Preface

This document provides design considerations and guidelines for deploying enterprise network
solutions that include the Cisco Unified Computing System (Cisco UCS). This document builds
upon ideas and concepts presented in the Data Center, Storage Area Networking and
Virtualization Design Guides which is available online at
http://www.cisco.com/go/datacenter

Due to the length and size of this document, the information will be divided into smaller sections
and may comprise links to several other documents. The information in this document was
created from devices in a specific lab environment. All of the devices used in this document
started with a default configuration. If your network is live, make sure that you understand the
potential impact of any command.

Audience
This design and deployment guide is intended for the system architects, designers, engineers, and
Cisco channel partners who want to apply design practices for the Cisco Unified Computing
System and Virtualization.
This document assumes that you are already familiar with basic Data Center, Virtualization and
Storage Area Networking (SAN) terms and concepts and with the information presented in the
Data Center Design Guides. To review those terms and concepts, refer to the documentation at
the preceding URL.

Revision History
This document may be updated at any time without notice.

Revision Date

Comments

November 16th, 2009

Initial version of this document

April 23rd, 2010

Added SAN Storage Deployment Chapter

UCS Architecture Overview


Virtualization has created a market transition in which IT departments are trying to reduce costs
and increase flexibility. IT organizations are constantly working against existing rigid, inflexible
hardware platforms. Data center administrators have had to spend significant time on manual
procedures for basic tasks instead of focusing on more strategic, proactive initiatives. Unified
computing System unites Compute, Network, Storage access, and Virtualization into a single,
highly available, cohesive system. The Cisco Unified Computing System is designed and
optimized for various layers of virtualization (Server Virtualization, Network Virtualization etc.)
to provide an environment where applications run on one or more uniform pools of server
resources. The system integrates 10 Gigabit Ethernet unified network fabric with x86architecture servers.

UCS Architecture Building Blocks


From hardware and software architecture point of view, there are mainly six building blocks.
1. UCS Blade Server Chassis
2. UCS B-Series Blade Server
3. UCS Blade Server Adapters a.k.a Mezzanine Cards
4. UCS Fabric Interconnect Switch
5. UCS Fabric Extender
6. UCS Manager
There are five physical and then one software block called UCS Manager.

UCS Blade Server Chassis

The Cisco UCS 5108 Blade Server Chassis, is six rack units (6RU) high, can mount in an
industry-standard 19-inch rack. A chassis can accommodate up to eight half-width, or four fullwidth Cisco UCS B-Series Blade Servers form factors within the same chassis. The rear of the
chassis contains eight hot-swappable fans, four power connectors (one per power supply), and
two I/O bays for Cisco UCS 2104XP Fabric Extenders. A passive midplane provides up to 20
Gbps of I/O bandwidth per server slot and up to 40 Gbps of I/O bandwidth for two slots. The
chassis is capable of supporting future 40 Gigabit Ethernet standards. Furthermore, the midplane
provides 8 blades with 1.2 terabits (Tb) of available Ethernet throughput for future I/O
requirements.

UCS B-Series Blade Server


A blade server is a modual server optimized to minimize the use of physical space. It looks very
much like a line card that is inserted into a blade server chassis or enclouser. Typically a blade
server only provides compute resources (for instance processor, memory and IO cards etc.). The
UCS-B200-M1 Server is a half-width, two socket blade server consisting of 2xHD Slot and 12
DIMM Slots. Cisco UCS B-Series Blade Servers are based on Intel Xeon 5500 Series
processors.UCS B200-M1 series blade servers can support

Two Intel Xeon 550 series processors

Up to 96 GB of DDR3 memory

Up to two optional Small Form Factor (SFF) Serial Attached SCSI (SAS) hard drives in
73GB 15K RPM and 146GB 10K RPM versions

LSI Logic 1064e controller and integrated RAID

UCS Blade Server Adapters or Mezzanine Cards


Blade servers in the Cisco UCS Blade Server Chassis have access to the network fabric through
mezzanine adapters that provide up to 40 Gbps of throughput per blade server.There are different
adapters aka mezzanine cards options available for UCS B-Series blade server. It include either a
Cisco UCS VIC M81KR Virtual Interface Card, a converged network adapter (Emulex or
QLogic compatible), or a single 10GB Ethernet Adapter.

Refere to following URL for further details

http://www.cisco.com/en/US/prod/ps10265/ps10280/cna_models_comparison.html

Fabric Interconnect Switch


The fabric switch or the fabric interconnect switch, as we're going to call them, connects the
blade servers to the rest of the data center. The Cisco UCS 6100 Series Fabric Interconnect
Switch offers line-rate, low-latency, lossless 10 Gigabit Ethernet and Fibre Channel over
Ethernet (FCoE) functions.
The Cisco UCS 6100 Series Fabric Interconnect Switch provides the management and
communication backbone for the Cisco UCS B-Series Blades and UCS 5100 Series Blade Server
Chassis. They're built on the same ASICs as the Nexus 5000 Switch, although this is a different
box. And it is not interchangeable with the Nexus 5000 series. You cannot upgrade from a Nexus
5K to a UCS-6120XP fabric interconnect switch for example. Nor you can downgrade from
UCS-6120XP to Nexus 5K. They both are different systems and they have different internal
components.
NOTE:
Nexus 5000 series swithes are mainly use for data center applications. The discussion about
Nexus 5000 series switches is out of the scope of this document. Please refer to the following
URL for more information about it.

http://www.cisco.com/en/US/products/ps9670/index.html

The Cisco 6100 Series hosts and runs the Cisco UCS Manager in a highly available
configuration, enabling the fabric interconnects to fully manage all Cisco Unified Computing
System elements.

Fabric Extender
Fabric Extender is a line card that inserts into one of the blade chassis enclosure slot. The actual
wiring between UCS chassis and UCS Fabric Interconnect Swith ports runs through the Faric
Extender module. The Cisco UCS 2100 Series Fabric Extenders bring the unified fabric into the
blade server enclosure, providing 10 Gigabit Ethernet connections between blade servers and the
fabric interconnect, simplifying diagnostics, cabling, and management. It has four 10 Gigabit
Ethernet, FCoE-capable, Small Form-Factor Pluggable Plus (SFP+) ports that connect the blade
chassis to the fabric interconnect. Each Cisco UCS 2104XP has eight 10 Gigabit Ethernet ports
connected through the midplane to each half-width slot in the chassis. Typically configured in
pairs for redundancy, two fabric extenders provide up to 80 Gbps of I/O to the chassis.

UCS Manager
Cisco UCS Manager acts as the central nervous system of the Cisco Unified Computing System.
It integrates the system components from end to end so the system can be managed as a single
logical entity. Cisco UCS Manager provides an intuitive GUI, a command-line interface (CLI),
and a robust API so that it can be used alone or integrated with other third-party tools.
Everything about server configuration-system identity, firmware revisions, network interface
card (NIC) settings, HBA settings, and network profiles-can be managed from a single console,
eliminating the need for separate element managers for every system component. Cisco UCS
Manager is embedded in the fabric interconnects switches.

Utility Computing with Stateless Server

UCS provides the infrastructure to support stateless server environments. Utility Computing, in
general allows for logical servers (OS/Applications) to be run on any physical server or blade, in
a way that hides traditional H/W identifiers (WWN, MAC, UUID etc.) as an integral part of the
logical server identity. This logical server identity is called "UCS Service Profile"

The Unified Fabric


The unified fabric is based on 10 Gigabit Ethernet. The unified fabric supports Ethernet as well
as Fibre Channel over Ethernet (FCoE). Virtualized environments need I/O configurations that
support the movement of virtual machines (VMs) across physical servers (also called compute)
while maintaining individual VM bandwidth and security requirements. The Cisco Unified
Computing System delivers on this need with 10-Gbps unified network fabric.

Types of UCS Fabric Interconnect Ports


Cisco UCS Fabric Interconnects provide these port types:

Server Ports
Server Ports handle data traffic between the Fabric Interconnect and the adapter cards on the
servers.
You can only configure Server Ports on the fixed port module. Expansion modules do not
support Server Ports.

Uplink Ethernet Ports


Uplink Ethernet Ports connect to external LAN Switches. Network bound Ethernet traffic is
pinned to one of these ports.
You can configure Uplink Ethernet Ports on either the fixed module or an expansion module.
Uplink Ports are also known as border links or Northbound ports

Uplink Fibre Channel Ports


Uplink Fibre Channel Ports connect to external SAN Switches.
They can also directly connect to the SAN Storage Server itself using FC protocols (typically for
LAB based environment).
Network bound Fibre Channel traffic is pinned to one of these ports.
You can only configure Uplink Fibre Channel Ports on an expansion module. The fixed module
does not include Uplink Fibre Channel Ports.

Fabric Interconnect (6120XP) Ethernet


Switching Modes
The Ethernet switching mode determines how the Fabric Interconnect behaves as a switching
device between the servers and the network. The UCS fabric interconnect operates in either of
the following Ethernet switching modes:

End-Host Mode

Switch Mode

End-host Mode

End-host mode allows the Fabric Interconnect to act as an end host to the network, representing
all server (hosts) connected to it through vNICs. This is achieved by pinning (either dynamically
pinned or hard pinned) vNICs to uplink ports, which provides redundancy toward the network,
and makes the uplink ports appear as server ports to the rest of the fabric. When in end-host
mode, the Fabric Interconnect does not run the Spanning Tree Protocol (STP) and avoids loops
by denying uplink ports from forwarding traffic to each other, and by denying egress server
traffic on more than one uplink port at a time.

For the purpose of this document and for running other applications using VMware on UCS, it is
recommended to configure the fabric interconnect in the End-Host mode. The setting can be
easily located on the General Fabric Extender screen.

Switch Mode
Switch mode is the traditional Ethernet switching mode. In this mode the Fabric Interconnect
runs STP to avoid loops, and broadcast and multicast packets are handled in the traditional way.

Switch mode is not the default Ethernet switching mode in UCS, and should be used only if the
Fabric Interconnect is directly connected to a router, or if either of the following are used
upstream:

Layer 3 aggregation

vLAN in a box

Click here for more information on the Ethernet Switching mode with UCS

Setting up UCS Manager


Following table explains various hardware components involved in deploying a UCS based
setup. There are more pieces in a network than what is shown in the following table. Following
table mentions only the important pieces in the UCS design.

Hardware Component
Name

Description

UCS-6120XP

20 Fixed ports, 10GE/FCoE, 1 expansion module

UCS-2104XP

4 Port Fabric Extender

UCS-B200-M1

Half width blade server

Catalyst 6506

Switch for uplink ethernet connectivity

LC to SC cable

Standard fiber cable to connect 6120XP to Cat6K Switch

SFP-10G-SR

Transceiver in 6120XP for ethernet uplink

X2-10GB-SR

Transceiver in CAT6K for ethernet connectivity with UCS6120XP

SFP-H10GB-CU5M

Twinax cale to connect Fabric Extender to UCS-6120XP

The following steps are based on a UCS Manager GUI based setup process although a CLI setup
process is also available that is not discussed as part of this document. Open a standard web
browser and browse the management ip address of UCS-6120XP switch.
Only for the first time, you will see the express setup option

Continue with the express setup as follows

Since this configuration was done using single UCS chassis with single UCS-6120XP fabric
interconnect switch, hence the Standalone mode is selected as shown in the following picture

In typical deployment it is recommended to have redundancy by having two UCS chassis


with two UCS-6120XP switch for high availability

The high availability mode is called "Clustering"

In clustering or redundant deployment mode, the secondary chassis setup would sync up
with the primary chassis using a "Cluster Key ID" and the initial setup process of the
secondary chassis would be streamlined based on the information downloaded from the
first chassis.

After hitting submit, the fabric interconnect will reboot and after a while when you login, the
"Express Setup" option is gone and you will see a following screen.

When you click Launch button, it will ask you to run the following java program.

NOTE: It is highly recommended to use latest JAVA JRE (Version 6 Update 17 was available at
the time of writing of this document). Testing has shown that the previous versions might either
crash, won't work, or hangs the session to the UCS Manager.

You could save this file on your desktop or any other folder because next time you can
only run this program to load the UCS Manager

Once the installation is done, you will be presented with the following login screen again.

And now you will see the following screen with only one Fabric Interconnect shown and no
chassis so far.

Till this point the basic setup is completed

From here onward it is your role to connect the chassis to the Fabric Interconnect in this
"non-redundant" setup.

Initial Configuration and Policies


At this point it is good idea to validate few items before moving forward. If you are intended to
use two black color twinax cables between UCS-6120XP and UCS Chassis then you should
define it under the Equipment policy setting as shown below. Also notice that only 1, 2 or 4 links
are possible between UCS-6120XP and UCS chassis fabric interconnect. The idea of these links
is to distribute the blade server traffic load between 10GE twinax cables. In our scenario we have

only two half width blades on our single chassis system. So blade#1 will be using link#1 and
blade#2 will be using link#2. This assignment is automatic and cannot be changed.

Also check the following configuration to make sure that as admin you can see all the tasks
because by default only "Faults and Events" are selected in the filter.

The recommended and default ethernet mode of operation for UCS-6120XP is "End-HostMode". When you change the Ethernet switching mode, the UCS Manager logs you out and
restart the fabric interconnect (UCS-6120XP). For cluster configuration, the UCS Manager
restarts booth fabric interconnect sequentially. Launch the "LAN Uplink Manager" to verify and
configure the mode.

In the following picture, the mode is "Switch" right now. Change it to End-Host mode.

Also create a vlan that will be used to connect for the VMware ESX server management and for
other management purposes. This should be a vlan that would not carry other traffic.

For VLAN ID configuration, its worth noting that Cisco does not recommend using VLAN 1 as
most Enterprises either remove VLAN 1 or disable it. In addition, when configuring VLAN, it is
worth considering configuring all the VLANs which the servers will need to be part of at this
point instead of later down the line. If its later down the line, an updating template is necessary to
propagate this information to the blade servers which may cause the server to reboot.

In the following diagram VLAN-id 100 is used as VMware ESX management VLAN.

On the CAT6K side configure following

interface TenGigabitEthernet5/2
description UCS-6120-XP Fabric Interconnect Port 20
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
spanning-tree portfast edge

When we will reach to the point where we would configure the vNIC, in order to make it work or
accessible, one will have to make sure to select Native VLAN option as follows. This could be
different if you had native vlan configured on the CAT6K trunk port. If you had native vlan

keyword configured on the CAT6K then you should not check on the native vlan option on the
UCS Manager.

Configure Ports on the UCS Manager


There are three different types of ports that can be configured on the UCS-6120 switch

Uplink Ethernet Port

This is used to connect UCS-6120 to the uplink device which is typically a Nexus 5K Access
Layer Switch. But other options like Cisco Catalyst 6500, Cisco 4900M or C4948 10GB
Switches are also supported. In this setup UCS-6120 is connected to CAT6K's 10GE port (using
X2-10GB-SR transceiver in CAT6K with SC-LC fiber cable) for uplink ethernet connectivity.

Server Port

Server ports connect UCS-6120 to the UCS fabric extender that is physically plugged into the
UCS chassis (UCS fabric interconnect switch connects to the blade servers via UCS fabric
extender)

Uplink Fiber Channel Port

Fiber Channel Port doesn't come by default with the UCS-6120 switch. It has to be ordered as an
expansion slot line item during UCS order and it plugs into the UCS-6120 expansion slot on the
very right hand side. This port provides connectivity to the SAN Storage Array. In this setup
Cisco Video Surveillance 4-RU Storage System with 42 x 1000-GB drives ( Part number CIVSSS-4U-42000) is used as a SAN storage device (OMEed from NexSan SataBeast Storage Array).

http://www.cisco.com/en/US/prod/collateral/vpndevc/ps6918/ps9145/ps9152/product_bulletin_c
25-457325_ps9153_Products_Bulletin.html

It supports FC as well as iSCSI protocol. In a live deployments the SAN storage is carefully
selected and it is not the scope of this document to discuss the SAN storage array selection
criteria. For the purpose of this document, the focus is on the initial setup of UCS. Please refer to
one of the Data Center SRND/CVD documents for the SAN storage discussion

http://www.cisco.com/go/datacenter

Connecting UCS-6120XP Switch to UCS5108 Chassis


Now it is time to configure the Unified Fabric Interconnect Switch (UCS-6120) Port to be
connected to the Chassis.

Assuming that the twinax cable is already connected between the chassis and the UCS-6120,
configure the port as follows by selecting Configure as Server port.

Since we have two twinax cables on UCS-6120 connected to the two ports in the same fabric
interconnect, we have selected second port as well
Note that like may other tasks, the same task can be archived using different GUI options so your
steps may vary but the objective is same to set port as Server Port

And now when you look at it in the Main Topology View window, you can see two links
connected

Following picture shows how the internal backplane port are connected to fabric extender and
then fabric extender connects to the fabric interconnect switch.

Connecting UCS-6120XP Switch to Uplink


Ethernet Switch

Each UCS Fabric Interconnect provides ports that can be configured as either Server Ports or
Uplink Ports. Ports are not reserved for specific use, but they must be configured using the UCS
manager (preferably). You can add expansion modules to increase the number of Uplink Ports on
the Fabric Interconnect. LAN Pin Groups are created to pin traffic from servers to a specific
uplink Port.

UCS-6120XP ports are 10GE ports and hence the regular SFP transceiver cannot be used to
connect it to the uplink ethernet port. Unlike 10/100/1000 bits ethernet port, 10GE ethernet port
cannot do auto-negotiation of speed and duplex and hence the UCS-6120XP port should be
connected to the 10GE uplink ethernet port. A 10GE transceiver (e.g SFP-10G-SR) is required on
the UCS-6120XP switch. Make sure to order it as part of your UCS order because the Netformix
ordering tool will not give you any indication if you had missed it.

On the CAT6K switch, X2-10GB-SR SC interface type transceiver can be used and a regular LCSC fiber cable can be used.

Or you could have CVR-X2-SFP10G adapter inside tha X2-10GB-SR to convert it into a LC
type connection and can use regular fiber cable or twinax (SFP-H10GB-CU5M) cable to connect
UCS-6120XP to uplink Ethernet Switch.

The port configuration on UCS-6120XP are done at the Service-Profile vNIC level. VLAN
trunking could be seleted either YES or NO. In a typicaly deployment this setting should be set
to YES. And on the CAT6K switch side the port should be configured as a trunk port. Following
is an example of CAT6K configuration

interface TenGigabitEthernet5/2
description UCS-6120-XP Fabric Interconnect Port 20
switchport
switchport trunk encapsulation dot1q

switchport mode trunk


spanning-tree portfast edge

show interfaces tenGigabitEthernet 5/2


TenGigabitEthernet5/2 is up, line protocol is up (connected)
Hardware is C6k 10000Mb 802.3, address is 0023.04d7.1d5d (bia 0023.04d7.1d5d)
Description: UCS-6120-XP Fabric Interconnect Port 20
MTU 1500 bytes, BW 10000000 Kbit, DLY 10 usec,

reliability 255/255, txload 1/255, rxload 1/255

On the UCS-6120XP side the steps are very similar to configuring the server port. In the UCS
Manager GUI, right click on the port that you want to configure as a uplink ethernet port and just
select the option.

Once the connection with the ethernet switch is established the port will be moved under the
Uplink Ethernet port group and will show enabled/up state as follows.

Service Profile Creation


Service Profiles are what define a blade server as a "complete server". Service Profiles contains
all the information related to a server.
For example the NIC card that it has and the MAC address that is going to be assigned to the
NIC etc. Service Profile is the definition of actual physical hardware.

In the UCS Manager in the"Server" tab, you will notice that root organization is already created
with different default options. Right now the information that is available is enough for us to
create a service profile and apply it to the blade server.

There are many different possible ways of doing these steps and this document only discusses
one possible way. In a Multi-Tenant environment or for large organizations where there is a need
to separate resources based on various functional groups for example Engineering, Support,
Sales etc. You can define sub-organization under "root" organization too. However, this
document does not discuss above or other advanced options.

Under the server tab select "Create Service Profile (expert)" option. This is very important that
you select this option otherwise you will end up getting error messages to fix other steps. That
are not very difficult to fix but this approach is the fast and easy approach to create a service
profile and apply it to the physical blade

Specify the unique identifier for the service profile. This name can be between 1 and 16
alphanumeric characters. You cannot use spaces or any special characters, and you cannot change
this name after the object has been saved.

The UUID drop-down list enables you to specify how you want the UUID to be set. There are
multiple options available.

You can use the UUID assigned to the server by the manufacturer by choosing Hardware
Default. If you choose this option, the UUID remains unassigned until the service profile is
associated with a server. At that point, the UUID is set to the UUID value assigned to the server
by the manufacturer. If the service profile is later moved to a different server, the UUID is
changed to match the new server. So in order to keep the machine stateless, we have picked up
option to specify a UUID manually. Typically a customer would create a UUID pool and then it
should be picked up from the pool automatically. Also it is important to make sure the UUID is
available by clicking the corresponding link.

Storage
Next step is to configure the storage options. If you want to use the default local disk policy,
leave this field set to Select Local Storage Policy to use. If you want to create a local disk policy
that can only be accessed by this service profile, then choose Create a Specific Storage Policy
and choose a mode from the Mode drop-down list.

We have selected Create Local Disk Configuration Policy link. It enables you to create a local
disk configuration policy that all service profiles can access. After you create the policy, you can
then choose it in the Local Storage drop-down list.

Select simple in the following screen.

Simple

You can create a maximum of two vHBAs for this service profile

Expert

You can create an unlimited number of vHBAs for this service profile

No vHBAs

You cannot create any vHBAs for this service profile

If you want to:

Use the default WWNN pool, leave this field set to Select (pool default used by default).
Use a WWNN derived from the first vHBA associated with this profile, choose "Derived from
vHBA".
A specific WWNN, choose 20:XX:XX:XX:XX:XX:XX:XX or
5X:XX:XX:XX:XX:XX:XX:XXand enter the WWNN in the World Wide Node Name field.
A WWNN from a pool, select the pool name from the list. Each pool name is followed by
number of available/total WWNNs in the pool.

We randomly picked up following WWNN name. Because we didn't want to assign the WWNN
name from the physical HBA to make our server stateless. Make sure to verify that it is available.

Ignore the warning in the following screen

Configure the networking portion of the service profile creation

This is important to note that a service profile that has two vNICs assigned
would require a blade in a chassis with two IOMs connected to two fabric
interconnects, and that service profile would fail to associate to a blade in
a chassis with only a single IOM.

Similarly, a service profile that defines both vNICs and vHBAs (assuming the
presence of the Menlo or Palo adapters) would fail to associate to a blade
with an Oplin adapter because the Oplin adapter doesnt provide vHBA
functionality.

The bottom line is that the administrator needs to ensure that the service
profile is properly configured for the hardware by making sure that the
policies and profiles are properly configured.

For now we have selected virtual CD as the first boot device and local hard drive as second. It is
also a good practice to have it this way in case your local hard drive has some issues so that you
can always boot from the CD.

Now the fundamental portion of service profile are configured and the profile will be assigned to
one blade server. It is again worth mentioning that in a trypical deployment you would want to
use Service Profile Templates rather than creating Srvice Profile profiles for each and every
single blade in your system

The following list shows the available servers in the system

IPMI Profile
Intelligent Platform Management Interface (IPMI) technology defines how administrators
monitor system hardware and sensors, control system components and retrieve logs all by using
remote management and recovery over IP. IPMI runs on the BMC (Baseboard Management
Controller) of the blade server and thus operates independently of the operating system (or the
hypervisor in case of virtualization). Since IPMI operates independent of the operating system, it
provides administrators with the ability to monitor, manage, diagnose and recover systems, even
if the operating system has hung or the server is powered down.
In order to provide direct access to the BMC to make IPMI services available, IPMI profiles are
created and assigned to the blades. An IPMI profile contains a username, password and a role for
that username.

Profile name is defined in the following screen

Notice that in the following screen you will notice a configuration error saying "mac-addressassignment"

On the blade server properties page you can click on "Change MAC Address" option to change
its MAC.

You may assign the MAC from the MAC pool or you may elect to assgin it manually. Here is is
assigned manually.

After completing all these stpes, the blade server is configured and is ready to be used. In the
next section of this deployment guide we will discuss how to install VMware ESX Server
(Hypervisor) to be installed on the UCS blade server.

Introduction

Although not required but readers are highly encouraged to get familar with the concepts
discussed in the following document first
Deploying UCS Blade Server with UCS Manager for Virtualization
Once the blade server is provisioned using the UCS manager and necessary configurations like
service profile creation etc. is done. The next step is to configure and deploy blade server for
various applications. Since the blade server is very attractive for virtualization based
applications, in this document the VMWare ESXi installation is discussed. The concepts
discussed here are also applicable to non-vmware based hypervisor and any other vendor's
software application installation as well.

During this setup no physical keyboard, mouse or monitor was attached to the physical KVM
port on the blade server. It should be noted that this document only discusses the installation
using the UCS manager built-in software KVM switch. Although there could be various other
ways to install the software on the blade server (for instance USB DVD based installation on the
blade server).
Terminologies
BMC - Baseboad Management Controller

Baseboard Management Controller (BMC), also called as Service processor, resides on each
blade for OS independent/pre-OS management. The BMC's focus is to monitor/manage a single
blade in the UCS chassis. BMC should be assigned an IP address so that the UCS Manager's
software KVM can connect to it using the IP. The UCS manager talks to the BMC and configures
the blade. BMC controls things like BIOS (upgrade/downgrade), assigning MAC addresses,
assigning WWNs, etc.

Using KVM Connection to Setup the Blade Server

Each physical blade is capable of supporing remote KVM and remote media access. This is made
possible by associating IP addresses for the cut-through interfaces that correspond to each blade's

BMC. Typically, these addresses are configured on the same subnet as the management IP
address of the UCSM. This pool is created from the Admin tab, by selecting "Management IP
Pool".

In our example, the ip address 10.194.40.208 is used to connect to the UCS Manager. And
10.194.40.33 is assigned to the " BMC Management IP Pool" so that UCSM can connect to blade
server using KVM and will also be used for remtoe media access.

Notice that in our example we have only one IP address because we are configuring only one
blade right now. So one ip address is required per blade server.

In the following screen it is shown that chassis-1/blade-1 is assigned the 10.194.40.33 IP address
for remote KVM and virtual media access.

Following screen shows the IP address block that is allocated for BMC.

Now connect to blade server's software based KVM Console

This should open a new dialog box that will show the console screen of the blade server.

Now you can launch the virtual media from within the UCS Manager windows and can map
vmvisor (ESXi4.0) iso image as virtual CD/DVD.

The macros are available to perform basic tasks as follows

You may also setup the boot oder on the blade server's BIOS

Now the blade should dedect the virtual CD/DVD and will start booting from it.

ESXi 4.0 installation will continue

The installation is done. Now the next step should be to assing a management ip address to the
ESXi server itself so that you can access it individually or can add it to your vCenter Setup.

At this point, the VMWare EXSi 4.0 hypervisor (VMware-VMvisor-Installer-4i.0.0164009.x86_64.iso) is installed on the UCS blade server and you can customize the vmware
hypervisor with the IP address related information so you can connect to it using the vCenter and
manage it from the vmwar vCenter clinet. Also right now no DataStore is created. So once you
login to ESXi server, you can create data store either using iSCSI or SAN based data store or
NAS.

So after that part is done, if your VLAN and network connectivity is in place, you should be able
to connect/ping the 172.19.246.187.

Notice that there are two different ethernet networks here.

UCS Management Network:

10.194.x.x network (is used here in this setup to connect to UCS Manager and for KVM over IP
purposes for the blade.This is out of band network and connect to the management port on the
UCS fabric interconnect UCS-6120XP). The UCS Manager is the management application that is
embedded inside the UCS-6120XP fabric interconnect switch.

VMWare Management Network:

172.19.246.x network (this is used to connect the vmware hypervisor using the in-band network
so that it can be managed by the vCenter. This same network can be used for iSCSI traffic if
needed but it is not recommended). So in our setup, the ESXi4 is running on the local hard drive
on the blade server (ESXi 4 can also boot from the SAN itself but it is not covered in this
document). Logically the vmware management traffic will be going through the UCS Chassis
fabric extender to UCS fabric interconnect 6120XP switch. The 6120XP is connected to CAT6K
10GE port in this setup. Although the ethernet uplink could be Nexus 5K or Nexus 7K switch as
well.

Introduction
This document describes the procedure and concepts that can be used to configure the UCS for
the networking on your LAN network. There could be many different VLAN configured in a
LAN environment for different applications and purposes. For example one VLAN VMware
ESXi server management and access purposes and another for the server application that is
running on the VMware ESXi server as a virtual machine.

In UCS the implementation of VLAN is influenced by the concepts of End-host mode. The UCS
system by default works in End-host mode. In End-host mode the UCS 6100 series fabric
interconnect appears to the external LAN as an end station with many adapters.

Make sure you have read and undersood the following document. It will provide the foundation
for the concepts discussed here
Deploying UCS Blade Server with UCS Manager for Virtualization

Network Adapters
The IP networking between the virtual machine is done via the different type of adapters that are
part of the blade server. There are four types of network adapters that are supported to provide
functionality required for the diverse workload in a Data Center.

1. UCS 82598KR-CI 10 Gigabit Ethernet Adapter


2. UCS M81KR Virtual Interface Card
3. UCS M71KR-E Emulex Converged Network Adapter
4. UCS M71KR-Q QLogic Converged Network Adapter

Follow the links above to take a look at the detailed description of each one of them.

UCS 82598KR is 10 Gigabit Ethernet card which provides dual port Ethernet connectivity and
designed for efficient high performance Ethernet transport. The important thing to notice here is
that this card doesn't provide Fiber Channel port.

UCS M71KR-E provides a dual port connection to the midplane to the blade server chassis. This
card has 10 Gigabits per second Ethernet and 4 Gigabits per second fiber channel controller for
fiber channel traffic all on the same mezzanine card. The UCS M71KR-E presents two discrete
fiber channel HBA ports and two 10 Gbps Ethernet network ports to the operating system.

UCS M71KR-Q provides a dual port connection to the midplane to the blade server chassis. This
card has 10 Gigabits per second Ethernet and 4 Gigabits per second fiber channel controller for

fiber channel traffic all on the same mezzanine card. The UCS M71KR-R presents two discrete
fiber channel HBA ports and two 10 Gbps Ethernet network ports to the operating system.
The only difference between M71KR-E and M71KR-Q is that former has a Emulex fiber channel
controller and later has Q-Logic FC controller.

UCS M81KR card is a dual port 10 Gbps Ethernet mezzanine card that supports upto 128 PCIe
virtual interfaces that can be dynamically configured.

This document and the concepts presented here are based on the UCS M71KR
Converged Network Adapter

VLAN implementation
In Unified Computing system (UCS) each VLAN is identified by a unique ID. The VLAN ID is
a number that represents that particular VLAN. VLAN can be created in such a way that it is
visible in either one fabric interconnect or both fabric interconnect. It is also possible to create
separate VLANs with same name on both of the fabric interconnects but with different VLAN
IDs. While creating a VLAN in UCS, the VLAN is also assigned a name but the name of a
VLAN is known only within the UCS environment, and outside of the UCS the VLAN is
represented by the unique ID.

Guidelines and Requirements


The configuration and options presented in this document assumes that following guidelines are
met and understood.

UCS-6120XP Fabric Interconnect Switch should be in the End Host mode. Switch mode
is not discussed as part of this document

This document only presents the UCS Manager GUI based configuration option.

There could be multiple ways to configure the UCS Manager GUI to achive the same
tasks

In End Host mode, all the blade servers and their interfaces attached with the 6120XP
looks like bunch of NIC cards to the 6120XP

There is an inherit pinning happening between the blade server and uplink Ethernet
switch (CAT6K or Nexus5K)

VLAN creation in UCS means that the configured VLANs are automatically allowed as
well

vNIC within the UCS system is a host-presented PCI device which is managed centrally
by the UCS manager.

Uplink Switch Configuration


Make sure that the appropriate VLANs are created on the uplink switch (e.g CAT6500).
Following snipper shows a CAT6500 configuration

interface TenGigabitEthernet5/2
description Connected To: UCS-6120-XP Fabric Interconnect Port 20
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
spanning-tree portfast edge

show vlan

VLAN Name

Status

---- -------------------------------- --------433

CVP_TestBed_VLAN

100

Management VLAN

active
active

UCS Fabric Interconnect Configuration using UCS Manager


It is highly recommended to create all the necessary VLANs before configuring the Service
Profile.

o Create a Common/Global VLAN under the LAN Tab in the UCS Manager as
shown in the following picture
o A common/global VLAN as the name suggest visible to both fabric interconnect
switches

This VLAN (For example VLAN 433) must be visible under the Servers tab. Also make
sure right VLAN-ID is populated

Further verification can be done by looking under the equipment tab in UCS Manager by
making sure that the VLAN are visible under the appropriate vNIC as shown in the
following picture

With the above configuration the virtual machine should be able to ping the default
gateway and the IP connectivity should be completed.

Creating VLANs After Creating Service Profile


As mentioned before that it is recommended to create all the VLANs before creating a service
profile. But UCS is flexible to accomodate and apply the new VLAN to the existing Service
Profiles as well. So in this situation, few considerations should be made.

If you configure a VLAN after the Service Profile creation and if you notice that the "new"
VLAN is not bind to the vNIC on the blade server then the solution is to modify the vNIC
configuration and add the new VLAN to it.

Under the Servers tab in UCS Manager check to see if the "new" VLAN is visible or not.
Following picture shows that the "new" VLAN 433 is not visible.

Click "Modify" on the vNIC configuration option (shown in the above picture)

Following screen shows the Modify vNIC screen

Make sure the VLAN trunking options is checked and Native VLANs is correctly
selected as per your IP network policy. And then check the "new" VLAN (VLAN 433 in
this case)

This should add the new VLAN to the vNIC