AQMesh

Technical specification

Parameters measured
Measurement range

Performance

Sensor life
Power options
Communications
Physical

Environmental
Mounting
Measurement period
Server software

NO, NO2, O3, CO, SO2, Pod temperature, atmospheric pressure, relative humidity, particle count,
PM 2.5#0, PM 10#0
Parameter
Units of measurement
Range
3
NO
ppb or g/m
0 to 4,000 ppb
NO2
ppb or g/m3
0 to 4,000 ppb
NOx
ppb or g/m3
0 to 8,000 ppb
3
O3
ppb or g/m
0 to 1,800 ppb
CO
ppb or g/m3
0 to 6,000 ppb
SO2
ppb or g/m3
0 to 10,000 ppb
Pod temperature
C
-20 to 100 C
Pressure
mb
500 to 1500 mb
Humidity
%
0 to 100 %RH
Particle count
Particles/cm3
0.5 30 m
3
PM 2.5
g/m
0 500 g/ m3
3
PM 10
g/m
0 1,000 g/ m3
#1
#2Accuracy (in standard test conditions)
Parameter
Limit of detection
NO
< 5 ppb
5 ppb
NO2
< 10 ppb
5 ppb
CO
< 5 ppb
5 ppb
O3
< 5 ppb
5 ppb
SO2
< 10 ppb
5 ppb
Pod temperature
0.1 C
2 C
Pressure
1mb
5mb
Humidity
1%RH
5 %RH
Up to 2 years
Primary lithium metal batteries#3. Up to 2 years operation (depending on measurement strategy)
Mains power option, External 12V DC power option, Rechargeable NiMH battery and charger option
Raw data sent to remote server via wireless communications Data access contract may be required
Enclosure
Polyurethane moulded or ABS, protection IP65
Approx. size
L170xW220xH250mm (not inc. antenna 180mm)
Weight
<2Kg
Temperature range: -20 to +40 Deg C #4Humidity range: 15 to 85% RH
Various mounting accessories available
Variable, from 1 minute to 1 hour (1 hour set as default)
Web browser based, processing of raw data to give indicative concentration, database storage on secure
server, data access tables, graphs, data download, multi-user access, password controlled

Product designs and specifications are subject to change without prior notice. The user is responsible for determining the suitability of the product.#0 Based on
standardisation of particle shape and density.#1 From sensor manufacturers specification.
#2
Accuracy is what the sensors are capable of producing given stable temperature and humidity. This data was derived from independent lab tests. Standard test
conditions are 20 Deg C and 80% RH and in the absence of interfering gases.
#3 Subject to carrier restrictions on dangerous goods.
#4 Electrochemical sensors and particle sensors carry a 12 month warranty. Exposure to relative humidity in excess of 85% for five or more days as validated by the onboard RH% sensor will void the warranty for electrochemical sensors.