You are on page 1of 2

NroEdW

uct!
P
Battery
Range Summary
EnerSys PowerSafe OGi monoblocs
are classic vented lead-acid batteries
ideal for applications with high safety
requirements and with high rate
Features & Benefits
discharges such as UPS systems.
Proven, reliable flooded lead-acid Rod plate
battery technology PowerSafe OGis technology is also
Excellent for fast discharge applications perfectly suited for longer duration
Industry-standard size containers discharges (hours) in the telecom,
Large Ampere-hour range: 55Ah to 1000Ah utilities and renewable energy industries.
(C10/1.80Vpc/20C)
PowerSafe OGis special Rod plate design, familiar to
Choice of 2, 6 and 12 volt blocs
EnerSys for over 35 years, offers a high energy density
Long operational life for great footprint savings, a long service life and good
Topping-up intervals: circa 3 years in standby cyclic capabilities in industry-standard container sizes.
operation at 20C Furthermore the low antimony lead alloy reduces water
topping-up intervals and subsequently maintenance costs.
Comprehensive operating temperature range
All monoblocs available filled and charged The vent design and the grid alloy reduce maintenance
Compliant with DIN 40737-3 intervals and costs while transparent containers make
visual inspection easier. The high integrity terminal design
(dimensions) standard
maximises the operational safety and allows for fast and
easy voltage and ohmic measurement readings.

Visit us at www.enersys-emea.com
Construction General Specifications

Positive electrode - Rod plate with low Nominal Capacity (Ah) Nominal Dimensions (mm)

antimony lead alloy. Proven design and Voltage C10 @ 20C Typical Weight
(V) to 1.80Vpc Length Width Height (Kg)
radial grid structure ensure superior
long-term behaviour 12 OGi 60 12 55 272 205 385 30.0
Negative electrode - pasted flat plates 12 OGi 80 12 83 272 205 385 45.0
provide perfect balance with the positive 12 OGi 110 12 111 272 205 385 55.0
plates to give maximum performance
Separation Special microporous 12 OGi 140 12 139 380 205 385 69.0
separator, combined with glass fibre mat 12 OGi 170 12 166 380 205 385 84.0
Container Moulded from durable, high 6 OGi 200 6 194 272 205 385 49.0
impact resistant, clear SAN (styrene
6 OGi 230 6 222 272 205 385 56.0
acrylonitrile) to allow electrolyte level and
bloc condition to be monitored visually 6 OGi 250 6 250 380 205 385 63.0
Lid material in strong, opaque ABS 6 OGi 280 6 278 380 205 385 68.0
polymer. Sealed to container to ensure no
6 OGi 300 6 305 380 205 385 76.0
electrolyte leakage
Electrolyte - Dilute sulphuric acid with a 6 OGi 330 6 333 380 205 385 83.0
specific gravity of 1.240 (maximum level) 2 OGi 670 2 667 272 205 385 58.0
for long lasting and reliable performance 2 OGi 830 2 834 380 205 385 69.0
Terminal design - Leak-proof, M10
female, safety pole with brass insert 2 OGi 1000 2 1000 380 205 385 83.0
Vent plugs Proven, high integrity
design. Equipped with flame arrestors for
additional safety
Connectors Flexible inter-bloc cable Outline Drawings
connectors. Cable end shrouds allow for
voltage measurement

15.16
(385)
14.37

15.16
(365)

(385)
14.37
13.74

(365)
(349)

13.74
13.07

(349)
(332)

13.07
(332)
Installation & Operation

Float charge voltage: 2.23Vpc at 20C (272) (205)


8.07
(380) (205)
10.70
Permissible operating temperature range:
14.96 8.07

-10C to +45C 12 OGi 60 12 OGi 140


Small floor area required for installation 12 OGi 80 12 OGi 170
due to high energy density 12 OGi 110
2.13
(54)
2.13
(54)

Large selection of stands, including


(310)
(220) 12.20
8.66

seismic stands, available upon request

Standards
15.16
(385)
14.37
(365)
13.74

15.16
(349)

(385)
14.37
13.07

(365)
(332)

13.74
(349)

13.07
(332)
Designed to be compliant with the
requirements of the international IEC (272) (205)
60896-11 standard 10.70 8.07 (380)
14.96
(205)
8.07

Designed to be compliant with


2.13
(54)

2.13
(54)

DIN 40737-3 standard (relates to 6 OGi 200 6 OGi 250


dimensions specifically) 6 OGi 230 6 OGi 280
Products should be installed in accordance 6 OGi 300
2.13
(54)

2.13
(54)

6 OGi 330
(176)
(248)

with EN 50272-2, IEC 62485-2 and


6.93
9.76

local regulations
14.37

15.16
(365)

(385)
14.37
(365)

15.16
(385)

13.07
(332)
13.07
(332)

(272) (205)
10.70
(380) (205)
8.07
14.96 8.07
2.13
(54)

2.13
(54)

2 OGi 670 2 OGi 830


2 OGi 1000
2.13
(54)

2.13
(54)

(176) (248)
6.93 9.76

EnerSys World Headquarters EnerSys EMEA EnerSys Asia


2366 Bernville Road, Reading, EH Europe GmbH, 152 Beach Road,
PA 19605, USA Lwenstrasse 32, Gateway East Building #11-03,
Tel: +1-610-208-1991 / 8001 Zurich, Singapore 189721
+1-800-538-3627 Switzerland Tel:+65 6508 1780

2015 EnerSys. All rights reserved. Trademarks and logos are the property of EnerSys and its affiliates. Subject to revisions without prior notice. E.&O.E.
EN-PS-OGiB-RS-002- August 2015