Gas Turbine

General User Information

P+I Diagram Symbols, Explanations

Angle valve

Representation of Media
Oil(e.g. fuel oil, lube oil, control oil)
Air

Straightaway pressure reducing


valve

Combustible gases
(e.g. natural gas, blast furnace
gas, coke oven gas)

Straightaway cock

Noncombustible gases
(e.g. exhaust, inerting gas, flue
gas, oxygen, nitrogen)

Angle cock
Three-way cock

Transmittal, reproduction, dissemination and/or editing of


this document as well as utilization of its contents and
communication there of to others without express
authorization are prohibited. Offenders will be held liable for
payment of damages. All rights created by patent grant or
registration of a utility model or design patent are reserved.

Piping and other Lines


Piping, flow line,
general

Four-way cock

Pressure sensing, control or signal


line

Butterfly valve

Pipe,
electrically heated

Multiblade damper

Flexible line
(e.g. hose)

Flow restrictor with orifice plate


(e.g. orifice)

Crossing pipes and flow lines


(crossing without connection)

Types of Actuation
Hand-actuated shutoff valve

Cross junction of flow lines


(intersection with connection
fittings)

Electric motor-actuated shutoff


valve

Spray atomizer for fluids, spray


nozzle

Solenoid-actuated shutoff valve

Discharge to atmosphere for


gas/steam

Fluid-actuated shutoff valve (e.g.


hydraulic or pneumatic)
Piston-actuated shutoff valve (e.g.
hydraulic or pneumatic)

Discharge to atmosphere above


roof or through outside wall

Diaphragm-actuated shutoff valve


Shutoff valve actuated by pressure
of the working fluid acting against
a fixed pre-set spring force

Shutoff Valves
Shutoff valve,
general
General Symbols

Valve with progressive adjustment


characteristic

Mixing section

Three-way valve
Silencer

Class: Restricted

Shutoff valve with safety function


Check valve,
general

Steam trap

Shut off valve,


straightaway valve

Surface heat exchanger, general


(without crossing media flows)

Straightaway valve with


progressive adjustment
characteristic

Combustion chamber

Siemens AG
Energy Sector

3.0-0070-0001/1
MB

0700EN

Gas Turbine
General User Information

P+I Diagram Symbols, Explanations

Firing, burner
general

Symbol with KKS for equipments

Pool
general

Symbol with KKS for measuring


instruments

Tank
general
Symbols for Hydraulic and Pneumatic Systems

Vessel with dished ends


general

Hydraulic pump with one direction


of flow

Gas cylinder

Hydraulic pump with electric motor


Scale
general
Hydraulic motor with one direction
of flow

Prime mover with expansion of the


working fluid (e.g. turbine)

Filter, strainer
Transmittal, reproduction, dissemination and/or editing of
this document as well as utilization of its contents and
communication there of to others without express
authorization are prohibited. Offenders will be held liable for
payment of damages. All rights created by patent grant or
registration of a utility model or design patent are reserved.

Electric motor
general

Spring-loaded check valve

Alternating current motor


general

Check valve without spring

Direct current motor


general

Non-loaded check valve


Throttle valve

Rotating current generator


general (e.g. generator)

Viscosity-dependent throttling

Hydraulic pump
general

Pressure limiting valve

Compressor, vacuum pump


general

Follower valve

Reciprocating compressor,
Reciprocating vacuum pump
Pressure control valve without vent

Liquid jet pump,


Propellant vacuum pump
Separator
general

Single-coil 3/2-way valve


2/2-way directional control valve

Pressure measurement, gauge


Cooler without indication of line for
cooling fluid

5/2-way directional control valve

Filter, general

Throttling directional control valve

Switch

Valve
Servo valve

Temperature transducer
Cylinder with reciprocating piston

Class: Restricted

Position transducer

Siemens AG
Energy Sector

3.0-0070-0001/2
MB

0700EN

Gas Turbine
General User Information

P+I Diagram Symbols, Explanations

Simple-action cylinder (spring


piston return)

or

Solenoid coil
Spring

or

P+I Diagram Limits


Customer-defined connection or
connection to another P+I diagram
in the Operating Manual (... =
terminal flange no.)
Connection to another sheet of this
drawing
X = Connection number
Y = Number of the sheet on which
mating flange of connection X is
depictedD1
=
Diagram
quadrant of mating flange X
depicted on sheet Y
XY

The omission symbol is located


between the first (e.g. burner
MBN12AV001) and last identical
item in the system (e.g. burner
MBN12AV012). KKS identifiers for
items within such series are
assigned in ascending order (e.g.
the KKS of the 4th burner is
MBN12AV004).

Connection to another P+I


diagram (cf. respective legend)

Class: Restricted

Transmittal, reproduction, dissemination and/or editing of


this document as well as utilization of its contents and
communication there of to others without express
authorization are prohibited. Offenders will be held liable for
payment of damages. All rights created by patent grant or
registration of a utility model or design patent are reserved.

X BLY (D1)

or

Omission symbols for system


items (e.g. burners) which are
present as multiple identical items
that differ only in their KKS
identifiers (used for the sake of
clarity).

Siemens AG
Energy Sector

3.0-0070-0001/3