:
Overload current 1.4 x rated output current (i.e.
+140 % overload capability) for 3 s, and 1.1 x rated
output current (i.e. 110 %
overload capability) for
60 s, cycle time 300 s
110 kW to 250 kW:
Overload current 1.5 x rated output current (i.e.
150 % overload capability)
for 1 s, and 1.1 x rated output current (i.e. 110 % overload capability) for 59 s,
cycle time 300 s
Overvoltage/undervoltage
protection
Inverter overtemperature
protection
Special direct connection
for PTC or KTY to protect
the motor
Earth fault protection
Short-circuit protection
I2t motor thermal protection
Locked motor protection
Stall prevention
Parameter interlock
3/3
MICROMASTER 430
Circuit diagrams
PE
3 AC 380 - 480 V
SI
2
4,7 k
0V
ADC1+
ADC1-
AA/
DD
BOP link
4
ADC2+
10
DIN1
5
DIN2
~
~
Opto isolation
DIN2
DIN3
DIN3
DIN4
DIN4
DIN5
DIN5
16
16
17
17
==
Frame sizes
C to F
B+/DC+
DC-
DIN6
PNP
or
NPN
Output +24 V
max. 100 mA
(isolated)
Output 0 V
max. 100 mA
(isolated)
9
28
28
14
DCPA
A
PTCB
15
DCNS
CPU
DCPS
DAC1+
0 - 20 mA
max. 500
12
D
DAC1-
13
DAC2+
0 - 20 mA
max. 500
26
Terminals only
for measuring
purposes
DCNA
Frame sizes
FX and GX
PTCA
Motor
PTC/
KTY 84
150.00
BOP-2
DIN1
DIN6
ADC2-
RS232
AA/
DD
11
24 V external
+
_ 24 V
L/L1, N/L2,
L3
or
L1, L2, L3
PE
+ 10 V
D
DAC2-
27
Not
used
50 Hz
1 2
DIP switch
(on control board)
19 NC
18
Relay 2
COM
22 NO
21
0 - 20 mA
current
0 - 10 V
voltage
COM
Relay 3
60 Hz
25 NO
24 NC
23
P+
29
RS485
N30
ADC ADC
1 2
DIP
switch
(on I/O
board)
1 2
COM link
PE
CB
option
3/4
automatic
U, V, W
G_DA51_EN _00012
Relay 1
COM
20 NO
MICROMASTER 430
Circuit diagrams
View A
Mains connections
Motor connections
AIN1 AIN2
S1
RL1-A
RL1-B
RL1-C
RL2-B
RL2-C
RL3-A
RL3-B
RL3-C
18
19
20
21
22
23
24
25
S2
DIP Switches:
0 mA to 20 mA
or
0 V to 10 V
DAC1+ DAC1-
12
G_DA51_EN_05107
View A
PTC
A
PTC
B
DIN5
DIN6
DAC2+
DAC2-
PE
0V
P+
N-
14
18
15
16
17
26
27
28
29
30
13
NPN *)
Analog output 1
+10 V
0V
Digital inputs
ADC1+
ADC1-
DIN1
DIN2
Analog output 2
DIN3
DIN4
RS-485
(USS-protocol)
+24 V
ADC2+
ADC2-
(DIN8)
(DIN7)
10
11
PNP *)
Voltage
supply 10 V
Analog input 1
Digital inputs
Analog input 2
3/5
MICROMASTER 430
Technical data
96 % to 97 %
97 % to 98 %
Overload current 1.4 x rated output current (i.e. +140 % overload capability) for 3 s, and
1.1 x rated output current (i.e. 110 % overload capability) for 60 s, cycle time 300 s
110 kW to 250 kW Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 1 s and
1.1 x rated output current (i.e. 110 % overload capability) for 60 s, cycle time 300 s
Inrush current
Less than rated input current
Control method
Linear V/f characteristic; quadratic V/f characteristic; multipoint characteristic
(programmable V/f characteristic); flux current control (FCC), energy saving mode
Pulse frequency
7.5 kW to 90 kW 4 kHz (standard)
2 kHz to 16 kHz (in 2 kHz steps)
110 kW to 250 kW 2 kHz (standard)
2 kHz to 4 kHz (in 2 kHz steps)
Fixed frequencies
15, programmable
Skip frequency ranges
4, programmable
Setpoint resolution
0.01 Hz digital
0.01 Hz serial
10 bit analog
Digital inputs
6 fully programmable isolated digital inputs; switchable PNP/NPN
Analog inputs
2 programmable analog inputs
0 V to 10 V, 0 mA to 20 mA and 10 V to +10 V (AIN1)
0 V to 10 V and 0 mA to 20 mA (AIN2)
both can be used as 7th/8th digital input
Relay outputs
3, programmable, 30 V DC/5 A (resistive load); 250 V AC/2A (inductive load)
Analog outputs
2, programmable (0/4 mA to 20 mA)
Serial interfaces
RS-485, optional RS-232
Motor cable length
7.5 kW to 90 kW
without output choke max. 50 m (shielded)
max. 100 m (unshielded)
without output choke see variant dependent options
110 kW to 250 kW
without output choke max. 100 m (shielded)
max. 150 m (unshielded)
with output choke see variant dependent options
Electromagnetic compatibility
7.5 kW to 90 kW Inverter with internal filter Class A available
For inverters without filter
7.5 kW to 15 kW EMC filter, Class B to EN 55 011 available as an option
18.5 kW to 90 kW EMC filter, Class B from Schaffner available as an option
110 kW to 250 kW EMC filter, Class A available as an option
Braking
DC braking, compound braking
Degree of protection
IP20
Operating temperature range
7.5 kW to 90 kW 10 C to +40 C (+14 F to +104 F)
110 kW to 250 kW 0 C to +40 C (+32 F to +104 F)
Storage temperature
40 C to +70 C (40 F to +158 F)
Relative humidity
95 % (non-condensing)
Installation altitude
7.5 kW to 90 kW Up to 1000 m above sea level without derating
110 kW to 250 kW Up to 2000 m above sea level without derating
Protection features for
undervoltage, overvoltage, overload, earth faults, short-circuits, stall prevention, locked motor protection,
motor overtemperature, inverter overtemperature, parameter change protection
Conformity with standards
3/6
MICROMASTER 430
Technical data
Derating data
Pulse frequency
Output
(for 3 AC 400 V)
kW
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
250
6 kHz
17.1
24.7
28.8
36.1
40.5
55.8
71.3
81.0
93.5
123.3
138.0
8 kHz
15.2
23.4
25.6
34.2
36.0
49.6
67.5
72.0
77.0
101.5
97.9
10 kHz
13.3
20.8
22.4
30.4
31.5
43.4
60.0
63.0
63.3
83.4
84.6
12 kHz
11.4
18.2
19.2
26.6
27.0
37.2
52.5
54.0
49.5
65.3
71.2
14 kHz
9.5
15.6
16.0
22.8
22.5
31.0
45.0
45.0
41.3
54.4
62.3
16 kHz
7.6
13.0
12.8
19.0
18.0
24.8
37.5
36.0
33.0
43.5
53.4
Operating temperature
Inverter 7.5 kW to 90 kW
G_DA51_EN_05045b
R a te d o u tp u t c u rre n t
100
%
80
60
40
4 0
2 0
20
0
-10
1 0 0
8 5
8 0
%
6 0
10
20
30
40 C 50
Operating temperature
0
0
1 0
2 0
3 0
4 0 4 5 C
5 5
O p e r a tin g te m p e r a tu r e
3/7
MICROMASTER 430
Technical data
ADA51-5018c
100
85
80
%
60
100
%
80
60
40
20
20
0
40
1000
2000
3000 m 4000
Operational altitude
3000 m 4000
Operational altitude
100
%
80
77
Mains voltage
Mains voltage
2000
ADA51-5019b
100
%
80
77
60
60
40
40
20
20
0
1000
2000
3000 m 4000
Operational altitude
3/8
1000
ADA51-5019b
1000
2000
3000 m 4000
Operational altitude
MICROMASTER 430
Selection and ordering data
kW
Rated input
current
hp
Rated output
current
Frame size
Order No.
MICROMASTER 430
without filter 4)
MICROMASTER 430
with internal filter
Class A 3)
6SE6430-2UD27-5CA0
6SE6430-2UD31-1CA0
6SE6430-2UD31-5CA0
6SE6430-2UD31-8DA0
6SE6430-2UD32-2DA0
6SE6430-2UD33-0DA0
6SE6430-2UD33-7EA0
6SE6430-2UD34-5EA0
6SE6430-2UD35-5FA0
6SE6430-2UD37-5FA0
6SE6430-2UD38-8FA0
6SE6430-2UD41-1FA0
6SE6430-2UD41-3FA0
6SE6430-2UD41-6GA0
6SE6430-2UD42-0GA0
6SE6430-2UD42-5GA0
6SE6430-2AD27-5CA0
6SE6430-2AD31-1CA0
6SE6430-2AD31-5CA0
6SE6430-2AD31-8DA0
6SE6430-2AD32-2DA0
6SE6430-2AD33-0DA0
6SE6430-2AD33-7EA0
6SE6430-2AD34-5EA0
6SE6430-2AD35-5FA0
6SE6430-2AD37-5FA0
6SE6430-2AD38-8FA0
(FS)
10
15
20
25
30
40
50
60
75
100
120
150
200
250
300
350
17.3 1)
23.1 1)
33.8 1)
37.0 1)
43.0 1)
59.0 1)
72.0 1)
87.0 1)
104.0 1)
139.0 1)
169.0 1)
200.0 2)
245.0 2)
297.0 2)
354.0 2)
442.0 2)
19
26
32
38
45
62
75
90
110
145
178
205
250
302
370
477
C
C
C
D
D
D
E
E
F
F
F
FX
FX
GX
GX
GX
Motors for
MICROMASTER 430
Catalog M 11 contains selection and ordering data for motors which are particularly suitable for operation with the
MICROMASTER 430 inverters
(see Appendix for overview).
1) Supplementary conditions:
Input current at rated operating
point, applicable at short-circuit voltage of the supply
USC = 2 % with reference to the
inverter rated power and rated
mains operating voltage of
400 V without a line commutating choke.
2) Supplementary conditions:
Input current at rated operating
point, applicable at short-circuit voltage of the supply
USC $ 2.33 % with reference to
the inverter rated power and
rated mains voltage of 400 V.
3/9
MICROMASTER 430
Options
Variant dependent options
Overview
EMC filter, Class A
Technical data
LC filter and sinusoidal filter
Mains voltage
Current (at 40 C/50 C)
For frame size C (7.5 to 15 kW)
For frame size D (18.5 kW)
For frame size D (22 kW)
For frame size D (30 kW)
For frame size E (37 kW)
For frame size E (45 kW)
For frame size F (55 kW)
For frame size F (75 kW)
For frame size F (90 kW)
For frame size FX (110 kW and 132 kW)
For frame size GX (160 kW)
For frame size GX (200 kW)
For frame size GX (250 kW)
Limiting of motor overvoltage
dV/dt limiting
Pulse frequency
Max. motor frequency
3/10
3 AC 380 V to 480 V
32.6 A/ 29.7 A
38.8 A/ 32 A
45.9 A/ 38 A
63.2 A/ 45 A
76.5 A/ 62 A
112.2 A/ 90 A
112.2 A/ 90 A
147.9 A/110 A
181.6 A/145 A
225 A/191 A
276 A/235 A
333 A/283 A
408 A/347 A
1078 V
500 V/ms
4 kHz
150 Hz
Frame sizes D to F:
The LC filters, frame sizes D
to F, are designed for
mounting upright in the control cabinet. Due to leakage
flux lines caused by physical
sources, a minimum distance of 50 mm to adjacent
modules and metal parts is
recommended.
Frame sizes FX and GX:
The sinusoidal filters, frame
sizes FX and GX, are designed for mounting upright
in the control cabinet. Due to
leakage flux lines caused by
physical sources, a minimum distance of 100 mm to
adjacent modules and metal
parts is recommended.
MICROMASTER 430
Options
Variant dependent options
shielded
unshielded
shielded
unshielded
Insulation strength
Electromagnetic compatibility
For frame sizes C to F
Installation altitude
For frame size C
Up to 2000 m:
2000 to 4000 m:
Up to 1000 m:
1000 to 4000 m:
Up to 2000 m:
2000 to 4000 m:
100 % Pn
80 % Pn
100 % Pn
80 % Pn
100 % Pn
62.5 % Pn
100 % Pn
12.5 % derating for each 1000 m
100 % Pn
7.5 % derating for each 1000 m
Footprint or suspended
upright
Top 100 mm
Bottom 100 mm
Side 100 mm
Top
Side
Input, litz wire or terminal
Output, terminals
Torque for
conductor connections
For frame size C
For frame sizes D to F
200 m
300 m
300 m
450 m
Overvoltage category III to VDE 0110
100 mm
100 mm
1U1, 1V1, 1W1
1U2, 1V2, 1W2
Terminal cross-section Torque
16 mm2
35 mm2
50 mm2
95 mm2
150 mm2
8.5 kg
21 kg
49.5 kg
67 kg
135 kg
138 kg
1.5 Nm to 1.8 Nm
2.0 Nm to 4.0 Nm
2.5 Nm to 5.0 Nm
3.0 Nm to 6.0 Nm
6.0 Nm to 12.0 Nm
10.0 Nm to 20.0 Nm
14.0 Nm to 31.0 Nm
to
to
to
to
29 kg
34 kg
67 kg
77.5 kg
to 208 kg
3/11
MICROMASTER 430
Options
Variant dependent options
Overview
Line commutating choke
Line commutating chokes are
used to smooth voltage peaks
or to bridge commutating
dips.
In addition, line commutating
chokes reduce the effects of
harmonics on the inverter and
the power supply. If the line
impedance is < 1 %, a line
commutating choke must be
used in order to reduce the
current peaks.
Output choke
Gland plate
Output chokes can be supplied for reducing the capacitive compensation currents
and dV/dt in the case of motor
cables >50 m (shielded) or
> 100 m (unshielded).
Technical data
Max. permissible cable
lengths from the motor to
the inverter when using output chokes
Note:
Operation up to 150 Hz output
frequency only!
Frame size
Output choke
(FS)
C
D to F
FX
FX
GX
GX
GX
Type
6SE6400-3TC03-2CD3
6SE6400-3TC . . -. . D0
6SL3000-2BE32-1AA0
6SL3000-2BE32-6AA0
6SL3000-2BE33-2AA0
6SL3000-2BE33-8AA0
6SL3000-2BE35-0AA0
3/12
MICROMASTER 430
Options
Variant dependent options
Design
A maximum of two footprint
G_DA51_EN_05042c
Position 2
Position 1
Frame size
C
FX
GX
Footprint
Position 1
Position 2
Mounted on side
To the left of the inverter
(for line-side components)
EMC filter
EMC filter or
Line commutating choke
LC filter
D and E
F, G, FX and GX
Output choke or
LC filter
Output choke or
LC filter
3/13
MICROMASTER 430
Options
Variant dependent options
3 AC 380 V to 480 V
Mains voltage
3 AC 380 V to 480 V
3/14
The inverter and the associated options have the same voltage ratings.
Output
hp
kW
Inverter
without filter
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
250
10
15
20
25
30
40
50
60
75
100
120
150
200
250
300
350
6SE6430-2UD27-5CA0
6SE6430-2UD31-1CA0
6SE6430-2UD31-5CA0
6SE6430-2UD31-8DA0
6SE6430-2UD32-2DA0
6SE6430-2UD33-0DA0
6SE6430-2UD33-7EA0
6SE6430-2UD34-5EA0
6SE6430-2UD35-5FA0
6SE6430-2UD37-5FA0
6SE6430-2UD38-8FA0
6SE6430-2UD41-1FA0
6SE6430-2UD41-3FA0
6SE6430-2UD41-6GA0
6SE6430-2UD42-0GA0
6SE6430-2UD42-5GA0
6SL3000-0BE32-5AA0 *)
6SL3000-0BE34-4AA0 *)
Output
kW
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
250
hp
10
15
20
25
30
40
50
60
75
100
120
150
200
250
300
350
Inverter
without filter
Output
kW
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
250
6SE6430-2UD27-5CA0
6SE6430-2UD31-1CA0
6SE6430-2UD31-5CA0
6SE6430-2UD31-8DA0
6SE6430-2UD32-2DA0
6SE6430-2UD33-0DA0
6SE6430-2UD33-7EA0
6SE6430-2UD34-5EA0
6SE6430-2UD35-5FA0
6SE6430-2UD37-5FA0
6SE6430-2UD38-8FA0
6SE6430-2UD41-1FA0
6SE6430-2UD41-3FA0
6SE6430-2UD41-6GA0
6SE6430-2UD42-0GA0
6SE6430-2UD42-5GA0
Inverter
without filter
hp
10
15
20
25
30
40
50
60
75
100
120
150
200
250
300
350
6SE6430-2UD27-5CA0
6SE6430-2UD31-1CA0
6SE6430-2UD31-5CA0
6SE6430-2UD31-8DA0
6SE6430-2UD32-2DA0
6SE6430-2UD33-0DA0
6SE6430-2UD33-7EA0
6SE6430-2UD34-5EA0
6SE6430-2UD35-5FA0
6SE6430-2UD37-5FA0
6SE6430-2UD38-8FA0
6SE6430-2UD41-1FA0
6SE6430-2UD41-3FA0
6SE6430-2UD41-6GA0
6SE6430-2UD42-0GA0
6SE6430-2UD42-5GA0
6SE6400-3CC03-5CD3
EMC filter, Class B,
6SE6400-3CC04-4DD0
available from Schaffner
6SE6400-3CC05-2DD0
6SE6400-3CC08-3ED0
6SE6400-3CC11-2FD0
6SL3000-0BE36-0AA0 *)
6SE6400-3TD03-7DD0
6SE6400-3TD04-8DD0
6SE6400-3TD06-1DD0
6SE6400-3TD07-2ED0
6SE6400-3TD11-5FD0
6SE6400-3TD15-0FD0
6SE6400-3TD18-0FD0
6SL3000-2CE32-3AA0
6SL3000-2CE32-8AA0
6SL3000-2CE33-3AA0
6SL3000-2CE34-1AA0
Line commutating
choke
6SE6400-3CC02-2CD3
6SE6400-3CC11-7FD0
6SL3000-0CE32-3AA0
6SL3000-0CE32-8AA0
6SL3000-0CE33-3AA0
6SL3000-0CE35-1AA0
Output choke
6SE6400-3TC03-2CD3
Gland plate
6SE6400-0GP00-0CA0
6SE6400-3TC05-4DD0
6SE6400-3TC03-8DD0
6SE6400-3TC05-4DD0
6SE6400-3TC08-0ED0
6SE6400-3TC07-5ED0
6SE6400-3TC14-5FD0
6SE6400-3TC15-4FD0
6SE6400-3TC14-5FD0
Integrated as standard
6SL3000-2BE32-1AA0
6SL3000-2BE32-6AA0
6SL3000-2BE33-2AA0
6SL3000-2BE33-8AA0
6SL3000-2BE35-0AA0
3NE1230-0
3NE1332-0
3NE1333-0
3NE1435-0
Circuit-breaker
(see Catalog LV 10)
3RV1031-4EA10
3RV1031-4FA10
3RV1031-4HA10
3RV1042-4KA10
3RV1042-4MA10
3VL1712- . DD33- . . . .
3VL1716- . DD33- . . . .
3VL3720- . DC36- . . . .
3VL3725- . DC36- . . . .
3VL4731- . DC36- . . . .
3VL3725- . DC36- . . . .
3VL4731- . DC36- . . . .
3VL4740- . DC36- . . . .
3VL5750- . DC36- . . . .
MICROMASTER 430
Options
Variant dependent options
Mains voltage
3 AC 380 V to 480 V
Mains voltage
3 AC 380 V to 480 V
Mains voltage
3 AC 380 V to 480 V
Output
kW
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
hp
10
15
20
25
30
40
50
60
75
100
120
Output
kW
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
hp
10
15
20
25
30
40
50
60
75
100
120
Output
kW
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
hp
10
15
20
25
30
40
50
60
75
100
120
Inverter
with internal filter
Class A
6SE6430-2AD27-5CA0
6SE6430-2AD31-1CA0
6SE6430-2AD31-5CA0
6SE6430-2AD31-8DA0
6SE6430-2AD32-2DA0
6SE6430-2AD33-0DA0
6SE6430-2AD33-7EA0
6SE6430-2AD34-5EA0
6SE6430-2AD35-5FA0
6SE6430-2AD37-5FA0
6SE6430-2AD38-8FA0
Line commutating
choke
6SE6400-3CC02-2CD3
6SE6400-3CC03-5CD3
6SE6400-3CC04-4DD0
6SE6400-3CC05-2DD0
6SE6400-3CC08-3ED0
6SE6400-3TD03-2CD0
6SE6400-3TD03-7DD0
6SE6400-3TD04-8DD0
6SE6400-3TD06-1DD0
6SE6400-3TD07-2ED0
6SE6400-3TD11-5FD0
6SE6400-3CC11-2FD0
6SE6400-3CC11-7FD0
Inverter
with internal filter
Class A
Gland plate
6SE6430-2AD27-5CA0
6SE6430-2AD31-1CA0
6SE6430-2AD31-5CA0
6SE6430-2AD31-8DA0
6SE6430-2AD32-2DA0
6SE6430-2AD33-0DA0
6SE6430-2AD33-7EA0
6SE6430-2AD34-5EA0
6SE6430-2AD35-5FA0
6SE6430-2AD37-5FA0
6SE6430-2AD38-8FA0
6SE6400-3TC03-2CD3
6SE6400-0GP00-0CA0
6SE6400-3TC05-4DD0
6SE6400-3TC03-8DD0
6SE6400-3TC05-4DD0
6SE6400-3TC08-0ED0
6SE6400-3TC07-5ED0
6SE6400-3TC14-5FD0
6SE6400-3TC15-4FD0
6SE6400-3TC14-5FD0
Integrated as standard
6SE6430-2AD27-5CA0
6SE6430-2AD31-1CA0
6SE6430-2AD31-5CA0
6SE6430-2AD31-8DA0
6SE6430-2AD32-2DA0
6SE6430-2AD33-0DA0
6SE6430-2AD33-7EA0
6SE6430-2AD34-5EA0
6SE6430-2AD35-5FA0
6SE6430-2AD37-5FA0
6SE6430-2AD38-8FA0
LC filter
6SE6400-3TD15-0FD0
6SE6400-3TD18-0FD0
3
Circuit-breaker
(see Catalog LV 10)
3RV1031-4EA10
3RV1031-4FA10
3RV1031-4HA10
3RV1042-4KA10
3RV1042-4MA10
3VL1712- . DD33- . . . .
3VL1716- . DD33- . . . .
3VL3720- . DC36- . . . .
3VL3725- . DC36- . . . .
3VL4731- . DC36- . . . .
3/15
MICROMASTER 430
Options
Variant independent options
Overview
Basic Operator Panel 2
(BOP-2)
With the BOP-2, individual parameter settings can be made.
Values and units are shown on
a 5-digit display.
PROFIBUS module
CANopen module
Start-up tools
STARTER
is a graphic start-up software for guided start-up for
MICROMASTER 410/420/
430/440 frequency inverters
under Windows NT/2000/
XP Professional. Parameter
lists can be read out, altered, stored, entered and
printed.
Connection by means of a
9-pin Sub-D connector (available as an option).
Basic Operator Panel (BOP-2)
DeviceNet module
A BOP-2 can be used for several inverters. It can be directly mounted on the inverter or in
a control cabinet door using a
mounting kit.
DriveMonitor
is a start-up software for listoriented programming of
frequency inverters. This
program executes under
Windows 98/NT/2000/ME/
XP Professional.
Both programs are included
on the Docu CD which is provided with every inverter.
3/16
Order No.
6SE6400-0BE00-0AA0
6SE6400-1PB00-0AA0
6SE6400-1DN00-0AA0
6SE6400-1CB00-0AA0
6GK1500-0FC00
6SE6400-1PC00-0AA0
6SE6400-0PM00-0AA0
6SL3072-0AA00-0AG0
MICROMASTER 430
Options
Variant independent options
Deflection
Acceleration
Deflection
Acceleration
Output voltage
DeviceNet module
6SE6400-1DN00-0AA0
161 mm x 73 mm x 46 mm
IP20
2 to IEC 60 664-1 (DIN VDE 0110/T1), no condensation permitted during operation
to IEC 60 068-2-6 (if module is installed correctly)
0.15 mm in the frequency range of 10 Hz to 58 Hz
19.6 m/s2 in the frequency range of 58 Hz to 500 Hz
3.5 mm in the frequency range of 5 Hz to 9 Hz
9.8 m/s2 in the frequency range of 9 Hz to 500 Hz
3K3 to IEC 60 721-3-3
Natural air cooling
10 C to +50 C (+14 F to +122 F)
25 C to +70 C (13 F to +158 F)
85 % (non-condensing)
95 %
to EN 55 011 (1991) Class A
to IEC 60 801-3 and EN 61 000-4-3
6.5 V 5 %, max. 300 mA,
internal from inverter or
24 V 10 %, max. 350 mA, external
5 V 10 %, max. 100 mA,
galvanically isolated supply
for terminating the serial interface bus or
for supplying the OLP (Optical Link Plug)
max. 12 Mbaud
3
6.5 V 5 %, max. 300 mA
internal from inverter or
24 V, max. 60 mA from DeviceNet-Bus
3/17
MICROMASTER 430
Options
Variant independent options
Deflection
Acceleration
Deflection
Acceleration
161 mm x 73 mm x 46 mm
IP20
2 to IEC 60 664-1 (DIN VDE 0110/T1), no condensation permitted during operation
to IEC 60 068-2-6 (if module is installed correctly)
0.15 mm in the frequency range of 10 Hz to 58 Hz
19.6 m/s2 in the frequency range of 58 Hz to 500 Hz
3.5 mm in the frequency range of 5 Hz to 9 Hz
9.8 m/s2 in the frequency range of 9 Hz to 500 Hz
3K3 to IEC 60 721-3-3
Natural air cooling
10 C to +50 C (+14 F to +122 F)
40 C to +70 C (40 F to +158 F)
25 C to +70 C (13 F to +158 F)
85 % (non-condensing)
95 %
The CAN bus is supplied from the inverter power supply
10, 20, 50, 125, 250, 500, 800 Kbaud and 1 Mbaud
Documentation
Parameter list 2)
(paper version)
3/18
Language
Multilanguage
Order No.
6SE6400-5AD00-1AP1
German
English
French
Italian
Spanish
German
English
French
Italian
Spanish
6SE6400-5AE00-0AP0
6SE6400-5AE00-0BP0
6SE6400-5AE00-0DP0
6SE6400-5AE00-0CP0
6SE6400-5AE00-0EP0
6SE6400-5AF00-0AP0
6SE6400-5AF00-0BP0
6SE6400-5AF00-0DP0
6SE6400-5AF00-0CP0
6SE6400-5AF00-0EP0
STARTER at
http://www4.ad.siemens.de/
WW/view/com/10804985/
133100
MICROMASTER 430
Dimension drawings
Note:
The inverters must not be mounted horizontally.
But the inverters can be mounted without lateral spacing.
3 AC 380 V to 480 V
7.5 kW to 15 kW
18.5 kW to 30 kW
37 kW to 45 kW
ADA51-5009b
309 (12.16)
ADA51-5002d
245 (9.65)
204 (8.03)
Drill pattern
174 (6.85)
(7 195
.6
8)
Fixing with
4 x M5 bolts
4 x M5 nuts
4 x M5 washers
Tightening torque with washers fitted:
3.0 Nm
Ventilation clearance required at top
and bottom: 100 mm
185 (7.28)
Drill pattern
Fixing with
4 x M8 bolts
4 x M8 nuts
4 x M8 washers
Tightening torque with
washers fitted: 3.0 Nm
Ventilation clearance
required at top and bottom:
300 mm
616.4 (24.27)
650 (25.59)
ADA51-5021b
486 (19.13)
235 (9.25)
275 (10.82)
(9 245
.6
5)
275 (10.82)
(9 245
.6
5)
ADA51-5020b
520 (20.47)
Drill pattern
235 (9.25)
Fixing with
4 x M8 bolts
4 x M8 nuts
4 x M8 washers
Tightening torque with
washers fitted: 3.0 Nm
Ventilation clearance
required at top and bottom:
300 mm
3/19
MICROMASTER 430
Dimension drawings
Note:
The inverters must not be mounted horizontally.
But the inverters can be mounted without lateral spacing.
3 AC 380 V to 480 V
55 kW to 90 kW
Drill pattern
1110 (43.70)
1150 (45.28)
300 (11.81)
350 (13.78)
(1 320
2.
6)
350 (13.78)
Fixing with
4 x M8 bolts
4 x M8 nuts
4 x M8 washers
Tightening torque with
washers fitted: 3.0 Nm
Ventilation clearance
required at top and bottom:
350 mm
ADA51-5023b
810 (31.89)
300 (11.81)
(1 320
2.
6)
ADA51-5022b
850 (33.46)
Drill pattern
Fixing with
4 x M8 bolts
4 x M8 nuts
4 x M8 washers
Tightening torque with
washers fitted: 3.0 Nm
Ventilation clearance
required at top and bottom:
350 mm
3/20
MICROMASTER 430
Dimension drawings
Note:
The inverters must not be mounted horizontally.
But the inverters can be mounted without lateral spacing.
3 AC 380 V to 480 V
110 kW to 132 kW
160 kW to 250 kW
Drill pattern
Drill pattern
125 125
(4.92) (4.92)
1533 (60.35)
326
(12.83)
(2 54
1. 5
46
)
Fixing with
6 x M8 bolts
6 x M8 nuts
6 x M8 washers
Tightening torque
with washers
fitted: 13.0 Nm
Ventilation clearance
required:
at top: 250 mm
at bottom: 150 mm
in front: 40 mm
G_DA51_EN_05075
1375 (54.13)
1400 (55.12)
(1 35
4. 6
06
)
G_DA51_EN_05074
326
(12.83)
125 125
(4.92) (4.92)
1508 (59.37)
125 125
(4.92) (4.92)
125 125
(4.92) (4.92)
Fixing with
6 x M8 bolts
6 x M8 nuts
6 x M8 washers
Tightening torque
with washers
fitted: 13.0 Nm
Ventilation clearance
required:
at top: 250 mm
at bottom: 150 mm
in front: 50 mm
3/21
MICROMASTER 430
Dimension drawings
EMC filter
185 (7.28)
156 (6.14)
38
(1.5)
ADA51-5012c
245 (9.65)
204 (8.03)
219 (8.62)
232 (9.13)
4 x M5
54 (2.13)
174
(6.85)
b1
n4
a1
n3
G_DA51_XX_05103
EMC filter
Class A
Type
6SL30000BE32-5AA0
for inverter
Frame size
(FS)
Dimensions
a
a1
b1
n3
n4
FX
0BE34-4AA0
FX/GX
0BE36-0AA0
GX
270
(10.63)
270
(10.63)
310
(12.2)
360
(14.17)
360
(14.17)
400
(15.75)
200
(7.87)
200
(7.87)
215
(8.46)
240
(9.45)
240
(9.45)
265
(10.43)
116
(4.57)
116
(4.57)
140
(5.51)
210
(8.27)
210
(8.27)
250
(9.84)
220
(8.66)
220
(8.66)
240
(9.45)
Weight,
approx.
kg
12.3
12.3
19.0
3/22
MICROMASTER 430
Dimension drawings
LC filter
185 (7.28)
140
(5.51)
Drill pattern
156 (6.14)
G_DA51_EN_05081
G_DA51_EN_05078a
382 (15.04)
335 (13.19)
320 (12.6)
174 (6.85)
LC filter
Type
for inverter
Frame size
(FS)
6SE6400-3TD03-7DD0
6SE6400-3TD04-8DD0
6SE6400-3TD06-1DD0
6SE6400-3TD07-2ED0
6SE6400-3TD11-5FD0
E/F
6SE6400-3TD15-0FD0
6SE6400-3TD18-0FD0
G_DA51_XX_05082
n2
n1
Dimensions
a
278
(10.94)
290
(11.42)
345
(13.58)
355
(13.98)
460
(18.11)
460
(18.11)
520
(20.47)
b
240
(9.45)
240
(9.45)
300
(11.81)
300
(11.81)
360
(14.17)
360
(14.17)
420
(16.54)
3
c
230
(9.06)
240
(9.45)
220
(8.66)
235
(9.25)
235
(9.25)
250
(9.84)
290
(11.42)
n1
115
(4.53)
125
(4.92)
120
(4.72)
145
(5.71)
125
(4.92)
140
(5.51)
173
(6.81)
n2
190
(7.48)
190
(7.48)
240
(9.45)
240
(9.45)
264
(10.39)
264
(10.39)
316
(12.44)
3/23
MICROMASTER 430
Dimension drawings
Sinusoidal filter
G_DA51_XX_00013
n1
n2
n3
n4
for inverter
Frame size (FS)
2CE32-3AA0
FX
2CE32-8AA0
GX
Dimensions
a
300
(11.81)
300
(11.81)
b
620
(24.41)
620
(24.41)
c
320
(12.6)
320
(12.6)
n1
280
(11.02)
280
(11.02)
n2
105
(4.13)
105
(4.13)
n3
225
(8.86)
225
(8.86)
n4
150
(5.91)
150
(5.91)
Weight
(max.)
kg
135.0
138.0
G_DA51_XX_00014
3
n1
n2
n3
n4
for inverter
Frame size (FS)
2CE33-3AA0
GX
2CE34-1AA0
GX
Dimensions
a
370
(14.57)
370
(14.57)
b
620
(24.41)
620
(24.41)
c
360
(14.17)
360
(14.17)
n1
320
(12.6)
320
(12.6)
n2
105
(4.13)
105
(4.13)
n3
225
(8.86)
225
(8.86)
n4
150
(5.91)
150
(5.91)
Weight
(max.)
kg
144.0
208.0
3/24
MICROMASTER 430
Dimension drawings
Line commutating
choke for
DA51-5051
G_DA51_XX_05014e
Dimensions
a
b
280
185
(11.02) (7.28)
Frame size C
c
50
(1.97)
Line commutating
choke for
Weight
(max.)
kg
2.3
Frame size D
Frame size E
Dimensions
a
520
(20.47)
650
(25.59)
b
275
(10.83)
275
(10.83)
c
85
(3.35)
95
(3.74)
Weight
(max.)
kg
9.5
17.0
G_DA51_XX_05052
Line commutating
choke
Type 6SE64003CC11-....
n1
n2
for inverter
Dimensions
Frame size
F
a
b
c
n1
n2
228
240
141
95
185
(8.98) (9.45) (5.55) (3.74) (7.28)
Weight
(max.)
kg
25.0
G_DA51_XX_05053
Weight
(max.)
c
203
(7.99)
203
(7.99)
210
(8.27)
n1
101
(3.98)
101
(3.98)
118
(4.65)
n2
200
(7.87)
200
(7.87)
224
(8.82)
kg
24.0
25.0
35.0
n1
n2
3/25
MICROMASTER 430
Dimension drawings
Output chokes
b
G_DA51_XX_05050a
Dimensions
Frame size C
a
b
c
245
185
80
(9.65) (7.28) (3.15)
Weight
(max.)
kg
5.6
G_DA51_XX_05052
Output chokes
for inverters of size D, E and F
G_DA51_XX_05053
n1
n2
Output
choke
Type
6SE6400-
3TC03-8DD0
3TC05-4DD0
3TC07-5ED0
3TC08-0ED0
3TC14-5FD0
3TC15-4FD0
Output
choke
Type
6SL30002BE32-1AA0
2BE32-6AA0
FX
2BE33-2AA0
GX
2BE33-8AA0
GX
2BE35-0AA0
GX
FX
210
(8.27)
210
(8.27)
248
(9.76)
210
(8.27)
321
(12.64)
248
(9.76)
285
(11.22)
315
(12.4)
285
(11.22)
285
(11.22)
365
(14.37)
225
(8.86)
225
(8.86)
270
(10.63)
225
(8.86)
350
(13.78)
270
(10.63)
300
(11.81)
300
(11.81)
300
(11.81)
300
(11.81)
300
(11.81)
c
179
(7.05)
150
(5.91)
209
(8.23)
150
(5.91)
288
(11.34)
209
(8.23)
n1
n2
(to DIN 41308)
94
176
(3.70)
(6.93)
70
176
(2.76)
(6.93)
101
200
(3.98)
(7.87)
70
176
(2.76)
(6.93)
138
264
(5.43)
(10.39)
101
200
(3.98)
(7.87)
n1
n2
257
(10.12)
277
(10.91)
257
(10.12)
277
(10.91)
277
(10.91)
163
(6.42)
183
(7.2)
163
(6.42)
183
(7.2)
183
(7.2)
224
(8.82)
224
(8.82)
224
(8.82)
224
(8.82)
224
(8.82)
Weight
(max.)
kg
16.1
10.7
24.9
10.4
51.5
24.0
Weight
(max.)
kg
60.0
66.0
62.0
73.0
100.0
n1
n2
Output chokes
for inverters of size FX and GX
3/26
Inverter
MICROMASTER 440
4/2
Description
4/4
Circuit diagrams
4/6
Technical data
4/9
4/12
Options
4/26
Dimension drawings
4/1
MICROMASTER 440
Description
Applications
The MICROMASTER 440 inverter is suitable for a variety
of variable-speed drive applications. Its flexibility provides
for a wide spectrum of applications. These also include
cranes and hoisting gear,
high-bay warehouses, production machines for food,
beverages and tobacco,
packaging machines etc.; i.e.
applications which require the
frequency inverter to have a
higher functionality and dynamic response than usual.
The inverter is especially characterized by its customer-oriented performance and easeof-use. Its large mains voltage
range enables it to be used all
over the world.
Design
The MICROMASTER 440 inverter has a modular design.
The operator panels and modules can be easily exchanged.
International standards
The MICROMASTER 440
c-tick
Note:
See Appendix for standards.
Main characteristics
Options (overview)
4/2
MICROMASTER 440
Description
Mechanical features
Performance features
Modular design
Operating temperature
Digital microprocessor
0.12 kW to 75 kW:
10 C to +50 C
(+14 F to +122 F)
90 kW to 200 kW:
0 C to +40 C
(+32 F to +104 F)
Compact housing as a result of high power density
Easy cable connection,
mains and motor connections are separated for optimum electromagnetic compatibility
Detachable operator
panels
Screwless control terminals
on detachable I/O board.
control
High-quality Vector Control
system
Flux Current Control (FCC)
for improved dynamic response and optimized motor control
Linear V/f characteristic
Quadratic V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
Torque control
Flying restart
Slip compensation
Automatic restart following
mains failure or fault
User-definable function
blocks for logic and arithmetic operations
Kinetic buffering
Positioning ramp down
High-grade PID controller
for simple internal process
control (autotuning)
Programmable acceleration/deceleration, 0 s to
650 s
Ramp smoothing
Fast Current Limit (FCL) for
trip-free operation
Fast, repeatable digital input response time
Fine adjustment using two
high-resolution 10-bit analog inputs
Compound braking for controlled rapid braking
Integrated brake chopper
(for 0.12 kW to 75 kW inverters)
Four skip frequencies
Removable Y capacitor
for use on IT systems (with
non-grounded mains supplies, the Y capacitor
must be removed and an
output choke installed).
Protection features
Overload capability
Overvoltage/undervoltage
CT mode
0.12 kW to 75 kW:
Overload current 1.5 x
rated output current (i.e.
150 % overload capability) for 60 s, cycle time
300 s, and 2 x rated output current (i.e. 200 %
overload capability) for
3 s, cycle time 300 s
90 kW to 200 kW:
Overload current 1.36 x
rated output current (i.e.
136 % overload capability) for 57 s, cycle time
300 s, and 1.6 x rated output current (i.e. 160 %
overload capability) for
3 s, cycle time 300 s
VT mode
5.5 kW to 90 kW:
Overload current 1.4 x
rated output current (i.e.
140 % overload capability) for 3 s, and 1.1 x rated
output current (i.e. 110 %
overload capability) for
60 s, cycle time 300 s
110 kW to 250 kW:
Overload current 1.5 x
rated output current (i.e.
150 % overload capability) for 1 s, and 1.1 x rated
output current (i.e. 110 %
overload capability) for
59 s, cycle time 300 s
protection
Inverter overtemperature
protection
Special direct connection
4/3
MICROMASTER 440
Circuit diagrams
2
4,7 k
0V
ADC1+
ADC1-
AA/
DD
BOP link
4
ADC2+
10
150.00
BOP/AOP
DIN1
DIN1
5
DIN2
~
~
Opto isolation
DIN2
DIN3
DIN3
DIN4
DIN4
DIN5
+
_ 24 V
ADC2-
RS232
AA/
DD
11
24 V external
DIN6
L/L1, N/L2,
or
L/L1, N/L2, L3
or
L1, L2, L3
PE
+ 10 V
==
Frame sizes
A to F
B+/DC+
DIN5
DC-
16
16
17
DC-
17
PNP
or
NPN
Output +24 V
max. 100 mA
(isolated)
Output 0 V
max. 100 mA
(isolated)
9
28
28
Frame sizes
FX and GX
PTCA
Motor
PTC/
KTY 84
14
DCNA
A
PTCB
DCPA
D
15
DCNS
CPU
DCPS
DAC1+
0 - 20 mA
max. 500
12
D
DAC1-
Terminal
for
dv/dt Filter
=
DAC2+
26
Terminal
for
external
brake unit
13
0 - 20 mA
max. 500
B-
DIN6
D
DAC2-
27
4
30 V DC/5 A (resistive load)
250 V AC/2 A (inductive load)
Not
used
50 Hz
1 2
DIP switch
(on control board)
19 NC
18
COM
Relay 2 22 NO
21
0 - 20 mA
current
0 - 10 V
voltage
COM
Relay 3
60 Hz
25 NO
24
NC
23
ADC ADC
1 2 DIP
switch
on I/O
board
1 2
P+
29
N-
RS485
COM link
30
PE
CB
option
4/4
automatic
U, V, W
G_DA51_EN_05024h
Relay 1
COM
20 NO
MICROMASTER 440
Circuit diagrams
View A
Motor connections
AIN1 AIN2
S1
RL1-A
RL1-B
RL1-C
RL2-B
RL2-C
RL3-A
RL3-B
RL3-C
18
19
20
21
22
23
24
25
S2
DIP Switches:
0 mA to 20 mA
or
0 V to 10 V
DAC1+ DAC1-
12
G_DA51_EN_05107
View A
PTC
A
PTC
B
DIN5
DIN6
DAC2+
DAC2-
PE
0V
P+
N-
14
18
15
16
17
26
27
28
29
30
13
NPN *)
Analog output 1
+10 V
0V
Digital inputs
ADC1+
ADC1-
DIN1
DIN2
Analog output 2
DIN3
DIN4
RS-485
(USS-protocol)
+24 V
ADC2+
ADC2-
(DIN8)
(DIN7)
10
11
PNP *)
Voltage
supply 10 V
Analog input 1
Digital inputs
Analog input 2
4/5
MICROMASTER 440
Technical data
CT (constant torque)
VT (variable torque)
1 AC 200 V to 240 V 10 % 0.12 kW to 3 kW
Vector control, torque control, linear V/f characteristic; quadratic V/f characteristic;
Multipoint characteristic (programmable V/f characteristic); flux current control (FCC)
Pulse frequency
0.12 kW to 75 kW 4 kHz (standard); 16 kHz (standard with 230 V inverters 0.12 kW to 5.5 kW)
2 kHz to 16 kHz (in 2 kHz steps)
90 kW to 200 kW 2 kHz (standard with VT mode); 4 kHz (standard with CT mode)
2 kHz to 4 kHz (in 2 kHz steps)
Fixed frequencies
15, programmable
Skip frequency ranges
4, programmable
Setpoint resolution
0.01 Hz digital
0.01 Hz serial
10 bit analog
Digital inputs
6 fully programmable isolated digital inputs; switchable PNP/NPN
Analog inputs
Relay outputs
Analog outputs
Serial interfaces
Motor cable lengths
without output choke
4/6
A
B
C
D
E
F without filter
F with filter
FX
GX
CFM: Cubic Flow per Minute
Cooling-air volumetric
flow required (l/s)/(CFM)
4.8/10.2
24/51
54.9/116.3
2 x 54.9/2 x 116.3
2 x 54.9/2 x 116.3
150/317.79
150/317.79
225/478.13
440/935
xW
173
202
245
520
650
850
1150
1400
1533
x 73
x 149
x 185
x 275
x 275
x 350
x 350
x 326
x 326
x 149
x 172
x 195
x 245
x 245
x 320
x 320
x 356
x 545
1.3
3.4
5.7
17
22
56
75
116
176
MICROMASTER 440
Technical data
Derating data
Pulse frequency
Output
kW
Mains voltage 1/3 AC 200 V
0.12 to 5.5
4 kHz
6 kHz
8 kHz
10 kHz
110
205.0
132
250.0
160
302.0
200
370.0
12 kHz
14 kHz
16 kHz
19.6
25.2
32.4
47.6
48.0
62.4
78.0
92.4
16.8
21.0
27.0
40.8
40.0
57.2
71.5
84.7
14.0
16.8
21.6
34.0
32.0
52.0
65.0
77.0
1.3
1.5
1.8
2.2
2.5
4.1
4.6
6.1
7.9
13.3
15.6
22.4
22.8
27.0
43.4
45.0
40.5
49.5
58.0
1.2
1.4
1.5
1.9
2.1
3.5
3.9
5.1
6.6
11.4
13.0
19.2
19.0
22.5
37.2
37.5
33.8
41.3
50.8
1.0
1.2
1.3
1.6
1.6
3.0
3.1
4.1
5.3
9.5
10.4
16.0
15.2
18.0
31.0
30.0
27.0
33.0
43.5
0.7
1.1
1.2
1.8
2.7
4.4
5.1
8.8
8.1
9.6
16.4
15.6
37.2
46.2
59.4
0.6
0.9
1.0
1.5
2.3
3.9
4.3
7.7
6.8
8.0
14.4
13.0
32.6
42.4
52.0
0.6
0.8
0.8
1.2
1.8
3.3
3.4
6.6
5.4
6.4
12.3
10.4
27.9
38.5
44.6
4/7
MICROMASTER 440
Technical data
Inverter 90 kW to 200 kW
A D A 5 1 -5 0 4 7 a
VT
CT
R a te d o u tp u t c u rre n t
G_DA51_EN_05026c
100
%
80
70
60
50
40
1 0 0
8 5
8 0
%
6 0
4 0
2 0
20
0
-10
10
20
30 40 50 60 C 70
Operating temperature
2 0
1 0
5 5
3 0
4 0 4 5 C
O p e r a tin g te m p e r a tu r e
Inverter 90 kW to 200 kW
ADA51-5046
ADA51-5018c
100
85
80
%
60
100
%
80
60
40
20
20
0
40
1000
2000
3000 m 4000
Operational altitude
1000
2000
3000 m 4000
Operational altitude
Inverter 90 kW to 200 kW
ADA51-5019b
ADA51-5019b
100
%
80
77
Mains voltage
Mains voltage
100
%
80
77
60
60
40
40
20
20
1000
2000
3000 m 4000
Operational altitude
4/8
1000
2000
3000 m 4000
Operational altitude
MICROMASTER 440
Selection and ordering data
Rated output
current
A
VT (variable torque)
Output
Rated input
current 1)
kW
hp
A
Rated output
current
A
0.16
0.33
0.50
0.75
1.0
1.5
2
3
4
1.8
3.2
4.6
6.2
8.2
11.0
14.4
20.2
35.5
0.9
1.7
2.3
3.0
3.9
5.5
7.4
10.4
13.6
A
A
A
A
A
B
B
B
C
1.3
1.3
1.3
1.3
1.3
3.3
3.3
3.3
5.5
6SE6440-2UC11-2AA1
6SE6440-2UC12-5AA1
6SE6440-2UC13-7AA1
6SE6440-2UC15-5AA1
6SE6440-2UC17-5AA1
6SE6440-2UC21-1BA1
6SE6440-2UC21-5BA1
6SE6440-2UC22-2BA1
6SE6440-2UC23-0CA1
7.5
10
15
20
25
30
40
50
60
75
28.3
34.2
38.0
50.0
62.0
71.0
96.0
114.0
135.0
164.0
22
28
42
54
68
80
104
130
154
178
A
A
A
A
A
B
B
B
C
C
C
D
D
D
E
E
F
F
F
1.3
1.3
1.3
1.3
1.3
3.3
3.3
3.3
5.5
5.5
5.5
16
16
16
20
20
55
55
55
6SE6440-2UC11-2AA1
6SE6440-2UC12-5AA1
6SE6440-2UC13-7AA1
6SE6440-2UC15-5AA1
6SE6440-2UC17-5AA1
6SE6440-2UC21-1BA1
6SE6440-2UC21-5BA1
6SE6440-2UC22-2BA1
6SE6440-2UC23-0CA1
6SE6440-2UC24-0CA1
6SE6440-2UC25-5CA1
6SE6440-2UC27-5DA1
6SE6440-2UC31-1DA1
6SE6440-2UC31-5DA1
6SE6440-2UC31-8EA1
6SE6440-2UC32-2EA1
6SE6440-2UC33-0FA1
6SE6440-2UC33-7FA1
6SE6440-2UC34-5FA1
10
15
20
25
30
40
50
60
75
100
125
17.3
23.1
33.8
37.0
43.0
59.0
72.0
87.0
104.0
139.0
169.0
19
26
32
38
45
62
75
90
110
145
178
A
A
A
A
A
B
B
B
C
C
C
D
D
D
E
E
F
F
F
1.3
1.3
1.3
1.3
1.3
3.3
3.3
3.3
5.5
5.5
5.5
16
16
16
20
20
56
56
56
6SE6440-2UD13-7AA1
6SE6440-2UD15-5AA1
6SE6440-2UD17-5AA1
6SE6440-2UD21-1AA1
6SE6440-2UD21-5AA1
6SE6440-2UD22-2BA1
6SE6440-2UD23-0BA1
6SE6440-2UD24-0BA1
6SE6440-2UD25-5CA1
6SE6440-2UD27-5CA1
6SE6440-2UD31-1CA1
6SE6440-2UD31-5DA1
6SE6440-2UD31-8DA1
6SE6440-2UD32-2DA1
6SE6440-2UD33-0EA1
6SE6440-2UD33-7EA1
6SE6440-2UD34-5FA1
6SE6440-2UD35-5FA1
6SE6440-2UD37-5FA1
0.16
1.1
0.33
1.9
0.50
2.7
0.75
3.6
1.0
4.7
1.5
6.4
2.0
8.3
3.0
11.7
4.0
15.6
5.0
19.7
7.5
26.5
10
34.2
15
38.0
20
50.0
25
62.0
30
71.0
40
96.0
50
114.0
60
135.0
0.9
1.7
2.3
3.0
3.9
5.5
7.4
10.4
13.6
17.5
22
28
42
54
68
80
104
130
154
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
1.3
1.7
2.2
3.1
4.1
5.9
7.7
10.2
13.2
19
26
32
38
45
62
75
90
110
145
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
4/9
MICROMASTER 440
Selection and ordering data
Rated input
current
A
hp
VT (variable torque)
Rated output
current
A
Output
kW
Rated output
current
A
Frame
size
(FS)
Weight,
approx.
kg
Order No.
hp
Rated input
current
A
150
200
250
300
350
200.0 1)
245.0 1)
297.0 1)
354.0 1)
442.0 1)
205
250
302
370
477
FX
FX
GX
GX
GX
110
116
170
174
176
6SE6440-2UD38-8FA1
6SE6440-2UD41-1FA1
6SE6440-2UD41-3GA1
6SE6440-2UD41-6GA1
6SE6440-2UD42-0GA1
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
120
3.2 2)
4.4 2)
6.9 2)
9.4 2)
12.6 2)
18.1 2)
24.9 2)
30.0 2)
35.0 2)
48.0 2)
58.0 2)
69.0 2)
83.0 2)
113.0 2)
138.0 2)
2.7
3.9
6.1
9
11
17
22
27
32
41
52
62
77
99
125
C
C
C
C
C
C
C
D
D
D
E
E
F
F
F
5.5
5.5
5.5
5.5
5.5
5.5
5.5
16
16
16
20
20
56
56
56
6SE6440-2UE17-5CA1
6SE6440-2UE21-5CA1
6SE6440-2UE22-2CA1
6SE6440-2UE24-0CA1
6SE6440-2UE25-5CA1
6SE6440-2UE27-5CA1
6SE6440-2UE31-1CA1
6SE6440-2UE31-5DA1
6SE6440-2UE31-8DA1
6SE6440-2UE32-2DA1
6SE6440-2UE33-0EA1
6SE6440-2UE33-7EA1
6SE6440-2UE34-5FA1
6SE6440-2UE35-5FA1
6SE6440-2UE37-5FA1
169.0 1)
200.0 1)
245.0 1)
297.0 1)
354.0 1)
125
150
200
250
300
178
205
250
302
370
110
132
160
200
250
1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
2.0 2)
3.7 2)
5.3 2)
8.1 2)
11.1 2)
14.4 2)
21.5 2)
24.9 2)
30.0 2)
35.0 2)
48.0 2)
58.0 2)
69.0 2)
83.0 2)
113.0 2)
1.4
2.7
3.9
6.1
9
11
17
22
27
32
41
52
62
77
99
1.5
2.2
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
Motors for
MICROMASTER 440
Catalog M 11 contains selection and ordering data for motors which are particularly suitable for operation with the
MICROMASTER 440 inverters
(see Appendix for overview).
This catalog is suitable for IEC
motors. For motors according
to US standards (NEMA)
please refer to:
http://www.sea.siemens.com/
motors
1) Supplementary conditions:
Input current at rated operating
point, applicable at short-circuit voltage of the supply
Usc 2.33 % with reference to
the inverter rated power and
rated mains operating voltage
of 400 V.
4/10
2) Supplementary conditions:
Input current at rated operating
point, applicable at short-circuit voltage of the supply
USC = 2 % with reference to the
inverter rated power and rated
mains operating voltage of
500 V without a line commutating choke.
MICROMASTER 440
Selection and ordering data
hp
Rated input
current 1)
A
VT (variable torque)
Rated output
current
A
hp
Rated input
current 1)
A
Rated output
current
A
MICROMASTER 440
with internal filter Class A 2)
Frame
Weight, Order No.
size
approx.
(FS)
kg
A
A
A
A
A
B
B
B
C
1.3
1.3
1.3
1.3
1.3
3.4
3.4
3.4
5.7
6SE6440-2AB11-2AA1
6SE6440-2AB12-5AA1
6SE6440-2AB13-7AA1
6SE6440-2AB15-5AA1
6SE6440-2AB17-5AA1
6SE6440-2AB21-1BA1
6SE6440-2AB21-5BA1
6SE6440-2AB22-2BA1
6SE6440-2AB23-0CA1
22
28
C
C
C
5.7
5.7
5.7
6SE6440-2AC23-0CA1
6SE6440-2AC24-0CA1
6SE6440-2AC25-5CA1
B
B
B
C
C
C
D
D
D
E
E
F
F
F
3.4
3.4
3.4
5.7
5.7
5.7
17
17
17
22
22
75
75
75
6SE6440-2AD22-2BA1
6SE6440-2AD23-0BA1
6SE6440-2AD24-0BA1
6SE6440-2AD25-5CA1
6SE6440-2AD27-5CA1
6SE6440-2AD31-1CA1
6SE6440-2AD31-5DA1
6SE6440-2AD31-8DA1
6SE6440-2AD32-2DA1
6SE6440-2AD33-0EA1
6SE6440-2AD33-7EA1
6SE6440-2AD34-5FA1
6SE6440-2AD35-5FA1
6SE6440-2AD37-5FA1
Output
kW
0.16
0.33
0.50
0.75
1.0
1.5
2
3
4
1.8
3.2
4.6
6.2
8.2
11.0
14.4
20.2
35.5
0.9
1.7
2.3
3.0
3.9
5.5
7.4
10.4
13.6
4.0
5.0
7.5
15.6
19.7
26.5
13.6
17.5
22.0
7.5
10.0
5.5
7.5
28.3
34.2
3.0
4.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
7.5
10.0
12.8
15.6
22.0
23.1
33.8
37.0
43.0
59.0
72.0
87.0
104.0
139.0
5.9
7.7
10.2
13.2
18.4
26
32
38
45
62
75
90
110
145
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
10
15
20
25
30
40
50
60
75
100
125
17.6
23.1
33.8
37.0
43.0
59.0
72.0
87.0
104.0
139.0
169.0
19
26
32
38
45
62
75
90
110
145
178
Motors for
MICROMASTER 440
Catalog M 11 contains selection and ordering data for motors which are particularly suitable for operation with the
MICROMASTER 440 inverters
(see Appendix for overview).
1) Supplementary conditions:
Input current at rated operating
point, applicable at short-circuit voltage of the supply
Usc = 2 % with reference to the
inverter rated power and rated
mains operating voltage of
240 V or 400 V without a line
commutating choke.
4/11
MICROMASTER 440
Options
Variant dependent options
Overview
EMC filter, Class A
Filter for inverters without an
internal filter for
3 AC 200 V to 240 V,
frame sizes A and B
3 AC 380 V to 480 V,
frame size A, FX, GX
3 AC 380 V to 480 V,
frame size A.
For inverters 15 kW to 75 kW
without filters, EMC filters of
Class B from Schaffner can be
used.
Leakage currents:
3 AC 200 V to 240 V,
frame sizes A and B
The leakage currents of the inverters with/without filter (internal/external) may exceed
30 mA. Typical values in practice are between 10 mA and
50 mA. The exact values depend on the design, environment and cable lengths. Interference-free operation with
Technical data
4/12
3 AC 380 V to 480 V
3 AC 500 V to 600 V
4.5 A/4.1 A
11.2 A/10.2 A
32.6 A/29.7 A
38.8 A/32 A
45.9 A/38 A
63.2 A/45 A
76.5 A/62 A
112.2 A/90 A
112.2 A/90 A
147.9 A/110 A
181.6 A/145 A
225 A/191 A
276 A/235 A
333 A/283 A
408 A/347 A
9.0 A/6.1 A
22.4 A/17 A
27.5 A/22 A
32.6 A/27 A
41.8 A/32 A
53 A/41 A
63.2 A/52 A
78.5 A/62 A
101 A/77 A
127.5 A/99 A
Frame sizes D to F:
The LC filters, frame sizes D
to F, are designed for
mounting upright in the control cabinet. Due to leakage
flux lines caused by physical
sources, a minimum distance of 50 mm to adjacent
modules and metal parts is
recommended.
Frame sizes FX and GX:
The sinusoidal filters, frame
sizes FX and GX, are designed for mounting upright
in the control cabinet. Due to
leakage flux lines caused by
physical sources, a minimum distance of 100 mm to
adjacent modules and metal
parts is recommended.
MICROMASTER 440
Options
Variant dependent options
1078 V
500 V/ms
4 kHz
150 Hz
shielded
unshielded
shielded
unshielded
Insulation strength
Electromagnetic compatibility
For frame sizes A to F
Installation altitude
For frame sizes A to C
Up to 2000 m:
2000 to 4000 m:
Up to 1000 m:
1000 to 4000 m:
Up to 2000 m:
2000 to 4000 m:
100 % Pn
80 % Pn
100 % Pn
80 % Pn
100 % Pn
62.5 % Pn
100 % Pn
12.5 % derating for each 1000 m
100 % Pn
7.5 % derating for each 1000 m
Footprint or suspended
upright
Top 100 mm
Bottom 100 mm
Side 100 mm
Top
Side
Input, litz wire or terminal
Output, terminals
Torque for
conductor connections
For frame sizes A to C
For frame sizes D to F
200 m
300 m
300 m
450 m
Overvoltage category III to VDE 0110
100 mm
100 mm
1U1, 1V1, 1W1
1U2, 1V2, 1W2
Terminal cross-section Torque
16 mm2
35 mm2
50 mm2
95 mm2
150 mm2
1.5 Nm to 1.8 Nm
2.0 Nm to 4.0 Nm
2.5 Nm to 5.0 Nm
3.0 Nm to 6.0 Nm
6.0 Nm to 12.0 Nm
10.0 Nm to 20.0 Nm
14.0 Nm to 31.0 Nm
7 kg
11 kg
8.5 kg to 29 kg
21 kg to 34 kg
49.5 kg to 67 kg
67 kg to 77.5 kg
135 kg
138 kg to 208 kg
4/13
MICROMASTER 440
Options
Variant dependent options
Overview
Line commutating choke
Line commutating chokes are
used to smooth voltage peaks
or to bridge commutating
dips. In addition, line commutating chokes reduce the effects of harmonics on the inverter and the power supply. If
the line impedance is < 1 %, a
line commutating choke must
be used in order to reduce the
current peaks.
In line with EN 61 000-3-2 regulations Limits for harmonic
currents with device input current 16 A per phase, there
are special aspects for drives
with 250 W to 550 W and 230 V
single-phase supplies which
can be used in non-industrial
applications (1st environment).
Brake resistors
Gland plate
Technical data
Max. permissible cable
lengths from the motor to
the inverter when using
output chokes
Note:
Operation up to 150 Hz output
frequency only!
Frame size
Output choke
(FS)
A
A
B
C
C
D to F
FX
FX
GX
GX
GX
Type
6SE6400-3TC00-4AD3
6SE6400-3TC00-4AD2
6SE6400-3TC01-0BD3
6SE6400-3TC03-2CD3
6SE6400-3TC01-8CE3
6SE6400-3TC. .-. . . .
6SL3000-2BE32-1AA0
6SL3000-2BE32-6AA0
6SL3000-2BE33-2AA0
6SL3000-2BE33-8AA0
6SL3000-2BE35-0AA0
4/14
200 m/300 m
150 m/225 m
100 m/150 m
200 m/300 m
150 m/225 m
100 m/150 m
200 m/300 m
200 m/300 m
100 m/150 m
200 m/300 m
200 m/300 m
200 m/300 m
300 m/450 m
300 m/450 m
300 m/450 m
300 m/450 m
300 m/450 m
300 m/450 m
300 m/450 m
300 m/450 m
300 m/450 m
300 m/450 m
500 V to 600 V 10 %
100 m/150 m
200 m/300 m
MICROMASTER 440
Options
Variant dependent options
Design
A maximum of two footprint
G_DA51_EN_05016d
Position 2
Position 1
Frame size
A
FX
GX
Footprint
Position 1
Position 2
Mounted on side
To the left of the inverter
(for line-side components)
A and B
EMC filter
Output choke or
LC filter
Braking resistor
EMC filter or
Line commutating choke
EMC filter or
Line commutating choke
EMC filter or
Line commutating choke or
Braking resistor
EMC filter
EMC filter or
Line commutating choke
LC filter
Output choke
D and E
F, G, FX and GX
Braking resistor
Output choke or
LC filter and/or
Braking resistor
Output choke or
LC filter and/or
Braking resistor
4/15
MICROMASTER 440
Options
Variant dependent options
3 AC 200 V
to 240 V
3 AC 380 V
to 480 V
4
3 AC 500 V
to 600 V
4/16
Output
kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
0.75
1.5
2.2
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
The inverter and the associated options have the same voltage ratings.
Inverter
without filter
hp
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
10
15
20
25
30
40
50
60
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
125
150
200
250
300
1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
6SE6440-2UC11-2AA1
6SE6440-2UC12-5AA1
6SE6440-2UC13-7AA1
6SE6440-2UC15-5AA1
6SE6440-2UC17-5AA1
6SE6440-2UC21-1BA1
6SE6440-2UC21-5BA1
6SE6440-2UC22-2BA1
6SE6440-2UC23-0CA1
6SE6440-2UC11-2AA1
6SE6440-2UC12-5AA1
6SE6440-2UC13-7AA1
6SE6440-2UC15-5AA1
6SE6440-2UC17-5AA1
6SE6440-2UC21-1BA1
6SE6440-2UC21-5BA1
6SE6440-2UC22-2BA1
6SE6440-2UC23-0CA1
6SE6440-2UC24-0CA1
6SE6440-2UC25-5CA1
6SE6440-2UC27-5DA1
6SE6440-2UC31-1DA1
6SE6440-2UC31-5DA1
6SE6440-2UC31-8EA1
6SE6440-2UC32-2EA1
6SE6440-2UC33-0FA1
6SE6440-2UC33-7FA1
6SE6440-2UC34-5FA1
6SE6440-2UD13-7AA1
6SE6440-2UD15-5AA1
6SE6440-2UD17-5AA1
6SE6440-2UD21-1AA1
6SE6440-2UD21-5AA1
6SE6440-2UD22-2BA1
6SE6440-2UD23-0BA1
6SE6440-2UD24-0BA1
6SE6440-2UD25-5CA1
6SE6440-2UD27-5CA1
6SE6440-2UD31-1CA1
6SE6440-2UD31-5DA1
6SE6440-2UD31-8DA1
6SE6440-2UD32-2DA1
6SE6440-2UD33-0EA1
6SE6440-2UD33-7EA1
6SE6440-2UD34-5FA1
6SE6440-2UD35-5FA1
6SE6440-2UD37-5FA1
6SE6440-2UD38-8FA1
6SE6440-2UD41-1FA1
6SE6440-2UD41-3GA1
6SE6440-2UD41-6GA1
6SE6440-2UD42-0GA1
6SE6440-2UE17-5CA1
6SE6440-2UE21-5CA1
6SE6440-2UE22-2CA1
6SE6440-2UE24-0CA1
6SE6440-2UE25-5CA1
6SE6440-2UE27-5CA1
6SE6440-2UE31-1CA1
6SE6440-2UE31-5DA1
6SE6440-2UE31-8DA1
6SE6440-2UE32-2DA1
6SE6440-2UE33-0EA1
6SE6440-2UE33-7EA1
6SE6440-2UE34-5FA1
6SE6440-2UE35-5FA1
6SE6440-2UE37-5FA1
6SE6400-2FA00-6AD0
EMC filter,
Class B
6SE6400-2FL01-0AB0
with low leakage currents
Line commutating
choke
6SE6400-3CC00-4AB3
6SE6400-3CC01-0AB3
6SE6400-2FL02-6BB0
with low leakage currents
6SE6400-3CC02-6BB3
6SE6400-2FB00-6AD0
6SE6400-3CC03-5CB3
6SE6400-3CC00-3AC3
6SE6400-3CC00-5AC3
6SE6400-2FA01-4BC0
6SE6400-2FB01-4BC0
6SE6400-3CC00-8BC3
6SE6400-3CC01-4BD3
6SE6400-2FA00-6AD0
6SE6400-2FB00-6AD0
6SE6400-3CC01-7CC3
6SE6400-3CC03-5CD3
6SE6400-3CC05-2DD0
6SE6400-3CC08-8EC0
6SE6400-3CC11-7FD0
6SE6400-3CC00-2AD3
6SE6400-3CC00-4AD3
6SL3000-0BE32-5AA0 *)
6SL3000-0BE34-4AA0 *)
6SL3000-0BE36-0AA0 *)
EMC filter,
Class B,
available from Schaffner
6SE6400-3CC00-6AD3
6SE6400-3CC01-0BD3
6SE6400-3CC01-4BD3
6SE6400-3CC02-2CD3
6SE6400-3CC03-5CD3
6SE6400-3CC04-4DD0
6SE6400-3CC05-2DD0
6SE6400-3CC08-3ED0
6SE6400-3CC11-2FD0
6SE6400-3CC11-7FD0
6SL3000-0CE32-3AA0
6SL3000-0CE32-8AA0
6SL3000-0CE33-3AA0
6SL3000-0CE35-1AA0
6SE6400-3CC00-4CE3
6SE6400-3CC00-8CE3
6SE6400-3CC02-4CE3
6SE6400-3CC04-4DD0
6SE6400-3CC08-3ED0
6SE6400-3CC11-2FD0
MICROMASTER 440
Options
Variant dependent options
Mains
voltage
1 AC 200 V
to 240 V
3 AC 200 V
to 240 V
3 AC 380 V
to 480 V
3 AC 500 V
to 600 V
Output
kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
0.75
1.5
2.2
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
hp
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
10
15
20
25
30
40
50
60
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
125
150
200
250
300
1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
Inverter
without filter
6SE6440-2UC11-2AA1
6SE6440-2UC12-5AA1
6SE6440-2UC13-7AA1
6SE6440-2UC15-5AA1
6SE6440-2UC17-5AA1
6SE6440-2UC21-1BA1
6SE6440-2UC21-5BA1
6SE6440-2UC22-2BA1
6SE6440-2UC23-0CA1
6SE6440-2UC11-2AA1
6SE6440-2UC12-5AA1
6SE6440-2UC13-7AA1
6SE6440-2UC15-5AA1
6SE6440-2UC17-5AA1
6SE6440-2UC21-1BA1
6SE6440-2UC21-5BA1
6SE6440-2UC22-2BA1
6SE6440-2UC23-0CA1
6SE6440-2UC24-0CA1
6SE6440-2UC25-5CA1
6SE6440-2UC27-5DA1
6SE6440-2UC31-1DA1
6SE6440-2UC31-5DA1
6SE6440-2UC31-8EA1
6SE6440-2UC32-2EA1
6SE6440-2UC33-0FA1
6SE6440-2UC33-7FA1
6SE6440-2UC34-5FA1
6SE6440-2UD13-7AA1
6SE6440-2UD15-5AA1
6SE6440-2UD17-5AA1
6SE6440-2UD21-1AA1
6SE6440-2UD21-5AA1
6SE6440-2UD22-2BA1
6SE6440-2UD23-0BA1
6SE6440-2UD24-0BA1
6SE6440-2UD25-5CA1
6SE6440-2UD27-5CA1
6SE6440-2UD31-1CA1
6SE6440-2UD31-5DA1
6SE6440-2UD31-8DA1
6SE6440-2UD32-2DA1
6SE6440-2UD33-0EA1
6SE6440-2UD33-7EA1
6SE6440-2UD34-5FA1
6SE6440-2UD35-5FA1
6SE6440-2UD37-5FA1
6SE6440-2UD38-8FA1
6SE6440-2UD41-1FA1
6SE6440-2UD41-3GA1
6SE6440-2UD41-6GA1
6SE6440-2UD42-0GA1
6SE6440-2UE17-5CA1
6SE6440-2UE21-5CA1
6SE6440-2UE22-2CA1
6SE6440-2UE24-0CA1
6SE6440-2UE25-5CA1
6SE6440-2UE27-5CA1
6SE6440-2UE31-1CA1
6SE6440-2UE31-5DA1
6SE6440-2UE31-8DA1
6SE6440-2UE32-2DA1
6SE6440-2UE33-0EA1
6SE6440-2UE33-7EA1
6SE6440-2UE34-5FA1
6SE6440-2UE35-5FA1
6SE6440-2UE37-5FA1
6SE6400-3TD00-4AD0
Output choke
Brake resistors
6SE6400-3TC00-4AD3
6SE6400-4BC05-0AA0
6SE6400-3TC01-0BD3
6SE6400-4BC11-2BA0
6SE6400-3TC03-2CD3
6SE6400-3TC00-4AD3
6SE6400-4BC12-5CA0
6SE6400-4BC05-0AA0
6SE6400-3TC01-0BD3
6SE6400-4BC11-2BA0
6SE6400-3TC03-2CD3
6SE6400-4BC12-5CA0
6SE6400-4BC13-0CA0
6SE6400-3TC05-4DD0
6SE6400-4BC18-0DA0
6SE6400-3TC08-0ED0
6SE6400-4BC21-2EA0
6SE6400-3TC15-4FD0
6SE6400-4BC22-5FA0
6SE6400-3TC00-4AD2
6SE6400-4BD11-0AA0
6SE6400-3TD01-0BD0
6SE6400-3TC01-0BD3
6SE6400-4BD12-0BA0
6SE6400-3TD03-2CD0
6SE6400-3TC03-2CD3
6SE6400-4BD16-5CA0
6SE6400-3TD03-7DD0
6SE6400-3TD04-8DD0
6SE6400-3TD06-1DD0
6SE6400-3TD07-2ED0
6SE6400-3TD11-5FD0
6SE6400-3TC05-4DD0
6SE6400-3TC03-8DD0
6SE6400-3TC05-4DD0
6SE6400-3TC08-0ED0
6SE6400-3TC07-5ED0
6SE6400-3TC14-5FD0
6SE6400-3TC15-4FD0
6SE6400-3TC14-5FD0
6SL3000-2BE32-1AA0
6SL3000-2BE32-6AA0
6SL3000-2BE33-2AA0
6SL3000-2BE33-8AA0
6SL3000-2BE35-0AA0
6SE6400-3TC01-8CE3
6SE6400-4BD21-2DA0
6SE6400-3TD15-0FD0
6SE6400-3TD18-0FD0
6SL3000-2CE32-3AA0
6SL3000-2CE32-8AA0
6SL3000-2CE33-3AA0
6SL3000-2CE34-1AA0
6SE6400-3TD01-0CE0
6SE6400-4BD22-2EA0
6SE6400-4BD24-0FA0
6SE6400-4BE14-5CA0
6SE6400-3TD02-3CE0
6SE6400-4BE16-5CA0
6SE6400-3TD02-3DE0
6SE6400-3TD03-2DE0
6SE6400-3TD03-7DE0
6SE6400-3TD04-8EE0
6SE6400-3TD06-1EE0
6SE6400-3TD07-1FE0
6SE6400-3TD10-0FE0
6SE6400-3TD11-5FE0
6SE6400-3TC03-2DE0
6SE6400-4BE21-3DA0
6SE6400-3TC06-2FE0
6SE6400-4BE21-8EA0
6SE6400-4BE24-2FA0
6SE6400-3TC08-8FE0
4/17
MICROMASTER 440
Options
Variant dependent options
Mains
voltage
1 AC 200 V
to 240 V
3 AC 200 V
to 240 V
3 AC 380 V
to 480 V
4
3 AC 500 V
to 600 V
4/18
Output
kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
0.75
1.5
2.2
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
hp
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
10
15
20
25
30
40
50
60
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
125
150
200
250
300
1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
Inverter
without filter
6SE6440-2UC11-2AA1
6SE6440-2UC12-5AA1
6SE6440-2UC13-7AA1
6SE6440-2UC15-5AA1
6SE6440-2UC17-5AA1
6SE6440-2UC21-1BA1
6SE6440-2UC21-5BA1
6SE6440-2UC22-2BA1
6SE6440-2UC23-0CA1
6SE6440-2UC11-2AA1
6SE6440-2UC12-5AA1
6SE6440-2UC13-7AA1
6SE6440-2UC15-5AA1
6SE6440-2UC17-5AA1
6SE6440-2UC21-1BA1
6SE6440-2UC21-5BA1
6SE6440-2UC22-2BA1
6SE6440-2UC23-0CA1
6SE6440-2UC24-0CA1
6SE6440-2UC25-5CA1
6SE6440-2UC27-5DA1
6SE6440-2UC31-1DA1
6SE6440-2UC31-5DA1
6SE6440-2UC31-8EA1
6SE6440-2UC32-2EA1
6SE6440-2UC33-0FA1
6SE6440-2UC33-7FA1
6SE6440-2UC34-5FA1
6SE6440-2UD13-7AA1
6SE6440-2UD15-5AA1
6SE6440-2UD17-5AA1
6SE6440-2UD21-1AA1
6SE6440-2UD21-5AA1
6SE6440-2UD22-2BA1
6SE6440-2UD23-0BA1
6SE6440-2UD24-0BA1
6SE6440-2UD25-5CA1
6SE6440-2UD27-5CA1
6SE6440-2UD31-1CA1
6SE6440-2UD31-5DA1
6SE6440-2UD31-8DA1
6SE6440-2UD32-2DA1
6SE6440-2UD33-0EA1
6SE6440-2UD33-7EA1
6SE6440-2UD34-5FA1
6SE6440-2UD35-5FA1
6SE6440-2UD37-5FA1
6SE6440-2UD38-8FA1
6SE6440-2UD41-1FA1
6SE6440-2UD41-3GA1
6SE6440-2UD41-6GA1
6SE6440-2UD42-0GA1
6SE6440-2UE17-5CA1
6SE6440-2UE21-5CA1
6SE6440-2UE22-2CA1
6SE6440-2UE24-0CA1
6SE6440-2UE25-5CA1
6SE6440-2UE27-5CA1
6SE6440-2UE31-1CA1
6SE6440-2UE31-5DA1
6SE6440-2UE31-8DA1
6SE6440-2UE32-2DA1
6SE6440-2UE33-0EA1
6SE6440-2UE33-7EA1
6SE6440-2UE34-5FA1
6SE6440-2UE35-5FA1
6SE6440-2UE37-5FA1
6SE6400-0GP00-0AA0
6SE6400-0GP00-0BA0
3NA3807
6SE6400-0GP00-0CA0
6SE6400-0GP00-0AA0
3NA3812
3NA3817
3NA3803
3NA3805
6SE6400-0GP00-0BA0
3NA3807
3NA3810
6SE6400-0GP00-0CA0
Integrated as standard
3NA3812
3NA3814
3NA3820
3NA3824
6SE6400-0GP00-0AA0
3NA3830
3NA3832
3NA3140
3NA3142
3NA3144
3NA3803
6SE6400-0GP00-0BA0
3NA3805
3NE1817-0
3NE1820-0
3NE1021-0
3NE1022-0
3NE1225-0
3NE1225-0
3NE1227-0
3NA3807
6SE6400-0GP00-0CA0
Integrated as standard
6SE6400-0GP00-0CA0
3NA3812
3NA3814
3NA3820
3NA3822
3NA3824
3NA3830
3NA3832
3NA3836
3NA3140
3NA3144
3NA3803-6
3NE1817-0
3NE1818-0
3NE1820-0
3NE1021-0
3NE1022-0
3NE1224-0
3NE1225-0
3NE1227-0
3NE1230-0
3NE1332-0
3NE1333-0
3NE1435-0
3NA3805-6
Integrated as standard
3NA3810-6
3NA3812-6
3NA3814-6
3NA3820-6
3NA3822-6
3NA3824-6
3NE1803-0
3NE1817-0
3NE1818-0
3NE1820-0
3NA3132-6
3NA3136-6
3NE1022-0
3NE1224-0
Circuit-breaker
(see Catalog LV 10)
3RV1021-1EA10
3RV1021-1HA10
3RV1021-1JA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4DA10
3RV1031-4EA10
3RV1031-4FA10
3RV1041-4JA10
3RV1021-1BA10
3RV1021-1DA10
3RV1021-1FA10
3RV1021-1GA10
3RV1021-1HA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4CA10
3RV1031-4EA10
3RV1031-4FA10
3RV1031-4HA10
3RV1042-4JA10
3RV1042-4LA10
3VL1712- . DD33- . . . .
3VL1716- . DD33- . . . .
3VL3725- . DC36- . . . .
3VL4731- . DC36- . . . .
3RV1021-1CA10
3RV1021-1DA10
3RV1021-1FA10
3RV1021-1GA10
3RV1021-1JA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4BA10
3RV1031-4EA10
3RV1031-4FA10
3RV1031-4HA10
3RV1042-4KA10
3RV1042-4MA10
3VL1712- . DD33- . . . .
3VL1716- . DD33- . . . .
3VL3720- . DC36- . . . .
3VL3725- . DC36- . . . .
3VL4731- . DC36- . . . .
3VL3725- . DC36- . . . .
3VL4731- . DC36- . . . .
3VL4740- . DC36- . . . .
3VL5750- . DC36- . . . .
3RV1021-1EA10
3RV1021-1GA10
3RV1021-1JA10
3RV1021-4AA10
3RV1021-4BA10
3RV1021-4DA10
3RV1031-4FA10
3RV1031-4HA10
3RV1042-4JA10
3RV1042-4KA10
3RV1042-4MA10
3VL1712- . DD33- . . . .
3VL1716- . DD33- . . . .
3VL3720- . DC36- . . . .
3VL3725- . DC36- . . . .
MICROMASTER 440
Options
Variant dependent options
Mains
voltage
1 AC 200 V
to 240 V
3 AC 200 V
to 240 V
3 AC 380 V
to 480 V
Mains
voltage
1 AC 200 V
to 240 V
3 AC 200 V
to 240 V
3 AC 380 V
to 480 V
Output
kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3.0
4.0
5.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
hp
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
4.0
5.0
7.5
3.0
4.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
Inverter
with internal filter
Class A
6SE6440-2AB11-2AA1
6SE6440-2AB12-5AA1
6SE6440-2AB13-7AA1
6SE6440-2AB15-5AA1
6SE6440-2AB17-5AA1
6SE6440-2AB21-1BA1
6SE6440-2AB21-5BA1
6SE6440-2AB22-2BA1
6SE6440-2AB23-0CA1
6SE6440-2AC23-0CA1
6SE6440-2AC24-0CA1
6SE6440-2AC25-5CA1
6SE6440-2AD22-2BA1
6SE6440-2AD23-0BA1
6SE6440-2AD24-0BA1
6SE6440-2AD25-5CA1
6SE6440-2AD27-5CA1
6SE6440-2AD31-1CA1
6SE6440-2AD31-5DA1
6SE6440-2AD31-8DA1
6SE6440-2AD32-2DA1
6SE6440-2AD33-0EA1
6SE6440-2AD33-7EA1
6SE6440-2AD34-5FA1
6SE6440-2AD35-5FA1
6SE6440-2AD37-5FA1
hp
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
4.0
5.0
7.5
3.0
4.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
Inverter
with internal filter
Class A
6SE6440-2AB11-2AA1
6SE6440-2AB12-5AA1
6SE6440-2AB13-7AA1
6SE6440-2AB15-5AA1
6SE6440-2AB17-5AA1
6SE6440-2AB21-1BA1
6SE6440-2AB21-5BA1
6SE6440-2AB22-2BA1
6SE6440-2AB23-0CA1
6SE6440-2AC23-0CA1
6SE6440-2AC24-0CA1
6SE6440-2AC25-5CA1
6SE6440-2AD22-2BA1
6SE6440-2AD23-0BA1
6SE6440-2AD24-0BA1
6SE6440-2AD25-5CA1
6SE6440-2AD27-5CA1
6SE6440-2AD31-1CA1
6SE6440-2AD31-5DA1
6SE6440-2AD31-8DA1
6SE6440-2AD32-2DA1
6SE6440-2AD33-0EA1
6SE6440-2AD33-7EA1
6SE6440-2AD34-5FA1
6SE6440-2AD35-5FA1
6SE6440-2AD37-5FA1
Output
kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3.0
4.0
5.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
LC filter
6SE6400-3CC00-4AB3
6SE6400-2FS02-6BB0
6SE6400-3CC02-6BB3
6SE6400-2FS03-5CB0
6SE6400-2FS03-8CD0
6SE6400-3CC03-5CB3
6SE6400-3CC01-7CC3
6SE6400-3CC03-5CD3
6SE6400-2FS01-6BD0
6SE6400-3CC01-0BD3
6SE6400-3TD01-0BD0
6SE6400-2FS03-8CD0
6SE6400-3CC01-4BD3
6SE6400-3CC02-2CD3
6SE6400-3TD03-2CD0
6SE6400-3CC01-0AB3
6SE6400-3CC03-5CD3
6SE6400-3CC04-4DD0
6SE6400-3CC05-2DD0
6SE6400-3CC08-3ED0
6SE6400-3TD03-7DD0
6SE6400-3TD04-8DD0
6SE6400-3TD06-1DD0
6SE6400-3TD07-2ED0
6SE6400-3TD11-5FD0
6SE6400-3CC11-2FD0
6SE6400-3CC11-7FD0
6SE6400-3TD15-0FD0
6SE6400-3TD18-0FD0
Brake resistors
Gland plate
6SE6400-3TC00-4AD3
6SE6400-4BC05-0AA0
6SE6400-0GP00-0AA0
6SE6400-3TC01-0BD3
6SE6400-4BC11-2BA0
6SE6400-0GP00-0BA0
6SE6400-3TC03-2CD3
6SE6400-3TC03-2CD3
6SE6400-4BC12-5CA0
6SE6400-4BC12-5CA0
6SE6400-4BC13-0CA0
6SE6400-0GP00-0CA0
6SE6400-0GP00-0CA0
6SE6400-3TC01-0BD3
6SE6400-4BD12-0BA0
6SE6400-0GP00-0BA0
6SE6400-3TC03-2CD3
6SE6400-4BD16-5CA0
6SE6400-0GP00-0CA0
6SE6400-3TC05-4DD0
6SE6400-3TC03-8DD0
6SE6400-3TC05-4DD0
6SE6400-3TC08-0ED0
6SE6400-3TC07-5ED0
6SE6400-3TC14-5FD0
6SE6400-3TC15-4FD0
6SE6400-3TC14-5FD0
6SE6400-4BD21-2DA0
Integrated as standard
6SE6400-4BD22-2EA0
6SE6400-4BD24-0FA0
4/19
MICROMASTER 440
Options
Variant dependent options
Mains
voltage
1 AC 200 V
to 240 V
3 AC 200 V
to 240 V
3 AC 380 V
to 480 V
Output
kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3.0
4.0
5.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
hp
0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
4.0
5.0
7.5
3.0
4.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
Inverter
with internal filter
Class A
6SE6440-2AB11-2AA1
6SE6440-2AB12-5AA1
6SE6440-2AB13-7AA1
6SE6440-2AB15-5AA1
6SE6440-2AB17-5AA1
6SE6440-2AB21-1BA1
6SE6440-2AB21-5BA1
6SE6440-2AB22-2BA1
6SE6440-2AB23-0CA1
6SE6440-2AC23-0CA1
6SE6440-2AC24-0CA1
6SE6440-2AC25-5CA1
6SE6440-2AD22-2BA1
6SE6440-2AD23-0BA1
6SE6440-2AD24-0BA1
6SE6440-2AD25-5CA1
6SE6440-2AD27-5CA1
6SE6440-2AD31-1CA1
6SE6440-2AD31-5DA1
6SE6440-2AD31-8DA1
6SE6440-2AD32-2DA1
6SE6440-2AD33-0EA1
6SE6440-2AD33-7EA1
6SE6440-2AD34-5FA1
6SE6440-2AD35-5FA1
6SE6440-2AD37-5FA1
4/20
3NA3805
3NA3807
3NA3812
3NA3817
3NA3810
3NA3812
3NA3814
3NA3805
l
l
3NA3807
3NA3812
3NA3814
3NA3820
3NA3822
3NA3824
3NA3830
3NA3832
3NA3836
3NA3140
3NA3144
3NE1817-0
3NE1818-0
3NE1820-0
3NE1021-0
3NE1022-0
3NE1224-0
3NE1225-0
3NE1227-0
l Use in America requires
u-listed fuses such as the
Class NON range from
Bussmann.
Circuit-breaker
(see Catalog LV 10)
3RV1021-1EA10
3RV1021-1HA10
3RV1021-1JA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4DA10
3RV1031-4EA10
3RV1031-4FA10
3RV1041-4JA10
3RV1031-4EA10
3RV1031-4FA10
3RV1031-4HA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4BA10
3RV1031-4EA10
3RV1031-4FA10
3RV1031-4HA10
3RV1042-4KA10
3RV1042-4MA10
3VL1712- . DD33- . . . .
3VL1716- . DD33- . . . .
3VL3720- . DC36- . . . .
3VL3725- . DC36- . . . .
3VL4731- . DC36- . . . .
MICROMASTER 440
Options
Variant independent options
Overview
Basic Operator Panel (BOP)
With the BOP, individual parameter settings can be made.
Values and units are shown on
a 5-digit display.
The AAOP is the Chinese version of the AOP operator panel. It has an enhanced display
and supports the operating
languages of Chinese (simplified) and English.
PROFIBUS module
CANopen module
Connection by means of a
9-pin Sub-D connector (available as an option).
DeviceNet module
For networking the inverters to
the DeviceNet fieldbus system
widely used on the American
market. A maximum transmission rate of 500 kbaud is possible. Remote control of the inverter is possible with the DeviceNet module. Remote control and operation at the inverter can be combined using an
operator panel plugged onto
the DeviceNet module.
The connection to the
DeviceNet bus system is
made using a 5-pin connector
with terminal strip.
4
Advanced Operator Panel (AOP)
4/21
MICROMASTER 440
Options
Variant independent options
Overview (continued)
Connection kit for
PC to inverter
For controlling an inverter directly from a PC if the appropriate software has been installed (e.g. STARTER). Isolated RS-232 adapter module for
reliable point-to-point connection to a PC. Includes a Sub-D
connector and an RS-232
standard cable (3 m).
For connecting a PC to an
AOP or AAOP. Offline programming of inverters and
archiving of parameter kits
possible. Includes a desktop
attachment kit for an AOP or
AAOP, an RS-232 standard
cable (3 m) with Sub-D connectors and a universal power
supply unit.
Start-up tools
STARTER
Starter is graphic start-up
software for guided start-up
for MICROMASTER 410/
420/430/440 frequency inverters under Windows NT/
2000/XP Professional. Parameter lists can be read
out, altered, stored, entered
and printed.
DriveMonitor
is a start-up software for listoriented programming of
frequency inverters. This
program executes under
Windows 98/NT/2000/ME/
XP Professional.
Both programs are included
on the Docu CD which is provided with every inverter.
Order No.
6SE6400-0BP00-0AA0
6SE6400-0AP00-0AA1
6SE6400-0AP00-0AB0
6SE6400-1PB00-0AA0
6SE6400-1DN00-0AA0
6SE6400-1CB00-0AA0
6SE6400-0EN00-0AA0
6GK1500-0FC00
6SE6400-1PC00-0AA0
6SE6400-0PA00-0AA0
6SE6400-0PM00-0AA0
6SE6400-0MD00-0AA0
6SL3072-0AA00-0AG0
4/22
MICROMASTER 440
Options
Variant independent options
Technical data
PROFIBUS module
6SE6400-1PB00-0AA0
Deflection
Acceleration
Deflection
Acceleration
Output voltage
DeviceNet module
6SE6400-1DN00-0AA0
161 mm x 73 mm x 46 mm
IP20
2 to IEC 60 664-1 (DIN VDE 0110/T1), no condensation permitted during operation
to IEC 60 068-2-6 (if module is installed correctly)
0.15 mm in the frequency range of 10 Hz to 58 Hz
19.6 m/s2 in the frequency range of 58 Hz to 500 Hz
3.5 mm in the frequency range of 5 Hz to 9 Hz
9.8 m/s2 in the frequency range of 9 Hz to 500 Hz
3K3 to IEC 60 721-3-3
Natural air cooling
10 C to +50 C (+14 F to +122 F)
25 C to +70 C (13 F to +158 F)
85 % (non-condensing)
95 %
to EN 55 011 (1991) Class A
to IEC 60 801-3 and EN 61 000-4-3
6.5 V 5 %, max. 300 mA,
internal from inverter or
24 V 10 %, max. 350 mA, external
5 V 10 %, max. 100 mA,
galvanically isolated supply
for terminating the serial interface bus or
for supplying the OLP (Optical Link Plug)
max. 12 Mbaud
4/23
MICROMASTER 440
Options
Variant independent options
Deflection
Acceleration
Deflection
Acceleration
4/24
161 mm x 73 mm x 46 mm
161 mm x 73 mm x 42 mm
IP20
2 to IEC 60 664-1 (DIN VDE 0110/T1), no condensation permitted during operation
to IEC 60 068-2-6 (if module is installed correctly)
0.15 mm in the frequency range of 10 Hz to 58 Hz
19.6 m/s2 in the frequency range of >58 Hz to 500 Hz
3.5 mm in the frequency range of 5 Hz to 9 Hz
9.8 m/s2 in the frequency range of 9 Hz to 500 Hz
3K3 to IEC 60 721-3-3
Natural air cooling
10 C to +50 C (+14 F to +122 F)
40 C to +70 C (40 F to +158 F)
25 C to +70 C (13 F to +158 F)
to EN 55 011 (1991) Class A
to IEC 60 801-3 and EN 61 000-4-3
85 % (non-condensing)
95 %
The CAN bus is supplied from the inverter
power supply
10, 20, 50, 125, 250, 500, 800 kbaud
and 1 Mbaud
5 V 5 %, 330 mA or 18 V non-regulated,
140 mA, short-circuit proof
MICROMASTER 440
Documentation
Parameter list 2)
(paper version)
Language
Multilanguage
Order No.
6SE6400-5AD00-1AP1
German
English
French
Italian
Spanish
German
English
French
Italian
Spanish
6SE6400-5AW00-0AP0
6SE6400-5AW00-0BP0
6SE6400-5AW00-0DP0
6SE6400-5AW00-0CP0
6SE6400-5AW00-0EP0
6SE6400-5BB00-0AP0
6SE6400-5BB00-0BP0
6SE6400-5BB00-0DP0
6SE6400-5BB00-0CP0
6SE6400-5BB00-0EP0
STARTER at
http://www4.ad.siemens.de/
WW/view/com/10804985/
133100
4/25
MICROMASTER 440
Dimension drawings
3 AC 380 V to 480 V
3 AC 500 V to 600 V
0.12 kW to 0.75 kW
0.37 kW to 1.5 kW
1.1 kW to 2.2 kW
2.2 kW to 4 kW
3 kW to 5.5 kW
5.5 kW to 11 kW
0.75 kW to 11 kW
Note:
The inverters must not be mounted
horizontally. But the inverters can be
mounted without lateral spacing.
73
(2.87)
ADA51-5007c
195 (7.68)
58
(2.28)
160 (6.29)
ADA51-5000e
DIN Rail
(5 149
.8
7)
147 (5.79)
173 (6.81)
ADA51-5008b
258 (10.16)
202 (7.95)
G_DA51_EN_05001d
174 (6.85)
Drill pattern
149 (5.87)
(6 172
.7
7)
138 (5.43)
309 (12.16)
ADA51-5002d
245 (9.65)
ADA51-5009b
204 (8.03)
Drill pattern
(7 195
.6
8)
174 (6.85)
185 (7.28)
4/26
MICROMASTER 440
Dimension drawings
3 AC 200 V to 240 V
3 AC 380 V to 480 V
3 AC 500 V to 600 V
7.5 kW to 15 kW
15 kW to 22 kW
15 kW to 22 kW
18.5 kW to 22 kW
30 kW to 37 kW
30 kW to 37 kW
30 kW to 45 kW
45 kW to 75 kW
45 kW to 75 kW
Note:
The inverters must not be mounted
horizontally. But the inverters can be
mounted without lateral spacing.
Drill pattern
616.4 (24.27)
650 (25.59)
Fixing with
4 x M8 bolts, 4 x M8 nuts,
4 x M8 washers
Tightening torque with washers
fitted: 3.0 Nm
Ventilation clearance required
Top and bottom: 300 mm
275 (10.82)
235 (9.25)
(9 245
.6
5)
235 (9.25)
(9 245
.6
5)
275 (10.82)
ADA51-5021b
ADA51-5020b
486 (19.13)
520 (20.47)
Drill pattern
Fixing with
4 x M8 bolts, 4 x M8 nuts,
4 x M8 washers
Tightening torque with washers fitted:
3.0 Nm
Ventilation clearance required
Top and bottom: 300 mm
Drill pattern
1110 (43.70)
1150 (45.28)
810 (31.89)
Fixing with
4 x M8 bolts, 4 x M8 nuts,
4 x M8 washers
Tightening torque with washers
fitted: 3.0 Nm
Ventilation clearance required
Top and bottom: 350 mm
300 (11.81)
350 (13.78)
(1 320
2.
6)
350 (13.78)
(1 320
2.
6)
300 (11.81)
ADA51-5023b
ADA51-5022b
850 (33.46)
Drill pattern
Fixing with
4 x M8 bolts, 4 x M8 nuts,
4 x M8 washers
Tightening torque with washers
fitted: 3.0 Nm
Ventilation clearance required
Top and bottom: 350 mm
4/27
MICROMASTER 440
Dimension drawings
Note:
The inverters must not be mounted
horizontally. But the inverters can be
mounted without lateral spacing.
3 AC 380 V to 480 V
FX
90 kW to 110 kW
GX
132 kW to 200 kW
125 125
(4.92) (4.92)
1533 (60.35)
326
(12.83)
(2 54
1. 5
46
)
Fixing with
6 x M8 bolts
6 x M8 nuts
6 x M8 washers
Tightening torque
with washers
fitted: 13.0 Nm
Ventilation clearance
required:
at top: 250 mm
at bottom: 150 mm
in front: 40 mm
G_DA51_EN_05075
1375 (54.13)
1400 (55.12)
(1 35
4. 6
06
)
G_DA51_EN_05074
326
(12.83)
125 125
(4.92) (4.92)
1508 (59.37)
125 125
(4.92) (4.92)
125 125
(4.92) (4.92)
Fixing with
6 x M8 bolts
6 x M8 nuts
6 x M8 washers
Tightening torque
with washers
fitted: 13.0 Nm
Ventilation clearance
required:
at top: 250 mm
at bottom: 150 mm
in front: 50 mm
4/28
MICROMASTER 440
Dimension drawings
EMC filter
73
56
23.5
(0.93)
149 (5.87)
120 (4.72)
24
(0.94)
(2.87)
(2.2)
185 (7.28)
156 (6.14)
38
(1.5)
4 x M5
42.5 (1.67)
219 (8.62)
232 (9.13)
ADA51-5012c
49.5 (1.95)
138
(5.43)
245 (9.65)
204 (8.03)
ADA51-5011c
213 (8.39)
174 (6.85)
174 (6.85)
187 (7.36)
ADA51-5010e
200 (7.87)
160 (6.3)
187 (7.36)
200 (7.87)
4 x M4
2 x M4
54 (2.13)
174
(6.85)
b1
n4
a1
G_DA51_XX_05103
n3
EMC filter
Class A
Type
6SL30000BE32-5AA0
0BE34-4AA0
GX/GX
0BE36-0AA0
GX
FX
270
(10.63)
270
(10.63)
310
(12.2)
360
(14.17)
360
(14.17)
400
(15.75)
b1
n3
n4
200
(7.87)
200
(7.87)
215
(8.46)
240
(9.45)
240
(9.45)
265
(10.43)
116
(4.57)
116
(4.57)
140
(5.51)
210
(8.27)
210
(8.27)
250
(9.84)
220
(8.66)
220
(8.66)
240
(9.45)
Weight,
approx
kg
12.3
12.3
19.0
4/29
MICROMASTER 440
Dimension drawings
LC filter
100
(3.9)
140
(5.51)
120
(4.72)
G_DA51_EN_05080
G_DA51_EN_05079
G_DA51_EN_05076
334 (13.15)
300 (11.81)
56
(2.2)
Drill pattern
138
(5.43)
340 (13.38)
293 (11.53)
56
(2.2)
150 (5.9)
280 (11.02)
Drill pattern
G_DA51_EN_05077
75.5
(2.97)
287 (11.3)
110
(4.3)
185 (7.28)
Drill pattern
156 (6.14)
G_DA51_EN_05081
G_DA51_EN_05078a
382 (15.04)
335 (13.19)
320 (12.6)
174 (6.85)
4/30
MICROMASTER 440
Dimension drawings
LC filter
b
LC filter
Type
for inverter
Frame size
(FS)
6SE6400-3TD03-7DD0
6SE6400-3TD04-8DD0
6SE6400-3TD06-1DD0
6SE6400-3TD02-3DE0
6SE6400-3TD03-2DE0
6SE6400-3TD03-7DE0
6SE6400-3TD07-2ED0
6SE6400-3TD04-8EE0
6SE6400-3TD06-1EE0
6SE6400-3TD11-5FD0
E/F
6SE6400-3TD15-0FD0
6SE6400-3TD18-0FD0
6SE6400-3TD07-1FE0
6SE6400-3TD10-0FE0
6SE6400-3TD11-5FE0
G_DA51_XX_05082
n2
n1
Dimensions
a
278
(10.94)
290
(11.42)
345
(13.58)
280
(11.02)
300
(11.81)
310
(12.2)
355
(13.98)
345
(13.58)
345
(13.58)
460
(18.11)
460
(18.11)
520
(20.47)
380
(14.96)
460
(18.11)
515
(20.28)
b
240
(9.45)
240
(9.45)
300
(11.81)
240
(9.45)
300
(11.81)
300
(11.81)
300
(11.81)
300
(11.81)
300
(11.81)
360
(14.17)
360
(14.17)
420
(16.54)
300
(11.81)
360
(14.17)
420
(16.54)
c
230
(9.06)
240
(9.45)
220
(8.66)
240
(9.45)
235
(9.25)
250
(9.84)
235
(9.25)
260
(10.24)
275
(10.83)
235
(9.25)
250
(9.84)
290
(11.42)
285
(11.22)
250
(9.84)
290
(11.42)
n1
115
(4.53)
125
(4.92)
120
(4.72)
125
(4.92)
133
(5.24)
145
(5.71)
145
(5.71)
160
(6.3)
171
(6.73)
125
(4.92)
140
(5.51)
173
(6.81)
171
(6.73)
140
(5.11)
173
(6.81)
n2
190
(7.48)
190
(7.48)
240
(9.45)
190
(7.48)
240
(9.45)
240
(9.45)
240
(9.45)
240
(9.45)
240
(9.45)
264
(10.39)
264
(10.39)
316
(12.44)
240
(9.45)
264
(10.39)
316
(12.44)
4/31
MICROMASTER 440
Dimension drawings
Sinusoidal filter
G_DA51_XX_00013
n1
n2
n3
n4
for inverter
Frame size (FS)
2CE32-3AA0
FX
2CE32-8AA0
GX
Dimensions
a
300
(11.81)
300
(11.81)
b
620
(24.41)
620
(24.41)
c
320
(12.6)
320
(12.6)
n1
280
(11.02)
280
(11.02)
n2
105
(4.13)
105
(4.13)
n3
225
(8.86)
225
(8.86)
n4
150
(5.91)
150
(5.91)
Weight
(max.)
kg
135.0
138.0
G_DA51_XX_00014
n1
n2
n3
n4
for inverter
Frame size (FS)
2CE33-3AA0
GX
2CE34-1AA0
GX
Dimensions
a
370
(14.57)
370
(14.57)
b
620
(24.41)
620
(24.41)
c
360
(14.17)
360
(14.17)
n1
320
(12.6)
320
(12.6)
n2
105
(4.13)
105
(4.13)
n3
225
(8.86)
225
(8.86)
n4
150
(5.91)
150
(5.91)
Weight
(max.)
kg
144.0
208.0
4/32
MICROMASTER 440
Dimension drawings
Line commutating
choke for
a
200
(7.87)
213
(8.39)
280
(11.02)
280
(11.02)
Frame size A
Frame size B
G_DA51_XX_05014e
DA51-5013e
Frame size C
(380480 V)
Frame size C
(500600 V,
0.751.5 kW)
Frame size C
(500600 V,
2.24 kW)
Frame size C
(500600 V,
5.511 kW)
Dimensions
b
75.5
(2.97)
150
(5.91)
185
(7.28)
185
(7.28)
Weight
(max.)
kg
0.8
c
50
(1.97)
50
1.3
(1.97)
50
2.3
(1.97)
50
4.4
(1.97)
280
185
50
5.0
(11.02) (7.28) (1.97)
280
185
80
6.8
(11.02) (7.28) (3.15)
Line commutating
choke for
a
520
(20.47)
650
(25.59)
DA51-5051
Dimensions
Frame size D
Frame size E
b
275
(10.83)
275
(10.83)
Weight
(max.)
kg
9.5
c
85
(3.35)
95
(3.74)
17.0
G_DA51_XX_05052
228
(8.98)
240
(9.45)
n1
n2
141
(5.55)
95
(3.74)
185
(7.28)
Weight
(max.)
kg
25.0
n1
n2
G_DA51_XX_05053
0CE33-....
GX
0CE35-....
GX
FX
248
(9.76)
248
(9.76)
269
(10.59)
255
(10.04)
255
(10.04)
275
(10.83)
n1
n2
203
(7.99)
203
(7.99)
210
(8.27)
101
(3.98)
101
(3.98)
118
(4.65)
200
(7.87)
200
(7.87)
224
(8.82)
Weight
(max.)
kg
24.0
25.0
35.0
n1
n2
4/33
MICROMASTER 440
Dimension drawings
Output chokes
c
G_DA51_XX_05050a
DA51-5049
Output choke
Type 6SE6400-
a
200
(7.87)
200
(7.87)
213
(8.39)
245
(9.65)
245
(9.65)
3TC00-4AD2
3TC00-4AD3
3TC01-0BD3
3TC01-8CE3
3TC03-2CD3
Output choke
for frame size A
6SE6400-3TC00-4AD2
6SE6400-3TC00-4AD3
b
75.5
(2.97)
75.5
(2.97)
150
(5.91)
185
(7.28)
185
(7.28)
c
110
(4.33)
50
(1.97)
70
(2.76)
150
(5.91)
80
(3.15)
Weight
(max.)
kg
1.95
0.8
3.4
9.6
5.6
Output choke
for inverter Dimensions
Type 6SE6400- Frame size
(FS)
a
b
3TC03-2DE0
D
210
225
(8.27)
(8.86)
3TC03-8DD0
D
210
225
(8.27)
(8.86)
3TC05-4DD0
D
210
225
(8.27)
(8.86)
3TC06-2FE0
F
269
300
(10.59) (11.81)
3TC07-5ED0
E
248
270
(9.76)
(10.63)
3TC08-0ED0
E
210
225
(8.27)
(8.86)
3TC08-8FE0
F
321
350
(12.64) (13.78)
3TC14-5FD0
F
321
350
(12.64) (13.78)
3TC15-4FD0
F
248
270
(9.76)
(10.63)
G_DA51_XX_05052
Dimensions
n1
n2
Output chokes
for inverters of frame sizes D, E and F
c
179
(7.05)
179
(7.05)
150
(5.91)
220
(8.66)
209
(8.23)
150
(5.91)
288
(11.34)
288
(11.34)
209
(8.23)
to DIN 41 308
n1
n2
94
176
(3.70)
(6.93)
94
176
(3.70)
(6.93)
70
176
(2.76)
(6.93)
118
224
(4.65)
(8.82)
101
200
(3.98)
(7.87)
70
176
(2.76)
(6.93)
138
264
(5.43)
(10.39)
138
264
(5.43)
(10.39)
101
200
(3.98)
(7.87)
Weight
(max.)
kg
16.0
16.1
10.7
33.9
24.9
10.4
51.5
51.5
24.0
4
a
G_DA51_XX_05053
n1
Output choke
for inverter Dimensions
Type 6SL3000- Frame size
(FS)
a
b
2BE32-1AA0
FX
285
300
(11.22) (11.81)
2BE32-6AA0
FX
315
300
(12.4)
(11.81)
2BE33-2AA0
GX
285
300
(11.22) (11.81)
2BE33-8AA0
GX
285
300
(11.22) (11.81)
2BE35-0AA0
GX
365
300
(14.37) (11.81)
c
257
(10.12)
277
(10.91)
257
(10.12)
277
(10.91)
277
(10.91)
n1
163
(6.42)
183
(7.2)
163
(6.42)
183
(7.2)
183
(7.2)
n2
224
(8.82)
224
(8.82)
224
(8.82)
224
(8.82)
224
(8.82)
Weight
(max.)
kg
60.0
66.0
62.0
73.0
100.0
n2
Output chokes
for inverters of frame sizes FX and GX
All dimensions in mm (values in brackets are in inches)
4/34
MICROMASTER 440
Dimension drawings
Brake resistors
Fig. 1:
Fig. 2:
n4
b
Fig. 3:
b
n4
b
n4
DA51-5069
DA51-5055a
n3
a
n3
a
DA51-5056
n3
c1
n1
c0
n2
Brake
resistors
Type
6SE64004BC05-0AA0
Resistor
Figure
No.
Dimensions
Ohm
for inverter
Frame size
(FS)
c0
c1
180
4BC12-5CA0
39
4BC13-0CA0
27
4BC18-0DA0
10
4BC21-2EA0
6.8
4BC22-5FA0
3.3
4BD11-0AA0
390
185
(7.28)
185
(7.28)
210
(8.27)
210
(8.27)
382
(15.04)
217
(8.54)
217
(8.54)
242
(9.53)
242
(9.53)
382
(15.04)
170
(6.69)
170
(6.69)
195
(7.68)
195
(7.68)
335
(13.19)
145
(5.71)
145
(5.71)
205
(8.07)
205
(8.07)
270
(10.63)
4BD12-0BA0
160
4BD16-5CA0
56
4BD21-2DA0
27
4BD22-2EA0
15
4BD24-0FA0
8.2
4BE14-5CA0
120
4BE16-5CA0
82
4BE21-3DA0
39
4BE21-8EA0
27
4BE24-2FA0
12
43.5
(1.71)
43.5
(1.71)
150
(5.91)
150
(5.91)
175
(6.89)
175
(6.89)
315
(12.40)
43.5
(1.71)
43.5
(1.71)
150
(5.91)
175
(6.89)
175
(6.89)
315
(12.40)
150
(5.91)
150
(5.91)
175
(6.89)
175
(6.89)
315
(12.40)
68
72
(2.83)
149
(5.87)
185
(7.28)
185
(7.28)
270
(10.63)
270
(10.63)
400
(15.75)
72
(2.83)
149
(5.87)
185
(7.28)
270
(10.63)
270
(10.63)
400
(15.75)
185
(7.28)
185
(7.28)
270
(10.63)
270
(10.63)
400
(15.75)
4BC11-2BA0
230
(9.06)
239
(9.41)
285
(11.22)
285
(11.22)
515
(20.28)
645
(25.39)
650
(25.59)
230
(9.06)
239
(9.41)
285
(11.22)
515
(20.28)
645
(25.39)
650
(25.59)
285
(11.22)
285
(11.22)
515
(20.28)
645
(25.39)
650
(25.59)
185
(7.28)
210
(8.27)
210
(8.27)
382
(15.04)
185
(7.28)
185
(7.28)
210
(8.27)
210
(8.27)
382
(15.04)
217
(8.54)
242
(9.53)
242
(9.53)
382
(15.04)
217
(8.54)
217
(8.54)
242
(9.53)
242
(9.53)
382
(15.04)
170
(6.69)
195
(7.68)
195
(7.68)
335
(13.19)
170
(6.69)
170
(6.69)
195
(7.68)
195
(7.68)
335
(13.19)
145
(5.71)
205
(8.07)
205
(8.07)
270
(10.63)
145
(5.71)
145
(5.71)
205
(8.07)
205
(8.07)
270
(10.63)
217
(8.54)
226
(8.90)
200
(7.87)
200
(7.87)
350
(13.78)
480
(18.90)
510
(20.08)
217
(8.54)
226
(8.90)
200
(7.87)
350
(13.78)
480
(18.90)
510
(20.08)
200
(7.87)
200
(7.87)
350
(13.78)
480
(18.90)
510
(20.08)
56
(2.20)
138
(5.43)
230
(9.06)
230
(9.06)
315
(12.40)
315
(12.40)
435
(17.13)
56
(2.20)
138
(5.43)
230
(9.06)
315
(12.40)
315
(12.40)
435
(17.13)
230
(9.06)
230
(9.06)
315
(12.40)
315
(12.40)
435
(17.13)
Weight
(max.)
kg
1.0
1.6
3.8
3.8
7.4
10.6
16.7
1.0
1.6
3.8
7.4
10.6
16.7
3.8
3.8
7.4
10.6
16.7
4/35
MICROMASTER 440
Notes
4/36
MICROMASTER
410/420/430/440
Appendix
A/2
A/2
Certificates
A/4
A/6
A/7
A/7
A/8
Demonstration case
A/8
A/9
Training
A/10
A/11
A/12
Overview of motors
A/13
A/14
A/15
Online services
A/16
A/18
Subject index
A/19
A/20
A/1
MICROMASTER 410/420/430/440
Appendix
Certificates
A/2
MICROMASTER 410/420/430/440
Appendix
Certificates (continued)
Legend for EC declaration of conformity:
The named product is in conformity with the requirements of the
following European Directive:
73/23/EEC Council Directive on the approximation of the laws of the
Member States relating to electrical equipment for use
within certain voltage limits, amended by Council Directive
RL 93/68/EEC
Conformity with the requirements of these Directives is testified by
complete adherence to the following standards:
The named product is intended for fitting in another machine.
Commissioning is prohibited until such time as the end product has
been proved to conform to the provisions of Directive 98/37/EC.
This declaration does not give assurance of properties within the
meaning of product liability. The safety instructions provided in the
product documentation must be observed.
A/3
MICROMASTER 410/420/430/440
Appendix
A/4
Category C3:
Drive systems for rated
voltages of < 1000 V,
solely for use in the second environment. Warning information must be
provided.
Category C4:
Drive systems for rated
voltages of 1000 V or
for rated currents of
400 A or for use in
complex systems in the
second environment. An
EMC plan must be drawn
up.
In the EMC product standard EN 61 800-3, limits for
conducted interference voltages and radiated interference are also indicated for
the so-called second environment (= industrial power
supply systems which do
not supply households).
These limits are lower than
the limits of filter class A according to EN 55 011. The
use of unfiltered inverters in
an industrial environment is
permissible provided they
are part of a system that is
equipped with line filters on
the higher-level infeed side.
With MICROMASTER,
power drive systems (PDS)
which comply with EMC
product standard
EN 61 800-3 can be installed (see the installation
instructions in the product
documentation). The table
entitled Overview of
MICROMASTER components and PDS categories
and the MICROMASTER
ordering documents show
which components the respective PDS installation
supports directly.
MICROMASTER 410/420/430/440
Appendix
Electromagnetic
compatibility
EMC phenomenon
Standard/test
Emitted interference
EN 61 800-3
ESD immunity
EN 61 000-4-2
Immunity to electrical
fields
EN 61 000-4-3
Immunity to burst
interference
EN 61 000-4-4
Surge immunity
EN 61 000-4-5
Immunity to RFI
emissions, conducted
EN 61 000-4-6
UL listing
Category C1
Unfiltered devices plus external Class B filter with low leakage currents
Category C2
Devices with an integrated Class B filter
Devices with an integrated Class B filter
or devices with an integrated Class A filter
or devices with an integrated Class A filter
plus external supplementary filter Class B
plus external supplementary filter Class B
or devices with an integrated Class A filter
or devices with an integrated Class A filter
plus warning information
or unfiltered devices plus external Class A
filter
or unfiltered devices plus external Class A
Note: The requirements of EN 61 800-3 are
filter plus warning information
considerably exceeded if Class B filters are
used.
Category C3
Devices with integrated Class A filter
or unfiltered devices plus external Class A filter
Warning information is necessary.
Note: The requirements of EN 61 800-3 are considerably exceeded if Class A filters are used.
Category C4
Unfiltered devices plus external Class A filter
An EMC plan must be drawn up.
Note: The requirements of EN 61 800-3 are considerably exceeded if Class A filters are used.
Second environment
(industrial)
Relevant criteria
Limit value
30 MHz to 1 GHz
4 kV
2 kV
10 V
A/5
MICROMASTER 410/420/430/440
Appendix
SETUP program
For installing the software
in the STEP 7 environment
Supply format
Documentation
Order No.
CD-ROM
6SW17005JA003AA0
CD-ROM
6SW17005JA003AA4
6SW17005JA003AA1
CD-ROM
6SW17005JC003AA0
CD-ROM
6SW17005JC003AA4
6SW17005JC001AC0
6SW17005JD002AA0
CD-ROM
6SW17006JD00-0AA0
CD-ROM
6SW17006JD000AA4
6SW17005JD001AC0
A/6
MICROMASTER 410/420/430/440
Appendix
Drive ES Basic
Update service for single license
Update service for copy license
Drive ES SIMATIC
Update service for single license
Drive ES PCS7
Update service for single license
Order No.
6SW17000JA000AB2
6SW17000JA001AB2
6SW17000JC000AB2
6SW17000JD000AB2
A/7
MICROMASTER 410/420/430/440
Appendix
Demonstration case
SIDEMO demonstration case system
The SIDEMO range of modular
demonstration case systems
also includes cases for the
MICROMASTER inverters.
The MICROMASTER demonstration cases can be operated on 230 V supplies on their
own or together with other
demonstration systems such
as LOGO!, SIMATIC S7-200,
SITOP DC-UPS.
Order No.
MICROMASTER 410
including OP operator panel
MICROMASTER 420
including BOP operator panel
MICROMASTER 440
including BOP operator panel
MICROMASTER 440
including BOP operator panel
the motor is equipped with a load unit
MICROMASTER 440
including BOP operator panel and pulse encoder evaluation module
the motor is equipped with an encoder and a load unit
6AG1062-1AA08-0AA0
Weight, approx.
kg
10
6AG1062-1AA02-0AA0
10
6AG1062-1AA02-1AA1
10
6AG1062-1AA06-0AA0
10
6AG1062-1AA07-0AA0
10
Further information, e.g. 110 V versions, is available on the Internet at: http://www.siemens.de/sidemo
Temperature
Weight
Torque
Power
A/8
Note:
For kW and hp specifications
in the Selection and Ordering
tables, we do not use calculated hp values but the corresponding standardized hp
motor ratings.
MICROMASTER 410/420/430/440
Appendix
Training
Training variety
With a total of some
300 participant-based
courses, we can provide training for the entire range of
products and a large number
of system solutions. Remote
learning services, self-teach
software and moderated online seminars complement our
traditional training offer.
Customer proximity
Top trainers
Our trainers are skilled specialists with extensive experience of training provision. The
designers of our courses are
directly involved in product
development and forward
their knowledge directly to our
trainers.
A firm basis in practice
As our trainers have direct experience of practical applications, they are able to render
their theoretical knowledge
with real plausibility. However,
as we all know that any theory
has its gray areas, we prioritize practical exercises, and
allocate up to half of the
course program to them. This
means that you can apply
what you have learned immediately in everyday activities.
We use state-of-the-art customized training equipment.
Once you have completed
your training with us, you will
feel ready for anything.
Language
German
Order No.
E86060-K6850-A101-B6
German
E86060-P6850-A101-D2
English/
German
E86060-D6850-A100-C4-7400
English/
German
E86060-K6899-A101-B5-7400
A/9
MICROMASTER 410/420/430/440
Appendix
Main features
Rated outputs
Input voltage
Total module width
Mains frequency
Overload capacity
Output frequency
Pulse frequency
Skip frequency
range
Efficiency
Interfaces
Standards
complied with
Functional safety
Degree of
protection
SIMATIC ET 200S FC
With its wide range of possibilities, the ET 200S FC makes it possible for the distributed ET 200S system to be used for
new applications in the area of drive technology, where infinite speed control of inductive motors is required. This frequency
converter can handle simple drive tasks (frequency control) as well as complex tasks with vector control. Integrated safety
functions enable drive solutions without high overheads, even in parts of an installation where potential hazards exist.
750 W, 2.2 kW, 4.0 kW
3 AC 380 V to 480 V +10 % 15 %
Control module + power unit 80 mm up to 750 W rated output, otherwise 145 mm
47 to 63 Hz
Overload current 1.5 x rated output current (i.e. 150% overload) for 60 s, cycle time 300 s
Overload current 2 x rated output current (i.e. 200% overload) for 3 s, cycle time 300 s
0 Hz to 650 Hz
8 kHz (standard), 2 kHz to 16 kHz (in 2 kHz steps)
1, programmable
96 %
PROFIBUS or PROFINET interface via the ET 200S backplane bus
Control of the integrated safety functions via PROFIsafe (PM-D F PROFIsafe) or terminals (PM-D F X1)
RS232 interface with USS protocol for start-up at PC with STARTER start-up software
Slot for an optional micro-memory card for uploading and downloading parameter settings
PTC/KTY84 interface for motor monitoring
Tachometer interface (Sub-D connector) for unipolar HTL incremental encoder
UL, cUL, CE and C-tick, low-voltage directive 73/23/EEC, EMC directive 89/336/EEC
Control board with integrated safety functions in accordance with Category 3 of EN 954-1 or in accordance
with SIL 2 of IEC 61508:
Safe stop
Safe braking ramp
Safely reduced speed
The safety functions Safely reduced speed and Safe braking ramp are certified for encoderless induction motors
these safety functions are not approved for pull-through loads such as found in hoisting gear and unwinding units.
IP20
A
SIMATIC ET 200S FC control boards
A/10
MICROMASTER 410/420/430/440
Appendix
Main features
Output range
Supply voltages
Network types
Mains frequency
Output frequency
Control method
Fixed frequencies
Skip frequency
ranges
Digital inputs
Analog input
(for the analog version)
Digital output
Communication
interface
(for USS version)
Software
functions
Protection
functions
Connectable
motors
Degree of
protection
Type of cooling for
0.75 kW inverters
> 0.75 kW inverters
Standards
complied with
http://www.siemens.com/
sinamics-g110
SINAMICS G110
As a versatile drive for small outputs, the frequency inverter of the SINAMICS G110 inverter chassis units can be used for
a wide range of industrial drive applications with variable speeds. The especially compact SINAMICS G110 inverter works
with voltage-frequency control (V/f) and is the ideal frequency inverter in the lower output and performance range of the
SINAMICS family of products. The inverter is available in three frames for connection to single-phase power supply systems.
0.12 kW to 3.0 kW
1 AC 200 V to 240 V, 10 %
IT, TN, TT
50/60 Hz
0 Hz to 650 Hz
V/f control, linear (M~n)
V/f control, quadratic (M~n2)
V/f control, programmable
3, programmable
1, programmable
3 programmable digital inputs 24 V DC
1 analog input for setpoints from 0 V to 10 V, scalable or usable as 4th digital input
1 digital output 24 V DC
RS485 serial interface for operation with USS protocol
Ribbed heat sink with convection cooling; version with flat heat sink also available
Internal air cooling (integrated fan)
CE, UL, cUL, c-tick
Examples
SINAMICS G110 inverter chassis units
A/11
MICROMASTER 410/420/430/440
Appendix
Overview of motors
Siemens motors are ideally
matched to the
MICROMASTER inverters.
The table provides an overview of the most common
types of motors from Siemens.
Main
characteristics
Squirrel-cage motors
Motors with gray cast iron casing
1LG6
1LG4
*)
*)
Rating (4-pole)
Speeds
18.5 200 kW
3000 rpm
1500 rpm
1000 rpm
750 rpm
230/400 V d/*
400/690 V d/*
18.5 200 kW
Voltage (at 50 Hz
if not specified
otherwise)
Size
Design
Casing
Degree of
protection
180 315
IM B3
IM B5
IM V1
IM B14 (Sizes 100 to 160)
IM B35
Gray cast iron
IP55 (IP65, IP56)
1LA9
*)
1LA7
0.06 15 kW
3000 rpm
1500 rpm
1000 rpm
750 rpm
230/400 V d/*
400/690 V d/*
18.5 45 kW
56 160
180 225
0.06 30 kW
3000 rpm
1500 rpm
1000 rpm
0.08 40 hp
3600 rpm
1800 rpm
1200 rpm
400/690 V d/*
230/400 V d/*
400/690 V d/*
60 Hz 460 d*
315 450
IM B3
IM V1
IM B35
56 200
IM B3
IM B5
IM V1
IM B14 (Sizes 56 to 160)
IM B35
Aluminum
IP55 (IP65, IP56)
IP55 (IP56)
A
*) 1.1 kW to 90 kW, 2-pole and 4-pole
1LA9
EPACT
250 1000 kW
A/12
Efficiency class
1LA5
*)
MICROMASTER 410/420/430/440
Appendix
Geared motors
Helical gears Flat gears
2KG31,
2KG36,
2KG41,
2KG32,
2KG46
2KG42
0.09 kW to 45 kW
Voltage range
Frame sizes/
unit sizes
Types of
construction
3 AC 380 V to 480 V
CS B
CS C
Degree of
protection
Other technical
features
IP65
Main features
Output range
71 100
90/100
IM B 3
IM B 5
IM V 1
(without protective
roof)
IM V 1
(with protective roof)
IM B 14
(with normal flange)
IM B 14
(with special flange)
IM B 35
IP55
V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
FCC (flux current control)
Internal PI controller
3 digital inputs
1 analog input
1 relay output
Compound braking for controlled
rapid braking
NEW: ECOFAST versions with plug-in connectors for power-supply, communication
interface and motor connections in order to
enable fast and problem-free information
exchange in applications where time is a
critical factor. The ECOFAST versions are
completely compatible with the ECOFAST
technology systems.
Footprint
type of construction
Flange
type of construction
http://www.siemens.com/
combimaster
http://www.siemens.com/
gearedmotors
Helical bevel
gears
2KG33,
2KG43
2KG35
0.09 kW to
1.5 kW
63 132
63 90
Housing
made of
aluminum or
gray cast iron
Torque
120
1590 Nm
Housing
made of
die-cast
aluminum
Torque
50
185 Nm
Housing
made of
aluminum or
gray cast iron
Torque
150
20000 Nm
Housing
made of
aluminum or
gray cast iron
Torque
130
20000 Nm
A
Examples
MICROMASTER
Examples
COMBIMASTER
Examples
Geared motors
A/13
MICROMASTER 410/420/430/440
Appendix
A/14
MICROMASTER 410/420/430/440
Appendix
A/15
MICROMASTER 410/420/430/440
Appendix
Service On Site
With Service On Site we offer
services for startup and maintenance, essential for ensuring
system availability.
In Germany
0180 50 50 444 1)
Online Support
The comprehensive information
system available round the
clock via Internet ranging from
Product Support and Service &
Support services to Support
Tools in the Shop.
http://www.siemens.com/
automation/service&support
In Germany
0180 50 50 446 1)
Technical Support
Competent consulting in technical questions covering a wide
range of customer-oriented services for all our products and
systems.
Technical Consulting
Support in the planning and
designing of your project from
detailed actual-state analysis,
target definition and consulting
on product and system questions right to the creation of the
automation solution. 1)
A
1) For country-specific telephone numbers go to our Internet site at:
http://www.siemens.com/automation/service&support
A/16
MICROMASTER 410/420/430/440
Appendix
Order no.
200
6ES7 997-0BA00-0XA0
500
6ES7 997-0BB00-0XA0
1000
6ES7 997-0BC00-0XA0
10000
6ES7 997-0BG00-0XA0
The Automation Value Card is an integral component of the comprehensive service concept with which Siemens Automation and
Drives will accompany you in each phase of your automation
project.
http://www.siemens.com/automation/service&support
It doesnt matter whether you want just specific services from our
Technical Support or want to purchase high-quality Support
Tools in our Online Shop, you can always pay with your Automation Value Card. No invoicing, transparent and safe. With your
personal card number and associated PIN you can view the
state of your account and all transactions at any time.
Priority
24 h
Extended
Tools that can be used directly for configuration, analysis and testing
Applications
Functions &
Samples
A/17
MICROMASTER 410/420/430/440
Appendix
Subject index
MICROMASTER
MICROMASTER
410
420
430
440
Page
Page
Page
Page
A
AAOP (operator panel)
AOP (operator panel)
Applications
Assignment table for options
Automation Value Card
1/2
0/8
A/17
2/16
2/16
2/2
0/8
A/17
3/2
0/8
A/17
4/22
4/22
4/2
0/8
A/17
B
BOP (operator panel)
BOP-2 (operator panel)
Brake resistor (option)
2/16
-
3/16
-
4/22
4/17
C
CANopen module
CE marking
Certificates
Chokes (options)
Circuit diagrams
Circuit-breaker (option)
COMBIMASTER 411 (overview)
Communications modules
Compliance with standards
Conditions of sale and delivery
A/4
A/2
1/8
1/4
1/9
A/13
A/4
A/20
2/16
A/4
A/2
2/13
2/4
2/14
A/13
2/16
A/4
A/20
3/16
A/4
A/2
3/14
3/4
3/14
A/13
3/16
A/4
A/20
4/22
A/4
A/2
4/17
4/4
4/18
A/13
4/22
A/4
A/20
D
Demonstration case
Derating data
Description (inverter)
Description (options)
Design
DeviceNet module (option)
Dimension drawings
Docu pack
Documentation
Drive ES
Drive ES software
DriveMonitor
A/8
1/6
1/2
1/8
1/2
1/10
1/9
A/6
A/6
1/9
A/8
2/7
2/2
2/9
2/2
2/16
2/18
2/17
2/17
A/6
A/6
2/15
A/8
3/7
3/2
3/10
3/2
3/16
3/19
3/18
3/18
A/6
A/6
3/16
A/8
4/7
4/2
4/12
4/2
4/22
4/26
4/25
4/25
A/6
A/6
4/22
E
Electromagnetic compatibility
EMC filter (option)
Environment, resources and recycling
Export regulations
A/5
1/8
A/2
A/20
A/5
2/12
A/2
A/20
A/5
3/14
A/2
A/20
A/5
4/16
A/2
A/20
F
Features
Filter (option)
Fuses (options)
1/3
1/8
1/9
2/3
2/12
2/14
3/3
3/14
3/14
4/3
4/16
4/18
G
Geared motors (overview)
General circuit diagram
Getting Started Guide
A/13
1/4
1/9
A/13
2/4
2/17
A/13
3/4
3/18
A/13
4/4
4/25
I
Installation height (derating)
Integration with Drive ES
International standards
Internet (online services)
L
LC filter
Line commutating chokes
(option)
A/18
1/7
A/6
1/2
A/15
2/7
A/6
2/2
A/15
3/8
A/6
3/2
A/15
4/8
A/6
4/2
A/15
2/13
3/14
4/17
1/8
2/13
3/14
4/16
410
420
430
440
Page
Page
Page
Page
M
Main characteristics
Mechanical features
MICROMASTER 411 (overview)
Motors (overview)
1/2
1/3
A/13
A/12
2/2
2/3
A/13
A/12
3/2
3/3
A/13
A/12
4/2
4/3
A/13
A/12
N
Notes on ordering
A/19
A/19
A/19
A/19
O
Online services
OP (operator panel)
Operating instructions
Operating temperature (derating)
Operator panels
Options
Ordering data (inverter)
Ordering data (options)
Output chokes (option)
Overview
A/15
1/9
1/9
1/9
1/8
1/7
1/8
0/6
A/15
2/17
2/7
2/16
2/9
2/8
2/12
2/13
0/6
A/15
3/18
3/7
3/16
3/10
3/9
3/14
3/14
0/7
A/15
4/25
4/8
4/22
4/12
4/9
4/16
4/17
0/7
1/9
1/3
1/3
2/17
2/3
2/16
2/3
3/18
3/3
3/16
3/3
4/25
4/3
4/22
4/3
1/6
2/7
3/7
4/22
4/7
1/7
2/8
3/9
4/9
1/8
0/6
A/16
A/8
A/14
1/9
1/9
A/16
2/11
0/6
A/16
A/8
A/14
2/16
2/15
A/16
3/14
0/7
A/16
A/8
A/14
3/14
3/16
3/16
A/16
4/16
0/7
A/16
A/8
A/14
4/17
4/22
4/22
A/16
T
Technical data (inverter)
Technical data (options)
Terminal connection diagram
Terminal connection plates (option)
Training
1/6
1/5
A/9
2/6
2/10
2/5
2/14
A/9
3/6
3/10
3/5
3/14
A/9
4/6
4/12
4/5
4/18
A/9
U
UL listing
Update service for Drive ES
A/5
A/7
A/5
A/7
A/5
A/7
A/5
A/7
V
Variant dependent options
Variant independent options
1/8
1/9
2/12
2/16
3/14
3/16
4/16
4/22
P
Parameter list
Performance features
PROFIBUS module (option)
Protection features
Pulse encoder evaluation
module (option)
Pulse frequency (derating)
S
Selection and ordering data
(inverter)
Selection and ordering data
(options)
Selection guide
Service and support
SIDEMO (demonstration case system)
Siemens contacts worldwide
Sinusoidal filter
STARTER
Start-up tools
Support
MICROMASTER 410/420/430/440
Appendix
Notes on ordering
Versions/variants
MICROMASTER
410
420
430
440
Page
Page
Page
Page
3NA3...
1/8
2/14
3/14, 3/15
4/18, 4/20
3NE1...
3/14, 3/15
4/18, 4/20
3RV10..
1/8
2/14
3/14, 3/15
4/18, 4/20
3VL....
3/14, 3/15
4/18, 4/20
6AG1062-1AA..
A/8
A/8
A/8
6ES7997-0B...
A/17
A/17
A/17
A/17
6GK1500-0FC00
2/16
3/16
4/22
6SE6400-0AP00-0AA1
6SE6400-0AP00-0AB0
6SE6400-0BE00-0AA0
6SE6400-0BP00-0AA0
6SE6400-0DR00-0AA0
6SE6400-0EN00-0AA0
6SE6400-0GP00-0.A0
6SE6400-0MD00-0AA0
6SE6400-0P.00-0AA0
6SE6400-0SP00-0AA0
6SE6400-1CB00-0AA0
6SE6400-1DN00-0AA0
6SE6400-1P.00-0AA0
1/9
1/9
1/9
-
2/16
2/16
2/16
2/14
2/16
2/16
2/16
2/16
2/16
3/16
3/14
3/16
3/16
3/16
3/16
4/22
4/22
4/22
4/22
4/18, 4/19
4/22
4/22
4/22
4/22
4/22
6SE6400-2FA0.
6SE6400-2FB0.
6SE6400-2FL0.
6SE6400-2FS0.
1/8
-
2/12
2/12
2/13
2/12
3/15
4/16
4/16
4/16
4/19
6SE6400-3CC..
6SE6400-3TC..
6SE6400-3TD..
1/8
-
2/13
2/13
2/13
3/14, 3/15
3/14, 3/15
3/14, 3/15
4/16, 4/19
4/17, 4/19
4/17, 4/19
6SE6400-4B...
4/17, 4/19
6SE6400-5....
1/9
2/17
3/18
4/25
6SE6410-2BB..
6SE6410-2UA..
6SE6410-2UB..
1/7
1/7
1/7
6SE6420-2AB..
6SE6420-2AC..
6SE6420-2AD..
6SE6420-2UC..
6SE6420-2UD..
2/8
2/8
2/8
2/8
2/8
6SE6430-2AD..
6SE6430-2UD..
3/9
3/9
6SE6440-2AB..
6SE6440-2AC..
6SE6440-2AD..
6SE6440-2UC..
6SE6440-2UD..
6SE6440-2UE..
4/11
4/11
4/11
4/9
4/9
4/10
6SL3000-0BE3.
6SL3000-0CE3.
6SL3000-2BE..
6SL3000-2CE..
3/14
3/14
3/14
3/14
4/16
4/17
4/17
4/16
6SL3072-0AA0.
1/9
2/16
3/16
4/22
6SW1700-0J...
6SW1700-5J...
A/7
A/6
A/7
A/6
A/7
A/6
A/7
A/6
6ZB5310-0EP30-0BA2
6ZB5310-0K...
A/17
A/20
A/17
A/20
A/17
A/20
A/17
A/20
A/19
MICROMASTER 410/420/430/440
Appendix
Export regulations
The products listed in this catalog / price list may be subject to
European / German and/or US export regulations.
Therefore, any export requiring a license is subject to approval
by the competent authorities.
According to current provisions, the following export regulations
must be observed with respect to the products featured in this
catalog / price list:
AL
ECCN
Even without a label or with an AL: N or ECCN: N, authorization may be required due to the final destination and purpose for
which the goods are to be used.
The deciding factors are the AL or ECCN export authorization
indicated on order confirmations, delivery notes and invoices.
Errors excepted and subject to change without prior notice.
A&D/VuL/En 17.03.05
Responsible for
Technical contents:
Siemens AG, A&D SD S MP, Erlangen
General editing:
Siemens AG, A&D PT 5, Erlangen
Siemens AG
Automation & Drives
Standard Drives
Postfach 3180
91050 ERLANGEN
GERMANY
A/20
Catalogs of the
Automation and Drives Group (A&D)
Further information can be obtained from our branch offices listed
in the appendix or at www.siemens.com/automation/partner
Automation and Drives
Interactive catalog on CD-ROM
Catalog
Catalog
LV 10
CA 01
LV 30
LV 60
NC 60
LV 70
LV 90
PM 10
Drive Systems
Variable-Speed Drives
SINAMICS G130 Drive Converter Chassis Units,
SINAMICS G150 Drive Converter Cabinet Units
D 11
D 11.1
D 21.2
D 21.3
DC Motors
DA 12
DA 21.1
DA 21.2
DA 22
FI 01
MP 12
MP 20
MP 31
DA 45
WT 01
DA 48
WT 02
DA 51.2
PA 10
DA 51.3
PA 11
DA 63
DA 65.10
PA 20
DA 65.11
DA 65.3
ST 45
DA 65.4
ST 50
ST 70
M 11
NC 60
Low-Voltage Three-Phase-Motors
HE 1
ET A1
ET A3
ET A5
ET B1
ET D1
ET G1
FS 10
ST 80
IK PI
ST PCS 7
ST PCS 7.A
pc-based Automation
ST PC
ST DA
MP 35
MP 35.1/.2
Systems Engineering
Power supplies SITOP power
KT 10.1
KT 10.2
System Solutions
Applications and Products for Industry are part of the
interactive catalog CA 01
PLT 112
Seite 1
Siemens AG
Automation and Drives
Standard Drives
Postfach 31 80
91050 ERLANGEN
GERMANY
www.siemens.com/micromaster
Catalog DA 51.2
2005/2006
Seite 2