C-line offers a unique Solution of Automatic Source Transfer System (ASTS) combining compactness
with high performance & customer convenience. The range covers ratings from 125 A to 2000 A in 5
frame sizes.
Changeover S-D consists of two separate sets of terminals for incoming supplies and a set of output
terminals to connect the common load. Thus, changeover switch maintains continuity of supply to
the load by alternating between priority & back-up supply.
POSITION I
POSITION O
POSITION II
Switch is in ON -I position with Switch is in OFF position and Switch is in ON -II position with
priority supply available at the outgoing terminals are isolated back up supply available at the
outgoing terminals
from both suppliers
outgoing terminals
1|Page
AST Controller
C-line
Motorised Changeover
2|Page
Supply monitor
Illuminated push buttons
Auto Mode
In auto mode source-I (priority source) is continuously monitored, in case of source-I failure AST
controller checks for the Source-II (back-up source ) . If it is available then AST controller gives
command to mortorised changeover to shift on source-II.
On restoration of source-I ( priority source ) motorised changeover moves back to it.
Illumintion in the push buttons will be functional Indication of the the motorised changeover switch
position.
Option of setting over voltage : Recommended setting 110% of the supply voltage
Option of setting under voltage : Recommended setting 90% of the supply voltage
Option of setting time delay : 0 -15 seconds
C-line
Motorised Changeover
Auto Mode
In auto mode source-I (priority source) is continuously monitored, in case of source-I exceeds the set
limits AuXC 1000L controller checks for the Source-II (back-up source ) . If it is available then
controller gives command to mortorised changeover to shift on source-II after the set delay time, it
also controls the startup and shutdown of the generator set, if any
When the Source-I (priority source) returns within the set limits, the unit switches over the load
again to priority source and controls the generator set cooling cycle.
Protection against UV, OV , phase loss, asymmetry , under frequency and over frequency.
6 programmable digital inputs & relay outputs (5NO + 1C/O)
Measuring and sensing of system variables
DG set start/stop control
Priority source swap
4|Page
5|Page
Parameters
Display Indicator
Display type
Source (I,II) Available
Indicator
Switch Position
Unique Control Function
Default Priority
Priority Source Swap
Source Sensing Setting
Voltage sensing
Under Voltage
Over Voltage
Frequency sensing
Phase Loss
Asymmetry
Other
RS-232
Additional 12-48V DC Power
Inputs
Generator Control Signal
Output
Alarm (open and close commands of the
Illuminated Push
Button Assembly
AST Controller
with wire
harness
AuxC-1000L
Controller with
wire harness
Yes
15 Status LED
display
Yes
Yes
Yes
Yes
Yes
-
Yes
Yes
Yes
Yes
Yes
-
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Flush Mounting
Flush + Base
Mounting
Yes
Flush Mounting
Auxiliary Contact
Installation
6|Page