You are on page 1of 2

PROTECTIVE COATINGS

BERGERLAC ALUMINIUM FINISH


Oleoreisnous Aluminium Paint

PRODUCT
DESCRIPTION

A general purpose Aluminium finish based on Oleoresinous varnish.,


Good weather resistance
High heat and light reflecting power
Dry heat resistance up to 150C

DESIGNED USE

Can be used as a finish on timber, metal and masonry surfaces.


Suitable for both interior and exterior use.
Can be applied directly over intact existing conventional system.

PHYSICAL DATA

VOLUME SOLIDS
(based on ASTM D2697)
TYPICAL DRY FILM THICKNESS
WET FILM THICKNESS
THEORETICAL COVERAGE
COLOUR
FINISH

APPLICATION
DETAILS

45 % + 2%
25 microns
55 microns
18 m2/litre @ 25 microns DFT
Alunimium
High Luster

METHOD OF APPLICATION :
This is a suitable method of application:
Tip Size: 0.43 - 0.54 mm (0.017 - 0.021 in)
Pressure: 110 - 150 kg/cm2 (1600 - 2100 psi)
(Max 5% Thinner)
This is also suitable method. Do not apply thick or heavy
coats otherwise wrinkling, running or sagging may occur.
Additional coats may be required to achieve the
recommended film thickness. (Thinner 5% Max)..

AIRLESS SPRAY

BRUSH OR ROLLER

This is the recommended method of application:


Tip Size: 1.8 mm - 2.2 mm (0.071 - 0.087 mm) Pressure: 40
- 50 psi (2.75 - 3.4) Kg/Cm2
Thinner - 20% max

CONVERTIONALSPRAY
DRYING TIME:
Surface

Touch Dry

Hard Dry

Temperature
15C
25C
35C
45C
NO. OF COMPONENTS
Application Conditions

ADDITIONAL
INFORMATION

8 Hrs
5 Hrs
3 Hrs
2 Hrs

24 Hrs
16 Hrs
10 Hrs
8 Hrs

Recoating Interval
Minimum

Maximum

24 Hrs
16 Hrs
12 Hrs
10 Hrs

Indefinite
Indefinite
Indefinite
Indefinite

One
Do not apply this product if the Relative Humidity exceeds
95% or if the substrate temperature is within 3C of the dew
point

Thinner / Cleaning solvent)


Storage Instruction
Flash Point
Packaging

Solvalux 7 - 9
Store in a cool shaded dry area
40C
1 USG 5 USG

Shelf Life

12 months from the date of Manufacture

BERGERLAC ALUMINIUM FINISH


Oleoreisnous Aluminium Paint

SURFACE
PREPARATION

This coating is usually applied over a suitable primer undercoat or build coat. The underlying system
should be sound and un damaged.
Remove all wax, oil and grease by solvent cleaning in accordance with the guidelines given by SSPC-SPI.
Soluble salts, dirt and dust must be removed prior to coating. Dry brushing should be sufficient. A
freshwater wash must follow to remove all soluble salts.
Always ensure the maximum overcoating time for the primer/build coat has not been exceeded prior to
application.
A number of Berger Primers can be adopted depending on contract requirements.
For all general structural steelwork, piping, ducting etc, apply 2 coats of either LUXAPRIME 1400 or
LUXAPRIME 1300. These would normally be applied after fabrication and/or erection.
When blast cleaning is employed, should a holding primer be required, apply one coat of EPILUX 66 to 25
microns.
For galvanized, metal sprayed or aluminium surfaces, pre-treat with one coat of LUXAPRIME 1500
followed by Bergerlac Aluminium finish.
On Timber apply one coat of Bergerprimer synthetic wood primer followed by Bergerlac Aluminium finish.

PRODUCT USE
INSTRUCTIONS

SAFETY
PRECAUTIONS

Avoid contact with the skin and eyes. Wear suitable protective clothing such as overalls, goggles, dust
masks and gloves. Use a barrier cream.
Ensure that there is adequate ventilation in the area where the product is being applied. Do not breathe
vapour or spray.
This product is flammable. Keep away from sources of ignition. Do not smoke. Take precautionary
measures against static discharge. In case of fire blanket flames with foam, carbon dioxide or dry
chemicals
Refer to MSDS for further information.

FIRST AID

DISCLAIMER

The information provided on this data sheet is not intended to be complete and is provided as general advice only. It is the responsibility of the user to
ensure that the product is suitable for the purpose for which he wishes to use it. As we have no control over the treatment of the product, the standard of
surface preparation of the substrate, or other factors affecting the use of this product, we are not responsible for its performance nor would we accept any
liability whatsoever or howsoever arising from the use of this product unless specifically agreed to in writing by us. The information contained in this data
sheet may be modified by us from time to time, and without notice, in the light of our experience and continuous product development.

Nov. 2004 Version 0

Not suitable for immersed conditions.


Should not exceed dry film thickness more than 40 micron per coat
Dry heat resistance up to 150C
May also be applied between 25 and 40 Microns DFT

Eyes: In the event of accidental splashes, flush eyes with water immediately and obtain medical advice
Skin: Wash skin thoroughly with soap and water or approved industrial cleaner.
DO NOT USE solvent or thinners.
Inhalation: Remove to fresh air, loosen collar and keep patient rested. Ingestion: In case of accidental
ingestion, DO NOT INDUCE VOMITING.
Obtain immediate medical attention