You are on page 1of 5

APT 300

GROUT GC XI MNG CHO NG GEN CP D


NG LC KHNG TCH NC KHNG CHA CT
M T
APT 300 l grout (va lng) gc xi mng
khng co ngt, khng cha clorua v
khng tch nc ngay c khi chy
cao.
Thch hp cho bm va ng gen c
phng ng hay nm ngang cho kt
cu d ng lc.
APT 300 c ph gia chng co ngt v
ph gia siu do gip ngn cn co ngt
c trng thi do v cng.
TNH NNG K THUT
- Bt mu xm/xi mng;
- chy (cn chy ASTM C939): 15 - 30
giy
- Cng nn:
o 21 MPa 7 ngy tui
o 35 MPa 28 ngy tui
- Thi gian ng kt (ASTM C953): 6-12
gi
- Thay i th tch (ASTM C1090):
o 0.0%-0.1% 24 gi
o 0.2% 28 ngy.
- Tch nc (ASTM C940): 0% sau 4 gi;
- Dung trng t (ASTM C138): 1900-2000
Kg/m3;
- thm (ASTM C1202): <2500 couloms
sau 6 gi.
- Hm lng clorua : <0.005% theo dung
trng xi mng s dng.
- Florua, sun-phua, nitrat: Khng c.
- Khng c ct gip tng kh nng lp y
l rng, hng trong lng kt cu s
dng.
NG DNG
- Dng cho ng gen, l h, u vo, l rt
cho kt cu d ng lc.
- S dng cho khng gian cht hp ti
grout c ct kh chy lp y.
- ng gen, l m, l rt, ca rt cn phi
c lm sch khi bi bn, tp vt, du
m, du ha v bt k cht gy hi no
trong khi thi cng.
- 35-42.5 nc theo trng lng hn
hp vo thng trn hoc thng cha.
Lng nc chnh xc cn phi c xc
nh trc khi s dng.
- grout vo lng nc sn. Kin
ngh s dng my trn tc cao 1800
vng/pht (rpm) hoc cao hn c cnh
trn ct cnh (gim lc ct vt liu).
- Trn trong khong 3 pht tnh t lc t
sau cng hoc cho ti khi hn hp t
c ng nht.

Tip tc khuy cho ti khi t c


chy ti u.
Lu : i) Lng nc trn c th ph
thuc vo tc trn, tc trn cao th
lng nc trn thp i; ii) Khng kin
ngh trn tay hoc s dng my trn tc
thp. Tuy nhin khi s dng my/ que
trn tc thp, lng nc trn th
vo khong 45% theo khi lng vi thi
gian trn lu hn (khong 5 pht hoc
ti khi t ng u).
- Bm phi cho m bo rng grout chn
lp y ng gen v bao quanh tao hoc
cp.
Nn tin hnh th ti cng trng trc
m bo rng bin php v thit b
thi cng t c kt qu ra.
- Grout trn phi c s dng trong
vng 60 pht k t khi trn.
- Ty b ton APT 300 cha cng khi
dng c v thit b s dng bng nc.
Vi grout cng phi s dng c hc
ty b.
- i vi cng tc ly mu: i) Khun phi
c tram kn ngn grout b r i; ii)
Mu phi c ph bng nilon trnh
bay hi nc qu nhanh.
PACKAGE
- APT 300 ng trong bao 25kg.
- Thi gian s dng: 6 thng trong iu
kin kh ro v khng m cng nh l
kn kht.
AN TON, SC KHE, MI TRNG
- APT 300 c bn cht kim.
- Trnh tip xc trc tip vi mt.
- S dng gang tang v bo v mt trong
khi thi cng.
- Khi tip xc vi da, cn ra sch vi
nc.
DISCLAIM
Cc thng tin, bao gm nhng khng hn ch, hng
dn lin quan ti thi cng v s dng cui cng sn
phm APT 300 c cung cp l thin ch ca chng
ti da trn kinh nghim v hiu bit hin ti v iu
kin lu tr ng cch, thi cng v s dng trong
iu kin c bnh thng nh nu trn. Trong iu
kin thi cng thc t, chng ti khng m bo vic
s dng sn phm cho mt mc ch c th no
m c s khc bit v vt t, ct liu hay iu kin
thi cng cng nh khng c mt rng buc php l
no i vi chng ti hm t cc thng tin ny
hoc t mt hng dn bng vn bn hay bt k s
t vn no. Ngi s dng sn phm ny phi th
nghim nhm m bo rng sn phm c s dng
l ph hp vi mc ch cn. n v sn xut sn
phm c th thay i thng tin sn phm mnh.

MI CHI TIT XIN LIN H: CNG TY TNHH A&P PLUS


a ch: S nh 6B, l 11, khu tp th cng ty ng b 230 - C Bi - Gia Lm - H
Ni.
Cellphone: 0964.827.294

Email:

Info@anpplus.com

Website:anpplus.com

APT 300

ZERO BLEED, SAND FREE, CEMENTITIOUS


GROUT FOR POST-TENSIONED STRUCTURES

DESCRIPTIONS
Continue agitating the grout in the
APT 300 is a non-shrink, cementitious
container to achieve optimum flow.
Note: i) Water content can be dependent on
grout containing no chloride and does
speed of mixing, higher the rpm is the lower
not bleed even at high flow.
water content is; ii) Hand mix or low rotation rate
Use for horizontal and vertical grouting
are not recommended. However for low rotation
of ducts within bonded, post-tensioned
strirrer, water content is about 45% by weight
structures.
with longer mixing time (5 minutes or more to
get homogeneous).
APT 300 consists of anti-shrinkage and
superplastizing agents, which prevents - Grout is so pumped that it ensures
complete filling of the ducts and
shrinkage in both plastic and hardened
complete surroundings of the strands or
states.
bar.
SPECIFICATIONS
A mock-up on site is recommended to
- Grey/cement powder;
ensure that the placement means and
- Flowability (flow cone ASTM C939): 15 methods yield the specified results.
30 seconds
Mixed grout must be placed within 60
- Compressive strength:
minutes of mixing.
o 21 MPa at 7 days
Remove uncured APT 300 from tools
o 35 MPa at 28 days
and equipment with water. Hardened
- Setting time (ASTM C953): 6hrs - 12hrs
grout can only be removed mechanically.
- Volume change (ASTM C1090):
- For sampling: i) molds shall be sealed of
o 0.0%-0.1% at 24hrs
to prevent grout from leaking; ii)
o 0.2% at 28 days
specimens shall be covered with
- Bleeding (ASTM C940): 0% after 4 hours;
plastic/nylon sheets to avoid quick
- Wet density (ASTM C138): 1900-2000
evaporation.
Kg/m3;
PACKAGE
- Permeability (ASTM C1202): <2500
- APT 300 is packaged in 25kg bag.
couloms after 6hrs
- Chlorides content : <0.005% of density - Shelf life: six months in dry and
unopened condition.
of cement used.
HEALTH,
SAFETY AND ENVIROMENT
- Fluorides, sulphites, nitrates: none.
- Sand-free allows fillings into cavities and - APT 300 has alkali nature.
- Avoid contact with skin and eyes.
voids within the applied structure.
- Wear
protective
gloves
and
eye
APPLICATION
protection
during
application.
- Use for ducts, openings, inlets and
outlets within bonded, post-tensioned - If skin contact occurs, wash skin
thoroughly.
structures.
- Use for tight spaces where grouts DISCLAIM
All information furnished for this product including but
containing sand is difficult to flow.
not limited to, any recommendation and advice with
- Ducts, openings, inlets and outlets are
respect to the application and utilization is provided in
clean, free of dirt and debris, oils,
good faith based on A&P PLUS current experience and
kerosene and any other contaminants at
knowledge of the product when properly stored,
handled and applied under normal conditions in line
all times.
with instructions. In practice, the differences in
- Introduce 35-42.5% water by weight of
materials,
substrates,
storage
and
handling
grout to the mixer or container. Exact
conditions, actual site conditions and other factors out
water content shall be verified before
of A&P PLUSs control are such that A&P PLUS
using.
assumes no liability for the provision of such
- Add grout to the introduced water. It is
information, advice, recommendations or instructions
completely recommended to mix grout
related to its products, nor shall any legal relationship
by mixer or stir with rotation per minute
be created by or arise from the provision of such
of 1800 rpm and higher with shearinformation, advice, recommendations or instructions
related to its products. The user must test the product
cutting blades.
for suitability for the intended application and purpose
- Mix approximate 3 minutes after the
before proceeding with the full application of the
addition of the last bag or until a
product. A&P PLUS reserves the right to change the
homogeneous mix is achieved.
properties of its products without notice.

FOR MORE INFORMATION PLEASE CONTACT: A&P PLUS CO Ltd;


Add: Number 6B, lot 11, 230-roadway tenement Co Bi commune Gia Lam
district Hanoi
Cellphone: 0964.827.294

Email:

Info@anpplus.com

Website:anpplus.com

You might also like