You are on page 1of 4

Central Tool Room & Training Centre

Bhubaneswar
Assignments on Latching
Assignment 1:Daw and design a lad.

.
(HINTS:-START-STOP).
Assignment 2:A conveyer C is to run when any of the four push button is
pressed. The conveyer is to stop when any one of the four feed back
comes to the plc from the physical site.
Assignment 3:Design and draw the schematic for conventional hardwired circuit that
will perform the following circuit function using break-make
pushbuttons:
Turn on light L1 when pushbutton pb1 is pressed.
Turn on light L2 when pushbutton pb2 is pressed.
Electrically interlock the pushbuttons so that L1 and L2 cannot both
be turned on at same time.
Assignment 4:-

Develop LAD logic for sequential control of two Motors. Two


motors (M1, M2) are to be separately started and stop from individual
start stop push button stations. Motor M2 can only be started when
Motor M1 starts. Once motor M2 starts it can be separately stopped but if
the stop push button for motor M1 is pressed then both the motor M 1&
M2 gets OFF. While running Motor M1 & M2 both if a common stop
switch is pressed it makes both the motor OFF.
Assignment 5:Motor starts in the forward direction (Contactor K1) when
the forward PB1 is pressed and motor runs in the reverse
direction (Contactor K2) when the reverse PB 2 is pressed. When
stop PB3 is pressed motor stops. The motor must be stopped
before changing the direction.
Assignment 6:In a factory control room there are two sensors entry sensor
and exit sensor at the door. When entry sensor senses a man at the
door it will send a signal to the indicator panel at the top of the door
glow a RED lamp and make a GREEN lamp OFF which was
previously ON. When the indicator becomes RED it will run the
motor in forward to open the door. When the door gets fully opened
and touches a limit switch the motor gets OFF. When exit sensor
senses the man at the door; it will send a signal to the indicator
panel to make the GREEN ON which was previously OFF and also
it makes the RED lamp OFF. When indicator panel becomes
GREEN it will run the motor in reverse to fully close the door and
when it touches another limit switch by closing then the motor gets
OFF.
Assignment 7:-

In a tank control system, when low level of the overhead tank is


sensed the motor gets on .The low level sensor remains in
glowing condition till it sense level high with a green indication
lamp to glow. When it sense high motor gets off. The green
lamp should glow till the low level is not sensed again. In
emergency an emergency stop PB is used.
Assignment 8:In a factory, there is a conveyer & it operates through a control
panel board. When we pressed the PB1, the conveyer is running
its full speed & a green bulb will glow on the panel board.
When we pressed the PB2, the conveyer is running its medium
speed & red bulb will glow on the panel board. When we
pressed the PB3, the conveyer is running its slow speed & a
yellow bulb will glow on the panel board. When we pressed
PB4, then all the process is stop.
Assignment 9:Draw your own logic