You are on page 1of 10

TYPE LS-K CONTACTORS

TECHNICAL SPECIFICATIONS
LS-K CONTACTORS
FROM LS 75K TO LS 160K
INTERNATIONAL
RATINGS
Type

LS 75K
3 pole

Style
Rated insulation voltage U i
Rated impulse voltage Uimp
Mechanical endurance
AC - operation
Utilization category AC-1
Rated power value PN

V
kV
Operations
Operations

Mil
Per/H

3~ 230 V
3~ 400 V
3~ 500 V
3~ 690 V
3~1000V

kW
kW
kW
kW
KW
Amps
mm2
ops/h
A

Rated current /e up to 690 V


Minimum wire cross-section under rated load /e
Admissible practical operation frequency
Rated current at 1000 ops/h
Utilization category AC-3
Rated power value PN
3~ 230 V
3~ 400 V
3~ 415/440 V
3~ 500 V
3~ 690 V
3~1000V
Rated current /e up to 440 V
Admiss. switching freq. at PN and cont. cycling
Utilization category AC-4
Rated power value in PN
3~ 230 V
3~ 400 V
3~ 500 V
3~ 690 V
Rated current /e with practical electrical 3~ 690 V
endurance up to
Admissible switching frequency
3~ 400 V
Maximum permissible load PN
3~ 400 V
Utilization category AC-6b
Single / Parallel operation

kW
kW
kW
kW
kW
kW
Amps
ops/h
kW
kW
kW
kW
Amps
Ops/h
kW
A

1000
8

LS 90K
3 pole 4 pole

LS 110K
3 pole

Pollution degree 3
1000
8

1000
8

1000
8

1000
8

10
1200

10
1200

10
1200

114
196
259
341
517
315
185
600
252

114
196
259
341
517
315
185
600
252

10
10
1200
1200
Rated power values at resistive load
90
123
90
155
214
155
200
281
200
270
371
270
400
562
400
250
325
250
120
185
120
600
600
600
200
260
200
Rated power values of AC induction type motors
55
45
75
90
80
100
100
110
100
132
65
100
150
185
600
600

LS 160K
3 pole 4 pole

152
263
346
457
692
400
2X(25X5)
600
320

170
310
389
537
780
450

191
329
415
572
866
500

2X(30X5) 2X(25X5)

600
382

600
425

65
110
125
132
155
110
205
600

90
160
185
200
250
200
309
600

75
132
132
160
200
150
250
600
Rated power values of AC induction type motors (High Swithing, Plugging)
18,5
22
25
33
33
40
45
55
45
50
63
75
55
63
80
100
65
75
90
110
150
150
150
150
75
90
110
132
150
185
205
250

37
63
90
110
125
150
160
309

Rated power values of AC capacitors (minimum inductance between parallel connected capacitors 6 H)
3~ 230 V
3~ 400 V

DC-switching Rated current /e


DC-1 (resistive load)
24 ... 220 V /e
DC-3 / DC-5
24 ... 110 V /e
Admissible switching frequency (DC-1 ... DC-5)
Short Circuit protection of main contacts1)
Coordination type 2
no welding
Operating coil for AC-operation
Operating range 0,8 ... 1,1 Us Pick-up PAS

kvar
kvar
A
A

VA
COS

Holding PHS

VA
COS

Operating coil for DC-operation


Operating range 0,8 ... 1,1 Us
Pick-up PA
W
Holding PH
W
Switching items at AC-operation
Making delay
ms
Drop-out delay
ms
Switching items at DC-operation
Making delay
ms
Drop-out delay
ms
Dimensions
Without auxiliary contacts
Width mm
LS 75 ... LS 450K with .22
Height mm
Depth mm

54
100

63
112

72
135

Maximum permissible fuse (operating category gL)


250
400
250
315
200
160
250
Standard coil, power consumption at 50 Hz 1,0 Us
400
830
400
0,6
0,6
0,6
32
60
32
0,4
0,37
0,4
Standard coil, power consumption at 1,0 Us
135
650
350
135
3,5
4,5
3,5
3
Standard coil, power consumption at 1,0 Us
20...25
70...80
36 ... 40
20 ... 25
10...13
70...80
10 ... 15
10 ... 13
Standard coil, power consumption at 1,0 Us
60...70
70...80
60 ... 70
60 ... 70
13...17
70...80
13 ... 17
13 ... 17
135
178
165.5

135
178
165.5

253
270
246

2 Slight welding of contacts that can easily be opened, is admitted but no further damages.

173
212
208

94
171

85
148

3 contacts connected in series (all DC-motors L/R 15 ms)


315
250
250
205/150
185/105
150/95
50
50
50

1) According to VDE 0660 part 102 / IEC 947 -4-1 coordination type permit the following damages:

52

LS 132K
3 pole 4 pole

500
309/205
50

315
250/185
50

500
315

500

315
250

500

425
20
-

750
25
-

425
20
-

350
3,5

650
4,5

350
3,5

60...70
13...17

70...80 60...70
70...80 60...70

70...80
70...80

60...70
13...17

70...80 60...70
70...80 60...70

70...80
70...80

253
270
246

253
270
246

173
212
208

173
212
208

750
25
650
4,5

For technical specifications or larger K contactors


through LS450K (1250A), request from factory.

MINI CONTACTOR SYSTEM


TYPE LS05 - TYPE B05

20 AMP GENERAL PURPOSE

Type XLS05 STARTER


with Auxiliary Contacts

Type LS05 CONTACTOR

Type B05 OVERLOAD RELAY

INTERNATIONAL RATINGS
Thermal Overload Relay Type B05
for direct mounting onto contactors
type LS05, and LS07, also available
with adaptor for separate mounting.
Style and dimensions compatible with
contactors.

Technical Values
Type

LS05
SH05
Permissible ambient temperature
+60 C
Rated insulation voltage
660V
Mechanical lifespan
10,000,000
General Purpose Amps
20A
Permissible switching frequency 1200 ops/hr
Short-circuit protection(Class gL)
Highest rated fuse
20A
(without welding of contacts)
16A
Auxiliary switchHS05
220V 6A
AC-11-Duty Rated current
500V 2,5A
(a.c.)
600V 1,5A
24V 5A
DC-11-Duty Rated current
110V 1,2A
(d.c.)
220V 0,6A
Operating coil
(Standard -20% - +10%)
Closing 26VA
Power consumption Holding Phs
VA 4VA
Switching times at 1, 0 Us
1

(standard coil )

closing delay 7-12 MS


opening delay 6-13 MS

LS05 CONTACTOR
SH05 RELAY
B05 OVERLOAD RELAY
A stylish, and compact family of
control relays, type SH05, contactors,
type LS05, and overload relays, type
B05. Complete with a comprehensive
range of accessories, they provide the
flexible solution for control systems.
A maximum 10 pole control relay, type
SH05, with 6 auxiliary switches, is also
available as a contactor, type LS05
with up to 6 auxiliary switches. Rated at
5 HP 480V, it has a high switching performance within its compact dimensions.
Panel or DIN mountable.
Front mounting snap on auxiliary switch
block, with up to 4 contacts in standard
base module.

70

DIN rail mounting uses an adaptor plate.


The lower coil, and auxiliary switch connection
of the contactor is brought to a more
accessible terminal.
Ambient temperature compensation.
Single phase sensitivity is achieved by
a differential tripping action.

Contact life of the main contacts


The above diagram shows details of
the contact life in relation to the
breaking current, when switching
resistive and inductive a.c. loads. The
above does not relate to synchronising
of phase position during switching.
n = Contact Lifespan
Ic = Breaking current

Convertable Hand or Automatic reset


feature. (Reset button: blue).
Separate red *Stop* button.
One N.C. auxiliary trip switch built in,
with an additional *Snap* 1 N.O. auxiliary
trip switch available if required.

Contactor/Relay Accessories
A single pole auxiliary switch (1 N.O. or
1 N.C.) is available as an accessory, for
side mounting, thus avoiding any
increase in the high dimension.
Special auxiliary contacts for increased
contact reliability at low voltages.
Front or side mounting time delay
module 0.5 to 60 seconds.
Coil, overvoltage suppression module.
Mechanical interlock kit.

Type B05 Overload Relay


Tripping Characteristic(Example)
Curves show trip characteristic from cold
condition. From warm condition, the tripping
time can be reduced to approx. 25%.
(Average values for all current range)
* See page 73 for Dimensions.

MINI-CONTACTORS
TYPE LS07
13/4

POSITIVE GUIDED TYPE SH04 RELAYS


AND TYPE LS07 CONTACTORS
11/2

15/8

Certiifed as Positive Guided


AEG Relays and Contactors
1. Independent Test Lab Certified per IEC 947-5-1
2. 100% Quality Tested per IEC 947-5-1

H.P. RATING
1 Phase

3 Phase

115V
230V
208V
230V
460V
AC OPERATED MINI CONTACTOR TYPE LS07

AMPS
(OPEN)
Resistive

Cat. No.

OPEN
LIST

TYPE M1
Auxiliary
NEMA1 TYPE 4X Contacts
LIST
LIST
NO NC

With Pressure Wire Screw Terminals

1
1

2
2

3
3

3
3

3
3

16A
16A

LS07.10LS07.01LS07.22
LS07.40

-0 $36
-0 36
-0 36
-0 36

3
3

3
3

16A
16A

LS07F.10LS07F.01-

-0 $36
-0 36

With Flat Plug (Spade) Connectors

1
1

2
2

CONTACT
CODE

3
3
POWER
N.O.
N.C.

LS07.10
LS07.01
LS07.22
LS07.40

3
3
2
4

AUXILIARIES
N.O.
N.C.

2
-

1
-

1
-

SPADE CONNECTOR
(Single or Double Spade)
Check with factory for cost.

With Pressure Wire Screw Terminals

2
2

3
3

NOTE: In
Catalog No.
.10 indicates 1-NO Contact;
.01 indicates 1-NC Contact.

COIL VOLTAGE SUFFIX

DC OPERATED MINI CONTACTOR TYPE LS07


3 Pole Non-Reversing
1
1

-1 $105 -4X $128 1


-1 105 -4X 128 -

3
3

3
3

16A
16A

LS07.10LS07.01-

-0 $46
-0 46

3
3

3
3

16A
16A

LS07F.10LS07F.01-

-0 $46
-0 46

AC 60HZ
50HZ
DC
-A
120V
110V -MSW 12VDC
-C 208/230V 220V -NSW 24VDC
-D
380V -OSW 48VDC
-E
480V
440V -PSW 120VDC
-G
24V
22V -RSW 220VDC
+ $10 LIST
for DC Coil
SW Single Winding DC Power Plant

With Flat Plug (Spade) Connectors

1
1

2
2

3
3

TYPE 4X ENCLOSED STARTERS. Type XLS starters are UL/CSA Listed starters enclosed in
type 4X U.L. Listed enclosures. Type 4X enclosures are designed for outdoor/hose down/
dust tight applications and are non-metal corrosion resistant.

CONTACT
CONFIGURATION

DESCRIPTION
Minicontactor Type LS07,
designed for motor control,
and distinct small size. As
such, they are recommended
for space saving in industrial
control, electronic control
and disribution systems.
The Type LS07
Minicontactor has been
proven dependable on both
three phase and single

phase systems when controlling motor loads. LS07


is particularly recommended
for metal and woodworking
machines, for textile and
construction machinery and
other commercial and
industrial applications.
Other loads for minicontactors are resistive, such as
heating and lighting circuits,
or inductive loads repre-

sented by solenoid valves


and clutch couplings.
10 E
Type LS 07.10

01 E
Type LS 07.01

For TYPE LS05 - MINI Contactor, 20 Amp 600V, see LS05 Miniature Contactor System.
Discount Schedule ST

75

REPLACEMENT COILS &


CONTACT KITS (K SERIES)
SPARE PARTS
Replacement Coils
Contactor
Type

AC COILS
Catalog
Number

DC COILS
List
Each

Volt-Amp
Holding
VA

Catalog
Number

List
Each

Pick-up
Watt

Holding
Watt

LK-C 130-*

$20.00

26

LK-C 133-*
(at 24V)

$25.00

2.4
(1.2w)

2.4
(1.2w)

4K
5K
7K
11K

3 + 4 pole LK-C 650-*


3 + 4 pole
3 + 4 pole
3 pole

$23.00

45

LK-C 660-*

$50.00

5.5

5.5

LS 11K
LS 15K
LS 18K

LK-C 652-*
4 pole
3 + 4 pole
3 pole

$28.00

88

LK-C 662-*

$73.00

7.5

7.5

LS
LS
LS
LS

LK-C 653-*
4 pole
3 pole
3 + 4 pole
3 pole

$52.00

191

17

LK-C 663-*

$112.00

197
TW Two winding

2.6

$90.00

LS05
LS
LS
LS
LS

18K
22K
30K-45K
55K

LS 75K
LS 90K

3 pole
3 pole

LK-C 654-*

LS 55K
LS 110K

4 pole
3 pole

LK-C 655-*

$90.00

LS 90K

4 pole

LK-C 656-*

$90.00

Replacement Coils
Contactor Type
LS 75K
LS 90K

3 pole
3 pole

LS
LS
LS
LS

110K
160K
375K
55K

3
3
3
4

pole
pole
pole
pole

LS
LS
LS
LS

90K
132K
160K
375K

4 pole
4 pole
4 pole
4 pole

Coil with
Power Pack
LS 220K
LS 280K

3 + 4 pole
3 + 4 pole

LS 450K *

3 + 4 pole

Catalog
Number

List
Each

Kit includes 2 stationary & 1 movable


contact for each pole with spring.

4 Pole Kits (-22 or -4)

Contactor
Type

Catalog
Number

List
Each

LS 5K-22 or 40 LK-CS 5C-*


LS 7K-22 or 40 LK-CS 7C-*
LS11K-22 or 40 LK-CS 11C-*

$40.00
53.00
65.00

LS 11K
LS 15K
LS 18K

LK-CS 11-3P
LK-CS 15-3P
LK-CS 18-3P

43.00
62.00
72.00

LS15K-22 or 40 LK-CS 15C-*


LS18K-22 or 40 LK-CS 18C-*
LS 30K-22 or 40 LK-CS 30C-*

90.00
108.00
165.00

LS 37K-22 or 40 LK-CS 37C-*

260.00

$445.00

LK-C 667-*

$90.00

LS 22K
LS 30K
LS37K

LK-CS 22-3P
LK-CS 30-3P
LK-CS 37-3P

100.00
108.00
136.00

$445.00

LS 45K
LS 55K

LK-CS 45-3P
LK-CS 55-3P

172.00
208.00

LS
LS
LS
LS
LS

LK-CS
LK-CS
LK-CS
LK-CS
LK-CS

75-3P
90-3P
110-3P
132-3P
160-3P

229.00
287.00
363.00
433.00
543.00

LS 220K
LS 280K
LS 375K

LK-CS 220-3P
LK-CS 280-3P
LK-CS 375-3P

860.00
1240.00
1475.00

LS 450K

LK-CS 450-3P

2675.00

Power Pack
LK-CM 670-*

$445.00

LK-C 669-*

$576.00

LK-C 668-*

$238.00

* AC ONLY
* COIL VOLTAGE SUFFIX
SEE PAGE 57.

* DC OPERATED same dimensions, except with


DC coil switching auxiliary, and 11 mm (0.43)

List
Each

$29.00
30.00
40.00

$90.00

$238.00

Catalog
Number

LK-CS 4-3P
LK-CS 5-3P
LK-CS 7-3P

LK-C 665-*

LK-C 670-*

Contactor
Type (-22 or-40)

LS 4K
LS 5K
LS 7K

Power Pack
LK-CM 672-*

Power Pack
LK-CM 671-*

Spare Contacts

REPLACEMENT CONTACTS

3 Pole Kits

AC/DC CONTACTOR COILS

62

Coil
Pick-up
VA

75K
90K
110K
132K
160K

* = Specify
-22 or
-40

LSK CONTACTOR DIMENSIONS, Approximate mm (inches)


LS 45K
Contactor
LS 4K, 5K
LS 11K-4
LS 22K
LS 55K
Part Number LS 7K, 11K
LS 15K-4
LS 30K
3 pole
11K = 3Pole
LS 15K
LS 37K
(3 pole)
(-4 is 4 pole) (3 + 4 pole)
LS 18K
(3 pole)

AC OPERATED
LS 45K-4
LS 18K-4
LS 30K-4
LS 37K-4
(4 pole)
(4 pole)
117 (4.6)

Height

81 (3.2)

87 (3.4)

117 (4.6)

117 (4.6)

117 (4.6)

Width

45 (1.8)

55 (2.2)

66 (2.6)

75 (3)

87 (3.4)*

96 (3.8)*

Depth

83 (3.3)

98 (3.9)

116 (4.6)

126 (5.0)

118 (4.6)

126 (5.0)

Add for
top auxiliaries

+ 29 (1.2)

+ 29 (1.1)

Discount Schedule RP

TYPE LS-K 4-POLE


AC CONTACTORS
4 N.O POWER POLES (CODE - 4)
2 N.O. & 2 N.C. POWER POLES (CODE - 22)
Max Horsepower

AMPS (600V)

(3 Phase)
Voltage
AC-1
200

600 VOLT AC

UL/CSA
Inductive

230

460

600

7.5

10

10

15

32

32

7.5

15

15

45

32

10

10

20

25

60

54

10

10

25

25

90

55

20

20

50

50

110

100

Part
Number

List
Price

DIMENSIONS (mm)
without aux. contacts
W

25

25

D

LS5K-4-*

$92.00

81

45

85/115

LS5K-22-*

92.00

81

45

85/115

LS7K-4-*

94.00

81

45

85/115

LS7K-22-*

100.00

81

45

85/115

LS11K-4-*

110.00

87

55

98/134

LS11K-22-*

110.00

87

55

98/134

LS15K-4-*

195.00

87

55

98/134

LS15K-22-*

195.00

87

55

98/134

LS18K-4-*

240.00

118

87

119/147

LS18K-22-*

240.00

118

87

119/147

LS30K-4-*

340.00

118

87

119/147

LS30K-22-*

340.00

118

87

119/147

20

25

50

60

110

100

LS37K-22-*

398.00

118

87

119/147

25

30

60

75

140

140

LS45K-4-*

420.00

118

96

126/154

30

40

75

75

200

140

LS55K-4-*

627.00

200

150

176

50

60

125

125

325

156

LS90K-4-*

1,200.00

225

210

246

60

75

150

150

400

200

LS132K-4-*

1,745.00

225

210

246

100

100

200

300

500

310

LS160K-4-*

2,300.00

225

210

246

125

150

300

400

600

500

LS220K-4-*

2,650.00

218

214

228

150

200

400

500

700

650

LS280K-4-*

3,950.00

218

214

228

200

250

500

600

1000

810

LS375-4-*

5,400.00

250

269

304

350

450

900

900

1250

1215

LS450K-4-*

9,450.00

380

558

327

NOTE: Above contactors, LS5K - LS55K are supplied without auxiliaries.


* COIL SUFFIX - Select coil from chart on the previous page.
For accessories - see page 61.

48

Standard
Auxiliary Contacts
(4-Pole Contactors)
Contactor

Standard
Auxiliary

LS4K - LS55K

Without
Auxiliary

LS90K - LS450K

LS37K-22-A
4 pole (2 N.O. / 2 N.C., 100 Amp.)
Discount Schedule ST

 AC Depth/DC Depth

LS450K-4. 11-A
4 pole (N.O., 1250 Amp.)

1N.O., 1 N.C.

Accessories on page 61.

TYPE LSK AC 3 POLE CONTACTORS


3 Phase Full Voltage-Across the Line
NEMA
RATED

Size 00-2

AC-1

20

25

25

32

45

60

60

90

110

110

Horse Power
(UL) Ratings
3 Phase Voltage
AC-3
Max UL
Volts
HP
200V
3 HP
9
230V
3 HP
460V
5 HP
LIST $

12

18

25

32

40

50

65

80

200V
3 HP
230V
3 HP
460V
5 HP
600V
7.5 HP
LIST $
200V
3 HP
230V
3 HP
460V
7.5 HP
600V
10 HP
LIST $
200V
230V
460V
600V
LIST $

5 HP
5 HP
10 HP
15 HP

200V
5 HP
230V
7.5 HP
460V
15 HP
600V
15 HP
LIST $
200V
230V
460V
600V
LIST $

10
10
20
25

200V
230V
460V
600V
LIST $

10
10
25
25

200V
230V
460V
600V
LIST $

15
15
30
40

200V
230V
460V
600V
LIST $

20
20
40
50

200V
230V
460V
600V
LIST $

20
25
50
60

HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP

HP
HP
HP
HP
HP
HP
HP
HP

ENCLOSED
NEMA 1
General
Purpose

NEMA 4X 
Outdoor
(non-metal)

NEMA 4

(metal)

NEMA 3R
(metal)

NEMA 12
Dust Tight
(metal)

LS05
-*O
$40.00

LS05
-*1
$109.00

LS05
-*4X
$132.00

LS05
-*4
$138.00

LS05
-*3R
$118.00

LS05
-*12
$118.00

LS4K
-*O

LS4K
-*1

LS4K
-*4X

LS4K
-*4

LS4K
-*3R

LS4K
-*12

$75.00

$144.00

$167.00

$187.00

$147.00

$147.00

LS5K
-*O

LS5K
-*1

LS5K
-*4X

LS5K
-*4

LS5K
-*3R

LS5K
-*12

$87.00

$156.00

$179.00

$199.00

$159.00

$159.00

LS7K
-*O

LS7K
-*1

LS7K
-*4X

LS7K
-*4

LS7K
-*3R

LS7K
-*12

$90.00

$159.00

$182.00

$202.00

$162.00

$162.00

LS11K
-*O

LS11K
-*1

LS11K
-*4X

LS11K
-*4

LS11K
-*3R

LS11K
-*12

$105.00

$174.00

$197.00

$217.00

$177.00

$177.00

LS15K
-*O

LS15K
-*1

LS15K
-*4X

LS15K
-*4

LS15K
-*3R

LS15K
-*12

$145.00

$214.00

$237.00

$257.00

$217.00

$217.00

LS18K
-*O

LS18K
-*1

LS18K
-*4X

LS18K
-*4

LS18K
-*3R

LS18K
-*12

$155.00

$224.00

$247.00

$267.00

$222.00

$222.00

LS22K.11
-*O

LS22K.11
-*1

LS22K.11
-*4X

LS22K.11
-*4

LS22K.11
-*3R

LS22K.11
-*12

$160.00

$229.00

$282.00

$302.00

$244.00

$244.00

LS30K
-*O

LS30K
-*1

LS30K
-*4X

LS30K
-*4

LS30K
-*3R

LS30K
-*12

$240.00

$309.00

$362.00

$553.00

$351.00

$351.00

LS37K
-*O

LS37K
-*1

LS37K
-*4X

LS37K
-*4

LS37K
-*3R

LS37K
-*12

$290.00

$359.00

$412.00

$629.00

$389.00

$389.00

OPEN

NEMA HP

See Below

200V
230V
460V
600V
NEMA

200V
230V
460V
600V
NEMA

1.5 HP
1.5 HP
2 HP
2 HP
00

3
3
5
5
0

HP
HP
HP
HP

200V
230V
460V
600V
NEMA

7.5 HP
7.5 HP
10 HP
10 HP
1

200V
230V
460V
600V
NEMA

10
15
25
25
2

HP
HP
HP
HP

Modifications and accessories are listed on pages

To Order:

Example:

5 HP 230V load with a 120VAC Coil, NEMA 1


Select from the Horse Power voltage list the appropiate contactor
Enclosure
size. Once the size is determined, contactor coil suffix must be
Part#: LS7K-A1 $159.00 List
designated from the chart on next page.
pg.46
Discount Schedule ST

TYPE LS-K CONTACTORS


TECHNICAL SPECIFICATIONS
LS-K CONTACTORS
FROM LS 220K TO LS 450K
INTERNATIONAL
RATINGS
Type

LS 220K
3 pole 4 pole

Style
Rated insulation voltage Uimp
Rated impulse voltage Uimp
Mechanical endurance
AC/DC
Operations
Operations
Utilization category AC-1
Rated power value PN
3~ 230 V
3~ 400 V
3~ 500 V
3~ 690 V
3~1000V
Rated current /e up to 690 V
Minimum wire cross-section under rated load /e
Admissible practical operation frequency
Rated current at 1000 ops/h
Utilization category AC-3
Rated power value PN

V
kV

Rated current /e up to 440 V


Admiss. switching freq. at PN and cont. cycling
Utilization category AC-4
Rated power value in PN
3~ 230 V
3~ 400 V
3~ 500 V
3~ 690 V
Rated current /e with practical element 3~ 1000 V
endurance up to
Admissible switching frequency
3~ 400 V
Maximum permissible load PN
3~ 400 V
Utilization category AC-6b
Single / Parallel operation

LS 375K
3 pole

1000
-

LS 450K
3 pole 4 pole

1000
-

1000
-

10
900

3
600

381
658
866
1143
1732
1000

476
822
1082
1428
2165
1250

300
736

120
1125

kW
kW
kW
kW
kW
kW
Amps
ops/h

10
10
1200
1200
Rated power values at resistive load
266
228
460
395
606
519
800
686
1212
1039
700
600
2X(30X10) | 2X(40X10)
2X(30X8)
300
300
546
510
Rated power values of AC induction type motors
160
125
220
280
230
315
300
400
375
450
300
375
420
550
300
300

kW
kW
kW
kW
Amps
Ops/h
kW
A

Rated power values of AC induction motors (high switching, plugging duty)


80
45
110
50
132
80
165
90
225
100
250
110
250
132
315
150
250
150
350
165
120
150
120
150
375
220
450
280
700
420
825
550

Mil
Per/H

3~ 230 V
3~ 400 V
3~ 415/440 V
3~ 500 V
3~ 690 V
3~1000V

1000
-

LS 280K
3 pole 4 pole

kW
kW
kW
kW
KW
Amps
mm2
ops/h
A

220
375
400
480
500
450
700
300

250
450
450
500
550
500
825
120

Rated values of AC capacitors (minimum inductance between parallel connected capacitors 6 H)


3~ 230 V
3~ 400 V

DC-switching Rated current /e


DC-1 (resistive load)
24 ... 220 V /e
DC-3 / DC-5
24 ... 110 V /e
Admissible switching frequency (DC-1 ... DC-5)
Short Circuit protection of main contacts1)
Coordination type 2
no welding
Operating coil for AC-operation
Operating range 0,8 ... 1,1 Us Pick-up PAS

kvar
kvar
A
A

VA
COS

Holding PHS

VA
COS

Operating coil for DC-operation


Operating range 0,8 ... 1,1 Us
Pick-up PA
W
Holding PH
W
Switching items at AC-operation
Making delay
ms
Drop-out delay
ms
Switching items at DC-operation
Making delay
ms
Drop-out delay
ms
Dimensions
Without auxiliary contacts
Width mm
LS 75 ... LS 450K with .22
Height mm
Depth mm

121
234

171
292

225
360

283
472

3 contacts connected in series (all DC-motors L/R 15 ms)


1000
700
600
700/400
550/300
420/250
50
50
50

1250
825/700
50

Maximum permissible fuse (operating category gL)


800
630
1000
500
400
630
Standard coil, power consumption at 50 Hz 1,0 Us
680
750
680
23
25
23
Standard coil, power consumption at 1,0 Us
600
600
600
4
4,5
4
Standard coil, power consumption at 1,0 Us
80 ... 90
70 ... 80
80 ... 90
40 ... 50
70 ... 80
40 ... 50
Standard coil, power consumption at 1,0 Us
80 ... 90
80 ... 90
40 ... 50
40 ... 50
160 | 214
220
228

160 | 214
220
228

1) According to VDE 0660 part 102 / IEC 947 -4-1 coordination type permit the following damages:
2 Slight welding of contacts that can easily be opened, is admitted but no further damages.

253
270
262

1250
1000
2760
6
-

50 ... 55
115 ... 130
312
265
304

464 | 581
380
327

For technical specifications or larger K


contactors through LS450K (1250A),
request from factory.

53

TYPE LS-K CONTACTORS


TECHNICAL SPECIFICATIONS
LS-K CONTACTORS
FROM LS 4K TO LS 18K
INTERNATIONAL
RATINGS
Type
Style
Rated insulation voltage U i
Rated impulse voltage Uimp
Mechanical endurance
AC - operation
DC - operation
Utilization category AC-1
Rated power value PN

V
kV
Operations
Operations

Mil
Mil

3~ 230 V
3~ 400 V
3~ 500 V
3~ 690 V

kW
kW
kW
kW

Rated current /e up to 690 V


Minimum wire cross-section under rated load /e
Admissible practical operation frequency
Rated current at 1000 ops/h
Utilization category AC-3
Rated power value PN

3~ 230 V
3~ 400 V
3~ 415 V
3~ 500 V
3~ 690 V

Rated current /e up to 440 V


Admiss. switching freq. at PN and cont. cycling
Utilization category AC-4
Rated power value PN
3~ 230 V
3~ 400 V
3~ 500 V
3~ 690 V
Rated current /e with practical electrical
endurance up to
Admissible switching frequency
Maximum permissible load PN
/e
Utilization category AC-6b
Single / Parallel operation

3~ 440 V

Amps
mm2
ops/h
A
kW
kW
kW
kW
kW
Amps
ops/h
kW
kW
kW
kW

3~ 400 V
3~ 400 V

Amps
ops/h
kW
A

3~ 230 V
3~ 400 V
3~ 525 V
3~ 690 V

kvar
kvar
kvar
kvar

DC-switching Rated current /e


DC-1 (resistive load)
24 ... 220 V /e
DC-3 / DC-5
24 ... 110 V /e
Admissible switching frequency (DC-1 ... DC-5)
Short Circuit protection of main contacts1)
Coordination type 2
no welding
Operating coil for AC-operation
Operating range 0,8 ... 1,1 Us Pick-up PAS

A
A

LS 4K
3 pole
Pollution degree 3
1000
6

LS 5K
3 pole

4 pole

1000
6

15
15
15
15
Rated power values at resistive load
9.5
9.5
16.5
16.5
21,5
21,5
28,5
28,5

LS 7K
3 pole

4 pole

1000
6

1000
6

15
15

15
15

15
15

15
15

12
22
27,5
38

1,8
3,7
5,5
7,5

17
29
39
51

22,5
39,5
52
68,5

45
10
1200
45

60
16
1200
60
9
15
15
18,5
18,5

7,5
11
11
15
15

32
1200

25
1200

3,7
7,5
10
11

3
5,5
7,5
10

22,5
39,5
52
68,5
60
16
1200
60

4 pole

30
55
69
95
90
35
1200
90

11
18,5
22
25
30
40
1200
4
9
11
15

5
7
18,5
16
12
8
360
360
360
200
360
360
360
4
5,5
18,5
15
11
7,5
9
12
40
32
25
18
Rated power values of AC capacitors (minimum inductance between parallel connected capacitors 6 H)
3/3
2.5/2.5
3/3
10 /10)
7/6,5
12/12)
5/5
4 /4
5/5
)
16,7/16
13/11
20/20)
6/5
4 /4
6/5
20 /20)
17/13
25/25)
6/5
4 /4
6/5
19 /16,7)
17/12,5
20/20)
3 contacts connected in series (all DC-motors L/R 15 ms)
25
25
32
50
25
50
90
15
15
20
25
15
32
60
50
50
50
50
50
50
50
Maximum permissible fuse (operating category gL)
35
25
25
25
10
10

Standard coil, power consumption at 50 Hz 1,0 Us


45
45
45
COS
0,82
0,82
0,82
6
Holding PHS VA
6
6
0,34
0,34
COS
0,34
Operating coil for DC-operation
Standard coil, power consumption at 1,0 Us
Operating range 0,8 ... 1,1 Us
Pick-up PA
W
5,5
5,5
5,5
5,5
W
Holding PH
5,5
5,5
Switching items at AC-operation
Standard coil, power consumption at 1,0 Us
6 ... 25
6 ... 25
6 ... 25
Making delay
ms
6 ... 13
6 ... 13
6 ... 13
Drop-out delay
ms
Switching items at DC-operation
Standard coil, power consumption at 1,0 Us
35 ... 65
Making delay
ms
35 ... 65
35 ... 65
30 ... 60
Drop-out delay
ms
30 ... 60
30 ... 60
VA

1) According to VDE 0660 part 102 / IEC 947 -4-1 coordination type permit the following damages:
2 Slight welding of contacts that can easily be opened, is admitted but no further damages.

50

LS 18K
3 pole

1000
6

12
18
9
1200
1200
1200
Rated power values of AC induction type motors
1,5
3
4
5,5

LS 15K
4 pole 3 pole 4 pole

1000
6

32
25
25
6
4
4
1200
1200
1200
32
25
25
Rated power values of AC induction type motors
2.2
3
4
4
5,5
7,5
4
5,5
7,5
5.5
7,5
10
5.5
7,5
10

1,1
2,2
3
4

LS 11K
3 pole

2) Minimum inductance between parallel connected capacitor 20 H

50
35

50
35

50
35

63
35

45
0,82
6
0,34

88
0,76
9
0,31

88
0,76
9
0,31

88
0,76
9
0,31

191
0,54
17
0,26

5,5
5,5

7,5
7,5

7,5
7,5

7,5
7,5

197
2,6

6 ... 25
6 ... 13

7 ... 25
5 ... 25

35... 65 35 ... 70
30... 60 40 ... 65

7 ... 25
5 ... 25
35 ... 70
40 ... 65

100
80

7... 25 9... 35
5... 25 9... 15
35... 70 15... 40
40... 65 9... 15

TYPE LS-K CONTACTORS


TECHNICAL SPECIFICATIONS
LS-K CONTACTORS
FROM LS 22K TO LS 55K
INTERNATIONAL
RATINGS
Type

LS 22K
3 pole

Style
Rated insulation voltage U i
Rated impulse voltage Uimp
Mechanical endurance
AC - operation
DC - operation
Utilization category AC-1
Rated power value PN

V
kV
Operations
Operations

Mil
Mil

3~ 230 V
3~ 400 V
3~ 500 V
3~ 690 V

kW
kW
kW
kW

Rated current /e up to 690 V


Minimum wire cross-section under rated load /e
Admissible practical operation frequency
Rated current at 1000 ops/h
Utilization category AC-3
Rated power value PN
3~ 230 V
3~ 400 V
3~ 415 V
3~ 500 V
3~ 690 V

Amps
mm2
ops/h
A

Rated current /e up to 440 V


Admiss. switching freq. at PN and cont. cycling
Utilization category AC-4
Rated power value in PN
3~ 230 V
3~ 400 V
3~ 500 V
3~ 690 V

Amps
ops/h

Rated current /e with practical electrical


endurance up to
Admissible switching frequency
Maximum permissible load PN
/e
Utilization category AC-6b
Single / Parallel operation

3~ 440 V

kW
kW
kW
kW
kW

LS 37K
3 pole 4 pole

Pollution degree 3
1000
8

15
15
15
15
Rated power values at resistive load
42
30
72,5
55
95
69
125
95

65
1200

LS 55K
3 pole

1000
8

1000
8

1000
8

15
15

15
15

15
15

42
72,5
95
125

110
110
90
35
35
35
1200
1200
1200
110
110
90
Rated power values of AC induction type motors
22
18,5
15
22
37
30
25
45
37
30
45
40
35
45
45
50
1200

LS 45K
3 pole 4 pole

80
1200

53
92
121
160

53
92
121
160

140
50
1200
112

140
50
1200
112

25
45
50
55
55

30
55
55
65
65

95
1200

105
1200

11
22
25
30

13
25
30
37

Rated power values of AC induction type motors


kW
kW
kW
kW

3~ 400 V
3~ 400 V

Amps
ops/h
kW
A

3~ 230 V
3~ 400 V
3~ 525 V
3~ 690 V

kvar
kvar
kvar
kvar

DC-switching Rated current /e


DC-1 (resistive load)
24 ... 220 V /e
DC-3 / DC-5
24 ... 110 V /e
Admissible switching frequency (DC-1 ... DC-5)

1000
8

LS 30K
3 pole 4 pole

A
A

5,5
11
15
18,5

7,5
15
18,5
22

10
18,5
22
25

30
50
44
23
37
200
200
200
200
200
30
55
45
22
37
65
105
95
50
80
Rated power values of AC capacitors (minimum inductance between parallel connected capacitors 6 H)
30/30
24/24
21/21
28/28
17/17
60/50
40/40
38/38
50/50
30/30
80/66
50/50
50/50
50/50
35/35
60/50
40/40
40/40
40/40
40/30
3 contacts connected in series (all DC-motors L/R 15 ms)
110
110
140
140
90
70
70
95
95
60
50
50
50
50
50

Maximum permissible fuse (operating category gL)


125
100
200
125
200
100
80
160
100
160
Standard coil, power consumption at 50 Hz 1,0 Us
VA
191
191
191
191
191
0,54
COS
0,54
0,54
0,54
0,54
17
17
Holding PHS VA
17
17
17
0,26
0,26
0,26
COS
0,26
0,26
Operating coil for DC-operation
Standard coil, power consumption at 1,0 Us
Operating range 0,8 ... 1,1 Us
Pick-up PA
W
197
197
197
197
197
2,6
2,6
Holding PH
W
2,6
2,6
2,6
Standard coil, power consumption at 1,0 Us
Switching items at AC-operation
Making delay
ms
9 ... 35
9 ... 35
9 ... 35
9 ... 35
9 ... 35
9 ... 15
9 ... 15
9 ... 15
9 ... 15
Drop-out delay
ms
9 ... 15
Switching items at DC-operation
Standard coil, power consumption at 1,0 Us
Making delay
ms
15 ... 40
15 ... 40
15 ... 40
15 ... 40
15 ... 40
Drop-out delay
ms
9 ... 15
9 ... 15
9 ... 15
9 ... 15
9 ... 15
1) According to VDE 0660 part 102 / IEC 947 -4-1 coordination type permit the following damages: For technical specifications or larger
K contactors through LS450K (1250A),
2 Slight welding of contacts that can easily be opened, is admitted but no further damages.
Short Circuit protection of main contacts1)
Coordination type 2
no welding
Operating coil for AC-operation
Operating range 0,8 ... 1,1 Us Pick-up PAS

request from factory.


51

COMPONENT
CONTROLS

REVERSING STARTERS
and CONTACTORS
Complete line of open type and
enclosed controls
Mini Reversing Contactor
Type RLS7K-

NEMA Type 1

(metal)

NEMA 3R
NEMA 12

(metal)
(metal)

NEMA 4X
X-Proof

(fiberglass)
(contact factory)

3 pole electrical and mechanically


interlocked starters.
UL and NEMA rated contactors
and starters

Applications

Mini Reversing Starter


Type RXLS05
(NEMA SIZE 0)

Gear motors
Milling machines
Overhead garage doors
Presses

Conformity to Standards

REVERSING STARTERS
and CONTACTORS

IEC 947VDE 0660


BS 5424

ELECTRICAL & ELECTRONIC


CONTROLS, INC.
3881 DANBURY ROAD
BREWSTER, NY 10509
845-278-5777 FAX 845-278-5444
E-MAIL: info@eecontrols.com
EE CONTROLS, LTD
17 STEWART COURT
ORANGEVILLE, ONTARIO
CANADA L9W 3Z9
519-941-6845 FAX 519-940-0514
E-Mail: infoeecontrols@on.aibn.com

55

You might also like