Features Advantages
The EagleBurgmann Thermosiphon systems of Operating limits up to 50 bar / 200C: suitable
the TS6000 range meet all the requirements to for a wide range of demanding operating
supply mechanical seals in accordance with the conditions
API 682 guidelines. The vessels are equipped Robust design with weld-pad type sight-glass
with all essential connections for fitting for optimum visual level monitoring
additional components. The range is available in Modular system: combination with a wide
two standard vessel sizes (shown: TS6000) with range of system components possible
dished heads; a version which can be A version which can be dismantled is also
dismantled is also available as an option. The available as an option: for optimum and
modular system allows the TS6000 vessels to simple cleaning of the vessel interior
be combined with a wide range of system
components such as, level switch/transmitter,
pressure switch/transmitter, base frame, etc.
Thermosiphon system
(API Plan 52)
Item Description
1 Level switch
2 Manometer
3 Manifold
4 Pressure switch
5 Shut-off valve
6 Orifice
Bottom
N6 Drain
N7 Cooling water IN
N8 Cooling water OUT
Cover
N9 Connection to flare
EagleBurgmann KE A/S Tel: +45 75 36 18 11 All technical specifications are based on extensive tests and our many years of experience. The
Park All 34 Fax: +45 75 36 15 32 diversity of possible applications means, however, that they can serve only as guide values. We
6600 Vejen info@dk.eagleburgmann.com must be notified of the exact conditions of application before we can provide any guarantee for a
Denmark www.eagleburgmann-ej.com specific case. Subject to change.
TS6000 (2)
Recommended applications Standards and approvals
Refining technology PED 97/23 EC
Oil and gas industry ASME VIII, Div. 1
Chemical industry
Petrochemical industry
Functional description
The TS system performs all the basic functions of a buffer/barrier system for the operation of double
seals:
to pressurize the buffer chamber
leakage compensation
buffer/barrier fluid is circulated by thermosiphon effect or forced circulation system
to cool the seal
to selectively absorb product leakage and prevent dry running (tandem arrangement)
Use compressed air or nitrogen for pressurization; pressurization is monitored by a pressure switch.
The incorporated level switch issues a signal whenever the level of buffer/barrier fluid is too low.
EagleBurgmann KE A/S Tel: +45 75 36 18 11 All technical specifications are based on extensive tests and our many years of experience. The
Park All 34 Fax: +45 75 36 15 32 diversity of possible applications means, however, that they can serve only as guide values. We
6600 Vejen info@dk.eagleburgmann.com must be notified of the exact conditions of application before we can provide any guarantee for a
Denmark www.eagleburgmann-ej.com specific case. Subject to change.
TS6000 (3)
Product variants
1) Design data, permissible working values depend on the actual conditions of service.
2) Guidelines with buffer/barrier fluid water 60 C cooling water 20 C.
3) Guidelines with buffer/barrier fluid water 60 C ambient temperature 20 C (valid for thermosiphon systems without cooling water with natural
circulation resp. forced circulation).
TSA6
Barrier/buffer system according to API 682 4th edition.
CLICK HERE
EagleBurgmann KE A/S Tel: +45 75 36 18 11 All technical specifications are based on extensive tests and our many years of experience. The
Park All 34 Fax: +45 75 36 15 32 diversity of possible applications means, however, that they can serve only as guide values. We
6600 Vejen info@dk.eagleburgmann.com must be notified of the exact conditions of application before we can provide any guarantee for a
Denmark www.eagleburgmann-ej.com specific case. Subject to change.
TS6000 (4)
TSB6
Barrier/buffer system according to API 682 4th edition.
CLICK HERE
EagleBurgmann KE A/S Tel: +45 75 36 18 11 All technical specifications are based on extensive tests and our many years of experience. The
Park All 34 Fax: +45 75 36 15 32 diversity of possible applications means, however, that they can serve only as guide values. We
6600 Vejen info@dk.eagleburgmann.com must be notified of the exact conditions of application before we can provide any guarantee for a
Denmark www.eagleburgmann-ej.com specific case. Subject to change.