You are on page 1of 10

MASTER PLUMBER Licensure Examination

Final Pre-Board

PLUMBING CODE Rating _______

1. The sanitary drainage system for public health reason, must discharge into
a. waterway b. public storm drainage c. public sewer d. ground

2. Sleeves protecting pipe that pass through foundation wall should be this size
a. two size larger than the pipe c. three sizes larger than the pipe
b. same size as the pipe d. one size larger

3. The pipe material not suitable for use in in-house plumbing for a potable water
system is
a. brass pipe b. concrete pipe c. galvanized iron pipe d.
plastic pipe

4. The pipe materials not suitable for used in the service of hot water system is
a. copper pipe b. black iron pipe c. galvanized iron pipe d.
brass pipe

5. What is the minimum capacity of water tank needed for a complete water closet
flushing
a. 3 gallon b. 4 gallon c. 5 gallon d. 7 gallon

6. The water retained in a fixture trap after flushing is called


a. trap seal b. mechanical seal c. dry seal d. back flow
preventer

7. It is a public space, public park or thoroughfare less than three (3) meters but not
less than two meters in width which has been dedicated or deeded to the public
for use.
a. court b. alley c. car park
d. yard

8. Identify a connection in which a ball is held in or cup like shell that allow
movement in any direction.
a. universal joint b. ball joint c. screwed joint d. bell &
spigot joint

9. A vent pipe connecting from a branch of a drainage system to a vent stack


a. looped vent b. branch vent c. yoke vent d. dry vent
10. A fitting into which the end of a pipe is screwed for the purpose of closing the end
of the pipe is called:
a. blank flange b. blind flange c. cap d. plug

11. A stop valve place in a service pipe near its connection with the water main is
called
a. service cock b. corporation cock c. stop cock d. gate valve

12. Identify the extended portion of a pipe that is closed at one end to which no
connection are made on the extended portion; thus permitting the stagnantation of
water or air therein,
a. clean out b. dead end c. faucet d. lateral line

13. A valve in which the flow of water is cut-off by means of a circular disc that fits
against the valve end. The place of movement of the disc is parallel to the normal
direction of flow of water which is turned through a tortuous passage to direct the
flow to the face of the disc.
a. gate valve b. globe valve c. check valve d. foot valve

14. It is that part of a plumbing system extending from a point of about 1.20 m to 1.50
m from the inner face of the foundation wall of a building to any point of
discharge.
a. house drain b. house sewer c. lateral d. storm drain

15. A receptacle designed and constructed to separate and prevent the passage of oil,
grease, lard or other materials into the drainage system
a. interceptor b. grease trap c. manhole d. catch basin

16. An outhouse or structure used for deposition of excrement in rural area


a. septic vault b. privy c. leaching cesspool d. latrine

17. The vertical distance between the dip and the crown weir of a trap is called
a. seal b. goose neck c. fixture drain d. leader

18. A pit or receptacle at its lowest point of a basement floor to which the liquid waste
are drained
a. sub drain b. sump pit c. underground tank d. house drain

19. A vertical pipe usually used for the storage of water frequently under pressure
a. riser pipe b. stand pipe c. pressure pipe d. service pipe

20. An arrangement of venting so installed about one vent pipe will serve two traps
a. unit vent b. side vent c. circuit vent d. back vent

21. A vent in that portion of a vent pipe system through which liquid waste flow
a. wet vent b. individual vent c. stack vent d. yoke vent
22. It is that portion of the rainfall or other precipitation which runs off on the ground
surface after a storm and for such short flood following a typhoon
a. splash flood b. surface water c. storm water d.ground water

23. Revocation of permit cancellation and rejection of new application for plumbing
permit are imposed for the following ground.
a. improper conduct b. bad faith c. violation of the code d. all of the above

24. When there is changes in the direction of flow in soil or waste line from
horizontal to vertical , the bend to use is;
a. short quarter vent b. single sanitary tee c. tee d. all of these

25. The prohibited fittings such as double hub or double tee branch are not allowed
in:
a. vertical soil pipe b. horizontal soil pipe c. vent pipe d. none of the above

26. Joints and connections in pipes shall be made permanently:


a. gas tight b. water tight c. air tight d. all of these

27. Roof terminal of any stack or vent shall be extended above highest opening, at
any distance away any door, window or air shaft.
a. 3 meters b. 2 meters c. 1 meter d. 2 meters

28. The distance of vent pipe from a trap shall be not more than these length
a. 5 ft b. 4 ft c. 6 ft d. 3 ft

29. A portion of the pipe which is for a short distance is sufficiently enlarge to receive
the end of another pipe, it is called:
a. grove b. hub c. slit d. mouth

30. Any part of the piping system in a roughing-in installation other than the min,
riser or stack:
a. extension b. branch c. lateral d. reserve pipe

31. For offices, factories, school and colleges, one water closet, one floor drain and
one lavatory shall be required for every number of females:
a. every 20 females b. every 30 females c. every 10 females d. every 40
females

32. For offices, factories, school and colleges, one water closet, one floor drain and
one lavatory shall be required for every certain number of males:
a. every 40 males b. every 50 males c. every 60 males d. every 70
males
33. Back vent pipe line which connect directly with individual trap underneath the
fixture and extended to a branch or main at any point higher than fixtures, this is
sometime called:
a. local vent b. wet vent c. individual vent d. side vent

34. The battery of fixtures in any of two or more similar adjacent fixtures which
discharges to a common pipe called:
a. horizontal branch b. lateral pipe c. main soil stack d.main drainage pipe

35. Provision in the Code which spell that all pipe, cast iron, and steel pipe copper,
vitrified, concrete and asbestos pipe should conform to the approved Philippine
standard of ASTM standard specification.
a. Section 162 b. Section 163 c. Section 100 d. Section 165

36. It is specified in Section 169 of the NPC that all joints on vitrified pipe and
cement pipe shall be:
a. poured joint b. slip joint c. caulk joint d. wipe joint

37. When a basement drain inlet is subjected to backflow such drain shall be
equipped with a suitable valve
a. checked valve b. back water valve c. gate valve d. relief valve

38. The roof terminal of any stack or vent within 3m of any doors, window, air shaft
shall extend at least:
a. 0.30 mm b. 0.60 mm c. 0.90 mm d. 120 mm

39. The distance of vent from trap seal shall not be more than:
a. 1.20 m b. 0.60 m c. 1.50 m d. 1.00 m

40. When fixtures discharge to the branch soil pipe; with eight fixtures, such branch
shall be provided with a relief vent the diameter of soil pipe and installed later
on fixtures connection.
a. infront of first fixtures c. infront of third fixtures
b. infront of second fixtures d. infront of 4th fixtures

41. The size of house sewer, house drain and horizontal branches in plumbing
instillation is determined by the number of fixtures units and on the percentage
slope of pipe branch fixtures such as:
a. 2 % b. 3% c. 4% d. all of these

42. If a plumbing system is to be tested by air, an air pressure application is maintain


for 10 minute for each section at pressures:
a. 1 psi b. 2 psi c. 3 psi d. 3 psi

43. The longest branch vent pipe permitted in plumbing is not to exceed
a. 50 ft b. 25 ft c. 30 ft d. 40 ft
44. The National Plumbing Code is approved on this date:
a. January 25, 1959 b. June 18,1955 c. Feb. 28, 1958 d. June 18,
1956

45. The Law passed to regulate the trade of Master Plumber is known to be:
a. RA 544 b. RA 1364 c. RA 1378 d. RA 4565

46. The drainage system is designed, constructed and maintained so as to guard


against
a. obstruction b. clogging c. deposit of solid d. all of these

47. The prohibited traps for/in plumbing fixtures are the type:
a. Full S-trap c. trap with movable internal part
b. Bag type trap d. all of these

48. The cause of trap seal losses can be attributed to:


a. evaporation b. capillary attraction c. wind effect d. all of these

49. Rain water leaders when place inside the building shall be made of the materials
a. galvanized iron pipe b. Asbestos cement pipe c. Cast iron pipe d. PVC pipe

50. What section of the National Plumbing Code that allows reprocity in the practice
of the Plumbing Profession between the Philippines and other countries.
a. Section 9 b. Section 20 c. Section 21 d. Section 22

51. A pipe connecting upward from a soil or waste stack below the floor and below
horizontal connection to an adjacent vent stack at a point above the floor and
higher than highest spill level of fixtures for preventing pressure changes in the
stacks.
a. yoke vent b. relief vent c. wet vent d. stack vent

52. An open, unoccupied space, other than a court, unobstructed from the ground to
the sky, except where specifically provided in the Code.
a. yard b. air gap c. atmosphere d. outer space

53. A hose connection with two-gated outlets permitting two connections of the same
or smaller coupling diameter to be taken from a single supply line. Also, a pipe
fitting of three branches.
a. wye b. vent c. bend d. elbow

54. Any joint or seam obtained by the joining of metal parts in a plastic molten state.
a. welded b. soldered c. flared d. threaded

55. That portion of a vent pipe through where wastewater also flows through.
a. yoke vent b. relief vent c. wet vent d. stack vent
56. The pipe connection upward for the soil or waste stack to a vent stack for the
purpose of preventing pressure changes in the vent stack is:
a. back vent b. yoke vent c. side vent d. relief vent

57. A faucet opened or closed by the fall or rise of a ball floating in the surface of
water is called:
a. float valve b. bibb c. ball cock d. top faucet

58. A controlled outlet of a pipeline used to discharge water or detritus:


a. overflow b. blow-off c. faucet d. by-pass line

59. The part of a plumbing system other than the main riser or stack.
a. lateral b. vent c. branch d. downspout

60. A metallic sleeves, caulked or other wing joined to an opening in a pipe, into
which a plug is screwed that can be removed for the purpose of cleaning and
examining the interior of the pipe.
a. flashing b. ferrule c. clean out d. cap

61. A receptacle attached to a plumbing system other than a trap in which wastes may
be collected or retained for ultimate discharge into the plumbing system.
a. fixture b. catch basin c. roof drain d. bleeder

62. The level in a fixture at which water begin to overflow the top or rim of the
fixture is called:
a. grade line level b. flood level c. flow level d. crown level

63. In plumbing a secondary pipeline, in sewerage a common sewer to which no other


common sewer is tributary. It received sewage only from building sewer
a. lateral line b. interceptor line c. house drain d. house service line

64. It is water which is satisfactory for drinking, culinary and for domestic purpose
and meet the requirement of the health authority having jurisdiction.
a. distilled water b. palatable water c. potable water d. spring water

65. As provided by the NPC, plumbing installation shall be commenced starting from
the date of issuance by the plumbing authority to within the period of
a. 1 month b. 3 months c. 5 months d. 6 months

66. An additional surcharge imposed to upon any master plumber for every plumbing
installation, repair or alteration made without first securing plumbing permit
before commencing the same.
a. 10% surcharge b. 30% surcharge c. 50% surcharge d.100% surcharge
67. What vent pipe installation in the building which has no connection whatsoever,
with the plumbing fixtures?
a. bleeder pipe b. ventilating pipe c. side vent d.exhaust pipe

68. The code provide that joint of protruding pipe thru roof shall be made by the use
of such kind of metal
a. copper sheet b. lead sheet c. galvanized iron sheet d. all of these

69. Circuit and looped vent are permitted only to branch soil or waste pipe with
specific number fixtures like water closet, urinal, and other which will not exceed:
a. 6 fixtures b. 8 fixtures c. 5 fixtures d. 10 fixtures

70. Clean-out installation in a vertical waste or soil stack is placed at


a. at the foot of the vertical pipe c. above vertical pipe
b. below each branch d. above roof extension

71. The distance between the hot and cold water rise when hot water is installed
should be:
a. 150 mm b. 200 mm c. 100 mm d. 50 mm

72. The design, construction and maintenance of septic tank are essentionally the
responsibilities of:
a. Sanitary Engineer b. Civil Engineer c. Master Plumber d. DOH

73. The National Plumbing Code was approved by the President when?
a. June 18, 1959 b. January 28, 1959 c. June 18, 1955 d. June 28, 1955

74. Roof extension of soil and waste stack shall run full size and extend at this height
for purposes other than weather protection
a. 0.30 m b. 1.50 m c. 0.60 m d. 0.90 m

75. The waste pipe leading to the ejector or other appliances for raising sewage to the
street sewer and where water closet is installed should be provided with vent.
What is the size of this vent required?
a. 100 mm diameter b. 150 mm diameter c. 50 mm diameter d. 75 mm
diameter

76. What is the minimum fixture unit for each family dwelling on premises abutting
on sewer or with a private sewage disposal system?
a. one water closet and one lavatory c. one water closet and one
shower head
b. one water closet and one slop sink c. one water closet and one kitchen
sink
77. What is that part of a vent line which connects directly with an individual trap
underneath or behind the fixture and extends to the branch or main, soil or waste
pipe at any point higher than the fixture or fixture trap it serve?
a. continuous vent b. circuit vent c. main vent d. back vent

78. What is the maximum fixture units of a 4% slope, 4 inches house drain can drain?
a. 120 FU b. 150 FU c. 160 FU d. 170 FU

79. What is the name of receptacle in which liquids are retained for a sufficient period
to deposit settleable materials?
a. cesspool b. slop sink c. septic tank d. catch basin

80. What is the minimum nominal diameter of a mop sink drain?


a. 2 inches b. 3 inches c. 3 inches d. 4 inches

81. What is the developed horizontal distance of vent from the trap?
a. 3 ft b. 4 ft c. 5 ft d. 6 ft

82. What is the maximum fixture units that can be drained of a house sewer one (1)
foot in diameter with a slope of 4%?
a. 4200 FU b. 6240 FU c. 5040 FU d. 7440 FU

83. What Section in the National Plumbing Code that specifies the size of house,
drains and horizontal branches?
a. Section 240 b. Section 241 c. Section 242 d. Section 243

84. What do you call the flow of water into the water supply system from any source
other than its intended sources?
a. in-flow b. back flow c. siphonage d. back
pressure

85. What do you call the length along the center line of the pipe and fittings?
a. equivalent length b. total length c. developed length d. pipe length

86. What is the minimum branch interval of a soil or waste stack?


a. 5 ft b. 6 ft c. 8 ft d. 10 ft

87. What is the common pipe to be used for change of direction from horizontal to
horizontal in the plumbing system?
a. sanitary tee b. short bend c. wye d. long swept bend

88. The distance between trap and vent should not be more than
a. 5 ft b. 6 ft c. 7 ft d. 4 ft
89. If the vent is near any door, window, air shaft or scuttle of a building, it should be
extend over the highest opening by how much?
a. 3 ft b. 5 ft c. 4 ft d. 6 ft

90. The air pressure in the drainage pipe greater than atmospheric pressure is called
a. back pressure b. air vent c. back siphonage d. none of
these

91. The valve required for hot water tank to prevent excess pressure is
a. relief valve b. check valve c. pressure relief valve d. none
from above

92. The pipe or shaft which is used to remove foul or congested air from a fixtures of
a room and conveys the same to the atmosphere is called
a. ventilating pipe b. crown vent c. local vent d. back vent

93. A vent which also serve as a drain is called


a. wet vent b. local vent c. loop vent d. back vent

94. A fitting or device so constructed as to prevent the passage of air gas and same
vermin through the pipe, without affecting the flow of sewage
a. trap b. stack vent c. trap seal d. check valve

95. The pipe which conveys waste water and water carried waste without fecal matter
a. waste pipe b. wet stand pipe c. vent pipe d. wet vent

96. A vent serving the building drain and public sewer is


a. SVTR b. VSTR c. loop vent d. relief vent

97. The valve which automatically closes the flow of water in a reverse directions
a. globe valve b. check valve c. float valve d. angle valve

98. The greatest stress which the material can stand without permanent deformation is
called
a. ultimate stress b. tensile stress c. working stress d. none from
above

99. A vent for single fixture or battery of fixtures which is connected into the same
stack, into which the fixtures discharge
a. unit vent b. local vent c. wet vent d. continuous vent

100. Identify the method of installation not allowed in a lateral line to avoid
pressure and retardation of flow of waste water causing deposition of solid.
a. sharp curve b. elbow c. gate valve d. cross-connection

You might also like