APT 300
DESCRIPTIONS
Continue agitating the grout in the
APT 300 is a non-shrink, cementitious
container to achieve optimum flow.
Note: i) Water content can be dependent on
grout containing no chloride and does
speed of mixing, higher the rpm is the lower
not bleed even at high flow.
water content is; ii) Hand mix or low rotation rate
Use for horizontal and vertical grouting
are not recommended. However for low rotation
of ducts within bonded, post-tensioned
strirrer, water content is about 45% by weight
structures.
with longer mixing time (5 minutes or more to
get homogeneous).
APT 300 consists of anti-shrinkage and
superplastizing agents, which prevents - Grout is so pumped that it ensures
complete filling of the ducts and
shrinkage in both plastic and hardened
complete surroundings of the strands or
states.
bar.
SPECIFICATIONS
A mock-up on site is recommended to
- Grey/cement powder;
ensure that the placement means and
- Flowability (flow cone ASTM C939): 15 methods yield the specified results.
30 seconds
Mixed grout must be placed within 60
- Compressive strength:
minutes of mixing.
o 21 MPa at 7 days
Remove uncured APT 300 from tools
o 35 MPa at 28 days
and equipment with water. Hardened
- Setting time (ASTM C953): 6hrs - 12hrs
grout can only be removed mechanically.
- Volume change (ASTM C1090):
- For sampling: i) molds shall be sealed of
o 0.0%-0.1% at 24hrs
to prevent grout from leaking; ii)
o 0.2% at 28 days
specimens shall be covered with
- Bleeding (ASTM C940): 0% after 4 hours;
plastic/nylon sheets to avoid quick
- Wet density (ASTM C138): 1900-2000
evaporation.
Kg/m3;
PACKAGE
- Permeability (ASTM C1202): <2500
- APT 300 is packaged in 25kg bag.
couloms after 6hrs
- Chlorides content : <0.005% of density - Shelf life: six months in dry and
unopened condition.
of cement used.
HEALTH,
SAFETY AND ENVIROMENT
- Fluorides, sulphites, nitrates: none.
- Sand-free allows fillings into cavities and - APT 300 has alkali nature.
- Avoid contact with skin and eyes.
voids within the applied structure.
- Wear
protective
gloves
and
eye
APPLICATION
protection
during
application.
- Use for ducts, openings, inlets and
outlets within bonded, post-tensioned - If skin contact occurs, wash skin
thoroughly.
structures.
- Use for tight spaces where grouts DISCLAIM
All information furnished for this product including but
containing sand is difficult to flow.
not limited to, any recommendation and advice with
- Ducts, openings, inlets and outlets are
respect to the application and utilization is provided in
clean, free of dirt and debris, oils,
good faith based on A&P PLUS current experience and
kerosene and any other contaminants at
knowledge of the product when properly stored,
handled and applied under normal conditions in line
all times.
with instructions. In practice, the differences in
- Introduce 35-42.5% water by weight of
materials,
substrates,
storage
and
handling
grout to the mixer or container. Exact
conditions, actual site conditions and other factors out
water content shall be verified before
of A&P PLUSs control are such that A&P PLUS
using.
assumes no liability for the provision of such
- Add grout to the introduced water. It is
information, advice, recommendations or instructions
completely recommended to mix grout
related to its products, nor shall any legal relationship
by mixer or stir with rotation per minute
be created by or arise from the provision of such
of 1800 rpm and higher with shearinformation, advice, recommendations or instructions
related to its products. The user must test the product
cutting blades.
for suitability for the intended application and purpose
- Mix approximate 3 minutes after the
before proceeding with the full application of the
addition of the last bag or until a
product. A&P PLUS reserves the right to change the
homogeneous mix is achieved.
properties of its products without notice.
Email:
Info@anpplus.com
Website:anpplus.com