You are on page 1of 9

5/11/2016

aerospace

Rocket motor casing


Fuselage/wings
Interiors
Aircraft seats
Control surfaces

Sistemas Compuestos
POLIMERO REFORZADO CON FIBRA

marine

Power & sail up to


200 ft.

TENDONES DE ANIMALES
COMO REFUERZO DE FIBRA

ARCOS DE FLECHAS
CORTOS DE MAYOR ALCANCE REFUERZO DE FIBRA
USADOS POR ATILA DE CARBONO EPOWRAP SETMIX
CARBOWRAP REFUERZO DE FIBRA DE
SETMIX VIDRIO

1
5/11/2016

load the fibers, not the resin-1


LT/LT i n f u s i o n specific reinforcements

T T

T T

When load is applied fibers will try to form a straight line between load
points.

A woven fabric creates stresses where fibers cross over or under one another. This results
in the resin carrying a disproportionate amount of load and ultimately failing at loads
lower than its non-crimped counterpart.

Pound for pound, non-crimp laminates are up to 30% stronger compared to woven
laminates. The high resin content of the woven also lowers overall performance.
The smooth surface of the non-crimp fabric produces better inter-laminar bond between
layers (short beam shear). The coarse texture of the woven will form resin concentrations.

load the fibers, not the resin-2

Here is an example where loads were carried by the concrete instead of the steel reinforcing.
Insufficient hoop or 90 reinforcing caused catastrophic failure. As the column swayed, the
brittle concrete fractured exposing the axial reinforcing rods which alone could not resist the
compression load of the bridge deck. Additional hoop reinforcing would have maintained
integrity even if the concrete had fractured. The solution (right) included fiberglass collars
snapped over the columns to provide 90 or hoop strength, maintain integrity during seismic
activity and to compliment the axial steel rods.

USOS
1994 Northridge Earthquake Highway I5 collapse

2
5/11/2016

3
5/11/2016

MANERA CORRECTA DE PEGADO DE REFUERZO DE FIBRA

EPOFIX 300

CARBOWRAP

EPOFIX 300

EPOBILD
NIVELADOR

EPOFIX PRIMER

PROPIEDADES DE LA LAMINA

PROPIEDADES DE LA FIBRA EN SECO


Propiedades ASTM Valor tpico de ensayo.
Diseo: refirase a ACI
Resistencia ltima a
tensin en la direccin D-3039 877 kg/cm ancho
principal de la fibra 842 MPa Resistencia a Tensin 550,000 psi
3.79 MPa
38750 kg/cm 2

Elongacin a la ruptura Mdulo de Tensin 33.4 x 106 psi


D-3039 1.2 % 230 GPa
Modulo de Tensin
D-3039 69.6 GPa
Resistencia ultima a Elongacin a la rotura 1.8 %
tensin de la fibra a 90 D-3039 0 Densidad 1.76 g/cm 3
de la principal
Peso por m2 600 grs.

Espesor de la lamina Resistencia ltima a tensin 1290 kg/cm de ancho del refuerzo
(normalizada) 1.0 mm VCF - 1800

CARBOWRAP 600

METODO VALOR DE ENSAYO

RESISTENCIA A D-638 72.4 MPa

El Sistema Epowrap CFRP debe ser diseado


TENSION TIPO I 10,500 psi

(por un profesional calificado) para cumplir


MODULO DE D-638 3.18 GPa
TENSION TIPO I 461,000 psi

PORCENTAJE D-638 5.0 criterios de diseo especficos.


ELONGACION TIPO I El diseo debe cumplir con ICBO AC-125, y
RESISTENCIA A D-790 123.4 MPa ser basado en fuerza de tensin y
limitaciones de esfuerzo especificadas en ACI.
FLEXION 17,900 psi

MODULO DE FLEXION D-790 3.12 GPa


452,000 psi
Cada proyecto presenta parmetros nicos
que deben ser dirigidos.

PROPIEDADES DEL SISTEMA


EPOXICO

4
5/11/2016

VIGUETA 5X5 cms SIN ARMADURA + REFUERZO CARBOWRAP SETMIX

Falla del hormign

ENCAMISADO TOTAL CON


FIBRA DE CARBONO

PUENTE AMBI
ENCAMISADO
HORIZONTAL CON FIBRA
DE CARBONO

5
5/11/2016

REFORZAMIENTO VERTICAL
CON EPOWRAP 2410,
FIBRA DE VIDRIO
UNIDIRECCIONAL

PUENTE BASCUN

LA SUPERFICIE ES
PREPARADA CON
MORTERO EPOXICO DE
RECUPERACION DE
SUPERFICIE, YA QUE
LA SUPERFICIE DEBE
SER UNIFORME SIN
IRREGULARIDADES,
PARA UNA CORRECTA
ADHERENCIA Y
TRANSMISION DE
ESFUERZO

6
5/11/2016

OBSERVATORIO
ASTRONOMICO DE QUITO
REFORZAMIENTO
ESTRUCTURAL MEDIANTE
FIBRA DE VIDRIO UNIDIRECCIONAL
Y POLIMERO EPOXICO

RECUPERACION TERMINADA OBSERVATORIO ASTRONOMICO

PUENTE LUIS A MARTINEZ

7
5/11/2016

PUENTE LUIS A MARTINEZ AMBATO

EDIFICIO
EX FILANBANCO

LA LICUADORA

ENCAMISADO
EPOWRAP SETMIX

PISO FISURADO DISCO DE ENSAYO FALLA DEL HORMIGON


REFORZAMIENTO
EPOWRAP SETMIX

FIBRA DE VIDRIO
ESTRUCTURAL
UNIDIRECCIONAL

8
5/11/2016

ENSAYO AL ARRANQUE DEL SISTEMA EPOWRAP


ENSAYO
RESISTENCIA A
TRACCION
CARBOWRAP 600

Optimum fiber placement: the pole vault


ENSAYO DE
BOMBA EN
COMPARTIMENTO
EQUIPAJE

REFUERZO DE
FIBRA DE VIDRIO
ANTIBOMBA EN
Optimum laminate has some fibers CONTENEDORES
on all axis. The result is a part that EQUIPAJE
has the following properties:
Light weight
Strong
durable

You might also like