You are on page 1of 6

TUGAS PENILAIAN RISIKO

Dahliana Alami 141424008


Nama
Mira Auliya Tsaqila 141424021
Kelas 3-TKPB

Operating Unit : Gas-Liquid Separation System


Equipment : Separator
Equipment Number :
Description : D= 20
Level of Analysis : Lv 2 (Semi-Quantitative)

Part A RELEASE RATE CALCULATION


Estimation of release rates for different hole sizes and release types and dura
Step 1 CALCULATE RELEASE RATE
1 MATERIAL : C9-C12
2 Inventory value : 50000
2a Inventory category: C
3 Detection Rating : B
4 Isolation Rating : B
5 Leak Duration 1/4 inch 1 Inch
(minute) 40.00 30.00
6 Operating Pressure 800.00
(psia)
7 Fluid phase Liquid

LIQUID RELEASE UNIT


Cd 0.61
45.823 Lb/ft3
Dp
gc 32.2 lbm-ft/lbf.s2
D
A
15 Liquid Release Rate =
16 Time required to deinventory
Flow Rate 3 min
17 Release type

DETERMINATION OF PHASE AFTER RELEASE


18 TNBP 364 F
19 Phase of the fluid liquid
20 Release type
21 Release duration
DETERMINATION OF INSTANTANEOUS RELEAS
22 Instantaneous release mass 50000

Part B LIKELIHOOD ANA


Likelihood Analysis is the product of several factors that can indicate likelihoo
Step I TECHNICAL MODULES SUBFACTOR (See Section 8.3.1)
Screen to identify damage mechanisms. Use appropriate damage mechanism
determine individual factors.
If no damage mechanisms are identified, then enter -2 as technical module s
1 Identified damage mechanisms
1a. Thinning/Corrosion (Y/N)
1b. HTHA (Y/N)
1c. SCC (Y/N)

2 Age of equipment in current service


2A. Estimated/measured corrosion rate
2B. Nelson Curve Temperature
2C. SCC Crack Size or Susceptibility
3 Calculate left column of Technical Module table
4 Determine inspection equivalents (H, U, F, P, I)
4A. Number of Inspections
5 Technical module subfactor from table
6 Correction for overdesign
7 Correction for highly reliable damage rate data
8 Corrected technical module subfactor
9 Combined technical module subfactor
10 Likelihood category from Table B-6 of Appendix VIII

Part C1 FLAMMABLE CONSEQUENCE


Estimation of the flammable consequences area for equipment an
REPRESENTATIVE MATERIAL
1 REPRESENTATIVE MATERIAL : C9-C12
RELEASE TYPE
2 Release type CL
RELEASE RATE OR MASS
3 Liquid Release Rate = 0.270016493
DETECTION RATING
4 DETECTION RATING B
ISOLATION RATING
5 ISOLATION RATING B
ADJUSTMENTS FOR FLAMMABLE EVENT MITIGATION (x)
6 Reduce release rate or mass by 15% 0.229514019
EQUIPMENT DAMAGE AREA
7 A (ft2) fromTable 7.10 and 7.11 96.59296887
POTENTIAL FATALITIES AREAS
8 A (ft2) fromTable 7.10 and 7.11 253.2873429
CONSEQUENCE REDUCTION
9 Equipment Damage Area
Fire water deluge system and monitors 77.2743751
10 Area of Fatalities
Fire water deluge system and monitors 202.6298743

Part C2 TOXIC CONSEQUENCE CA


Estimation of the toxic consequence are
1 MATERIAL : C9-C12
HOLE SIZES >
2 Release type
3 Liquid Release Rate =
4 Release duration
5
6 Instantaneous release mass
7 Consequence area for release mass
8 Toxic consequence area >

Part D RISK CALCULATI


HOLE SIZES >
1 Generic failure frequency
2 Sum of Failure Frequencies
3 Fraction contribution
4 Area of Fatalities
5
6 Toxic consequence area >
7
8 Flammable Consequence area value
9 Toxic Consequence area value
10 Consequence Category
11 Likelihood Category
12 Risk Category
E RATE CALCULATION
s and release types and durations for each of the hole sizes.

4 inch Rupture
20.00 5.00

E UNIT

0.25 1.00 4.00 16.00 Inch


0.05 0.79 12.56 200.96 Inch2
0.270016 4.320264 69.12422 1105.988 lb/sec
3086.23 192.89 12.06 0.75 min
48.60297 777.6475 12442.36 199077.8 lb
Cont Cont Inst Inst

E AFTER RELEASE
184.4444 C

CL CL IL IL
11429.79 44.64761 0.174405 0.000681 Min
INSTANTANEOUS RELEASE MASS
lbs

LIKELIHOOD ANALYSIS
ors that can indicate likelihood of equipment failure.
tion 8.3.1)
ropriate damage mechanism technical module (see Appendix VIII) to

nter -2 as technical module subfactor (Line 11).

1a 1b 1c

DATA KURANG LENGKAP

AMMABLE CONSEQUENCE CALCULATIONS


ences area for equipment and personnel due to an ignited release of hydrocarbon

CL IL IL

4.320264 69.12422 1105.988 lb/sec

3.672224 58.75559 940.0894 lb/sec

1345.425 3371.525 18295.3 ft2


3246.414 12860.5 73765.54 ft2

1076.34 2697.22 14636.24 ft2

2597.131 10288.4 59012.43 ft2

TOXIC CONSEQUENCE CALCULATIONS


of the toxic consequence area for a release of HF or H2S

1/4 inch 1 Inch 4 inch Rupture


CL CL IL IL
0.270016 4.320264 69.12422 1105.988 lb/sec
11429.79 44.64761 0.174405 0.000681 Min
3300 60000 - - ft2
- - 50000 50000 lbs
- - 15000000 15000000 ft2
3300 60000 15000000 15000000 ft2

RISK CALCULATIONS
1/4 inch 1 Inch 4 inch Rupture
0.00004 0.0001 0.00001 0.000006
0.000156 /year
0.25641 0.641026 0.064103 0.038462 ft2
202.6299 2597.131 10288.4 59012.43 ft2
51.95638 1664.828 659.5129 2269.709 ft2
3300 60000 15000000 15000000 ft2
846.1538 38461.54 961538.5 576923.1 ft2
4646.0057783808 ft2
1577769.23076923 ft2
E
DATA KURANG LENGKAP