You are on page 1of 4

A list of ESXCLI storage commands you

cant live without


Posted on February 25, 2014 by Cormac
There are many occasions where the information displayed in the vSphere client is not sufficient
to display all relevant information about a particular storage device, or indeed to troubleshoot
problems related to a storage device. The purpose of this post is to explain some of the most
often used ESXCLI commands that I use when trying to determine storage device information,
and to troubleshoot a particular device.
Which PSA, SATP & PSP?
First things first, lets figure out is the device is managed by VMwares native multipath plugin,
the NMP. Or indeed is it managed by a third-party plugin, such as EMCs PowerPath? I start with
the esxcli storage nmp device list command. This not only confirms that the device is managed
by NMP, but will also display the Storage Array Type Plugin (SATP) for path failover and the
Path Selection Policy (PSP) for load balancing. Here is an example of this command (Im using
the -d option to run it against one device to keep the output to a minimum).
~ # esxcli storage nmp device list -d naa.600601603aa029002cedc7f8b356e311
naa.600601603aa029002cedc7f8b356e311
Device Display Name: DGC Fibre Channel Disk
(naa.600601603aa029002cedc7f8b356e311)
Storage Array Type: VMW_SATP_ALUA_CX
Storage Array Type Device Config: {navireg=on, ipfilter=on}
{implicit_support=on;explicit_support=on; explicit_allow=on;
alua_followover=on;{TPG_id=1,TPG_state=ANO}{TPG_id=2,TPG_state=AO}}
Path Selection Policy: VMW_PSP_RR
Path Selection Policy Device Config: {policy=rr,iops=1000,
bytes=10485760,useANO=0; lastPathIndex=0: NumIOsPending=0,
numBytesPending=0}
Path Selection Policy Device Custom Config:
Working Paths: vmhba2:C0:T3:L100
Is Local SAS Device: false
Is Boot USB Device: false
~ #

Clearly we can see both the SATP and the PSP for the device in this output. There is a lot more
information here as well, especially since this is an ALUA array. You can read more about what
these configuration options mean in this post. This device is using the Round Robin PSP,
VMW_PSP_RR. One interesting fact even now is the support for Round Robin PSP; some arrays
support it and some do not. It is always worth checking the footnotes of the VMware HCL
Storage section to see if a particular array supports Round Robin. Now that we have the NMP,
SATP & PSP, lets look at some other details.
Queue Depth, Adaptive Queuing, Reservations

This next command is very useful for checking a number of things. Primarily, it will tell you
what the device queue depth is set to. But it will also tell you if adaptive queuing has been
configured, and if the device has for a perennially reserved setting, something that is used a lot in
Microsoft Clustering configurations to avoid slow boots.
~ # esxcli storage core device list -d naa.600601603aa029002cedc7f8b356e311
naa.600601603aa029002cedc7f8b356e311
Display Name: DGC Fibre Channel Disk (naa.600601603aa029002cedc7f8b356e311)
Has Settable Display Name: true
Size: 25600
Device Type: Direct-Access
Multipath Plugin: NMP
Devfs Path: /vmfs/devices/disks/naa.600601603aa029002cedc7f8b356e311
Vendor: DGC
Model: VRAID
Revision: 0532
SCSI Level: 4
Is Pseudo: false
Status: on
Is RDM Capable: true
Is Local: false
Is Removable: false
Is SSD: false
Is Offline: false
Is Perennially Reserved: false
Queue Full Sample Size: 0
Queue Full Threshold: 0
Thin Provisioning Status: unknown
Attached Filters: VAAI_FILTER
VAAI Status: supported
Other UIDs: vml.0200640000600601603aa029002cedc7f8b356e311565241494420
Is Local SAS Device: false
Is Boot USB Device: false
No of outstanding IOs with competing worlds: 32

The last line out output is actually the device queue depth. For this device, 32 I/Os can be queued
to the device. The Queue Full Sample Size and the Queue Full threshold both related to Adaptive
Queuing it is not configured on this device since both values are 0. If youd like to know more
about Adaptive Queuing, you can read this article here.
The perennially reserved flag is an interesting one and a relatively recent addition to device
configurations. With applications that place SCSI reservations on devices (such as Microsoft
Cluster), ESXi host reboots would be delayed as it tried to query devices with SCSI reservation
on them. Perennially Reserved is a flag to tell the ESXi hosts not to waste any time trying to
query these devices on boot as there is a likelihood that they are reserved by another host. This
therefore speeds up the boot times of the ESXi hosts running MSCS VMs.
For those of you contemplating VSAN, VMwares new Virtual SAN product, the ability to
identify SSD devices and local vs. remote devices is critical. VSAN required SSD (or PCIe flash
devices) as well as local magnetic disks. This command will help you identify both.

Apart from some vendor specific information and size information, another interesting item is
the VAAI Status. In this case, VAAI (vSphere APIs for Array integration) is shown as supported.
But how can I find out more information about which primitives are supported? This next
command will help with that.
Which VAAI primitives are supported?
~ # esxcli storage core device vaai status get -d
naa.600601603aa029002cedc7f8b356e311
naa.600601603aa029002cedc7f8b356e311
VAAI Plugin Name: VMW_VAAIP_CX
ATS Status: supported
Clone Status: supported
Zero Status: supported
Delete Status: unsupported

This device, as we can clearly see, supports 3 out of the 4 VAAI block primitives. ATS, Atomic
Test & Set, is the replacement for SCSI reservations. Clone is the ability to offload a clone or
migration operation to the array using XCOPY. Zero is the ability to have the array to zero out
blocks using WRITE_SAME. Delete relates to the UNMAP primitive, and is the ability to
reclaim dead space on thin provisioned datastores. In this example, the primitives shows up as
unsupported.
Useful protocol information
For those of you interested in troubleshooting storage issues outside of ESXi, the esxcli storage
san namespace has some very useful commands. In the case of fiber channel you can get
information about which adapters are used for FC, and display the WWNN (nodename) and
WWPN (portname) information, speed and port state as shown here.
~ # esxcli storage san fc list
Adapter: vmhba2
Port ID: 012800
Node Name: 20:00:00:c0:dd:18:77:d1
Port Name: 21:00:00:c0:dd:18:77:d1
Speed: 10 Gbps
Port Type: NPort
Port State: ONLINE
Adapter: vmhba3
Port ID: 000000
Node Name: 20:00:00:c0:dd:18:77:d3
Port Name: 21:00:00:c0:dd:18:77:d3
Speed: 0 Gbps
Port Type: Unknown
Port State: LINK DOWN

So I have one good adapter, and one not so good. I can also display FC event information:
~ # esxcli storage san fc events get
FC Event Log

------------------------------------------------------------2013-09-23 12:18:58.085 [vmhba2] LINK UP


2013-09-23 13:05:35.952 [vmhba2] RSCN received for PID 012c00
2013-09-23 13:29:24.072 [vmhba2] RSCN received for PID 012c00
2013-09-23 13:33:36.249 [vmhba2] RSCN received for PID 012c00

It should be noted that there are a bunch of other useful commands in this name space, not just
for FC adapters. You can also examine FCoE, iSCSI and SAS devices in this namespace and get
equally useful information.
Useful SMART Information
Another very useful command, especially since the introduction of vFRC (vSphere Flash Read
Cache) and the soon to be announced VSAN, which both support SSD, is the ability to examine
the SMART attributes of a disk drive.
~ # esxcli storage core device smart get -d naa.xxxxxx
Parameter
Value Threshold Worst
---------------------------- ----- --------- ----Health Status
OK
N/A
N/A
Media Wearout Indicator
N/A
N/A
N/A
Write Error Count
N/A
N/A
N/A
Read Error Count
114
6
100
Power-on Hours
90
0
90
Power Cycle Count
100
20
100
Reallocated Sector Count
2
36
2
Raw Read Error Rate
114
6
100
Drive Temperature
33
0
53
Driver Rated Max Temperature 67
45
47
Write Sectors TOT Count
200
0
200
Read Sectors TOT Count
N/A
N/A
N/A
Initial Bad Block Count
100
99
10

While there are still some drives that returns certain fields as N/A, I know there is a concerted
effort underway between VMware and its partners to get this working as much as possible. It is
invaluable to be able to see the media wear out Indicator on SSDs, as well as reallocated sector
count and drive temperature.
I hope you find this useful. Hopefully you can see that there are a lot of extremely useful
commands available in the ESXCLI. Do you use others? And if so, why? Let me know.