HYDRODRAIN

1. Product Name

Eliminates the bulk and weight of one or both sides.
Hydrodrain conventional aggregate type drainage Hydrodrain 400, 420, 700, and 990
media consists of an impermeable polypropylene
2. Product Description Materials are resistant to all known sheet, containing 12.5% post-industrial
Basic Use naturally occurring earth salts and recycled content formed under heat and
Hydrodrain is a composite drainage minerals pressure to produce a high-flow dimple-
layer consisting of a three-dimensional The white filter fabric (Hydrodrain 300, type drainage core with woven or non-
drainage core and a filter fabric. The 302 and 1000) reduces the potential woven filter fabric bonded to one side.
filter fabric is bonded to the core, heat build up underneath the drainage
preventing intrusion of the fabric into the layer decreasing the potential for Types
flow channels. The fabric extends equally STYROFOAM insulation deformation. Hydrodrain 300 is a geonet-type core
(approx. 2") along both long sides, with non-woven white filter fabric bonded
beyond the core for overlap adjoining Limitations to one side. The filter fabric retains
rolls. Hydrodrain is ideal anywhere a Hydrodrain is not to be used as the soil or sand particles as well as freshly
subsurface drainage course is required. sole protection for Hydrotech roofing and placed concrete allowing filtered water
Typical applications include foundation waterprpofing materials to pass through to the drainage core.
walls, trench drains, planters, plaza decks Hydrodrain is not to be set directly Hydrodrain 300 is primarily installed
and roof assemblies. into or over Hydrotechs Monolithic horizontally for areas subjected to heavy
Membrane 6125 without the installation loading or vehicular traffic but may also
Advantages of a protection course be installed vertically. Hydroflex 30 or
Reduces hydrostatic pressure on below- another approved protecting layer must
grade structures Composition and Materials be installed over Hydrotechs roofing and
Enhances conventional waterproofing Hydrodrain 300, 302 and 1000 waterproofing membranes if Hydrodrain
systems by transmitting water into a consist of a heavy duty, high density 300 is installed above.
collection system before it reaches the wall polyethylene geonet-type drainage core,
substrate containing 10% post-industrial recycled Hydrodrain 302 is identical to
Decreases the risk of potential freeze-thaw content, with a non-woven white filter Hydrodrain 300 with the addition of a
damage to a concrete wearing surface fabric heat fused to the core ridges on second layer of the non-woven white filter
PH Y SI CAL PROPE RTIE S (Ta b le 1 )

Geonet Style Dimple Style


PROPERTY TEST METHOD UNITS 300 302 1000 400 420 700 990
Thickness ASTM D1777 inches 0.25 0.25 0.25 0.4 0.4 0.4 0.4
(mm) (6.35) (6.35) (6.35) (10.16) (10.16) (10.16) (10.16)

Compressive Strength ASTM D1621 psf 40,000 40,000 40,000 15,000 15,000 21,000 30,000
(kN/m2) (1,915) (1,915) (1,915) (718) (718) (1,005) (1,436)

Core Flow ASTM D4716 gal/min/ft 8.5 8.5 8.5 21 21 23 24


@3600 psf (l/min/m) (106) (106) (106) (261) (261) (286) (298)
Hydraulic gradient = 1
(per unit width)
Fabric Flow ASTM D4491 gal/min/ft2 150 150 150 140 140 60 60
(l/min/m2) (6,112) (6,112) (6,112) (5,704) (5,704) (2,460) (2,460)

Fabric Grab ASTM D4632 lb 95 95 95 100 100 MD 370 (1.65) MD 370 (1.65)
Tensile Strength (kN) (.423) (.423) (.423) (0.45) (0.45) CD 250 (1.11) CD 250 (1.11)

Fabric AOS (EOS) ASTM D4751 U.S. Sieve 50 50 50 70 70 40 40


(mm) (0.3) (0.3) (0.3) (0.212) (0.212) (0.42) (0.42)

Fabric Puncture Strength ASTM D4833* lb 55* 55* 55* 250 250 850 850
ASTM D6241 (kN) (0.245) (0.245) (0.245) (1.113) (1.113) (3.78) (3.78)

Fabric UV Resistance ASTM D4355 % strength 70 70 70 70 70 - -


@ 500 hours retained
Roll Dimensions 4' x 75' 4' x 75' 4' x 50' 4' x 50' 4' x 50' 4' x 50' 4' x 50'

Roll Weight 70 lbs 80 lbs 55 lbs 39 lbs 40.5 lbs 50 lbs 52 lbs
300 302 1000

400 420 700


fabric to the back side. The bottom layer be installed over Hydrotechs roofing and
of filter fabric can assist in dispersing waterproofing membranes if Hydrodrain
water in flat applications and can be 400 is installed above. Hydrodrain
used in situations where drainage from 400 may not be installed directly
both sides is required. Hydroflex 30 or over STYROFOAM insulation.
another approved protecting layer must Hydrodrain 420 is identical to
be installed over Hydrotechs roofing and Hydrodrain 400 with the addition of a
waterproofing membranes if Hydrodrain polymeric laminate film to the back side.
302 is installed above. The polymeric film provides additional
protection to the roofing/waterproofing
Hydrodrain 1000 is identical to membrane allowing Hydrodrain 420 to
Hydrodrain 300 with the addition of a be installed directly over cured LM6090
layer of heavy duty fabric to the back and MM 7800, or VM75 membranes.
side. The heavy duty fabric provides Hydroflex 10 or 30 protection is
additional protection and cushion against still required when Hydrodrain 420
the roofing/waterproofing membrane. is to be installed over MM 6125. 990
Hydrodrain 1000 is primarily installed Hydrodrain 420 is primarily installed
horizontally in roofing applications where vertically but may also be installed be installed horizontally. Hydroflex 30 or
Hydroflex 10 separation/protection sheet horizontally. Hydrodrain 420 may another approved protecting layer must
is installed over the MM 6125 membrane not be installed directly over be installed over Hydrotechs roofing and
but may also be installed vertically STYROFOAM insulation. waterproofing membranes if Hydrodrain
directly over cured LM6090 and MM 700 is installed above. Hydrodrain
7800, or VM75 membranes. Hydrodrain 700 is virtually identical to 700 may not be installed directly
Hydrodrain 400 except that a woven over STYROFOAM insulation.
Hydrodrain 400 is a dimple-type core filter fabric is bonded to one side. The
with non-woven filter fabric bonded to filter fabric retains soil or sand particles Hydrodrain 990 is identical to
one side. The filter fabric retains soil or as well as freshly placed concrete Hydrodrain 700 except that the
sand particles as well as freshly placed allowing filtered water to pass through dimpled core consists of a heavier duty
concrete allowing filtered water to pass the to the drainage core and provides polypropylene sheet that provides a
through to the drainage core. Hydrodrain additional compressive strength to the higher compressive strength. The woven
400 is primarily installed vertically for overall drainage composite. Hydrodrain filter fabric bonded to one side retains
moderate duty applications but may also 700 is primarily installed vertically for soil or sand particles as well as freshly
be installed horizontally. Hydroflex 30 or moderate duty applications but may also placed concrete allowing filtered water
another approved protecting layer must to pass through the to the drainage core.
Hydrodrain 990 is primarily installed must be taken to reduce the Position the Hydrodrain down the wall,
horizontally where high compressive chances of heat build up due to maintaining a straight and vertical
strength and flow are desired but may sun and ambient temperatures. installation.
also be installed vertically. Hydroflex Damage to STYROFOAM can
30 or another approved protecting occur in ambient temperatures as At the drain tile or linear collection
layer must be installed over Hydrotechs low as 85 - 90 degrees F. Refer assembly (if installed), peel back the filter
roofing and waterproofing membranes to Technical Bulletin #3 for more fabric from the drain core and wrap the
if Hydrodrain 990 is installed information. drain tile with the fabric. The drain core
above. Hydrodrain 990 may can be trimmed as necessary. If no drain
not be installed directly over Notes: When necessary, additional tile is installed, wrap the bottom edge of
STYROFOAM insulation. filter fabric may be cut and used the core with the filter fabric overlap or
to simply cover over or wrap any additional filter fabric.
Size/Packaging exposed or open drainage core
All Hydrodrain product is shipped in rolls edges. This may be especially helpful Install adjacent rolls of Hydrodrain in
packaged in polyethylene bags. Refer to in instances where the memory the same manner described above.
Table 1 for roll dimensions and weights. inherent in the geonet-type cores If necessary, adhere the Hydrodrain
results in wavy edges. along vertical joints making sure that the
3. Technical Data drain cores abut directly and that the
Refer to Table 1 for typical physical Filter fabric overlaps may be secured filter fabric overlap completely covers
properties of Hydrodrain. over the adjacent roll of Hydrodrain the joints. Use additional filter fabric,
as necessary with duct tape or a adhered over the joints, if necessary to
4. Installation compatible adhesive. ensure complete coverage of the joints.
Horizontal Installations (all types)
The waterproofing should have been Hydrodrain may be spot attached to Total Height With Multiple Lifts
installed, properly protected, and tested the surface of protection course with Installation of Hydrodrain in multiple
for leaks. The area to be covered with double-sided tape or a compatible lifts is essentially identical to the single
Hydrodrain should be swept clean of all adhesive. Spot attachment over lift installation described above except
loose debris. STYROFOAM insulation may be that the filter fabric lap is formed and
accomplished with double-sided tape, adhered to the wall (or waterproofing)
Start unrolling the first roll of Hydrodrain a compatible adhesive or staples at surface only at the very top of the
along an edge of the area to be covered least 1 inch shorter than the thickness installation only with the last lift of
with the filter fabric facing up. The fabric of the foam. Hydrodrain.
overlap along the work area perimeter
should be folded under the core all along Vertical Installations The top of each preceding lift of
the perimeter edge. (Fig. 1) If installing (Hydrodrain 400, 420, 700, 990, 1000) Hydrodrain must be installed so that the
Hydrodrain along a sloped surface, The waterproofing should have drain cores of adjacent lifts directly abut
installation should begin at the bottom been installed, properly protected (if each other. Any filter fabric overlaps
of the slope, extending upslope so that necessary), and fully cured (if required). should be shingled from the upper lift
a fabric overlap from the subsequent down over the lower lift of Hydrodrain.
The height of the wall or lift to be covered (Fig. 5)
rolls upslope will shingle down over the
should be measured, adding sufficient
previous roll.
material if necessary for overlapping the Placement of backfill should occur as
Subsequent rolls of Hydrodrain should be drain tile or linear collection assembly at soon as possible after Hydrodrain
installed so that the drain cores directly the base of the wall. Alternatively, extra/ installation.
abut each other. This may necessitate additional filter fabric may be used to
peeling the fabric back off of the core on overlap the first lift of Hydrodrain at the 5. Availability and Cost
one roll of Hydrodrain to allow the fabric base of the wall and warp the drain tile. Contact you local American Hydrotech,
overlap from the adjacent roll to lay flat Inc. representative of Hydrotech directly.
Hydrodrain should be unrolled and cut to
across the top of the adjacent core. The
length if necessary. 6. Guarantees
peeled back fabric may then be laid flat
across the top of the adjacent roll. (Fig. Contact American Hydrotech, Inc. for
Total Height With One Lift specific warranty information.
2) All joints and core edges must be When the total height of the wall will be
covered/wrapped with filter fabric. covered with a single lift of Hydrodrain, 7. Maintenance
start by peeling the filter fabric back from None required.
At roll ends, this may be accomplished
the drain care at the top of the roll to
by peeling the filter fabric back from the
expose 4 inches of the core. 8. Technical Services
core of the to-be-placed roll, exposing
Note: the drain core should remain 6 Technical support is provided by a
at least 4 inches of drainage core. The
12 inches below the final surface of trained network of sales representatives
core is then cut off and the end of the
the backfill and Hydrotechs Technical Services
roll positioned so that the exposed core
Department.
abuts the previous core. The excess fabric Glue the fabric overlap at the top of the
is then lapped over the previous roll of wall using double-stick tape, duct tape,
Hydrodrain. (Fig. 3) a compatible adhesive, or stick pins
depending on the surface. (Fig. 4) Note:
Installed Hydrodrain should not
nails or staples are not appropriate if
be left exposed for extended
they will penetrate the waterproofing.
periods (> 30 days). If installed
over STYROFOAM insulation steps
Fig. 1

Fig. 2

Fig. 3

GRADE

6"

Fig. 4 Fig. 5

American Hydrotech, Inc. Hydrotech Membrane Corporation


303 East Ohio Street, Chicago, Illinois 60611 10,951 Parkway, Ville DAnjou, Quebec H1J 1S1
800.877.6125; 312.337.4998 800.361.8924; 514.353.6000
312.661.0731 (fax) 514.354.6649 (fax)
www.hydrotechusa.com www.hydrotechmembrane.ca

The information given is based on data and knowledge considered to be true and correct and is offered for the users consideration, investigation and verification.
2016 AMERICAN HYDROTECH INC. The information is subject to change without notice. The determination of suitability and fitness of the products and the application described herein for a particular
purpose is the sole responsibility of the user. Please read all statements, recommendations and suggestions in conjunction with the conditions of sale which apply to
all goods sold by American Hydrotech, Inc. for the United States and abroad, or Hydrotech Membrane Corporation for Canada, including the express disclaimer
2016-TDS-3-HDRAIN-JS by each company of the implied warranties of merchantability or fitness for a particular purpose. Nothing stated herein is intended to infringe on any patent or
copyright.

You might also like