Professional Documents
Culture Documents
TECHNICAL SPECIFICATIONS
LS-K CONTACTORS
FROM LS 75K TO LS 160K
INTERNATIONAL
RATINGS
Type
LS 75K
3 pole
Style
Rated insulation voltage U i
Rated impulse voltage Uimp
Mechanical endurance
AC - operation
Utilization category AC-1
Rated power value PN
V
kV
Operations
Operations
Mil
Per/H
3~ 230 V
3~ 400 V
3~ 500 V
3~ 690 V
3~1000V
kW
kW
kW
kW
KW
Amps
mm2
ops/h
A
kW
kW
kW
kW
kW
kW
Amps
ops/h
kW
kW
kW
kW
Amps
Ops/h
kW
A
1000
8
LS 90K
3 pole 4 pole
LS 110K
3 pole
Pollution degree 3
1000
8
1000
8
1000
8
1000
8
10
1200
10
1200
10
1200
114
196
259
341
517
315
185
600
252
114
196
259
341
517
315
185
600
252
10
10
1200
1200
Rated power values at resistive load
90
123
90
155
214
155
200
281
200
270
371
270
400
562
400
250
325
250
120
185
120
600
600
600
200
260
200
Rated power values of AC induction type motors
55
45
75
90
80
100
100
110
100
132
65
100
150
185
600
600
LS 160K
3 pole 4 pole
152
263
346
457
692
400
2X(25X5)
600
320
170
310
389
537
780
450
191
329
415
572
866
500
2X(30X5) 2X(25X5)
600
382
600
425
65
110
125
132
155
110
205
600
90
160
185
200
250
200
309
600
75
132
132
160
200
150
250
600
Rated power values of AC induction type motors (High Swithing, Plugging)
18,5
22
25
33
33
40
45
55
45
50
63
75
55
63
80
100
65
75
90
110
150
150
150
150
75
90
110
132
150
185
205
250
37
63
90
110
125
150
160
309
Rated power values of AC capacitors (minimum inductance between parallel connected capacitors 6 H)
3~ 230 V
3~ 400 V
kvar
kvar
A
A
VA
COS
Holding PHS
VA
COS
54
100
63
112
72
135
135
178
165.5
253
270
246
2 Slight welding of contacts that can easily be opened, is admitted but no further damages.
173
212
208
94
171
85
148
1) According to VDE 0660 part 102 / IEC 947 -4-1 coordination type permit the following damages:
52
LS 132K
3 pole 4 pole
500
309/205
50
315
250/185
50
500
315
500
315
250
500
425
20
-
750
25
-
425
20
-
350
3,5
650
4,5
350
3,5
60...70
13...17
70...80 60...70
70...80 60...70
70...80
70...80
60...70
13...17
70...80 60...70
70...80 60...70
70...80
70...80
253
270
246
253
270
246
173
212
208
173
212
208
750
25
650
4,5
INTERNATIONAL RATINGS
Thermal Overload Relay Type B05
for direct mounting onto contactors
type LS05, and LS07, also available
with adaptor for separate mounting.
Style and dimensions compatible with
contactors.
Technical Values
Type
LS05
SH05
Permissible ambient temperature
+60 C
Rated insulation voltage
660V
Mechanical lifespan
10,000,000
General Purpose Amps
20A
Permissible switching frequency 1200 ops/hr
Short-circuit protection(Class gL)
Highest rated fuse
20A
(without welding of contacts)
16A
Auxiliary switchHS05
220V 6A
AC-11-Duty Rated current
500V 2,5A
(a.c.)
600V 1,5A
24V 5A
DC-11-Duty Rated current
110V 1,2A
(d.c.)
220V 0,6A
Operating coil
(Standard -20% - +10%)
Closing 26VA
Power consumption Holding Phs
VA 4VA
Switching times at 1, 0 Us
1
(standard coil )
LS05 CONTACTOR
SH05 RELAY
B05 OVERLOAD RELAY
A stylish, and compact family of
control relays, type SH05, contactors,
type LS05, and overload relays, type
B05. Complete with a comprehensive
range of accessories, they provide the
flexible solution for control systems.
A maximum 10 pole control relay, type
SH05, with 6 auxiliary switches, is also
available as a contactor, type LS05
with up to 6 auxiliary switches. Rated at
5 HP 480V, it has a high switching performance within its compact dimensions.
Panel or DIN mountable.
Front mounting snap on auxiliary switch
block, with up to 4 contacts in standard
base module.
70
Contactor/Relay Accessories
A single pole auxiliary switch (1 N.O. or
1 N.C.) is available as an accessory, for
side mounting, thus avoiding any
increase in the high dimension.
Special auxiliary contacts for increased
contact reliability at low voltages.
Front or side mounting time delay
module 0.5 to 60 seconds.
Coil, overvoltage suppression module.
Mechanical interlock kit.
MINI-CONTACTORS
TYPE LS07
13/4
15/8
H.P. RATING
1 Phase
3 Phase
115V
230V
208V
230V
460V
AC OPERATED MINI CONTACTOR TYPE LS07
AMPS
(OPEN)
Resistive
Cat. No.
OPEN
LIST
TYPE M1
Auxiliary
NEMA1 TYPE 4X Contacts
LIST
LIST
NO NC
1
1
2
2
3
3
3
3
3
3
16A
16A
LS07.10LS07.01LS07.22
LS07.40
-0 $36
-0 36
-0 36
-0 36
3
3
3
3
16A
16A
LS07F.10LS07F.01-
-0 $36
-0 36
1
1
2
2
CONTACT
CODE
3
3
POWER
N.O.
N.C.
LS07.10
LS07.01
LS07.22
LS07.40
3
3
2
4
AUXILIARIES
N.O.
N.C.
2
-
1
-
1
-
SPADE CONNECTOR
(Single or Double Spade)
Check with factory for cost.
2
2
3
3
NOTE: In
Catalog No.
.10 indicates 1-NO Contact;
.01 indicates 1-NC Contact.
3
3
3
3
16A
16A
LS07.10LS07.01-
-0 $46
-0 46
3
3
3
3
16A
16A
LS07F.10LS07F.01-
-0 $46
-0 46
AC 60HZ
50HZ
DC
-A
120V
110V -MSW 12VDC
-C 208/230V 220V -NSW 24VDC
-D
380V -OSW 48VDC
-E
480V
440V -PSW 120VDC
-G
24V
22V -RSW 220VDC
+ $10 LIST
for DC Coil
SW Single Winding DC Power Plant
1
1
2
2
3
3
TYPE 4X ENCLOSED STARTERS. Type XLS starters are UL/CSA Listed starters enclosed in
type 4X U.L. Listed enclosures. Type 4X enclosures are designed for outdoor/hose down/
dust tight applications and are non-metal corrosion resistant.
CONTACT
CONFIGURATION
DESCRIPTION
Minicontactor Type LS07,
designed for motor control,
and distinct small size. As
such, they are recommended
for space saving in industrial
control, electronic control
and disribution systems.
The Type LS07
Minicontactor has been
proven dependable on both
three phase and single
01 E
Type LS 07.01
For TYPE LS05 - MINI Contactor, 20 Amp 600V, see LS05 Miniature Contactor System.
Discount Schedule ST
75
AC COILS
Catalog
Number
DC COILS
List
Each
Volt-Amp
Holding
VA
Catalog
Number
List
Each
Pick-up
Watt
Holding
Watt
LK-C 130-*
$20.00
26
LK-C 133-*
(at 24V)
$25.00
2.4
(1.2w)
2.4
(1.2w)
4K
5K
7K
11K
$23.00
45
LK-C 660-*
$50.00
5.5
5.5
LS 11K
LS 15K
LS 18K
LK-C 652-*
4 pole
3 + 4 pole
3 pole
$28.00
88
LK-C 662-*
$73.00
7.5
7.5
LS
LS
LS
LS
LK-C 653-*
4 pole
3 pole
3 + 4 pole
3 pole
$52.00
191
17
LK-C 663-*
$112.00
197
TW Two winding
2.6
$90.00
LS05
LS
LS
LS
LS
18K
22K
30K-45K
55K
LS 75K
LS 90K
3 pole
3 pole
LK-C 654-*
LS 55K
LS 110K
4 pole
3 pole
LK-C 655-*
$90.00
LS 90K
4 pole
LK-C 656-*
$90.00
Replacement Coils
Contactor Type
LS 75K
LS 90K
3 pole
3 pole
LS
LS
LS
LS
110K
160K
375K
55K
3
3
3
4
pole
pole
pole
pole
LS
LS
LS
LS
90K
132K
160K
375K
4 pole
4 pole
4 pole
4 pole
Coil with
Power Pack
LS 220K
LS 280K
3 + 4 pole
3 + 4 pole
LS 450K *
3 + 4 pole
Catalog
Number
List
Each
Contactor
Type
Catalog
Number
List
Each
$40.00
53.00
65.00
LS 11K
LS 15K
LS 18K
LK-CS 11-3P
LK-CS 15-3P
LK-CS 18-3P
43.00
62.00
72.00
90.00
108.00
165.00
260.00
$445.00
LK-C 667-*
$90.00
LS 22K
LS 30K
LS37K
LK-CS 22-3P
LK-CS 30-3P
LK-CS 37-3P
100.00
108.00
136.00
$445.00
LS 45K
LS 55K
LK-CS 45-3P
LK-CS 55-3P
172.00
208.00
LS
LS
LS
LS
LS
LK-CS
LK-CS
LK-CS
LK-CS
LK-CS
75-3P
90-3P
110-3P
132-3P
160-3P
229.00
287.00
363.00
433.00
543.00
LS 220K
LS 280K
LS 375K
LK-CS 220-3P
LK-CS 280-3P
LK-CS 375-3P
860.00
1240.00
1475.00
LS 450K
LK-CS 450-3P
2675.00
Power Pack
LK-CM 670-*
$445.00
LK-C 669-*
$576.00
LK-C 668-*
$238.00
* AC ONLY
* COIL VOLTAGE SUFFIX
SEE PAGE 57.
List
Each
$29.00
30.00
40.00
$90.00
$238.00
Catalog
Number
LK-CS 4-3P
LK-CS 5-3P
LK-CS 7-3P
LK-C 665-*
LK-C 670-*
Contactor
Type (-22 or-40)
LS 4K
LS 5K
LS 7K
Power Pack
LK-CM 672-*
Power Pack
LK-CM 671-*
Spare Contacts
REPLACEMENT CONTACTS
3 Pole Kits
62
Coil
Pick-up
VA
75K
90K
110K
132K
160K
* = Specify
-22 or
-40
AC OPERATED
LS 45K-4
LS 18K-4
LS 30K-4
LS 37K-4
(4 pole)
(4 pole)
117 (4.6)
Height
81 (3.2)
87 (3.4)
117 (4.6)
117 (4.6)
117 (4.6)
Width
45 (1.8)
55 (2.2)
66 (2.6)
75 (3)
87 (3.4)*
96 (3.8)*
Depth
83 (3.3)
98 (3.9)
116 (4.6)
126 (5.0)
118 (4.6)
126 (5.0)
Add for
top auxiliaries
+ 29 (1.2)
+ 29 (1.1)
Discount Schedule RP
AMPS (600V)
(3 Phase)
Voltage
AC-1
200
600 VOLT AC
UL/CSA
Inductive
230
460
600
7.5
10
10
15
32
32
7.5
15
15
45
32
10
10
20
25
60
54
10
10
25
25
90
55
20
20
50
50
110
100
Part
Number
List
Price
DIMENSIONS (mm)
without aux. contacts
W
25
25
D
LS5K-4-*
$92.00
81
45
85/115
LS5K-22-*
92.00
81
45
85/115
LS7K-4-*
94.00
81
45
85/115
LS7K-22-*
100.00
81
45
85/115
LS11K-4-*
110.00
87
55
98/134
LS11K-22-*
110.00
87
55
98/134
LS15K-4-*
195.00
87
55
98/134
LS15K-22-*
195.00
87
55
98/134
LS18K-4-*
240.00
118
87
119/147
LS18K-22-*
240.00
118
87
119/147
LS30K-4-*
340.00
118
87
119/147
LS30K-22-*
340.00
118
87
119/147
20
25
50
60
110
100
LS37K-22-*
398.00
118
87
119/147
25
30
60
75
140
140
LS45K-4-*
420.00
118
96
126/154
30
40
75
75
200
140
LS55K-4-*
627.00
200
150
176
50
60
125
125
325
156
LS90K-4-*
1,200.00
225
210
246
60
75
150
150
400
200
LS132K-4-*
1,745.00
225
210
246
100
100
200
300
500
310
LS160K-4-*
2,300.00
225
210
246
125
150
300
400
600
500
LS220K-4-*
2,650.00
218
214
228
150
200
400
500
700
650
LS280K-4-*
3,950.00
218
214
228
200
250
500
600
1000
810
LS375-4-*
5,400.00
250
269
304
350
450
900
900
1250
1215
LS450K-4-*
9,450.00
380
558
327
48
Standard
Auxiliary Contacts
(4-Pole Contactors)
Contactor
Standard
Auxiliary
LS4K - LS55K
Without
Auxiliary
LS90K - LS450K
LS37K-22-A
4 pole (2 N.O. / 2 N.C., 100 Amp.)
Discount Schedule ST
AC Depth/DC Depth
LS450K-4. 11-A
4 pole (N.O., 1250 Amp.)
1N.O., 1 N.C.
Size 00-2
AC-1
20
25
25
32
45
60
60
90
110
110
Horse Power
(UL) Ratings
3 Phase Voltage
AC-3
Max UL
Volts
HP
200V
3 HP
9
230V
3 HP
460V
5 HP
LIST $
12
18
25
32
40
50
65
80
200V
3 HP
230V
3 HP
460V
5 HP
600V
7.5 HP
LIST $
200V
3 HP
230V
3 HP
460V
7.5 HP
600V
10 HP
LIST $
200V
230V
460V
600V
LIST $
5 HP
5 HP
10 HP
15 HP
200V
5 HP
230V
7.5 HP
460V
15 HP
600V
15 HP
LIST $
200V
230V
460V
600V
LIST $
10
10
20
25
200V
230V
460V
600V
LIST $
10
10
25
25
200V
230V
460V
600V
LIST $
15
15
30
40
200V
230V
460V
600V
LIST $
20
20
40
50
200V
230V
460V
600V
LIST $
20
25
50
60
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
ENCLOSED
NEMA 1
General
Purpose
NEMA 4X
Outdoor
(non-metal)
NEMA 4
(metal)
NEMA 3R
(metal)
NEMA 12
Dust Tight
(metal)
LS05
-*O
$40.00
LS05
-*1
$109.00
LS05
-*4X
$132.00
LS05
-*4
$138.00
LS05
-*3R
$118.00
LS05
-*12
$118.00
LS4K
-*O
LS4K
-*1
LS4K
-*4X
LS4K
-*4
LS4K
-*3R
LS4K
-*12
$75.00
$144.00
$167.00
$187.00
$147.00
$147.00
LS5K
-*O
LS5K
-*1
LS5K
-*4X
LS5K
-*4
LS5K
-*3R
LS5K
-*12
$87.00
$156.00
$179.00
$199.00
$159.00
$159.00
LS7K
-*O
LS7K
-*1
LS7K
-*4X
LS7K
-*4
LS7K
-*3R
LS7K
-*12
$90.00
$159.00
$182.00
$202.00
$162.00
$162.00
LS11K
-*O
LS11K
-*1
LS11K
-*4X
LS11K
-*4
LS11K
-*3R
LS11K
-*12
$105.00
$174.00
$197.00
$217.00
$177.00
$177.00
LS15K
-*O
LS15K
-*1
LS15K
-*4X
LS15K
-*4
LS15K
-*3R
LS15K
-*12
$145.00
$214.00
$237.00
$257.00
$217.00
$217.00
LS18K
-*O
LS18K
-*1
LS18K
-*4X
LS18K
-*4
LS18K
-*3R
LS18K
-*12
$155.00
$224.00
$247.00
$267.00
$222.00
$222.00
LS22K.11
-*O
LS22K.11
-*1
LS22K.11
-*4X
LS22K.11
-*4
LS22K.11
-*3R
LS22K.11
-*12
$160.00
$229.00
$282.00
$302.00
$244.00
$244.00
LS30K
-*O
LS30K
-*1
LS30K
-*4X
LS30K
-*4
LS30K
-*3R
LS30K
-*12
$240.00
$309.00
$362.00
$553.00
$351.00
$351.00
LS37K
-*O
LS37K
-*1
LS37K
-*4X
LS37K
-*4
LS37K
-*3R
LS37K
-*12
$290.00
$359.00
$412.00
$629.00
$389.00
$389.00
OPEN
NEMA HP
See Below
200V
230V
460V
600V
NEMA
200V
230V
460V
600V
NEMA
1.5 HP
1.5 HP
2 HP
2 HP
00
3
3
5
5
0
HP
HP
HP
HP
200V
230V
460V
600V
NEMA
7.5 HP
7.5 HP
10 HP
10 HP
1
200V
230V
460V
600V
NEMA
10
15
25
25
2
HP
HP
HP
HP
To Order:
Example:
LS 220K
3 pole 4 pole
Style
Rated insulation voltage Uimp
Rated impulse voltage Uimp
Mechanical endurance
AC/DC
Operations
Operations
Utilization category AC-1
Rated power value PN
3~ 230 V
3~ 400 V
3~ 500 V
3~ 690 V
3~1000V
Rated current /e up to 690 V
Minimum wire cross-section under rated load /e
Admissible practical operation frequency
Rated current at 1000 ops/h
Utilization category AC-3
Rated power value PN
V
kV
LS 375K
3 pole
1000
-
LS 450K
3 pole 4 pole
1000
-
1000
-
10
900
3
600
381
658
866
1143
1732
1000
476
822
1082
1428
2165
1250
300
736
120
1125
kW
kW
kW
kW
kW
kW
Amps
ops/h
10
10
1200
1200
Rated power values at resistive load
266
228
460
395
606
519
800
686
1212
1039
700
600
2X(30X10) | 2X(40X10)
2X(30X8)
300
300
546
510
Rated power values of AC induction type motors
160
125
220
280
230
315
300
400
375
450
300
375
420
550
300
300
kW
kW
kW
kW
Amps
Ops/h
kW
A
Mil
Per/H
3~ 230 V
3~ 400 V
3~ 415/440 V
3~ 500 V
3~ 690 V
3~1000V
1000
-
LS 280K
3 pole 4 pole
kW
kW
kW
kW
KW
Amps
mm2
ops/h
A
220
375
400
480
500
450
700
300
250
450
450
500
550
500
825
120
kvar
kvar
A
A
VA
COS
Holding PHS
VA
COS
121
234
171
292
225
360
283
472
1250
825/700
50
160 | 214
220
228
1) According to VDE 0660 part 102 / IEC 947 -4-1 coordination type permit the following damages:
2 Slight welding of contacts that can easily be opened, is admitted but no further damages.
253
270
262
1250
1000
2760
6
-
50 ... 55
115 ... 130
312
265
304
464 | 581
380
327
53
V
kV
Operations
Operations
Mil
Mil
3~ 230 V
3~ 400 V
3~ 500 V
3~ 690 V
kW
kW
kW
kW
3~ 230 V
3~ 400 V
3~ 415 V
3~ 500 V
3~ 690 V
3~ 440 V
Amps
mm2
ops/h
A
kW
kW
kW
kW
kW
Amps
ops/h
kW
kW
kW
kW
3~ 400 V
3~ 400 V
Amps
ops/h
kW
A
3~ 230 V
3~ 400 V
3~ 525 V
3~ 690 V
kvar
kvar
kvar
kvar
A
A
LS 4K
3 pole
Pollution degree 3
1000
6
LS 5K
3 pole
4 pole
1000
6
15
15
15
15
Rated power values at resistive load
9.5
9.5
16.5
16.5
21,5
21,5
28,5
28,5
LS 7K
3 pole
4 pole
1000
6
1000
6
15
15
15
15
15
15
15
15
12
22
27,5
38
1,8
3,7
5,5
7,5
17
29
39
51
22,5
39,5
52
68,5
45
10
1200
45
60
16
1200
60
9
15
15
18,5
18,5
7,5
11
11
15
15
32
1200
25
1200
3,7
7,5
10
11
3
5,5
7,5
10
22,5
39,5
52
68,5
60
16
1200
60
4 pole
30
55
69
95
90
35
1200
90
11
18,5
22
25
30
40
1200
4
9
11
15
5
7
18,5
16
12
8
360
360
360
200
360
360
360
4
5,5
18,5
15
11
7,5
9
12
40
32
25
18
Rated power values of AC capacitors (minimum inductance between parallel connected capacitors 6 H)
3/3
2.5/2.5
3/3
10 /10)
7/6,5
12/12)
5/5
4 /4
5/5
)
16,7/16
13/11
20/20)
6/5
4 /4
6/5
20 /20)
17/13
25/25)
6/5
4 /4
6/5
19 /16,7)
17/12,5
20/20)
3 contacts connected in series (all DC-motors L/R 15 ms)
25
25
32
50
25
50
90
15
15
20
25
15
32
60
50
50
50
50
50
50
50
Maximum permissible fuse (operating category gL)
35
25
25
25
10
10
1) According to VDE 0660 part 102 / IEC 947 -4-1 coordination type permit the following damages:
2 Slight welding of contacts that can easily be opened, is admitted but no further damages.
50
LS 18K
3 pole
1000
6
12
18
9
1200
1200
1200
Rated power values of AC induction type motors
1,5
3
4
5,5
LS 15K
4 pole 3 pole 4 pole
1000
6
32
25
25
6
4
4
1200
1200
1200
32
25
25
Rated power values of AC induction type motors
2.2
3
4
4
5,5
7,5
4
5,5
7,5
5.5
7,5
10
5.5
7,5
10
1,1
2,2
3
4
LS 11K
3 pole
50
35
50
35
50
35
63
35
45
0,82
6
0,34
88
0,76
9
0,31
88
0,76
9
0,31
88
0,76
9
0,31
191
0,54
17
0,26
5,5
5,5
7,5
7,5
7,5
7,5
7,5
7,5
197
2,6
6 ... 25
6 ... 13
7 ... 25
5 ... 25
35... 65 35 ... 70
30... 60 40 ... 65
7 ... 25
5 ... 25
35 ... 70
40 ... 65
100
80
7... 25 9... 35
5... 25 9... 15
35... 70 15... 40
40... 65 9... 15
LS 22K
3 pole
Style
Rated insulation voltage U i
Rated impulse voltage Uimp
Mechanical endurance
AC - operation
DC - operation
Utilization category AC-1
Rated power value PN
V
kV
Operations
Operations
Mil
Mil
3~ 230 V
3~ 400 V
3~ 500 V
3~ 690 V
kW
kW
kW
kW
Amps
mm2
ops/h
A
Amps
ops/h
3~ 440 V
kW
kW
kW
kW
kW
LS 37K
3 pole 4 pole
Pollution degree 3
1000
8
15
15
15
15
Rated power values at resistive load
42
30
72,5
55
95
69
125
95
65
1200
LS 55K
3 pole
1000
8
1000
8
1000
8
15
15
15
15
15
15
42
72,5
95
125
110
110
90
35
35
35
1200
1200
1200
110
110
90
Rated power values of AC induction type motors
22
18,5
15
22
37
30
25
45
37
30
45
40
35
45
45
50
1200
LS 45K
3 pole 4 pole
80
1200
53
92
121
160
53
92
121
160
140
50
1200
112
140
50
1200
112
25
45
50
55
55
30
55
55
65
65
95
1200
105
1200
11
22
25
30
13
25
30
37
3~ 400 V
3~ 400 V
Amps
ops/h
kW
A
3~ 230 V
3~ 400 V
3~ 525 V
3~ 690 V
kvar
kvar
kvar
kvar
1000
8
LS 30K
3 pole 4 pole
A
A
5,5
11
15
18,5
7,5
15
18,5
22
10
18,5
22
25
30
50
44
23
37
200
200
200
200
200
30
55
45
22
37
65
105
95
50
80
Rated power values of AC capacitors (minimum inductance between parallel connected capacitors 6 H)
30/30
24/24
21/21
28/28
17/17
60/50
40/40
38/38
50/50
30/30
80/66
50/50
50/50
50/50
35/35
60/50
40/40
40/40
40/40
40/30
3 contacts connected in series (all DC-motors L/R 15 ms)
110
110
140
140
90
70
70
95
95
60
50
50
50
50
50
COMPONENT
CONTROLS
REVERSING STARTERS
and CONTACTORS
Complete line of open type and
enclosed controls
Mini Reversing Contactor
Type RLS7K-
NEMA Type 1
(metal)
NEMA 3R
NEMA 12
(metal)
(metal)
NEMA 4X
X-Proof
(fiberglass)
(contact factory)
Applications
Gear motors
Milling machines
Overhead garage doors
Presses
Conformity to Standards
REVERSING STARTERS
and CONTACTORS
55