GROUP
DENSITY & SPECIFIC GRAVITY METER (21 CFR Compliance )
as Per USP <841) Method II
Have all the features of Density Meter mentioned above and also have the following
NOTE: We have very High precision Density Meter Model DSA 5000M by which you can
also measure Sound Velocity apart from Density, Specific Gravity, Viscosity and
concentration of Binary and also Ternary samples.
We have simple Handheld Density Meter (DMA 35) without temperature control and
Portable battery operated( DMA 500) with Temperature control between 15 to 40 Deg.C
POLARIMETER (For OR and SOR Measurements with 21CFR compliance)
as per USP <781 > Optical Rotation Method
Measuring Scales: Optical Rotation, Optical Rotation (cell length corrected), Specific
Rotation,Specific Rotation (cell length corrected) , % concentration (g/100 mL, g/L,
g/100 cm3, kg/m3), International Sugar Scale (not temperature-compensated),
mathematic functions and user-definable scales
Tool Master Module : Unique Wireless Tool Master for direct sample cell data
transfer to instrument (viz. sr. no., length, volume, material of construction,
thermal expansion coefficient apart from the real time sample temperature)
offering complete traceability of data and also eliminates the human error during
sample cell selection.
Sample Cell: Our unique Wireless Sample cell does not have any cable wire
attached with it. It is wireless cell with a chip consisting of IR Sensor in it at the
bottom of it for data transfer from Sample cell to unit. It is very much easy to
take out the sample cell for cleaning and replace it back after cleaning. No
damage occurs to the Sample cell.
NOTE: We also have a simple , compact Polarimeter Model MCP 100/150 with
Temperature control at 20 and 25 / 15 to 35and having only single wave length of
589 nm and it cannot be upgradable with any other wave length. These instrument are
21CFR compliance .
REFRACTOMETER (For Refractive Index & Brix with 21CFR compliance)
as per USP <781 > Refractive Index Method
Measuring Range 1.26 to 1.72 nD
Accuracy 0.0001 nD Resolution 0.00001 nD
Temperature control by Inbuilt Peltier thermostat
Temperature range from 0 to 85 Deg.C
Compliance with 21 CFR Part 11 with multiple users management, unique password
protection, audit trail, electronic signature, etc. for safety of electronic data.
Wide range of communication options (USBs, RS232, Ethernet VGA, CAN)
Report Template in PDF Format
NOTE: We also have a simple Refractometer Model Abbemat 200 with Temperature
control at 15 and 60 Deg.C without 21CFR compliance.
Microwave assisted focused monomode organic synthesis system to handle the synthetic
reactions involving routine organic, organometallic,Nano materials synthesis,
fluorination, caustic solutions, catalysts using palladium, nonpolar solvents like toluene,
hexane etc.
NOTE: We also High End Microwave reactor Model MULTIWAVE PRO with 21 CFR
Compliance ( as per USP 232 & 233> method for DIGESTION and also for Synthesis.
Also have compact and low cost effective Synthesis reactor model MONOWAVE 50
for Synthesis application.