You are on page 1of 1

Installation Instructions for Type B, D & E Single Screens

These screens are of one-piece welded construction, and are simply fixed onto a concrete weir/sump
arrangement. They are made of 304 stainless steel (unless specified otherwise) and are acid cleaned
before shipping. Stainless steel expansion bolts, resin anchors, wedge/sleeve anchors, or other
suitable concrete fixings should be used to fix the screen to the weir (these are not supplied). The
fixing holes in the screens are 13mm diameter, suitable for M10 or M12 bolts.
To install, first position the screen on the weir structure this may require lifting gear for the bigger
screens. The order of fixing will then depend on the type of fixing used. If sleeve anchors are used
then holes can be drilled with the frames in place the 13mm fixing holes will allow for a 12mm
masonry bit. Otherwise mark up the concrete, remove the screen and fit the fixings in place.
Ensure that the concrete is of good quality and is fully cured before drilling, and that the holes
are at least 50mm from any surfaces. The concrete should be designed such that the fixings do not
coincide with any reinforcement bar.
All threads must be lightly covered with anti-seize grease stainless steel fittings can weld
themselves together if this is not done.
Finally the gap between the endplates and the concrete can be filled with grout or good quality mastic
to give a watertight seal. Any gaps under the leading edge of the acceleration plate should also be
filled.

Health & Safety


Follow site-specific rules and risk assessments. In addition:

Wear gloves when handling screens, as they may have sharp edges
For all but the smallest screens, use two or more people to lift and position them as
appropriate. Lifting gear may be required for the larger screens.
Wear eye and ear protection when drilling holes in concrete
Read and follow the COSHH sheets for any grease products or sealants used.

For more details, please refer to:

The Personal Protective Equipment (PPE) at Work Regulations 1992


The Manual Handling Operations (MHO) Regulations 1992
The Noise at Work Regulations 1989
The Control of Substances Hazardous to Health Regulations 2002

AQS-DOC024(F) Type B, D & E Single Screen Installation Instructions.doc Issue F, February 2012 Dulas Ltd
T: +44 (0)1654 705000 F: +44 (0)1654 703000 E: hydro@dulas.org.uk www.dulas.org.uk