You are on page 1of 17

Chassis Part Symbol Defective Circuit Symptom solution

Dead set. Found cr4118 burned in half. Replaced cr4118 and c4 145. Unit still
dead.u4101-16 is pulsing dc. Lifted cr4101-c and injected 12vdc and u4101 runs. As soon
ctc169PF T4102 Regulator as ac is introduced to the supply , it dies.Replacing t4102 repaired the unit. Replace t4102

Hot will fail any where from a few minutes to days. Tech reported that c4145 in the 15v
line was leaky. There was a 3v peak noise spike on 15v line. It was distorting horiz drive
through t4301 and causing q4401 to fail.Replaced c4145 and horiz drive distortion
PTK169PX C4145 Regulator disappeared Replace c4145
Resolder
connections on
Repeat failure of q4101 and u4101. This set would work for several months and come cr4105, replace
back in with the regulator ic and output transistor shorted. Found that the solder q4101 and
CTC169 Q4101 Power Supply connection on the diode cr4105 was never soldered. The output transistor would run warm u4101.

No video 143 volt line low. Traced fault to q4107 pwm amplifier be short). regulator
CTC169 Q4107 Power Supply u4101 had no pwm feedback pulse at pin 2. Replace q4107

T4101 squeals on high brightness scenes. By spraying cold spray around the run
regulator section we could change the tone of the squeal. Found r4143 checked good out
CTC169 R4143 Power Supply of circuit but installing a new 2.2k ohm resistor cured the problem. Replace r4143

Q4101 would heat up and short out. The servicer had changed the parts in the collector
CTC169 C4110 Power Supply circuit of q4101 except for c4110.Replacement of c4110 cured the problem Replace c4110
Shutdown immediately after power is turned on. Regulated b+ was running 190 volts in
the standby mode. The feedback to pin 6 of u4101 was 2.3 volts, normal. The dc voltage
at the cathode of cr4106 was 15 volts and it normally runs around 8.2 volts. Found r4102
ctc169 r4102 Power Supply had increased in value from 5.1k to 11k ohms. Replace r4102
Set shuts down intermittently when channel changed or on some picture content
changes. The reg b+ was up to 147 volts. Cr4123 was leaky making the base of q4111 to
CTC169 CR4123 Power Supply high. This raised the reg b+ Replace cr4123
Q4101 runs hot for about three hours then shorts. With TV turned off regulator will run all
day without over heating q4101. Checking waveforms and voltages the only discrepancy Resolder loose
we found was the voltage on u4101-14 which measured 2.6v instead of 1.8v.Corrected connnection on
CTC169 L4101 Power Supply bad solder connection on l4101 (u4101-14). l4101

When power button pushed, the 143 volt supply dropped to 70 volts. The 200v supply did Replaced
ctc169pf c4702 Power Supply not come up. Found c4702 shorted across cr4701. c4702.

Dead. Grounding the collector of q4304 the set would not power up. Checking pin 26
u1001 revealed 0 volts. Checking the collectors of q4301 and q4305 checked 5vdc.
Checking the emitter of q4305 we had 0 volts.Checking zenner diode cr4303 showed it
CTC169 CR4303 Power Supply was shorted. Replacing the diode repaired the set Replace cr4303

Tv had an intermittent shutdown a few weeks, than dead. Plugging in tv without turning it
on the voltage on u4101-16 bounced between 7 & 10 volts. Disconnecting secondary
supplies from t4102 the voltage on u4101-16 continued to cycle.Replaced cr4101 (t4102-
CTC169 CR4101 Power Supply 13) which checked ok. Replace cr4101

Set won't come on if you press the power button within 30 seconds of plugging it in. The
servicer noticed that the regulated b+ comes up slowly. The vcc at pin 16 of u4101 also
comes up slowly. By substituting c4118 this voltage came up immediately when plugged
ctc169 c4118 Power Supply in, and fixed the unit. Replace c4118.

No 15 volts off of cr4118 no stand by 15 volts. Other stand by voltage were key.Found
q4107 the pwm amp. Was leaky pulling down the 15 volt supply this is the second set I
CTC169 Q4107 Power Supply had with a bad q4107. Replace q4107

Bright picture with retrace lines. Loss of 200 volts to kine socket. Trace loss of 200 volts
CTC169 C4716 Power Supply to an open c4716. Replace c4716

The set would power up without any video. On q2906 (e) the voltage measured
1.3vdc.the 12vh supply which supplies this transistor through r2947 and r2930 was
CTC169H missing. Making a continuity test between jc415 and jw409 there was an open. Repairing
M JC415 Power Supply the foil between jc415 and jw409 repaired the set. Repair trace
ctc169 c4146 Power Supply Standby power cycles on and off. Found c4146 shorted. Replace
Replace c4146
ctc169 CR4101 Power Supply Dead no b+ to u4101-16.Cr4101 shorted Cr4101
Dead set unit won't start up. Stand by voltages ok. No 9 or 12 volt run supply. When
checking for the 26 volt source we found it was missing on one side of l4702. L4702 was Replace u4801
CTC169 L4702 Power Supply open. The open side was shorted to gnd. Traced it to u4801-8 which was shorted. and l4702

At turn on set would flash a gray raster then shut down. Grounding collector of q4304
gave us gray raster with 4v on 9v source. Traced problem to q4705. Had 8v c 0v b + e.
We removed q4705 and voltages returned to normal. Pushing the power button brought
ctc169 q4705 Power Supply up video and audio. Replace q4705

Would shut down when turned on. Jumping pin 2 of u4101 to ground would get set on
and normal for this situation. Q4105 b+e looked ok when run this way but were .5v low
when turned off. Without pin 2 jumped reg b+ would momentarily increase to 170v before
ctc169 c4115 Power Supply shutdown occurred.Replacement of c4115 off of base of q4105 repaired set. Replace c4115
After the set warms up the picture will jump, gets vertical jitter, then the video blanks Resolder loose
CTC169C out.Found poor connections at R4719 in the collector circuit of Q4705. Located on the connections on
A6 R4719 Power Supply CBA at 15CC. R4719
Set came in with postage stamp appearance and reg b+ was very low approximate 110v.
Checking the error amp voltages on q4105, we found that even though we had saturation
on q4105, the collector was only 1.5v with a 4.3v emitter. Lifting the collector on the
transistor gave us 4.8v emitter and collector. Resistance from q4105 to ground was 179
CTC169 C4136 Power Supply ohms. Replace c4136
Set pulses on and off continuously. B+ drops to 115v. Found that with out the cable
attached the set would stay on for 30 seconds with a small snowy pix before starting to
pulse. On pin 2 of u4101 we had hor spikes with lots of noise while the set was not
pulsing. We traced the problem to r4144. The resistor measured 9.5k. Replacement cured
ctc169 r4144 Power Supply all problems. Replace r4144.
The set comes up and then shuts down. The voltage at q4702-b measured 5 vdc and the
ctc169BU Q4702 Power Supply emitter was 3 vdc. Replacing q4702 restored normal voltages. Replace q4702
Dead voltage at u4101-16 measured 7 volts. Signal at pins 10 and 14 pulsed on & off. 0
CTC169 CR4118 Power Supply volts at q4401-c (hot).Replaced shorted cr4118 (t4102-3) Replace cr4118

Squeal coming from chopper transformer. Turning down brightness and contrast or
CTC169 C4139 Power Supply cooling r4143, squeal disappeared.Replaced open c4139 (near q4106-b). Replace c4139
Set had low b+ of 118 volts. Raster was pull in all 4 sides Q4111 transistor in power
CTC169 Q4111 Power Supply supply was open. Replace Q4111

Unable to turn the set off as long as the set is connected to ac the hv and filaments stay
on. The voltage at q4301-b only comes up to .6 vdc. The source for the base voltage
comes from the 15 vdc standby via r4127, jw336 r4309. R4127 was open. Note: the .6
CTC169 R4127 Power Supply vdc won't bias q4301 into saturation. It must be .7 vdc. Replace r4127

Pix intermittent blank. Original complaint was convergence. Looked at u7005 and found
11v b+. Found regulator output at 33v on 45v line. R7147 (b+ adjust) brought up the
correct voltages but was turned all the way up. Found on u7004 pin 2-1.8v, pin 1 - 3.3v,
and pin 8 - 7.5v. After several checks it appeared that pin 8 being high was the fault.
ctc169 u7004 Power Supply Replacement of u7004 and readjusting the b+ pot returned the set to normal. Replace u7004

CTC169 C4118 Power Supply TV intermittently wouldn't start servicer found an open c4118 (470uf at u4101-16). Replace c4118
Had no 15 volts off diode cr4118. Volts measured 1.5 volts at the cathode of cr4118. Had
a 50 volt p to p on the anode of cr4118. The diode had been replaced and all the feeds off
the cathode had been open. Lifting the anode and jumping it to pin 1 of the transformer
we had 16 volts on the cathode of the diode.The transformer t4102 had a bad winding
CTC169 T4102 Power Supply from pin 3 to 4 Replace t4102

Set would shut down as soon as power button pushed. Defeating the regulator would
allow the set to run at rated b+ of 143.5v. Checking the run regulator error amp q4105
CTC169 R4114 Power Supply found the 4.62v missing at the base. R4114 45.3k resistor from the 143.5v line was open Replace r4114
Narrow picture and regulated b+ was 127 volts. Replaced t4101, both primary and
CTC169 T4101 Power Supply secondary was open. Replace t4101

Audio ok no video found reg b+ at 110v. No pulses at pin 2 of u4101. Q4107 had no
voltages on any lead. Found q4111 with open collector cutting off voltage to error
ctc169 q4111 Power Supply amp.Changed q4111 and set returned to normal. Replace q4111
Tech replaced shorted q4101. Turning on tv, all the chopper output voltages were ok.
However, turning off the tv the 143v supply went to 165 volts.Replaced open c4108
CTC169 C4108 Power Supply (q4101-b). Replace c4108
Raster pulled in on sides and top b+ low 88 to 108 volts. Could not measure waveform
on base of q4106. Going back we had wave form on one side of r4144 not on other.
ctc169 r4144 Power Supply Checked resistor should be 1.8 k measured 2 meg. Replace r4144
Intermittent shutdown run regulated b+ was running high at 149v.Found zener diode
CTC169 CR4123 Power Supply cr4123 (5.6v) zenering high. Replace cr4123
CTC169 T4102 Power Supply Set shuts down. Faulty t4102 (open winding, pin 12 and 13). Replsce t4102
Dead set. the 15 volt source in the power supply was down to 8.9 volts.Replaced a leaky
CTC169 C4145 Power Supply c4145 (circuit off the pin 3, t4102). Replace c4145
Dead set u3101 pin38 would go high then low with out any response from TV.Cr4606 was Replace
ctc169 cr4606 Power Supply 8.6v instead of 5.6v causing 5v stand by to be 3v high. Cr4606
Shutdown has to be unplugged then when tried again high voltage comes up and a snap
is heard and tv shuts back down. Servicer found that noise was coming from ac cord.
Replacement of cord repaired set. Swapping the old cord back on the tv brought back Replace ac
ctc169 line cord Power Supply symptom. cord.
Ticking noise heard with the set off. Ticking noise was coming from the ptv aux regulator.
CTC169 Q7050 Power Supply Found q7050 open. Replace q7050
No picture, no audio for osd there are blocks instead of characters. The only viewable
graph was for volume which was smeared. No +5vb on u3200-8.Corrected solder Resolder loose
connection on jw325 (q4703-e +5v run). Open jw325 removes voltage to 5vb, 5vc, 5vd, connection on
CTC169 JW325 Power Supply 5ve & 5vf. jw325
The set would have what appears a "double "picture that has a slight tearing. Found that
l4101 (connected to pin 14,u4101) in the power supply was breaking down internally (
CTC169 L4101 Power Supply shorting).Replacement of l4101 repaired the set. Replace l4101
Set would play for about 30-40 sec and then lose pix and sound. Screen would be black
but osd would still function. Checking voltages around tuner we found the 5v line down to
1v and pin 7 line at 1v pin 8 was at 5v. Going to q4703 we found 5.9 at the base, 13v at
CTC169 Q4703 Power Supply collector and emitter was at 1v. Replace q4703
Unit was effectively dead. Found that isolating the system control we could fire the rest of
the set. Checking around u3101 found 5v standby source low down to 3.28vdc. Cr4118 in
the power supply was providing 13.2vdc in standby mode. Lifting cr4710 restored proper
5v standby. The diode was leaky causing excessive current draw through the 12v run
CTC169 cr4710 Power Supply supply. Replace cr4710
"Noise in frame around pip pix. Sometimes in big pix. Sometimes pip has ""digital"" noise
in it. Found that freezing q4703 had an affect on the symptom. The transistor had 5.9
CTC169B base and 5.3 emitter. Changed cr4709 and emitter voltage dropped to 4.9v. Problem went
G2 CR4709 Power Supply away." Replace cr4709

Hard shutdown after a brief second of high voltage. In the standby mode, the 15v
(cr4118) line read 12.35vdc. When we jumped out the power supply to force on the
horizontal stage after extensive static checks, this diode shorted at turn on in the forced
CTC169 CR4118 Power Supply condition. Replacement of this cr4118 fixed the set. Replace cr4118
When set was off the voltage of diodes cr4116 and cr4118 was okay but when set was
turn on the voltage off the diodes was low.Found r4144 off pin 7 of ihvt was open. Pin 7
CTC169 R4144 Power Supply feeds a 30 volt pulse to q4106 the pwm generator. Replace r4144
Picture small regulated b+ at 115vdc. Pwm pulse missing off pin 2 of u4101. Found open
CTC169 R4143 Power Supply resistor (r4143). Replace r4143
Dead set no standby voltage. Monitoring pin 8 of u4101 while plugging in the set we
found that the set was in over current shut down. After checking the secondary of the
transformer for shorts we found none. Found a shorted resistor r4109 off of the emitter of
ctc169 r4109 Power Supply q4101. Replacement brought back operation of set. Replace r4109.
Intermittent dead flexing the board in the regulator circuit and/or freezing the reg. Chip
ctc169 u4101 Power Supply would make the chip start and stop. Replace u4101
Dead set - no regulator operation drive waveform was not present at pin 14 - u4101.
Supplying an external 12 volt dc at cr4101 cathode - no drive waveform at pin 14. The
20khz saw tooth was present at pin 10 (u4101) and only a .06 dc level change was
detected at pin 14. Checking c4105 on pin 9 we found the cap measured 4k. Out of
ctc169 c4105 Power Supply circuit, it seem to check ok Replace c4105
Intermittently a "bull's eye" impurity pattern will develop. Traced fault to an intermittent
CTC169 plug Power Supply plug connecting to the degaussing coils. Replace plug

Intermittent shutdowns, There was no particular time frame or temperature that the
symptom would follow. It lasted for 2 weeks without failure on continuous play. We noted
that even during normal operation that the 15v supply was down to 13.2 with 1.5 ac,
ctc169 c4145 Power Supply Noted at the start of the failure ac on 15 vdc was 6vac. Replace c4145.

Small picture with three inch black on all four sides. Regulated 143v measured 119v.
CTC169 T4101 Power Supply Very little signal on u4101-2. Replaced t4101 with an open winding between pins 4 and 5. Replace t4101
Dead on u4101 pin 16 staying at 8.2v. Pin 15 10.4v.Checking r4150 checked good.
CTC169 R4150 Power Supply Replacing r4150 fixed set. Replace r4150
Narrow picture and bowed in on the sides. Regulated b+ was low at 115v. U4101-2 was
missing the horizontal pulse.Replaced open r4144. R4144 couples a horizontal pulse over Replace r4144.
ctc169 R4144 Power Supply to the regulator and the pincushion circuits. R4144

Dead found stand by 143v at 80v. 15v at 14v in stand by. Replaced c4141 off of cr4116
ctc169 c4141 Power Supply cathode. Replace c4141
Osd characters shifted to the right. Found b+ to ic3200 pin 8 to be 5.25v. 5v stand by
volts was at 5v. Found cr4709 in base circuit of q4703 to be leaky causing 5va source to
ctc169 cr4709 Power Supply be high. Replacing cr4709 repaired set. Replace cr4709
Color fades at times. this can happen after you change a station. this can be intermittent
at times. traced fault to cr4118 breaking down slightly. the voltage at the was about 10-11
CTC169 CR4118 Power Supply volts. Replace cr4118
Picture linear, but small had no waveform on pin 2 of u4101, regulator ic.Traced to
missing 30v pulse at the cathode of cr4115. Found cr4115 and cr4121 shorted and Replace cr4115
ctc169 cr4115 Power Supply replaced them. and cr4121
Unit keeps blowing u4101 and q4101 when unit was plugged in. Tech hit c4152 and it
CTC169 C4152 Power Supply came apart. Replace c4152
Small picture no horizontal pulses at transistor q4106, this resulted in the loss of pwm at
CTC169 R4144 Power Supply u4101-2. R4144 is in the 90/30 v pulse line from t4401-7. It was open. Replace r4144

CTC169 CR4119 Power Supply Dead power supply in over current shutdown. Found cr4119 shorted. Replace cr4119
No pip functions, found that the 12v run and 5v run were both 2v too high. Replace
CTC169 cr4606 Power Supply defective cr4606 had increased to 7.7v zener. Replace cr4606
Black. Band across screen that moves from top to bottom. Convergence out. Found bc
CTC169 Q7051 Power Supply short at q7051, no 16 volts to u7004. Replace q7051

Shut down after warm up cr4709 goes leaky. 5v run volts goes up to 5.2v or more
causing various symptoms. Most common is blocks instead of on screen display. Have
ctc169 cr4709 Power Supply seen problems such as erratic or inoperative control panel and intermittent shut down. Replace cr4709

Replaced
CTC169 CR4101 Power Supply Dead. Two volts on u4101-16. shorted cr4101.
Replace all the
Q4101 blows at turn on. Replaced q4101, u4101, cr4122, r4001, and f4001. TV operated above parts
in standby just fine but when the set was turned on all the new parts blew out again. again plus
CTC169 R4110 Power Supply Replacing all the above parts again plus r4110 fixed the TV. r4110
Four sided shrink. Poor regulation regulated b plus in run mode was 118v. No horizontal
sync. In stand-by b plus 140v. Found r4144 (off pin 7 of fly back) open. After replacing
still poor regulation. Checking r4116(b plus adjust) found resistance had increased as per
CTC169 R4144 Power Supply factory notice due to glue in r4116. Replace r4144

CTC169PF r4115 Power Supply Checking q4105, found base at 5.3v traced back to r4115 increased in value (1.5m) Replace r4115
Dead set would not power up. Checking in regulator power supply found that our run
supplies would not come up by turning our on/off buffer (q4304) on. Tracing back to the
12 volt run supply (q4702) we couldn't get any base voltage. Found a open trace from the Repaire broken
CTC169 PCB Power Supply base of q4702 to r4714. trace

CTC169PF No video with all three tubes connected. You could disconnect any of the three tube and
A Q4107 Power Supply you would have video. Found q4107 in the pwm circuit leaky Replace q4107
At plug in the set would pulse 4-5 times and then dead. Would have to unplug the set
and wait until u4101-16 drained off before plugging the set back in only to hear it pulse 4-
ctc169 CR4118 Power Supply 5 times and be dead. Found cr4118 shorted causing over current shutdown. Replace cr4118
Set came in with a small picture. Replaced the regulator ic (u4101) the set won't turn on.
The tech didn't soldier pin 14 of u4101. That cause e q4101 to short and r4150 to open
and killed u4101. After replacing those parts had a small picture. Checking in the pwm Replace u4101,
circuit found a leaky q4107 pwm amp. Replace defective u4101, r4150, q4101, q4107 r4150, q4101,
CTC169 U4101 Power Supply restored normal operation q4107
Unit is pulsing off and on made the normal checks. Regulated b+ safety cap, crts hv
block, focus block etc.. Went over to u3101-2 and measured 0 vdc I found this was via
r3349 to q1915 collector (schematic q1914) the transistor was in saturation. U1903-11
was missing the neg 17vdc. This is source from the pwr supply cr4120 anode. The diode
CTC169 CR4120 Power Supply was open. Replace cr4120
Set had good standby voltages, but b+ would go excessive and shutdown when turned
ctc169 q4105 Power Supply on. All 3 legs of q4105 read 5.1vdc. Replace q4105.
Small picture; pulled in on all sides. Regulated b+ voltage was running at approximately
118v when the set was turned on. Checking voltages in the error amplifier pwm
generator/amplifier: q4106-c - 2.6v q4107-c - 0v. Found t4101 open internally at pin 2.
The technician said he was able to resolder the winding lead to the pin and restored
CTC169 T4101 Power Supply normal operation. Replace t4101

Dead, no stand by voltages. Pin 8 would pulse up when unit plugged in. We put external
11v on pin 16 of u4101 w/o ac applied. The chip had no output. Pin 8 went high indicating Repair ground
over current shutdown. Lifting r4109 we could get the chip to run but had 8vdc on pin 14. side of r4110
The dc voltage (pin 8) was intermittent. Traced problem to ground. Repair ground side of and pin 12 of
ctc169 trace Power Supply r4110 and pin 12 of t4102. The copper run had a break in it. Repair of trace repaired set.. t4102.

When the set was in the run mode the power supply would make a squealing sound,
standby it was fine & the reg b+ was not being affected however. Scoping q4106(c) there
was garbage present, the emitter had a trapezoid type waveform on it with the dc voltage
ctc169 C4136 Power Supply slightly higher (5.1vdc) on the emitter and 4.7vdc on the base. C4136 fell apart Replace c4136
Tv won't start. The power supply runs in standby. Pressing the power button causes the
143v line to drop to 70v, the 15v line to drop to 0v, and u4101-16 to drop to 8v. These
supplies would drop momentarily and come right back up. Disconnecting the hv lead to
ctc169 R4704 Power Supply r4704 let the set come on. Replace r4704.

No picture- reg. B+ was 109vdc. Servicer found that if he dis- connected one of the crt
sockets, he could get a dark, small picture. Heating r4143 caused its resistance to vary
CTC169 R4143 Power Supply from 1.5k to open. Replacing r4143 restored normal operation. Replace r4143
No picture on all channels, rushing noise only on low vhf and good sound on high vhf
channels. Found +5 volts on pin 5 of the tuner instead of -11v. Replaced open l4701
CTC169 L4701 Power Supply (t4401-7). Replace l4701
Ptv aux supply squeals in off mode. Found q7051 shorted all the way around. Servicer
ctc169pd Q7051 Power Supply had another set doing same and confirmed same part. Replace q7051
No start. Would pulse on and off in standby the 140v down to 127v. When on command
keyed the 140 would start at 127 and bleed down. Replacing c4141 cured problem.
CTC169 C4141 Power Supply Checking c4141 it read 20uf. Replace c4141
Picture flashes. Scan loss detect circuit is active and cycling on and off. Found that the
ptv aux power supply was also cycling on and off. Adding 16vdc to cr7064 restored
normal operation. Cr7064 checked good in and out of circuit. Replaced defective cr7064
CTC169 CR7064 Power Supply and restored normal operation. Replace cr7064
Intermittent to no color. Found u1001-14 at 8.1v. Checking in regulator circuit found the
26v supply from ihvt pin 8 at 21v. Servicer found cracked trace from l4702 to c4705. This
CTC169 trace Power Supply crack was by a twist tab for the horizontal output heatsink at grid location 15i. Repaire trace
Top 3/4 of picture is blanked. Unplugging any crt, video returns on the other two tubes.
CTC169P Scoping the video to the crt you could see that the video was being blanked. Found
G CR4118 Power Supply u1001-14 at 7.45v, cr4118 was at 10.1v. Replaced cr4118 Replace cr4118
Dead set. Grounding pin 2 of u4101 (regulator) the set would run in the standby mode.
The pwm pulse on q4107 (pwm amp) base and collector look normal for the standby
CTC169 U4101 Power Supply mode. Replaced u4101 regulator ic restored normal operation. Replace u4101
Intermittent shutdown and come back on. At the moment of failure the regulated b+ was Replacement of
at nearly 170vdc. We then grounded pin 2 of u4101 and monitored the error correction cr4111 fixed
CTC169 CR4111 Power Supply and pwm circuits. We found that the error amp reference voltage at q4105 emitter was the set.

Pulled in on all sides, no color, no horizontal sync. Found cr4115, cr4121 shorted. R4144 Replace cr4115
ctc169 cr4115 Power Supply had increased in value. Replaced parts. , cr4121 R4144
Pix bright with retrace lines. 200v supply low. 200v was 60 v with kine socket connected
and dropped to 9v when kine socket pulled. Pulse from pin 10 of fly back was ok but not
CTC169 C4716 Power Supply getting through open c4716 Replace c4716
Intermittently the picture became very bright with retrace lines and no picture. 200v
supply drops to 98 volts and the 26v source dropped to 17v. Replaced cr4702 (near t4401-
CTC169 CR4702 Power Supply 10) which checked ok. Replace cr4702
Negative pix for the first 5 minutes of operation. If you select the pip function within the
first 5 minutes the problem would clear. If the set was left alone for 5 minutes the problem
would clear checking the voltage drop across diode cr4709 found .3v drop. The 5v from
this power supply goes to the comb filter circuits among other circuits in the set .
CTC169 CR4709 Power Supply Changing cr4709 cured the problem Replace cr4709

Raster about 4 inches short on all four sides. Very small waveform on u4101-2. The
waveform on the collector of q4107 was a sawtooth instead of a pulse. The resistance
CTC169 T4101 Power Supply across the primary of t4101 measured 6 ohms, should be 10 ohms. Replace t4101.

Set would turn on and off but the power light would stay on. Regulator had 10v on the
15v line in standby. Found q4704 to have 5v b, 4.5v e, and 9v c. Q4702 had 10v c, 7v b,
ctc169 q4702 Power Supply and 9v e. All voltages taken in stand by. Replaced leaky q4702 and repaired set. Replace q4702
Negative looking picture. No color. while trouble shooting in the video circuits, noticed
that the 12 volt run source was down to about eight volts. Traced fault to a defective 12
CTC169 Q4702 Power Supply volt run transistor q4702 (shorted). Replace q4702
All pip functions operated except the zoom function. Servicer tried another pip mod.
Checking pin 8 of u3200 the b+ voltage was up to 5.6v. Checking cr4709 it had a .3v dc
CTC169 CR4709 Power Supply drop across it. Changing the diode (cr4709) the set regained the zoom feature. Replace cr4709

Small pix rolls thru the big pix and then fades out. Replaced the pip module and it didn't
fix the set. Found the 5 volt line at j8001 pin 10 was 6.3vdc. Going back to the 5 volt run
source in the power supply found q4703 had 7.1 volts on the base, caused by cr4606
CTC169 CR4606 Power Supply zenering at 6.8 volts. This is a 5.6 volt zener diode. Replace cr4606

Set shuts down when hv comes up. Q4105 goes into saturation. The regulated 143vdc is
at 111vdc. The problem was with q4105 going into saturation. This was caused by c4115.
It would break down under a load and forward bias the b-e junction. You can lift the cap
CTC169 C4115 Power Supply and test the set to verify this is the fault. Replace c4115
Dead: checking with tech found that if grounding collector q4304 chassis would turn on.
Tech had replaced u3101 no effect. Checking voltage on pin 19 u3101 found 0v.
Checking emitter q4601 @ 0v & collector @ 12v & base @ 0v. Found cr4606 5.6v zener
CTC169 CR4606 Power Supply in 5v standby shorted. Replace cr4606
Vertical jitter after warm up. Found cr4712 off the emitter of q4704 the 9 volt regulator
CTC169 CR4712 Power Supply was thermo. Replace cr4712
Dead set. pulses three times and shutsdown. found q4702-e not getting any voltage to it. Resolder loose
found no dcv at q4702-b either.q4705 was not turning on. Found a bad connection at connection at
ctc169CF5 JW334 Power Supply jw334. jw334
Bright picture 200v source missing. R4720 off t4401-10 opening under load. R4720
ctc169ac r4720 Power Supply checked good out of circuit. Replace r4720.

Set would pulse three times and quit. The servicer isolated the focus screen control and
horiz circuit and they checked ok. The servicer grounded q304 (collector) and high
CTC169B voltage came up. The 9vdc regulator q4704 was not working (base and emitter were
K R4715 Power Supply 0vdc). R4715 (200 ohm) was open. Replace r4715
CTC169P Standby voltages from the regulator are high. 140 volt line would jump up to 210 volts.
C C4105 Power Supply Traced fault to open c4105 off pin 9 of u4101. Replacement fixed the set. Replace C4105.
Small pix. Originally servicer said he had a black line on right side of pix. Found the 9v
line at 8v. Traced problem to power supply running in stand by. R4152 off of the emitter Replace r4152
ctc169 r4152 Power Supply of q4111 was open. Replacement cured power supply problem but pix was now too big. and aligned set
No color. Found the 143v line at 131v. Pix size and audio ok. Voltages in the pwm circuit
looked close except the 4.7v zener, cr4111, had 4.3v on its cathode. We subbed it and
ctc169pa cr4111 Power Supply the voltages returned to normal and color returned. Replace cr4111
Smeared video-retrace lines/ q2906 had been replaced measured g1 at 9vdc, g2 normal,
and 200v source was 90vdc with 20v ac. Checked 200v source on chassis and found
CTC169 C4703 Power Supply c4703 open. Replace c4703
Dead set, standby voltages high { 143 was at 200}. Set would not turn on. Voltages on
CTC169JS u4101 were near normal. Base of q4101 was at .05 {should be -.19} replaced c4108 and
6 C4108 Power Supply standby returned to normal and set turned on. Replace c4108

No picture, ptv aux supply not running. With the set on u7004 pin 7 was at 15.8v and all
other pins of u7004 were at 0v. With the set turned off cr7074 was zenering at 18v.
Installing a new zener it zenered at 23v and when we hit the power button u7004 fired up.
CTC169 CR7074 Power Supply U7004 pin 7 needed that extra little kick to get started. Replace cr7074
No pix going through u1401 video switch. The voltages around this ic were all low. If you
lifted the ground pins 12,14,15 or pin 5 (aux 2 input ) the chip would work. Found the
+12vm source at 9v in standby. This voltage should not be present until the scan 26v is
up. Checking q4702 we found it leaky. Replacement cured problem. This problem has
CTC169 Q4702 Power Supply been seen several times before. Replace q4702
Splotches on sides in the raster pix blanked on both sides in splotches like you had
thumbs on the side of a photograph. On the aux board off the b+ adjust contr ol r7145 had
CTC169 R7145 Power Supply increased in value to 2k ohms. Replace r7145

Dead set- horiz vcc at u1001-26 never came up. Q4305-e never came up. When
CTC169P checking q4305-b voltage checked 9.6v, set came up, and emitter was at 9v. Tech
D Q4305 Power Supply checked q4305 base circuit and found that the base leg was broken at the transistor body. Replace q4305.

Set would shut down at turn on. Would run with run regulator defeated. Voltage at the
emitter of q4105 was high ( 5.6 ) checking the voltage at cr4111 it was 4.7v. Checking
CTC169 CR4112 Power Supply back we saw a 1.2v drop across cr4112. Replacing cr4112 cured the problem. Replace cr4112
The standby supply would cycle from current draw to no current draw. If the power button
CTC169PT is pressed during this time the set would start and run fine. If the supply was left to cycle it Install c4102
A C4102 Power Supply would go dead after 10 seconds.Found c4102 inserted backwards correctly
Power supply has 160v on 143v line. Power supply shuts down at turn on. Unplug and
power supply comes back up in standby. Pin 6 of u4101 was normal but pin 7 was high.
The chip and every thing associated with pins 6 and 7 were changed. In standby all
secondary voltages were high except on cr4119. This voltage was low. Replacement of
ctc169 cr4119 Power Supply cr4119 brought all volts back to normal. Replace cr4119
Had no video or sound from tuner or when signal was injected at the video and audio
jacks. Found no -12 volts to the tuner and no -12 volts to video switch ic1401. Coil l4701
CTC169 L4701 Power Supply off pin 7 of t4401 which is the -12 volt line was open. Replace l4701

Dead set with r4102 5.1k 2% smoking. U4101 regulator pin 6 measured 15volts, and pin 7
had 8.5volts. Found 163 volts on pin 13 of t4102 due to the two primary windings being
CTC169ej shorted. (0 ohms). Replacement of t4102 restored normal operation. Servicer has already
5 T4102 Power Supply replaced the regulator u4101, h-out q4101, and the main fuse f4001. Replace t4102

ctc169 CR4303 Power Supply Horizontal jitter. The 9v to u1001 pin 26 was low. Replace cr4303 Replace cr4303
Dead set. found the voltage at pin 16 was 8volts instead of 11 volts. found r4150
CTC169 R4150 Power Supply breaking down under load. Replacement of r4150 repaired the set. Replace r4150
Q4101 and u4101 shorts intermittently. The snubber network had already been changed.
CTC169 R4003 Power Supply Found intermittent r4003 (off pin 16 u4101) Replace r4003
Horiz b + was 144 volts in standby but went to 128 when set was turn on. Q4105 base and
emitter check ok but coll. Was down to 2.2 volts when set was turn on. Found q4109 was
CTC169 Q4109 Power Supply leaky from coll. To emitter Replace q4109

Set would turn on and run all day. When turned off the power supply would shut down
regardless of amount of time the set had been on. Pin 16 of u4101 was bouncing. After
unplugging so to discharge and reset the circuit the set could be plugged in and turned on
with no problem until turned off. When supply was on we found no indication of
ctc169 u4101 Power Supply abnormalities. Replace u4101

CTC169 C4102 Power Supply Standby reg b+ measured 200 volts. Replaced leaky c4102 (near u4101-6). Replace c4102

In standby the reg b+ is at 230 volts. Found by jumping pin 2 of u4101 to ground, the
standby voltage would hold at 170 volts. Found q4105 and q4111 both shorted. After Replace u4101,
replacement the standby was still at 170 volts. Found pin 14 of u4101 measured 42 ohms. q4105 and
CTC169 U4101 Power Supply Replace u4101, q4105 and q4111. q4111.
Set dead. 143v ok in stand by. Jumping q4304 the 143v line drops to 70v. U4101 running
but q4101 (according to servicer) has large negative going spike along side a positive
ctc169bg5 c4118 Power Supply going spike. Found that c4118 measured 320uf. Replace c4118
Power supply in the convergence circuit is pulsing on and off. Found an open l7004.. All
the voltages read high from the power sup ply.. The supply would not run unless all the
ctc169PG l7004 Power Supply diodes where lifted. Replace l7004..
CTC169P Dead set. Pin 16 of u4101 pulsing 8 to 11vdc. Found t4102 pins 12 with 130k ohms to
E T4102 Power Supply ground. Changing transformer cured problem. Replace T4102

Tv turns off immediately after being turned on. Forcing the high voltage up by grounding
CTC169P the collector of q4304, checked pin 2 of the micro and it was still low. Back at the 9v
E R4710 Power Supply regulator, q4704, collector voltage. Found r4710 open off of collector of q4704. Replace R4710

Picture flashes on & off at turn-on. R7037 in the green vertical convergence circuit
overheats. The technician had replaced q7007, 8, 9, 10, 11 & 12, u7001 and several
CTC169PT diodes. Checking the +15v at cr7061, it was pulsing 0v to +.6v. The -15v supply at cr7062
V CR7062 Power Supply was pulsing -.6v to +.3v. Cr7062 was open and a replacement restored normal operation. Replace 7062

No picture. Found q7037 (ptv aux power supply) shorted and r4001 open causing a dead
set. After replacing there was no picture. Found scan loss circuit active .Found that there
were no outputs from the switching power supply. There was output from u7004 pin 6 to
CTC169PT CR7057 Power Supply q7037. Fpund cr7057 shorted. Replace cr7057
No color. Pin 30 (color killer) ic1001 at 3v. Found that pin 14 (vcc) was at 5v. Traced
ctc169bd5 r4710 Power Supply problem to r4710 off of the collector of q4704. The resistor was up to 30k. Replace r4710.
CTC169A Dead set- 5v standby line was at 2.8vdc, found r4602 at q4601c-b open. Replacement of
H R4602 Power Supply r4602 repaired set. Replace r4602
Set was dead. When you plug into ac heard a buzz from power supply area but no stand-
by voltages were present. When the regulator was bypassed the set worked normally.
Changed most every component in the shut down circuit of the regulator ic. He put
CTC169JS another .33 cap across u4101-9 & ground and the power supply came to life. The c4105
5 C4105 Power Supply in set checked 29pf. Replace c4105
When trying to autoprogram in the air mode, set would switch to cable mode. The voltage
on u3200 pin 8 (vcc). It measured 5.24 volts. Traced back to the 5 volt run circuit and
CTC169 CR4709 Power Supply checked cr4709. The anode was at 6.2, but the cathode was at 5.9. Replace cr4709
CTC169C The chopper output, q4101, would overheat and short after the set played with no
F5 C4108 Power Supply apparent problem for 3- 4 minutes. Replaced c4108 in the base circuit of q4101. Replace c4108
CTC169 CR4116 Power Supply No unregulated b+ on the horizontal output. Replaced a defective cr4116 Replace cr4116
Bright picture with retrace lines.the 200 volt source to the kine circuit was low.found an
CTC169 C4703 Power Supply open filter c4703 (that connects to the cathode of cr4701). Replace c4703.

ctc169 c4145 Power Supply Dead. 15v line was 7v in stand by. C4145 was in the circuit with polarity reversed. Replace c4145.
No picture or osd, but sound and high voltage ok. No voltage on u7004 pin 7. Also, no
CTC169P voltage on q7051. Disconnecting parts we traced cause to c7063. Replaced leaky c7063
V C7063 Power Supply (q7051-e) which checked 56k out of circuit. Replace c7063
Chassis pulses three times and shuts down. Replaced an open c4102 (located near pin 6,
CTC169 C4102 Power Supply u4101). Replace c4102
Buzzing noise heard from chassis during scene changes. Replacement of t4102 in the
CTC169 T4102 Power Supply chopper supply. Replace t4102
CTC169CL
5 L4101 Power Supply Q4101 was shorted, and replacement overheated. Tech found l4101 open. Replace l4101
CTC169 T7100 Power Supply Lines in picture. High pitch squeal. Replaced t7100 ptv aux supply transformer. Replace t7100
Dead set. chopper supply not operating. voltage at pin 16 of u4101 was low. isolated
CTC169 C4101 Power Supply problem to a leaky cap c4101 (connected to pin 13, t4102). Replace c4101.
Set was dead found 15v changing from 9v-11v had replaced cr4118 and still had the
ctc169cg5 T4102 Power Supply same symptom. Replaced t4102 corrected the problem. Replace t4102
Shuts down. Pulses 3 times and quits. Removal of p1903 would allow set to turn on. Dc
volts on + and - 17v line was +24 and +8v. T4102 had open winding between pin 2 and
ctc169 t4102 Power Supply pin 5. Replace t4102.

Immediate shutdown at turn-on. Lifting jw312 in the vertical circuit allowed the set to turn
on without shutdown, but reg b+ for horizontal at that time was running 165vdc. At q4105,
found no obvious voltage problems. Checking resistance of components in the base
circuit, we found r4148 reading 63k ohms. (it should have been 53.6k.). Replacement of
CTC169 R4148 Power Supply r4148 brought reg b+. Back to normal and eliminated the shutdown problem. Replace r4148
Clock loses time when the set is off, approximately 2 hours over night. While
troubleshooting, this unit started having intermittent turn on problems. Found noise on the
ctc169pt c4102 Power Supply power supply lines when the set was off. Replaced c4102 Replace c4102
Initially, the set would have intermittent loss of color, a white bar (foldover) at the bottom
of the picture, or be dead. Eventually the problem was consistently dead. In
troubleshooting the problem, we found the 15v supply from cr4118 was low and varying.
Replacement of cr4118 brought the set back to operation and no longer were the color or
CTC169 CR4118 Power Supply white line problems present. Replacecr4118

CTC169 C4108 Power Supply Squealing noise in standby. traced fault to c4108 (off the base of q4101). Replace c4108.
CTC169C Video washed out and weak. The vcc to pin 14 of u1001 slightly low. Resoldering pin 8 of Resolder pin 8
A6 connection Power Supply the flyback cured the problem of the flyback
Shuts down at turn on.set was not into xrp shutdown or any overcurrent condition. Traced
fault to an open 26 volt scan filter c4705 that allowed noise and ripple through which
CTC169 C4705 Power Supply affected the 9 and 12 volt run supplies Replace c4705

Intermittently the set would start at turn-on. Most of the time, the standby reg b+ would be
above 160v causing immediate shutdown. Ac would have to be removed in order for the
CTC169 CBA Power Supply power supply to restart. Found substance around r4104. Cleaned and unit worked Clean the board

Set would cycle on and off 3 times then quit. We found no b+ at the fault detect pin of
the micro. Tracing back we found no 9v being made at turn on. The 26v was not getting
CTC169 R4719 Power Supply to the collector of q4705. Lost it across r4719 . Replaced open r4719. 470 ohm. Replace r4719

Small picture. The set came to the shop originally with q4105 shorted in the error amp
circuit. After replacement, a lack of regulation was present with reg b+ running below
120v. Checking pin 2 of u4101 showed no control signal. At the collector of q4107, we
CTC169 CR4102 Power Supply had a horizontal rate squarewave but at only 5v p-p. The dc voltage read approx. 13v. Replace cr4102

Filament resistor r4703 runs red hot. Found t7002 on the ptv power supply overheated. Repaired open
Replacement t7002 overheats as well. Found pin 1 of t7002 not grounded. Found the ground and
ctc169pg T7002 Power Supply wires in connector j7020 to be not completely seated. replaced t7002.
Video flashes on and off. Convergence bouncing. U7004 pin 7 fluctuating between 14.5v
and 16v. Q7050 c was low and steady. All voltages on q7051 were jumping in time with
ctc169 r7194 Power Supply pin 7. Found that r7194 off of q7050 was at 250k. Replace r7194
CTC169bg no video , had video jumping out pip. Found the 12vd missing due to jc211 on the pip 12
5 JC211 Power Supply volt run. Resolder jc211, restored main picture and pip video. Resolder jc211,
No color. 9v line to u1001 at 7.5v. Traced back to q4705 only had 11.5v on collector.
ctc169 r4719 Power Supply Checked r4719 and found it to be about double in value. Replace r4719
Tv would shut down with an increase of beam current whether it was related to picture
CTC169JS Low Voltage content or an increase of the screen or brightness adjustments. With b+ reduced, it would
5 R4108 Power Supply not shut down. Measuring resistance to ground from u4101 pin 3, approx. 650 ohms. Replace r4108
Low Voltage
ctc169bg5 c4005 Power Supply Would blow fuse immediately on plug in. Found c4005 to be shorted. Replace c4005.