You are on page 1of 98

2016

PRODUCTCATALOG

PRODUCTS,I
NC.

TheCompanywi
t
hConnect
i
ons

LEARNING,ASSISTINGANDPROVIDING POSITIVESOLUTIONS

Table of Contents
Product Specifications ... 4
Dimensional Data Sheet ... 5
A-LOK Guarantee .......... 9
A-LOK Premium (ASTM C-923)...10
A-LOK Premium (ASTM F-2510) ....12
A-LOK STM ....14
X-CEL ..16
Inserta-LOK ....18
Magnetic Mandrel System ...20
A-LOK Field Sleeves ....21
A-LOK Field Sleeve Installation Instructions..22
X-CEL / Z-LOK Pipe Installation Instructions 23
GrandSlam Lube ...24
Water-Stop .26
A-LOK Water-Stop Gasket Installation Guide ..28
Low Draft/Minimum Taper Hole Formers ...29
G3 Boot System .30
Z-LOK Cast-In Boot Connector ...32
Maximum Parallel Pipe Layout for Z-LOK Mandrels....34
Z-LOK STM ...35
Quik-LOK 39
Installing Quik-LOK on a Mandrel....41
Septic Tank Connectors ...42
Raider Septi-Seal ..43
Dura-Plate 100 Manhole Liner System . 45
Water-LOK . 51
Dura-Plate 100 Epoxy Mortar . 53
Butyl-LOK Sealant Systems ... 55
A-LOK Primary Precast Invert System . 59
Tru-Contour Secondary Precast Invert System .. 61

Key-LOK Lifting System ...... 63


Lift Insert Holders ..... 66
Lift Insert Capacity ............ 67
Universal Lift Bar................................................................................................................................................. 68
Concrete Reinforcement Spacers . 69
Hoop Supports .. 71
Bolt Slot Anchors .. 73
Avanti Multigrout ... 75
Flex-LOK Step Inserts . . 83
Magnetic Angle Tape Measure ..................................... ...84
Big boxes, big seals article .....85
Flexible Storm Sewer Connector Introduced in Orlando article ... 86
Dura-Plate 100 Manhole Liner article .......................................... 87
Worlds Largest Flexible Pipe to Manhole Seal article ...... 88
Save Money for Vermont Towns" article .............................89
Civil Engineering article ...92
Big Beaver Rd. sanitary relief sewers installed article ....96
GatorBar FRP Rebar ....98

PRODUCT SPECIFICATIONS 2016


Learning, Assisting and Providing Positive Solutions
COMPRESSION FIT PIPE TO MANHOLE CONNECTORS
ALOK PREMIUM
ALOK XCEL

SIZE/RANGE
8.50"-102.00"
4.25"-102.00"

Omni-directional Deflection
10 Degrees
10 Degrees

ALOK STM
INSERTALOK

8.50"-102.00"
4.25"-16.00"

10 Degrees
7 Degrees

APPLICATIONS
Flexible watertight connector for sanitary or storm.
Performance watertight connector for sanitary, storm and light
industrial demand.
Watertight connector for storm and light industrial demand.
Watertight connector for cored or cast openings in new or in situtype construction.

BOOT TYPE PIPE TO MANHOLE CONNECTORS


ZLOK

1.25"-21.25"

25 Degrees

G-3

3.50"-13.50"

15 Degrees

ZLOK STM/Smooth-Wall
ZLOK STM/Corrugated
QUIKLOK

14.00''-102.00''
14.50''-41.50''
4.00''-13.00''

15 Degrees/Minimum
15 Degrees/Minimum
20 Degrees

Cast-in place watertight connector for sanitary, storm and light


industrial demand.
Expanded-in-place watertight connector for watertight, storm and
sanitary demands with attached take-down clamp.
Cast-in place watertight connector for storm or sanitary systems.
using smooth wall or corrugated pipe.
Cast-in place watertight connector for sanitary, storm and light
industrial demand with attached take-down clamp.

SEPTIC TANK CONNECTORS BOOT STYLE & COMPRESSION


ALOK SEPTIC SEAL
QUIKLOK SEPTIC SEAL

1.5"-4.50"
4.00''-6.00''

7 Degrees
10 Degrees

Compression watertight connector for septic structures.


Cast-in boot style watertight connector for septic structures with
attached take-down clamp.

GROUTED IN CONNECTIONS
WATERSTOP

Designed for NEW or EXISTING stormwater structures to seal cold


joint pipe penetrations, creating a watertight and soil-tight seal
between pipe and connector. Provides a surface for concrete and
grout to adhere. For all smooth-wall or HDPE corrugated pipe.

4.25"-120.00"

CORROSION RESISTANT LINERS


DURA-PLATE 100

SIZE/RANGE
48.00"-144.00"

Minimum Thickness
65 Mils

DURA-PLATE 100 EPOXY MORTAR

GRADE RING SEALS


WATERLOK

SIZE/RANGE
24" and 30"

Extra strong PVC interior protection for round concrete structures from
hydrogen sulfide and other acidic conditions in wastewater, and light
industrial structures.
3 part epoxy resin provides concrete and masonry surfaces with
increased chemical resistance.

Height Adjustment Capabilities


.00"-14''
Telescoping, flexible, watertight gradering protective liner system
for manholes.

SPACERS & REINFORCEMENT ACCESSORIES


Non-Corrosive plastic PyramidLOK spacers and metal spacers for round, arch and elliptical pipe, manholes, box sections, catch basins,
septic tanks and cast-in place products. Hoop Supports to hold single wire reinforcement in place.

KEYLOK LIFT SYSTEM AND UNIVERSAL LIFT BAR


Certified manhole lifting system for wall thickness up to 6.00" and weights up to 6,500 lbs.
Includes: KEYLOK Lift Inserts, Lift Insert Holders, Lift Pins and Lift Bars.

INVERT CHANNELING EQUIPMENT


ALOK PRIMARY SYSTEM
TRU-CONTOUR
SECONDARY SYSTEM

SIZE RANGE
8", 10", 12"
4.00"-48.00"

Increments
7 Degrees
Available in
2 Degree increments

Mono-lithic pour casting equipment for wastewater and storm structures.


Secondary pour casting equipment for wastewater and storm
structures.

ADDITIONAL ALOK PRODUCTS


HOLE FORMERS - METAL & FIBERGLASS
MANDRELS
VERTITE ELASTOMERIC SEALS FOR PIPES
OR MANHOLES
AVANTI GROUT REPAIR SEALANTS

BUTYLLOK SEALANTS
GRANDSLAM LUBE
BOLT SLOT ANCHORS
BONDUIT CONCRETE ADHESIVE
MAGNETIC ANGLE TAPE MEASURE

Visit our website - www.a-lok.com


800-822-2565 215-547-3366 FAX 215-547-5260
P.O. Box 1647 Tullytown, PA 19007 info@a-lok.com

MAGNETIC: STEP INSERT HOLDERS,


MANDRELS, HOLE FORMERS
CAST-IN-PLACE FIELD SLEEVES
SQUARE & ROUND STEP INSERTS
KELLYS CONCRETE DISSOLVER
Copyright 2016 ALOK Products, Inc.

DIMENSIONAL DATA SHEET


ALOK X-CEL, PREMIUM & STM CONNECTOR / EQUIPMENT
ALOK
ALOK
Mandrels
CONNECTOR NOMINAL CONNECTOR
/ MANDREL PIPE OD / MANDREL Round Flat
CROSS
+/- 0.25
NUMBER
I.D.
SECTION

xx92

xx93

*140
*150
*160
*165
*170
185
*200
*210
*225
*235
240
255
*285
*300
*310
*320
325
330
340
*350
355
*370
380
*385
390
400
*410
415
*425
440
455
470
475
480
490
500
520
525
535
540
560
570

4.25
4.50
4.75
5.00
5.25
5.75
6.25
6.50
6.875
7.25
7.50
7.82
8.50
9.00
9.25
9.50
9.75
10.00
10.25
10.50
10.75
11.25
11.50
11.75
12.00
12.25
12.50
12.75
13.00
13.25
14.00
14.25
14.375
14.75
15.25
15.50
16.00
16.25
16.50
16.625
17.00
17.50

3.25
3.50
3.75
4.00
4.25
4.75
5.25
5.50
5.875
6.25
6.50
6.82
7.00
7.50
7.75
8.00
8.25
8.50
8.75
9.00
9.25
9.75
10.00
10.25
10.50
10.75
11.00
11.25
11.50
11.75
12.50
12.75
12.825
13.25
13.75
14.00
14.50
14.75
15.00
15.125
15.50
16.00

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

Field
Sleeves
Round

Flat

X
X
X
X
X

X
X
X
X
X

X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X

X
X

X
X

X
X

X
X

X
X
X

X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

NOTES

IMPORTANT THE TYPE AND OUTSIDE DIAMETER (OD) OF THE PIPE WILL BE REQUIRED WHEN PLACING AN
ORDER FOR CONNECTORS AND EQUIPMENT TO ENSURE PROPER SELECTION. ALL DIMENSIONS SUBJECT
TO MANUFACTURERS TOLERANCE.
MANDREL AND FIELD SLEEVE LISTED WITH X ARE CURRENTLY AVAILABLE FOR STANDARD STRUCTURE
CONFIGURATIONS. ITEMS WITH BLANKS WILL REQUIRE REVIEW BEFORE ORDERING.
WEB: WWW.A-LOK.COM E-MAIL: INFO@A-LOK.COM PHONE 1-800-822-2565
January, 2016 SUPERCEDES ALL PREVIOUS INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE.

DIMENSIONAL DATA SHEET


ALOK X-CEL, PREMIUM & STM CONNECTOR / EQUIPMENT
ALOK
ALOK
Mandrels
CONNECTOR NOMINAL CONNECTOR
/ MANDREL PIPE OD / MANDREL Round Flat
CROSS
+/- 0.25
NUMBER
I.D.
SECTION

xx93

xx94

580
600
610
620
630
635
640
650
660
675
690
700
710
720
740
750
770
780
800
805
815
820
840
850
855
860
870
890
900
915
920
930
970
980
1000
1020
1030
1035
1040
1050
1070
1090

18.00
18.50
18.75
19.125
19.50
19.75
20.00
20.25
20.50
21.00
21.375
21.437
22.00
22.50
23.00
23.50
24.00
24.50
24.75
25.00
25.50
25.75
26.00
26.50
26.75
27.00
27.50
28.00
28.25
28.50
28.75
29.00
30.00
30.50
30.75
31.25
31.50
31.625
32.00
32.375
32.875
33.50

16.50
17.00
17.25
17.625
18.00
18.25
18.50
18.75
19.00
19.50
19.875
19.937
20.50
21.00
21.50
22.00
22.50
23.00
23.25
23.50
24.00
24.25
24.50
25.00
25.25
25.50
26.00
26.50
26.75
27.00
27.25
27.50
28.00
28.50
28.75
29.25
29.50
29.625
30.00
30.375
30.875
31.50:

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X

Field
Sleeves
Round Flat

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X

X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X

X
X
X
X

X
X
X

X
X
X
X
X
X

NOTES

X
X
X
X
X

X
X
X
X
X
X

IMPORTANT THE TYPE AND OUTSIDE DIAMETER (OD) OF THE PIPE WILL BE REQUIRED WHEN PLACING AN
ORDER FOR CONNECTORS AND EQUIPMENT TO ENSURE PROPER SELECTION. ALL DIMENSIONS SUBJECT
TO MANUFACTURERS TOLERANCE.
MANDREL AND FIELD SLEEVE LISTED WITH X ARE CURRENTLY AVAILABLE FOR STANDARD STRUCTURE
CONFIGURATIONS. ITEMS WITH BLANKS WILL REQUIRE REVIEW BEFORE ORDERING.
WEB: WWW.A-LOK.COM E-MAIL: INFO@A-LOK.COM PHONE 1-800-822-2565
January, 2016 SUPERCEDES ALL PREVIOUS INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE.

DIMENSIONAL DATA SHEET


ALOK X-CEL, PREMIUM & STM CONNECTOR / EQUIPMENT
ALOK
ALOK
Mandrels
CONNECTOR NOMINAL CONNECTOR
/ MANDREL PIPE OD / MANDREL Round Flat
CROSS
+/- 0.25
NUMBER
I.D.
SECTION

xx94

1100
1110
1130
1140
1160
1180
1200
1210
1220
1230
1235
1240
1250
1260
1280
1310
1320
1330
1350
1360
1370
1390
1420
1430
1470
1475
1480
1500
1510
1530
1540
1560
1570
1600
1610
1625
1630
1640
1650
1670
1690
1700

33.80
34.25
35.00
35.25
35.75
36.25
37.00
37.50
37.70
38.00
38.375
38.50
38.75
39.00
39.50
40.50
40.75
41.125
42.00
42.25
42.50
43.25
44.00
44.50
45.50
45.75
46.00
46.625
46.90
47.50
48.00
48.375
49.00
49.75
50.00
50.50
50.75
51.00
51.50
52.00
52.50
52.75

31.75
32.25
33.00
33.25
33.75
34.25
35.00
35.50
35.70
36.00
36.375
36.50
36.75
37.00
37.50
38.50
38.75
39.125
40.00
40.25
40.50
41.25
42.00
42.50
43.50
43.75
44.00
44.625
44.90
45.50
46.00
46.375
47.00
47.75
48.00
48.50
48.75
49.00
49.50
50.00
50.50
50.75

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X

Field
Sleeves
Round Flat

X
X
X
X
X
X
X
X

X
X

X
X
X

X
X
X
X

X
X
X
X

X
X
X

X
X
X
X
X

NOTES

X
X
X
X
X

X
X

X
X
X
X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X
X

X
X

X
X

IMPORTANT THE TYPE AND OUTSIDE DIAMETER (OD) OF THE PIPE WILL BE REQUIRED WHEN PLACING AN
ORDER FOR CONNECTORS AND EQUIPMENT TO ENSURE PROPER SELECTION. ALL DIMENSIONS SUBJECT
TO MANUFACTURERS TOLERANCE.
MANDREL AND FIELD SLEEVE LISTED WITH X ARE CURRENTLY AVAILABLE FOR STANDARD STRUCTURE
CONFIGURATIONS. ITEMS WITH BLANKS WILL REQUIRE REVIEW BEFORE ORDERING.
WEB: WWW.A-LOK.COM E-MAIL: INFO@A-LOK.COM PHONE 1-800-822-2565
January 2016 SUPERCEDES ALL PREVIOUS INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE.

DIMENSIONAL DATA SHEET


ALOK X-CEL, PREMIUM & STM CONNECTOR / EQUIPMENT
ALOK
ALOK
Mandrels
CONNECTOR NOMINAL CONNECTOR
/ MANDREL PIPE OD
CROSS
/ MANDREL Round Flat
+/- 0.25
NUMBER
SECTION
I.D.

xx94

xx95

1705
1707
1710
1745
1790
1820
1830
1840
1850
1860
1870
1910
1920
1930
1940
1970
2040
2050
2060
2070
2080
2140
2160
2170
2210
2300
2310
2360
2430
2520
2560
2600
2740
2750
2800
2820
2840

53.00
53.60
54.00
54.50
56.00
56.875
57.00
57.50
57.75
58.00
58.375
59.50
60.00
61.50
62.00
63.00
65.00
65.50
65.75
66.00
66.50
67.00
67.625
68.00
69.375
72.00
72.375
73.50
75.50
79.00
80.50
81.50
86.00
86.25
87.50
88.75
89.25

51.00
51.60
52.00
52.50
54.00
54.875
55.00
55.50
55.75
56.00
56.375
57.50
57.50
59.00
59.50
60.50
62.50
63.00
63.25
63.50
64.00
64.50
65.125
65.50
66.875
69.50
69.875
71.00
73.00
76.50
78.00
79.00
83.50
83.75
85.00
86.25
86.75

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X
X

Field
Sleeves
Round

X
X
X

Flat

X
X

X
X

X
X
X

X
X

X
X
X
X
X
X

NOTES

X
X
X
X
X
X

X
X

X
X

X
X

X
X

X
X

X
X
X

X
X
X

IMPORTANT THE TYPE AND OUTSIDE DIAMETER (OD) OF THE PIPE WILL BE REQUIRED WHEN PLACING AN
ORDER FOR CONNECTORS AND EQUIPMENT TO ENSURE PROPER SELECTION. ALL DIMENSIONS SUBJECT
TO MANUFACTURERS TOLERANCE.
MANDREL AND FIELD SLEEVE LISTED WITH X ARE CURRENTLY AVAILABLE FOR STANDARD STRUCTURE
CONFIGURATIONS. ITEMS WITH BLANKS WILL REQUIRE REVIEW BEFORE ORDERING.
WEB: WWW.A-LOK.COM E-MAIL: INFO@A-LOK.COM PHONE 1-800-822-2565
January, 2016 SUPERCEDES ALL PREVIOUS INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE.

The Company With Connections

TM

THE NEXT LEVEL OF FLEXIBLE CONNECTORS

A-LOK PREMIUM ASTM C-923 APPLICATION


ALOK PREMIUM

Designed to produce a
guaranteed watertight
seal between pipe and
concrete, the ALOK
Premium flexible pipeto-manhole connector
provides maximum
performance on the job
site. Its unique design
not only saves valuable
project time, but also
ensures longevity and
offers unsurpassed
environmental benefits.

KEY ADVANTAGES (Continued)


Precast Concrete
Manhole

Smooth Wall
Pipe

Close-up View
Showing
Connectors
Flexibility

ALOK Premium
Cast in A-LOK Premium Connector.
For all types of smooth wall pipe.
connectors prevent
infiltration and
ex-filtration into wastewater or stormwater systems, and are installed
in the precast structure in a way that does not require coring or
placement after the base component is cast. This eliminates residual
waste from coring, disposal of the slugs or wasted raw material
utilization or energy. Once cast-in, the connector becomes an integral
component of the structure wall.
ALOK Premium has demonstrated in tests that it will meet and
exceed 13 psi of hydrostatic water pressure.

MATERIAL
Extruded from compounds formulated for wastewater applications
and engineered to conform to the requirements of
section 4.1.1 of ASTM C-923, the standard rubber connector is
available in alternative compounds upon request. Contact an ALOK
representative regarding special applications, such as the presence of
hydrocarbons.

KEY ADVANTAGES
The external appearance of the ALOK Premium connector appears to
be a standard connector, but under differential loading or pipe deflection
it will instantaneously react and redistribute its visco-elastic dynamic
core material to maintain its circumferential sealing pressure. This
visco-elasticity behavior is made possible by introducing a blend of
environmentally friendly fibers, binders, polymers and congealing agents
into the connector core which provides a controllable and dynamic
viscose fluid within the connector. In most installations, this material will
remain equally distributed throughout the core of the connector provided
proper pipe bedding practices have taken place. In the event that shortterm or long-term settlement of the pipe begins to occur, the core

material will react by redistributing and equalizing the blended materials


to maintain its proper sealing compression.
A specific combination of fibers and congealing agents have been
selected to prevent the escape or loss of material through absorption or
from minor punctures or tears that could occur during the initial coupling
of the connector and during its service life.
Benefits and advantages include:
1. Functioning on pure compression, the ALOK Premium allows for
fast and easy field installation. After the pipe is beveled and the
connector and pipe are cleaned and lubricated, the pipe is simply
centered in the connector and inserted. Backfilling can be done
immediately, thus enhancing project safety and overcoming the
typical problems of water, running sand and other unstable trench
conditions.
2. Efficient geometry of the profile lowers the coupling force required to
insert the pipe into both radius and flat wall connector designs.
Lower coupling force translates into quicker and easier installation.
3. Increased nominal pipe diameter tolerance over conventional
compression connector designs while still maintaining up to 10
degrees of omnidirectional axial deflection.
4. Dynamic self-sealing core material can compensate for changes in
dimensions and physical eccentricity.
5. Available in a range of sizes from 8 through 48 utilizing existing
ALOK mandrels.
6. Backed by standard A-LOK Watertight Guarantee.
7. Like other ALOK connectors on larger-diameter pipe where size
prohibits a gasket from being installed in a flat plane, the ALOK
Premium can be configured for casting in a curve with the connector
staying perpendicular to the center line of the pipe. Discovered
through years of extensive research and development, this
configuration causes no loss of compression or deflection.

PRODUCT REFERENCES
A.) ASTM C-923
Resilient Connector Between Reinforced Concrete
Manholes Structures, Pipe and Laterals.

B.) ASTM C-1244


Standard Test Method For Concrete Sewer Manholes
by the Negative Air Pressure (Vacuum) Test

C.) ASTM C-478


Standard Specification for Precast Reinforced Concrete
Manhole Sections

PERFORMANCE STANDARD

PRODUCT SPECIFICATIONS

The ALOK Premium connector is guaranteed to meet or exceed all


material and test requirements outlined in ASTM C-923 Resilient
Connectors Between Reinforced Concrete Manhole Structures and
Laterals.
Extruded from compounds formulated for wastewater applications, the
rubber connector is engineered to conform to the requirements of ASTM
C-923. Alternative compounds are available upon special request.

RESILIENT TEST REQUIREMENTS OF A.S.T.M. C-923


TEST

RESULTS

ASTM METHOD

Chemical resistance
1 N Sulfuric acid
1 N Hydrochloric
Acid

no weight loss
no weight loss

at 22C for 48h

Tensile strength

1200 psi or
8.5 MPa, min

D 412

Elongation at break

350% min.

Hardness

5 from mfgs.
specified hardness

D 2240
(Shore A
durometer)

Accelerated
oven-aging

decr. of 15%,
max. of original
tensile strength,
decr. of 20%
max. of elongation

D 573,
701C for
7 days

Compression set

decr. of 25%,
max. of original
deflection

D 395, Method B,
at 70C for 22h

Water absorption

increase of 10%,
max. of original
by weight

D 471, immerse
0.75 by 2-in. or
19 by 25-mm
Specimen in
distilled water
at 70C for 48h

A flexible pipe to manhole connector shall be used whenever a pipe penetrates


into a precast concrete manhole or structure. The connector shall be The ALOK
Premium Connector as manufactured by ALOK Products, Inc., Tullytown, PA or
approved equal.
The design of the connector shall provide a flexible, watertight seal between the
pipe and concrete structure. The connector shall assure that a seal is made
between:
1. The connector and the structure wall by casting the connector integrally with
the structure wall during the manufacturing process in a manner that it will not
pull out during pipe coupling. The connector shall also be capable of being cast
into a round structure by curving the connector in a manner that allows it to
remain centrally located within the structure wall and perpendicular to the pipe.
This configuration will result in no loss of seal or deflection of pipe entering a
concrete structure.
2. The seal between the connector and the pipe shall be made by the
compression of the connector between the outside circumference of the factory
installed smooth oversleeve of a corrugated pipe or the smooth surface of a
traditional pipe and the interior hole opening of the structure. The connector shall
be the only component to affect the seal between the pipe and structure.

Ozone resistance

rating 0

D 1171

Low-temp
brittle point

no fracture at
-40C

D 746

Tear resistance

200 lbf/in.
or 34 kn/m

D 624, Method B

The connector shall be made from materials that conform to the physical and
Section 4, Materials and Manufacture of ASTM C-923 Standard Specification
for Resilient Connectors Between Reinforced Concrete Manhole Structures and
Laterals, and the overall design will meet or exceed Section 7, Test Methods and
Requirements of ASTM C-923. This connector shall be sized specifically for the
type of pipe being used and shall be installed in accordance with the
recommendations of the manufacturer.

IN THE FIELD PIPE


INSTALLATION INSTRUCTIONS
STEP 1:
Confirm that the pipe surface is smooth, clean
and free of foreign materials, chips, gouges and
form seams due to manufacturing or handling.
Slightly bevel any sharp or blunt edges caused by
the cutting of the pipe.
STEP 2:
Lubricate the connector and the entire section
of the pipe that will be inserted into the
connector. The chart below lists A-LOKs
minimum lubrication length L.

Copyright ASTM INTERNATIONAL. Reprinted with permission

PIPE SIZE
8 - 15
16 - 18
21 & Larger

DIMENSIONAL DATA

STEP 3:
Center the pipe and connector square to each other
and insert the pipe into the connector using a
bar or back hoe depending on the size. Once
the pipe is coupled with the connector, deflect the
structure or pipe to achieve the proper angle.

Maximum Pipe O.D. Based on Manhole


Diameter and Pipe Angles Using
ALOK Premium Connectors.

WARNING
To ensure the A-LOK Premium Connector
remains a flexible watertight connector, it is ALOK Products, Inc. strong recommendation that
no mortar be placed between the pipe and wall
of the concrete structure. The use of mortar in this
area would decrease the effectiveness of the
connector to compensate for shear caused by
settlement or ground movement.

MAX. PIPE SIZE ODs

Min. distance between pipes is


approx. 1/2 the smallest pipe OD

Manhole
Diameter
42
48
60
72
84
96
108
120

2016 A-LOK Products, Inc. Supercedes all previous literature

COVERED BY ISSUED AND/OR PENDING PATENTS

135 - 225
Pipe Angle
26.5
31.5
42.0
52.5
59.5
73.5
76.0
85.0

MIN. LUBRICATION LENGTH L


12
18
24

90
Pipe Angle
22.0
25.0
32.0
38.0
44.0
50.0
56.0
62.0

CAUTION:

When installing pipe stubs


for future pipeline installation,
all stubs must be properly
restrained to prevent any
movement by means other
than the A-LOK
PremiumConnector.

NOTE:
To find approximate subgrade, measure from the
outside base of the structure to the junction of the
connector and flat spot. Then add the wall
thickness of the pipe plus 1/4 inch.

P.O. BOX 1647 697 MAIN STREET TULLYTOWN, PA 19007 info@a-lok.com


800-822-2565 215-547-3366 215-547-5260 FAX www.a-lok.com

The Company With Connections

TM

THE NEXT LEVEL OF FLEXIBLE CONNECTORS

A-LOK PREMIUM ASTM F-2510 APPLICATION


ALOK PREMIUM

The ALOK Premium


Precast Concrete
Manhole
is a flexible compression
Smooth
connector designed to be
Oversleeve
integrated into a
watertight system based
on ASTM F-2510. When
used with a corrugated
Close-up View
HDPE
pipe with a factory
Showing
Corrugated Pipe
Connectors
installed smooth
Installed in
Flexibility
Connector
oversleeve or with a
smooth wall pipe, the
ALOK Premium will
provide a guaranteed
watertight seal between
Smooth
the pipe and the wall of a
Oversleeve
concrete structure. Its
A-LOK Premium Connector making a
unique design not only
watertight connection with HDPE
Corrugated Pipe using a factory installed
provides maximum
smooth oversleeve.
performance but saves
valuable project time, extends the longevity of the structures and
reduces the projects overall environmental impact.

ALOK Premium connectors prevent infiltration and ex-filtration about


the pipe interface in wastewater or stormwater systems. They are
installed in the structure in a way that does not require coring or
placement as a secondary operation. This eliminates residual waste from
coring, the disposal of the slugs, inefficient raw material utilization and
excess energy use. Once cast-in, the connector becomes an integral
component of the structures wall.

MATERIAL
The connectors are extruded from rubber compounds that are formulated
for wastewater applications and engineered to conform to the
requirements of ASTM F-2510. The ALOK Premium connector is
also available in alternative rubber compounds upon request. Please
contact an ALOK representative regarding additional benefits and
special applications, such as the presence of hydrocarbons.

DEFLECTION PERFORMANCE
Axial Deflection of Pipe (Angular) - 10 degrees
Outside Diameter of Pipe Deflection from Loading: 5% in accordance to
ASTM F-2510

KEY ADVANTAGES
The external appearance of the ALOK Premium connectors appear to
be a standard connector, but under differential loading or pipe deflection
it will instantaneously react and redistribute its visco-elastic dynamic
core material to maintain its circumferential sealing pressure. This
visco-elasticity behavior is made possible by introducing a blend of
environmentally friendly fibers, binders, polymers and congealing agents
into the connector core which provides a controllable and dynamic
viscose fluid within the connector. In most installations, this material will

KEY ADVANTAGES (Continued)


remain equally distributed throughout the core of the connector provided
proper pipe bedding practices have taken place. In the event that shortterm or long-term deflection of the pipe begins to occur, the core material
will react by redistributing and equalizing the blended materials to
maintain its proper sealing compression.
A specific combination of fibers and congealing agents have been
selected to prevent the escape or loss of material through absorption or
from minor punctures or tears that could occur during the initial coupling
of the connector and during its service life.
ALOK Premium has successfully been tested to ASTM F-2510
deflection requirements of 5% without loss of seal.
Benefits and advantages include:
1. Functioning on pure compression, the ALOK Premium allows for
fast and easy field installation. After the pipe is beveled and the
connector and pipe are cleaned and lubricated, the pipe is simply
centered in the connector and inserted. Backfilling can be done
immediately, thus enhancing project safety and overcoming the
typical problems of water, running sand and other unstable trench
conditions.
2. Efficient geometry of the profile lowers the coupling force required to
insert the pipe into both radius and flat wall connector designs.
Lower coupling force translates into quicker and easier installation.
3. Increased nominal pipe diameter tolerance over conventional
compression connector designs while still maintaining up to 10
degrees of omnidirectional axial deflection.
4. Connector can meet the 5% deflection requirements of ASTM F2510 without loss of seal or compression. Dynamic self-sealing
core material can compensate for changes in dimensions and
physical eccentricity.
5. Available in a range of sizes from 8 through 48 utilizing existing
ALOK mandrels.
6. Backed by standard A-LOK Watertight Guarantee.
7. Like other ALOK connectors on larger-diameter pipe where size
prohibits a gasket from being installed in a flat plane, the ALOK
Premium can be configured for casting in a curve with the connector
staying perpendicular to the center line of the pipe. Discovered
through years of extensive research and development, this
configuration causes no loss of compression or deflection.

PRODUCT REFERENCES
A.) ASTM F-2510 Standard Specification for Resilient
Connectors Between Reinforced Concrete Manhole
Structures and corrugated High Density Polyethylene Pipes.
B.) ASTM C-478 Standard Specification for Precast
Reinforced Concrete Manhole Sections.
C.) ASTM C-913 Standard Specification for Precast Concrete
Water and Wastewater Structures.

PERFORMANCE STANDARD

PRODUCT SPECIFICATIONS

The ALOK Premium connector is guaranteed to meet or exceeds all


material and test requirements outlined in ASTM F-2510 Resilient
Connectors Between Reinforced Concrete Manhole Structures and
Corrugated High Density Polyethylene Drainage Pipes.
Extruded from compounds formulated for wastewater applications, the
rubber connector is engineered to conform to the requirements of ASTM
F-2510. Alternative compounds are available upon special request.

RESILIENT TEST REQUIREMENTS OF A.S.T.M. F-2510


TEST

RESULTS

Original Properties
Tensile strength,
min, psi (MPa)

1200 psi (8.3)

Elongation
min, %

325

Hardness
Type A durometer

40 to 60

Low-temperature hardness,
Type A durometer, max increase, points

15

Compression set, max %

25

Ozone resistance

No cracks

Low Temperature Brittle Point

No Fractures -40F
(-40C)

Tear Resistance
lbf/in (kN/m), Die B

A flexible pipe to manhole connector shall be used whenever a pipe penetrates


into a precast concrete manhole or structure. The connector shall be The ALOK
Premium Connector as manufactured by ALOK Products, Inc., Tullytown, PA or
approved equal.
The design of the connector shall provide a flexible, watertight seal between the
pipe and concrete structure. The connector shall assure that a seal is made
between:
1. The connector and the structure wall by casting the connector integrally with
the structure wall during the manufacturing process in a manner that it will not
pull out during pipe coupling. The connector shall also be capable of being cast
into a round structure by curving the connector in a manner that allows it to
remain centrally located within the structure wall and perpendicular to the pipe.
This configuration will result in no loss of seal or deflection of pipe entering a
concrete structure.
2. The seal between the connector and the pipe shall be made by the
compression of the connector between the outside circumference of the factory
installed smooth oversleeve of a corrugated pipe or the smooth surface of a
traditional pipe and the interior hole opening of the structure. The connector shall
be the only component to affect the seal between the pipe and structure.
The connector shall be made from materials that conform to the physical and
Section 4, Materials and Manufacture of ASTM F-2510 Standard Specification
for Resilient Connectors Between Reinforced Concrete Manhole Structures and
Corrugated High Density Polyethylene Drainage Pipes, and the overall design will
meet or exceed Section 7, Test Methods and Requirements of ASTM F-2510.
This connector shall be sized specifically for the type of pipe being used and shall
be installed in accordance with the recommendations of the manufacturer.

200 (34)

Accelerated Aging (Air Oven Test):


Decrease in tensile strength,
max % of original

15

Decrease in elongation,
max % of original

20

Hardness, Type A durometer,


max increase, points

INSTALLATION INSTRUCTIONS
STEP 1:
Confirm that the pipe surface is smooth, clean
and free of foreign materials, chips, gouges and
form seams due to manufacturing or handling.
Slightly bevel any sharp or blunt edges caused by
the cutting of the pipe.

After Water Immersion:


Change in volume max %

STEP 2:
Lubricate the connector and the entire section
of the pipe that will be inserted into the
connector. The chart below lists A-LOKs
minimum lubrication length L.

Copyright ASTM INTERNATIONAL. Reprinted with permission

PIPE SIZE
8 - 15
16 - 18
21 & Larger

DIMENSIONAL DATA

STEP 3:
Center the pipe and connector square to each other
and insert the pipe into the connector using a
bar or back hoe depending on the size. Once
the pipe is coupled with the connector, deflect the
structure or pipe to achieve the proper angle.

Maximum Pipe O.D. Based on Manhole


Diameter and Pipe Angles Using
ALOK Premium Connectors.

WARNING
To ensure the A-LOK Premium Connector
remains a flexible watertight connector, it is ALOK Products, Inc. strong recommendation that
no mortar be placed between the pipe and wall
of the concrete structure. The use of mortar in this
area would decrease the effectiveness of the
connector to compensate for shear caused by
settlement or ground movement.

MAX. PIPE SIZE ODs

Min. distance between pipes is


approx. 1/2 the smallest pipe OD

Manhole
Diameter
42
48
60
72
84
96
108
120

2009 A-LOK Products, Inc. Supercedes all previous literature

COVERED BY ISSUED AND/OR PENDING PATENTS

135 - 225
Pipe Angle
26.5
31.5
42.0
52.5
59.5
73.5
76.0
85.0

MIN. LUBRICATION LENGTH L


12
18
24

90
Pipe Angle
22.0
25.0
32.0
38.0
44.0
50.0
56.0
62.0

CAUTION:

When installing pipe stubs


for future pipeline installation,
all stubs must be properly
restrained to prevent any
movement by means other
than the A-LOK
PremiumConnector.

NOTE:
To find approximate subgrade, measure from the
outside base of the structure to the junction of the
connector and flat spot. Then add the wall
thickness of the pipe plus 1/4 inch.

P.O. BOX 1647 697 MAIN STREET TULLYTOWN, PA 19007 info@a-lok.com


800-822-2565 215-547-3366 215-547-5260 FAX www.a-lok.com

The Company With Connections

TM

PIPE TO STRUCTURE CONNECTOR FOR STORMWATER SYSTEMS

ALOK STM
ALOK STM

PRODUCT REFERENCES
A.) ASTM C-1478

The ALOK STM is a


flexible pipe-to-manhole connector
designed for the prevention of soil and
water infiltration into
stormwater sewer
systems. It can be
used with both round
and elliptical shaped
pipes and curved and
flat wall structures. It
is available for 8"
diameter and larger
pipes.

MATERIAL
The standard connector is extruded from a polyisoprene compound
engineered to conform with the requirements outlined in section
4.1.1 of ASTM C-1478 Standard Specification for Storm Drain
Resilient Connectors Between Reinforced Concrete Storm Sewer
Structures, Pipes, and Laterals. Alternative compounds are available for unusual applications upon special order.

Standard Specification for Storm Drain Resilient Connectors


Between Reinforced Concrete Storm Sewer Structures, Pipes,
and Laterals.

B.) ASTM C-1244


Standard Test Method For Concrete Sewer Manholes
by the Negative Air Pressure (Vacuum) Test

C.) ASTM C-478


Standard Specification for Precast Reinforced Concrete
Manhole Sections

PERFORMANCE STANDARD
The ALOK STM meets or exceeds all material and test requirements
of ASTM C-1478: Standard Specification for Storm Drain
Resilient Connectors Between Reinforced Concrete Storm Sewer
Structures, Pipes, and Laterals.
See following chart:

RESILIENT MATERIAL TEST OF ASTM C-1478


TEST

KEY ADVANTAGES
The ALOK STM Connector functions on pure compression, making
field installation quick and easy. Just clean and lubricate the connector
and pipe, center the pipe in the connector, and insert. This rapid installation permits immediate backfilling, enhancing project safety and overcomes the normal problems encountered with water, running sand and
other unstable trench conditions. This results in shorter job projections,
while mininizing traffic interruption and cost overruns.
The ALOK STM provides up to 10 of omnidirectional deflection while
still maintaining a watertight seal. This design allows the connector to
compensate for shear due to settlement or ground movement preventing
water and soil infiltration into the sewer system. This proper pipe-tostructure connection minimizes the chance of pothole formation and
sediment build-up in the storm system, saving states and municipalities
money over the life of the structure.
On larger diameter pipe when size prohibits a gasket from being installed
in a flat plane, an ALOK STM Connector can be configured for casting
in a curve with the connector staying perpendicular to the center line of
the pipe. This design has resulted from years of extensive research and
development and causes no loss of compression or deflection.

Chemical resistance
1 N Sulfuric acid
1 N Hydrochloric
Acid
Tensile strength

RESULTS
no weight loss
no weight loss
1200 psi or
8.5 MPa, min

ASTM METHOD
D 543
at 22C for 48h
D 412

Elongation at break

350% min.

Hardness

5 from mfgs.
specified hardness

D 2240
(Shore A
durometer)

Accelerated
oven-aging

decr. of 15%,
max. of original
tensile strength,
decr. of 20%
max. of elongation

D 573,
701C for
7 days

Compression set

decr. of 25%,
max. of original
deflection

D 395, Method B,
at 70C for 22h

Water absorption

increase of 10%,
max. of original
by weight

D 471, immerse
0.75 by 2-in. or
19 by 25-mm
Specimen in
distilled water
at 70C for 48h

Ozone resistance

rating 0

D 1171

Low-temp
brittle point

no fracture at
-40C

D 746

Tear resistance

200 lbf/in.
or 34 kn/m

D 624, Method B

Copyright ASTM INTERNATIONAL. Reprinted with permission

PART 6 DIMENSIONAL DATA


ALOK STM Cross Section /
Pipe Size ODs
93 Series
8.50" - 29.00"

MAX. PIPE SIZE ODs

94 Series
30.00" - 59.50"

Manhole
Diameter
42
48
60
72
84
96
108
120

95 Series
60.00" - 87.50"

Larger Sizes Available


Upon Special Request

INSTALLATION INSTRUCTIONS
STEP 1:
Confirm that the pipe surface is smooth, clean
and free of foreign materials, chips, gouges and
form seams due to manufacturing or handling.
Slightly bevel any sharp or blunt edges caused by
the cutting of the pipe.
STEP 2:
Lubricate the connector and the entire section
of the pipe that will be inserted into the connector. The chart below lists A-LOKs minimum
lubrication length L.
PIPE SIZE
4 - 15
16 - 18
21 & Larger

MIN. LUBRICATION LENGTH L


12
18
24

STEP 3:
Center the pipe and connector square to each other
and insert the pipe into the connector using a
bar or back hoe depending on the size. Once
the pipe is coupled with the connector, deflect the
structure or pipe to achieve the proper angle.
WARNING
To ensure the A-LOK STM Connector remains a
flexible watertight connector, it is A-LOK
Products, Inc. strong recommendation that no
mortar be placed between the pipe and wall of
the concrete structure. The use of mortar in this
area would decrease the effectiveness of the connector to compensate for shear caused by settlement or ground movement.

CAUTION:
When installing pipe
stubs for future pipeline
installation, all stubs
must be properly
restrained to prevent any
movement by means
other than the A-LOK
STM Connector.

NOTE:
To find approximate subgrade, measure from the
outside base of the structure to the junction of the
connector and flat spot. Then add the wall thickness of the pipe plus 1/4 inch.

135 - 225
Pipe Angle
26.5
31.5
42.0
52.5
59.5
73.5
76.0
85.0

90
Pipe Angle
22.0
25.0
32.0
38.0
44.0
50.0
56.0
62.0

MAX. PIPE SIZE ODs


BOX STRUCTURES
Inside Wall
Dimension
2'
3'
4'
5'
6'
7'
8'
9'

Straight
Through
19.50
32.00
44.00
56.00
67.00
80.50
91.25
103.25

90
Pipe Angle
17.50
30.00
42.00
54.00
65.00
78.50
89.25
101.25

PRODUCT SPECIFICATIONS
A flexible pipe to manhole connector shall be used whenever a pipe
penetrates into a precast concrete manhole or structure used in a stormwater
drainage system.
The connector shall be the ALOK STM CONNECTOR as manufactured by
ALOK PRODUCTS, INC., Tullytown, PA, or approved equal.
The design of the connector shall provide a flexible, watertight seal between the pipe
and concrete structure. The connector shall assure that a seal is made between:
(1) The connector and the structure wall by casting the connector
integrally with the structure wall during the manufacturing process in a manner
that it will not pull out during pipe coupling. The connector shall also be capable
of being cast into a round structure by curving the connector in a manner that
allows it to remain centrally located within the structure wall and perpendicular
to the pipe. This configuration will result in no loss of seal or deflection of pipe
entering a concrete structure.
(2) The seal between the connector and the pipe shall be made by the compression of the connector between the outside circumference of the pipe and the interior hole opening of the structure. The connector shall be the only component to
affect the seal between the pipe and structure.
The connector shall be made from materials that conform to the physical and
chemical requirements outlined in Section 4, Materials and Manufacture of
ASTM C-1478 Standard Specification for Storm Drain Resilient Connectors
Between Reinforced Concrete Storm Sewer Structures, Pipes, and Laterals, and
the overall design will meet or exceed Section 7, Test Methods and
Requirements of ASTM C-1478.
The connector shall be sized specifically for the type of pipe being used and shall
be installed in accordance with the recommendations of the manufacturer.

ANY QUESTIONS REGARDING ALOK STM CONNECTOR


INSTALLATION, PLEASE CALL 1-800-822-2565

ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com
800-822-2565 215-547-3366 215-547-5260 FAX

The Company With Connections

TM

INCOMPARABLE PIPE-TO-MANHOLE CONNECTORS FOR SANITARY SYSTEMS

X-CEL
ALOK X-CEL
Designed to produce a
guaranteed watertight
seal between pipe and
concrete, the ALOK
X-CEL flexible pipe-tomanhole connector
provides maximum
performance on the job
site. Its unique design
not only saves valuable
project time, but also
ensures longevity and
offers unsurpassed
environmental benefits.
ALOK X-CEL connectors prevent infiltration and ex-filtration into
wastewater or stormwater systems, and are installed in the precast
structure in a way that does not require coring or placement after the
base component is cast. This eliminates residual waste from coring,
disposal of the slugs or wasted raw material utilization or energy.
Once cast-in, the connector becomes an integral component of the
structure wall.
Based on the traditional ALOK connector, the X-CEL's enhanced
features improve performance. Take the patented water pocket for
example, which utilizes the untapped pressure of ground water to
exert a clamping force around the connector and pipe, allowing the
connector to perform in deeper installations.
Demonstrated in tests higher than 15 psi of hydrostatic water pressure, the X-CEL's unique design provides 45 percent more rubber
contact with the pipe, allowing for greater pipe deflection.

MATERIAL
Molded or extruded from compounds formulated for wastewater
applications and engineered to conform to the requirements of
section 4.1.1 of ASTM C-923, the standard rubber connector is available
in alternative compounds upon request. Contact an ALOK representative regarding special applications, such as the presence of hydrocarbons.

KEY ADVANTAGES
The ALOK X-CEL offers distinct advantages for engineers, specifiers,
precasters and municipalities. An enhanced profile gives the connector
45% greater rubber contact with the pipe, thus allowing the pipe to be
deflected in excess of 10 degrees of omnidirectional deflection, all the
while maintaining a watertight seal. These enhancements allow for
more flexibility to compensate for pipe shear due to settlement or
ground movement.

KEY ADVANTAGES (continued)


On larger-diameter pipe, where size prohibits a gasket from being
installed in a flat plane, the X-CEL can be configured for casting in a
curve with the connector staying perpendicular to the center line of the
pipe. Discovered through years of extensive research and development,
the configurations cause no loss of compression or deflection.
Functioning on pure compression, the X-CEL allows for fast and
easy field installation. After the connector and pipe are cleaned and
lubricated, the pipe is simply centered in the connector and inserted.
Backfilling can be done immediately, thus enhancing project safety and
overcoming the typical problems of water, running sand and other
unstable trench conditions.
For Specifiers, the X-CEL connector offers a guaranteed solution to the
age-old containment system problem of the best way to connect pipes
and concrete structures. Precasters using X-CEL connectors experience
increased satisfaction due to their ability to offer a complete watertight,
guaranteed product, while municipalities that install X-CEL will
ultimately spend less on road repair by avoiding the possibility of pot/sink
holes that are often the result of leaking, non-connected, systems.

PRODUCT REFERENCES
A.) ASTM C-923
Resilient Connector Between Reinforced Concrete
Manholes Structures, Pipe and Laterals.

B.) ASTM C-1244


Standard Test Method For Concrete Sewer Manholes
by the Negative Air Pressure (Vacuum) Test

C.) ASTM C-478


Standard Specification for Precast Reinforced Concrete
Manhole Sections

PERFORMANCE STANDARD
The ALOK X-CEL guaranteed Connector meets or exceeds all
material and test requirements outlined in ASTM C-923: Resilient
Connectors Between Reinforced Concrete Manhole Structures,
Pipes and Laterals.
Molded or extruded from compounds formulated for wastewater
applications, the standard rubber connector is engineered to confirm
with the requirements of section 4.1.1 of ASTM C-923. Alternative
compounds are available upon special request.

PERFORMANCE STANDARD (continued)


RESILIENT TEST REQUIREMENTS OF A.S.T.M. C-923
TEST

RESULTS

ASTM METHOD

Chemical resistance
1 N Sulfuric acid
1 N Hydrochloric
Acid

no weight loss
no weight loss

at 22C for 48h

Tensile strength

1200 psi or
8.5 MPa, min

D 412

Elongation at break

350% min.

Hardness

5 from mfgs.
specified hardness

D 2240
(Shore A
durometer)

Accelerated
oven-aging

decr. of 15%,
max. of original
tensile strength,
decr. of 20%
max. of elongation

D 573,
701C for
7 days

Compression set

decr. of 25%,
max. of original
deflection

D 395, Method B,
at 70C for 22h

Water absorption

increase of 10%,
max. of original
by weight

D 471, immerse
0.75 by 2-in. or
19 by 25-mm
Specimen in
distilled water
at 70C for 48h

Ozone resistance

rating 0

D 1171

Low-temp
brittle point

no fracture at
-40C

D 746

Tear resistance

200 lbf/in.
or 34 kn/m

D 624, Method B

PRODUCT SPECIFICATIONS
A flexible pipe to manhole connector shall be used whenever a pipe
penetrates into a precast concrete manhole or structure. The connector shall be
the ALOK X-CEL CONNECTOR as manufactured by ALOK PRODUCTS, INC.,
Tullytown, PA, or approved equal.
The design of the connector shall provide a flexible, watertight seal between the pipe
and concrete structure. The connector shall assure that a seal is made between:
(1) The connector and the structure wall by casting the connector
integrally with the structure wall during the manufacturing process in a manner
that it will not pull out during pipe coupling. The connector shall also be capable
of being cast into a round structure by curving the connector in a manner that
allows it to remain centrally located within the structure wall and perpendicular
to the pipe. This configuration will result in no loss of seal or deflection of pipe
entering a concrete structure.
(2) The seal between the connector and the pipe shall be made by the compression of the connector between the outside circumference of the pipe and the interior hole opening of the structure. The connector shall be the only component to
affect the seal between the pipe and structure.
The connector shall be made from materials that conform to the physical and
chemical requirements outlined in Section 4, Materials and Manufacture of
ASTM C-923 Standard Specification for Resilient Connectors between Reinforced
Concrete Manhole Structures, Pipes, and Laterals, and the overall design will meet
or exceed Section 7, Test Methods and Requirements of ASTM C-923.

Copyright ASTM INTERNATIONAL. Reprinted with permission

The connector shall be sized specifically for the type of pipe being used and shall
be installed in accordance with the recommendations of the manufacturer.

INSTALLATION INSTRUCTIONS

DIMENSIONAL DATA

STEP 1:
Confirm that the pipe surface is smooth, clean
and free of foreign materials, chips, gouges and
form seams due to manufacturing or handling.
Slightly bevel any sharp or blunt edges caused by
the cutting of the pipe.

ALOK X-CEL Cross Sections / Pipe Size ODs


92 Molded Series
4.25 - 7.25

93 Molded Series
8.50 - 13.00

93 Extruded Series
13.25 - 29.00

STEP 2:
Lubricate the connector and the entire section
of the pipe that will be inserted into the connector. The chart below lists A-LOKs minimum
lubrication length L.

94 Extruded Series
30.00 - 59.50

PIPE SIZE
4 - 15
16 - 18
21 & Larger

95 Extruded Series
60.00 - 87.50

STEP 3:
Center the pipe and connector square to each other
and insert the pipe into the connector using a
bar or back hoe depending on the size. Once
the pipe is coupled with the connector, deflect the
structure or pipe to achieve the proper angle.

Larger Sizes Available


Upon Special Request

WARNING
To ensure the A-LOK X-CEL Connector remains
a flexible watertight connector, it is A-LOK
Products, Inc. strong recommendation that no
mortar be placed between the pipe and wall of
the concrete structure. The use of mortar in this
area would decrease the effectiveness of the connector to compensate for shear caused by settlement or ground movement.

MAX. PIPE SIZE ODs


Manhole
Diameter
42
48
60
72
84
96
108
120

135 - 225
Pipe Angle
26.5
31.5
42.0
52.5
59.5
73.5
76.0
85.0

90
Pipe Angle
22.0
25.0
32.0
38.0
44.0
50.0
56.0
62.0

MIN. LUBRICATION LENGTH L


12
18
24

CAUTION:
When installing pipe
stubs for future pipeline
installation, all stubs
must be properly
restrained to prevent any
movement by means
other than the A-LOK
X-CEL Connector.

NOTE:
To find approximate subgrade, measure from the
outside base of the structure to the junction of the
connector and flat spot. Then add the wall thickness of the pipe plus 1/4 inch.

ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com
800-822-2565 215-547-3366 215-547-5260 FAX

The Company With Connections


PIPE-TO-MANHOLE AND LATERAL CONNECTORS

INSERTALOK
ALOK INSERTALOK
The INSERTALOK Pipe to
Manhole Connector and
INSERTALOK MD Lateral
Connector are flexible connectors specifically engineered to
produce a positive watertight
seal for pipes entering precast
concrete structures and the
structure itself. The
INSERTALOK Connectors are
manufactured to meet or exceed
the requirements set forth in
ASTM C-923 titled Resilient
Connector Between Reinforced
Concrete Structures and Pipe.

PRODUCT REFERENCES
A.) ASTM C-923
Resilient Connector Between Reinforced Concrete
Manholes Structures and Pipe.

B.) ASTM C-1244


Standard Test Method For Concrete Sewer Manholes
by the Negative Air Pressure (Vacuum) Test

C.) ASTM C-478C


Standard Specification for Precast Reinforced Concrete
Manhole Sections

PERFORMANCE STANDARD
The INSERTALOK Connectors meets or exceeds all material and
performance requirements of ASTM Standard C-923 titled Resilient
Connectors Between Reinforced Concrete Manhole Structures and
Pipes.

MATERIAL
The connector is extruded from a compound formulated for wastewater applications and engineered to conform with the Resilient
Material Requirements of section 4.1.1. Alternative compounds are
available for unusual applications upon special order.

PART 6 DIMENSIONAL DATA


INSERTALOK
FOR SANITARY MANHOLES ROUND AND FLATWALL

KEY ADVANTAGES
The INSERTALOK Connectors function on pure compression making
field installation quick and easy. Clean and lubricate both connector
and pipe, center pipe in connector, and insert.
The connector provides a tapered profile which enhances coupling
characteristics by allowing final compression to be gradual, thereby
reducing the overall coupling force.
The INSERTALOK Connectors can be installed in a precision cast or
cored opening as a mainline connector for new construction, a retrofit or a tie in for new construction.
The connector assures a positive watertight connection providing over
7 degrees of omnidirectional deflection to eliminate infiltration and
shear due to settlement or ground movement. This flexibility permits
immediate backfill enhancing project safety, and overcoming the
problems normally encountered with water, running sand and other
unstable trench conditions.

TYPE OF PIPE
4 P VC SDR 35
4 PVC SDR 40
4 DUCTILE
6 PVC SDR 35
6 DUCTILE
8 PVC SDR 35
8 DUCTILE
10 PVC SDR 35
10 DUCTILE
12 PVC SDR 35
12 DUCTILE

Nominal
Pipe O.D.
4.25
4.50
4.75
6.25
6.875
8.50
9.00
10.50
11.25
12.50
13.00

InsertaLOK InsertaLOK MD
HOLE SIZE
HOLE SIZE

5.00

5.25

5.50

7.00

7.625
10.00
9.25
10.50
9.75
12.00
11.50
12.50
12.00
14.00
13.25
14.50
13.75

FOR LATERAL CONNECTORS YOU MUST USE


MD INSERTALOK WITH 2 STAGE CORE BIT

PERFORMANCE STANDARD
RESILIENT TEST REQUIREMENTS OF A.S.T.M. C-923
TEST

RESULTS

ASTM METHOD

Chemical resistance
1 N Sulfuric acid
1 N Hydrochloric
Acid

no weight loss
no weight loss

at 22C for 48h

Tensile strength

1200 psi or
8.5 MPa, min

D 412

Elongation at break

350% min.

Hardness

5 from mfgs.
specified hardness

D 2240
(Shore A
durometer)

Accelerated
oven-aging

decr. of 15%,
max. of original
tensile strength,
decr. of 20%
max. of elongation

D 573,
701C for
7 days

Compression set

decr. of 25%,
max. of original
deflection

D 395, Method B,
at 70C for 22h

Water absorption

increase of 10%,
max. of original
by weight

D 471, immerse
0.75 by 2-in. or
19 by 25-mm
Specimen in
distilled water
at 70C for 48h

Ozone resistance

rating 0

D 1171

Low-temperature
brittle point

no fracture at
-40C

D 746

Tear resistance

200 lbf/in.
or 34 kn/m

D 624, Method B

PRODUCT SPECIFICATIONS
A flexible pipe to manhole connector shall be used for sanitary and
drain pipe penetrations into precast concrete manholes and structures.
The connector shall be the INSERTALOK CONNECTOR as manufactured by ALOK PRODUCTS, INC., Tullytown, PA, or approved
equal.
The design of the seal shall provide a flexible, positive watertight connection between the pipe and concrete wastewater structures. The
connector shall assure that a seal is made between (1) the connector and the structure wall, and (2) between the connector and the
pipe. The seal between the connector and the structure wall will be
made by pure compression of the resilient material against the wall
of the structure. The seal between the connector and the pipe will be
made by pure compression of the resilient material against the outside diameter of the pipe. The connector shall be the only component
to affect the seal between the pipe and structure.
The connector shall be extruded and vulcanized from materials
whose physical/chemical properties meet or exceed the
physical/chemical resistant properties outlined in ASTM C-923.
The connector shall be of size specifically designed for the pipe material being used and shall be installed in accordance with the recommendations of the manufacturer.

INSTALLATION INSTRUCTIONS
INSTALLATION OF CONNECTOR INTO WALL

INSTALLATION OF PIPE INTO CONNECTOR

IMPORTANT:

BEVEL AND LUBRICATE PIPE


ALSO CENTER PIPE BEFORE
PUSHING PIPE HOME
LUBRICATE INSIDE OF
INSERTALOK CONNECTOR

WARNING: To ensure the INSERTALOK Connector remains a flexible, watertight joint, it is ALOK Products, Inc. strong recommendation that no mortar be placed between the pipe and wall of the precast concrete unit. The use of mortar in this area would
eliminate the flexibility for which the connector was designed and cause problems of shear.
NOTE: Approximate subgrade of trench at the structure can be determined by measuring from the bottom of the connector or flat
spot if present, tot he bottom of the manhole and wall thickness of pipe.
CAUTION: When installing pipe stubs for future pipeline, installation of all stubs should be properly restrained to prevent any movement by means other than, and in addition to, the resilient connector.
ANY QUESTIONS REGARDING ALOK INSERTALOK INSTALLATION, PLEASE CALL 1-800-822-2565
ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@alok.com
800-822-2565 215-547-3366 215-547-5260 FAX

The Company With Connections


SPECIALLY DESIGNED MANDREL AND MAGNETIC HOLDER

MAGNETIC MANDREL SYSTEM


ALOK MAGNETIC MANDREL SYSTEM

KEY ADVANTAGES
Faster set-up
No drilling or cutting of core
Special curved magnet face to maximize
form contact
Magnet possesses great magnetic strength,
high residual magnetism, strong coercive
force and good stability
Mandrels offer excellent chemical and
abrasion resistance
Available for inside or outside mount
Compatible with wet and dry applications

WARNING
DO NOT SUBJECT MAGNETS TO BLUNT FORCE IMPACT.
PROLONGED TEMPERATURES ABOVE 160F WILL CAUSE LOSS OF MAGNETIC ENERGY.
DO NOT WELD NEAR MAGNETS.
AVOID HIGH ELECTRICAL CURRENTS NEAR MAGNETS.

ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@alok.com
800-822-2565 215-547-3366 215-547-5260 FAX

The Company with Connections

TM

CUSTOM MADE FIBERGLASS HOLDERS FOR CONNECTORS

FIELD SLEEVES

For Curved or Flat Wall Structures

FIBERGLASS FIELD SLEEVES


An alternative method
to cast a watertight
connector into a
concrete structure.
They can be used in
the plant or poured
in place in the field.
Each field sleeve is
custom built to fit a
particular structure
that will fit any size of
Tightening down one piece spliced
our connectors.

FIELD SLEEVE INSTALLATION


Into an Opening in an Existing
Round or Flat Wall Structure
HOLE
OPENING IN
WALL MUST
BE 3
LARGER
THAN THE
REPAIR
SLEEVE

ZLOK
Connector

CONNECTORS

Step 1.
Check XCEL or ZLOK in
ALOK Field Sleeve and
pipe O.D. to make sure they
are correct.
Step 2.
Make a perimeter, on the
structure, three (3) inches
larger than the outside
diameter of the ALOK Field
Sleeve.
Step 3.

Fiberglass
Housing

-ALOK STM
-ZLOK
-ZLOK STM
-Premium
-XCEL
-QuikLOK
-Septic Seals

On this perimeter either:


a.) Core the entire opening
to create a hole.
b.) Drill a series of one (1)
inch or larger holes no
more than 5 inches apart
so a jackhammer can be
used to create an opening
for the Field Sleeve.
Step 4.
Set up ALOK Field Sleeve
in opening on correct
grade. Pack annular space
between opening and

Non-Shrink
Grout

firmly with non-shrink


grout. Carefully follow grout
manufacturers instructions
for mixing, placing and
curing.
XCEL
Connector

Step 5.
Once grout is cured,
review Pipe Installation
Instructions for ZLOK or
XCEL Connectors on side
2 of these instructions.

Introducing A-LOKs Newest Product


Exclusively Distributed by

P.O. Box 1647


Tullytown, PA 19007
800-822-2565
215-547-5260 (fax)

GrandSlam Lubricant is a new material specifically formulated for pipe penetrations


into all A-LOK connectors as well as joining all types of pipes in trenches and manholes.

Very Slippery! GrandSlam Lubricant reduces friction of the gasket against the
bell and the pipe against the connector. It helps pipe slide in smoothly minimizing the
possibility of the gasket to displace and cause bell damage or the beveled pipe to tear
the connector.

Special Wax Technology! GrandSlam contains a special wax that fills in the
microscopic pores in concrete. By filling in the pores, gaskets slide rather than catch on
the concrete surface.

Clean and Neat to Use! GrandSlam Lubricant washes off hands, tools and
clothing with soap and water. It has no bad smell and does not get soupy, so field
crews are more willing to apply it properly ensuring good field performance.

Easy to Apply! GrandSlam Lubricant clings to everything! Gaskets, connectors,


concrete, PVC, ductile iron, HDPE, clay, and steel surfaces. Its unique formulation
keeps the lubricant where it belongs whether applied by hand, swab or brush. A totally
lubricated area minimizes the threat of damage during installations.

Compatible! GrandSlam Lubricant does not affect or swell rubber or plastic


gaskets. It contains no hydrocarbon or silicone greases. It does not affect gaskets
over time to cause eventual leakage or breakage.

Safe and Non Toxic! Harmless to people and the environment when used as
directed. Can be safely used in the field. Suitable for potable water systems. Meets
NSF/ANSI Standard 61.

By preventing even one damaged pipe per month, GrandSlam Lubricant can pay for itself
over and over again!
GrandSlam Summer Grade

GrandSlam Winter
Grade

Package Size

GSQ-128

GWQ-128

1 gal. pail (4/cs)

GSQ-448

GWQ-448

3.5 gal. pail (1 ea)

GSQ-640

GWQ-640

5 gal. pail (1 ea)

Application & Installation


1. GrandSlam Lubricant is ready to use in the pail. Do not dilute, thin, or otherwise alter
its consistency. For best results lubricate surfaces right before making connections.
2. Clean all surfaces before applying lube. Outside the pipe and all over the connector for
pipe penetrations. Inside the bell outside the spigot for pipe to pipe.
3. For pipe penetrations into a connector, bevel the pipe, lubricate the connector all around,
then lubricate the pipe back its diameter up to 21.
4. The lubricant can be brushed on, swabbed on, or wiped on by hand with a cloth glove. Be
sure to get full lubricant coverage. Dont leave any area DRY. GrandSlam Lubricant
makes such applications easy by grabbing and clinging to all surfaces.
5. Because GrandSlam lubricant will adhere when applied under water, steps 1-6 can be
done in the rain or in a wet trench just like an A-LOK pipe installation.
6. After lubrication, a pipe can be centered and inserted into a connector or pipes can be
aligned and joined by an approved coupling method.
7. For pipe to pipe installations position the gasket in the groove and equalize its stretch by
lifting it slightly with a screwdriver while completely circling the pipe. Apply lubrication on
top of the newly inserted gasket using one of the methods in step 4.
Specifications:
Lubricant

Description

Gasket
HighCompatibility Temperature
Separation

Coating
Properties

Adhesion to
Wet
Concrete

Freezing
Point

GrandSlam
Summer
Grade

High solids
with wetting
agents; waterbased paste

<1.0% Wt.
Gain
<1 Duro Pts.

Spreads
smoothly and
evenly
No washout

Spreads
smoothly and
evenly
No washout

32F

GrandSlam
Winter Grade

High solids
with wetting
agents; waterbased paste

<1.0% Wt.
Gain
<1 Duro Pts.

Spreads
smoothly and
evenly
No washout

Spreads
smoothly and
evenly
No washout

10F

Retains
thickness and
appearances
at high
temperatures
Retains
thickness and
appearances
at high
temperatures

Copyright 2003. American Polywater Corporation. All Rights Reserved


Important Notice: The statements here are made in good faith based on tests and observations we believe to be
reliable. However, the completeness and accuracy of the information is not guaranteed. Before using, the enduser should conduct whatever evaluations are necessary to determine that the product is suitable for the intended
use.
American Polywater expressly disclaims any implied warranties and conditions of merchantability and fitness for a
particular purpose. American Polywater's only obligation shall be to replace such quantity of the product proven to
be defective. Except for the replacement remedy, American Polywater shall not be liable for any loss, injury, or
direct, indirect, or consequential damages resulting from products use, regardless of the legal theory asserted.
LIT-GSQFLYER/11-09/INTERNAL

P.O. Box 53
Stillwater, MN 55082
U.S.A
custserv@polywater.com (e-mail)
http://www.polywater.com(URL)

1-800-328-9384
1-651-430-2270
fax 1-651-430-363

The Company With Connections

TM

PIPE TO CONCRETE STRUCTURE COLD JOINT CONNECTOR

WATER-STOP For all Corrugated or Smooth Wall Pipes


WATER-STOP CONNECTORS
WATER-STOP
Connectors easily
install to the outside
diameter of corrugated
or smooth wall pipe.
Designed for use with
new or existing round
or flat wall structures
to seal cold joint pipe
penetrations.

MATERIAL

PERFORMANCE STANDARD
WATER-STOP passes ASTM C-1244 Vacuum Test and meets and
exceeds all material and test requirements of ASTM 1478 and ASTM
C-923 Resilient Materials Test, Section 4: Resilient Connectors
Between Reinforced Concrete Manhole Structures, Pipes and
Laterals.
See following chart:

RESILIENT TEST REQUIREMENTS OF A.S.T.M. C-923

(Fig. 1) Tightening down one piece spliced


WATER-STOP with torque wrench prior to
grouting.

TEST

RESULTS

ASTM METHOD

Chemical resistance
1 N Sulfuric acid
1 N Hydrochloric
Acid

no weight loss
no weight loss

at 22C for 48h

1200 psi or
8.5 MPa, min

D 412

Tensile strength
Elongation at break

350% min.

Hardness

WATER-STOP is extruded from an Polyisoprene/SBR blend


compound engineered to conform with the requirements of Section
4.1.1 of ASTM C-923. Alternative compounds are available for
unusual applications upon special order.

5 from mfgs.
specified hardness

D 2240
(Shore A
durometer)

Accelerated
oven-aging

D 573,
701C for
7 days

All stainless steel hardware is in compliance with Section 4.2,


Mechanical Devices of ASTM C-923.

decr. of 15%,
max. of original
tensile strength,
decr. of 20%
max. of elongation

Compression set

decr. of 25%,
max. of original
deflection

D 395, Method B,
at 70C for 22h

Water absorption

increase of 10%,
max. of original
by weight

D 471, immerse
0.75 by 2-in. or
19 by 25-mm
Specimen in
distilled water
at 70C for 48h

Ozone resistance

rating 0

D 1171

Low-temp
brittle point

no fracture at
-40C

D 746

Tear resistance

200 lbf/in.
or 34 kn/m

D 624, Method B

KEY ADVANTAGES
The WATER-STOP profile provides a better surface than PVC or
corrugated HDPE for grout to adhere as well as a watertight connection
between the connector and pipe. The Special T profile also helps
prevent water and soil infiltration for all types of pipe. This connector is
made from a Polyisoprene SBR blend. The WATER-STOP Wedge Kit
(see Fig. 2) can easily be installed around existing pipes during the
rehabilitation process.

Copyright ASTM INTERNATIONAL. Reprinted with permission

The one piece spliced WATER-STOP (see Fig. 1) is normally installed


over the end of new pipe installations such as field poured structures,
mortared connections to precast structures, casting pipe hubs into
concrete structures and doghouse field poured collars.

PRODUCT REFERENCES
A.) ASTM C-923
Resilient Connector Between Reinforced Concrete
Manholes Structures, Pipe and Laterals.

DIMENSIONAL DATA
Plus or minus 1" of the nominal pipe O.D. When ordering for corrugated
pipe, it is important to specify the pipe manufacturer and the O.D. of the
crest of the corrugation, if possible, for proper fit.
Up to 18" corrugated uses single clamp as does all sizes of smooth wall
pipe.
24" corrugated pipe and above uses double clamp connector design.

B.) ASTM C-1244


Standard Test Method For Concrete Sewer Manholes
by the Negative Air Pressure (Vacuum) Test

C.) ASTM 1478


Resilient Connectors Between Reinforced Concrete
Storm Sewer Structures, Pipes and Laterals.

Double clamp WATER-STOP profile


for corrugated over 18" diameter.

Single clamp WATER-STOP profile


for all smooth wall and less than
18" diameter corrugated pipe.

WEDGE STYLE WATER-STOP KIT

COMPONENTS: Connector to fit Pipe O.D.


Tube of Glue
1 Rubber Wedge
2 Steel Alignment Pins

(Fig. 2)

INSTALLATION INSTRUCTIONS (Existing Pipe)

STEP 1

STEP 2

STEP 3

Insert pins in wedge and apply glue to both


sides of wedge.

Wrap WATER-STOP around pipe. Install pins


and wedge to WATER-STOP.

Torque down take down clamp to 60" pounds to


squeeze wedge with glue together. Once glue is
set grouting can begin.

ONE PIECE SPLICED STYLE WATER-STOP


INSTALLATION INSTRUCTIONS (New Pipe)
CORRUGATED PIPE FOR SIZES 18" AND ABOVE

1. Cast or core an opening in the structure 5"


larger than the O.D. of the pipe.
2. Center one piece Water-Stop CPP over the
crest of pipe corrugation.

3. Position the take down clamp(s) in grooves


of Water-Stop CPP. Then torque clamp(s) to
60 in.- lbs. with Torque wrench.
4. Align pipe and connector in center of
structure opening and mortar completely
around annular space with non-shrink grout.
3

5. If pouring in place, vibrate properly to insure


complete compaction around seal.
NOTE: Up to 15" use a single clamp
connector design and 18" and above use
double clamp connector design.

NOTE: The 60 in.-lb. Torque Wrench is


available through ALOK Products, Inc.

ANY QUESTIONS REGARDING WATER-STOP CONNECTOR, PLEASE CALL 1-800-822-2565

ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com
800-822-2565 215-547-3366 215-547-5260 FAX

7/07

The Company With Connections


PIPE TO MANHOLE CONNECTOR FOR SANITARY OR STORMWATER SYSTEMS

G3 BOOT SYSTEM
ALOK G3 BOOT SYSTEM
The Revolutionary
G3 Band makes
installation into a
structure simple
and fast. Just install
the connector
perpendicular to the
hole and tighten the
stainless steel nut. As
the nut is tightened, a
compressive force is
applied to the G3
band ends, causing
them to slide past
each other into
straight alignment.
G3 BOOT SYSTEM
This movement
WITH
increases the bands
COMPONENT PACKAGING
overall circumference
AND TORQUE WRENCHES
and compresses the
connector against the
opening in the structure wall, creating a watertight seal. To insure
the best seal, place the bolt in the 12 oclock position of the hole
opening and tighten the nut to the specified torque value.

MATERIAL
The connector shall be made from materials that conforms to the
physical and chemical requirements outlined in Section 4, Materials
and Manufacture of ASTM C-923 Standard Specification for
Resilient Connectors Between Reinforced Concrete Manhole
Structures, Pipes, and Laterals, and the overall design will meet or
exceed Section 7, Test Methods and Requirements of ASTM C923.
The connector shall be sized specifically for the type of pipe being
used and shall be installed in accordance with the recommendations
of the manufacturer.

KEY ADVANTAGES
The G3 Boot System can withstand 15 of omnidirectional
deflection and of centerline offset while still maintaining a
watertight connection. This flexibility eliminates infiltration due to
pipe shear caused by settlement or ground movement.
The inner O-ring design of the G3 Connector eliminates rubber
wrinkling, compensates for pipe irregularity and wall thickness to
insure a watertight seal.
G3 Component Packaging, featuring a tough loop lock fastener
that keeps installation instructions, take down clamp, boot and
band secure together from factory to job site.

PRODUCT SPECIFICATIONS
A flexible pipe to manhole connector shall be used whenever a pipe
penetrates into a precast concrete manhole or structure.
The connector shall be the G3 Boot System featuring component
packaging as manufactured by ALOK PRODUCTS, INC.,
Tullytown, PA, or approved equal.
The design of the connector shall provide a flexible, watertight seal
between the pipe and concrete structure. The connector shall
assure that a seal is made between (1) the connector and the
structure wall by placing the connector and expansion band into
the center third of the concrete hole opening. The band is then
expanded by tightening the expansion mechanism increasing the
bands overall circumference and compressing the connector
against the sides of the hole opening. (2) The seal between the
connector and the pipe shall be made by compressing the
connector against the outside circumference of the pipe by means
of a stainless steel take-down band.

PART 6 DIMENSIONAL DATA


G3 BOOT SIZE LIST
ITEM

PRODUCT REFERENCES
G3 Boot System meets or exceeds requirements of ASTM C-923

G3-0804
G3-1206
G3-1208
G3-1410
G3-1612

PIPE O.D.
RANGE
Min.-Max.
3.50-4.50
6.0-6.875
8.0-9.5
10.0-11.25
12.0-13.5

HOLE
SIZE
8
12
12
14
16

PERFORMANCE STANDARD

INSTALLATION INSTRUCTIONS

ASTM C-923 Section 4.1


RESILIENT MATERIALS TESTS
TEST
Chemical resistance
1 N Sulfuric acid
1 N Hydrochloric
acid

RESULTS

ASTM METHOD

no weight loss
no weight loss

D 543,
at 22C for 48h

Tensile strength

1200 psi, min.

D 412

Elongation at break

350% min.

HardnessB

5 from mfgs.
specified hardness

D 2240
(Shore A durometer)

Accelerated
oven-aging

decr. of 15%,
max. of original
tensile strength,
decr. of 20%
max. of elongation

D 573,
701C for
7 days

Compression set

decr. of 25%,
max. of original
deflection

D 395, Method B,
at 70C for 22h

Water absorption

increase of 10%,
max. of original
by weight

D 471, immerse
0.75 by 2-in. or
19 by 25-mm
Specimen in
distilled water
at 70C for 48h

Ozone resistance

rating 0

D 1171

Low-temperature
brittle point

no fracture at
-40C

D 746

Tear resistance

200 lbf/in.

D 624, Die B

Copyright ASTM INTERNATIONAL. Reprinted with permission

1) Position G31208 Boot &


Band in hole,
then tighten to
25 ft-lbs using
torque wrench.

2) Insert pipe into


rolled in
connector. For
inside mount,
affix clamp
behind O-ring.
Torque to 60
in-lbs and
backfill.

3) For outside
mount: pull pipe
back, reposition
pipe within the
wall and affix
clamp directly
behind O-ring.
Torque to 60 inlbs and backfill.

WARNING: To ensure the G3 Boot System remains a flexible watertight connector, it


is ALOK Products, Inc. strong recommendation that no mortar be placed between
the pipe and wall of the concrete structure. The use of mortar in this area would
decrease the effectiveness of the connector to compensate for shear caused by
settlement or ground movement.
NOTE: ALOK strongly suggests use of proper torque wrenches to secure the G3
Boot in the structure as well as to secure the takedown clamp around the
connector and pipe. Both torque wrenches are available through ALOK Products,
Inc.
CAUTION: When installing pipe stubs for future pipeline installation, all stubs must
be properly restrained to prevent any movement by means other than the G3
Connector.
ANY QUESTIONS REGARDING G3 BOOT SYSTEM, PLEASE CALL 1-800-822-2565

ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@alok.com
800-822-2565 215-547-3366 215-547-5260 FAX

The Company With Connections

TM

PIPE TO MANHOLE CONNECTOR FOR SANITARY SYSTEMS

ZLOK CAST IN BOOT CONNECTOR


ZLOK PIPE TO MANHOLE CONNECTOR
The ZLOK Pipe to
Manhole Connector is
a flexible connector
specifically engineered
to produce a positive
watertight seal for
pipes entering precast
concrete structures and
the structure itself.
Its heavier wall is
designed to provide the
highest performance.
The ZLOK
CONNECTOR is
manufactured to meet
or exceed the
requirements set forth
in ASTM C-923 titled
Resilient Connectors
Between Reinforced
Concrete Manhole
Structures, Pipes, and
Laterals.

MATERIAL
The ZLOK CONNECTOR is molded from an EPDM compound
engineered to conform with the requirements of section 4.1.1 of
ASTM C-923. Alternative compounds are available for unusual
applications upon special order.
All stainless steel hardware is in compliance with section 4.2,
Mechanical Devices of ASTM C-923.

KEY ADVANTAGES

PRODUCT REFERENCES
A.) ASTM C-923
Resilient Connector Between Reinforced Concrete
Manholes Structures, Pipe and Laterals.

B.) ASTM C-1244


Standard Test Method For Concrete Sewer Manholes
by the Negative Air Pressure (Vacuum) Test

C.) ASTM C-478


Standard Specification for Precast Reinforced Concrete
Manhole Sections

PERFORMANCE STANDARD
The ZLOK Connector meets or exceeds all material and test
requirements of ASTM C-923: Resilient Connectors Between
Reinforced Concrete Manhole Structures, Pipes and Laterals.
See following chart:

RESILIENT TEST REQUIREMENTS OF A.S.T.M. C-923


TEST

RESULTS

ASTM METHOD

Chemical resistance
1 N Sulfuric acid
1 N Hydrochloric
Acid

no weight loss
no weight loss

at 22C for 48h

1200 psi or
8.5 MPa, min

D 412

Tensile strength
Elongation at break

350% min.

The ZLOK CONNECTOR assures a positive watertight connection and


provides up to 25 of omnidirectional deflection and 1.50" of vertical or
horizontal movement without loss of seal, providing greater flexibility in
the design and installation of pipelines and structures. These design
features of the ZLOK CONNECTOR prevent infiltration due to shear
caused by settlement or ground movement.

Hardness

5 from mfgs.
specified hardness

D 2240
(Shore A
durometer)

Accelerated
oven-aging

decr. of 15%,
max. of original
tensile strength,
decr. of 20%
max. of elongation

D 573,
701C for
7 days

The inner rubber O-ring design eliminates rubber wrinkling,


compensates for pipe irregularity and wall thickness insuring a
watertight seal.

Compression set

decr. of 25%,
max. of original
deflection

D 395, Method B,
at 70C for 22h

Water absorption

increase of 10%,
max. of original
by weight

D 471, immerse
0.75 by 2-in. or
19 by 25-mm
Specimen in
distilled water
at 70C for 48h

Ozone resistance

rating 0

D 1171

Low-temp
brittle point

no fracture at
-40C

D 746

Tear resistance

200 lbf/in.
or 34 kn/m

D 624, Method B

The unique bi-directional design, permits the ZLOK CONNECTOR


take-down clamp to be fastened from either the inside or outside of the
structure. Once fastened, immediate backfilling is possible enhancing
project safety and overcomes the normal problems encountered with
water, running sand and other unstable trench conditions.
When casting the ZLOK CONNECTOR into the structure, making it an
integral part of the wall, 50% of the opportunity for infiltration is
eliminated.

Copyright ASTM INTERNATIONAL. Reprinted with permission

PART 6 DIMENSIONAL DATA


Z-LOK
RING NO.
C107-1
C107-2
C107-3
C107-4
C107-6
F208-8
C107-8
C107-10
C107-12
C107-15
C107-16
C107-18

PIPE O.D.
MIN.
1.25
2.00
2.75
4.25
6.25
8.25
8.25
10.25
12.25
14.25
16.25
18.25"

INCHES
MAX.
1.75
2.50
3.75
6.25
8.25
9.10
10.25
12.25
14.25
16.00
18.00
21.25"

PRODUCT SPECIFICATIONS

CLAMP
NUMBER
CL-040
CL-040
CL-088
CL-088
CL-128
CL-188
CL-188
CL-188
CL-248
CL-EV15-18-L
CL-EV15-18-L
CL-EV15-18-L

NOTE:
F208-8 GASKET CAN BE USED ON C107-6 MANDREL
WHEN ORDERING CLAMPS, PIPE ODS ARE REQUIRED
C107-1 AND C107-2 USE THE SAME MANDREL
C107-16 AND C107-18 USE THE SAME MANDREL
REDI-LOK CLAMP IS REQUIRED FOR C107-15
THROUGH C107-18 GASKETS

The connector shall be the ZLOK CONNECTOR as manufactured by ALOK


PRODUCTS, INC., Tullytown, PA, or approved equal.
The design of the connector shall provide a flexible, watertight seal between the pipe
and concrete structure. The connector shall assure that a seal is made between:
(1) The connector and the structure wall by casting the connector
integrally with the structure wall during the manufacturing process in a manner
that it will not pull out during pipe coupling.
(2) The seal between the connector and the pipe shall be made by compressing
the connector against the outside circumference of the pipe by means of a
stainless steel take-down band.
The connector shall be made from materials that conform to the physical and
chemical requirements outlined in Section 4, Materials and Manufacture of
ASTM C-923 Standard Specification for Resilient Connectors Between
Reinforced Concrete Manhole Structures, Pipes, and Laterals, and the overall
design will meet or exceed Section 7, Test Methods and Requirements of ASTM
C-923.
The connector shall be sized specifically for the type of pipe being used and shall
be installed in accordance with the recommendations of the manufacturer.

INSTALLATION INSTRUCTIONS

60 IN. LBS.
TORQUE
WRENCH
INSIDE
OF
MANHOLE
DO NOT
MORTAR
TOP HALF
OF PIPE
LINE

A flexible pipe to manhole connector shall be used whenever a pipe


penetrates into a precast concrete manhole or structure.

Z-LOK CONNECTOR INWARD POSITION


STEP 1:
Bevel pipe.
Clean connector.
Clean pipe of
dirt & debris.
OUTSIDE
OF
MANHOLE
DO NOT
MORTAR

INSIDE Z-LOK CONNECTOR INSTALLATION


STEP 2:
Center pipe in connector and
push through.
STEP 3:
Attach proper size clamp
beside o-ring then center
pipe in connector and VERY
IMPORTANT tighten clamp
with torque wrench to 60
inch pounds.

WARNING: To ensure the Z-LOK Connector remains a flexible


watertight connector, it is ALOK Products, Inc. strong
recommendation that no mortar be placed between the pipe and
wall of the concrete structure. The use of mortar in this area would
decrease the effectiveness of the connector to compensate for
shear caused by settlement or ground movement.
OUTSIDE INSTALLATION

NOTE: The 60 in.-lb. Torque Wrench is available through ALOK


Products, Inc.
CAUTION: When installing pipe stubs for future pipeline installation,
all stubs must be properly restrained to prevent any movement by
means other than the Z-LOK Connector.
ANY QUESTIONS REGARDING Z-LOK CONNECTOR,
PLEASE CALL 1-800-822-2565

STEP 4:
When installing a Z-LOK
connector in the outside the
manhole position pull pipe
back out after inserting so
the connector flips outward,
then VERY IMPORTANT center pipe in connector
and tighten the take down
clamp to 60 inch pounds
with a torque wrench.

ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com
800-822-2565 215-547-3366 215-547-5260 FAX

8/06

The Company With Connections

TM

A BOOT STYLE CONNECTOR FOR SANITARY OR STORMWATER SYSTEMS

ZLOK STM
ZLOK STM

PRODUCT REFERENCES
A.) ASTM C-923

The ZLOK STM CONNECTOR was designed by A-LOK Products,


Inc. to address the need for a boot style connector for large diameter
pipe. This makes it ideally suited for sanitary applications, using
smooth wall pipe or corrugated pipe with a factory installed smooth
over sleeve and stormwater applications, with corrugated or smooth
wall pipe. Available for 6"-102" pipes.

Resilient Connector Between Reinforced Concrete


Manholes Structures, Pipe and Laterals.

B.) ASTM C-1478


Resilient Connectors Between Reinforced Concrete
Storm Sewers Structures, Pipes and Laterals.

The ZLOK STM Pipe to


Manhole Connector is a
flexible connector
specifically engineered to
produce a positive
watertight seal for pipes
entering precast concrete
structures and the
structure itself.

C.) ASTM C-1244


Standard Test Method For Concrete Sewer Manholes
by the Negative Air Pressure (Vacuum) Test.

PERFORMANCE STANDARD

ZLOK STM Connector


cast into storm structure.

MATERIAL
The ZLOK STM CONNECTOR is molded from a polyisoprene
compound engineered to conform with the requirements of section
4.1.1 of ASTM C-923. Alternative compounds are available for
unusual applications upon special order.
All stainless steel hardware is in compliance with section 4.2,
Mechanical Devices of ASTM C-923.

KEY ADVANTAGES
The ZLOK STM CONNECTOR assures a positive watertight
connection and provides up to 15 of omnidirectional deflection and
1.50" of vertical or horizontal movement without loss of seal,
providing greater flexibility in the design and installation of pipelines
and structures. These design features of the ZLOK STM
CONNECTOR prevent infiltration due to shear caused by settlement
or ground movement.
Once fastened, immediate backfilling is possible enhancing project
safety and overcomes the normal problems encountered with water,
running sand and other unstable trench conditions.
When casting the ZLOK STM CONNECTOR into the structure,
making it an integral part of the wall, 50% of the opportunity for
infiltration is eliminated.

14

The ZLOK STM Connector meets or exceeds all material and test
requirements of ASTM C-923-00: Resilient Connectors Between
Reinforced Concrete Manhole Structures, Pipes and Laterals.
See following chart:

RESILIENT TEST REQUIREMENTS OF A.S.T.M. C-923


TEST

RESULTS

ASTM METHOD

Chemical resistance
1 N Sulfuric acid
1 N Hydrochloric
Acid

no weight loss
no weight loss

at 22C for 48h

1200 psi or
8.5 MPa, min

D 412

Tensile strength
Elongation at break

350% min.

Hardness

5 from mfgs.
specified hardness

D 2240
(Shore A
durometer)

Accelerated
oven-aging

decr. of 15%,
max. of original
tensile strength,
decr. of 20%
max. of elongation

D 573,
701C for
7 days

Compression set

decr. of 25%,
max. of original
deflection

D 395, Method B,
at 70C for 22h

Water absorption

increase of 10%,
max. of original
by weight

D 471, immerse
0.75 by 2-in. or
19 by 25-mm
Specimen in
distilled water
at 70C for 48h

Ozone resistance

rating 0

D 1171

Low-temp
brittle point

no fracture at
-40C

D 746

Tear resistance

200 lbf/in.
or 34 kn/m

D 624, Method B

Copyright ASTM INTERNATIONAL. Reprinted with permission

ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com
800-822-2565 215-547-3366 215-547-5260 FAX

PRODUCT SPECIFICATIONS
A flexible pipe to manhole connector shall be used whenever a pipe
penetrates into a precast concrete manhole or structure.
The connector shall be the ZLOK STM CONNECTOR as manufactured by
ALOK PRODUCTS, INC., Tullytown, PA, or approved equal.
The design of the connector shall provide a flexible, watertight seal between the pipe
and concrete structure. The connector shall assure that a seal is made between:
(1) The connector and the structure wall by casting the connector
integrally with the structure wall during the manufacturing process in a manner
that it will not pull out during pipe coupling.
(2) The seal between the connector and the pipe shall be made by compressing
the connector against the outside circumference of the smooth wall pipe or
against the inside walls of the valley of the corrugated pipe by means of a
stainless steel take-down clamp.
The connector shall be made from materials that conform to the physical and
chemical requirements outlined in Section 4, Materials and Manufacture of
ASTM C-923 Standard Specification for Resilient Connectors Between
Reinforced Concrete Manhole Structures, Pipes, and Laterals, and the overall
design will meet or exceed Section 7, Test Methods and Requirements of ASTM
C-923, using smooth wall pipe or corrugated pipe with a factory installed smooth
over sleeve, and ASTM C-1478 with smooth wall pipe or corrugated pipe.
The connector shall be sized specifically for the type of pipe being used and shall
be installed in accordance with the recommendations of the manufacturer.

FIELD INSTALLATION INSTRUCTIONS


CORRUGATED PIPE

PRECAST INSTALLATION INSTRUCTIONS


ONE-PIECE WEDGE KNOCKOUT
For 6" Flatwall
Pull connector over onepiece Wedge Knockout
Hole Former as shown.
TWO-PIECE MANDREL
For 8" Flatwall and above

1. Stretch gasket over outside mandrel half, with


cut-outs positioned at 3 and 9 oclock.
2. Force gasket down inside mandrel before
installing in form.
3. Use coil nut to tighten gasket and mandrels
together.
TWO-PIECE MANDREL
For Round Manholes

FIELD INSTALLATION
STEP 1:
ZLOK STM Connector cast into storm
structure.

FIELD INSTALLATION INSTRUCTIONS


SMOOTH WALL PIPE
FIELD INSTALLATION
STEP 2:
Pipe is centered through the
connector. The Stainless Steel Clamp
is centered above the valley of pipe
making sure the fastening points are
positioned in the two cutout areas of
the rubber connector.

STEP 3:
Stainless Steel Clamp is tightened
equally about the take-up point to 60
in./lbs. This action compresses the
rubber against the side walls of the
pipe valley and a watertight
connection is formed.

STEP 1:
ZLOK STM Connector cast into storm
structure.

STEP 2:
Pipe is inserted and centered within the
connector to obtain proper mechanical
seal.

STEP 3:
Stainless Steel Clamp is tightened
equally about the take-up point to 60
in./lbs, insuring a watertight connection.
This should be done prior to any pipe
deflection or backfilling.
IMPORTANT: After groove of
pipe is centered in gasket
tighten stainless steel clamp
equally to 60 in. lbs. with an
ALOK Torque Wrench.

SECTION VIEW
WITH PIPE INSTALLED

SECTION VIEW
WITH PIPE
INSTALLED

DIMENSIONAL DATA

Z-LOK STM CONNECTORS


SMOOTH WALL PIPE DATA

ANY QUESTIONS REGARDING ZLOK STM CONNECTOR INSTALLATION, PLEASE CALL 1-800-822-2565

DIMENSIONAL DATA

Z-LOK STM CONNECTORS


CORRUGATED PIPE DATA

COMPONENT IDENTIFICATION
FOR Z-LOK STM CONNECTORS

Smooth Wall Pipe


MANHOLE
DIA.
48" DIA.
5" WALL
60" DIA.
6" WALL
72" DIA.
7" WALL
84" DIA.
8" WALL
96" DIA.
9" WALL

MAX.
O.D. PIPE
28 IN.
30 IN.
37 IN.
44 IN.
51 IN.

Corrugated Pipe

Z-LOK STM PROFILE COMPARISION

Z-LOK STM for Flat Wall

Z-LOK STM for Radius Wall

MANHOLE
DIA.
48" DIA.
5" WALL
60" DIA.
6" WALL
72" DIA.
7" WALL
84" DIA.
8" WALL

MAX.
O.D. PIPE
22 IN.
30 IN.
37 IN.
42 IN.

The Company With Connections

TM

PIPE TO MANHOLE BOOT CONNECTOR FOR SANITARY SYSTEMS

QUIKLOK

Patent Pending

The Boot with the Built-in Clamp

QUIKLOK
The QUIKLOK Pipe to
Manhole Boot Connector is a
flexible connector specifically
engineered to produce a
positive watertight seal for
pipes entering precast concrete
structures and the structure
itself. The QUIKLOK
CONNECTOR is manufactured
to meet or exceed all material
and test requirements set forth
in ASTM C-923 titled
Resilient Connectors
Between Reinforced Concrete
Manhole Structures, Pipes,
and Laterals.

QUIK-LOK boot as it will arrive


with clamp attached ready to
be placed in a mandrel.

QUIK-LOK boot cast into


structure in shipping position.

PERFORMANCE STANDARD

MATERIAL
The QUIKLOK Connector is molded from an EPDM compound
engineered to conform with the requirements of section 4.1.1 of
ASTM C-923. Alternative compounds are available for unusual
applications upon special order.
All stainless steel hardware is in compliance with section 4.2,
Mechanical Devices of ASTM C-923.

KEY ADVANTAGES
The QUIKLOK CONNECTOR assures a positive watertight connection
and provides up to 20 degrees omni-directional deflection and 1.00" of
vertical or horizontal movement without loss of seal. This deflection
permits pipe to structure settling without damage to the pipe or loss of
the watertight seal and will also allow for many angles of incoming pipe.
The QUIKLOK cast in Boot Connector is manufactured with the
stainless steel takedown clamp as an integral part of the rubber
connector.
The correct takedown clamp travels in the installation position from the
time it leaves A-LOK, while it is cast in the structure and until it arrives
at the job site. After pulling out the connector its in position ready to be
tightened down around the pipe on the outside of the structure.

The QUIKLOK CONNECTOR meets or exceeds all material and test


requirements of ASTM C-923 titled Resilient Connectors Between
Reinforced Concrete Manhole Structures, Pipes, and Laterals.
See following chart:

RESILIENT MATERIAL TEST OF ASTM C-923


TEST
Chemical resistance
1 N Sulfuric acid
1 N Hydrochloric
Acid
Tensile strength

RESULTS
no weight loss
no weight loss
1200 psi or
8.5 MPa, min

ASTM METHOD
D 543
at 22C for 48h
D 412

Elongation at break

350% min.

Hardness

5 from mfgs.
specified hardness

D 2240
(Shore A
durometer)

Accelerated
oven-aging

decr. of 15%,
max. of original
tensile strength,
decr. of 20%
max. of elongation

D 573,
701C for
7 days

Compression set

decr. of 25%,
max. of original
deflection

D 395, Method B,
at 70C for 22h

Water absorption

increase of 10%,
max. of original
by weight

D 471, immerse
0.75 by 2-in. or
19 by 25-mm
Specimen in
distilled water
at 70C for 48h

Ozone resistance

rating 0

D 1171

Low-temp
brittle point

no fracture at
-40C

D 746

Tear resistance

200 lbf/in.
or 34 kn/m

D 624, Method B

Immediate backfilling is then possible, enhancing project safety and


overcomes the problems encountered with water, running sand and
other unstable trench conditions.
The QUIKLOK Connector can be installed into concrete structures in
the plant or with a field sleeve for cast-in-place, at the job site. Once
installed in the concrete structure and ready to ship, the QUIKLOK
Connector travels in the cast in position to prevent damage during
shipping and handling.

QUIK-LOK boot extended at job


site ready for pipe.

Copyright ASTM INTERNATIONAL. Reprinted with permission

PRODUCT REFERENCES

PRODUCT SPECIFICATIONS

A.) ASTM C-923


Resilient Connectors Between Reinforced Concrete Manhole
Structures, Pipes, and Laterals.

B.) ASTM C-1244


Standard Test Method For Concrete Sewer Manholes
by the Negative Air Pressure (Vacuum) Test

C.) ASTM C-478


Standard Specification for Precast Reinforced Concrete
Manhole Sections

PART 6 DIMENSIONAL DATA


QUIKLOK
RING NO.
QL-04
QL-06
QL-08
QL-10
QL-12

PIPE OD
MIN.
4"
6"
8"
10"
12"

PIPE OD
MAX.
4.75"
6.875"
9.10"
11.25"
13.00"

A flexible pipe to manhole connector shall be used whenever a pipe


penetrates into a precast concrete manhole or structure.
The connector shall be the QUIKLOK CONNECTOR as manufactured by ALOK
PRODUCTS, INC., Tullytown, PA, or approved equal.
The design of the connector shall provide a flexible, watertight seal between the pipe
and concrete structure. The connector shall assure that a seal is made between:
(1) The connector and the structure wall by casting the connector
integrally with the structure wall during the manufacturing process in a manner
that it will not pull out during pipe coupling.
(2) The seal between the connector and the pipe shall be made by compressing
the connector against the outside circumference of the pipe by means of a
stainless steel take-down band.
The connector shall be made from materials that conform to the physical and
chemical requirements outlined in Section 4, Materials and Manufacture of
ASTM C-923 Standard Specification for Resilient Connectors Between
Reinforced Concrete Manhole Structures, Pipes, and Laterals, and the overall
design will meet or exceed Section 7, Test Methods and Requirements of ASTM
C-923.
The connector shall be sized specifically for the type of pipe being used and shall
be installed in accordance with the recommendations of the manufacturer.

INSTALLATION INSTRUCTIONS
STEP 3

STEP 1

STEP 3: Center pipe and insert.

STEP 1: Remove all sharp edges


on pipe, bevel edge and
clean penetrating pipe
section.

STEP 4

STEP 2

STEP 2: Pull out connector from


cast position and clean
off debris (stones, dirt,
etc.) that could weaken
the sealing area.

STEP 4: After inserting pipe, the


stainless steel band should
be tightened with the
torque wrench to 60 in.-lb.,
then deflect pipe to flow or
angle installation requires.

WARNING: To ensure the QUIKLOK Connector remains a flexible watertight connector, it is ALOK Products, Inc. strong
recommendation that no mortar be placed between the pipe and wall of the concrete structure. The use of mortar in this area would
decrease the effectiveness of the connector to compensate for shear caused by settlement or ground movement.
NOTE: The 60 in.-lb. Torque Wrench is available through ALOK Products, Inc.
CAUTION: When installing pipe stubs for future pipeline installation, all stubs must be properly restrained to prevent any movement by
means other than the QUIKLOK Connector.
ANY QUESTIONS REGARDING QUIKLOK CONNECTOR INSTALLATION, PLEASE CALL 1-800-822-2565
2006 A-LOK Products, Inc. Supersedes all previous literature. COVERED BY ISSUED AND/OR PENDING PATENTS

ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com
800-822-2565 215-547-3366 215-547-5260 FAX

8/06

How To Install A Quik-Lok Connector On A Quik-Lok Mandrel


1

INSIDE (CORE)
MANDREL HALF

ORIENT CLAMP TAKE DOWN


MECHANISM/WORM DRIVE
TOWARDS TOP OF MANDREL

QUIK-LOK CONNECTOR
OUTSIDE (JACKET)
MANDREL HALF
CLAMP TAKE DOWN
MECHANISM

MAGNET & HOLDER

THE PARTS
4

INSERT QUIK-LOK CONNECTOR


DOWN IN CORE/WHITE MANDREL HALF

BRUSH FORM RELEASE ON


OUTSIDE OF BOTH
MANDREL HALVES

SNUG DOWN IN PLACE UNTIL


WHITE ALIGNMENT PEGS ARE THROUGH HOLES

PLACE MANDREL WITH


WHITE HALF AGAINST CORE
AND MAGNET HANDLE AT
12 OCLOCK

REMEMBER TO REMOVE BLACK


MAGNET PROTECTIVE COVER

PUT OUTSIDE (BLACK)


MANDREL HALF INSIDE
QUIK-LOK CONNECTOR

QUIK-LOK INSERTED IN
WHITE MANDREL HALF

MAGNET IN UP
POSITION
MAKES THIS
MANDREL READY
FOR CORE MOUNT

10

THE COMPANY WITH CONNECTIONS

REMOVE MAGNET STRIP OUT MANDREL BY USING


DEAD BLOW HAMMER TO HIT WHITE ALIGNMENT PEGS

READY TO SHIP FOLDED INSIDE WALL


CLAMP MECHANISM AT 12 OCLOCK

ALOK PRODUCTS INCORPORATED


P.O. Box 1647 697 Main Street
Tullytown, PA 19007
800-822-2565 215-547-3366
215-547-5260 FAX
www.a-lok.com email: info@a-lok.com

The Company With Connections


ON SITE WASTEWATER

SEPTIC TANK CONNECTORS


ALOK SEPTIC TANK CONNECTORS
Z-LOK C104-4
CONNECTOR

X-CEL 9091
CONNECTOR

X-CEL ON MANDREL
ATTACHED TO FORM

KEY ADVANTAGES

CAST IN
CONNECTOR CLAMPED
DOWN ON PIPE TO
CREATE WATERTIGHT
CONNECTION

CONNECTOR ROLLED
BACK ON MANDREL
ATTACHED TO FORM

Let ALOK Products, the recognized leader in


the manufacturer of watertight connectors, show
you profitable, cost-effective septic connectors
that work!

Simple and easy to use


Cost-effective
Compatible with wet and dry applications
One-piece hole former

PRODUCT REFERENCES

PART 6 DIMENSIONAL DATA


PIPE
9091 X-CEL C104-4 ZLOK
1.5" Schedule 40
X
2.0" Schedule 40
X
4.0" Schedule 40
X
X
4.0" SDR 35
X
X

MEETS OR EXCEEDS REQUIREMENTS OF ASTM C-923

ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@alok.com
800-822-2565 215-547-3366 215-547-5260 FAX

The Company With Connections

TM

CORROSION PROTECTION FOR CONCRETE STRUCTURES

DURA PLATE 100 LINER SYSTEM


ALOK DURA PLATE 100 LINER SYSTEM
The Duraplate 100 Liner
is a corrosion protection
system for concrete
structures used in
wastewater, stormwater
and light industrial
applications. It is an
extremely durable as well
as resilient PVC polymer
blend material that is
thermoformed into a
sectional design. The
compression joints allow
for secure installation of
the sections during the
Precast process and
eliminate the need for welding.

MATERIAL
The liner and seals are all formed from materials selected for their
chemical resistance properties. The main panel sections are formed
from a polymer blend, while the vertical panel joints are sealed with
an EPDM rubber, and the horizontal structure joints with an approved
preformed butyl sealant.

KEY ADVANTAGES
The Dura Plate 100 Liner System was designed on a three point
design philosophy.
1)

2)

3)

The system will provide corrosion protection to the concrete


substrate, by shielding it with a protective barrier of inert
material embedded to the inside wall of the structure. Each
panel features a minimum return on each edge to ensure
proper sealing.
The design will minimize the freight cost by using a sectional
design that will allow the pieces to be nested within each other
while being shipped to the precaster.
The design will provide easy installation without the need for
welding sections together, but still providing complete corrosion
protection to the structure.

PERFORMANCE STANDARD
The Dura Plate 100 Liner meets or exceeds all material and test
requirements as outlined by the manufacturer.
Chemical Resistant:
Chemical
Sulfuric Acid (H2SO4)
Sodium Hydroxide (NaOH)
Ammonium Hydroxide (NH3OH)
Nitric Acid (HNO3)
Ferric Chloride (FeCl3)
Soap
Detergent

Solution
20%
5%
5%
1%
1%
0.10%
0.10%

Physical Properties of Liner Panel:


Test
ASTM
Method
Tensile
D-638
Elongation
D-638
Tensile Modulus
D-638
Flexural Strength
D-790
Flexural Modulus
D-790
Tensile Impact
D-1822

Minimum
Value
6,100 psi
28.5 %
325,000 psi
9,200 psi
340,000 psi
640 in-lbf

PRODUCT SPECIFICATIONS
A protective liner shall be used whenever a precast concrete manhole or
structure is used in a sanitary or light industrial sewer system in which the
potential for corrosive attack to the concrete substrate exists.
The liner shall be the Dura Plate 100 Liner as manufactured by A-LOK
Products, Inc., Tullytown, PA or approved equal.
The design of the liner shall provide a corrosion protective barrier permanently
embedded to the inside wall of the structure. The liner system shall assure
that:
1) The liner shall become an integrally part of the structure wall by casting
the liner with the structure during the manufacturing process. The liner
shall also be capable of being cast into a round structure by curving the
liner in a manner that allows it to remain permanently attached to the
inside structure wall.
2) Vertical joints between the liner sections shall be made by the mechanical
compression of a EPDM rubber strip between the returns of the two
panels with self tapping screws spaced every 3 inches apart.
3) Horizontal joints between structure sections shall be sealed with an
approved butyl strip compressed between the sections in a manner as
recommended by the manufacturer.
4) The liner system shall be composed from materials that are corrosion
resistant by nature and conforms to the physical and chemical
requirements as determined by the manufacturer.
5) The liner shall be sized specifically for the type of structure being used
and shall be installed in accordance with the recommendations of the
manufacturer.

PRECAST INSTALLATION INSTRUCTIONS

1. Inspect core for sharp or jagged edges that could damage the liner
during the shipping process.
2. Place Dura Plate 100 Liner panels level around the core of the form.
Form release agent is not necessary.
3. Install the vertical joints by placing the black rubber strip between the
panel returns, making sure that the flap of the strip is fitted over one of
the returns.
4. Place backing plate on the inside return of panel that the flap fits over.
Hold together with spring loaded clamps evenly spaced about 12"
apart.
5. Secure the panels together with fasteners placed every 3 inches,
making sure that each fastener is tightened to 5 in-lbs.
Note: The fasteners must be installed from the side opposite the flap,
straight thru the backing plate, parallel to the liner.
6. Repeat for all seams.
Note: Caulk can be placed between the form core and liner returns to
minimize concrete seepage during production.
7. Install reinforcement into form with any other necessary parts needed
for the structure.
8. Pour concrete around the liner evenly to prevent shifting of the liner.
9. Vibrate and compact the concrete in a manner that will protect the liner
and produce a dense, homogenous structure.
10. Take precaution to protect the liner from sharp or jagged objects while
stripping from the form.
11. Visually inspect the liner after production for any cuts or tears. If repairs
are needed, refer to Dura Plate 100 Liner repair bulletin for proper
repair procedures.
12. If steps or ladders are to be installed, drill all holes in liner larger than
the diameter of the step. Install steps or ladder then caulk area around
step and liner with FR500 caulking material (Lap Sealant).
13. Protect all hole opening surfaces with a minimum 1/8 inch coverage of
Sewer Guard that overlaps the liner at least a 1 inches.

12

JOB SITE INSTALLATION INSTRUCTIONS


1. When unloading the structure be careful. Take measures to protect the
liner from being damaged by rocks or other debris. Lift carefully, do not
drag.
2. Clean and install butyl strips around the joint design making sure that
the butyl overlaps both the cement and liner return.
3. Carefully seat each section together making sure enough pressure is
applied to seal the joint.
4. After structure is in place, plug all lift pin inserts and holes with suitable
non-shrink grout.
5. If any damage to the liner occurs at the job site, use Dura Plate 100
Liner repair bulletin for proper repair procedures.

13

WARRANTY

A-LOK Products, Inc. warrants that the product described in this bulletin meets or
exceeds all material, quality, and workmanship standards suitable for its intended use.
A-LOK Products, Inc. liability is limited to replacement or repair of defective parts
excluding cost of removal, installation or unauthorized repairs. A-LOK Products, Inc.
will not be responsible for incidental or consequential damages or for products which
have been altered or modified. No representative of the company, or any other person,
has the authority to waive, alter or add to this guarantee or to assume for the company
any obligation with the sale or installation of A-LOK Products, Inc. This warranty is in
lieu of all other warranties, expressed or implied.

ANY QUESTIONS REGARDING ALOK DURA PLATE 100 LINER


SYSTEM INSTALLATION, PLEASE CALL 1-800-822-2565

ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com
800-822-2565 215-547-3366 215-547-5260 FAX

DURA PLATE 100 LINER


CORROSION RESISTANT SYSTEM
moforming to the contour of the structure
and shall maintain a minimum wall thickness of .065 inches.
2.3 Rubber Joint Composition The fabricated liner panels shall be joined
together by a slotted strip of EPDM rubber according to the manufacturers specification as illustrated in Figure 1A.

Chemical Resistant:
Chemical
Solution
Sulfuric Acid (H2SO4)
20%
Sodium Hydroxide (NaOH)
5%
Ammonium Hydroxide (NH3OH)
5%
Nitric Acid (HNO3)
1%
Ferric Chloride (FeC13)
1%
Soap
0.10%
Detergent
0.10%
Physical Properties of Liner Panel:
ASTM
Minimum
Test
Method Value
Tensile
D-638
6,100 psi
Elongation
D-638
28.5%
Tensile Modulus
D-638
325,000 psi
Flexural Strength D-790
9,200 psi
Flexural Modulus D-790
340,000 psi
Tensile Impact
D-1822 640 in-lb

Part 1. The Dura Plate 100 Liner


System
The objective of this specification is to
cover the supply and installation of a vacuum formed semi-rigid liner for use in
wastewater and light industrial concrete
structures to effectively shield the interior
of the structure from corrosion.

3.1.2 Antifungal and Antibacterial


Properties - Dura Plate 100 Liner shall be
made from Acrylic PVC Alloy sheets that
resist bacteriological and fungal development. Sheet shall not readily provide a
source of nutrients for bacteria and fungi.
Plasticizers that allow a source of nutrients which support microbial growth for
bacterial or fungal growth shall not be
permitted.

The design of the liner system shall insure


that it will conform to the contour of the
structure and form a permanent mechanical bond to the concrete through use of
preformed horizontal ribs and dovetails.
The liner will be formed in such a manner
that the joints between the structure sections will be afforded protection through
the use of a continuous PVC return into
the joint for a minimum of .50 of an inch.
Provisions will be made to allow the pipe
penetrations to be sealed by applying a
cementitious corrosion resistant material
to the unlined exposed areas within the
openings.

2.4 Butyl Joint Composition Sections of lined concrete structures shall


be joined together by an approved butyl
strip (A-LOK Products, Inc. Tullytown,
PA. MT-329) designed to produce sufficient squeeze-out between PVC returns.

Part 2. Material

Part 3. Physical Properties

2.1 Liner shall be Dura Plate 100


as manufactured by A-LOK Products,
Incorporated, Tullytown, Pennsylvania.

3.1 General - All materials shall


meet the physical and chemical resistant
properties specified in the following
appropriate section.

Organism
ATCC
Aspergillus niger
Penicillium pinophilum
Gliocladium virans
Aureobasidum pullulans
Chaetomium globosum

3.1.1 Physical Properties - All semirigid liner sheets, joint assembly components, corner and weld strips shall have
the following properties when tested at 77
degrees +/- 5 degrees Fahrenheit.

The spore suspensions were


combined and sprayed on the samples and
controls which were placed on mineral
salts agar and placed in the test chamber.

2.2 Liner Composition - The liner,


channel joints, H-joints and corner joints
shall be manufactured from an Acrylic
PVC Alloy.
All sheet compound will result
in a semi-rigid material suitable for ther-

Figure 1A - Panel Joint Detail

Note: All EPDM and Butyl joint compound shall be formulated to meet the
chemical resistant properties of Section
3.1.1.

Sheet shall be subjected to fungus resistance testing in accordance with


ASTM G-21 and bacteria resistance testing in accordance with ASTM G-22,
Procedure B.
Fungus Resistance Testing,
ASTM G-21: Eighteen day cultures of
the following pure culture fungi were harvested, washed and their spore counts
adjusted to 1,000.000 (200,000 per ml).
Number
9642
11797
9645
15233
6205

The samples, along with controls were


incubated for 28 days and examined
weekly.
Sample
Observations
Designation
(Rating*)
Thermoplastic
7
14
21
28
Sheet:
Days Days Days Days
#1
0
0
0
0
#2
0
0
0
0
#3
0
0
0
0
#4
0
0
0
0
Controls:
Filter Paper
4
4
4
4
Glass Slides
0
0
0
0
*Rating: 0=no growth. 1=traces,
2=light, 3=moderate, 4=heavy growth
Bacteria Resistance Testing,
ASTM G-22: Conclusion of Fungus
Resistance Testing: The sheet samples
did not allow any fungus growth (rating
of 0).
A twenty-four hour culture of
Pseudomonas aeruginosa (ATCC 13388)
was harvested and washed three times by
centrifugation using sterile distilled water.
The bacterial suspension was added to
sterile, melted minerals salts agar, mixed
and plates poured. A sample of the inoculated agar was taken and a plate count to
determine the number of viable
pseudomonas present.
Sample
Observations
Designation
(Rating*)
Thermoplastic
7
14
21
Sheet:
Days Days Days
#1
0
0
0
#2
0
0
0
#3
0
0
0
#4
0
0
0
Controls:
Inoculated Agar
0
0
0
Glass Slides
0
0
0
Plate Count Agar 1
1
1
*Rating: 0=no growth, 1=growth
Conclusion
of
Bacteria
Resistance Testing: The sheet samples
did not allow any bacterial growth (rating
of 0).

Part 4. Details and Dimensions of


Standard Liner
4.1 Liner panels shall have a minimum thickness of .065 inches. A combination of standing ribs and mechanical
dovetails shall be used to secure the liner
panels to the wall of the structure and
shall be spaced a maximum of 6.0 inches
apart.
4.2 Liner panels with a combination of standing ribs and dovetails in
diameters of 48" through 60" shall be at
least .50 inches high. Panels of 72" diameter and above shall be at least .75 inches
high.
4.3 Liner with locking extensions
shall be able to withstand a test pull of 100
pounds per linear inch applied perpendicular to the concrete surface for a period
of 60 seconds. No rupture of the locking
extensions or withdrawal from embedment shall be acceptable. This test shall be
made at a temperature between 70 and 80
degrees Fahrenheit inclusive.
4.4 Liner panels shall be formed to
the correct radius to assure a true diameter
match between joined precast sections
when assembled.
4.5 Liner panels shall be formed
with a continuous return into the joint for
a minimum of .50 of a inch which shall
afford protection between the lined precast sections.
4.6 All radius panels shall be vacuum tested for pinholes during the molding process and shall withstand a minimum of 25 inches of mercury for a period
of 60 seconds.
4.7 Panel sections shall be custom
formed to a specified height not to exceed
6' in overall length. Lengths specified
shall include a tolerance ratio of +/- .0625
per foot.

5.3 The liner panels when assembled shall form a circular cylinder that fits
snugly against the inner steel core of the
form. A removable extruded rubber profile or suitable one-sided tape can be used
to seal the liner against the core to prevent
concrete fines from washing down
between the liner and steel core.
5.4 Concrete poured around the
liner shall be distributed evenly to prevent
shifting of the liner.
5.5 Concrete poured against the
liner shall be vibrated, or compacted in a
manner to protect the liner and produce a
dense homogenous concrete to securely
anchor the assembly to the exposed surfaces on the interior of the structure.
5.6 When extracting the steel core,
care should be taken to protect the liner
from damage. Instruments with sharp or
jagged edges should not be used to release
the forms from the liner.
5.7 Visual inspection of the liner
shall be made after demolding and any
cuts or tears shall be repaired by following the manufacturers repair recommendations.
5.8 The concrete producer shall
take all necessary measures to prevent
damage due to casting, demolding, and
delivery of the lined concrete structure.

Part 6. Field Installation of Lining


6.1 General - Field installation of
all lined precast sections shall be done in
accordance with the recommendations of
the manufacturer.
6.2 The horizontal joints between
sections of lined concrete structures can
be made by either butyl or a combination
of butyl and rubber joint per the recommendation of the concrete manufacturer.
(See Fig. 2)

Part 5. Plant Installation of Liner


5.1 General - Installation of all lining shall be done in accordance with the
manufacturers recommendations.
5.2 Lining coverage shall not be
less than the minimum shown on the
approved shop drawings or construction
plans.
2

Figure 2 - Butyl Joint

6.3 Joint surfaces must be clean to


ensure proper adhesion of the butyl. An
application of a butyl based primer will
produce the highest degree of adhesion to
the joint surfaces.

6.7 The installing contractor shall


take all necessary measures to prevent
damage to the liner due to material handling, installation, or equipment or material used in installing, or used in or taken
through the structure.

Part 7. Testing and Inspection


7.1 General - This section covers
the in-plant and field inspection and testing method of lined concrete sections.
7.2 The liner manufacturer shall
test each panel to withstand a constant
vacuum of 25 inches of mercury for a
period of 60 seconds. Any sections failing
to meet this requirement shall be rejected.

Figure 2A - Spigot Up Joint Detail


6.4 Place specified butyl material
as indicated in Figures 2A and 3A. Butt
ends of material together. Material should
never be overlapped. Butyl material shall
be an approved strip per Section 2.4.

Figure 4A - Drilled Hole Detail for


Steps or Ladders

7.3 In-plant inspections of panels


cast into concrete sections shall be visually inspected for cuts or tears and shall be
repaired following the manufacturers recommendations.

Part 8. Liner Appurtenances


8.1

Figure 5

Steps or Ladders

8.1.1 Steps shall be attached by


either casting a preformed polypropylene
insert to accept a polypropylene drive in
step (Fig. 4), or by casting or drilling a
precise hole to accept a polypropylene
press fit step (Fig. 4A), as per the recommendations of the step manufacturer.
8.1.2 After installation of either the
steps or ladders, the junction point of the
device and the liner shall be sealed by
applying an approved butyl caulking
material (A-LOK Products, Inc.,
Tullytown, Pennsylvania, Lap Sealant).

8.2

Hole Liners

8.2.1 Pipe penetrations through the


lined wall shall be afforded protection by
applying .125 inch trowelable, chemical
and corrosion resistant epoxy mortar to
the unlined exposed areas within the
openings and shall overlap the liner wall a
minimum of 1.50 inches as illustrated in
Figure 5A.

Epoxy Liner
Protection Of
Hole Opening.

Figure 3A - Bell Up Joint Detail


6.5 Lined sections should be carefully centered and lowered to complete
coupling process. Apply sufficient pressure to properly seat joint and achieve
squeeze out.
6.6 After structure is in place, care
should be taken to properly plug all lift
pin inserts or holes with a suitable nonshrink grout.

Figure 5A - Hole Liner Detail


8.3

Figure 4 - Casting in Polypropylene


Step Insert
3

Grade Work Protection

8.3.1 Corrosion protection between


the lined concrete structure and the cast
iron frame and cover shall be obtained
through the use of a telescoping Liner
System (A-LOK Products, Inc.,

Tullytown, Pennsylvania, Water-LOK


Connector) illustrated in Figure 6A below.

Dura Plate Liner


Slab Top

Figure 6A - Water-LOK Components


and Duraplate Slab Top Liner
8.3.2
Corrosion protection
shall be afforded for aluminum entry
frames and doors by fabricating a semirigid riser to match the inside dimensions
of the access frame.

(2)

The liner shall be manufactured


from an acrylic modified PVC alloy.

(3)

The liner shall be thermo-vacuum


formed to create a semi-rigid liner.

(4)

The liner shall conform to the interior diameter of the structure.

(5)

The liner shall be formed with dovetail ribs so that it is securely


anchored to the concrete structure.

(6)

The liner shall be formed with


returns into the bell and spigot joints
to allow for butyl sealant to be
placed and to eliminate the need for
any field welding of the joint.

(7)

The liner shall be light in color to


reflect light.

(8)

The liner shall have both antifungal


and antibacterial properties that will
not readily provide a source of nutrients for bacteria or fungi.

A-LOK Products, Inc. Standard


Terms and Conditions of Sale apply to
purchase of this product.

(9)

The liner shall be a minimum of


.065" thick.

All information is subjected to


change without notice.

(10) The liner panels shall be joined


together by an EPDM slotted rubber
strip.

Part 10. Specifications of Manhole


Coatings and Linings

(11) All materials shall meet the physical


and chemical properties specified in
the appropriate ASTM specification.

Part 9. Warranty
A-LOK Products, Incorporated
warrants that the product described in this
bulletin meets that material, quality, and
workmanship conformable to the recommended use.
A-LOK Products, Incorporated liability is limited to replacement or repair of
defective parts, excluding cost of
removal, installation or unauthorized
repairs. A-LOK Products will not be
responsible for incidental or consequential damages or for products which have
been altered or modified. No representative of the company, or any other person,
has the authority to waive, alter or add to
this guarantee or to assume for the company any obligation or liability in connection with the sale or installation of ALOK Products, Inc. products. This warranty is in lieu of all other warranties,
express or implied.

Interior Lining
(1)
Figure 7A - Duraplate Slab Top
With Opening

The concrete structure shall have a


liner that is integrally cast with the
precast section, at the time of manufacture.

(12) The liner shall be Dura Plate 100 as


manufactured by A-LOK Products,
Incorporated. Tullytown, PA, or
approved equal.

Copyright 2007 A-LOK Products, Incorporated


US Patents 4,751,799 and 5,081,802
Canadian Patents 1,285,501 and 2,030,017
Other Patents Pending

THE COMPANY WITH CONNECTIONS

P.O. Box 1647 697 Main Street Tullytown, PA 19007


800-822-2565 215-547-3366 215-547-5260 FAX
www.a-lok.com email: info@a-lok.com
4

WATERLOK

TM

GRADE WORK PROTECTION SYSTEM


Inflow & Infiltration (I&I) deterioration
of grade work is one of the leading
causes of pothole formation around
manholes. Grade work is constantly
being attacked by the pounding and
vibration of traffic, the corrosive effect
of chemicals produced by bacteria
found in sewer systems, and the
freeze/thaw cycle. These forces destroy
the grade work by creating voids that
eventually turn into potholes.
Pr otect your
WATERLOK.

grade

wor k

with

IS YOUR
GRADE WORK
PROTECTED?

The Problem With


Unprotected Grade Work.

WATERLOK is a telescopic liner


system that protects the grade work
area from water infiltration as well as
chemical attack. The self adjustability
of the system allows it to compensate
for grade movement after installation.
WaterLOK can be used in both new and
rehabilitation projects and is
compatible with all mechanical means
for securing castings to structures.

BRING YOUR GRADE WORK UP


TO GRADE WITH WATERLOK

The Solution is
WATERLOK!

697 Main Street P.O. Box 1647 Tullytown, PA 19007


800-822-2565 215-547-3366 215-547-5260 Fax

http://www.a-lok.com e-mail info@a-lok.com

38

WATERLOK

TM
BUTYL

CASTING

UPPER
WATERLOK

Durability
Made from materials highly resistant to a sewer systems
corrosive environment.

GRADE
RINGS

Adjustability
Telescopic design allows up to 14 of vertical movement along
with enough deflection to accommodate changes in grade, or
road height due to re-paving.

O-RINGS

Reliability
High quality O-rings and butyl create a permanent watertight
seal without the need for mechanical parts or tools.
Can not be accidentally dislodged while entering or exiting
structure.

Compatibility

LOWER
WATERLOK

Use with the Dura Plate 100 Liner system for total structural
corrosion protection.

BUTYL

Availability

STRUCTURE

Available for 24, 27 and 30 structure openings

Testability

WATERLOK
COMPONENTS

When vacuum testing is required expandable steel bands are


available to hold O-Rings in place and retain the shape of the
Upper and Lower Water-Lok Parts.

0.00
TO
7.00

6.00
TO
14.00

DIMENSIONAL
ADJUSTMENT

Upper
WATERLOK

Lower
WATERLOK

Butyl

Lube
O-ring
Instructions

WATERLOK Installation Kit


Every WATERLOK connector is shipped boxed with everything needed for installation.
Instructions, O-rings, Lube, Butyl and Connectors.

Dura-Plate 100 Epoxy Mortar


QUESTIONS OR TO ORDER CONTACT:

ALOK PRODUCTS INC. 697 MAIN STREET TULLYTOWN, PA. 215-547-3366 OR 1-800-822-2565
TECHNICAL DATA SHEET
Description:
Dura-Plate 100 Epoxy Mortar provides concrete and
masonry surfaces with increased chemical and abrasion
resistance. The three-part, resin aggregate system forms
a trowelable epoxy mortar that applies easily to overhead
and vertical concrete surfaces.
When cured, Dura-Plate 100 Epoxy Mortar forms a high
strength protective coating for sanitary sewer lift stations,
manholes, and other structures. It is impermeable to
water, and resistant to attack by hydrogen sulfide and acid
generated by microbiological sources.
Product Benefits:

Easy application requires no primer

Non-sagging mortar for vertical and overhead

Technical Data:
Dura-Plate 100 Epoxy Mortar cures to form a solid, durable seal.

application

Property

Excellent concrete adhesion, both at application,


and after curing

Provides waterproof barrier

Excellent resistance to hydrogen sulfide and


sulfuric acid

100% solid, no VOC

4 hrs.
7 days
14 days
165F
45F

Dura-Plate 100 Epoxy Mortar was tested for chemical resistance by


immersing cured samples in 20% sulfuric acid at 70F for 112 days.

Chemcial
20% sulfuric acid 112 days immersion

5 gallon pail kit (25 ft at 1/8 thickness) containing:

Value
Resistant*

*No changes in mass or apperance of test specimen after immersion.

Resin Part A: 1 gallon can


Hardener Part B: gallon can
Filler Part C: 20 lb.
Sika Color Pack

3 gallon pail kit (12.5 ft at 1/8 thickness) containing:

2 hr. @ 70 F
< 100 F

Chemical Resistance:

Packaging & Coverage:

Value

Pot Life
Peak Exotherm @ 70 F
Cure time @ 70 F
Initial set
90% strength
Final strength
Maximum Service Temperature
Minimum Application Temperature

Resin Part A: gallon can


Hardener Part B: gallon can
Filler Part C: 10 lb
Sika Color Pack

Component Physical Properties:


Dura-Plate 100 Epoxy Mortar is a 3-part thixotropic system packaged
in a pail kit with a Sika Color Pack.

Property

Resin Part A

Hardener Part B

Color
Form
Odor
Specific Gravity
(water = 1)

White
Paste 100,000 cps
No Odor

Tan
Liquid 20,000 cps
Slight ammonia

1.2

1.05

Part C is a especially formulated silica filler.

Safety:
Dura-Plate 100 Epoxy Mortar has a low level of toxicity.
Good industrial hygiene practice and appropriate
precautions should be employed during use. Avoid
personal contact with the product. See MSDS for specific
details.
Storage and Handling:
Keep cans tightly closed in a cool, dark, dry location. All
cans should be disposed of in an environmentally safe
manner and in accordance with governmental regulations.
Unopened product has a shelf life of two years.

Application:
Surface Preparation: Surfaces should be clean,
structurally sound, and fully cured for 28 days.
Remove any loose material. Be sure that surfaces
are free of oil, grease, paint, rust, asphalt, and other
contaminants. Surfaces may be cleaned with
detergents followed by thorough rinsing with water.
Best results are seen when new concrete is abraded
by abrasive blast, high-pressure water blast, or acid
etch to obtain uniform surface texture. Dura-Plate
100 Epoxy Mortar may be applied to clean surfaces
that are dry or are slightly damp.

Mixing: Dura-Plate 100 Epoxy Mortar is packaged in


factory pre-measured kits. To mix, pour the Resin
Part A and the Hardener Part B into a clean pail. Mix
thoroughly until a consistent color is seen. Slowly
add in Filler Part C, continuing to mix until the
consistency is uniform. Mix only complete batches.
Add the light gray Sika color pack slowly till it is
thoroughly mixed and uniform color is seen. Do not
add solvents to Dura-Plate 100 Epoxy Mortar.

Installation: Apply 1/8 (3 mm) in thickness with a


trowel or spatula. Apply Dura-Plate 100 Epoxy
Mortar at ambient temperatures of 45F (7C) and
above. Do not apply once the material has begun to
set up. Pot life and cure time of Dura-Plate 100 are
dependent on temperature. Higher temperatures
shorten these times. Lower temperatures lengthen
these times.

Clean Up: Clean uncured material from equipment


with Grime-Away Multi-Purpose Cleaning Wipes or
Type HP Cleaner. Remove cured material
mechanically. Clean hands with soap and water or
Grime-Away Multi-Purpose Cleaning Wipes.

Copyright 2010. American Polywater Corporation. All Rights Reserved


Important Notice: The statements and information here are made in good faith based on tests and observations we believe to be reliable. However, the completeness and accuracy of the information is not guaranteed.
Before using, the end-user should conduct whatever evaluations are necessary to determine that the product is suitable for the intended use. The user assumes all risks and liability in connection with such use.
The statements contained herein are made in lieu of all warranties, express or implied, including, but not limited to, implied warranties of merchantability and fitness for a particular purpose, which warranties are hereby
expressly disclaimed. American Polywater's only obligation shall be to replace such quantity of the product proven to be defective. Except for the replacement remedy, American Polywater shall not be liable for any loss,
injury or damage, direct or indirect, arising from the use or the failure to properly use these products, regardless of the legal theory asserted. The foregoing may not be altered except by a written agreement by the officers of
American Polywater Corporation.

Lit-EM Tech/07-10

MANUFACTURED BY:

DISTRIBUTED BY:

WWW.A-LOK.COM

BUTYL
BUTYL SEALANT
SEALANT SYSTEMS
SYSTEMS

BUTYL-LOK

ADHESIVE-PRIMER SYSTEMS
Water Emulsion Type (non-flammable)
Solvent Type (flammable)

PLASTIC

PREFORMED TAPES

RUBBER

STANDARD SIZE IN STOCK


(Custom sizes available)

BUTYL-LOK WRAP

CARTRIDGES

TROWELABLE-PUMPABLE
GRADE

ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com
800-822-2565 215-547-3366 215-547-5260 FAX

GENERAL PRODUCT DESCRIPTION


BUTYL-LOK sealant systems are customed engineered and
manufactured to comply with current standards and
specifications required by the Federal, State and local
regulatory agencies for use by the precast concrete industry
and its contractors.
BUTYL-LOK sealants are supplied in ready-to-apply forms for
all weather installations and conditions. Specific applications
are:
SANITARY AND STORM SEWER MANHOLES
PIPE (Round, Oval, Flatbase, Elliptical and Arch types)
BOX CULVERTS
UTILITY VAULTS
BURIAL VAULTS
SEPTIC TANKS AND SEWAGE TREATMENT PLANTS
WET WELLS
PRECAST CONCRETE WALL PANEL SYSTEMS

PRODUCT REFERENCES
BUTYL-LOK meets or exceeds all basic requirements of
Federal Specification *SS-S-21 0-A
*AASHTO M-198 and ASTM C-990.
*NOTE: Meets all aspects with exception of flash point and fire point.

CHEMICAL COMPOSITION

Butyl Rubber-Hydrocarbon
(% by wt.)
Inert Mineral Filler
(% by wt.)
Volatile Matter (% by wt.)

TEST
METHOD

REQUIREMENTS

BUTYL-LOK

ASTM D-297

50-70

58%

SS-S-210-A
ASTM D-6

30-50
2.0 Max.

42.0%
1.0%

*NOTE: Contains no asbestos fibers or asphaltics.

PHYSICAL PROPERTIES
KEY ADVANTAGES
BUTYL-LOK sealants remain permanently flexible and form
permanent bonds to a wide variety of substrates including
concrete, metals and plastics. These products are designed
not to shrink or oxidize and have excellent resistance to
environmental temperature extremes, acid and alkaline
conditions. Adhesion and cohesion actually improves after
joint has been formed and placed in service.

SURFACE PREPARATION
Joint surfaces should be clean and dry. Due to the high
adhesive quality of BUTYL-LOK, priming of the joint surfaces
is not normally required. However, should wet or unusual
application conditions exist, it is recommended that either
BUTYL-LOK Emulsion (non-flam) or Solvent (flammable)
Adhesive Primer be coated on the joint surface and allowed to
dry a minimum of 10 minutes before application of joint
sealant.

APPLICATION
BUTYL-LOK bonds instantly to joint surfaces and to itself.
Always butt ends of preformed sealant together never
overlap. Leave protective release paper on sealant during
application and remove only after structure is ready for
coupling. The joint should them be coupled with sufficient
pressure for proper joint completion. The resulting annular
space after structure is properly coupled, determines the
volume (cross-section size) of BUTYL-LOK required.

Specific Gravity @ 77F.


Ductility @ 77F.
Cone Penetration @ 77F.
Flash Point C.O.C. (F.)
Accelerated Aging
(Mechanical Oven 4 hours @ 212F.)

TEST
METHOD
ASTM D-71
ASTM D-113
ASTM D-217
ASTM D-92

REQUIREMENTS
1.15-1.50
5.0 Min.
50-100
350 Min.

UV Resistance (Direct FL
Exposure - 365 days)
Elongation Initial @ 77F.
Two Weeks @ 195F.
Two Weeks - Total
Water Immersion
Flow Resistance (1" wide
overhead joint exposed
to 135F. for 7 days)
Storage Life
Application Temp. Range
Service Temp. Range

BUTYL-LOK
1.25-1.35
6.0 CM
55-80
375
Maintained
99+% Solids
(Flexibility not
affected)
No Visible
Damage
300% Min.
300% Min.
300% Min.
No Flow
Indefinite
0 to 120F.
-40 to 250F.

CHEMICAL RESISTANCE
(Total Immersion 112 Days)
Sulfuric Acid
Sodium Hydroxide
Ammonium Hydroxide
Nitric Acid
Ferric Chloride
Soap
Detergent
(linear alkyl bensyl sulfonate)

REQUIREMENTS
20%
5%
5%
1%
1%
0.1%

BUTYL-LOK
No Visible Damage
No Visible Damage
No Visible Damage
No Visible Damage
No Visible Damage
No Visible Damage

0.1%

No Visible Damage

BUTYL-LOK SEALANT SYSTEMS


PREFORMED TAPES
PRODUCT
NO.
FS-3050
FS-3075
FS-3100
FS-3125
FS-3150
FS-3200

DIA.
EQUIVALENT
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"

CROSS SECTION
SIZE
.45" x .45"
.675" x .675"
.89" x .89"
1.0" x 1.123"
1.187" x 1.5"
1.875" x 1.675"

ROLL
LENGTH
21.75'
14.5'
14.5'
14.5'
10.75'
7.50'

ROLLS PER
CARTON
12
8
6
5
4
4

FEET PER
CARTON
261
116
87
72.5
43
28

CARTON
WEIGHT
35 lbs.
33 lbs.
42 lbs.
55 lbs.
47 lbs.
52 lbs.

CARTONS PER
PALLET*
40
40
40
40
40
40

14'6"
14'6"
14'6"
14'6"

4
2
2
2

58
29
29
29

28 lbs.
30.3 lbs.
38.2 lbs.
45.5 lbs.

45
40
40
40

DURA-PLATE BUTYL-LOK SEALANT


MT-320
MT-329
MT-329-A
MT-329-B

1/2"
3/8"
5/8"
3/4"

x
x
x
x

1-1/2"
4-1/2"
3-1/2"
3-1/2"

FR 500 DURA-PLATE LAP SEALANT 1/10 Gallon Cartridges


CT-0335 LAP SEALANT-LS600 (WHITE) 1/10 Gallon Cartridges Packaged 10 tubes/case 120 cases/pallet
*Note: All pallets shrink wrapped suitable for outside storage.
Custom sizes available upon request Call us with your special requirements.
BK-0069
R-900
CN-0189

TROWELABLE PUMPABLE GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Available in 5 gallon pails


1/10 Gallon CARTRIDGES (BLACK) . . . . . . . . . . . . . . . . . . . . . Packaged 10 tubes/case 120 cases/pallet
ADHESIVE-PRIMER: SOLVENT TYPE (flammable) . . . . . . . . . . . . . . . . . . . . . . . 1 Gallon pails 6 per case
(9% WASH)

HORIZONTAL JOINTS
PIPE
SIZE
(ID)
12"
15"
18"
21"
24"
27"
30"
33"
36"
39"
42"
45"
48"
54"
60"
66"
72"
78"
84"
90"
96"
102"
108"

RECOMMENDED SIZES
1/64" TO
5/16" TO
9/16" TO
1/4**
1/2**
11/16**
1/2"
3/4"
1"
1/2"
3/4"
1"
1/2"
3/4"
1"
1/2"
3/4"
1"
3/4"
1"
1-1/4"
3/4"
1"
1-1/4"
3/4"
1"
1-1/4"
3/4"
1"
1-1/4"
3/4"
1"
1-1/4"
1"
1-1/4"
1-1/4"
1"
1-1/4"
1-1/2"
1"
1-1/4"
1-1/2"
1"
1-1/4"
1-1/2"
1-1/4"
1-1/2"
1-3/4"
1-1/4"
1-1/2"
1-3/4"
1-1/4"
1-1/2"
1-3/4"
1-1/4"
1-1/2"
2"
1-1/4"
1-1/2"
2"
1-1/2"
1-3/4"
2"
1-1/2"
1-3/4"
2"
1-1/2"
1-3/4"
2"
1-1/2"
2"
2"
1-1/2"
2"
2"

VERTICAL JOINTS
ID OF
STRUCTURE
42"
48"
54"
60"
66"
72"
84"
96"

RECOMMENDED SIZES
1/64" TO
5/16" TO 9/16" TO
1/4**
1/2**
11/16**
3/4"
1"
1-1/4"
3/4"
1"
1-1/4"
1"
1"
1-1/2"
1"
1-1/2"
1-1/2"
1"
1-1/2"
1-1/2"
1"
1-1/2"
1-1/2"
1"
1-1/2"
1-3/4"
1"
1-1/2"
1-3/4"

*The annular space of the joint is


calculated by subtracting the
tongue O.D. from the bell I.D. and
dividing by 2.

TYPICAL JOINT
CONFIGURATIONS
VERTICAL INSTALLATION

Bell

Tongue

HORIZONTAL
INSTALLATION
Tongue

Bell

BUTYL-LOK WRAP
BUTYL-LOK WRAP is an extruded Butyl adhesive tape, designed to provide high strength, watertight seals
on properly primed concrete surfaces and joints of any kind. The Butyl compound is soft, tacky and
bonded to either a Plastic backing of an E.P.D.M. Rubber backing. Both kinds of tape are wound in rolls
on a release liner for easy application.

SUGGESTED APPLICATIONS FOR BUTYL-LOK WRAP


Any external concrete joints:
Manhole Joints
Arch Pipe Joints
Round Pipe Joints
Septic Joints
Box Culvert Joints
Burial Vault Joints
Elliptical Pipe Joints
Grade Ring Joints
Concrete Bridge Spans
New construction, repair or rehabilitation
Seals vacuum test leaks
Protective pipe wrap in corrosive conditions

ADVANTAGES OF BUTYL-LOK WRAP

Prevents or stops infiltration


Economical sealing solution
Easy application
Excellent initial adhesion and strength
Withstands constant stress at elevated temperatures
Excellent protection against corrosion
Readily available

AVAILABLE IN THE FOLLOWING SIZES:

BUTYL-LOK WRAP is designed to be used with No. 4 primer, and should not be stretched
during installation.

ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com
800-822-2565 215-547-3366 215-547-5260 FAX

THE COMPANY WITH CONNECTIONS

The Company With Connections


SECONDARY INVERT FORMING SYSTEM

TRU-CONTOUR
TRU-CONTOUR
The Tru-Contour standard system allows for 2/3 invert depth and is
compatible with a variety of flexible pipe to manhole connectors. Full
depth systems are also available.
The Tru-Contour assembly consists of:
1) A hole adapter which is designed to align the invert assembly with
the flexible pipe to manhole connector. This insures pipe to invert
compatibility.
2) A series of 4 wedges and straight sections which when combined
provides an unlimited selection of angles to create enough
flexibility to form an in invert within 1.5 degrees.
3) A stabilizing jack which prevents from floatation during casting
operations. This insures that correct fall is maintained across the
manhole base.

AVAILABILITY CHART
A-LOK Products, Inc. and Tru-Contour have joined forces to bring
together the best in secondary precast inverts available today. The
Tru-Contour Invert Forming System offers the manhole producer a
very durable, systematic and versatile method of forming all invert
configurations from 4" through 48" diameter.

SIZE
(IN/DIA.)
4"
6"
8"
10"

KEY ADVANTAGES
Two, three, and four way configurations including dead end
combinations with a standard .2 ft. of elevation difference (fall) can
be made easy and rapidly without the need for skilled labor.
Greater fall can be obtained based on the operators' ability to
experiment. The system's versatility is due to an unlimited
combination of
four basic wedges. With the combination of one or more of these
wedges, any angle can be obtained within 1.5 degrees. This allows
enough flexibility to effectively form an invert which aligns perfectly
with the entering pipeline.

12"
15"
18"
21"
24"
27"
30"
36"
42"
48"

2-WAY

3-WAY

4-WAY

System also available in Single Piece construction.


The Tru-Contour system cuts costly labor both in set-up and concrete
finishing time. A basic three way can be set up in approximately
fifteen minutes and depending on pouring procedures, can allow an
average of four inverts per day to be formed from a single system.
Finishing time is kept to a minimum due to the accuracy of flows the
forms create. Each invert in regard to channel width, depth and radial
turn is form finished.

Patent #4,484,724

INSTALLATION INSTRUCTIONS

#1 ASSEMBLY STARTS WITH CENTERING


TRIANGLE IN LOW HOLE

#4 POSITION ANTI FLOTATION BAR AND


ADDITIONAL CHANNEL

#2 ASSEMBLE SMALLEST ANGLE WITH


CENTERING ADAPTOR

#5 POSITION HUBS

#3 SMALLEST ANGLE ASSEMBLE IN LOW


HOLE AND UPSTREAM SIDE.

#6 COMPLETED THREE-WAY ASSEMBLY


READY TO POUR

ANY QUESTIONS REGARDING TRU-CONTOUR INSTALLATION, PLEASE CALL 1-800-822-2565

ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com
800-822-2565 215-547-3366 215-547-5260 FAX

The Company With Connections

TM

LIFTING SYSTEM FOR PRECAST STRUCTURES

KEY-LOK
ALOK KEY-LOK

KEY ADVANTAGES
The KEY-LOK LIFT INSERT is designed with a key slot to prevent
rotation in the mold and to provide easy form removal in both wet cast
and dry cast methods of production.
The insert forms a precise cavity to accept the keyed lifting pins. This
assures minimum movement of the lifting device during handling.
The shape of the insert locks the lifting device into the cavity. As lifting
tension is applied, the KEY-LOK Lift Pins rotate 90 for removal.
The KEY-LOK Lift Pin Insert eliminates the necessity of a cold joint in
patching the lift hole allowing immediate backfilling of the structure,
enhancing project quality and safety.
The use of an A-LOK Manhole Lift Bar assures that the Lift Pins stay
perpendicular to the manhole wall while lifting.

PRODUCT REFERENCES
A.) ASTM-C-478
Certified A-LOK lift bar with Choker chains for lifting cones.
The KEY-LOK LIFTING SYSTEM
is designed to provide a safe,
watertight and economical means
of handling precast concrete
structures.
The polypropylene lift pin insert is
installed during the manufac-turing process and becomes an integral part of the structure with a
predetermined thickness of concrete forming a barrier to prevent
infiltration into the structure.
The lift pin and lift bar hardware is designed to provide a safe and
durable means of handling precast concrete structures.

MATERIAL
The KEY-LOK Lift Pin Insert is molded from a copolymer
polypropylene compound.
The Lift Pin and Lift Bar hardware is designed and made to meet
The Code of Federal Regulations: 29 CFR 1926.704(d) and CFR
1926.251(a) (4) for lifting devices. Quality and reliability is
assured through testing each device.

Standard Specification for Precast Reinforced Concrete


Manhole Sections.

B.) FEDERAL REGULATION CODES


29 CFR 1926.704(c) and (d)
29 CFR 1926.251 (a) (4)

PERFORMANCE STANDARD
The A-LOK Lift Pin's working load is in observance of Federal
Regulation codes 29 CFR 1926. 704 (d) and 29 CFR 1926.251
(a) (4).

PART 6 DIMENSIONAL DATA


Listed below are the proof of design testing results:
Wall
Thickness
(Inches)
5
4-1/2
6
3-1/2

Insert
No.
1095
1096
1097
1098

Working
Load/Pin
(lb.)
4500
3400
6500
2000

NOTE: The concrete had a 28 day compressive strength of 4,000


PSI. The U-shaped reinforcement in the following illustration, is
required to obtain the above proof of design.

PRODUCTION INSTRUCTIONS

MANHOLE LIFT INSTRUCTIONS


The ALOK Lift Bar is designed to provide a safe and economical means of handling precast manholes and other concrete structures. As lifting tension is applied, the lift pins rotate
90 degrees in the ALOK Insert to a locked position for safe handling.
ALOK meets OSHA 5:1 safety factor. PLEASE NOTE: Lift Bar, pins and chains should be
vertical with manhole when lifting.

PLACE REINFORCEMENT U-SHAPE


HERE AGAINST INSERT CAM

WIRE TIE UNDER INSERT TO HOLD REBAR IN PLACE

NOTE: PLACEMENT OF INSERT SHOULD BE 1.5" OVER CENTER OF STRUCTURE

WARNING: Serious harm or death may result from safety hazards caused by improper use and installation of this product.
Use of this product in applications other than those stated should first be carefully tested prior to general production use. Testing must accurately represent
intended use, with full consideration to all field conditions and factors of safety. The safe working load of this product should always be observed.
PLEASE NOTE: A LIFT BAR SHOWING ANY SIGNS OF DEFORMATION OR WEAKNESS SHOULD BE DISCARDED.

ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com
800-822-2565 215-547-3366 215-547-5260 FAX

The Company with Connections

TM

TM

for placement of all size Key-LOK Lift Inserts


to specifically accommodate Key-LOK Lift Pins

Key-LOK Lift Insert Holders

TM

Universal Lift Insert Holders


LH-109X-UNIV
Works with all size wet and dry cast inserts
Installed with Key-LOK Washers (shown to the right)
TM

LH-KWASHER
TM

Key-LOK Washer

Coil Style Lift Insert Holders


LH-1095-C, LH-1096-C, LH-1097-C, LH-1098-C
Works with all size wet and dry cast inserts
Installed with Key-LOK Washers (shown to the right)
TM

LH-109X-T-PR (Pull Ring)

Spring-Loaded Lift Pin Holders


LH-1095-T & LH-1096-T (kit)
Works with all size wet and dry cast inserts
Steel collar is welded to jacket

LH-109X-T-C (Steel Collar)

LH-1096-T-S
or
LH-1095-T-S (Tube Holder Shaft)

LH-109X-BR-P (Holding Pin)


TM

Cam-LOK Lift Insert Holders


LH-1095-BR
Cam-LOK Lift Insert Holder and Steel Collar welded to
jacket with centered or offset holding pin with tether
TM

(Steel Collar)
LH-109X-BR-C (center)
or
LH-109X-BR-C-O (offset)

LH-109X-BR-P
(Cam-LOK Lift Insert)

(Lift Insert Holder)


LH-109X-BR-I (center)
or
LH-109X-BR-I-O (offset)

Urethane Lift Insert Holders


LH-1099-U (kit)
Economical method to place Key-LOK Lift Inserts
Requires 3/8 hole
TM

LH-1099-U-P
(Urethane Lift Pin Holder Insert)

LH-1099-U-S
(Installation
Pin T-Bolt)

697 Main Street P.O. Box 1647 Tullytown, PA 19007


Toll Free: 1.800.822.2565 Phone: 1.215.547.3366
Fax: 1.215.547.5260 www.a-lok.com

Lift Insert Capacity

LI-1098B
Dry Cast 3-1/2 Wall

LI-1096B
Dry Cast 4-1/2 Wall

LI-1095A
Wet Cast

LI-1095B
Dry Cast 5 Wall

LI-1097A
Wet Cast

LI-1097B
Dry Cast 6 Wall

LI-1095BR
Cam-LOK Insert
Dry Cast 5 Wall

STANDARD
REINFORCEMENT

PIGTAIL
REINFORCEMENT

U-SHAPE
REINFORCEMENT

1,200

2,000

2,000

POUNDS

POUNDS

POUNDS

2,000

3,400

3,700

POUNDS

POUNDS

POUNDS

3,000

4,500

4,700

POUNDS

POUNDS

POUNDS

3,600
POUNDS

6,500
POUNDS

6,600
POUNDS

3,000

4,500

4,700

POUNDS

POUNDS

POUNDS

TECHNICAL DATA SHEET

UNIVERSAL MANHOLE LIFT BAR (LB-456)


The A-LOK Universal Lift Bar is designed to provide a safe and economical means of handling 48, 60 and 72
diameter precast manholes and other concrete structures.
Safety, quality and reliability is assured through testing each device. The A-LOK Universal Lift Bar meets OSHA
5:1 safety factor.
PLEASE NOTE: Liftbar hooks and chains should be vertical with manhole when lifting.

Adjustable Shackles
with Screw Pin to
accomodate 48, 60
and 72 Manholes

Identification Tag

3/4 Hammer-LOK
with Safety Latch

0.5 Spectrum 8 Chain

Sling Hook
with Safety Latch

NOTE: Lift bar working load observing


Code of Federal Regulations
29 CFR 1926.704 (d)
29 CFR 1926.251 (a)(4)

WARNING
Serious harm or death may result from safety hazards caused by improper use or installation of this product.
Use of this product in applications other than those stated should be first carefully tested prior to general
production use. Testing must accurately represent intended use, with full consideration to all field conditions
and factors of safety. The safe working load of this product should always be observed.
PLEASE NOTE: A LIFT BAR SHOWING ANY SIGN OF DEFORMATION OR WEAKNESS SHOULD BE
DISCARDED.

A LOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com
800-822-2565 215-547-3366 215-547-5260 FAX

The Company With Connections

TM

HOOP STEEL REINFORCEMENT SUPPORTS

Patent Pending

HOOP SUPPORTS
HOOP SUPPORTS
This tough, injection molded polypropylene part is designed to hold
hoop steel reinforcement securely in position in the form. Just drill a
1/4" hole in the core and insert the gray hoop steel holder. The steel
hoops are snapped into the cradle on the end of the hoop support
where they are securely held in place during the pour. The serrated
locking mechanism part of the hoop support easily snaps off when
the form is stripped out.

CRADLE

2-1/2"

This product was developed after ASTM C-478 was revised to state,
Traditional welded wire fabric reinforcement could be replaced
with continuous steel hoop reinforcement up and including
48" diameter manhole risers and conical tops.

SERRATED
LOCKING
MECHANISM

ALOK Hoop Steel Support

MATERIAL
The ALOK HOOP SUPPORTS are made from tough polypropylene.
It is best to store these parts at room temperature for ease of use.
Do not store parts in direct sunlight or cold temperatures.

KEY ADVANTAGES
The ALOK HOOP SUPPORT is an economical method to support hoop
steel reinforcement.
With the rising cost of steel reinforcement now may be the time to
consider using Hoop steel reinforcement for risers and cones, held in
place by ALOK HOOP SUPPORTS. Please review chart below to see
actual savings comparison in 2015.
PRICE COMPARISON (48" Manhole)
Welded Wire Fabric Cage -vs.- Hoop Reinforcing
Section

Ft. Hoop $ Hoop/Ft. Cost Hoop Cost WWF

Savings

1' 0" Riser

28.26 Ft.

$0.084

$2.37

$3.93

$1.56

2'0" Riser

28.26 Ft.

$0.084

$2.37

$7.86

$5.49

3'0" Riser

42.39 Ft.

$0.084

$3.56

$11.79

$8.23

4'0" Riser

42.39 Ft.

$0.084

$3.56

$15.71

$12.15

5'0" Riser

56.52 Ft.

$0.084

$4.75

$19.64

$14.89

6'0" Riser

56.52 Ft.

$0.084

$4.75

$23.57

$18.82

Notes:
1. These price comparisions are strictly raw material (steel reinforcing) costs.
2. Labor to manufacture cage/hoop and spacers in position are not included.

Hoop Supports Supporting


Hoop Steel Reinforcement

PERFORMANCE STANDARD
The ALOK HOOP SUPPORT meets or exceeds the following ASTM
requirements.
Physical Properties

Metric

English

Comments

Density
Melt Flow

0.902 g/cc
100 g/10 min

0.0326 lb/in3
100 g/10 min

ASTM D792
230C/2.16 kg-L;
ASTM D1238

Mechanical Properties

Metric

English

Comments

Tensile Strength @ Yield


Elongation at Yield
Flexural Modulus

27.6 MPa
4.00%
1.45 GPa

4000 psi
4.00%
210 ksi

Izod Impact, Notched

0.534 J/cm

1.00 ft-lb/in

ASTM D638
ASTM D638
1% Secant,
0.05 in/min;
ASTM D790
73F; ASTM D256

Thermal Properties

Metric

English

Comments

Deflection Temperature
at 9.46 MPa (66 psi)

123 C

253 F

Unannealed;
ASTM D648

Copyright ASTM INTERNATIONAL. Reprinted with permission

INSTALLATION INSTRUCTIONS
Preparing Core to mount hoop supports Best results can be achieved
by: Take care when drilling the 1/4" holes in core for mounting each
ALOK HOOP SUPPORT, to achieve an accurate size hole. Start with a
1/8" pilot hole or use a magnetic drill to help assure accurate size as well
as a clean sharp edge on the drilled hole. Manhole risers and conical tops
up to 24" in height should have no less than two hoops of steel wire.
Suggested: 4 (four) ALOK Hoop Supports for each hoop would require
drilling 8 holes in the core. For heights greater than 24" and up to and
including 48" no less than 3 hoops of steel reinforcement shall be used.
Three hoops will require 12 holes be drilled in the core to hold the 12
hoop supports, 4 for each hoop. For heights between 48" and 72" 4
hoops of reinforcement will be required. See hoop steel detail drawings.

STEP 1: Align locking


mechanism into drilled hole.

STEP 2: Insert locking


mechanism into drilled hole.

REINFORCEMENT POSITIONING
1. Hoop wire size risers and cones: Steel hoop wire shall have a
minimal cross section diameter of 0.250 inches.
2. Hoop diameters for cones and risers will be such that the hoops are
cast into the middle 1/3 of the wall.

RISERS:

CONES:

2' to 4' Cones

/4" Dia Wire


Hoops

2' to 4' Risers

A-LOK SUGGESTS 4 HOOP SUPPORTS TO HOLD EACH


STEEL HOOP SECURELY IN PLACE.

STEP 3: Align Hoop in Cradle


all the way around.

STEP 4: Ready for pour.

HOOP STEEL DETAIL DRAWINGS FOR RISERS


WITH STEPS
NOTE: DIMENSIONS ARE SHOWN WITH
A TOLERANCE SO YOU CAN AVOID STEP
INSERTS AND LIFT PINS.

3. Hoop position top to bottom risers and cones: A hoop will be located
in each end quarter of the riser or cone with a minimum distance of
1 (one) inch from the shoulder. The 3rd or middle hoop shall be
located from the shoulder of the riser or cone a distance equal to
one-half the section height + or 6 inches.
4. The concrete cover over the hoop reinforcement in the wall section
shall be no less than 3/4".
Refer to ASTM C 478-07 Section 14.5

BEST PRACTICES FOR


PLACING CONCRETE
The form should be filled slowly to avoid
adding any additional energy to the mix,
causing unwanted segregation or shifting of
reinforcement, block outs or inserts. Care
should also be taken when using any internal
vibrators around hoops or hoop supports to
avoid contact that could change the position
of the hoops or break off hoop supports.

ANY QUESTIONS REGARDING ALOK HOOP SUPPORT INSTALLATION, PLEASE CALL 1-800-822-2565
2007 A-LOK Products, Inc. Supersedes all previous literature. COVERED BY ISSUED AND/OR PENDING PATENTS

ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com
800-822-2565 215-547-3366 215-547-5260 FAX

11/07

The Company With Connections

TM

SLOTTED INSERT TO ANCHOR CAST IRON FRAME TO STRUCTURE

BOLT SLOT INSERT


ALOK BOLT SLOT INSERT

KEY ADVANTAGES
Guaranteed alignment of galvanized nut and bolt centers of manhole frame.
The .75 inch square nut is galvanized to prevent corrosion.
In traffic areas, misalignment of frame and structure top is eliminated due to shifting or movement during construction, or during
routine maintenance.
In easement areas, the frame assembly is protected against theft
or vandalism by being firmly secured to the structure.
Precast top sections can be standardized to accept any manhole
frame regardless of bolt centers.

The ALOK BOLT SLOT INSERT is a slotted insert designed to be


cast into the conical or slab top section of underground concrete
structures for the purpose of anchoring the cast iron frame to the
structure. The insert assembly consists of a tough polypropylene shell
and a .75 inch square galvanized nut.
The key purpose of the insert is to allow for center to center adjustment of the .75 inch galvanized nut to match the bolt center of the
manhole frame. Traditional anchoring inserts require precise positioning on center to assure proper alignment of assembly. With the availability of the Bolt SLot Insert in overall lengths of 3 inches and 6 inches, any manhole frame can be accommodated regardless of bolt centers.
The inserts are shipped assembled for standard installation into the
precast top section.
Inserts are held in position during the casting operation by a FourWay Installation Holder in the four quadrants on a predetermined
center to allow maximum adjustment in matching the bolt center of
the manhole frame.

PRODUCT REFERENCES
A.) ASTM C-1244
Standard Test Method For Concrete Sewer Manholes
by the Negative Air Pressure (Vacuum) Test

B.) ASTM C-478


Standard Specification for Precast Reinforced Concrete
Manhole Sections

C.) FEDERAL REGULATION


CODE RR-F-621
Specification for Frame, Covers, Gratings, Steps,
Sump Catch Basins, Manholes

MATERIAL
The insert is molded from a copolymer polypropylene compound. The
.75 inch square nut is galvanized.

PART 6 DIMENSIONAL DATA


PART
NUMBER
3 BOLT
4 BOLT
6 BOLT

LENGTH
3.125
4.125
6.125

INSERT
ADJUSTMENT
CAPABILITY
1.50
2.00
3.00

3", 4" or 6" BOLT SLOT

INSTALLATION INSTRUCTIONS
PLANT INSTALLATION

FIELD INSTALLATION

1. Load Four-Way Installation Holder by sliding the (4) ALOK BOLT


SLOTS on to the Pads. Position each insert alike on the Pads to
assure uniform placement in the precast section.

1. Prior to placing the grade rings and manhole frame on the concrete structure, the sealing tab is removed from the top of the
ALOK BOLT SLOT to gain access to the .75 inch square nut.

2. Pour concrete in form to desired level, and then press loaded


Four-Way Installation Holder into concrete keeping common center of holder and core opening properly aligned.

2. An all thread rod is then threaded into .75 inch nut and adjusted
to the proper center to match frame.

3. When loaded holder and inserts have reached their proper position, use trowel to place concrete around inserts and finish top
area.

3. After the grade work and frame are in place, the top nuts are
installed and tightened and excess rod is cut off.

4. When concrete has hardened, Four-Way Installation Holder and


Pads can be removed.

TYPICAL BOLT SLOT DETAIL

TYPICAL WATERTIGHT ASSEMBLY


(WITH GRADE WORK)

TYPICAL WATERTIGHT ASSEMBLY


(WITH NO GRADE WORK)

ANY QUESTIONS REGARDING ALOK BOLT SLOT INSERT INSTALLATION, PLEASE CALL 1-800-822-2565

ALOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com
800-822-2565 215-547-3366 215-547-5260 FAX

AV-202 Multigrout Page 06

AV-202 Multigrout Page 03

Specific Description of AV-202 Multigrout

Instructions for Using AV-202 Multigrout

Safety Procedures

AV-202 Multigrout is a hydrophilic polymer. The uncured material is a


caramel colored, translucent liquid with a viscosity in the 2500
centipoise range at 86F. At workable water to polymer ratios, however,
the viscosity can be adjusted to approach the 15 to 30 centipoise range.
AV-202 contains non-volatile materials constituting almost 100% of its
total weight.

Although the AV-202 Multigrout pre-polymer is a relatively thick material,


it is easily handled with commercially available positive displacement
pumps. AV-202 Multigrout is designed to cure with water, and may
absorb large quantities into the reaction mass. The ratio of water to
AV-202 Multigrout chosen depends upon the application. For most
applications which require the use of gels, the water to AV-202
Multigrout ratio should be in the range of 10:1 to 15:1 by volume.

Summary of Handling Precautions


1. Wear goggles and rubber gloves in handling and application
operations.
2. Keep away from heat and open flame during storage and use.
3. Ventilate sufficiently and use respirator, especially for operations
in a confined space.
4. If skin or mucous membrane is contaminated with Multigrout or
its solutions, wash thoroughly with plenty of water. In case
of eye contact, wash immediately with plenty of water and boric
acid solution, and seek medical attention.

When mixed with a specific quantity of water, the material can expand
10 to 12 times its original volume and cure to a tough, flexible and
elastomeric condition. After completely curing, the AV-202 may exhibit
strength properties of up to 80 psi tensile and 500% elongation.

Physical Properties of AV-202 Multigrout


The physical properties of monolithic films prepared with Multigrout
are summarized as follows:

Table One:
Water : AV-202
Ratio

% AV-202*

20:1
10:1
5:1

5%
10%
20%

Tensile Strength

Elongation

Tear Strength

(kg/cm2)

(%)

(kg/cm2)

100
150
600

15
18
20

120
100
46**

* Concentration by weight of Multigrout in the aqueous solution


used to prepare a monolithic film.
** A foamy film is obtained when concentration is higher than 20%,
i.e., less than five parts of water to one part of AV-202 Multigrout.

Higher ratios (i.e., greater than 15:1) give lower initial viscosities and
longer gel times but reduce the unconfined compressive strength of the
consolidated material in the grout zone. Such high ratios are primarily
used for short-term erosion control of surface soils.

During the initial reaction stage of Multigrout with water, amines and
carbon dioxide are generated by a reaction with water in the soil or
water injected with the grout pump at the site of the leak to be sealed.
Then, the resultant amines react quickly with an isocyanate group to
form compounds with a three-dimensional structure cross-linked with
urea and biuret linkages. These compounds form a gel which is
insoluble in water.

Table Two:
Chemical Properties

Flash Point
Corrosiveness
Reactivity

UL Water Product Certification


ANSI/NSF Standard 61 encompasses
products that come in contact with
drinking water and/or drinking water
treatment chemicals. Products covered
by this standard include:
EPH

ANSI/NSF 61
DRINKING WATER SYSTEM COMPONENTS
88NN

1. Pipes and related products


2. Barrier materials, i.e., coatings, linings
3. Joining and sealing materials, i.e.,
adhesives, gaskets

Warranty Statement

The initial mixed viscosity of the water to AV-202 Multigrout blend is


important in determining the soils that can be penetrated and pumping
pressure required. With the AV-202 Multigrout system, the initial mixed
viscosity is dependent primarily on the water to AV-202 Multigrout ratio
and water temperature.

The data, information, and statements contained herein are believed


to be reliable, but are not construed as a warranty or representation
for which Avanti International assumes any legal responsibility. Since
field conditions vary widely, users must undertake sufficient verification and testing to determine the suitability of any product or process
mentioned in this or any other written material from Avanti for their
own particular use.

The linearity of the rate at which the viscosity of the mixed grout
increases from the time of mixing up to gelation is a second important
factor in determining the degree and types of soil that can be
penetrated. With the AV-202 Multigrout, the viscosity remains low for
the initial 60 to 70% of the gel time and then increases rapidly as the
blend approaches gelation.

NO WARRANT OF SUITABILITY OR FITNESS FOR A PARTICULAR


PURPOSE IS MADE.
Nothing in this or any other document from Avanti International is to
be taken as permission, inducement, or recommendation to practice
any patented invention without a license.

The relationship between temperature and viscosity of AV-202


Multigrout pre-polymer (prior to mixture with water) is illustrated in
Table Three.

AV-202

Table Three:
Temperature

Chemical Properties

continued.

Technical Manual

Viscosity

CPS

104
95
86
77
68
59
50

40
35
30
25
20
15
10

500
1000
2500
3500
5500
9000
14000

Multigrout

EPH

ANSI/NSF 61
DRINKING WATER SYSTEM COMPONENTS
88NN

The relationship between the concentration of Multigrout


(water/polymer ratio) and the properties of the resultant material is in
Table Four.

AvantiGrout stops leaks. Permanently.

200C
Non-corrosive
Reacts readily with water

Technical Manual

822 Bay Star Boulevard


Webster, Texas 77598
800 . 877 . 2570
281 . 486 . 5600

Copyright 2005 Avanti International

www.avantigrout.com
AL-02P3

AL-02P6

www.avantigrout.com
AL-02P1

AV-202 Multigrout Page 04

AV-202 Multigrout Page 02

Introduction

General Information

AV-202 Multigrout is a chemical grout system of water-soluble


hydrophilic polyurethane pre-polymers. Multigrout reacts freely with
water to form a strong film, gel or foam according to the mix design
requirements of the application. This capability makes Multigrout ideal
for use as a remedial water stop in a wide range of construction
applications.

For example, by combining Multigrout with water in a ratio of


one part Multigrout and 1 to 5 parts of water, the resulting foam might
be used to fill an abandoned pipeline. With a greater ratio of water to
Multigrout, perhaps in the range of 1 part Multigrout to 10 parts of
water, the product can be injected into a subsurface structure to seal
cracks in concrete. By increasing the water ratio even higher to
perhaps a 1 to 20 ratio of Multigrout to water, the resilient gel can be
effectively used as an impermeable barrier for other applications.

continued.

Instructions

AV-202 Multigrout Page 05

Estimating AV-202 Application Req.

continued.

continued.

Cleanup Procedures

continued.

Table Six:

As the ratio of water to Multigrout increases, the viscosity of the mixture


decreases. The nature of a particular application dictates the proper
ratio of Multigrout to water and experience is the best teacher for how to
choose the correct mixture. An operator must always bear in mind that
each application is unique and requires planning. The ideal goal should
always be a balance between an initial product viscosity that makes
placement effective and easy and a final product that will accomplish
the job at hand.
An outstanding feature of AV-202 Multigrout is its adaptability to any of
several water stop requirements. In an application needing a foam, for
example, the product is appropriate as well as another application
where a resilient gel is required. The property of the end product is
easily controlled by any application program. Furthermore, AV-202
Multigrout can also be altered during a grouting program. For example,
a quick foam can be formed initially and later backed up with a dense,
strong gel, all from the same basic product. Complex grouting
applications can often be simplified by the use of AV-202 Multigrout.

AV-202 Multigrout has a strong affinity for water. Although normally


not required, standard static mixers may be used. Upon curing, the
gel can contain many times its own volume of water. The mixture of
AV-202 Multigrout and water is initially low in viscosity and can be
injected under pressure to seal voids, fissures or cracks. Once the
gel has cured, it is resistant to water, thus reducing permeability and
forming an effective water shut off system. The cured grout also
increases the strength of the soil mass and consolidates the soil.

When AV-202 Multigrout is mixed with a small amount of water, a


reaction proceeds through two stages: foam stage and cure stage.

Ratio Range
Water : Multigrout

General Properties

50% to 20%
12% to 9%
6% to 5%
4% to 3%
2% to 1%

1:1 to 5:1
7:1 to 10:1
16:1 to 20:1
25:1 to 49:1
50:1 to 100:1

Foam
Expansive Gel
Soft Gel
Very Weak Gel
Emulsion

Gel time is defined as the time interval from initial mixing of AV-202
to the point where the blend viscosity is too high for gravity flow.

Gel time is controlled primarily by two factors:


1. Water temperature
2. Water : AV-202 ratio

Due to the adaptability of AV-202


Multigrout, the product is appropriate for
many different waterproofing and sealing
problems. It may be injected with a
positive displacement pump or used
with AV-219 (Oakum) for large cracks or
joints and placed by hand. The ability to
control the physical properties of the
final product gives the applicator a tool
for a wide variety of grouting programs.
For injection placement, the best
equipment is a positive displacement
pump such as the Graco Airless Sprayer.

Lower water temperatures and higher water to AV-202 ratios give


longer gel and tack free times. Gel times may also vary slightly with
the age of the AV-202 and chemical content of the water.
Table Five depicts the relationship between gel time and
concentration of Multigrout with gel time measured at 3 levels of
temperature in the aqueous solution.

Table Five:
Water : AV-202

Both stages of the grout must be understood and controlled to


obtain good results. The ambient temperature of the grout is the
primary variable that affects foam and cure times.

If unrestrained, the material may expand up to ten times the original


unreacted volume of grout and water. Unrestrained expansion,
however, results in a foam of low density. A compacted foam is more
desirable for most applications and fillers or reinforcements such as
oakum may be used to provide acceptable density.
Following the foam stage is the cure stage. During the cure stage,
the grout solidifies and forms a cellular rubber gasket (reinforced by
oakum if it has been added) which can withstand a water pressure
test. After placement and the foam stage, the grout will continue to
cure over the next several hours; however, within five to ten minutes
it has achieved sufficient strength to form a serviceable water barrier.

AV-202 : Water Ratio

Foam Time in Minutes at 78F

10:1
9:1
8:1
6:1
4:1
2:1
1:1

18.00
14.25
11.00
8.00
4.25
2.50
1.50

Data shows that the permeability of a soil grouted with AV-202 in gel
form is a function of the extent that voids are filled with grout.
Values in the 10-7 to 10-9 cm/sec range should be obtained when
voids are essentially full of grout using the constant head
permeability test method (ASTM D-2434).

Other factors may affect quantities required. These figures are intended
only as a guide.

Normally an overnight soak will dissolve most deposits and sufficiently


soften them for easy removal.

In joints, the primary factor influencing the quantity of AV-202 Multigrout


required to seal a given joint is the size of the joint gap. The amount of
AV-202 required will be less if old joint compounds still partially fill the
joint. As a rough rule of thumb, one fluid ounce of AV-202 will be
required per lineal inch of joint having a gap of one inch between the bell
and spigot.

To clean the entire grouting system, flush grout from system with up
to 5 gallons of AV-208 (Technical Grade Acetone). Pump until
acetone runs clean. DO NOT REUSE.

Actual examination of joint conditions, coupled with considerable


experience, is necessary to accurately estimate grout quantities. This is
particularly true for sealing large diameter pipe joints as shown in
Figure 1. In some instances, special equipment and techniques can be
employed to reduce material quantities required without affecting the
quality of the seal. Project planners are strongly encouraged to consult
with an approved applicator of Avanti products or an experienced
grouting contractor when preparing material cost estimates.

Estimating AV-202 Application Requirements

Ratio

Temperature ( F )

68

80

86

2:1
5:1
8:1
10:1
12:1
14:1
16:1
18:1
20:1

1.00
1.50
2.05
2.75
3.30
4.75
6.25
10.50
15.00

0.50
1.00
1.50
2.00
2.50
3.50
4.60
7.70
11.00

0.35
0.90
1.25
1.40
1.80
2.50
3.20
5.40
7.80

Table Six illustrates the relationship between foam time and


concentration of Multigrout. Foam time was measured at 78
temperature in the aqueous solution. The foam requires approximately
an equal amount of time to reach a tack free condition after its
initial set.

Application of AV-202 Multigrout

AV-202 is designed to be used by qualified applicators with the


proper equipment. Grouting equipment for the application of this
product is available from Avanti International.

The EGP Technique


The Expanded Gasket Placement Technique (EGP) is the process
whereby jute strips, soaked in AV-202, are then packed around various
types of pipe to achieve a very effective seal. For further information
concerning EGP, consult the Avanti EGP brochure, which can be
downloaded from the Avanti website at www.avantigrout.com.

60
50
40
30
20

0
36

Set Time in Minutes

Within 15 to 45 seconds after mixing, depending on mix ratios and


the temperature of the grout and mix water, the material will begin to
foam. The viscosity is such that the grout will not readily flow out of
the point of placement, i.e., into the pipe or the soil outside of the
pipe.

General Information

AV-202
Multigrout

AV-202 Multigrout is often used for grouting joints and repairing leaks
in large sanitary and storm sewer pipes by forming a flexible gasket or
plug in the flowing water path. In an uncured form, AV-202 is a
viscous liquid similar in appearance to common honey. When mixed
with a small amount of water, however, the grout expands and rapidly
cures to a tough, flexible, cellular rubber that is essentially unaffected
by sewer environments.

Percentage
Multigrout : Total Volume

Grout - pounds

The form of the final product, whether it is film, gel or foam, is controlled
by the ratio of water to AV-202 Multigrout. For example, a mixture of 1
part Multigrout and from 1 to 5 parts water will produce a product with
the general properties of a foam. A mixture of 1 part Multigrout and
approximately 7 to 10 parts water will result in a resilient gel. A mixture
of 1 part Multigrout and 16 to 20 parts water will result in a soft gel.
Ratios of 1 part Multigrout and 25 to 30 parts water create a very soft
gel. The specific physical properties of AV-202 Multigrout, when
combined with water in various ratios, are depicted later in this manual.

Table Four:

42

48

60

72

84

96

108

120

Pipe Diameter - inches

Figure 1: AV-202 Multigrout required for large diameter pipes.


Note: Refer to Avanti Internationals Large Diameter Pipe Sealing
Specification available online at www.avantigrout.com.
The quantities of AV-202 Multigrout required to rehabilitate or repair
concrete pipe joints of various diameters are shown in Figure 1. These
quantity estimates are based on actual field experience but may vary
slightly in the smaller diameter pipe and substantially in the larger
diameter pipe.

Some factors which may affect the quantity of AV-202 required are:
1. Original gasketing materials remaining in the joint.
2. Open or off-set condition of the joint.
3. Severity of infiltration or exfiltration at the joint.
4. Type and condition of grouting equipment to be used.
5. Application method used.

The V-PAT Technique for Sealing Joints and Cracks


The Variable Pressure Application Technique (V-PAT) can be used to
apply pure AV-202 Multigrout resin in both cracks and expansion joints.
The methods used for these two water control problems are somewhat
different, but the basic steps are the same. The procedures for sealing
cracks and joints by the V-PAT method may be found on the Avanti
website at www.avantigrout.com.

Cleanup Procedures
Cleaning
Most day-to-day cleanup and purging of nonhydrated grout (liquid
AV-202 that has not been exposed to water or moisture) from pumps,
fittings, and hoses can be accomplished with AV-208 (Technical Grade
Acetone). Although acetone is preferred, MEK or other solvents are
sometimes used. When using solvents for cleanup, extinguish all
sources of ignition in the area and observe proper precautionary
measures for handling such materials. If small component parts must
be cleaned of cured grout, it is best to disassemble and soak them in a
100% solution of AV-222 Grout Cleaner. (Always use polyethylene
plastic or steel containers for soaking).

Safety During Cleanup


Acetone is flammable and the precautions necessary for any flammable
material should be followed. Since grout compound which comes into
contact with clothing cannot be removed, rain gear or disposable
coveralls are highly recommended. Hats or hoods help keep the
material from dripping into the hair during overhead application.
Handling and Storage of AV-202 Multigrout
Care must be taken in handling and storage of AV-202 Multigrout. The
material is sensitive to moisture and moderately sensitive to high
storage temperatures. Optimum storage is 40-60F under fairly dry
conditions. Storage temperature should not exceed 80F. Properly
stored, the material should have a useful shelf life of two years. Once a
container has been opened, the useful life of the material is reduced.

Safety Procedures
Please refer to the Avanti AV-202 Multigrout MSDS available online at
www.avantigrout.com.

Exposure
AV-202 Multigrout in nonhydrated or liquid form may cause skin and eye
irritation following direct contact. If AV-202 comes in contact with skin,
it should be washed off with soap and water. Material getting into the
eyes must be flushed out immediately with water and a physician
should be consulted. AV-202 Multigrout should not be ingested.
Before eating, smoking, or drinking liquids, remove protective clothing
such as gloves and coveralls, wash hands with soap and water and
stand away from the immediate work site. DO NOT SMOKE while
working with AV-202 Multigrout. If respiratory difficulties are encountered when working with AV-202 Multigrout, obtain medical attention.
Users should avoid excessive exposure to vapors and keep the work
area sufficiently ventilated to avoid exceeding the toluene diisocyanate
Threshold Limit Value (TLV). Gloves, goggles, respirator, and protective
clothing are recommended when working with this product.

Ventilation
Ventilation is an important aspect of project planning. Small amounts of
toluene diisocyanate (TDI) may be present. A small segment of the
population may be more sensitive to TDI than the norm. A respirator
equipped with an organic vapor cartridge should always be available
and ventilation augmented by blowers or fans when appropriate.

AvantiGrout stops leaks. Permanently.


AL-02P2

AL-02P4

AL-02P5

AV-202 Multigrout Page 06

AV-202 Multigrout Page 03

Specific Description of AV-202 Multigrout

Instructions for Using AV-202 Multigrout

Safety Procedures

AV-202 Multigrout is a hydrophilic polymer. The uncured material is a


caramel colored, translucent liquid with a viscosity in the 2500
centipoise range at 86F. At workable water to polymer ratios, however,
the viscosity can be adjusted to approach the 15 to 30 centipoise range.
AV-202 contains non-volatile materials constituting almost 100% of its
total weight.

Although the AV-202 Multigrout pre-polymer is a relatively thick material,


it is easily handled with commercially available positive displacement
pumps. AV-202 Multigrout is designed to cure with water, and may
absorb large quantities into the reaction mass. The ratio of water to
AV-202 Multigrout chosen depends upon the application. For most
applications which require the use of gels, the water to AV-202
Multigrout ratio should be in the range of 10:1 to 15:1 by volume.

Summary of Handling Precautions


1. Wear goggles and rubber gloves in handling and application
operations.
2. Keep away from heat and open flame during storage and use.
3. Ventilate sufficiently and use respirator, especially for operations
in a confined space.
4. If skin or mucous membrane is contaminated with Multigrout or
its solutions, wash thoroughly with plenty of water. In case
of eye contact, wash immediately with plenty of water and boric
acid solution, and seek medical attention.

When mixed with a specific quantity of water, the material can expand
10 to 12 times its original volume and cure to a tough, flexible and
elastomeric condition. After completely curing, the AV-202 may exhibit
strength properties of up to 80 psi tensile and 500% elongation.

Physical Properties of AV-202 Multigrout


The physical properties of monolithic films prepared with Multigrout
are summarized as follows:

Table One:
Water : AV-202
Ratio

% AV-202*

20:1
10:1
5:1

5%
10%
20%

Tensile Strength

Elongation

Tear Strength

(kg/cm2)

(%)

(kg/cm2)

100
150
600

15
18
20

120
100
46**

* Concentration by weight of Multigrout in the aqueous solution


used to prepare a monolithic film.
** A foamy film is obtained when concentration is higher than 20%,
i.e., less than five parts of water to one part of AV-202 Multigrout.

Higher ratios (i.e., greater than 15:1) give lower initial viscosities and
longer gel times but reduce the unconfined compressive strength of the
consolidated material in the grout zone. Such high ratios are primarily
used for short-term erosion control of surface soils.

During the initial reaction stage of Multigrout with water, amines and
carbon dioxide are generated by a reaction with water in the soil or
water injected with the grout pump at the site of the leak to be sealed.
Then, the resultant amines react quickly with an isocyanate group to
form compounds with a three-dimensional structure cross-linked with
urea and biuret linkages. These compounds form a gel which is
insoluble in water.

Table Two:
Chemical Properties

Flash Point
Corrosiveness
Reactivity

UL Water Product Certification


ANSI/NSF Standard 61 encompasses
products that come in contact with
drinking water and/or drinking water
treatment chemicals. Products covered
by this standard include:
EPH

ANSI/NSF 61
DRINKING WATER SYSTEM COMPONENTS
88NN

1. Pipes and related products


2. Barrier materials, i.e., coatings, linings
3. Joining and sealing materials, i.e.,
adhesives, gaskets

Warranty Statement

The initial mixed viscosity of the water to AV-202 Multigrout blend is


important in determining the soils that can be penetrated and pumping
pressure required. With the AV-202 Multigrout system, the initial mixed
viscosity is dependent primarily on the water to AV-202 Multigrout ratio
and water temperature.

The data, information, and statements contained herein are believed


to be reliable, but are not construed as a warranty or representation
for which Avanti International assumes any legal responsibility. Since
field conditions vary widely, users must undertake sufficient verification and testing to determine the suitability of any product or process
mentioned in this or any other written material from Avanti for their
own particular use.

The linearity of the rate at which the viscosity of the mixed grout
increases from the time of mixing up to gelation is a second important
factor in determining the degree and types of soil that can be
penetrated. With the AV-202 Multigrout, the viscosity remains low for
the initial 60 to 70% of the gel time and then increases rapidly as the
blend approaches gelation.

NO WARRANT OF SUITABILITY OR FITNESS FOR A PARTICULAR


PURPOSE IS MADE.
Nothing in this or any other document from Avanti International is to
be taken as permission, inducement, or recommendation to practice
any patented invention without a license.

The relationship between temperature and viscosity of AV-202


Multigrout pre-polymer (prior to mixture with water) is illustrated in
Table Three.

AV-202

Table Three:
Temperature

Chemical Properties

continued.

Technical Manual

Viscosity

CPS

104
95
86
77
68
59
50

40
35
30
25
20
15
10

500
1000
2500
3500
5500
9000
14000

Multigrout

EPH

ANSI/NSF 61
DRINKING WATER SYSTEM COMPONENTS
88NN

The relationship between the concentration of Multigrout


(water/polymer ratio) and the properties of the resultant material is in
Table Four.

AvantiGrout stops leaks. Permanently.

200C
Non-corrosive
Reacts readily with water

Technical Manual

822 Bay Star Boulevard


Webster, Texas 77598
800 . 877 . 2570
281 . 486 . 5600

Copyright 2005 Avanti International

www.avantigrout.com
AL-02P3

AL-02P6

www.avantigrout.com
AL-02P1

AV-202 Multigrout Page 04

AV-202 Multigrout Page 02

Introduction

General Information

AV-202 Multigrout is a chemical grout system of water-soluble


hydrophilic polyurethane pre-polymers. Multigrout reacts freely with
water to form a strong film, gel or foam according to the mix design
requirements of the application. This capability makes Multigrout ideal
for use as a remedial water stop in a wide range of construction
applications.

For example, by combining Multigrout with water in a ratio of


one part Multigrout and 1 to 5 parts of water, the resulting foam might
be used to fill an abandoned pipeline. With a greater ratio of water to
Multigrout, perhaps in the range of 1 part Multigrout to 10 parts of
water, the product can be injected into a subsurface structure to seal
cracks in concrete. By increasing the water ratio even higher to
perhaps a 1 to 20 ratio of Multigrout to water, the resilient gel can be
effectively used as an impermeable barrier for other applications.

continued.

Instructions

AV-202 Multigrout Page 05

Estimating AV-202 Application Req.

continued.

continued.

Cleanup Procedures

continued.

Table Six:

As the ratio of water to Multigrout increases, the viscosity of the mixture


decreases. The nature of a particular application dictates the proper
ratio of Multigrout to water and experience is the best teacher for how to
choose the correct mixture. An operator must always bear in mind that
each application is unique and requires planning. The ideal goal should
always be a balance between an initial product viscosity that makes
placement effective and easy and a final product that will accomplish
the job at hand.
An outstanding feature of AV-202 Multigrout is its adaptability to any of
several water stop requirements. In an application needing a foam, for
example, the product is appropriate as well as another application
where a resilient gel is required. The property of the end product is
easily controlled by any application program. Furthermore, AV-202
Multigrout can also be altered during a grouting program. For example,
a quick foam can be formed initially and later backed up with a dense,
strong gel, all from the same basic product. Complex grouting
applications can often be simplified by the use of AV-202 Multigrout.

AV-202 Multigrout has a strong affinity for water. Although normally


not required, standard static mixers may be used. Upon curing, the
gel can contain many times its own volume of water. The mixture of
AV-202 Multigrout and water is initially low in viscosity and can be
injected under pressure to seal voids, fissures or cracks. Once the
gel has cured, it is resistant to water, thus reducing permeability and
forming an effective water shut off system. The cured grout also
increases the strength of the soil mass and consolidates the soil.

When AV-202 Multigrout is mixed with a small amount of water, a


reaction proceeds through two stages: foam stage and cure stage.

Ratio Range
Water : Multigrout

General Properties

50% to 20%
12% to 9%
6% to 5%
4% to 3%
2% to 1%

1:1 to 5:1
7:1 to 10:1
16:1 to 20:1
25:1 to 49:1
50:1 to 100:1

Foam
Expansive Gel
Soft Gel
Very Weak Gel
Emulsion

Gel time is defined as the time interval from initial mixing of AV-202
to the point where the blend viscosity is too high for gravity flow.

Gel time is controlled primarily by two factors:


1. Water temperature
2. Water : AV-202 ratio

Due to the adaptability of AV-202


Multigrout, the product is appropriate for
many different waterproofing and sealing
problems. It may be injected with a
positive displacement pump or used
with AV-219 (Oakum) for large cracks or
joints and placed by hand. The ability to
control the physical properties of the
final product gives the applicator a tool
for a wide variety of grouting programs.
For injection placement, the best
equipment is a positive displacement
pump such as the Graco Airless Sprayer.

Lower water temperatures and higher water to AV-202 ratios give


longer gel and tack free times. Gel times may also vary slightly with
the age of the AV-202 and chemical content of the water.
Table Five depicts the relationship between gel time and
concentration of Multigrout with gel time measured at 3 levels of
temperature in the aqueous solution.

Table Five:
Water : AV-202

Both stages of the grout must be understood and controlled to


obtain good results. The ambient temperature of the grout is the
primary variable that affects foam and cure times.

If unrestrained, the material may expand up to ten times the original


unreacted volume of grout and water. Unrestrained expansion,
however, results in a foam of low density. A compacted foam is more
desirable for most applications and fillers or reinforcements such as
oakum may be used to provide acceptable density.
Following the foam stage is the cure stage. During the cure stage,
the grout solidifies and forms a cellular rubber gasket (reinforced by
oakum if it has been added) which can withstand a water pressure
test. After placement and the foam stage, the grout will continue to
cure over the next several hours; however, within five to ten minutes
it has achieved sufficient strength to form a serviceable water barrier.

AV-202 : Water Ratio

Foam Time in Minutes at 78F

10:1
9:1
8:1
6:1
4:1
2:1
1:1

18.00
14.25
11.00
8.00
4.25
2.50
1.50

Data shows that the permeability of a soil grouted with AV-202 in gel
form is a function of the extent that voids are filled with grout.
Values in the 10-7 to 10-9 cm/sec range should be obtained when
voids are essentially full of grout using the constant head
permeability test method (ASTM D-2434).

Other factors may affect quantities required. These figures are intended
only as a guide.

Normally an overnight soak will dissolve most deposits and sufficiently


soften them for easy removal.

In joints, the primary factor influencing the quantity of AV-202 Multigrout


required to seal a given joint is the size of the joint gap. The amount of
AV-202 required will be less if old joint compounds still partially fill the
joint. As a rough rule of thumb, one fluid ounce of AV-202 will be
required per lineal inch of joint having a gap of one inch between the bell
and spigot.

To clean the entire grouting system, flush grout from system with up
to 5 gallons of AV-208 (Technical Grade Acetone). Pump until
acetone runs clean. DO NOT REUSE.

Actual examination of joint conditions, coupled with considerable


experience, is necessary to accurately estimate grout quantities. This is
particularly true for sealing large diameter pipe joints as shown in
Figure 1. In some instances, special equipment and techniques can be
employed to reduce material quantities required without affecting the
quality of the seal. Project planners are strongly encouraged to consult
with an approved applicator of Avanti products or an experienced
grouting contractor when preparing material cost estimates.

Estimating AV-202 Application Requirements

Ratio

Temperature ( F )

68

80

86

2:1
5:1
8:1
10:1
12:1
14:1
16:1
18:1
20:1

1.00
1.50
2.05
2.75
3.30
4.75
6.25
10.50
15.00

0.50
1.00
1.50
2.00
2.50
3.50
4.60
7.70
11.00

0.35
0.90
1.25
1.40
1.80
2.50
3.20
5.40
7.80

Table Six illustrates the relationship between foam time and


concentration of Multigrout. Foam time was measured at 78
temperature in the aqueous solution. The foam requires approximately
an equal amount of time to reach a tack free condition after its
initial set.

Application of AV-202 Multigrout

AV-202 is designed to be used by qualified applicators with the


proper equipment. Grouting equipment for the application of this
product is available from Avanti International.

The EGP Technique


The Expanded Gasket Placement Technique (EGP) is the process
whereby jute strips, soaked in AV-202, are then packed around various
types of pipe to achieve a very effective seal. For further information
concerning EGP, consult the Avanti EGP brochure, which can be
downloaded from the Avanti website at www.avantigrout.com.

60
50
40
30
20

0
36

Set Time in Minutes

Within 15 to 45 seconds after mixing, depending on mix ratios and


the temperature of the grout and mix water, the material will begin to
foam. The viscosity is such that the grout will not readily flow out of
the point of placement, i.e., into the pipe or the soil outside of the
pipe.

General Information

AV-202
Multigrout

AV-202 Multigrout is often used for grouting joints and repairing leaks
in large sanitary and storm sewer pipes by forming a flexible gasket or
plug in the flowing water path. In an uncured form, AV-202 is a
viscous liquid similar in appearance to common honey. When mixed
with a small amount of water, however, the grout expands and rapidly
cures to a tough, flexible, cellular rubber that is essentially unaffected
by sewer environments.

Percentage
Multigrout : Total Volume

Grout - pounds

The form of the final product, whether it is film, gel or foam, is controlled
by the ratio of water to AV-202 Multigrout. For example, a mixture of 1
part Multigrout and from 1 to 5 parts water will produce a product with
the general properties of a foam. A mixture of 1 part Multigrout and
approximately 7 to 10 parts water will result in a resilient gel. A mixture
of 1 part Multigrout and 16 to 20 parts water will result in a soft gel.
Ratios of 1 part Multigrout and 25 to 30 parts water create a very soft
gel. The specific physical properties of AV-202 Multigrout, when
combined with water in various ratios, are depicted later in this manual.

Table Four:

42

48

60

72

84

96

108

120

Pipe Diameter - inches

Figure 1: AV-202 Multigrout required for large diameter pipes.


Note: Refer to Avanti Internationals Large Diameter Pipe Sealing
Specification available online at www.avantigrout.com.
The quantities of AV-202 Multigrout required to rehabilitate or repair
concrete pipe joints of various diameters are shown in Figure 1. These
quantity estimates are based on actual field experience but may vary
slightly in the smaller diameter pipe and substantially in the larger
diameter pipe.

Some factors which may affect the quantity of AV-202 required are:
1. Original gasketing materials remaining in the joint.
2. Open or off-set condition of the joint.
3. Severity of infiltration or exfiltration at the joint.
4. Type and condition of grouting equipment to be used.
5. Application method used.

The V-PAT Technique for Sealing Joints and Cracks


The Variable Pressure Application Technique (V-PAT) can be used to
apply pure AV-202 Multigrout resin in both cracks and expansion joints.
The methods used for these two water control problems are somewhat
different, but the basic steps are the same. The procedures for sealing
cracks and joints by the V-PAT method may be found on the Avanti
website at www.avantigrout.com.

Cleanup Procedures
Cleaning
Most day-to-day cleanup and purging of nonhydrated grout (liquid
AV-202 that has not been exposed to water or moisture) from pumps,
fittings, and hoses can be accomplished with AV-208 (Technical Grade
Acetone). Although acetone is preferred, MEK or other solvents are
sometimes used. When using solvents for cleanup, extinguish all
sources of ignition in the area and observe proper precautionary
measures for handling such materials. If small component parts must
be cleaned of cured grout, it is best to disassemble and soak them in a
100% solution of AV-222 Grout Cleaner. (Always use polyethylene
plastic or steel containers for soaking).

Safety During Cleanup


Acetone is flammable and the precautions necessary for any flammable
material should be followed. Since grout compound which comes into
contact with clothing cannot be removed, rain gear or disposable
coveralls are highly recommended. Hats or hoods help keep the
material from dripping into the hair during overhead application.
Handling and Storage of AV-202 Multigrout
Care must be taken in handling and storage of AV-202 Multigrout. The
material is sensitive to moisture and moderately sensitive to high
storage temperatures. Optimum storage is 40-60F under fairly dry
conditions. Storage temperature should not exceed 80F. Properly
stored, the material should have a useful shelf life of two years. Once a
container has been opened, the useful life of the material is reduced.

Safety Procedures
Please refer to the Avanti AV-202 Multigrout MSDS available online at
www.avantigrout.com.

Exposure
AV-202 Multigrout in nonhydrated or liquid form may cause skin and eye
irritation following direct contact. If AV-202 comes in contact with skin,
it should be washed off with soap and water. Material getting into the
eyes must be flushed out immediately with water and a physician
should be consulted. AV-202 Multigrout should not be ingested.
Before eating, smoking, or drinking liquids, remove protective clothing
such as gloves and coveralls, wash hands with soap and water and
stand away from the immediate work site. DO NOT SMOKE while
working with AV-202 Multigrout. If respiratory difficulties are encountered when working with AV-202 Multigrout, obtain medical attention.
Users should avoid excessive exposure to vapors and keep the work
area sufficiently ventilated to avoid exceeding the toluene diisocyanate
Threshold Limit Value (TLV). Gloves, goggles, respirator, and protective
clothing are recommended when working with this product.

Ventilation
Ventilation is an important aspect of project planning. Small amounts of
toluene diisocyanate (TDI) may be present. A small segment of the
population may be more sensitive to TDI than the norm. A respirator
equipped with an organic vapor cartridge should always be available
and ventilation augmented by blowers or fans when appropriate.

AvantiGrout stops leaks. Permanently.


AL-02P2

AL-02P4

AL-02P5

AV-202 Multigrout Page 04

AV-202 Multigrout Page 02

Introduction

General Information

AV-202 Multigrout is a chemical grout system of water-soluble


hydrophilic polyurethane pre-polymers. Multigrout reacts freely with
water to form a strong film, gel or foam according to the mix design
requirements of the application. This capability makes Multigrout ideal
for use as a remedial water stop in a wide range of construction
applications.

For example, by combining Multigrout with water in a ratio of


one part Multigrout and 1 to 5 parts of water, the resulting foam might
be used to fill an abandoned pipeline. With a greater ratio of water to
Multigrout, perhaps in the range of 1 part Multigrout to 10 parts of
water, the product can be injected into a subsurface structure to seal
cracks in concrete. By increasing the water ratio even higher to
perhaps a 1 to 20 ratio of Multigrout to water, the resilient gel can be
effectively used as an impermeable barrier for other applications.

continued.

Instructions

AV-202 Multigrout Page 05

Estimating AV-202 Application Req.

continued.

continued.

Cleanup Procedures

continued.

Table Six:

As the ratio of water to Multigrout increases, the viscosity of the mixture


decreases. The nature of a particular application dictates the proper
ratio of Multigrout to water and experience is the best teacher for how to
choose the correct mixture. An operator must always bear in mind that
each application is unique and requires planning. The ideal goal should
always be a balance between an initial product viscosity that makes
placement effective and easy and a final product that will accomplish
the job at hand.
An outstanding feature of AV-202 Multigrout is its adaptability to any of
several water stop requirements. In an application needing a foam, for
example, the product is appropriate as well as another application
where a resilient gel is required. The property of the end product is
easily controlled by any application program. Furthermore, AV-202
Multigrout can also be altered during a grouting program. For example,
a quick foam can be formed initially and later backed up with a dense,
strong gel, all from the same basic product. Complex grouting
applications can often be simplified by the use of AV-202 Multigrout.

AV-202 Multigrout has a strong affinity for water. Although normally


not required, standard static mixers may be used. Upon curing, the
gel can contain many times its own volume of water. The mixture of
AV-202 Multigrout and water is initially low in viscosity and can be
injected under pressure to seal voids, fissures or cracks. Once the
gel has cured, it is resistant to water, thus reducing permeability and
forming an effective water shut off system. The cured grout also
increases the strength of the soil mass and consolidates the soil.

When AV-202 Multigrout is mixed with a small amount of water, a


reaction proceeds through two stages: foam stage and cure stage.

Ratio Range
Water : Multigrout

General Properties

50% to 20%
12% to 9%
6% to 5%
4% to 3%
2% to 1%

1:1 to 5:1
7:1 to 10:1
16:1 to 20:1
25:1 to 49:1
50:1 to 100:1

Foam
Expansive Gel
Soft Gel
Very Weak Gel
Emulsion

Gel time is defined as the time interval from initial mixing of AV-202
to the point where the blend viscosity is too high for gravity flow.

Gel time is controlled primarily by two factors:


1. Water temperature
2. Water : AV-202 ratio

Due to the adaptability of AV-202


Multigrout, the product is appropriate for
many different waterproofing and sealing
problems. It may be injected with a
positive displacement pump or used
with AV-219 (Oakum) for large cracks or
joints and placed by hand. The ability to
control the physical properties of the
final product gives the applicator a tool
for a wide variety of grouting programs.
For injection placement, the best
equipment is a positive displacement
pump such as the Graco Airless Sprayer.

Lower water temperatures and higher water to AV-202 ratios give


longer gel and tack free times. Gel times may also vary slightly with
the age of the AV-202 and chemical content of the water.
Table Five depicts the relationship between gel time and
concentration of Multigrout with gel time measured at 3 levels of
temperature in the aqueous solution.

Table Five:
Water : AV-202

Both stages of the grout must be understood and controlled to


obtain good results. The ambient temperature of the grout is the
primary variable that affects foam and cure times.

If unrestrained, the material may expand up to ten times the original


unreacted volume of grout and water. Unrestrained expansion,
however, results in a foam of low density. A compacted foam is more
desirable for most applications and fillers or reinforcements such as
oakum may be used to provide acceptable density.
Following the foam stage is the cure stage. During the cure stage,
the grout solidifies and forms a cellular rubber gasket (reinforced by
oakum if it has been added) which can withstand a water pressure
test. After placement and the foam stage, the grout will continue to
cure over the next several hours; however, within five to ten minutes
it has achieved sufficient strength to form a serviceable water barrier.

AV-202 : Water Ratio

Foam Time in Minutes at 78F

10:1
9:1
8:1
6:1
4:1
2:1
1:1

18.00
14.25
11.00
8.00
4.25
2.50
1.50

Data shows that the permeability of a soil grouted with AV-202 in gel
form is a function of the extent that voids are filled with grout.
Values in the 10-7 to 10-9 cm/sec range should be obtained when
voids are essentially full of grout using the constant head
permeability test method (ASTM D-2434).

Other factors may affect quantities required. These figures are intended
only as a guide.

Normally an overnight soak will dissolve most deposits and sufficiently


soften them for easy removal.

In joints, the primary factor influencing the quantity of AV-202 Multigrout


required to seal a given joint is the size of the joint gap. The amount of
AV-202 required will be less if old joint compounds still partially fill the
joint. As a rough rule of thumb, one fluid ounce of AV-202 will be
required per lineal inch of joint having a gap of one inch between the bell
and spigot.

To clean the entire grouting system, flush grout from system with up
to 5 gallons of AV-208 (Technical Grade Acetone). Pump until
acetone runs clean. DO NOT REUSE.

Actual examination of joint conditions, coupled with considerable


experience, is necessary to accurately estimate grout quantities. This is
particularly true for sealing large diameter pipe joints as shown in
Figure 1. In some instances, special equipment and techniques can be
employed to reduce material quantities required without affecting the
quality of the seal. Project planners are strongly encouraged to consult
with an approved applicator of Avanti products or an experienced
grouting contractor when preparing material cost estimates.

Estimating AV-202 Application Requirements

Ratio

Temperature ( F )

68

80

86

2:1
5:1
8:1
10:1
12:1
14:1
16:1
18:1
20:1

1.00
1.50
2.05
2.75
3.30
4.75
6.25
10.50
15.00

0.50
1.00
1.50
2.00
2.50
3.50
4.60
7.70
11.00

0.35
0.90
1.25
1.40
1.80
2.50
3.20
5.40
7.80

Table Six illustrates the relationship between foam time and


concentration of Multigrout. Foam time was measured at 78
temperature in the aqueous solution. The foam requires approximately
an equal amount of time to reach a tack free condition after its
initial set.

Application of AV-202 Multigrout

AV-202 is designed to be used by qualified applicators with the


proper equipment. Grouting equipment for the application of this
product is available from Avanti International.

The EGP Technique


The Expanded Gasket Placement Technique (EGP) is the process
whereby jute strips, soaked in AV-202, are then packed around various
types of pipe to achieve a very effective seal. For further information
concerning EGP, consult the Avanti EGP brochure, which can be
downloaded from the Avanti website at www.avantigrout.com.

60
50
40
30
20

0
36

Set Time in Minutes

Within 15 to 45 seconds after mixing, depending on mix ratios and


the temperature of the grout and mix water, the material will begin to
foam. The viscosity is such that the grout will not readily flow out of
the point of placement, i.e., into the pipe or the soil outside of the
pipe.

General Information

AV-202
Multigrout

AV-202 Multigrout is often used for grouting joints and repairing leaks
in large sanitary and storm sewer pipes by forming a flexible gasket or
plug in the flowing water path. In an uncured form, AV-202 is a
viscous liquid similar in appearance to common honey. When mixed
with a small amount of water, however, the grout expands and rapidly
cures to a tough, flexible, cellular rubber that is essentially unaffected
by sewer environments.

Percentage
Multigrout : Total Volume

Grout - pounds

The form of the final product, whether it is film, gel or foam, is controlled
by the ratio of water to AV-202 Multigrout. For example, a mixture of 1
part Multigrout and from 1 to 5 parts water will produce a product with
the general properties of a foam. A mixture of 1 part Multigrout and
approximately 7 to 10 parts water will result in a resilient gel. A mixture
of 1 part Multigrout and 16 to 20 parts water will result in a soft gel.
Ratios of 1 part Multigrout and 25 to 30 parts water create a very soft
gel. The specific physical properties of AV-202 Multigrout, when
combined with water in various ratios, are depicted later in this manual.

Table Four:

42

48

60

72

84

96

108

120

Pipe Diameter - inches

Figure 1: AV-202 Multigrout required for large diameter pipes.


Note: Refer to Avanti Internationals Large Diameter Pipe Sealing
Specification available online at www.avantigrout.com.
The quantities of AV-202 Multigrout required to rehabilitate or repair
concrete pipe joints of various diameters are shown in Figure 1. These
quantity estimates are based on actual field experience but may vary
slightly in the smaller diameter pipe and substantially in the larger
diameter pipe.

Some factors which may affect the quantity of AV-202 required are:
1. Original gasketing materials remaining in the joint.
2. Open or off-set condition of the joint.
3. Severity of infiltration or exfiltration at the joint.
4. Type and condition of grouting equipment to be used.
5. Application method used.

The V-PAT Technique for Sealing Joints and Cracks


The Variable Pressure Application Technique (V-PAT) can be used to
apply pure AV-202 Multigrout resin in both cracks and expansion joints.
The methods used for these two water control problems are somewhat
different, but the basic steps are the same. The procedures for sealing
cracks and joints by the V-PAT method may be found on the Avanti
website at www.avantigrout.com.

Cleanup Procedures
Cleaning
Most day-to-day cleanup and purging of nonhydrated grout (liquid
AV-202 that has not been exposed to water or moisture) from pumps,
fittings, and hoses can be accomplished with AV-208 (Technical Grade
Acetone). Although acetone is preferred, MEK or other solvents are
sometimes used. When using solvents for cleanup, extinguish all
sources of ignition in the area and observe proper precautionary
measures for handling such materials. If small component parts must
be cleaned of cured grout, it is best to disassemble and soak them in a
100% solution of AV-222 Grout Cleaner. (Always use polyethylene
plastic or steel containers for soaking).

Safety During Cleanup


Acetone is flammable and the precautions necessary for any flammable
material should be followed. Since grout compound which comes into
contact with clothing cannot be removed, rain gear or disposable
coveralls are highly recommended. Hats or hoods help keep the
material from dripping into the hair during overhead application.
Handling and Storage of AV-202 Multigrout
Care must be taken in handling and storage of AV-202 Multigrout. The
material is sensitive to moisture and moderately sensitive to high
storage temperatures. Optimum storage is 40-60F under fairly dry
conditions. Storage temperature should not exceed 80F. Properly
stored, the material should have a useful shelf life of two years. Once a
container has been opened, the useful life of the material is reduced.

Safety Procedures
Please refer to the Avanti AV-202 Multigrout MSDS available online at
www.avantigrout.com.

Exposure
AV-202 Multigrout in nonhydrated or liquid form may cause skin and eye
irritation following direct contact. If AV-202 comes in contact with skin,
it should be washed off with soap and water. Material getting into the
eyes must be flushed out immediately with water and a physician
should be consulted. AV-202 Multigrout should not be ingested.
Before eating, smoking, or drinking liquids, remove protective clothing
such as gloves and coveralls, wash hands with soap and water and
stand away from the immediate work site. DO NOT SMOKE while
working with AV-202 Multigrout. If respiratory difficulties are encountered when working with AV-202 Multigrout, obtain medical attention.
Users should avoid excessive exposure to vapors and keep the work
area sufficiently ventilated to avoid exceeding the toluene diisocyanate
Threshold Limit Value (TLV). Gloves, goggles, respirator, and protective
clothing are recommended when working with this product.

Ventilation
Ventilation is an important aspect of project planning. Small amounts of
toluene diisocyanate (TDI) may be present. A small segment of the
population may be more sensitive to TDI than the norm. A respirator
equipped with an organic vapor cartridge should always be available
and ventilation augmented by blowers or fans when appropriate.

AvantiGrout stops leaks. Permanently.


AL-02P2

AL-02P4

AL-02P5

AV-202 Multigrout Page 06

AV-202 Multigrout Page 03

Specific Description of AV-202 Multigrout

Instructions for Using AV-202 Multigrout

Safety Procedures

AV-202 Multigrout is a hydrophilic polymer. The uncured material is a


caramel colored, translucent liquid with a viscosity in the 2500
centipoise range at 86F. At workable water to polymer ratios, however,
the viscosity can be adjusted to approach the 15 to 30 centipoise range.
AV-202 contains non-volatile materials constituting almost 100% of its
total weight.

Although the AV-202 Multigrout pre-polymer is a relatively thick material,


it is easily handled with commercially available positive displacement
pumps. AV-202 Multigrout is designed to cure with water, and may
absorb large quantities into the reaction mass. The ratio of water to
AV-202 Multigrout chosen depends upon the application. For most
applications which require the use of gels, the water to AV-202
Multigrout ratio should be in the range of 10:1 to 15:1 by volume.

Summary of Handling Precautions


1. Wear goggles and rubber gloves in handling and application
operations.
2. Keep away from heat and open flame during storage and use.
3. Ventilate sufficiently and use respirator, especially for operations
in a confined space.
4. If skin or mucous membrane is contaminated with Multigrout or
its solutions, wash thoroughly with plenty of water. In case
of eye contact, wash immediately with plenty of water and boric
acid solution, and seek medical attention.

When mixed with a specific quantity of water, the material can expand
10 to 12 times its original volume and cure to a tough, flexible and
elastomeric condition. After completely curing, the AV-202 may exhibit
strength properties of up to 80 psi tensile and 500% elongation.

Physical Properties of AV-202 Multigrout


The physical properties of monolithic films prepared with Multigrout
are summarized as follows:

Table One:
Water : AV-202
Ratio

% AV-202*

20:1
10:1
5:1

5%
10%
20%

Tensile Strength

Elongation

Tear Strength

(kg/cm2)

(%)

(kg/cm2)

100
150
600

15
18
20

120
100
46**

* Concentration by weight of Multigrout in the aqueous solution


used to prepare a monolithic film.
** A foamy film is obtained when concentration is higher than 20%,
i.e., less than five parts of water to one part of AV-202 Multigrout.

Higher ratios (i.e., greater than 15:1) give lower initial viscosities and
longer gel times but reduce the unconfined compressive strength of the
consolidated material in the grout zone. Such high ratios are primarily
used for short-term erosion control of surface soils.

During the initial reaction stage of Multigrout with water, amines and
carbon dioxide are generated by a reaction with water in the soil or
water injected with the grout pump at the site of the leak to be sealed.
Then, the resultant amines react quickly with an isocyanate group to
form compounds with a three-dimensional structure cross-linked with
urea and biuret linkages. These compounds form a gel which is
insoluble in water.

Table Two:
Chemical Properties

Flash Point
Corrosiveness
Reactivity

UL Water Product Certification


ANSI/NSF Standard 61 encompasses
products that come in contact with
drinking water and/or drinking water
treatment chemicals. Products covered
by this standard include:
EPH

ANSI/NSF 61
DRINKING WATER SYSTEM COMPONENTS
88NN

1. Pipes and related products


2. Barrier materials, i.e., coatings, linings
3. Joining and sealing materials, i.e.,
adhesives, gaskets

Warranty Statement

The initial mixed viscosity of the water to AV-202 Multigrout blend is


important in determining the soils that can be penetrated and pumping
pressure required. With the AV-202 Multigrout system, the initial mixed
viscosity is dependent primarily on the water to AV-202 Multigrout ratio
and water temperature.

The data, information, and statements contained herein are believed


to be reliable, but are not construed as a warranty or representation
for which Avanti International assumes any legal responsibility. Since
field conditions vary widely, users must undertake sufficient verification and testing to determine the suitability of any product or process
mentioned in this or any other written material from Avanti for their
own particular use.

The linearity of the rate at which the viscosity of the mixed grout
increases from the time of mixing up to gelation is a second important
factor in determining the degree and types of soil that can be
penetrated. With the AV-202 Multigrout, the viscosity remains low for
the initial 60 to 70% of the gel time and then increases rapidly as the
blend approaches gelation.

NO WARRANT OF SUITABILITY OR FITNESS FOR A PARTICULAR


PURPOSE IS MADE.

The relationship between temperature and viscosity of AV-202


Multigrout pre-polymer (prior to mixture with water) is illustrated in
Table Three.

AV-202 Multigrout

Nothing in this or any other document from Avanti International is to


be taken as permission, inducement, or recommendation to practice
any patented invention without a license.

AV-202

Table Three:
Temperature

Chemical Properties

continued.

Technical Manual

Viscosity

CPS

104
95
86
77
68
59
50

40
35
30
25
20
15
10

500
1000
2500
3500
5500
9000
14000

Multigrout

EPH

ANSI/NSF 61
DRINKING WATER SYSTEM COMPONENTS
88NN

The relationship between the concentration of Multigrout


(water/polymer ratio) and the properties of the resultant material is in
Table Four.

AvantiGrout stops leaks. Permanently.

200C
Non-corrosive
Reacts readily with water

Technical Manual

822 Bay Star Boulevard


Webster, Texas 77598
800 . 877 . 2570
281 . 486 . 5600

Copyright 2005 Avanti International

www.avantigrout.com
AL-02P3

AL-02P6

www.avantigrout.com
AL-02P1

AvantiGrout Product Guide

Hydrophobic Foams - Hydrophylic Foams

Contains no phthalates, solvents, VOCs, CFCs or VFCs

HYDROPHOBIC FOAMS

Viscosity

AV-248 Flexseal/AV-249
Low cP 150-250 cP

Standard 550-830 cP
Expansion: 400-600%
High cP 1200 200 cP
Ratio: See TDS
AV-260 Fusion Grout/AV-261
300-400 cP

Expansion: 1500-2000%
Ratio: See TDS
AV-275 Soilgrout/AV-276

Expansion: 1500-2000%
Ratio: See TDS

120-220 cP

AV-278 Low Vis Hydro/AV-279

Expansion: 1500-2000%
Ratio: See TDS

25-100 cP

Description

General Uses

Packaging (net wt.)

Single component, moisture activated


MDI-based hydrophobic resin that withstands wet/dry cycles. Forms a resilient,
impermeable, flexible foam.
Single component, moisture activated
MDI-based hydrophobic resin that withstands wet/dry cycles. Forms a resilient,
impermeable flexible foam.
Single component, moisture activated
MDI-based polyurethane resin designed
to bind together and waterproof loose
granular soils. Withstands wet/dry cycles.

Above and below ground structures


Pipe annulus between slip-liners
Fine cracks or joints in concrete
Expansion joints

5-Gallon Pail
Catalysts: Low cP: 32 oz.
Standard: 16 oz.
High cP: 25 oz.

Above and below ground structures


Pipe annulus between slip-liners
Fine cracks or joints in concrete

5-Gallon Pail
Catalyst: 32 oz.

Soil stabilization
Fill voids
Stop leaks in below-grade structures
Probe and curtain grouting

5-Gallon Pail
Catalyst: 32 oz.

Single component, MDI-based polyurethane resin that uses moisture as an


initiator. Designed with soil permeation in
mind. Withstands wet/dry cycles.

Soil stabilization
Fill voids
Stop leaks in below-grade structures
Probe and curtain grouting

5-Gallon Pail
Catalyst: 64 oz.

AV-280 Hydrofoam/AV-281

Expansion: 1500-2000%
Ratio: See TDS

1700-2200 cP Single component, MDI-based polyurethane resin that uses moisture as an


initiator. Designed to not easily wash away
in high volumes of water.

Fill voids via curtain or probe grouting


Seal annular spaces
Slope stabilization
Stabilization of coarse soils or gravel

5-Gallon Pail
Catalyst: 13 oz.

AV-290 Fast-Set

Expansion: 1500-2000%
Ratio: No Water Required

A 50-150 cP Dual component, MDI-based hydroB 100-300 cP phobic polyurethane resin designed to
fill large voids where high water flow is
present and reacts in seconds.
Single component, polyurethane designed
20-30 cP
to permeate and stabilize various types
of soil. Increases load bearing capacity
of permeable soil by increasing cohesion
between soil by filling void areas.

Manholes
Storm and drain culverts
Cut off high water ows

5-Gallon Pail Kit


Dual Cartridge

Probe grouting
Tube-a-manchette grouting
Soil Stabilization

5-Gallon Pail
Catalyst: 25 oz.

3200-6000 cP ANSI/NSF 61, UL Certified, Potable


water. Single component, moisture activated, versatile and flexible polyurethane
foam or gel. Designed for sealing active
water leaks in large concrete structures.
Excellent bonding capabilities.

Large cracks or joints in concrete


Dams and reservoirs
Precast structures
Manhole and pipe penetrations
EGP (Oakum Soakum) Technique
Below grade expansion joints

5-Gallon Pail
1-Gallon Container
Cartridge

AV-550 Soil Strengthener/AV-551

Expansion: 1500-2000%
Ratio: See TDS

HYDROPHILIC FOAMS
AV-202 Multigrout*

Expansion: 400-600%
Water to Resin Ratio - 1:1-12:1
AV-202-LV Multigrout LV

Expansion: 400-600%
Water to Resin Ratio - 1:1-10:1
AV-315 Microfoam

650-800 cP

Low viscosity version of AV-202. Single


component, polyurethane injection resin
that cures to form a resilient and flexible,
yet tough, closed-cell foam.

Large cracks or joints in concrete


Dams and reservoirs
Precast structures
Manhole and pipe penetrations

5-Gallon Pail
1-Gallon Container
Cartridge

50-200 cP

Single component, moisture activated


polyurethane injection resin that cures
to a flexible foam. Designed for sealing
active water leaks in very ne cracks or
joints in below-grade structures.

For use in below grade structures


Stop leaks in mines, tunnels and subways
Fine cracks or joints in concrete

5-Gallon Pail
1-Gallon Container

350-750 cP

ANSI/NSF 61, UL Certified, Potable


water. 100% MDI-based single component, moisture activated resin that cures
to a flexible foam. Designed for sealing
active leaks in below grade structures.

Medium cracks or joints in concrete


Manholes and pipe penetrations
Tie-backs and slurry walls

5-Gallon Pail
1-Gallon Container

350-750 cP

Cracks or joints in concrete


ANSI/NSF 61, UL Certified, Potable
Manholes and retaining walls
water. Single component, moisture
Applications involving plastic
activated polyurethane injection resin.
Designed for sealing active water leaks in
cracks in below-grade structures.

Expansion: 400-600%
Water to Resin Ratio: 1:1
AV-330 Safeguard*

Expansion: 400-600%
Water to Resin Ratio: 1:1
AV-333 Injectaflex
Expansion:400-600%
Water to Resin Ration: 1:1

5-Gallon Pail
1-Gallon Container
Cartridge

* Non-potable version available (NTP)

697 Main Street | Tullytown, PA 19057 | P: 800.822.2565 | F: 215.547.3366 | www.A-LOK.com

AvantiGrout Product Guide

Cementitious Grout - Chemically Reactive Gels - Urethane Gels


Elastomers - Auxiliary Products
Contains no phthalates, solvents, VOCs, CFCs or VFCs

CEMENTITIOUS GROUT
Ultrafine Cement (avg. 3.5 microns)

Expansion: None
Ratio: See TDS
Microfine Cement (avg. 7 microns)

Expansion: None
Ratio: See TDS

Viscosity

Description

General Uses

Packaging (net wt.)

Stabilize weak soil


Seal seepage in mines, dams and tunnels
Contain hazardous waste
Oil well squeeze cementing

44 lb. bag (54 bags/pallet)


Super sack - 2,000 lbs.
Pneumatic Truck

Stabilize weak soil


Seal seepage in mines, dams and tunnels
Contain hazardous waste
Oil well squeeze cementing

44-lb. bag (54 bags/pallet)


Super sack - 2,000 lbs.
Pneumatic Truck

Thinnest resin on the market with control1-2 cP


(in solution) lable gel times from seconds to hours,
creating a long-lasting water barrier and
superb soil stabilization.Tested and approved for the U.S. DOE by Oakridge
National Laboratory.
Extremely low viscosity resin with gel
1-2 cP
(in solution) times from seconds to hours, creating a
long-lasting water barrier and superb soil
stabilization.

Seal mainlines/laterals/manholes
Contain hazardous waste
Waterproof underground structures
Soil stabilization
Waterstop: tunnels, dams, mines

Liquid
Tote - Net wt: 2,300 lbs.
Drum - Net wt: 130 lbs.
Granular
50 lb. bag (24 bags/pallet)

Sewer lateral/joint sealing/manholes


Contain hazardous waste
Waterproof underground structures
Soil stabilization
Waterstop: tunnels, dams, mines

Tote - Net wt: 2,430 lbs.


Drum - Net wt: 135 lbs.

3-4 cP
(in solution)

Sewer lateral/joint sealing/manholes


Contain hazardous waste
Waterproof underground structures
Soil stabilization
Waterstop: tunnels, dams, mines

Tote - Net wt: 2,250 lbs.


Drum - Net wt: 130 lbs.

N/A

N/A

Smaller particle size penetrates fine


fractures and silty/clay soils. Low internal
cohesion means better permeation and
less drilling costs. Developed for the
U.S. DOE by Sandia National Laboratories.
Smaller particle size penetrates fine
fractures and silty/clay soils. Low internal
cohesion means better permeation and
less drilling costs.

CHEMICALLY REACTIVE GELS


AV-100 Chemical Grout
Liquid and Granular
Expansion: None
Ratio: 1:1
AV-118 Duriflex
Expansion: None
Ratio: 1:1
AV-160 SuperGel
Expansion: Slight
Ratio: 1:1

Extremely low viscosity acrylate resin with


adjustable gel times. Creates a long-lasting water barrier and superb soil stabilization. Non-Acrylamide product.

LIFTING FOAMS
AV-600 SureLift/Fast and Slow Version

Expansion: 1500-2000%
Ratio: 1:1

A 475 cP
B 200 cP

Dual component, pour-in-place hydropho- Lift concrete slabs


bic urethane foam system. Low viscosity Fill voids
design allows material to be blended with Soil strengthening
typical/hand mixers.

Tote-A: 2,585 lbs.| B: 2,230 lbs.


Drum-A: 517 lbs.| B: 446 lbs.
Pail-A: 42 lbs. | B: 42 lbs.

URETHANE GELS
AV-254 Gelseal

Expansion: Slight
Water to Resin Ratio: 8:1
AV-350 Multigel

Prepolymer resin with excellent perme10 cP


(in solution) ation properties when injected in water.
Cures to create an effective water barrier
while providing soil stabilization.

Waterproof/stabilize soil around:


Manholes
Pipe joints
Tunnels and dams
Underground structures

5-Gallon Pail

Prepolymer resin with excellent perme10 cP


(in solution) ation properties. Has added benefit of
containing dimethyl ketone (acetone).

Waterproof/stabilize soil around:


Manholes
Pipe joints
Tunnels and dams
Underground structures

55-Gallon Drum
5-Gallon Pail

1400 cP Dual component elastomer resin. Cures


(A/B mixed) to a pliable rubber in 4-minute and
34-minute versions. AV-201 Primer is
recommended.

Rubber coating
Fill cracks
Fill joints
Sprayable, injectable, trowelable versions

55-Gallon Drum
5-Gallon Pail
Dual Cartridge

Expansion: Slight
Water to Resin Ratio: 8:1

ELASTOMERS
AV-200 Duraset

Expansion: None
Ratio: See TDS

AUXILIARY PRODUCTS
Injectors & Couplers
Pumps & Hoses
Injection Hose Kit
Oakum
Resin Rod
Catalysts

PACKAGING OPTIONS

Personal Protective Equipment (PPE)


Cured-Resin Remover
Latex
Dyes
Root Inhibitor
Technical-Grade Acetone

697 Main Street | Tullytown, PA 19057 | P: 800.822.2565 | F: 215.547.3366 | www.A-LOK.com

The Company With Connections

FLEX-LOK STEP INSERT


A series of polypropylene inserts for the purpose of securing steps in
the wall of a precast concrete manhole or other concrete structure.
BENEFITS:
Placement of insert is done at the time of manufacture.
Concrete wall remains watertight.
Guaranteed alignment and projection of steps.
Precise hole to accept step shank.
Interference fit makes installation of step rapid and simple.
Polypropylene offers excellent chemical resistance.
RIBS SECURE STEPS
IN PLACE

ROUND INSERTS

SQUARE INSERTS

SPECIFICATIONS:
Insert meets the requirements of ASTM C-478 section 16.
Exceeds the performance test procedures of ASTM C-497 section 10.

697 Main Street P.O. Box 1647 Tullytown, PA 19007


Toll Free: 1.800.822.2565 Phone: 1.215.547.3366
Fax: 1.215.547.5260 www.a-lok.com

Big boxes, big seals


DIXIE CONTRACTOR, August 5, 1991

Custom design helped a drainage


project to a successful completion at
Dixie Landings, a Florida
development.

Florida is a land of superlatives world's brightest sunshine, world's most beautiful beaches, and on and on.
Now, thanks to recent construction at the Dixie Landings Resort, Florida claims another record too. It's now the site of the world's largest
flexible pipe to manhole seal.
Construction began last year on the Dixie Landings Resort Community Phase 1. The project in Lake Buena Vista, Fla., was designed by the
Boyle Engineering Corporation of Orlando.
Phillips & Jordan Incorporated of Knoxville, Tenn., submitted the low bid for Phase I of the project. Construction of the storm drainage for this
phase of the project involved the installation of 184 storm sewer structures and more than 20,500 linear feet of storm drainage pipe in sizes
of 8 in. PVC up to 84 in. RCP. The work involved depths exceeding 14 vertical feet.
Plans called for phase I of the project be constructed on a very tight construction schedule which required the storm sewer structures to be
delivered, excavated, installed and backfilled within 90 days from the first shipment. Phillips &Jordan choose Atlantic Concrete Products of
Sarasota, Fla. , as the supplier of the precast drainage structures and specified that the A-LOK STM Connector manufactured by ALOK
Products of Tullytown, Penn., be installed in every location possible.
Included in the 184 storm drainage structures were five special structures to accommodate direction changes of the 1040 lineal feet of 84 in.
reinforced concrete pipe. Reinforced concrete pipe for this project was supplied by Joelson Concrete Pipe Company. These five structures
were in excess of 13.5 ft. deep and were located in an area with a water table that was approximately one foot below finished grade.
Phillips & Jordan and their project manager Jerry Martin were concerned with the installation time and the watertightness when using structures with conventional grouted pipe connections. Atlantic Concrete Products solved this problem by custom designing five structures with
the pipes entering on a flat wall surface. These were rectangular, trapezoidal and pentagonal structures designed to accommodate the large
84 in. concrete pipe while keeping the lifting weight minimal.
Atlantic Concrete then asked ALOK Products to furnish the largest rubber storm pipe connector to date. The A-LOK STM Connector was
designed to accommodate the 84 in. reinforced concrete pipe with a 100 in. outside diameter. This would speed the installation and ensure
watertightness.
A-LOK met the challenge and was able to design and furnish A-LOK STM mandrels and gaskets to meet the precaster's delivery schedule.
The first structure for the 84 in. line was delivered last May, and within 90 minutes the influent and effluent pipes were installed and the structure ready for backfill. Overall, Phillips &Jordan was able to complete the installation in 75 days, 15 days ahead of schedule.

Flexible Storm Sewer Connector Introduced in Orlando


The largest application of a flexible pipe-to-manhole storm sewer
connector in Florida was introduced by Atlantic Concrete Products,
Inc. to the Orlando area in the early 90's. The application
consisted of 54" through 66" concrete pipe installed into 6' through
8' structures using the A-LOK STM flexible connector.
The A-LOK STM Connector was designed by A-LOK Products,
Inc. of Tullytown, Pennsylvania specifically to give long-term
protection against water infiltration and soil erosion into storm
sewer systems. It provides for more economical construction by
elimination the costly mortaring operation; prevents road
settlement due to sub-soil infiltration into the system and enables
normal traffic patterns to be re-established more quickly because
backfill can be affected immediately. The system is also effective
in reducing long term maintenance costs.

A 6 ft. x 7 ft. Type "J" Box of 54 in. RCP


Pipe installed into A-LOK STM Gasket.

The Wesmere-Phase I project is located in Orange County and is owned by Arvida/JMB Partners-II Inc. The
system was designed by Bowyer-Singleton and Associates and installed by Premier Development of Central
Florida.
The project includes 87 storm structures varying in depth from 4 feet to 14.5 feet. The structure sizes range
from 4 diameter through 8 diameter round and from 36 to 80 square. All storm sewer structures were
manufactured by Atlantic Concrete Products to meet Florida D.O.T. specifications. The pipe was
manufactured by Hydro-Conduit Corporation and ranges in size from 15 RCP through 66 RCP.
The A-LOK STM storm sewer gaskets were placed in any structure where the invert elevation and the pipe
angle permitted the use of the gasket. Some structures were manufactured using one gasket and one hole.
Steve Sowards of Premier Development felt that he was getting a better job by at least having the single
gasket in the structure.
In addition to the storm structures, there are also 54 sanitary manholes and a lift station on the project. The
depth of the sanitary sewer manholes were supplied with precast inverts and the A-LOK pipe-to-manhole
sanitary connector. In order to increase efficiency, the drop manholes were built with precast
drop connections and precast drop riser sections were utilized.
For more information, please contact A-LOK Products.
Reprinted from: The Florida Specifier

Dura-Plate 100 Manhole Liner


Corrosion Resistant Sewer Liner
Assures Long Services Life

A state-of-the-art corrosion resistant plastic liner, introduced by Atlantic Concrete Products, Inc. is
designed to line concrete sewer structures for compatible service life equal to PVC pipe or PVC lined pipe.
Dura-Plate 100 Liner is specifically designed for use in sanitary manholes and may soon replace
ineffective interior coatings and eliminate most of the field labor and human error common with other lining
methods. This will enable engineers to design with standard walls, since it is more economical to prevent
deterioration than to design for it with additional wall thickness (sacrificial concrete).
The liner is made of semi-rigid thermo plastic and is formed to fit the manhole contour. Ribs and formed
into the sheet to be integrally and securely cast into the concrete structure.
This product culminated ten years of research and development by Atlantic Concrete working jointly with ALOK Products, Inc. to create a structure that will perform and endure in the Florida climate. The liner
assures long service life under severe conditions being resistant to H2S acids, alkalis and salts which attack
sewer systems.
Atlantic concrete is one of the leading producers of underground wastewater structures in the Eastern
United States and A-LOK Products is nationally recognized as a leader in engineering, research and
development of innovative watertight connectors and other rubber and plastic accessories for the
wastewater industry.
A-LOK Products, Inc. manufactures a full line of: pipe-to-manhole flexible connectors; safe, non-leak lift
devices; damage resistant end joints; watertight joint gaskets; precast outside drops and corrosive
resistant PVC liner.
For more information please contact A-LOK Products, Inc.

Reprinted from: The Florida Specifier

APPLICATION DATA SHEET

#3 BAR DIAMETER

NOMINAL DIAMETER/AREA
10 mm (71.26 mm2)
3/8 in (.110 in2)

LENGTHS

Up to 20 ft

WEIGHT

.09 lbs/ft

GUARANTEED TENSILE STRENGTH


ASTM 7205
999 MPa
145 ksi

ULTIMATE TENSILE LOAD ASTM 7205


87.5 kN
19,675 lbs

TENSILE MODULUS OF ELASTICITY


ASTM 7205
46 GPa
6.7 x 106 psi

GUARANTEED TRANSVERSE
SHEAR CAPACITY ASTM 7617

HERE TO STAY
APPLICATIONS

products. These components independently have withstood the test of time,


and Neuvokas is combining them with a proprietary process that allows
GATORBAR to be produced at a high rate of speed. This high rate of speed
enables PRICE PARITY WITH STEEL!
Neuvokas has completed three initial tests at independent universities that
show GATORBAR meets and exceeds the applicable ACI/CSA standards.
Neuvokas is working to complete the remainder of tests required to earn a
beginning sales in low risk areas such as slab-on-grade parking lots and other
similar structures for crack control.

PRODUCT FEATURES
GATORBAR OFFERS

Price parity - Its high tensile strength allows


#3 GATORBAR to replace #4 Black Bar at the same price.
Labor savings - Labor savings estimated at 1 man-hour
per ton of steel replaced.
Freight savings - Up to 75% Freight savings on truckload quantities.
Extended structure life - No rust high strength equals long life.

173 MPa
25.1 ksi

Reduced injury - Labor will carry and place 7X less weight per job,
reducing repetitive lifting injuries and other bodily strain.

MOISTURE CONTENT ASTM D570

CHAIR IT UP AS YOU WOULD STEEL,


TIE IT OFF AND POUR WITH CONFIDENCE.

< .5%

BOND STRENGTH ACI 440.3R B3


14.1 Msi
2,047 psi
4,519 lbs

FIBER CONTENT

80% by weight

CONTACT US
A-LOK Products, Inc
697 Main St. | PO Box 1647
Tullytown, PA 19007

(215) 547-3366
info@a-lok.com
www.a-lok.com