Introduction
ThispaperwillfocusonFoodProcessingOvendesignasitrelatestoaircirculationandheat
sources.Ageneraldescriptionofmainheatsourcesandheatconsumptionarepresented.The
conceptofairchanges,importanceofsupplyairuniformity,andfreshairintakeandexhaust
systemsarebrieflydiscussed.Typicalutilityconsumptionandprocessingcostsaredepictedin
graphicalform.
OvenDesignOverview
FeaturescommonlyfoundinALKARovens:
Stainlesssteelinternalstructuresforcorrosionresistance.
Inflatablegasketdoorsforasmoketightseal.
Floorplatewithraised4waytreadpatternforslipresistance.
Modulatingtemperaturecontroloutputsforprocessaccuracy.
Microprocessorbasedcontrolsforrecipestorageandrepeatableprocesses.
Airhandlingunitsfabricatedfromstainlesssteelforcorrosionresistance.
Ovenroofdeckswithraised4waytreadorantisliptape.
Cleaninplacepipingforlimitedaccessductworkareas.
Polyurethanefoaminsulationforinsulatingvalueandpanelrigidity.
Singlemainairblowerfortotalmixingofrecirculatedair.
Freshairintakeandexhaustsystemswithmodulatingdampersforwetbulb(relative
humidity)control.
Rotatingdampersforenhancedairdistribution.
RecirculatedAirStream
Mostcommonequipmentlocationsareontopoftheovencabinetoronthefloorbehindtheoven.
Theequipmentissizedandconfiguredtomatchovensize,spacelimitations,heatsourceand
processrequirements.Rotatingdampersinthesupplyairductworkareusedtovarythesupplyair
velocities.
Figure1ADampercontrollingairtotherightsideoftheovenisopenandtheleftside
damperisclosed.
Figure1BIllustratesairflowintotheovenwhenthedampersareat45orwhenthereisn't
anydampercontrol.
Figure1CIllustratesthechangeinairflowasthedampersreverse.
HorizontalAirflow
Utilizestwofundamentalairhandlingfeatures,singlemainblowerfortotalairmixingandrotating
dampersforalternatingairflowintheproductzone.Horizontalairflowovensaremostbeneficial
whenprocessingproductsthatareloadedonscreensortrays.Theproductzonehaslimitationsof
approximately12feetwideand12feetlong.
MainHeatSources
Gas,steamandelectricityarethemostcommonheatsourcesforovens.
GasSystemGassystemsareeitherdirectheatorindirectheat.Directheatedsystemsfire
thegasburnerflamedirectlyintothereturnairstreamandimpartheattotheairbymixing
withit.Anindirectheatedsystemfiresthegasburnerflameintoaheatexchangedeviceand
theheatisimpartedtothereturnairbyheattransferfromtheheatexchanger.Naturalgas
andliquidpropanearethetwomostcommonlyusedfuelsforthegasburner.
SteamSystemSteamsystemsareindirectheatsystemsandsupplyheattothereturnairby
passingthereturnairstreamthroughsteamcoils.Thesecoilsareusuallyconstructedof
copper,cupronickelorstainlesstubes,andcopperorstainlesssteelfins.
ALKARsteamcoilsnormallyhavestainlesssteeltubesandcopperfins.Coilsconstructedofall
stainlesssteelareavailablebuthavelessheattransfercapacity.Whenusingallstainless
steelcoils,additionalcoilsareaddedtocompensateforthereducedheattransfercapacity.
ElectricSystemElectricsystemsaredirectheatsystemsandsupplyheattothereturnair
streambypassingtheairthroughabankoftubularheaterelements.Finscanbeaddedto
heaterelementstoincreaseheattransfer.Finsallowtheheaterelementstorunatalower
temperaturewhichwouldextendtheirlife,orfinswouldallowthedesignertoselectasmaller
heaterelementwithhigherwattdensity.
ComparisonofHeatSources
HeatTransferEfficiencyandEffectiveness
GasDirect:Highlyefficientandeffective.Thecombustionprocessis97%efficientandall
heatproducedisabsorbedbytherecirculatingairstream.
Steam:Lessefficientthanadirectgassystem.Coilconstructionisamajorfactorinheat
transferrate.Coppergivesthebestheattransfer(highthermalconductivity)andstainless
steelprovideslessheattransfer(lowthermalconductivity).Thenumberoffinsperinchand
thefinmaterialwillalsoaffectheattransfercapability.Tightfinspacingmakescleaning
difficultandcanresultincoilsbeingpluggedwithsmoketars.Toofewfinswillrequirea
deepercoil(morerows)toprovideanadequateamountofsurfaceareaforheattransfer.
ALKARnormallyprovidescoilswith6finsperinch.Asteamcoilwith6finsperinchprovides
6.5timesmoreheattransferthanabaretubecoilofequalsize.Anallstainlesssteelcoilis
approximately70%aseffectiveasacopperfinandtubecoil.
GasIndirect:Lessefficientthanadirectgassystembecauseanairtoairheatexchangeris
required.Dependinguponthetypeofheatexchangerdesignandconstruction,heattransfer
canbereducedsignificantly.Airisalowheattransfermediumandstainlesssteelhaspoor
thermalconductivity.Insomesystems,upto50%oftheheatcouldbewasted.
Electric:Highlyefficient.Allheatgeneratedbytheheaterelementsispickedupbythe
recirculatingairasitpassesthroughthebankofheaterelements.
AirTemperatureRise
Gasdirect:Fastairtemperaturerisebecauseitisanefficientsystemandhasahighheat
sourcetemperature.Also,gasburnersareavailableincertaincapacitiesand,asarule,the
burnerusedwillhaveacapacitylargerthanwhatthedesignactuallyrequires.
Steam:ReducedairtemperaturerisebecauseofheatexchangerBturequirementsandlower
heatsourcetemperature.
Gasindirect:ReducedairtemperaturerisebecauseofheatexchangerdesignandBtu
requirements.Withgooddesigns,temperaturerisecanapproachequivalentratesofsteam
coils.
Electric:Designedwithreducedairtemperaturerisetomaintainabalancebetween
equipmentcostandoperatingcost.
HighTemperatureProcessing
Gasdirect:Canprocessathightemperatures(over225F)becauseoftheheatsource
temperature.
Gasindirect:Canprocessathightemperatures,butlongerprocesstimesarerequired
becauseofheatexchangerheattransfercapacity.
Electric:Canprocessathightemperatures,butwillhavelongerprocesstimesthandirectgas
becauseofreducedheatinput.Heaterelementtemperaturecanbeashighas1500F.
Steam:Typicallycannotbeusedforhightemperatureprocessing.Nominally,themaximum
processtemperatureislimitedtotwothirdsofthesteamtemperature(e.g.if300Fsteamat
72psig,maximumof200Fprocesstemperature).
Note:MaximumoperatingtemperatureforstandarddesignALKARHighTemperatureOvensis
400F.
EffectsonProduct
Gasdirect:Cookingofnoncuredmeatproductssuchasroastbeeforturkeybreastina
directgasfiredovenwillcausediscolorationaroundtheouteredgesoftheproductcross
section.Thisringisusually1/8"to3"thickandcanbepink,redorpurple,basedonproduct
type.Studieshaveshownthattheringiscausedprimarilybynitrogendioxide(NO2)whichis
acombustionbyproductornaturalgas.
Gasindirect:Noaffect.
Steam:Noaffect.
Electric:Noaffect.
EquipmentCosts
Gasdirect:Heatingequipmentcostsarelessfordirectgasthanforothersystems.An
exceptiontothiswouldbesmallovens,3truckorsmaller,whereelectricallyheatedovens
havethelowestequipmentcost.
Steam:Equipmentcostsaremorethandirectgasbecauseofthesteamcoilsandequipment
design(largerfancabinet).
Gasindirect:Equipmentcostsaremorethandirectgasandsteam,primarilybecauseofthe
heatexchangerandequipmentdesign.
Electric:Equipmentcostsaremorethandirectgasbecauseoftheelectricalheaterelements
andcontrolcomponents.Anexceptiontothiswouldbethesmallersizeovens,3truckor
smaller,whereanelectricsystemwouldbelessexpensivethanagasorsteamsystem.
AirFlowDesign
Characteristicsoflowairchangeovens(39airchanges/minute)
Slowerdryingandslowerinternaltemperatureriserates.
Longerprocesstimes.
Typicallythistypeofovenisusedforfermentedsausageproducts(eitherdryorsemidry
types).
Characteristicsofmediumairchangeovens(915airchanges/minute)
Mostcommonairflowrateinprocessovens.
Bestsuitedforthegeneralprocessingratesofmostproducts.
Ovenlendsitselftoacceptableprocesstimeswhileallowingtheprocessortoworkwiththe
product.
Characteristicsofhighairchangeovens(1520airchanges/minute)
Forproductsthatcantoleratefastsurfacedryingand/orrapidinternaltemperaturerise.
Mostcommoninpoultryprocessingandotherproductsthatareconsideredverystable
(example:95%fatfreehams).
Airflowcalculations
AsdefinedbyALKAR,anairchangeistherecirculatedairflowrate(CFM)dividedbytheempty
ovenvolume(cu.ft.).
Figure3AAirFlowCalculations
Recirculatingairvolume
=airvelocity(fpm)xsupplyairarea(ft2)=ft3/minute
Ovenvolume
=lengthxwidthxheight=ft3
Airflowrate
=recirculatingairvolume(cfm)/ovenvolume(ft3)
Recirculatedairvolume=areaofductoutletxvelocityofairattheoutlet.
Ovenvolume=insidewidthofovenxinsidelengthofovenxovenheight.Ovenheightisthe
distancefromthefloortothebottomoftheoverheadductwork.
Airflow=recirculatedairvolume)ovenvolume=airexchangerate.Commonlyexpressed
asairchangesperminute.
Figure3CRecirculatingAirVolume
RecirculatingAirVolume
=airvelocityxsupplyarea
=(5962+2375)fpmx1.308ft2
=10,905cfm
Figure3DAirFlowRate
AirFlowRate
=recirculatingairvolume)oven
volume
=10,905cfm/911ft2
=11.97airchanges/min.
Note:Whendoingairflowcalculationsitisrequiredthatallmeasurementsbeofcompatibleunits
e.g.areaofductoutletinft2,airvelocityinfeetperminuteandovenvolumeinft3.Adetailedset
ofcalculationsisshowninattachedfigures.
Importanceofuniformsupplyair
Airisthemediabywhichdrying,smokingandheatingisaccomplished.
Properhightolowairvelocityratiosarerequiredtomaintainauniformbutturbulentairflow
patternintheproductzone.
Nonuniformairflowwillleadtocolor,shrink,andinternaltemperaturevariations.
Freshairintakeandexhaustsystems
Freshaircanbetakenfrominsideoroutsideoftheprocessroom.
Aircondition,moisturecontent,andtemperaturemaydeterminebestsource.
Draftsinprocessroomdoorwaysusuallyindicateashortageofmakeupair.
MakeupairunitsshouldbesizedforsmokehouserequirementsPLUSanyotherroomor
adjacentroomexhaustfans.
Energycostcomparisonsformakeupairsystemsneedtoaccountforthreevariables:Energy
cost,aircondition(maybeaseasonalfactor),andprocessrequirements.
Effectsontheprocess
Highmoisturecontentinmakeupaircanlimithowdryyoucanrunaprocess.Relative
humidityorwetbulbcontrolatprocesssetpointrequiresthatthemoistureremovalcapacity
ofthefreshairandexhaustsystembeequaltotheamountofmoisturebeinggivenupbythe
product.
Lowdrybulbtemperatureinmakeupaircanincreasethetimerequiredtoachievedrybulb
setpoint.Lowrelativehumidityorwetbulbsettingswillkeepthemakeupairandexhaust
systematmaximumcapacity,whichinturnconsumesmuchenergy.
HeatConsumption
Howmuchheatisusedtocooktheproductandhowmuchisusedelsewhere?Graph1showsthe
differentpercentagesofheatconsumptionintheoven.Thesearecalculatedvaluesbasedupona
generalbonelesshamcycle.Otherproductcycleswouldyielddifferentpercentagesforthese
values.
Fromtheillustration,youcanseethat20%oftheheatisrequiredtoheattheproductfromits
enteringtemperature(45Finternal)toitsfinalinternaltemperature(152F).Moistureevaporation
accountsfor22%basedupona10%shrinkrate.Inordertoremovethemoisturefromtheproduct,
exhaustmustbeprovided,andthiswillresultinfreshairbeingdrawnintotheoven.Forprocesses
usingalowwetbulbsetting,orforhighmoisturelossproduct(suchasbeefjerky),heatingthe
freshaircanaccountforalargerpercentagesincetheexhaustvolumeisincreased.Heatingthe
equipment(i.e.fancabinet,ducts,trucks/trees/cagessheetsteel),accountsfor19%oftheheat
consumption,and4%islostthroughthefancabinet.
Utilityconsumption
Havingseenwheretheheatisusedintheprocess,howmuchheat(orutility)wasrequiredto
processthisproduct?Graph2showstheamountofeachutilityconsumedduringthebonelessham
cyclebasedupon100poundsofproduct.Theyallrequirethesameamountofheat(Btu's).
Heatingcosts
Knowinghowmuchutilitywasconsumedper100poundsofproduct,whatwastheheatingcost?
Graph3showsthecostofprocessingthe100poundsofbonelesshamsbasedontheutilityratesas
shownonthegraph.Electricheathasthehighestprocessingcost,followedbysteamandgasheat
systems.Thegasprocessingcostwasbasedonadirectheatedsystem.
Summary
Ovensandothertypesofprocessequipmenthavemanydesignvariables.Matchingequipment
productioncapacitytotheusersrequirementsandspatiallimitationsarethestartingpointsofmost
projects.Plantservices,suchassteam,gas,electricity,makeupairandrefrigeration,arewoven
intothefinaldesign.Fabrication,installation,startupandoperatortrainingareotherrequirements
thatareimportantinachievingcustomersatisfaction.