Professional Documents
Culture Documents
AIC+ Advanced
Interface
Converter
User
Manual
Important User
Information
SLC, SLC 5/01, SLC 5/02, SLC 5/03, SLC 5/04, SLC 5/05, MicroLogix, Data Highway/Data Highway Plus and Encompass
are trademarks; PLC is a registered trademark of Rockwell Automation. Belden is a trademark of Belden, Inc.
Table of Contents
P1
P1
P1
P2
P3
P3
P3
P3
P3
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Device Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Node Address Identification . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
11
12
12
21
21
21
21
22
22
22
22
23
23
23
24
25
25
26
27
27
27
29
ii
Table of Contents
Network Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31
Network Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Point-to-Point Isolator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Components Replaced by the AIC+ . . . . . . . . . . . . . . . . . . . . . .
DH-485 Network with SLC 5/03 and SLC 5/04 Processors
and a PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DH-485 Network with a MicroLogix 1000 Controller . . . . . . . . . .
Typical 3-Node OEM Network . . . . . . . . . . . . . . . . . . . . . . . . . .
Networked Operator Interface Device and MicroLogix Controller .
Networks Using Ganged Converters . . . . . . . . . . . . . . . . . . . .
Extending Network to 2,438 Meters (8,000 Feet) . . . . . . . . . . . .
DF1 Master-Slave Network with Modem . . . . . . . . . . . . . . . . . .
Avoid Incorrect Connections . . . . . . . . . . . . . . . . . . . . . . . . . . .
31
31
32
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
41
Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
41
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A1
Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hardware Handshaking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Auto Transmit Delay (turn around time) Per Baud Rate . . . . . . . . .
Mounting Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A1
A1
A2
A3
33
34
34
35
36
37
38
39
Preface
Read this preface to familiarize yourself with the rest of the manual.
This preface covers the following topics:
who should use this manual
the purpose of this manual
conventions used in this manual
AllenBradley support
Title
Contents
Preface
Product Overview
Network Connections
Troubleshooting
Specifications
Appendix A
Publication 1761-6.4
P2
Related Documentation
The following documents contain additional information concerning
AllenBradley SLC, PLC and MicroLogix products. To obtain
a copy, contact your local AllenBradley office or distributor.
For
Setting up a DH-485 network
DF1 protocol
Document
Number
1747-6.2
1761-6.3
1747-6.2
1770-6.2.2
1770-6.5.16
1761-6.3
1747-6.2
6873
1770-4.1
SD499
A glossary of industrial
automation terms and
abbreviations
AG-7.1
Publication 1761-6.4
P3
AllenBradley Support
Publication 1761-6.4
Chapter
Product Overview
Description
The baud rate selector switch is used to match the baud rate filter of
the AIC+ to the network baud rate. This switch does not change the
network baud rate and is normally left in the AUTO position. In
high noise environments, the baud rate selector switch should be
taken out of the AUTO mode and set to the same baud rate as the
network. See Auto Transmit Delay on page A2 for more
information on baud rates.
Item
Description
Operating Modes
12
Product Overview
Device Compatibility
There is no node
address associated
with the network port
(Port 3).
Publication1761-6.4
Chapter
EMC Directive
This product is tested to meet Council Directive 89/336/EEC
Electromagnetic Compatibility (EMC) and the following standards,
in whole or in part, documented in a technical construction file:
EN 50081-2
EMC Generic Emission Standard, Part 2 Industrial
Environment
EN 50082-2
EMC Generic Immunity Standard, Part 2 Industrial
Environment
This product is intended for use in an industrial environment.
Publication1761-6.4
22
Safety Considerations
Communication Cables
1761-CBL-PM02 (Series C or later)
1761-CBL-HM02 (Series C or later)
1761-CBL-AM00 (Series C or later)
1761-CBL-AP00 (Series C or later)
2707-NC8 (Series B)
2707-NC9 (Series B)
2707-NC10 (Series B)
2707-NC11 (Series B)
1746-RT30 AIC+ Connector
Mounting
Side
View
Installation
1. Mount your DIN rail.
2. Snap the DIN rail latch into the closed position.
latch
Publication1761-6.4
23
DIN
Rail
Side
View
Panel Mounting
Installation
1. Remove the mounting template from page A3 of this document.
2. Secure the template to the mounting surface.
3. Drill holes through the template.
4. Remove the mounting template.
5. Mount the AIC+.
Publication1761-6.4
24
Mounting
Template
Wiring
!
Important:
Bottom
View
24VDC
DC
NEUT
CHS
GND
Important:
Publication1761-6.4
25
Belden
#3106A or
#9842
Belden
#3106A or
#9842
Belden
#3106A or
#9842
Connector
Connector
Connector
Incorrect
6 Termination
5
A
4
B
3 Common
2 Shield
1 Chassis Ground
Drain Wire
to Previous Device
to Successive Device
To this Terminal
Shield/Drain
Non-jacketed
Terminal 2 Shield
Blue
Blue
Terminal 3 (Common)
White/Orange
Terminal 4 (Data B)
Terminal 5 (Data A)
Publication1761-6.4
26
Shield/Drain
Blue/White
White/Orange
To this Terminal
Non-jacketed
Terminal 2 Shield
Terminal 4 (Data B)
Terminal 5 (Data A)
To prevent confusion when installing the communication cable, cut back the white with blue stripe
wire immediately after the the insulation jacket is removed. This wire is not used by DH-485.
End-of-Line Termination
Jumper
Jumper
Publication1761-6.4
27
Reference Drawing
Item
Description
Selection Guide
1747-CP3
1761-CBL-AC00
Cable
Length
Connections
from
1747-CP3
1761-CBL-AC00
3m ((9.8 ft))
45 cm (17.7 in)
to AIC+
port 1
PC COM port
port 1
port 1
port 1
port 1
Publication1761-6.4
28
1761-CBL-AS09
1761-CBL-AS03
Cable
Length
Connections
from
1761-CBL-AS03
1761-CBL-AS09
3m ((9.8 ft))
9.9m (29.5 ft)
to AIC+
SLC 500 Fixed, SLC 5/01, SLC 5/02, and SLC 5/03 processors
port 3
port 3
1761-CBL-HM02
1761-CBL-AM00
Cable
Length
Connections
from
1761-CBL-AM00
45 cm (17.7 in)
2m (6.5 ft)
1761-CBL-HM02
to AIC+
port 2
no
cable
port 2
yes
external
1761-CBL-PM02
Length
Connections
from
1761-CBL-AP00
45 cm ((17.7 in))
2m (6.5 ft)
1761-CBL-PM02
Selection
Switch
S i
Setting
MicroLogix 1000
1761-CBL-AP00
Cable
External
Power
S
l
Supply
Required
to AIC+
External
Power
S
Supply
l
Required
Selection
Switch
S i
Setting
yes
external
port 2
MicroLogix 1000
port 1
port 2
yes
external
port 2
yes
external
PC COM port
port 2
yes
external
not applicable
Length
Connections
from
to AIC+
port 1
Publication1761-6.4
Recommended User
Supplied Components.E
29
Recommended Model
standard AT
radio modem
1761-CBL-AP00 or 1761-CBL-PM02
DB-9 RS-232
Port 1
6 78
DH-485 connector
Port 3
3
4
5
12
Port 1
DB-9 RS-232
Port 2
(1761-CBL-PM02 cable)
chassis ground
cable shield
signal ground
DH-485 data B
DH-485 data A
termination
not applicable
not applicable
not applicable
not applicable
not applicable
Item
Port 3
DH-485 Connector
An 8-pin mini DIN connector is used for making connections to port 2. This connector is not
commercially available. If you are making a cable to connect to port 2, you must configure your
cable to connect to the Allen-Bradley cable shown above.
Publication1761-6.4
Chapter
Network Connections
Network Diagrams.C
Point-to-Point Isolator.D
1761-CBL-AM00 or 1761-CBL-HM02
MicroLogix
1000
AIC+
24V dc
(Not needed in this
configuration since the
MicroLogix 1000 provides
power to the AIC+ via port 2.)
PC
APS
1747-CP3 or 1761-CBL-AC00
Publication1761-6.4
32
Network Connections
Previous DH-485
Network
24V dc power
1747-PIC
Interface
Converter
1747-AIC
1747-AIC
1747-AIC
SLC 5/02 processor
24V dc power
AIC+
1747-AIC
Publication1761-6.4
1747-AIC
Network Connections
33
PC
APS
PC to port 1
or port 2
24V dc power
1761-CBL-AP00
or
1747-CP3
1761-CBL-PM02
or
1761-CBL-AC00
1761-CBL-AP00
or
1761-CBL-PM02
AIC+
AIC+
1747-CP3
or
1761-CBL-AC00
24V dc
(user
supplied)
1747-AIC
1747-AIC
Publication1761-6.4
34
Network Connections
APS
1761-CBL-AM00 or
1761-CBL-HM02
AIC+
PC to port 1
or port 2
connection from
port 1 or port 2
to MicroLogix
1761-CBL-AP00 or
1761-CBL-PM02
1761-CBL-AP00 or
1761-CBL-PM02
AIC+
24V dc
(user supply needed
if using port 1 on AIC+)
24V dc
(user supplied)
1747-CP3 or
1761-CBL-AC00
RJ45 port
AIC+
PC
APS
1761-CBL-AS09 or
1761-CBL-AS03
3-Node Network
(not expandable)
24V dc
(Not needed in this
configuration since the
MicroLogix 1000
provides power to the
AIC+ via port 2.)
1747-CP3 or 1761-CBL-AC00
Publication1761-6.4
Network Connections
35
PC
APS
PC to port 1
or port 2
RS-232 port
NULL modem
adapter
connection from NULL modem
adapter to port 1 or port 2
1761-CBL-AP00 or
1761-CBL-PM02
1761-CBL-AP00 or
1761-CBL-PM02
1747-CP3 or
1761-CBL-AC00
AIC+
AIC+
24V dc
(user supplied)
1747-CP3 or
1761-CBL-AC00
24V dc
(user supplied)
1747-AIC
AIC+
24V dc
(Not needed in this
configuration since
the MicroLogix
1000 provides
power to the AIC+
via port 2.)
1761-CBL-AM00 or
1761-CBL-HM02
MicroLogix 1000
(Series C or higher)
Publication1761-6.4
36
Network Connections
1761-CBL-AM00 or
1761-CBL-HM02
RJ45 port
1761-CBL-AS09 or
1761-CBL-AS03
AIC+
24V dc
(user supplied)
APS
PC
AIC+
24V dc
(user supplied)
1747-CP3 or 1761-CBL-AC00
DH-485
Network
DH-485 Network
with Fixed Controller
SLC 500
fixed controller
24V dc power
RJ45 port
1761-CBL-AM00 or 1761-CBL-HM02
1761-CBL-AS09 or
1761-CBL-AS03
AIC+
DH-485
Network
Publication1761-6.4
PC
AIC+
1747-CP3 or
1761-CBL-AC00
APS
Network Connections
37
DH-485 Network
1,219m (4,000 ft)
maximum
1761-CBL-AM00 or
1761-CBL-HM02
AIC+
24V dc
(user supplied or
from 24V dc terminals
on SLC controller)
AIC+
24V dc
(user supplied or
from 24V dc terminals
on SLC controller)
DH-485 Network
1,219m (4,000 ft)
maximum
DB-9 RS-232 port
mini-DIN 8 RS-232 port
DH-485/DF1 port
Publication1761-6.4
38
Network Connections
DF1
Master
CH0
DF1
Slave
1761-CBL-AP00 or
1761-CBL-PM02
radio modem
or lease line
AIC+
CH0
1761-CBL-AP00 or
1761-CBL-PM02
AIC+
radio modem
or lease line
CH0 to port 1 or port 2
DF1
1761-CBL-AP00
Slave
or 1761-CBL-PM02
1747-CP3
or 1761-CBL-AC00
AIC+
Important:
AIC+
Publication1761-6.4
Network Connections
39
1747-AIC
DH-485
Network
1761-CBL-AS09 or
1761-CBL-AS03
AIC+
1761-CBL-AS09 or
1761-CBL-AS03
1747-AIC
DH-485
Network
Important:
Publication1761-6.4
Chapter
Troubleshooting
Diagnostics
Item
Indicator
TX RS-232
RS 232 9-pin
9 pin (port 1)
RS 232 8-pin
8 pin (port 2)
TX RS-232
TX RS-485
RS 485 (port 3)
PWR Power OK
Condition
flashing
off
flashing
off
flashing
off
on
off
cable
Indicates
transmitting
receiving or idle
transmitting
receiving or idle
transmitting
receiving or idle
power OK
no power to AIC+ or DC
source switch set incorrectly
24V dc power supplied to
AIC+ from device
connected to port 2
24V dc power supplied to
AIC+ from external source
(use 24V dc power from
SLC or user-supplied 24V
dc power supply)
Publication1761-6.4
Appendix
Specifications.I
Physical Specifications
Description
Specification
20.4 28.8V dc
Current Draw
0 120 mA
200 mA maximum inrush current
500V dc
0 to 60 C (32 to 140 F)
Storage Temperature
40 to 85 C (40 to 175 F)
Agency Certification
UL 1604
C-UL C22.2 No. 213
Class I Division 2 Groups A, B, C, D
CE compliant for all applicable directives
Port 3
RS-485
Port 2
mini-DIN 8
RS-232
Port 1
DB-9
RS-232 DTE
Hardware Handshaking.J
To implement hardware handshaking, use cables that support the
following signals.
Signal Definition
Function
RTS active
CTS active
A2
Specifications.I
Protocol
yes
DF1 Master-Slave
no
yes
Any communication coming off of the RS-485 line (port 3) will not drive the handshaking lines on
ports 1 and 2. Devices on ports 1 and 2 can drive the other RS-232 ports handshaking lines and
the RS-485 transmitters.
Baud Rate
Minimum
Delay
Maximum
Delay
Pre-Send
Transmit
Delay
Typical Delay
600
7.3 ms
15.0 ms
10.8 ms
Setting
16 ms
1200
7.3 ms
15.0 ms
10.8 ms
16 ms
2400
5.5 ms
11.2 ms
8.1 ms
12 ms
4800
2.7 ms
5.7 ms
4.0 ms
6 ms
9600
1.3 ms
2.8 ms
2.0 ms
3 ms
14400
0.9 ms
1.9 ms
1.4 ms
2 ms
19200
0.6 ms
1.4 ms
1.0 ms
2 ms
AUTO
0.3 ms
0.7 ms
0.5 ms
The pre-send transmit delay setting is used in your devices (SLC, PLC, etc.) communications
configuration.
Use a pre-send value from above, depending upon the network baud rate being used.
AIC+
Packet to
Network Device
Network
Device
Packet from
Auto Transmit Network Device
Delay
(turn around time)
Auto Transmit Delay is measured from the time the AIC+ transmits
its last mark out of Port 3, until the delay time (from table above)
expires. The AIC+ will not accept Port 3 data during the Auto
Transmit Delay time.
DB-9 RS-232 port
mini-DIN 8 RS-232 port
RS-485 port
Publication 1761-6.4
Specifications.I
A3
Mounting Template.L
52.07 mm
(2.05 in)
118 mm
(4.64 in)
107 mm
(4.20 in)
27.7 mm
(1.09 in)
Publication 1761-6.4
Index
Symbols
**Empty**, 1
A
AllenBradley, P3
contacting for assistance, P3
C
cable selection guide, 27
reference drawing, 27
selection guide, 27
contents of manual, P1
compatibility, , 12
D
device compatibility,, 12
DIN rail mounting,, 22
installation,, 22
removal,, 23
O
operating modes,, 11
P
panel mounting, installation,, 23
E
European Union Directive Compliance
EMC Directive,, 21
Low Voltage Directive,, 21
European Union Directive Compliance,,
21
R
recommended user supplied components,,
29
M
manuals, related, P2
modes, operating,, 11
safety considerations, 22
mounting template, A3
specifications, A1
auto transmit delay,, A1
hardware handshaking, A1
physical specifications, A1
mounting,, 22
DIN rail mounting,, 22
N
network diagrams,, 31
avoid incorrect connections,, 39
components replace by the AIC+, 32
T
troubleshooting, contacting AllenBradley,
P3
I2
Index
troubleshooting,, 41
diagnostics,, 41
W
wiring, 24
Allen-Bradley, a Rockwell Automation Business, has been helping its customers improve productivity and quality for more than 90 years. We design, manufacture and support a broad range
of automation products worldwide. They include logic processors, power and motion control
devices, operator interfaces, sensors and a variety of software. Rockwell is one of the worlds
leading technology companies.
Worldwide representation.
Argentina Australia Austria Bahrain Belgium Brazil Bulgaria Canada Chile China, PRC Colombia Costa Rica Croatia Cyprus Czech Republic Denmark
Ecuador Egypt El Salvador Finland France Germany Greece Guatemala Honduras Hong Kong Hungary Iceland India Indonesia Ireland Israel Italy
Jamaica Japan Jordan Korea Kuwait Lebanon Malaysia Mexico Netherlands New Zealand Norway Pakistan Peru Philippines Poland Portugal
Puerto Rico Qatar Romania RussiaCIS Saudi Arabia Singapore Slovakia Slovenia South Africa, Republic Spain Sweden Switzerland Taiwan Thailand
Turkey United Arab Emirates United Kingdom United States Uruguay Venezuela Yugoslavia
Allen-Bradley Headquarters, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414 382-2000 Fax: (1) 414 382-4444