exhaust air
supply air
In hot climates, the heat exchangers work just as well in reverse, i.e.
reclaiming cooling energy from the exhaust air to pre-cool, and dehumidify warm and humid incoming air. This reduces the overall cooling load
and results in better cooling performance at a lower cost. ECONOVENT
heat exchangers are easy to install and can be mounted either vertically
or horizontally if a more compact installation is required.
Flkt Woods
3667 GB 03.02
ECONOVENT
BROCHURE
ECONOVENT also produces wheels of sturdier aluminum foil and with wider foil spacing for use in particularly corrosive and polluted environments.
ECONOVENT wheels are made of flat and corrugated
aluminum foil of uniform width. This produces a
smooth and robust rotor surface which reduces the
leakage rate and edge corrosion.
Thousands of ECONOVENT heat exchangers have
been installed in hospitals, nursing homes, schools,
offices, stores, shopping centers, hotels and factories.
Superior ECONOVENT quality: In a comparison made
at a Norwegian University where cross-contamination
and carry-over tests were conducted, an ECONOVENT heat exchanger was compared to another unit
incorporating a wheel based on molecular-sieve technology. The ECONOVENT unit was a clear winner.
N2O-gas, toluene, cigarette smoke and outdoor dust
were used in the tests. In the ECONOVENT-unit, the
incidence of crosscontamination is 22%61% less than
in the unit equipped with a molecular-sieve wheel.
Flkt Woods
3667 GB 03.02
ECONOVENT
BROCHURE
Guide specification
A type PUM(AF) ECONOVENT Rotary
Heat Exchanger, manufactured by Flkt
Woods ECONOVENT
The Manufacturer shall be ISO 9001
certified.
CASING The casing shall be constructed as a singleskin, self-supporting, galvanized sheet steel structure
and include rotary wheel support beams and a purging
sector. The casing shall be supplied with access panels
to facilitate inspection and service. Size 215 and larger
shall be in two sections to facilitate shipping and handling. The smaller sizes can be delivered in a two-piece
special version.
Flkt Woods
3667 GB 03.02
ECONOVENT
BROCHURE
DRIVE The wheel shall be belt-driven along its perimeter. A constant-speed or variable-speed, fractional
hp drive motor shall be used. The motor shall be
mounted on a self-adjusting base to provide correct
belt tension. The variable-speed motor shall be specially manufactured for rotary heat exchangers and
provide constant torque throughout the speed range.
Moreover it shall include a slow-start feature and auto
2000
3000
4000 5000
10 000
20 000
30 000
50 000
100 000
150 000
Size
060
080
095
110
120
135
150
170
190
200
215
265
290
320
350
380
420
460
500
0.2
0.3
0.4 0.5
Air flow, m3/s
Flkt Woods
3667 GB 03.02
10
20
30
40
50
ECONOVENT
BROCHURE
Size 060240
D
E
A
H 2)
M
400
Inspection
window Inspection panel, optional
Inspektionsfnster
2) Height H is the dimension for a split
heat exchanger.
Size
060
080
095
110
120
135
150
170
190
200
215
240
960
1100
1200
1400
1500
1600
1700
1900
2100
2200
2400
2640
600
800
950
1100
1200
1350
1500
1700
1900
2000
2150
2400
60
60
60
104
104
104
104
104
104
104
104
104
990
1090
1190
1240
1340
1460
Size 265500
65
1)
DDdia.
A
H 2)
Size
265
290
320
350
380
420
460
500
2900
3100
3400
3660
4000
4500
4900
5400
430
430
430
430
430
430
470
470
2650
2900
3200
3460
3800
4200
4600
5000
120
120
120
120
120
120
185
185
1800
1900
2050
2180
2350
2600
2800
2050
Flkt Woods
3667 GB 03.02
Weight, kg
Standard Wider
Standard foil
foil
foil
spacing
spacing spacing
industrial version
95
130
145
165
210
215
265
305
360
415
430
530
90
125
140
160
195
200
245
275
335
355
395
480
200
240
270
290
350
395
500
550
600
740
Weight, kg
Standard Wider Standard foil spacing,
foil
foil
Industrial version
spacing spacing
composite rotor
870
970
1200
1300
1500
1800
2900
3500
770
870
1050
1120
1350
1600
2700
3200
970
1100
1350
1450
1700
2000
3500
3800
ECONOVENT
BROCHURE
Flkt Woods
3667 GB03.02
T 03619 30 00 F 03619 31 88
W www.flaktwoods.com