HASIL PENGAMATAN DAN ANALISIS DATA

Hasil Pengamatan
R

= 1500

C1

= 47

5%

F = 47 106 F

Dioda 1= IN5394
Dioda 2= IN5394
Dioda 3= IN5394
Dioda 4= IN5394
Kegiatan 1.Penyearah setengah gelombang
No.

Tanpa Filter

V pp

V (V )

Vp

V 0 si

Filter
47F

Vm

V osi

Vm
1

|19,0 0,5||9,50 0,50|

|6,00 0,01||9,0 0,5|

|2,65 0,01||2,4 0,2||7,40 0,01|

|36,5 0,5||18,25 0,50||12,00 0,01||17,5 0,5||5,28 0,01||4,6 0,2||7,40 0,01|

Kegiatan 2.Penyearah gelombang penuh


No.

Tanpa Filter

V pp

V (V )

Vp

V 0 si

Filter
47F

Vm

V osi

Vm
1

|19,0 0,5||9,50 0,50|

|6,00 0,01||8,0 0,2|

|36,5 0,5||18,25 0,50||12,00 0,01||17,0 0,2||10,24 0,01||2,40 0,2||15,53 0,01|

Analisis Data
1. Penyearah setengah gelombang
Untuk Vin = 6 Volt
a. Tanpa Filter

V m (teori )=V p V D

9,50 V 0,70 V =8,8 V

V DC =

V m 8,8 V
=
=2,80 V

3,14

V DC ( praktikum)=2,65 V

|4,67 0,01||1,20 0,2||7,29 0,01|

diff =

V DC (teori )V DC ( praktikum )
100
V DC (ratarata )

2,65 V
|2,80V2,72
|100
0,15V
|
100
2,72V |

5,51 %
b. Dengan Filter

V rpp =

Vm
f R1 C 1

8,8V
( 50 hz ) ( 1500 ) ( 47 106 F )

8,8 V
=2,50 Volt
3,52

V rpp ( praktikum)=2,40 V

diff =

V rpp1 (teori )V rpp 1 ( praktikum)


100
V DC (ratarata )
V
|2,50V2,452,40
|100
V
0,1V
|
100
2,45V |

4,08

V DC =V m

V rpp 1
2,50 V
=8,8 V
=7,55 V
2
2

V DC ( praktikum)=7,40 V

diff =

V DC (teori )V DC ( praktikum )
100
V DC (ratarata )

V 7,40V
|7,557,47
|100
V
0,15V
|
100
7,47 V |

2,0
Untuk Vin = 12 Volt
a. Tanpa filter

V m (teori )=V p V D
18,25V 0,70 V =17,55 V
V DC =

V m 18,25 V
=
=5,81V

3,14

V DC ( praktikum)=5,28 V

diff =

V DC (teori )V DC ( praktikum )
100
V DC (ratarata )
5,28 V
|5,81 V5,54
|100
0,53V
|
100
5,54 V |

9,56 %
b. Dengan Filter

V rpp =

Vm
f R1 C 1

17,55V
( 50 hz ) ( 1500 ) ( 47 106 F )

17,55 V
=4,98Volt
3,52

V rpp ( praktikum)=4,60 V

diff =

V rpp ( teori) V rpp ( praktikum )


100
V DC (ratarata )

V 4,60V
|4,984,79
|100
V
0,38 V
|
100
4,79 V |

7,93
V DC =V m

V rpp
4,98 V
=17,55V
=15,06V
2
2

V DC ( praktikum)=15,20 V

diff =

V DC (teori )V DC ( praktikum )
100
V DC (ra tarata )
V 15,20 V
|15,0615,13
|100
V
0,14 V
|
100
15,13 V |

0,92
2. Penyearah Gelombang Penuh
Untuk Vin = 6 Volt
a. Tanpa Filter

V m (teori )=V p 2V D

9,50 V 2 ( 0,70 ) V =8,1 V


V DC =

2 V m 2(8,1)V
=
=5,16 V

3,14

V DC ( praktikum)=4,67 V

diff =

V DC (teori )V DC ( praktikum )
100
V DC (ratarata )
4,67 V
|5,16 V4,91
|100
0,49V
|
100
4,91 V |

9,97 %

b. Dengan Filter

V rpp =

Vm
2 f R1C1

8,1V
2 ( 50 hz )( 1500 ) ( 47 106 F )

8,1 V
=1,15 Volt
7,04

V rpp ( praktikum)=1,20 V

diff =

V rpp ( teori) V rpp ( praktikum )


100
V DC (ratarata )
V 1,20V
|1,151,17
|100
V
0,05V
|
100
1,17 V |

4,27

V DC =V m

V rpp
1,15 V
=8,1V
=7,53 V
2
2

V DC ( praktikum)=7,29 V

diff =

V DC (teori )V DC ( praktikum )
100
V DC (rat arata )
V 7,29V
|7,537,41
|100
V
0,24 V
|
100
7,41V |

3,23
Untuk Vin = 12 Volt
a. Tanpa Filter

V m (teori )=V p 2V D
18,25V 2(0,70) V =16,85 V

V DC =

2 V m 2(16,85)V
=
=10,73 V

3,14

V DC ( praktikum)=10,24 V

diff =

V DC (teori )V DC ( praktikum )
100
V DC (ratarata )
10,24 V
|10,73 V10,48
| 100
0,49V
|
100
10,48 V |

4,67 %
b. Dengan Filter

V rpp =

Vm
2 f R1C1

16,85 V
2 ( 50 hz )( 1500 ) ( 47 106 F )

16,85 V
=2,39 Volt
7,04

V rpp ( praktikum)=2,40 V

diff =

V rpp ( teori) V rpp ( praktikum )


100
V DC (ratarata )
V
|2,39V2,392,40
|100
V
0,01V
|
100
2,39V |

0,41
V DC =V m

V rpp
2,39 V
=16,85V
=15,66 V
2
2

V DC ( praktikum)=15,53 V

diff =

V DC (teori )V DC ( praktikum )
100
V DC (ratarata )
V 15,53V
|15,6615,59
|100
V
0,13V
|
100
15,59 V |

0,83