Service Mode (continued)


Error BLINKING Table
ES3

250ms

1) Power(RED) LED
Reason of the error

1sec

Remarks
Power(RED) LED Blink Timing (1 cycle)
H:LED ON

Lamp Error
1 time
Power supply Error
2 times
Main micom communication error
3 times

4 times
Temperature Error
5 times

Activation de la led OPC par la touche MENU

LED Blink Timing at ERROR STANDBY

L:LED OFF
H:LED ON
L:LED OFF
H:LED ON
L:LED OFF
H:LED ON
L:LED OFF
H:LED ON

Pin name ( number ) is monitor micom pin


ERR_PNL(43pin):Low error. It is settled by consecutive agreement 5 times at an interval for one second (detection only during the backlight lighting).
Please be careful to cannot starting except monitor process mode at accumulation five times. First is only inverter reset. Power is not off
Accumulation number of times is clear by Service-A setting, or body key [CH_DOWN]+[VOL_UP] push in AC_ON, or consecutive lighting three minutes.
Refer "2) Power supply error details"

Refer "3) Main micom communication error details"


Error in communication line or error in communication between Main micom. -> Confirm debug print of main micom.
Not used at Dijon

When panel temperature more than 60 degrees continued for 15 seconds, CAUTION OSD is displayed.
When panel temperature more than 60 degrees continued for 28 seconds, TV is changed to ERROR STANDBY.

L:LED OFF

2) Power supply error details ( Power(RED) LED 2 times + OPC LED )


OPC LED Blink Timing (1 cycle)
Reason of the error
H:LED ON
AC_DET
AC_DET line error
L:LED OFF
1 time

Remarks
Pin name ( number ) is monitor micom pin
AC_DET(16pin):Low error. AC_DET line does not turn to ON

H:LED ON

Detected at power-on sequence. When detected it by interrupt after power-on sequence, TV reboots.
Not used at Dijon

2 times
PS_ON
UR+15V line error
3 times
D_POW
D3.3V line error
4 times
PANEL_POW
PANEL_12V line error
5 times

L:LED OFF
H:LED ON

DET_10V(57pin):Low error. Main power supply(UR+15V) does not turn to ON

L:LED OFF
H:LED ON

Detected at power-on sequence. When detected it by poling after power-on sequence, TV reboots.
DET_D3V3(59pin):Low error. D3.3V power supply does not turn to ON

L:LED OFF
H:LED ON

Detected at power-on sequence. When detected it by poling after power-on sequence, TV reboots.
DET_PNL12V(58pin):Low error. Panel power does not turn to ON

L:LED OFF
H:LED ON

Detected at power-on sequence. When detected it by poling after power-on sequence, TV reboots.
Not used at Dijon

6 times

L:LED OFF
H:LED ON

Error from main micom


7 times

L:LED OFF

3) Main micom communication error details ( Power(RED) LED 3 times + OPC LED )
OPC LED Blink Timing (1 cycle)
Reason of the error
H:LED ON

Initial communication reception error


1 time
Start decision command reception error
2 times
Periodical communication error
3 times
Restart error
4 times

SEES Engineering Department

Error notified by Main micom ( FAN error , 1bitAMP error etc.


Details are displayed to the first page of Service-A mode.

L:LED OFF
H:LED ON
L:LED OFF
H:LED ON
L:LED OFF
H:LED ON

Remarks
Cannot receive the initial communication from main micom ( monitor model request command )
->Error in communication line or error in main maicom start process.
Cannot receive the start reason decision command from main micom
->Error in main micom start process, or Error in receive process in monitor micom.
Cannot receive Periodical communication that is send by main micom every one second when after power-on
->Error in main micom start process, or Error in receive process in monitor micom.
Cannot receive reboot completion command when TV is turn to "On" immediately after "off"
->Error in main micom re-start process, or Error in receive process in monitor micom.

L:LED OFF

Training course: X20 / XL2

18

ES3
Outline:

ERR_STBY Table
It can see the last four error reasons detected by monitor micom.
The error reason is stored to EEPROM and displayed at Service A mode.

3. Service Mode (continued)

Display place: The first page the 7th line of Service A mode, "MONITOR ERR CAUSE" item.

Monitor ERROR
"0" is Cause
displayedList
when no error. It can be cleared by "MONITOR ERROR CAUSE RESET" item at 32 page.
Display Error Reason
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24

Initial Communication Error 1


Initial Communication Error 2
Initial Communication Error 3
Initial Communication Error 4
Initial Communication Error 5
Initial Communication Error 6
Initial Communication Error 7
Initial Communication Error 8
Initial Communication Error 9
Communication Error A
Communication Error B
Communication Error C
Communication Error D
Communication Error E
Communication Error F
Communication Error G
Communication Error H
Communication Error I
Communication Error J
Communication Error K
Power(RED)LED Blink 0
Power(RED)LED Blink 1
Power(RED)LED Blink 2
Power(RED)LED Blink 3
Power(RED)LED Blink 4
Power(RED)LED Blink 5
Power(RED)LED Blink 6
Power(RED)LED Blink 7
Power supply Error 1
Power supply Error 2
Power supply Error 3
Power supply Error 4
Power supply Error 5
Power supply Error 6
Main micom Error
Power supply Error 7

SEES Engineering Department

Not used
Cannot receive initial communication from main CP
Receive initial communication only
To the communication setting reception
To the initialization completion reception
To the notice of version reception
To the notice of start information reception
To the start information answer reception
To the time-out setting reception
Request Timeout
Restart Timeout
End sequence Timeout
Reserve start Timeout when End seqence
Download Start Timeout
Get Time Start Timeout
Not used
Watchdog Timeout
Not used
Not used
Not used
Not used
Lamp Error
AC_DET Error
Not used
Not used
Monitor Temperature Error
Not used
Not used
PS_ON(DET_10V) Error
Not used
Not used
D_POW(DET_D3V3) Error
PanelPower Error
Not used
Error Standby request from Main CPU
AC_DET Error (during power on sequence)
Training course: X20 / XL2

code display page 1 du mode service

Power(RED)LED
Blink Times

OPC LED
Blink Times

3 times
3 times
3 times
3 times
3 times
3 times
3 times
3 times
3 times
3 times
Off
Off
3 times
Off

1 time
2 times
2 times
2 times
2 times
2 times
2 times
2 times
Off
4 times
Off
Off
Off
Off

3 times

3 times

1 time
2 times

Off
1 time

5 times

Off

2 times

3 times

2 times
2 times

4 times
5 times

2 times
2 times

7 times
1 time

19