Job No Sheet No Dwg Ref Rev No

CC-431
Job Title 500L Water Tank at RF 123-127 Sai Yee St
Part of Structure
Client Prepared Date
Chk By 08-17-2016

Check Grade ISO 8.8 2.00 M6 3 Bolts and Nuts 1 for fixing panel along long edge

Reaction forces at panel support in per meter run


Tension, TB = DL-1.4WL = [0.49kN-1.4x(5.02kPax0.915m)x1.22m]/0.915m = 8.039 kN/m
Shear, V = 1.4 x 5.02kPa x 0.915m x 1.22m/2sides = 3.923 kN/m

Net Area at root of threaded size about M6 Bolts and Nuts


Anet = 20.1234 mm

Shear Stress = Force/Area


375 MPa = 3.92x10/ Areq
Areq = 10.46 mm

Tensile Stress = Force/Area


560 MPa = 8.04x10/ Areq
Areq = 14.35 mm

Quantities of M6 Bolts and Nuts


no of screw = Areq/Anet = 0.71 nos
say = 3.00 nos
Spacing
spacing = 1000mm/3nos
= 333.33 mm c/c
say = 300.00 mm c/c
Provide M6 Grade ISO 8.8-300mm c/c

Check M6 Grade ISO 8.8-300mm c/c


Shear capacity of M6 Bolts and Nuts, ps = 375.00 N/mm
Shear Area, At = 20.12 mm
Shear capacity, Pv = pvAc = 7.546 kN
> V = 3.923kN/m / 3nos = 1.308 kN OK

Check M6 Grade ISO 8.8-300mm c/c


Tension capacity of M6 Bolts and Nuts, pt = 560.00 N/mm
Tensile Area, At = 20.12 mm
Tension capacity, Pt = ptAc = 11.269 kN
> T = 8.039kN/m / 3nos = 2.680 kN OK