You are on page 1of 7

ANSI/ASQC Z1.

4/MIL-STD-105E/BS 6001/DIN 40080/ISO 2859/NF X 06-022

Table.Sample Size Code Letters


Lot or Batch Size

Special Inspection Levels

General Inspection Levels

S-1

S-2

S-3

S-4

II

III

15

16

25

26

50

51

90

91

150

151

280

281

500

501

1200

1201

3200

3201

10000

10001

35000

35001

150000

150001

500000

500001 and Over

Table Single Sampling Plans For Normal Inspection


Acceptable Quality Levels(Normal Inspection)

Sample
Sample
Size Code
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400 650
Size
Letter
Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A

13

20

32

50

80

125

200

315

500

800

1250

2000

0 1
0
0
0
0
0
0
0
0
0
0
0
0
0
0

1
1

1 2

8 10 11 14 15 21 22 30 31 44 45

8 10 11 14 15 21 22 30 31 44 45

2 3

8 10 11 14 15 21 22

3 4

8 10 11 14 15 21 22

5 6

7 8 10 11 14 15 21 22

8 10 11 14 15 21 22

8 10 11 14 15 21 22

8 10 11 14 15 21 22

2 2

8 10 11 14 15 21 22

8 10 11 14 15 21 22

3 3

8 10 11 14 15 21 22

8 10 11 14 15 21 22

6 7

8 10 11 14 15 21 22

8 10 11 14 15 21 22 30 31 44 45

Use first sampling plan below arrow.If sample size equals.or exceeds lot or batch size,do 100 percent inspection.
Use first sampling plan babove arrow.
Ac

Acceptance number

Re

Rejection number.

8 10 11 14 15 21 22 30 31

7 8 10 11 14 15 21 22

4 5

ng Plans For Normal Inspection

e Quality Levels(Normal Inspection)


1000
Ac Re
30 31
44 45

Table Single Sampling Plans For Tightened Inspection


Acceptable Quality Levels(AQL)
Sample
Size Code
Letter

Sample 0.010 0.015 0.025 0.040 0.065 0.10


Size

0.15

0.25

0.40

0.65

1.0

1.5

2.5

4.0

6.5

10

15

25

40

65

100

150

250

400

650

Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A

13

20

32

50

80

125

200

315

500

800

1250

2000

3150

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

1
1

1
1

2 2

1
2

9 12 13 18 19 27 28 41 42

9 12 13 18 19

9 12 13 18 19

9 12 13 18 19

9 12 13 18 19

9 12 13 18 19

6 8

9 12 13 18 19

9 12 13 18 19

2 2

9 12 13 18 19

3 3

9 12 13 18 19

9 12 13 18 19 27 28 41 42

4 5

9 12 13 18 19

9 12 13 18 19 27 28 41 42

9 12 13 18 19

6 8

4 5

3 3

9 12 13 18 19 27 28

Use first sampling plan below arrow.If sample size equals.or exceeds lot or batch size,do 100 percent inspection.
Use first sampling plan babove arrow.
Ac

Acceptance number

Re

Rejection number.

9 12 13 18 19

3 3

2 2

g Plans For Tightened Inspection


Acceptable Quality Levels(AQL)
1000
Ac Re
27 28
41 42

Table Single Sampling Plans For Reduced Inspection


Acceptable Quality Levels(AQL)
Sample
Size Code
Letter

Sample 0.010 0.015 0.025 0.040 0.065 0.10


Size

0.15

0.25

0.40

0.65

1.0

1.5

2.5

4.0

6.5

10

15

25

40

65

100

150

250

400

650

Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac
A

13

20

32

50

80

125

200

315

500

800

0
0

0 1
0
0
0
0
0
0

0
0

0
0

1
1

0 1
0

1
2

9 10 11

1 2

9 10 11

9 10 11

9 10 11

5 6

9 10 11

6 7

8 9 10 11

9 10 11

9 10 11

9 10 11

2 3

3 4

9 10 11

8 9 10 11 14 15 21 22

9 10 11 14 15 21 22

9 10 11

9 10 11 14 15 21

6 7

9 11 12 15 16 22

3 4

4 5

1 2

8 10 11 14 15 21

5 6

3 4

2 3

Use first sampling plan below arrow.If sample size equals.or exceeds lot or batch size,do 100 percent inspection.
Use first sampling plan babove arrow.
Ac

Acceptance number

Re

Rejection number.

ng Plans For Reduced Inspection


Acceptable Quality Levels(AQL)
650

1000

Re Ac Re
22 30 31
23 30 31
22

You might also like