You are on page 1of 6

INTERNAL MECHANICAL SERVICES INSTALLATION

S/NO DESCRIPTION
INTERNAL PLUMBING
INSTALLATION
SANITARY FIXTURES SHALL
INCLUDE SUPPLY AND FIX
COMPLETELY THE FOLLOWING,
INCLUDING ALL JOINTS TO COLD
WATER SUPPLY AND DISCHARGE
1
PIPES WITH TRAPS
Low level water closet suite with
s-trap of white "Twyford" type or
other equal and approved
comprising pan, plastic cover,
flushing cistern, flush bend and
concealed fixing brackets
including plugging and screwing
A
pan and bracket
400X365mm Twyford type or
other equal and approved
lavatory wash hand basin
complete with pair 13mm pillar
tap, 32mm waste fitting with
plug chain and stay, 32mm trap
and pair cantilever bracket
including plugging and screwing
B
brackets

Armitage shank ceramic


laboratory through 540 X 450
X370mm deep complete with top
head and water fitting
Brick model B-6699 Toilet roll
holder

Automatic soap dispenser

QYT

12

UNI
T

No.

RATE

TOTAL

19,000.00

228,000.0
0

12

No.

10,000.00

120,000.0
0

138

No.

15,000.00

2,070,000

12

No.

1,200.00

12

No.

1,300.00

14,400.00
156,000.0
0

2
A
B
C
D
E
F
G
H
J
K

Pilkington mirror or approved


equal with clip and screwed for
mounting to wall
TO COLLECTION

12

No.

2,500.00

30,000.00
2,618,400

65
9
5
4
12
592
75
23
26
12

No.
No.
No.
No.
No.
Mtr.
No.
No.
No.
No.

260.00
360.00
350.00
330.00
280.00
140.00
165.00
165.00
165.00
450.00

16,900.00
3,240.00
1,750.00
1,320.00
3,360.00
82,880.00
12,375.00
3,795.00
4,290.00
5,400.00

WASTE/SANITARY PIPE WORKS


UNPLASTICATED PVC PIPES TO
BS4515 WITH SOLVENT WELDED
JOINT

100mm diameter pipe


100mm diameter bend
100mm diameter Y junction
100mm diameter Tee
100mm diameter pan connector
32mm diameter pipe
32mm diameter bend
32mm diameter Y junction
32mm diameter Tee
32mm diameter floor drain

135,310.0
0

TO COLLECTION

A
B

RAIN WATER INSTALLATION


Unplastized pvc rain water pipes
and fittings to BS 4514 with ring
seal joints
100mm diameter rain pipes
bedded in concrete column
100mm diameter bend
Fulbora cast iron roof and
balcony outlet complete with
grating including building into
concrete
TO COLLECTION

65
24

mtr. 260.00
No. 360.00

16,900.00
8,640.00

No.

9,600.00
35,140.00

1,200.00

175
38
23
29
220
18
12

No.
No.
No.
No.
No.
No.
No.

550.00
105.00
105.00
150.00
440.00
75.00
75.00

96,250.00
3,990.00
2,415.00
4,350.00
96,800.00
1,350.00
900.00

H
J
K

COLD WATER SUPPLY PIPES,


TIGER PRESSURE PIPES TO BS
4514 WITH SOLVENT WELDED
JOINTS
19mm diameter pipe
19mm diameter bend
19mm diameter Tee
19X19X13mm reducing Tee
13mm diameter pipe
13mm diameter bend
13mm diameter Tee
13mm diameter flexible
connector
19mm diameter non-return valve
19mm diameter gate valve

155
1
4

No.
No.
No.

200.00
1,200.00
1,500.00

13mm diameter gate valve

155

No.

1,100.00

31,000.00
1,200.00
6,000.00
170,500.0
0

4
A
B
C
D
E
F
G

414,755.0
0

TO COLLECTION

INTERNAL FIRE FIGHTING


INSTALLATION HOSE REEL
SYSTEM
50mm Diameter pipe
50mm Diameter bend
50x50x38mm Reducer Tee
38mm cold water supply hose
reel bedded in wall

25mm Diam. Landing valve

5
A
B
C

50
8
1

Mtr.
No.
No.

1,350.00
380.00
700.00

67,500.00
3,040.00
700.00

25

Mtr.

400.00

10,000.00

No.

19,000.00

76,000.00

F
G

Recessed Fire Hose Reel as


manufactured by 'NORSEN TYPE
'S' or other equal and approved
designed to withstand a pressure
of 1035KN/m2 consisting of steel
plate ,nylon reel bearing, actual
axle and water ways, plated
nylon roller guides brackets
,screw down brass stop valve to
B.S.1010,nylon off jet spray
action nozzle and 19mm
diameter bore 30m long rubber
reel hose ,all housed in cabinet
with full length recessed and
hand grip in the door, complete
with landing valve outlet
6kg all-purpose carbon dioxide
fire extinguisher[ANGUS]
9kg ABC Multipurpose dry
powder fire extinguisher
complete with charge and wall
mounted brackets fixed 1050mm
above floor level

No.

90,000.00

12

No.

20,000.00

360,000.0
0
240,000.0
0

22,000.00

264,000.0
0

12

No.

TO COLLECTION

6
A.
B

C.

GAS INSTALLATION
50mm diam.UPVC sleeve for gas
hose
13mm diam. Gas Hose
50kg Gas Cylinder complete with
guage and all installation
accessories such as clips etc.to
be located in fire resisting
chamber with high and low level
ventilations

1,020,540

125
185

mtr 1,350.00
Mtr.. 450.00

168,000.0
0
83,250.00

No.

171,000.0
0

28,500.00

D.
E.
F.

2-way outlet gas tap complete


with well secured safety valve.
Special Bunsen burner gas outlet
complete with flame stabilizer
Allow builders work for the
installation of gas specified
TO COLLECTION

60

No.

3,000.00

60

No.

6,000.00

Lot

Sum 90,000.00

180,000.0
0
360,000.0
0
90,000.00
1,052,250

A.

SPLIT/FREE STANDING
AIRCONDITIONER
INSTALLATION
Supply and fix the following
Air-conditioning units
complete with all necessary
accessories and installed in
accordance with
manufacturers specification
and approved Engineers
shop drawings
!8,000 BTU/1.5HP LG/SHARP or
other equal and approved wall
mounted split air conditioning
unit complete with average of
14m length each of suction and
liquid refrigerant pipe with arm
flex insulation condensate
drainage fixing insulation and
accessories equipped with LCD
wireless remote control

B.

Ditto for 3HP free standing air


conditioning package unit

Allow for builders work for the


installation of air conditioning
package unit

16

Lot

No.

92,000.00

828,000.0
0

No.

270,000.0
0

4,320,000

Sum 250,000

250,000,0
0

TO COLLECTION
5,398,000

COLLECTIONS
1.

SANITARY FIXTURES

2,618,400

2.

WASTE/SANITARY PIPE

135,310

3.

RAIN WATER INSTALLATION

35,140

4.

COLD WATER INSTALLATION

414,755

5.

FIRE FIGHTING

1,020,540

6.

GAS INSTALLATION
AIR CONDITIONING
INSTALLATION

1,052,250

5,398,000

TOTAL TO GENERAL SUMMARY

10,674,395