You are on page 1of 3

Fletcher-Munson kurva

From Wikipedia, the free encyclopedia Dari Wikipedia Bahasa Melayu,


ensiklopedia bebas

Jump to: navigation , search Langsung ke: navigasi , cari

The Fletcher–Munson curves are one of many sets of equal-loudness contours for the
human ear, determined experimentally by Harvey Fletcher and WA Munson, and
reported in a paper entitled "Loudness, its definition, measurement and calculation" in
J.Acoust. The-Munson kurva Fletcher adalah salah satu dari banyak set -kontur
kenyaringan sama untuk telinga manusia, ditentukan secara eksperimen oleh Harvey
Fletcher dan Munson WA, dan dilaporkan di dalam makalah berjudul "Loudness,
definisi, pengukuran dan perhitungan" dalam J. Acoust. Soc Am.5, 82-108 (1933). Soc
Am.5, 82-108 (1933).

Contents Isi
[hide]
 1 Background 1 Latar Belakang
 2 References 2 Referensi
 3 See also 3 Lihat juga

 4 External links 4 Pranala luar


[ edit ] Background [ sunting ] Latar Belakang
The first research on the topic of how the ear hears different frequencies at different
levels was conducted by Fletcher and Munson in 1933. Pada penelitian pertama pada
topik tentang bagaimana telinga mendengar frekuensi yang berbeda pada tingkat yang
berbeda dilakukan oleh Fletcher dan Munson di tahun 1933. In 1937 they created the first
equal-loudness curves. [ 1 ] Until recently, it was common to see the term 'Fletcher–
Munson' used to refer to equal-loudness contours generally, even though a re-
determination was carried out by Robinson and Dadson in 1956 , which became the basis
for an ISO 226 standard. Di tahun 1937 mereka menciptakan kurva pertama sama-
kenyaringan. [1] Sampai saat ini, hal itu biasa untuk melihat istilah 'Fletcher-Munson'
digunakan untuk merujuk kepada-kontur kenyaringan yang sama pada umumnya,
meskipun penentuan ulang dilakukan oleh Robinson dan Dadson pada tahun 1956, yang
menjadi dasar standar ISO 226.

It is now better to use the term ' Equal-loudness contours ' as the generic term, especially
as a recent survey by ISO redefined the curves in a new ISO 226 :2003 [1] . Sekarang
lebih baik untuk menggunakan istilah ' Equal-kontur kenyaringan 'sebagai istilah generik,
terutama sebagai survey baru-baru ini oleh ISO mendefinisi ulang kurva dalam baru ISO
226: 2003 [1] .

According to the ISO report, the Robinson–Dadson results were the odd one out,
differing more from the current standard than did the Fletcher Munson curves. Menurut
laporan ISO, hasil Robinson-Dadson adalah orang aneh keluar, berbeda lebih dari standar
yang sekarang daripada melakukan kurva Fletcher Munson. The report states that it is
fortunate that the 40- phon Fletcher–Munson curve on which the A-weighting standard
was based turns out to have been in agreement with modern determinations. Laporan itu
menyatakan bahwa beruntung bahwa 40 - phon Fletcher-Munson kurva di mana A bobot-
standar ini didasarkan ternyata telah sepakat dengan penentuan modern.

The article also comments on the large differences apparent in the low-frequency region,
which remain unexplained. Artikel juga komentar tentang perbedaan besar terlihat di
daerah frekuensi rendah, yang masih tidak dapat dijelaskan. Possible explanations are:
penjelasan yang mungkin adalah:

 The equipment used was not properly calibrated. Peralatan yang digunakan adalah
tidak benar dikalibrasi.
 The criteria used for judging equal loudness at different frequencies had differed.
Kriteria yang digunakan untuk menilai kenyaringan yang sama pada frekuensi
yang berbeda telah berbeda.
 Subjects were not properly rested for days in advance, or were exposed to loud
noise in traveling to the tests which tensed the tensor tympani and stapedius
muscles controlling low-frequency mechanical coupling. Subjek tidak benar
beristirahat selama hari sebelumnya, atau terpapar suara keras dalam perjalanan
ke tes yang tegang dengan tensor timpani dan otot Otot stapedius mengendalikan
frekuensi rendah kopling mekanis.
[ edit ] References [ sunting ] Referensi
1. ^ http://www.system1audio.com/fmc.html FMC, Fletcher Munson Compensation
^ http://www.system1audio.com/fmc.html FMC, Fletcher Munson Kompensasi

 Harvey Fletcher and WA Munson, "Loudness, its definition, measurement and


calculation" J.Acoust. Harvey Fletcher dan Munson WA, "Loudness, definisi,
pengukuran dan perhitungan" J. Acoust. Soc Am. 5, 82–108 (1933). Am Soc. 5,
82-108 (1933).

[ edit ] See also [ sunting ]

You might also like