You are on page 1of 36

CONTENTS

Power Monitors DIN Rail Mount Voltage Monitors


SP100/SP103: Current Monitor, Single Phase 2 ZHRV3-01: Adjustable Phase Sequence/Failure/Asymmetry Monitor 16
SP101/SP104: Current Monitor, Single Phase 2 ZHRV3-07: 3Phase Voltage Monitor 16
SP120/SP123: Current Window Comparator, Single Phase 2 ZHRV5-01: Single Phase Voltage Window Comparator 16
SP121: DC Current Window Comparator 2 ZHRV5-02: Single Phase Over/Under Voltage Monitor 16
SP200/SP201: Voltage Monitor, Single Phase 3 ZHRV5-09: 3Phase Over/Under Voltage/Phase Sequence/Failure Asymmetry Monitor 16
SP220/SP221: Voltage Window Comparator, Single Phase 3 ZHRV5-11: Phase Sequence/Failure/Asymmetry Monitor
AP221: Voltage Window Comparator, Single Phase AC/DC 3
AP224: Combined Over-Voltage & Under-Voltage Monitor-2 Independent Relays 3
SP230/SP231/SP232: Voltage Window Comparator, Three Phase 4 Motor Power Monitor
AP231/AP232: Voltage Window Comparator, Three Phase 4
ZHRA1: Current Monitor Motor Protector 17
AP234/AP235: Combined Over-Voltage and Under-Voltage Monitor, Three Phase 4
ZHRA5: Self Powered Current Monitor Motor Protector 17
SP320: Frequency Monitor 4
SP430/SP431: Phase Sequence, Phase Failure, Phase Asymmetry Detector 5
5
Liquid Level Controller
AP430/AP432: Phase Sequence, Phase Failure, Phase Asymmetry Monitor
SP510: Single Phase Reverse Power Monitor 5 ZHRL1: DIN Rail Mount Liquid Level Controller 17
SX125/SX131: Phase Sequence, Phase Failure, Phase Asymmetry Detect with Alarm 5
Special Products
Electronic Timers CM193: 3Phase Current Monitor 18
ST100/ST101: Multi-Function Timer 6 DT310/12: Re-Cycling Timer with Pause 18
AT100: Multi-Function Timer 6 PSM1130/3: Control Module for Inductive Sensors 18
ST110/ST111/ST112/ST113: Electronic Reset Timer 6 SAS110: Semi-Automatic Synchronising Unit 18
AT110: Electronic Reset Timer 6 SP08M/SP08: Spark Detector Module and Optic 18
ST130: Star-Delta Timer 7
AT130: Star-Delta Timer 7 Digital Panel Meters
ST200/201/202/203: Unequal Cycling Timer 7 Digital Panel Meters (48 x 48mm & 72 x 72mm) 19
AT200: Asymmetrical Recycling Timer 7 Digital Process Meters 20
ST210: Multi-Function Asymmetrical Reset Timer 8 Digital Timers and Counters 20
ST300/301: No Power Delay Off Timer 8
ST410/411: AC Interval or Complementary Lamp Flasher 8
ST500: Multi-Start Attempt Unit 8 Industrial Relays & Bases
AT500: Multi-Start Attempt Unit 8 8 & 11 Pin Industrial Relays and Bases 21
48T100: Multi-Function Timer 9 8 & 11 Pin Plug in Timercube 21
48T101: Delay On/Interval (One Shot) Timer 9 8 & 14 Pin Industrial Relays and Bases 22

Process Controllers and Countaline Industrial Relays & Bases


SC100: Control Module for Resistive Sensor 10 Intelligent Can Line Sensor 23
SC130: Liquid Level Controller 10 Opto Electronic Sensors 23
AC130: Liquid Level Controller 10 Capacitive Sensors 24
SC230: Level Control Module for NAMUR Sensor 10 Namur Inductive Sensors 25
SC300: Control Module for NAMUR Sensor 11 Sensor Tester 25
SC301: Intrinsically Safe Control Module for NAMUR Sensor 11 AC Inductive Sensors 26
SC314: 3-Wire DC Sensor Interface Relay Module 11 DC Inductive Sensors 27
SC320: Tachometer Relay 11 50 x 50mm Photo-Electric Sensors-Diffuse and Retro-Reflex 28
SC410/SC411: Opto-Electronic Control unit 12 M18 Photo-Electric Sensors-Diffuse and Retro-Reflex 29
SC501: Temperature Control Module 12 50 x 50mm and M18 Photo-Electric Through Beam Sensors 30
SC510/SC511: Thermistor Motor Protection Module 12
SC610/SC611: Flip-Flop Relay with/without Memory 12
Accessories
SC900: Power Supply Module 13 Accessories for Sensors 31
CC120: Totalising Counter 13 Liquid Level Probe Kits 31
SC700: Multi-Function Preselect Counter 13 Siren Modules 31
CC701: Preselect Counter 13 PT1: Pressure Transmitter 31
Motor Protection Relays Process Gauges
MP820: Motor System Protection Relay Underload Reset Timer, Single Phase 14 Stainless Steel Case with Bezel 32
MP825: Motor System Protection Relay Variable Underload Monitor. Single Phase 14 Robust Liquid Filled 32
MP830: Motor System Protection Relay Underload Reset Timer, Three Phase 14 Economic Injection Moulded Case 32
MP835: Motor System Protection Relay Variable Underload Monitor, Three Phase 14 Process Gauge Accessories 32

DIN Rial Mount Timers/Voltage & Current Monitors Housing Dimensions & Technical Specifications
ZHRT1-A: Delay On Timer 15 Slimline/A-Line/48 x 48 Timers Dimensions 33
ZHRT1-M: Multi-Function Timer 15 Counterline/Industrial Relays Dimensions 33
ZHRT1-ST: Star Delta Timer 15 Specifications for Relays fitted into: Slimline, A-Line Counterline/Thermolne 34
ZHRT1-LS: Passage Light Timer 15
ZHRT1-S2: Unequal Cycling Timer 15

1 RHE
AFE
FAILSURES
FEAT POWER MONITORS
Current Monitor - Current Monitor - Current Window DC Current Window
Type Single Phase Single Phase Comparator - Single Phase Comparator

Code SP100/SP103 SP101/SP104 SP120/SP123 SP121


Features Internal shunt for direct in-line Internal shunt for direct in-line sensing Direct in-line current sensing Combined overload and under
current sensing (AC or DC) of currents up to 200mA (AC or DC) Combined overload and underload load detection
Adjustable responsible delay of 0.1 to Adjustable responsible delay of 0.1 to detection Internal shunt for direct in-line
10 seconds on SP103 10 seconds on SP104 Internal shunt for direct in-line current sensing of currents up to
1A or 5A, AC or DC input range Direct interface with DC Shunt sensing 200mA DC
(programmable) Resistors Adjustable responsible delay of 0.1 to Direct interface
Direct interface with conventional Trip point adjustable on calibrated 10 seconds on SP123 Separate adjustment of overload
scale 0-100% 1A or 5A AC input range and underload thresholds
current transformers.
(programmable) Latching in both modes
Trip point adjustable on percentage Hysteresis adjustable 5-30%
Direct interface with conventional
scale Programmable for overload or Range selector switch for 1mA,
current transformers
Hysteresis adjustable 5-30% underload detection. 20mA, 200mA, 60mV, 150mV,
Separate adjustment of overload and
Programmable for overload or Latching on overload or undeload threshold and 5V
underload detection. underload (programmable). Latching in both modes. LED indication for overload,
Latching on overload or underload Start-up delay LED indications for overload, underload and normal load
(programmable) 10A SPDT relay output underload and normal load. Start-up delay
Start-up delay Start-up delay 10A SPDT relay output
10A SPDT relay output 10A SPDT relay output

Connection
Diagram

DPDT on request (No Latching) DPDT on request (No Latching) DPDT on request (No Latching) DPDT on request (No Latching)

Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY


AC: Supply voltage: 12, 24, 115, 230, AC: Supply voltage:12, 24, 115, 230, AC: Supply voltage:12, 24, 115, 230, AC: Supply voltage: 12, 24, 115, 230,
400, 415, 525V 15% 400, 415, 525V 15% Isolation (current 400, 415, 525V 15% 400, 415, 525V 15%
Isolation (current input to power supply): input to power supply): 2kV Isolation (current input to power Isolation (current input to power
2kV Power consumption: 3VA (approx), supply): 2kV Power consumption: 3VA supply): 2kV
Power consumption: 3VA (approx), 6VA for 415, 525V (approx) (approx), 6VA for 415, 525V (approx) Power consumption: 3VA (approx),
6VA for 415, 525V (approx) DC: Supply voltage: 10-30V, 48, 60, DC: Supply voltage: 10-30V, 48, 60, 6VA for 415, 525V (approx)
110V 15% DC: Supply voltage: 12, 24, 48, 60,
DC: Supply voltage: 10-30V, 48, 60, 110V 110V 15%
Isolation: no galvanic isolation. 110V 15%
15% Isolation: no galvanic isolation.
Power consumption: 100mA (10-30V), Isolation: no galvanic isolation.
Isolation: No galvanic isolation. Power consumption: 100mA (10-30V), 30mA for 48V and higher Power consumption: 100mA (12, 24V),
Power consumption: 100mA 30mA for 48V and higher CURRENT INPUT 30mA for 48V and higher
(10-30V), 30mA for 48V and higher CURRENT INPUT Trip point: 0.1 to 1A or 0.5 to 5A AC CURRENT INPUT
CURRENT INPUT Repetitive accuracy: 1% (adjustable) Repetitive accuracy: 1%
Trip point: 0.1 to 1A or 0.5 to 5A AC/DC Hysteresis: 5% to 30% (adjustable) Repetitive accuracy: 1% Hysteresis: 2% Fixed
(adjustable) Input Max. Input Hysteresis: 2% Fixed (relative to sensitivity setting)
Repetitive accuracy: 1% Range (relative to trip point setting)
Impedance (Continuous) Input Max. Input
Hysteresis: 5% to 30% (adjustable) 1mA 60 Ohm 60mA Maximum input current (continuous): Range Impedance (Continuous)
Maximum input current 20mA 3 Ohm 350mA 6A 1mA 60 Ohm 60mA
200mA 0.7 Ohm 800mA 20mA 3 Ohm 350mA
(continuous): 6A 60mV 10k 50V Peak short-term over-current (10
200mA 0.7 Ohm 800mA
Peak short-term over-current 150mV 10k 50V seconds): 20A 60mV 10k 50V
(10 seconds): 20A 5mV 10k 50V Current input impedance: 50 milliohms 150mV 10k 50V
Current input impedance: 50 milliohms. RESPONSE RESPONSE 5mV 10k 50V
RESPONSE Start-up delay: approximately 10 Start-up delay: approximately 10 RESPONSE
Start-up delay: Approximately 10 seconds, standard. (1 to 15 seconds also seconds, standard (1 to 15 seconds Start-up delay: approximately 10
seconds, standard. (0.1 to 15 seconds possible on special order) Response also possible on special order) seconds, standard (1 to 15 seconds
Response delay: SP120 - 1 second. also possible on special order)
also possible on special order) Response delay: SP101 - 1 second. SP104 -
*Relay Contacts: SP123 - adjustable from 1 to 10 Response delay: SP121 - 1 second
Delay: SP100 - 1 second, SP103 - adjustable from 0.1 to 10 seconds (other
SP = Single Pole seconds (other ranges on special
adjustable from 0.1 to 10 seconds (other ranges on special order)
DP = Double Pole order)
ranges on special order)
Ordering Code TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
Example SP 100 230V AC
*
SP SP 101 230V AC
* SP 120 230V AC
* SP 121 230V AC
*

RHE
RHE 2
AFE
FAILSURES
FEAT POWER MONITORS
Voltage Monitor - Voltage Window Comparator - Voltage Window Comparator Combined Over/Under Voltage
Type
Single Phase Single Phase - Single Phase AC/DC Monitor, 2 Independent Relays

Code SP200/SP201 SP220/SP221 AP221 AP224


Features Programmable input voltage range Combined over-voltage and DIN rail format DIN rail format
0 to 600V AC(RMS) or DC under-voltage detection Combined over-voltage and Combined over and under
Adjustable response delay from 0.1 Adjustable response delay of 0.1 under-voltage monitoring detection voltage
to 10 seconds on SP201 to 10 seconds on SP221 Monitoring of own supply voltage Internal shunt for direct in-line
Voltage threshold adjustable on Monitoring of own supply voltage Selectable power supply voltages sensing of currents up to
calibrated scale, 0-100% High precision and repetitive High precision and repetitive accuracy 200mA DC
Adjustable hysteresis 5-30% accuracy Independent adjustment of Direct interface
Programmable for over-voltage or Independent setting of over- over-voltage and under-voltage Separate relay for over-voltage
under-voltage detection voltage and under-voltage tripping setpoints and under-voltage
Latching on over-voltage or under- points Adjustable response times Separate adjustment of
voltage LED indication for type of fault available on trip and/or recovery overload and underload
10A SPDT relay output and status of the relay (0.1-10 secs) thresholds
Latching facility Adjustable start-up delay (0-10 secs) Latching in both modes
10A SPDT relay output Latching on over-voltage or under- Range selector switch for 1mA,
voltage fault conditions 20mA, 200mA, 60mV, 150mV,
(programmable) and 5V
LED indication for Relay ON, over- LED indication for overload,
voltage & undervoltage underload and normal load
Start-up delay
5A DPDT relay output
5A DPDT relay output
Connection Voltage Input
AC or DC
6
5 7
Diagram
4 8
6
5 7
3 9 Under volts Over volts
4 8

3 9 2 10
2 10 1 11
1 11

~ AC ~ AC or DC
Power Supply Power Supply
DPDT on request (No Latching) DPDT on request (No Latching) DPDT only SPDT only (2x single pole relay)

Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY


AC: Supply voltage: 12, 24, 115, 230, AC: Supply voltage: 12, 24, 115, 230, AC: 12, 24, 115, 230, 400, 525V AC AC: Supply voltage: 12, 24, 115, 400,
400, 415, 525V 15% 400, 415, 525V 20% Isolation: Galvanic (without latching) 525V AC
Isolation (current input to power Isolation (current input to power Power consumption: 2VA (approx) Isolation: Galvanic (without latching)
supply): 2kV supply): 2kV Housing width: 45mm Power consumption: 2VA (approx)
Power consumption: 3VA (approx), Power consumption: 3VA (approx), Voltage tolerance: 20% Housing width: 45mm
6VA for 415, 525V (approx) 6VA for 415, 525V (approx) DC: Supply voltage: 12, 24, 48, 60, Voltage tolerance: 20%
DC: Supply voltage: 10-30V, 48, 60, DC: Supply voltage: 12, 24, 48, 60, 110V DC DC: Supply voltage: 12, 24, 48, 60,
110V 15% 110V 20% Isolation: No galvanic isolation 110V DC
Isolation: No galvanic isolation Isolation: no galvanic isolation Power consumption: 30mA (approx) Isolation: No galvanic isolation
Power consumption: 100mA Power consumption: 100mA (12, 24V), Housing width: 45mm Power consumption: 30mA (approx)
(10-30V), 30mA for 48V and higher 30mA for 48V and higher Voltage tolerance: 20% Housing width: 45mm
VOLTAGE INPUT VOLTAGE SENSING VOLTAGE SENSING Voltage tolerance: 20%
Repetative accuracy: 1% Calibrated to respond to RMS of a Repetitive accuracy: 1% VOLTAGE SENSING
Hysteresis: 5% to 30% (adjustable) sinusoidal waveform Hysteresis: 2% fixed Repetitive accuracy: 1%
Repetitive accuracy: 1% Hysteresis relates to the supply Hysteresis: 2% (fixed)
Input Max. Input
Range Hysteresis: 2% fixed (relative to its voltage Setpoints: The unit is calibrated to
Impedance Voltage
0-15V 500k Ohm 700V supply voltage) Setpoints: The unit is calibrated to trip on the RMS value of the supply
0-30V 500k Ohm 700V Response dealy: SP220 - 1 second trip on the RMS value of the supply voltage (assuming no AC waveform
0-60V 500k Ohm 700V
0-150V 500k Ohm 700V SP221 - adjustable from 0.1 to 10 voltage (assuming no AC waveform distortion)
0-300V 500k Ohm 700V seconds (other ranges on special distortion) RESPONSE
0-600V 500k Ohm 700V order) RESPONSE Response time on trip:
RESPONSE Latching disabled during power-up: Response time on trip: 0,1 - 10 seconds (adjustable)
Response delay: SP200 - 1 second approx. 10 seconds 0.1 - 10 seconds (adjustable) Response time on recovery:
SP201 - adjustable from 0.1 to 10 sec- Response time on recovery: 0,1 - 10 seconds (adjustable)
onds (other ranges on special order) 0.1 - 10 seconds (adjustable) Start-up delay: 0 - 10 seconds
*Relay Contacts: Latching disabled during Start-up delay: (adjustable)
SP = Single Pole power-up: approx. 10 seconds 0 - 10 seconds (adjustable) Latching inhibited during power up
DP = Double Pole Latching inhibited during power up
Ordering Code TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS

Example SP 200 230V AC * SP 220 230V AC * AP 221 230V AC DP AP 224 230V AC SP

3 RHE
AFE
FAILSURES
FEAT POWER MONITORS
Type Voltage Window Comparator - Voltage Window Comparator - Combined Over/Under-
Frequency Monitor
Three Phase Three Phase Voltage Monitor, Three Phase

Code SP230/SP231/SP232 AP231/AP232 AP234/AP235 SP320


Features Combined over-voltage and Combined over-voltage and under DIN rail format Monitoring frequency of own
under-voltage detection voltage monitoring Combined over-voltage and under- power supply
Monitoring of own supply voltage Monitoring of own supply voltages voltage monitoring High precision and repetitive
Adjustable response delay on AP232 available with neutral Separate relays for over-voltage accuracy
SP231 Selectable power supply voltages and under-voltage Independent setting of over
SP232 available with neutral High precision and repetitive accuracy Monitoring of own supply voltage and under-frequency tripping
High precision and repetitive Independent adjustment of over- AP235 Available with neutral point
accuracy voltage and under-voltage setpoints Selectable power supply voltages LED indication of type of fault
Independent setting of over- Separately adjustable response times High precision and repetitive and relay status
voltage tripping points on trip and recovery (0.1 to 10 secs.) accuracy Programmable for over-
LED indication for type of fault Adjustable start-up delay (0-10 Independent adjustment of over frequency, under-frequency or
and status of the relay seconds) voltage and under-voltage setpoints frequency window detection
Latching facility Latching of fault conditions (prog.) Adjustable response times - Start-up delay
10A SPDT relay output Microprocessor technology available on trip and/or recovery 10A SPDT relay output
incorporated (0.1 to 10 seconds)
LED indication for type of fault and LED indication of over-voltage
relay status relay on and under-voltage relay
5A DPDT relay as standard on (power LED flashes when timing)
DIN rail mounting 8A SPDT over-voltage relay output

Connection Link for start-up delay

Diagram

SP-230/231 AP-231 AP-234


SP-232 AP-232 AP-235
DPDT on request (No Latching) DPDT only SPDT only (2x single pole relay) DPDT on request

Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY


Supply voltage (phase-to-phase): 115, Supply type: AC transformer supply only Supply type: AC transformer supply Supply voltage: 12, 24, 115, 230,
230, 400, 415, 525V AC 15% Supply voltage: 115, 230, 400, 525V only 400, 415, 525V, AC 15%
Power consumption: 3VA (approx), 6VA Housing width: 45mm Supply voltage: 115, 230, 400, 525V Power consumption: 3VA
for 415, 525V AC (approx) Power consumption: 2VA (approx) AC (approx), 6VA for 415, 525V
VOLTAGE SENSING Isolation: Galvanic Housing width: 45mm (approx)
Calibrated to respond to the RMS of a Voltage tolerance: 20% Power consumption: 2VA (approx) Supply frequency: 42Hz - 58Hz
sinusoidal waveform. VOLTAGE SENSING Isolation: Galvanic (60Hz available on special order)
Repetitive accuracy: 1% Setpoints: The unit is calibrated to trip (without latching) RESPONSE
Hysteresis: 2% fixed on the RMS value of the supply voltage Voltage tolerance: 20% Start-up delay: Approximately 10
(relative to its supply voltage) (assuming no AC waveform distortion) VOLTAGE SENSING seconds standard
Response delay: 1 second Repetitive accuracy: 1% Setpoints: The unit is calibrated to (1 to 15 seconds available on
Latching disabled during power-up: Hysteresis: 2% (fixed) trip on the RMS value of the supply special order)
approx. 10 seconds - SP231 Only Hysteresis relates to the supply voltage voltage (assuming no AC waveform Response delay: 1 second
RESPONSE distortion) FREQUENCY SENSING
Response time on trip: 0.1 - 10 seconds Repetitive accuracy: 1% Repetitive accuracy: 1%
(adjustable) Hysteresis: 2% (fixed) Hysteresis: 0.5 Hz fixed
Response time on recovery: 0.1 - 10 Hysteresis relates to the supply
seconds (adjustable) voltage
Start-up delay: 0 - 10 seconds RESPONSE
Latching inhibited during power up Response time on trip: 0.1 - 10
seconds (adjustable)
Response time on recovery: 0.1 - 10
seconds (adjustable)
Start-up delay: 0 - 10 seconds
*Relay Contacts: (adjustable)
SP = Single Pole Latching inhibited during power up
DP = Double Pole
Ordering Code TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS

Example SP 230 230V AC AP


* AP 231 230V AC DP 234 230V AC SP SP 320 230V AC
*

RHE
RHE 4
AFE
FAILSURES
FEAT POWER MONITORS
Phase Sequence, Phase Failure, Phase Sequence, Phase Failure, Single Phase, Reverse Power Phase Sequence, Phase Failure, Phase
Type Phase Asymmetry Detector Phase Assymetry Monitor Monitor (Generator Protection) Asymmetry Detector with Alarm

Code SP430/SP431 AP430/AP432 SP510 SX125/SX131


Features Detection of phase asymmetry DIN rail mount Reverse current tripping level Detection of phase asymmetry
Adjustable sensitivity Detection of phase asymmetry adjustable up to 20% of Clear warning alarm when
Insensitive to regenerated EMF Adjustable Negative Phase maximum forward current detection has taken place
High stability under harmonic Sequence (NPS) sensitivity Current monitoring through (SX125)
distortion Insensitive to regenerated EMF internal shunt 5mm bright LED indication with
Insensitive to balanced supply High stability under harmonic Response time adjustable up detection (SX125 & SX131)
voltage variations distortion to 10 seconds Insensitive to regenerated EMF
Fast response to reversed Insensitive to balance supply Start-up delay adjustable up High stability under harmonic
phase sequence voltage variations to 10 seconds distortion
SP431 available with neutral Fast response to reversed phase Insensitive to changes in Insensitive to balanced supply
10A SPDT Relay output sequence power factor voltage variations
AP432 Available with neutral LED indication for reverse Fast response to reversed phase
Power ON and Relay ON LEDs power and Relay ON sequence
Latching facility 10A DPDT Relay Output
10A SPDT Relay output

Connection
Diagram

SP-430 SP-430
SP-431 SP-432

DPDT on request SPDT On Request DPDT On Request (No Latching) DPDT Only
Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY
Supply voltage (phase-to-phase): Type: AC transformer Supply voltage: 115, 230, 400, 415, Supply voltage (phase-to-phase):
115, 230, 400, 525V AC 20% (2kV galvanic isolation) 525V AC 15% 115, 230, 400, 525V AC 20%
Power consumption: 3VA Voltage: 115, 230, 400, 525, 550V Power consumption: 3VA Power consumption: 3VA
(approx), 6VA for 415, 525V AC Tolerance: 20% (approx), 6VA for 415, 525V AC (approx), 6VA for 415, 525V AC
(approx) Power consumption: 2VA (approx) (approx) (approx)
VOLTAGE SENSING HOUSING CURRENT INPUT VOLTAGE SENSING
Repetitive accuracy: 1% 250V and below: 22.5mm width Input current range: 0 - 5A AC Repetitive accuracy: 1%
Hysteresis: 2% fixed Above 250V: 45mm width Reverse current sensitivity: Hysteresis: 2% fixed (relative to its
(relative to its supply voltage) VOLTAGE SENSING 100mA to 1A AC (adjustable) supply voltage)
Response delay: 1 second Repetitive accuracy: 1% Repetitive accuracy: 1% Response delay: 1 second
(approx) Hysteresis: 2% (fixed) Hysteresis: 5% (fixed) (approx)
Hysteresis relates to the supply Maximum input current
voltage (continuous): 6A
Response delay: 1 second (approx) Peak short term over current
RELAY (10 seconds): 20A
Relay options (250V): 10A SPDT Current input impendance:
or 5A DPDT 50 milliohms
RESPONSE
Start-up delay: 0 - 10 seconds
(adjustable)
Response delay: 1 - 10 seconds
(adjustable)

*Relay contact
SP= Single Pole
DP= Double Pole

Ordering Code TYPE MODEL VOLTAGE POWER


SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY

Example SP 430 230V AC


* AP 430 230V AC
* SP 510 230V AC
* SX 125 230V AC

5 RHE
RHE
AFE
FAILSURES
FEAT
ELECTRONIC TIMERS
Type Multi-Function Timer Multi-Function Timer Electronic Reset Timer Electronic Reset Timer

Code ST100/ST101 AT100 ST110/ST111/ST112/ST113 AT110


Features Programmable functions: 4 programmable functions: Programmable functions: Delayed Programmable functions: Delayed ON,
Delayed ON, Interval (one shot), Delayed ON, Interval (one shot) or ON, Interval (one shot), both with Interval (one shot), both with hold or pulse
Equal Repeating Equal Repeating (OFF/ON first) hold or pulse reset reset
Programmable functions and 18 overlapping programmable Programmable in six independent 18 overlapping programmable time ranges
independent overlapping time time ranges from 0,2 seconds to overlapping time ranges from 0,2 seconds to 100 hours, achieved by:
ranges 100 hours, achieved by: Direct interface with DC three-wire 3 programmable time ranges:
Extended supply voltage range: 3 programmable time ranges: NPN (ST110/ST111) and PNP seconds, minutes, hours
10V to 30V AC/DC, 90V to 250V AC seconds, minutes, hours (ST112/ST113) sensors 6 programmable time scales for
Specific power supply voltage High speed electronic reset & each of 3 time ranges
6 programmable time scales
available on request repetitive accuracy Time Setting on calibrated scale(10 -100%)
for each of 3 time ranges
Time adjustment on calibrated Time adjustment on calibrated High speed electronic reset and high
scale: 0 - 100% Time Settings on calibrated scale scale, 0-100% repetitive accuracy
High repetitive accuracy (10% - 100%) 5A double pole relay output (10A Direct interface with DC three-wire
5A DPDT relay output High repetitive accuracy SPDT offered on request) NPN/PNP sensors, with reset inputs
Time range: ST100: Up to 120 sec. Microprocessor technology Time Ranges: for either PNP or NPN in the same unit
ST101: Up to 240 min Power ON and Relay ON LEDs ST110/ST112: Up to 120 sec Power ON, Relay ON and reset LEDs
Extended time ranges available up Flashing Power ON LED when unit ST111/ST113: Up to 240 min Flashing Power ON LED when unit is timing
to 25 hours or 200 hours on special is timing Extended time ranges available up Microprocessor technology incorporated
order 5A SPDT or DPDT relay output to 200 hours on special orders 5A SPDT or DPDT relay output
Connection
Diagram

SPDT SPDT SPDT SPDT


DPDT DPDT DPDT DPDT

Instantaneous Contacts & External Pot available

Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY


AC: Supply voltage: AC: Supply voltage: 12, 24, 115, 230, AC: Supply voltage: 12, 24, 115, 230, AC: Supply voltage: 12, 24, 115, 230,
Not galvanic: 230VAC = 90 - 250VAC 400, 525V 400, 415, 525V 15%. Isolation (reset 400, 525V
Galvanic: 12, 24, 115, 230, 400, 415, Power Consumption: 2VA (approx) input to power supply): 2kV 2kV Galvanic isolation
525V 15% Tolerance: 15% Power consumption: 3VA (approx), Power Consumption: 2VA (approx)
Power consumption: 3VA (approx), 6VA for 415, 525V (approx) Tolerance: 15%
AC Reactive: Supply Voltage: DC: Supply Voltage: 48, 60, 110V
6VA for 415, 525V (approx) DC: Supply voltage: 10-30V, 48, 60,
230VAC = 90-250VAC 110V 15% Isolation: no galvanic Power Consumption: 30mA (approx)
DC: Supply voltage: 48, 60, 110V 15% Power consumption: 2VA (approx) Tolerance: 15%
Power consumption: 30mA isolation. Power consumption: 100mA
DC: Supply Voltage: 48, 60, 110V (10-30V), 30mA for higher ranges AC/DC: Supply Voltage: 12/24V
AC/DC: Supply voltage: 10 - 30V Power Consumption: 30mA (appro.) Power Consumption: 100mA (approx)
Power consumption: 100mA RESET INPUT
Tolerance: 15% Reset time: 2 milliseconds Tolerance: 15%
Reset: Power supply to be interrupted RESET INPUT
AC/DC: Supply Voltage: 12/24V Short circuit current: 1mA
for at least 0,5 seconds. For high speed Input type: NPN Sensor, PNP
Power Consumption: 100mA (approx) Open circuit voltage: 8.2V
reset applications, refer to ST110 Sensor, Potential free contact
Tolerance: 15% 12V DC OUTPUT: Minimum Pulse width: 4mS
ST-100 TIME SPECIFICATION Voltage tolerance: 10-15V DC Open circuit Voltage: <5, 6V
Switch S1 Time Ranges
Setting Accuracy: 5% Source current: 30mA (max.) HOUSING
1,8s - Up to 1,8s ST-110/112 250V and below: 22,5mm width
7,5s - Up to 7,5s Repeatability: 0.5%
15s - Up to 15s HOUSING Switch S1 Time Ranges Above 250V: 45mm width
**L = Extended 30s - Up to 30s 1,8s - Up to 1,8s RELAY
250V and below: 22,5mm width. 7,5s - Up to 7,5s
Time Range 60s - Up to 60s Relay Options: (250, 5A)SPDT or DPDT
120s - Up to 120s Above 250V: 45mm width 15s - Up to 15s
DC OUTPUT
**E = External Pot RELAY 30s - Up to 30s
ST-101 60s - Up to 60s Voltage tolerance: 10-24V
**I = Instantaneous Relay Options (250V, 5A)SPDT, DPDT 120s - Up to 120s Source Current: 10mA
Switch S1 Time Ranges
Contacts 220s - Up to 220s TIME RANGES (STANDARD) ST-111/113 Setting Accuracy: 5%
**TX = Galvanic 7,5m - Up to 7,5m 2: 0.2 to 2 sec, min or hrs 220s - Up to 220s Repeatability: 0,5%
15m - Up to 15m 5: 0.5 to 5 sec, min or hrs 7,5m - Up to 7,5m TIME RANGES (STANDARD)
60m - Up to 60m
10: 1 to 10 sec, min or hrs
15m - Up to 15m 2: 0,2 to 2 sec, min or hrs
120m - Up to 120m 60m - Up to 60m 5: 0,5 to 5 sec, min or hrs
*Relay contact 240m - Up to 240m 20: 2 to 20 sec, min or hrs 120m - Up to 120m 10: 1 to 10 sec, min or hrs
50: 5 to 50 sec, min or hrs 240m - Up to 240m
SP= Single Pole Extended time range available on Extended time ranges on special order:
20: 2 to 20 sec, min or hrs
DP= Double Pole special order: 6, 12, 5, 25, 50, 100, 100: 10 to 100 sec, min or hrs 50: 5 to 50 sec, min or hrs
6, 12, 5 and 25 hours
and 200 hours 50, 100, and 200 hours 100: 10 to 100 sec, min or hrs

Ordering Code
TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY
SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY CONTACTS

Example ST 100 230V AC


** * AT 100 230V AC
* ST 110 230V AC ** * AT 110 230V AC
*

RHE
RHE 6
AAFFEE
FFAAILILSSUURREESS
FF EA
E ATT ELECTRONIC TIMERS
Star-Delta Timer Star-Delta Timer Unequal Cycling Timer Unequal Cycling Timer
Type

Features
Code ST130 AT130 ST200/ST201/ST202/ST203 AT200
Features Relay de-energises to centre-off Relay de-energises to centre-off Programmable OFF-cycle first or Programmable for either OFF-cycle
position for failsafe operation position for failsafe operation ON-cycle first first or ON-cycle first
Adjustable time range of 0-60 Adjustable Star Time range of up to Programmable in 6 overlapping 12 overlapping programmble time
seconds 60 seconds time ranges ranges from 0,2 seconds to 4 hours
Incorporates 75 millisecond pause Fixed 75/50 millisecond pause Extended time ranges available up High repetitive accuracy
time to prevent overlapping of Star time to prevent overlapping of Star to 25 hours or 200 hours on special Power ON and Relay ON LEDs
and Delta switching and Delta switching order Flashing Power ON LED when unit is
LED indication of relay output LED indication of relay output Separate off/on time adjustment on timing (flash rate increases when
status, i.e.: Star or Delta mode status i.e. Star or Delta mode calibrated scale, 0-100% relay is about to switch)
Two relay method for interlocking Two SPDT relays with neutral High repetitive accuracy Microprocessor technology
of contacts ensuring break before centre position ensure break before 5A DPDT relay output (10A SPDT incorporated
make make offered on request) 5A SPDT or DPDT relay output.
5A relay output Microprocessor technology Timer T1 T2 Separate OFF/ON time range
Rated for continuous operation incorporated ST200 A A selection and time adjustments on
5A SPDT relay output ST201 A B calibrated scales, 0-100%
Rated for continuous operation ST202 B B Link Y1/Y2 to Y3 for minutes
ST203 B A Link Y3 to Y4 for On first

Connection
Diagram

SPDT SPDT
DPDT DPDT
AC or DC
Power Supply 2x External Pot available, Pins 5, 6, 7
External Pot available, Pins 5, 6, 7 (Off cycle first only)

Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY


AC: Supply voltage: 48, 60, 115, AC Transformer: Supply Voltage: AC: Supply voltage: AC: Supply voltage: 12, 24, 115, 230,
230, 400, 415, 525V 15% 12, 24, 115, 230, 400, 525V 15% 230, 400, 415, 525V 15% 400, 525V
Power consumption: 3VA (approx), 2kV galvanic isolation AC Reactive: Supply voltage: 2kV Galvanic isolation
6VA for 415, 525V (approx) Power consumption: 2VA, 6VA 230V (90-250V) Power Consumption: 2VA, 6VA (approx)
AC Reactive: Supply voltage: (approx) Power consumption: Tolerance: 15%
230V (90-250V) AC Reactive: Supply voltage: 3VA, 6VA for 415, 525V (approx) AC Reactive: Supply voltage:
DC: Supply voltage: 10-30V 230V (90-250V) DC: Supply voltage: 230V (90-250V)
Power consumption: 100mA 48, 60, 110V DC 15% Power Consumption: 100mA
AC/DC, 48, 60, 110V DC 10%
DC: Supply voltage: 48, 60, 110V Power consumption: 30mA
Isolation: no galvanic isolation DC: Supply Voltage: 48, 60, 110V
Power Consumption: 30mA 15% AC/DC: Supply voltage: 10-30V
Power consumption: 100mA for Power consumption: 30mA
AC/DC: Supply voltage: 12/24V AC/DC. Power consumption: 100mA
10-30V AC/DC, 30mA for higher Power consumption; 100mA 15% Tolerance: 15%
RESET
ranges HOUSING AC/DC: Supply voltage: 12/24V
Power supply to be interrupted for at
RESET 250V and below: 22,5mm width least 0,5 seconds Power consumption: 100mA
Power supply to be interrupted for Above 250V: 45mm width Extended time ranges available on Tolerance: 15%
at least 1 second RELAY: special order: 6, 12.5, 25, 50, 100 HOUSING
TIME SETTINGS Relay Options (250V, 5A): SPDT and 200 hours 250V and below: 22.5mm width
**L = Extended 0 - 60 seconds adjustable (1x SPST for Delta and 1x SPST A Above: 45mm width
Time Range PAUSE TIMER for Star) Switch Position Time Ranges RELAY
**E = External Pot Approximately 75 milliseconds RESET 1 - Up to 1,8s Relay options (250V, 5A): SPDT, DPDT
10% Power supply to be interrupted for at 2 - Up to 7,5s TIME SPECIFICATION
**I = Instantaneous 3 - Up to 15s Setting
least 1 second 4 - Up to 30s
Contacts PAUSE TIME 5 - Up to 60s Accuracy 5% Repeatability 0.5%
6 - Up to 120s TIME RANGES (STANDARD)
**TX = Galvanic 75 milliseconds B
STAR TIME ADJUSTMENT 2: 0,2 to 2 sec or min
7 - Up to 220s
SPDT FUNCTION 8 - Up to 7,5m 6: 0,6 to 6 sec or min
S1 60s Delay / 75ms Pause 9 - Up to 15m 20: 2 to 20 sec or min
*Relay contact S2 30s Delay / 75ms Pause 10 - Up to 60m 60: 6 to 60 sec or min
SP= Single Pole S3 60s Delay / 50ms Pause 11 - Up to 120m 120: 12 to 120 sec or min
DP= Double Pole S4 30s Delay / 50ms Pause 12 - Up to 240m
240: 24 to 240 sec or min

Ordering Code TYPE MODEL VOLTAGE POWER


SUPPLY
TYPE MODEL VOLTAGE POWER
SUPPLY
STAR
TIME
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS

Example ST 130 230V AC AT 130 230V AC S1 ST 200 230V AC


** * AT 200 230V AC
*

7 RHE
RHE
ELECTRONIC TIMERS
Multi-function Asym-met- No Power Delay AC Interval or Comple-
Type Multi-Start Attempt Unit Multi-Start Attempt Unit
rical Reset Timer OFF Timer mentary Lamp Flasher
AFE
FAILSURES
FEAT

Code ST210 ST300/ST301 ST410/ST411 ST500 AT500


6 Programmable reset functions Internal NiCd battery back-up Programmable: continuous Programmable number of Programmable number of start
Features starts: 3 to 8
with hold or pulse reset or on ST301 flashing or interval flashing attempts: 3 to 8
both, and power supply on reset Programmable in 6 independent Adjustable interval 1-10 secs Adjustable cranking time: Start failure alarm output
Programmable in 6 independent overlapping time ranges Pulse rate of 90 flashes per 1 to 10 seconds Separately adjustable starter
overlapping time ranges up to Time adjustment on calibrated minute as standard (other rated Start failure alarm output and pause times
120 seconds scale, 0-100% on special order) Adjustable starter time:
Direct interface with DC three- High repetitive accuracy Solid state switching 1 to 20 seconds
wire NPN sensor 10A single pole or 5A double Switching capacity 4A, 1000W Adjustable pause time:
High speed electronic reset pole relay output / 250V 1 to 20 seconds
High repetitive accuracy Time ranges: Power supply range Power On, Start Relay and
Time adjustment on calibrated ST300: up to 120 sec 90V-250VAC Alarm Relay LEDs
scale, 0-100% ST301: up to 240 min Two wire in-line connection Microprocessor technology
5A double pole relay output (ST410) or three wire in-line incorporated
(10A SPDT offered on request) connection (ST411) 5A SPDT Start Relay
5A SPDT Alarm Relay
(start failure)

Connection
Diagram

SPDT SPDT
DPDT DPDT

AC or DC AC or DC ST410 AC or DC
Power Supply Power Supply ST411 Power Supply

Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY
AC: Supply voltage: 12, 24, 115, AC: Supply voltage: 12, 24, 115, Supply voltage: 230 (90-250V) AC: Supply voltage: 48, 60, 115, AC: Supply Voltage: 12, 24, 115,
230, 400, 415, 525V 10% 230, 400, 415, 525V 15% Supply frequency: 45-70Hz 230V 15% 230, 400, 525V
Isolation (reset to power supply): Power consumption: 3VA, Minimum load: 15W (250VAC), Power consumption: 3VA (approx) 2kV galvanic isolation
2kV 6VA for 415, 525V (approx) 10W(110VAC) DC: Supply voltage: 48, 60, 110V Power Consumption: 2VA
Power consumption: 3VA, 6VA for DC: Supply voltage: 48, 60, Maximum load: 1000W 15% (approx)
400, 415, 525V (approx) 110V 15% (250VAC), 400W (110VAC) Power consumption: 30mA Tolerance: 15%
DC: Supply voltage: 10-30V Power consumption: 30mA Maximum load current: AC/DC: Supply voltage: AC Reactive: Supply voltage:
48, 60, 110V DC 15% AC/DC: Supply voltage: 12V 4A continuous 230 (90-250V)
10-30V AC/DC
Isolation: no galvanic isolation Power Consumption: 2VA
AC/DC and 24V AC/DC TIMING Power consumption: 100mA
Power consumption: DC: Supply Voltage: 48, 60, 110V
100mA (10-30V), 30mA for
Power consumption: 100mA Flash rate: 90 flashes per minute RESET
(standard). Optional pulse rates Power supply to be Power consumption: 30mA
higher ranges Tolerance: 15%
RESET INPUT available on special order interrupted for at least
Interval: 1-10 seconds 0,5 seconds AC/DC: Supply voltage: 12/24V
Reset time: 6ms
(adjustable) NUMBER OF START Power consumption: 100mA
Short circuit current: 2mA ST-300
Open circuit voltage: 8,2V RESET 3 to 8 (programmable) Tolerance: 15%
Switch S1 Time Ranges HOUSING
12V DC Output: Voltage 1,8s - Up to 1,8s Power supply to be interrupted DURATION OF START ATTEMPT
tolerance 10-15V DC 7,5s - Up to 7,5s for at least 5 seconds Adjustable from 1 to 10 seconds 250V and below: 22.5mm width
Source current: 30mA (max) 15s - Up to 15s DURATION OF PAUSE Above 250V: 45mm width
30s - Up to 30s
Equal to set duration of start ALARM RELAY
60s - Up to 60s
120s - Up to 120s attempt Contact rating 250V, 5A SPDT
ST301
STARTER RELAY
220s - Up to 220s Contact rating 250V, 5A SPDT
Switch Time Ranges - Up to 7,5m START ATTEMPTS
Position 7,5m
15m - Up to 15m Number of Start Attempts: 3 to 8
1 - Up to 1,8s 60m - Up to 60m
2 - Up to 7,5s 120m - Up to 120m Duration of Start Attempts:
240m - Up to 240m Adjustable from 1 to 20 secs
*Relay contact 3 - Up to 15s
4 - Up to 30s Duration of Pause between Start
SP= Single Pole **I = Instantaneous Contacts
5 - Up to 60s Attempts: Adjustable from 1 to 20
DP= Double Pole 6 - Up to 120s secs
Ordering Code TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER TYPE MODEL VOLTAGE POWER TYPE MODEL VOLTAGE POWER RELAY

Example
SUPPLY CONTACTS SUPPLY CONTACTS SUPPLY SUPPLY SUPPLY CONTACTS

ST 210 230V AC
* ST 300 230V AC
** * ST 410 250V AC ST 500 230V AC AT 500 230V AC SP

RHE 8
ELECTRONIC TIMERS
Delayed ON / Interval
Type Multi-Function Timer
(One Shot) Timer

Code 48T100 48T101


Features Microprocessor based Microprocessor based
Power On LED indication Power On LED indication
Relay operation LED indication Relay operation LED indication
Programmable functions: Time Range 0.1s to 100hrs
Delay on (Pulse start); Interval (Hold/ DPDT relay (5A) as standard
Pulse Start); Equal Flashing Power LED when timing
Repeating (On/Off First); Signal On/ 5 Sec Test Mode to confirm circuit
Off Delay operation and assist
Start - Reset - Gate Inputs commissioning
Gate Input: When activated the unit Front dial doubles as screwdriver
A-LINE & PUMP MONITOR
stops timing and continues when for adjusting controls PROTECTION HOUSING
released
Time Range 0.1s to 100hrs
DPDT relay (5A) as standard
Flashing Power LED when timing
5 Sec Test Mode to confirm circuit
operation and assist commissioning
Front dial doubles as screwdriver for
adjusting controls

Connection
Diagram 4 5
3 6
2 7
1 8
~ ~
- +
Power Supply

Available in 8 or 11 Pin Format

Specifications Power Supply: Power Supply:


AC Reactive: AC Reactive:
Supply Voltage: 230 (100-230VAC) Supply Voltage: 230(100-230VAC)
Power Consumption: 3VA Power Consumption: 3VA
AC/DC: AC/DC:
Supply Voltage: 24(24VAC/DC) Supply Voltage: 24(24VAC/DC)
DC: DC:
Supply Voltage: 12VDC Supply Voltage: 12VDC
Power Consumption: 1.5W Power Consumption: 1.5W
Tolerance: 10% Tolerance: 10%
Reset Times Reset Times
Input Reset: 50msec min Input Reset: 50msec min
Power Reset: 100msec min Power Reset: 100msec min
Timing Settings Timing Settings
Scale Multiplier Scale Multiplier
Range Range
X1 X10 X1 X10
Sec 0.1- 1sec 1 - 10sec Sec 0.1- 1sec 1 - 10sec
Min 0.1 - 1min 1 - 10 min Min 0.1 - 1min 1 - 10 min
Hrs 0.1 - 1hrs 1 - 10 hrs Hrs 0.1 - 1hrs 1 - 10 hrs
10Hrst 1 - 10hrs 10 - 100hrs 10Hrst 1 - 10hrs 10 - 100hrs
Clips for Slimline
General Specifications: General Specifications: consists of 10 sets
Enclosure protection rating: IP40 Enclosure protection rating: IP40
Size: 48 x 48 x 67 Size: 48 x 48 x 67
Weight: 100gm (approx) Weight: 100gm (approx)
Only 11Pin *Add to code 08 = 8Pin
*Add to code 11 = 11Pin
Ordering Code TYPE MODEL TYPE VOLTAGE TYPE MODEL TYPE VOLTAGE
RMC
Example 48 T100 11 230V 48 T101
* 230V 10 Sets / Pack

9 RHE
PROCESS CONTROLLERS
Type Control Module for resistive Level Control Module for
Liquid Level Control Module Liquid level controller
Sensors NAMUR Sensor

AFE AFE AFE


FAILSURES FAILSURES FAILSURES
FEAT FEAT FEAT

Code SC100 SC130 AC130 SC230


Features Senses conductivity between two Programmable for charging and Programmable for charging and Interfaces with industrial standard NA-
probe terminals providing a relay discharging operation discharging operation MUR sensors (inductive or capacitive)
output if conductivity exceeds a AC modulation of probe signal to AC modulation of probe signal to Low power sensor signal to DIN19234
set limit prevent plating and electrolytic prevent plating and electrolytic Programmable charge or discharge
AC modulation of probe signal to corrosion corrosion modes
prevent plating and electrolytic Low voltage, probe signal for Low voltage, probe signal for Programmable single or double
corrosion human safety human safety sensor selection
Low voltage probe signal for Adjustable sensitivity Adjustable sensitivity Independent indication of each
human safety sensor status
DC or AC power supply option Power ON and RELAY ON LEDs
Adjustable sensitivity from 15k to
10A SPDT relay output 5A SPDT or DPDT relay output Separate cable fault indication for
500k Ohm
each sensor
10A SPDT relay output
Failsafe operation under cable fault
Possible Applications: conditions
Direct interface with solid state relay
Liquid Level Control
Protected NPN output for direct
Flame Detection / Daylight Switching
interface with PLCs or counters
Temperature Control
10A SPDT relay output
Soil Moisture Monitoring
DC or AC power supply option
Remote Start/Stop
Connection
Diagram

DPDT on request DPDT on request DPDT on request. No Solid State Output


Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY
AC: (AC only - see SC130 for DC AC: Supply voltage: 12, 24, 115, 230, AC: Transformer (2kV galvanic AC: Supply voltage: 12, 24, 115, 230,
applications) 400, 415, 525V 15% isolation): Supply Voltage: 12, 24, 400, 415, 525 15%
Supply voltage: 12, 24, 115, 230, Isolation (probe input to power 115, 230, 400, 525VAC Isolation (sensor input to power supply):
400, 415, 525V AC 15% supply): 2kV Power consumption: 2VA (approx) 2kV
Isolation (probe input to power Power Consumption: 3VA, 6VA for 415, Tolerance: 15% Power consumption: 3VA, 6VA for 415,
supply): 2kV 525V (approx) DC: Supply voltage: 48, 60, 110V 525V (approx)
Power consumption: 3VA, 6VA for DC: Supply voltage: 10-30V, 48, 60, Power Consumption: 30mA (approx) DC: Supply voltage: 10-30V, 48, 60, 110V
415, 525V (approx) 110V 15% AC/DC: Supply Voltage: 12 - 24V 15%
PROBE INPUT Isolation: no galvanic isolation Power Consumption: Isolation: no galvanic isolation
Sensitivity: approx. 15-500k Ohm Power consumption: 100mA (10-30V), 100mA (approx) Power Consumption: 100mA (10-30V),
(adjustable) 30mA for higher ranges Tolerance: 15% 30mA for higher ranges
Probe voltage: 12V AC LEVEL SENSING INPUT HOUSING SENSOR INPUT
Probe frequency: 50Hz Probe voltage: 4V AC 250V and below: 22,5mm width Type NAMUR (DIN 19234)
Probe frequency: 100Hz Above 250V: 45mm width Maximum Sensing Speed: 25Hz
Sensitivity: 0 - 50kOhm (adjustable) LEVEL SENSING INPUT (when using relay output)
Response time: 0,5 seconds Probe voltage: 4V AC Short Circuit Current: 20mA DC
Probe frequency: 100Hz Open Circuit Voltage: 8,2V DC
*For Probe parts, see page 48 Sensitivity: 0 to 100kOhm
(adjustable) OUTPUTS (SP)
Response: 0.5 seconds NPN Open Connector (9,11)
RELAY Solid State Relay Drive (8,9)
Relay Contacts (250V, 5A): SPDT, C/O (1,3,4)
DPDT.
*Relay contact
If DP Contacts, no solid state O/P
SP= Single Pole
*For probe parts see page 48
DP= Double Pole

Ordering Code TYPE MODEL VOLTAGE POWER


SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS

Example SC 100 230V AC


* SC 130 230V AC
* AC 130 230V AC
* SC 230 230V AC
*

RHE
RHE 10
PROCESS CONTROLLERS
Control Module for Intrinsically Safe Control 3-Wire DC Sensor Interface
Type Tachometer Relay
NAMUR Sensor Module for NAMUR Sensor Relay Module

AFE AFE
FAILSURES FAILSURES
FEAT FEAT

Code SC300 SC301 SC314 SC320


Features Direct interface with Namur two- Intrinsically safe classification: Interfaces with all types of 3-wire Direct interface with Namur
wire proximity sensors (inductive, (Ex ib) Gr 2C, T6. NPN or PNP DC sensors two-wire proximity sensors or
capacitive and opto-electronic) Direct interface with Namur two (inductive, capacitive and limit switches
Sensor cable fault detection with wire proximity switches optoelectronic) Low power sensor signal to
LED indication Failsafe operation LED indication of relay status DIN19234
Proximity switching in hostile Sensor cable fault detection and Robust power supply Sensor cable fault indication
supply voltage environments indication Cost efficient interface for DC Programmable speed ranges:
(transients, surges) Low power sensor signal to sensors in AC environments 10 RPM to 10 000 RPM
High reliability proximity switching DIN19234 Cost efficient module replacement Programmable for over-speed
compared to limit switches SPST relay outputs 10A SPDT relay output or under-speed detection
Cost efficient sensor and module 0 to 1mA proportional output
replacement for tachometer instruments
Impervious to interference between 4-20mA available on request
sensor and amplifier over long cable
Speed set point adjustable on
runs
calibrated scale 0-100%
Low power sensor signal to
Start-up delay
DIN19234
10A SPDT relay output
10A single pole or 2 x 5A double
pole relay outputs Note: Analogue output not
available when DP option selected
Connection
Diagram

DPDT on request DPDT on request DPDT on request DPDT on request


Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY
AC: Supply voltage: 12, 24, 115, AC: Supply voltage: 115, 230V AC: Supply voltage: 12, 24, 115,
230, 400, 415, 525V 15% 15% 230, 400, 415, 525V 15%
Isolation (sensor input to power Isolation (sensor input to power
Isolation (sensor input to power
supply): 2kV supply): 2kV
supply): 2kV Power consumption: 3VA, 6VA for
Power consumption: 3VA, 6VA for Power consumption: 3VA 415, 525V (approx)
415, 525V (approx) approximately DC: Supply voltage: 10-30V, 48,
DC: Supply voltage: 10-30V, 48, DC: Supply voltage: 24V 15% 60, 110V 15%
60, 110V 15% Isolation: no galvanic isolation Isolation: no galvanic isolation
Isolation: no galvanic isolation Power consumption: 100mA Power consumption: 100mA (10-
SENSOR INPUT 30V), 30mA for higher ranges
Power consumption: 100mA (10- SENSOR INPUT
30V), 30mA for higher ranges Type: Namur (DIN 19234) Type: Namur (DIN 19234)
SENSOR INPUT Quiescent Voltage: <8.2V DC Short Circuit Current: 20mA DC
Short circuit current: < 25mA SUPPLY VOLTAGE
Type: NAMUR (DIN 19234) Open Circuit Voltage: 8,2V DC
Max External Capacitance: AC: Supply Voltage: 12, 24, 115, Hysteresis: 10% (fixed)
Maximum Sensing Speed: 25Hz
< 300nF (AC supply), < 700nF 230, 400, 415, 525V 15% Repeatability: 1%
Short Circuit Current: 20mA DC
(DC supply) Isolation (sensor input to power Start-up delay: approximately 10
Open circuit voltage: 8,2V DC supply): 2kV seconds (Available 0-15 seconds
Max External Inductance: < 2mH on special order)
Relay options: SPST (pins 1 & 3, Power consumption: 3VA, 6VA for
415, 525V (approx) Analogue output: 0-1mA DC**
NO), DPST (pins 1 & 3 NO / pins 11 (0-20mA or 4-20mA - available as an
& 9, NO) DC OUTPUT SUPPLY FOR output order option)
Maximum relay current: 5A SENSORS Maximum load: 7k Ohm
Maximum relay voltage: 250V 10-15V at 30mA Accuracy: 5% of full scale
Maximum product of relay current SENSORS INPUT: (PNP pin 5, Speed Range Approximate
and voltage: 100VA NPN pin 8) Response time
Internal fuse rating: (AC supply) Each sensor must be able to 10-100 RPM 10 seconds
*Relay contact 100mA, 250V conduct at least 80mA to operate 30-300 RPM 10 seconds
SP= Single Pole the modules internal relay 100-1 000 RPM 1 second
DP= Double Pole Maximum switching speed: 25Hz 300-3 000 RPM 1 second
(when using relay output) 1 000- 10 000 RPM 1 second
Ordering Code TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER OUTPUT
SUPPLY
RELAY
CONTACTS

Example SC 300 230V AC * SC 301 230V AC * SC 314 230V AC SP SC 320 230V AC ** *

11 RHE
PROCESS CONTROLLERS
Thermistor Motor Protection Flip Flop Relay with/without
Type Opto-electronic Control Unit Temperature Control Module
Module Memory

AFE AFE AFE


FAILSURES FAILSURES FAILSURES
FEAT FEAT FEAT

Code SC410/SC411 SC501 SC510/SC511 SC610/SC611


Features Directly interfaces with the R02 Interfaces with industrial standard Interfaces with PTC sensors as Many power supply options
Detector range of rectangular and PT-100 temperature sensors per DIN 44081 Direct connection of a NPN
tubular opto-electronic sensors Six programmable overlapping The SC511 has a fault latching sensor (SC611)
10 metre sensing distance with the temp. ranges between -50 - 300C feature, can be reset via external SC610 - without memory
appropriate barrier heads Programmable for over and under opening contact or via the reset SC611 - with memory
Programmable for dark or light temperature button on the unit 10A SPDT or a 5A DPDT relay
response Temperature level adjustment on Test button to simulate fault
Adjustable on and off response calibrated scale 0 - 100% condition on the SC511
delay of 0-5 seconds High repetitive accuracy Sensor or cable fault detection
Signal modulated beam to stop Programmable inversion of relay and indication with an automatic
foreign light source interference output for fail-to-safe operation relay de-energisation for failsafe
Adjustable light intensity 0 to 1mA proportional output for operation
High speed solid state (NPN) open each temperature range 10A SPDT relay output
collector output Proportional output is limited to 1,2
Direct interface with solid state relays mA to protect analogue instruments
Opto sensor cable fault detection Latching on under-temperature or
(SC411 only) over-temperature (programmable)
10A SPDT relay output 10A SPDT relay output

Connection
Diagram

See page 327 for sensors. DPDT on request


(No Solid State Output) DPDT on request .No Latching DPDT on request DPDT on request
Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY
AC: Supply voltage: 12, 24, 115, AC: Supply voltage: 12, 24, 115, AC: Supply voltage: 12, 24, 115, AC: Supply voltage: 12, 24, 115,
230, 400, 415, 525V 15% 230, 400, 415, 525V 15%
Isolation (sensor input to power 230, 400, 415, 525V 15% 230, 400, 15%
Isolation (sensor input to power supply): 2kV Power consumption: 3VA, 6VA for Isolation (reset to power supply):
supply): 2kV Power consumption: 3VA, 6VA for 2kV
Power consumption: 3VA, 6VA for 415, 525V (approx)
415, 525V (approx) Power consumption: 3VA
415, 525V (approx) DC: Supply voltage: 12, 24V 15% DC: Supply voltage: 10-30V, 48,
DC: Supply voltage: 10-30V, 48, 15% Isolation: no galvanic isolation 60, 110V 15% (approx)
Isolation: no galvanic isolation Power consumption: 100mA Isolation: no galvanic isolation DC: Supply voltage: 12, 24, 48,
CONNECTION CABLE 60,110V 15%
(common negative) 2 - core, unscreened. Resistance of Power consumption: 100mA for
Power consumption: 100mA long cables affect temp. accuracy Isolation: no galvanic isolation
10-30V, 30mA for 48V and higher
(10-30V), 30mA for higher ranges (Approx.1C per 0.3 ohms) Power consumption: 100mA for
RESPONSE SENSOR INPUT SENSOR INPUT
12V and 24V, 30mA for 48V and
ON - Delay = 0.03 - 5 seconds Type PT-100 resistive temperature Type: PTC sensor as per DIN 44081 higher
(adjustable) sensor Input impedance: 2200 Ohms
Short-circuit current: 1mA 12V DC Output:
OFF - Delay = 0.03 - 5 seconds Open-circuit voltage: 220mV Open-circuit voltage: <=2.5V Voltage tolerance: 10-15V DC.
(adjustable) TEMPERATURE SENSING Short circuit current: 1mA (max) Source Current: 50mA (max.)
SOLID STATE RELAY OUTPUT RANGE - Repetitive accuracy: 1% MEASURING
(Pin 8-9) CHARACTERISTICS OF THE
Max. output source current: 8mA RANGE S1 INPUT
Open circuit output voltage: 12V DC SENSOR
-50 to 50 C 1 SC-610
TRANSMITTER ( Pin 6 - 7) 0 to 100 C 2 Maximum cold resistance of PTC
Short circuit current: 8.5mA
Current pulse: 1.5A/25 microseconds 50 to 150 C 3 sensor: 1500ohms (i.e. 1 to 6
Maximum wire impedance: 2,5 100 to 200 C 4 sensors can be connected) Open Circuit Voltage: 8.2V
Ohms (use coaxial cable) 150 to 250 C 5 Triggering threshold: 3100 Ohms
200 to 300 C 6 Input reset speed: 20 millisecs.
Short circuit current: 20 mA (average) 10%
RECEIVER (Pin 5 - 6) ANALOGUE OUTPUT SC-611
Short circuit current: 3mA Recovery threshold: 1650 Ohms
Rating 0 to 1mA (proportional)
Open circuit voltage: 8.2V 4-20mA available as an order option 10% Short circuit current: 1mA
OPEN COLLECTOR on any one range Short-circuit detection: < 20ohms Open Circuit Voltage: 8.2V
*Relay contact TRANSISTOR OUTPUT (Pin 9-11) Maximum voltage between pins 7 Open-circuit detection: 10k 10%
Input reset speed: 10 millisecs.
Type: NPN transistor and 11 (pin 11 positive): 12V DC
SP= Single Pole Maximum load: 7k Ohm. Current Repetitive accuracy: 0,5%
DP= Double Pole Output sink current: 100mA limits at 1.2mA to protect analogue Response Time: 50 milliseconds
Maximum voltage: 30V DC instruments
Ordering Code TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS

Example SC 610 230V AC *


SC 410 230V AC
* SC 501 230V AC
* SC 510 230V AC
*
RHE
RHE 12
PROCESS CONTROLLERS & COUNTALINE
Multi-function Preselect
Type Power Supply Module Totalising Counter Preselect Counter
Counter

Code SC900 CC120 SC700 CC701


Features Cost effective power supply. Large 6-digit LED display with leading High & low speed inputs in one unit High & low speed inputs in one unit
A large variety of output supply zero suppression Selectable ADD, SUBTRACT or Relay hold time programmable from
options (see table below) High speed count input (5kHz) with ADD/SUBTRACT count modes 0,1 - 25 seconds in 0,1 second
High input voltage ranges (up positive or negative active edge (order Relay hold time programmable increments
Reset achieved via the front panel
to 525V AC) option) from 0,1 - 25 seconds in 0,1
push-button, via external switch or
Ease of installation due to Independent low speed count input seconds increments via NPN sensors
11-pin plug-in concept (30Hz) suitable for mechanical sensors Reset achieved via the front DC (NPN or PNP) or Namur
Reset achieved via the front panel panel push-button, via external sensor compatible high speed input
push-button, via external switch or via switch or via NPN sensors (order option)
NPN sensor DC (NPN or PNP) or Namur Large 4-digit display with leading
Gate input for ignoring high speed count sensor compatible high speed zero suppression
input pulses and gate inputs (order option) Separate up and down count inputs
DC (NPN or PNP) or Namur sensor Tamperproof keylock feature for in ADD/SUBTRACT mode 1
compatible high speed and gate inputs protection of programmed Separate count and count direction
input in ADD/SUBTRACT mode 2
(order option) parameters User friendly keypad programming
48 x 72mm panel mount housing format 11-pin plug-in format (Industrial 48 x 48mm (1/16 DIN) panel
Standard) mounting housing format
Connection
Diagram

Specifications INPUT SUPPLY VOLTAGE INPUT SPECIFICATIONS INPUT SPECIFICATIONS INPUT SPECIFICATIONS
AC: Supply Voltage: 12, 24, 115, Namur: High Speed & Gate Input: AC/DC: Supply voltage: 24V 15% High speed input:
230, 400, 415, 525V 10% Namur sensor DIN 19234 Isolation: No galvanic isolation Namur: Namur sensor DIN 19234
Reset Input: Potential free contact/NPN sensor Power consumption: 100mA DC: NPN or PNP sensor
Isolation ( input to input): 2kV
Slow Speed Input: Potential free contact Low speed input: Maximum input frequency: 500Hz
Power consumption: 6VA (approx) or NPN sensor Input type: potential-free contact or NPN Minimum pulse width: 1 millisecond
OUTPUT SUPPLY VOLTAGE DC: High Speed & Gate Input: NPN/PNP sensor sensor Active pulse edge: Positive or Negative
Type: AC, DC, DCRG Reset Input; Potential free contact/NPN sensor Maximum count frequency: 30Hz Slow speed input:
Output Voltage: 12, 24, 36 Slow Speed Input: Potential free contact
Minimum pulse width: 16.7ms
or NPN sensor Namur & DC: Potential free contact or
AC Supply (10%) Output High speed input: NPN sensor (open collector type)
Current: 300mA, 150mA,100mA Max. Input frequency: High Speed Input: 5kHz
Gate & Reset Input: 1kHz Maximum count frequency: 1kHz Maximum input frequency: 30 Hz
DC Unregulated (10%) Minimum pulse width: 500Hz Minimum pulse width: 16.7 ms
Slow Speed Input: 30Hz
Output Current: Minimum pulse width: High Speed RESET INPUT Active pulse edge: Positive or Negative
200mA, 120mA, 100mA Input: 100 microseconds Minimum pulse width: 500ms RESET INPUT: Namur & DC: Potential
% Ripple: <5 Gate & Reset Input: 500 microseconds SENSOR INTERFACE free contact or NPN sensor
DCRG Regulated (1%) Slow Speed Input: 16.7microseconds Replace * with sensor type Maximum input frequency: 500Hz
Output Current: Active pulse edge: *D= PNP/NPN Minimum pulse width: 1 millisecond
150mA, 100mA, 80mA High & slow Speed Input: Positive or *N= Namur Active pulse edge: Negative: holds count
% Ripple: <0,5 negative, Namur and DC Namur: 8.2V DC/ 10mA value. Positive (if low for < 2 sec): resets
Gate Input: Low level on input DC (NPN/PNP):12V DC/ 50mA count value and clears error messages
SENSOR INTERFACE Max. NPN sensor saturation voltage: 2VDC SENSOR INTERFACE
Replace* with sensor type OUTPUT SPECIFICATIONS Replace* with Sensor Type
1= Namur negative edge Solid state relay: 12V at 10mA *D= PNP/NPN
2= Namur positive edge
GENERAL SPECIFICATIONS *N= Namur
3= Negative - NPN/PNP(DC)
4= Positive - NPN/PNP(DC) Supply voltage: Replace** with Namur: 8.2V DC / 10mA
Namur option: 8.2V DC/10mA 12VDC, 24VAC/DC, 115VAC, 230VAC, NPN or PNP sensor: 12V DC/ 30mA
DC (NPN or PNP) option:12V DC/ 50mA 400VAC, 415VAC, 525VAC Max.NPN sensor saturation voltage: 2V
Max. NPN saturation voltage: 2V DC Maximum count frequency exceeded: DC, 2.5V DC
(high speed count and gate inputs)2.5V 3 decimal points illuminating Maximum PNP sensor saturation
DC (low speed count input) Power supply interruption < 1 second: voltage: 2V DC (high speed count input)
Max. PNP sensor saturation voltage: 2V 3 decimal points flashing OUTPUT SPECIFICATIONS
DC (high speed count and gate inputs) Relay ON time: Adjustable range: Relay: 250 VAC, 8A, SPDT
*Add to code output type GENERAL SPECIFICATIONS 0.1 to 25 seconds SSR Drive: 10mA at 6V
Supply voltage: Replace ** with 24VAC/DC, Resolution: 0.1 second repeatable 1% GENERAL SPECIFICATIONS
AC = AC 110VAC,230VAC, 400VAC, 415VAC, 525VAC Set-up and data retention: 10 years Supply voltage: Replace** with
DC = DC (UNREGULATED) Protection class : IP 54 (front), IP30 (rear) 12VAC, 12VDC, 24VAC, 24VDC, 48VAC,
DCRG = DC (REGULATED) Connection: Plug-connector 115VAC, 230VAC, 400VAC
Ordering Code
AC OUTPUT OUTPUT
VOLTAGE TYPE MODEL ACTIVE POWER TYPE MODEL VOLTAGE SENSOR RELAY TYPE MODEL VOLTAGE SENSOR RELAY
TYPE MODEL VOLTAGE TYPE
EDGE SUPPLY TYPE CONTACTS TYPE CONTACTS

Example CC 120 * ** SC 700 ** * SP CC 701 ** * SP

13 RHE
RHE
PUMP MOTOR PROTECTION
Motor System, Protection Relay Motor System, Protection Relay Motor System, Protection Relay Motor System, Protection Relay
Type Underload Reset Timer, Variable Underload Monitor, Underload Reset, Timer, Three Variable Underload Monitor,
Single Phase Single Phase Phase Three Phase

Code MP820 MP825 MP830 MP835


Features Underload sensing by measuring Underload sensing by measuring Underload sensing by measuring Underload sensing by measuring the
the phase angle the phase angle the phase angle phase angle
Adjustable restart time after Underload sensitivity adjustment Adjustable restart time after Underload sensitivity adjustment after
detection of underload conditions after calibration of phase angle detection of underload conditions calibration of nominal phase angle
Overload sensing by measuring Overload sensing by measuring the Overload sensing by measuring the Overload sensing by measuring the
the current amplitude current amplitude current amplitude current amplitude
Microprocessor-based technology Microprocessor-based technology Microprocessor-based technology Microprocessor-based technology
Direct in-line current sensing of Direct in-line current sensing of Direct in-line current sensing of Direct in-line current sensing of
motors up to loads above 1.1kW motors up to 1.1kW motors up to 3.7kW motors up to 3.7kW
Direct interface with a conventional Auto-calibration of overload/voltage Auto-calibration of overload/voltage Auto-calibration of overload/voltage
current transformer and underload/voltage limits and underload/voltage limits and underload/voltage limits
Auto-calibration of overload/voltage Direct interface with a conventional Direct interface with a conventional Direct interface with a conventional
and underload/ voltage limits current transformer current transformer current transformer
Liquid level control Liquid level control Phase sequence and phase failure Phase sequence and phase failure
Latching on overload conditions Start-up delay detection detection & Liquid level control
Start-up delay (3 secs standard) Latching on underload and overload Liquid level control Latching on underload and overload
Latching on overload conditions conditions Latching on overload conditions conditions
Fail-to-safe design Fail-to-safe design Fail-to-safe design Fail-to-safe design
Din-rail mount Din-rail mount Din-rail mount Din-rail mount
5A SPDT relay output 5A SPDT relay output 5A SPDT relay output 5A SPDT relay output

Connection
Diagram

Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY


Supply Voltage: 230VAC Supply Voltage: 230VAC Supply Voltage: 400VAC, 525VAC Supply Voltage: 400VAC, 525VAC
Supply Voltage Tolerance: Supply Voltage Tolerance: Supply Voltage Tolerance: Voltage Tolerance:
AC, 176 - 288V AC AC, 176 - 288V AC AC, 304 - 498V AC, 420 - 630V AC 304 - 498V AC, 420 - 630V AC
Power Consumption: 4VA (approx) Power Consumption: 4VA (approx) Power Consumption: 4VA (approx) Power Consumption: 4VA (approx)
Isolation (current input to power Isolation (current input to power
supply): Isolation (current input to power Isolation (current input to power
supply): 2kV supply): 2kV supply): 2kV
2kV Supply frequency: 50/60Hz
Supply frequency: 50/60Hz Supply frequency: 50/60Hz Supply frequency: 50/60Hz
RESPONSE RESPONSE RESPONSE
RESPONSE
Start-up Delay: 3 seconds fixed, Start-up Delay: 3 seconds fixed, Start-up Delay: 3 seconds fixed, Start-up Delay: 3 seconds fixed,
standard (extended times available on standard (extended times available
standard (extended times available standard (extended times available
request) Response Delay: Overload 3 on request)
on request) on request) Response Delay: Overload 3
seconds. On all other faults 1 second Response Delay: Overload 3 sec Response Delay: Overload 3
RESTART seconds Phase sequence/ failure
RELAY: 250V, 5A SPDT seconds Phase sequence/ failure instantaneous on all other faults 1
Restart Timer (underload): 15 min - 24
hrs (adjustable) Reset lockout: Max. 3 RESTART: Reset lockout: Max 3 instantaneous on all other faults 1 second
resets per 15mins resets per 15mins second RESTART
CURRENT INPUT CURRENT INPUT RESTART: Restart Timer Reset lockout: Max. 3 resets per 15
Motors <1.1kW: Motors <1.1kW: (underload): 15 min - 24 hrs minutes
Current limits to ensure calibration: 0,5 Current limits to ensure calibration: (adjustable). Reset lockout: Max. 3 RELAY
to 10A 0,5 to 10A resets per 15mins 250V, 5A SPDT
Repetitive accuracy: 1% Repetitive accuracy: 1% RELAY: 250V, 5A SPDT CURRENT INPUT
Maximum input current (continuous): Maximum input current CALIBRATION Motors <3.7kW:
15A (continuous) 15A Phase Angle Limits: Current limits to ensure calibration:
Motors >1.1kW: (use external CT) 0,5 to 8A
Motor: 1.5kW, 2.2kW Motors >1.1kW: (use external CT) Underload: 90 or 125% of calibration
Motor:1.5kW, 2.2kW value Repetitive accuracy: 1%
Current Transformer: 20/5, 30/5 Maximum input current
CALIBRATION Current Transformer: 20/5, 30/5 Current Limits:
Phase Angle Limits: CALIBRATION Overload: 10A or 125% of calibration (continuous): 12A
Underload: 90 or 125% of calibration Phase Angle Limits: value. CALIBRATION
value Underload: 90 or 120 - 160% of Voltage Limits: 10% of calibration Phase Angle Limits:
Current Limits: Underload: 90 or 120 - 160% of
calibration value (underload) value
Overload: 13A or 125% of calibration calibration value
Current Limits: CURRENT INPUT Motors <3.7kW: Current Limits:
value Overload: 13A or 125% of calibration Current limits to ensure calibration: 0,5
Voltage Limits: 10% of calibration Overload: 10A or 125% of
value value to 8A. Repetitive accuracy: 1% calibration value
RELAY: Voltage Limits: 10% of calibration Maximum input current (continuous): Voltage Limits: 10% of calibration
250V, 5A SPDT value 12A value
LEVEL CONTROL: LEVEL CONTROL LEVEL CONTROL LEVEL CONTROL
Sensitivity: 50 k Sensitivity: 50 k Sensitivity: 50 k Sensitivity: 50k
Ordering Code TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER
SUPPLY
RELAY
CONTACTS
TYPE MODEL VOLTAGE POWER RELAY
SUPPLY CONTACTS

Example MP 820 230V AC SP MP 825 230V AC SP MP 830 AC SP MP 835 SP

RHE 14
DIN RAIL MOUNT TIMERS RELAYS
Type Delay on Timer Multifunction Timer Star Delta Timer Passage Light Timer Unequal Cycling Timer

(Replace *
with relay
type.)

(Replace *
with supply
voltage.)

Code ZHRT1-A - */ * ZHRT1-M - */ * ZHRT1-ST/ * ZHRT1-LS/ * ZHRT1-S2-/ *


Output Replace * in Code with Replace * in Code with 2 x NO 1 x NO 2 x C/O
*2 = 2 x Timed C/O *2 = 2 x Timed C/O
*2T = 1 x Timed + 1 x *2T = 1 x Timed + 1 x
Instantaneous C/O Instantaneous C/O

Relay
5A@250VAC 5A@250VAC 5A@250VAC 10A@250VAC 5A@250VAC
Rating
Function Microprocessor based Microprocessor based Microprocessor based Microprocessor based Microprocessor based
LED indication of supply LED indication of supply LED indication of supply Control of stairwell LED indication of supply
and relay state and relay state and relay state. or Passage Lighting and relay state
On application of power 10 Independant operating Start time adjustable When the unit receives a Time ranges from 0.1s to
the time function starts. functions: 1s - 10min. pulse input (L/N) the relay 100Hr
At the end of time delay A - Delay on operate Pause time adjustable operates for the preset time. Timing Functions start on
the relay operates B - Delay on Release 20ms - 300ms. At the end of the set time it application of power supply.
The unit is reset by removal C - Cycle timer OFF first The unit is reset by removal switches of automatically. The unit is reset by removal
and re-application of power D - Cycle timer ON first and re-application of power LED indication of supply and re-application of power
supply E - Interval hold reset supply and relay state supply.
Wide time range of F - Interval pulse reset Auto or Manual Mode
0.1s to 100Hr G - Delay OFF hold reset Time Range adjustable:
H - Delay ON/OFF pulse 30s - 20min
reset
I - Latching pulse reset
J - Pulse Generator
Wide time range of
0.1s to 100Hr

*D12 = DC12V *D12 = DC12V *A110 = AC110V *A110 = AC110V *AD240 = AC/DC 24-240V
Supply *AD240 = AC/DC 24-240V *AD240 = AC/DC 24-240V *A230 = AC230V *A230 = AC230V *A110 = AC110V
Voltage
*A400 = AC400 *A400 = AC400V *A400 = AC400V *A400 = AC400V *A400 = AC400V
Diagram

15 RHE
VOLTAGE MONITORS
Type 3 Phase 3 Phase 3 Phase
Over and Under 3 Phase
Phase Failiure/ Over/Under Voltage, Over or Under Over/Under Voltage,
Voltage Monitor Phase Sequence/
Sequence/ Phase Sequence/ Voltage Monitor Phase Sequence/
(Comparator) Failure/Asymmetry
Asymmetry Failure/Symmetry Failure/Symmetry

(Replace *
with supply
voltage.)

Code ZHRV3-01-Z/ * ZHRV3-07-Z/ * ZHRV5-01/ * ZHRV5-02/ * ZHRV5-09/ * ZHRV5-11/ *


Output 2 x C/O 2 x C/O 1 x C/O 1 x C/O 1 x C/O 1 x C/O
5A@250VAC 5A@250VAC 5A@250VAC 5A@250VAC 5A@250VAC 5A@250VAC

Function Phase Sequence/Failure Phase Sequence/Failure Selectable Operating Over & Under Voltage Phase Sequence/Failure Phase Sequence/Failure
Asymmetry 5-15% Overvoltage 2-20% Modes: Levels adjustable Overvoltage 2-20% Asymmetry 8%
Trip Delay 0.1-10s Undervoltage 2-20% - Over Voltage Latching (Dependant on supply Undervoltage 2-20% Trip Delay 2s
Reset Time 0.1-10s Asymmetry 5-15% - Over Voltage Non- voltage). Asymmetry fixed 8%
Trip Delay 0.1-10s Latching Fixed Hysteresis: 5% Trip Delay: 0.1-10s
Reset Time 0.1-10s - Under Voltage Latching Time Delay: 0.1-10s
- Under Voltage Non-
Latching
Microprocessor based Microprocessor based Voltage threshold Microprocessor based Microprocessor based Microprocessor based
True RMS measurement True RMS measurement adjustable (Dependant True RMS measurement True RMS measurement True RMS measurement
8 Nominal voltage 8 Nominal voltage on Supply Voltage) Monitor AC or DC 8 Nominal voltage 8 Nominal voltage
operating ranges operating ranges Hysteresis: 5-20% LED indication of Operating Ranges Operating Ranges
LED status indication LED status indication Time Delay: 0.1-10s control state. LED status indication. Frequency Range:
Trip/Reset delay Trip/Reset delay Microprocessor based 45-65Hz
adjustable adjustable True RMS measurement LED status indication
Suitable for either 3 Suitable for either 3 Monitor AC or DC.
or 4-Wire systems or 4-Wire systems LED indication of
control state.
*M440 = AC 208V-440 *M440 = AC 208V-440 *D12 = DC12V *D12 = DC12V *M460 = AC 220V-440V *M460 = AC 220V - 440V
(8 Set Points-P/P) (8 Set Points-P/P) *AD48 = AC/DC 24-48V *AD48 = AC/DC 24-48V (8 Set Points-P/P) (8 Set Points-P/P)
*M254 = AC 120V-254V *M254 = AC 120V- 254V *AD240 = *AD240 = Frequency Range Frequency Range
(8 Set Points-P/N) (8 Set Points-P/N) AC/DC 110-240V AC/DC 110 - 240V 45 - 65Hz 45 - 65Hz
Frequency Range: Frequency Range:
45 - 65Hz 45 - 65Hz

ZHRV3-01-Z/M245 - 4 Wire

ZHRV3-01-Z/M440 - 3 Wire

RHE 16
PROTECTION RELAYS LIQUID LEVEL CONTROLLER
Type Motor Protector Type Liquid Level Control

(Replace * (Replace *
with trip with supply
current) voltage)

(Replace *
with supply
voltage)

Code ZHRA1-*/ * ZHRA5-* Code ZHRL1-A/*


Output 1 x C/O 1 x N/C Output 1 x C/O
5A@230VAC 1A@240VAC 250VAC@1.5A

Function Inverse time current protection, over- Does not require power supply. Function Charge and Discharge. (Fill & Drain)
load, phase failiure, phase assymetry Simplified wiring & installation. Adjustable Sensitivity: 5k - 100k.
and locked rotor protection. Overload, Phase Failure Protection Can operate as 2 or 3 probe system
LED Indication of status Thyristor Output. Adjustable delay to prevent false triggers: 0.1-10s
Current transformers integrated into LED Indication of status. LED indication of high/low water level
the body of the unit. Compact design. Low Cost. Supply *A110 = AC 110V
Current transformers integrated into Voltage *A230 = AC 230V
Various Current Ranges available: the body of the unit.
Connection 3-Wire (Drain)
Trip Current Motor Kw
Diagram
*1A-5A 0.5 - 2.5kW Various Current Ranges available:
*6A-30A 3 - 15kW Trip Current
*16A-80A 8 - 40kW *0.5A - 5A
*80A-400A 40 - 200kW *2A - 20A
*20A - 80A
Current adjustable within range. *64A - 160A
Adjustable start Delay: 2-30s
3-Wire (Fill)

Supply *AC230V No power supply required


Voltage *AC400V
Frequency Range 45 - 65Hz

Connection
Diagram
2-Wire (Drain)

2-Wire (Fill)

Direct Start with AC230V


contactor. For other configurations
see product data sheet.

17 RHE
SPECIAL PRODUCTS
Type Re-cycling Timer Control Module for Semi-Automatic
3-Phase Current Monitor Spark Detector
with Pause Namur Sensors Synchronising Unit
FAILSAFE
FEATURES

Code CM193 DT310/12 PSM1130/3 SAS110 SP08M


Features Ready to operate when the Unit starts with pause Transistorised switching Senses differences in voltage, Detects infra light from arcing or flames
current transformers and shunt mode amplifier for inductive proximity, frequency and phase angle Long dist. sensing and acc. location
resistor block-SR3 is connected Contacts totally isolated sensors to DIN19234 (Namur) between the generator and the Cost effective solutions, detection in
When power is applied the Adjustable pause time Available as a solid state or busbar system burners, boilers or fire detection equip.
relay energises immediately ranges relay output LED illuminates when all 3 In conjunction with a suitable infra light
LED indication showing Adjustable cycle time Selectable delay on output parameters match source, a high speed opto-barrier syst.
power ON ranges Programmable for metal Hysteresis setting for voltage Syst. consists of a Control Unit SP-08M
If the current on any of the 3 Whole cycle will sensing and non metal sensing Response delay 0,3 to 3 secs & side or front sensor heads SP-08S
phases fails below the set limit continuously LED indication for metal Adjustable voltage Initiates power shut down before
for at least one second, the repeat until power has sensed or no metal sensed synchronisation point, permanent damage is done
relay will de-energise and the been switch off LED indication when relay is 5-30V RMS The sensor heads can be connected in
LED extinguishes energised parallel and any sensor will trigger
the relay output
The module can be configured to latch
when arcing is sensed
Connection
Diagram

SPDT
DPDT AC or DC AC
POWER SUPPLY POWER SUPPLY SUPPLY VOLTAGE

Specifications POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY
AC: Supply voltage: 115, 230, AC: Supply voltage: 48, AC Transformer: Supply Voltage: AC: Supply voltage:115, 230, AC: Supply Voltage: 12, 24, 115, 230,
400, 415, 525V 15% 60, 115, 230, 400, 415, 12, 24, 48, 60,115, 230V 15% 400, 415, 525V 15% 400V
Power consumption: 3VA 525V 15% Operating frequency: 40-60 Hz Power consumption: 3VA, 6VA Power Consumption: 3VA(approx)
(approx), 6VA for 415, 525V Power consumption: 3VA Isolation test voltage: 2KV for 415, 525V (approx) Isolation: 2kV (voltage input to power
(approx) (approx), 6VA for 415, Power Consumption: 2,5VA Over voltage protection: 50% supply)Tolerance: 15%
Isolation: no galvanic isolation 525V (approx) Overvoltage protection: 50% for for 1 minute
Shunt resistor block - SR3 - DC: 24V only. 1 min(50Hz) GENERAL
1Amp or 5 Amp DC: Supply Voltage: 24V, 15% Red Phase: Weight: 190g
Max. ripple: 100% (above 50Hz)
GENERAL Over voltage protection: 750V Colour: Blue
Power Consumption: approx. 1,5W
GENERAL Weight: 190g Overvoltage protection:100% for
Weight: 190g Colour: Blue 1 min. on 24VDC GENERAL Sensor Head, to be ordered separately
Colour: Blue Rating for continuous op.:100% ED Weight: 200g
Voltage stabilisation: Yes Colour: Blue
PAUSE TIME RANGES Transient protection: Yes
Operating temp.: -20 to +50
0,1 - 2 sec 1 - 20 min
0,3 - 6 sec
Supply interruptions: Will not react
3 - 60 min
1 - 20 sec 10 - 200min
to interruptions less than 30ms
3 - 60 sec 0,5 - 10 hrs TIMERS:
10 - 200 sec 1 - 20 hrs Input pulse length: 0,1 to 5 secs
30 - 600 sec 1 - 30 hrs Output hold time: 0,1 to 5 secs
Repeatability: approx. 1%
CYCLE TIME RANGES
Overall accuracy: approx. 5%
OUTPUT
0,1 - 2 sec 1 - 20 min Relay contact: 1x single pole Front sensing - SP08F
0,3 - 6 sec 3 - 60 min change over contact
1 - 20 sec Side sensing - SP08S
10 - 200min Contact rating (resistive load):
3 - 60 sec 0,5 - 10 hrs 380VAC - 10A - 2500VA
10 - 200 sec 1 - 20 hrs Contact isolation:2500V
30 - 600 sec 1 - 30 hrs
SOLID STATE
*Relay contact Type: Open collector transistor
SP= Single Pole Output sink current: 100mA/12VDC
DP= Double Pole GENERAL
Weight: 190g Colour: Blue

RELAY
Ordering Code
RELAY
TYPEMODEL SHUNT VOLTAGE POWER CON- TYPE MODEL VOLTAGE POWER CON- TYPE MODEL VOLTAGE POWER RELAY TYPE MODEL VOLTAGE POWER TYPE MODEL VOLTAGE POWER
SUPPLY TACTS SUPPLYTACTS SUPPLY CONTACTS SUPPLY SUPPLY

Example CM 193
* * AC
*
DT 301/12 230V AC
* PSM 1130/3 230V AC SP SAS 110 230V AC SP 08M 230V AC

RHE 18
DIGITAL PANEL METERS
Type AC Voltage Meter AC Ampere Meter DC Voltage Meter DC Ampere Meter Frequency Meter
Size:
48 x 48mm
Cutout:
45 x 45mm

Code DHC8P-VAC DHC8P-AAC DHC8P-VDC DHC8P-ADC-* DHC8P-HZ


Display 999 (3 digit) 0.56 inch LED 999 (3 digit) 0.56 inch LED 999 (3 digit) 0.56 inch LED 999 (3 digit) 0.56 inch LED 3 digit 0.56 inch LED
Power Supply 100-240VAC/ DC 100-240VAC/ DC 100-240VAC/ DC or 100-240VAC/ DC 100-240VAC/ DC
12 - 60VDC 12 - 60VDC (Shunt 60mV)

Input Direct: 600V, 99.9V, CT(5A), 5A, 10A, 15A, 20A, Direct: 600V, 99.9V, *Shunt (50mV, 60mV, 150mV): 0.2-400Hz
9.99V, Selectable 30A, 40A, 50A, 9.99V selectable 5A, 10A, 15A, 20A, 30A, 40A,
60A,70A,80A, 90A, 100A, 50A, 60A, 70A, 80A, 90A, 100A,
200A, 300A, 400A, 500A, 150A, 200A, 300A, 400A, 500A,
600A, 700A, 800A, 900A, 600A, 700A, 800A, 900A, 999A,
999A, Selectable Selectable

Accuracy 0.5% 1 digit (at 25C) 0.5% 1 digit (at 25C) 0.5% 1 digit (at 25C) 0.5% 1 digit (at 25C) 0.2% 1 digit (at 25C)
Type AC Voltage Meter AC Ampere Meter DC Voltage Meter DC Ampere Meter Frequency Meter

Size:
72 x 72mm
Cutout:
68 x 60mm

Code DHC7P-VAC DHC7P-AAC DHC7P-VDC DHC7P-ADC-* DHC7P-HZ


Display 1999 (3 digit) 0.8 inch LED 1999 (3 digit) 0.8 inch LED 1999 (3 digit) 0.8 inch LED 1999 (3 digit) 0.8 inch LED 3 digit 0.8 inch LED
Power Supply AC/DC: 100~240V4VA AC/DC: 100~240V4VA 100-240VAC/ DC or 100-240VAC/ DC or AC/DC: 100~240V4VA
12 - 60VDC 12 - 60VDC (Shunt 60mV)
Input Direct: 600V, 199.9V, Direct: 5A Direct: 600V, 199.9V, 19.99V, *Shunt (50mV, 60mV, 150mV): 0.2-400Hz
19.9V, 1.999V, CT(5A), 10A, 15A, 20A, 1.999V, Selectable 5A, 10A, 15A, 20A, 50A, 100A,
Selectable 50A, 100A, 150A, 200A,
150A, 200A, 500A, 1000A, 1500A,
500A, 1000A, 1500A,
1999A, Selectable 1999A, Selectable
Accuracy 0.5% 1 digit (at 25C) 0.5% 1 digit (at 25C) 0.5% 1 digit (at 25C) 0.5% 1 digit (at 25C) Size: 96 x 48
Type AC Voltage Meter AC Ampere Meter DC Voltage Meter DC Ampere Meter Frequency Meter

Size:
48 x 96mm
Cutout:
45 x 92mm

Code DHC3P-VAC DHC3P-AAC DHC3P-VDC DHC3P-ADC-* DHC3P-HZ


Display Digit 1999 (3 digit) 0.56" LED 1999 (3 digit) 0.56" LED 1999 (3 digit) 0.56" LED 1999 (3 digit) 0.56" LED 3 digit 0.56" LED
Power Supply AC/DC: 100~240V4VA AC/DC: 100~240V4VA 100-240VAC/ DC 100-240VAC/ DC AC/DC: 100~240V4VA
Input Direct: 600V, 199.9V, Direct (5A) CT(5A): 5A, Direct: 600V, 199.9V, *Shunt (50mV): 5A, 10A, 0.2-400Hz
19.99V, 1.999V, 10A, 15A, 20A, 30A, 40A, 19.99V, 1.999V, Selectable 15A, 20A, 50A, 100A, 150A,
Selectable 50A, 60A, 70A, 80A, 90A, 200A, 500A, 1000A, 1500A,
100A, 150A, 200A, 300A, 1999A, Selectable
400A, 500A, 600A, 700A,
800A, 900A, 1000A,
1500A, 1999A selectable
Accuracy 0.5% 1 digit (at 25C) 0.5% 1 digit (at 25C) 0.5% 1 digit (at 25C) 0.5% 1 digit (at 25C) 0.1% 1 digit (at 25C)

19 DPM
RHE
DIGITAL PROCESS METERS
Programmable DC Ammeter or Process Meter
Size 48 x 96mm Accuracy CL 0.5 Decimal point & range adjustable
Code Description
DHC3P-SVA1 Input: 4-20mA, 0-20mA, 0-1V, 0-5V, 1-5V, 0-10V, 0-200mV
Supply: 110-240VAC/DC 2.5VA
Output: 0-12-24VDC
As DHC3P-SVA1 with 4-20mA
DHC3P-SVA2
Re-transmission output
DHC3P-SVA3 As DHC3P-SVA1 with high & low relay alarm output. N/O.

DIGITAL TIMERS & COUNTERS


Up / Down Total Counter
Type Timer Timer/ Counter Pre-Set Counter Hour Meter
Totalizing Counter

6 Timing Functions Auto or Manual Reset Auto or Manual Reset Manual or Electronic Reset
Code DHC48 DHC10J DHC5J DHC9J-J DHC15J
Size(mm) 48 x 48 x 92 48 x 48 48 x 48 x 92 36 x 72 x 77 2 Module DIN mount
Panel Cutout 45 x 45 45 x 45 45 x 45 33 x 68.5
Range Delay ON/ Interval/ Equal Timer: 0.01s-99h59m
0-9999 0-9999 0-99999999
Repeating. 0.01s-99h59m Counter: 0-9999
Counting Speed 30/500cps 30/1000cps 30/1000cps 10cps
Display 0.3 inch LED (4 digit) 2 line 4 digit LED 0.3 inch LED (4 digit) 0.56 inch LED (6 digit) 8 digit LCD display
Power Supply 100-240VAC/DC 100-240VAC/DC 100-240VAC/DC (12-24VAC/DC) 100-240VAC/DC 100-240VAC/DC
Input Signal Pulse Start & Reset Contact or solid-state [H]: Contact or solid-state [H]: 4~30V Contact or solid-state [H]:
DC 4-30V
4~30V [L]: 0~2V Input 4.7k [L]: 0~2V Input 4.7k 4~30V [L]: 0~2V Input 4.7k
Output 2 C/O 3A@250VAC 1 C/O 3A@250VAC 1 C/O 3A@250VAC - -
Memory Backup 10 years 10 years 10 years 5 years

TIME
DIGITAL SWITCHES
TIMERS & COUNTERS
DIN Rail Electronic Time Switches
24 Hour 7 Day 7 Day
Easy to program
Manual ON/ OFF/ AUTO override
LCD Display with backlight
A
20for
ers
ys
Ge

Code DHC20 DHC15A DHC15A-20A


No of Channels 1 1 1
Time Range 24 Hours 24 Hours / 7 Days 24 Hours / 7 Days
No of Programs 48 On / 48 Off 8 On / 8 Off 8 On / 8 Off
Working Reserve 150 Hours 150 Hours 150 Hours
Minimum Interval 15 min 1 min 1 min
DIN Width 3 Modules 2 Modules 2 Modules
Relay Output SPDT 16A SPDT 16A SPDT 20A

DPM
RHE 20
INDUSTRIAL RELAYS
Type 8 Pin Plug-in Relay Flat 14 Pin Plug-in Relay Flat 8 Pin Plug-in Relay Flat 14 Pin Plug-in Relay Flat

RELAYS
- Test button function
- Flag plus LED
- Orange for AC
- Blue for DC

Relay Type 2 Pole Change Over (5A) 4 Pole Change Over (5A) 2 Pole Change Over (10A) 4 Pole Change Over (10A)
*AC *DC *Add voltage to code *Add voltage to code *Add voltage to code *Add voltage to code
230VAC R5502-*L R5504-*L R5602-*L R5604-*L
110VAC 110VDC R5502-*L R5504-*L R5602-*L R5604-*L
48VAC 48VDC R5502-0*L R5504-0*L R5602-0*L R5604-0*L
24VAC 24VDC R5502-0*L R5504-0*L R5602-0*L R5604-0*L
12VAC 12VDC R5502-0*L R5504-0*L R5602-0*L R5604-0*L
Wiring Diagram

Bases for R5502 & R5504 Relays 300V/10A Bases for R5602 & R5604 Relays 300V/10A
Screw Terminal Base IP20 Screw Terminal Base IP20

RHE

RB944-14F ZM3VP ZM6V ZM8V


Code Description Code Description
RB943-08F 8 Pin blue base for 2 pole relays ZM6V Base for R5602
RB944-14F 14 Pin blue base for 2 & 4 pole relays ZM8V Base for R5604
ZM3VP 11 Pin black base for 2 & 3 pole relays
AB - Series Relays 10A Bases for AB2 & AB3 Relays 250V/10A
Screw Terminal Base IP20 Screw Terminal Base IP20
2 C/O 3 C/O Volts
10A 10A AC DC
AB2 AB3 12 VAC 12 VDC
AB2 AB3 24 VAC 24 VDC
ZAV/A ZACS
AB2 48 VAC 48 VDC
AB2 AB3 110 VAC 110 VDC Code Description
AB2 AB3 230 VAC ZAV/A Base for AB2 relay
RE1
ZACS P.C.B. base for AB2 relay
Interface Relays Bases for Interface Relays IP20

*Add coil voltage


to code: 230VAC,
110VAC, 24VDC,
12VDC
C12 Type C10 Type CSS-AZ S-12 Relay Bases in combination S-10M
Code Description Code Description
C10/A10/* 1 c/o 10A relay, plug-in type S-12 Base for C12 relay 250V/5A
C12/A21/* 2 c/o 5A relay, plug-in type S-10M Base for C10/C14 relay 250V/16A
CSS-AZ Solid-state relay, Input 5-32VAC Out switch 3A@250VAC

21 RHE
INDUSTRIAL RELAYS
Type 8 Pin Plug-in Relay 11 Pin Plug-in Relay 8 Pin Plug-in Relay 11 Pin Plug-in Relay
UL recognised, CE
approval

Colour coding:
Orange: AC
Blue: DC

Relay type 2 Pole Change Over (10A) 3 Pole Change Over (10A) 2 Pole Change Over (10A) 3 Pole Change Over (10A)
*AC *DC *Add voltage to code *Add voltage to code *Add voltage to code *Add voltage to code
240VAC R6002-*L R6003-*L
230VAC 220VDC R6002-*L R6003-*L C2/A20/* C3/A30/*
110VAC 110VDC R6002-*L R6003-*L C2/A20/* C3/A30/*
48VAC 48VDC R6002-0*L R6003-0*L C2/A20/* C3/A30/*
36VAC 36VDC R6002-0*L R6003-0*L C2/A20/* C3/A30/*
32VAC 32VDC R6002-0*L R6003-0*L C2/A20/* C3/A30/*
24VAC 24VDC R6002-0*L R6003-0*L C2/A20/* C3/A30/*
12VAC 12VDC R6002-0*L R6003-0*L C2/A20/* C3/A30/*
6VAC 6VDC R6002-00*L R6003-00*L C2/A20/* C3/A30/*
Features Test button function Test button function Test button function & Test button function &
Flag plus LED Flag plus LED Flag ind Flag ind
Wiring Diagram

Bases for R6002 & R6003 Relays 300V/10A Timers IP40


Screw Terminals IP20
Code Description
BUV-B BOV-B 8 Pin oval base blue
BUV-B 11 Pin oval base blue
RB750-08R 8 Pin rectangle base blue
RB750-08R RB740-11R 11 Pin rectangle base blue
Screw Terminals IP20 300V/10A
Code Description Code Description
RB083-08R 8 Pin rectangle base blue
CT2A * 8 Pin Delay OFF timer
RB113-11R RB083-08R RB113-11R 11 Pin rectangle base blue
CT3A * 11 Pin Delay OFF timer
Screw Terminals IP20 300V/10A
CT2B * 8 Pin Equal Repeating timer
Code Description CT3B * 11 Pin Equal Repeating timer
PM-S8D 8 Pin rectangle DIN mount base CT2E * 8 Pin Delay ON timer
PM-S11D 11 Pin rectangle DIN mount base
CT3E * 11 Pin Delay ON timer
Retainer clip secures relay to the socket protecting
against vibration CT2K * 8 Pin one-shot pulse start timer
PM-S8D PM-S11D
CT3K * 11 Pin one-shot pulse start timer
Bases for C2/A20 & C3/A30 IP20 250V/10A
CT2W * 8 Pin one-shot timer
Code Description
CT3W * 11 Pin one-shot timer
S2-B 8 Pin rectangle base
S3-B 11 Pin rectangle base *Add voltage to code:
Unique retainer clip securing module to socket S (9.5-18VDC),
providing protection against vibration. L (20-65VAC/DC),
M (90-150VAC/DC for timer A & K),
A - Series Relays - For use with fast-on connectors
U (180-265VAC/DC for timer A & K),
1 N/O 2 N/O 1 C/O Coil Volts
Type 30A 16A 16A
H (90-265VAC/DC for timer B, E & W)
AC DC
30A 1C/O, A1/1 A1/2 A1/A 12 VAC 12 VDC The module CT2 & CT3 are electronic timers which are
16A 2C/O A1/1 A1/2 A1/A 24 VAC 24 VDC designed to be inserted between a standard plug-in relay and its
A1/1 A1/2 A1/A 110 VAC socket, enabling the relay to be operated as a timer relay. The
A1/2 RE1 relay coil voltage must be in the range shown for each model.
A1/1 A1/2 A1/A 230 VAC

RHE
RHE 22
OPTO ELECTRONIC SENSORS
Type Opto - Proximity Opto - Barrier Sets Opto - Fork Sensor

Specifications IP66 IP66 IP67 IP67


Sensing Distance 2m 10m 5m 3.5mm
Supply Voltage Select control voltage when ordering SC410/SC411 control relay 10... 30VDC
Setting Sensitivity Trimmer Sensitivity Trimmer Sensitivity Trimmer
Output Current - - - 400mA
Current Comsumption - - - < 10mA
Voltage Drop - - - 2V max
Operation Mode Dark or Light Dark or Light Dark or Light Dark or Light
Operating Temperature 0...70 0...70 0...70 0...70
Dimensions

Code
Front Sensing RO2-5005P-NOMBC RO2-5010B-NOMBC (pair) RO2-1210B-NOMTC (pair)
Side Sensing RO2-2005P-NOMBC RO2-2010B-NOMBC (pair)
Fork Sensing PNP RO4-2003B-NOMBC
Fork Sensor PNP RO4-2503B-NOMBC
with remote sensitivity adjustment
Separate Parts (i.e. not Tx+Rx) RO2-1210T-NOMTC
Front Transmitter RO2-5010T-NOMBC RO2-1210R-NOMTC
Front Receiver RO2-5010R-NOMBC
Side Transmitter RO2-2010T-NOMBC
Side Receiver RO2-2010R-NOMBC
Wiring Diagram

SC410/SC411 (See Page 12)

**See Page 12 for Control Unit **See Page 12 for Control Unit

Intelligent Canline Sensor IP67 The Intelligent Can Line Sensor has been specifically designed and developed for detecting the presence and movement
of cans and automated can making and can filling lines. When interfaced with Programmable Logic Controller (PLC) the
sensors integrated intelligence released the PLC from time-consuming computing activities.

The Can Line Sensor is versatile enough to be used in a variety of applications.


Some of these are:
Gap-detection (missing cans)
CAN MATERIAL Sn
Code Description Pile-up detection Mild Steel 20
R14-9020F-NOPBC c/w Fly Lead Proximity and motion detection Stainless Steel 15
Built-back control
R14-9020F-NOPBP c/w M.Plug Detection of missing tops or crowns on bottling lines Aluminium 8

23 RHE
CAPACITIVE SENSORS IP67
Diameter M12 M18 M30 1,5 BSP
Flush
Surface
Image

Specifications
Sensing Distance 4mm 8mm 8mm 15mm 20mm 30mm 20mm
Supply Voltage 10..30VDC 10..30VDC 10..30VDC 20-250VAC 50160Hz 10-60VDC
Current Consumption <9 mA <9 mA <9 mA 2.5 mA 10 mA
Output Current 200 mA 200 mA 200 mA 400 mA (min: 10mA) 400 mA
Voltage Drop 2 V @ 200 mA 2 V @ 200 mA 2 V @ 200 mA 2 V @ 200 mA 2 V @ 200 mA
Adjustment Multi-turn Pot Multi-turn Pot Multi-turn Pot Multi-turn Pot Multi-turn Pot
Switching Frequency 100 Hz 100 Hz 100 Hz 10 Hz 80 Hz
Operating Temp. -25 to + 70 -25 to + 70 -25 to + 70 -10 to + 65 -10 to + 65
Hysteresis <4% <4% <4% <5% <5%
Cable Length 2 meters, PVC 2 meters, PVC 2 meters, PVC Terminal Terminal
Cable Section 3 wire 2 wire or 3 wire 2 wire or 3 wire Connection Connection
Housing Material Nickel Plated Brass Nickel Plated Brass Nickel Plated Brass PVC PVC
Dimensions NAMUR

Code: RC0-4020S-NCPBT

AC 2-Wire: 0.4A fuse protection required

Code: RC1-4020S-NOPBT
-NCPBT

DC PNP 3-Wire

Code Code: RC4-4020S-NOPBT


-NCPBT
DC Sensors Flush Surface Flush Surface Flush Surface
PNP NO, Cable CS4-1204F-NOMTC CS4-1208S-NOMTC CS4-1808F-NOMTC CS4-1815S-NOMTC CS4-3020F-NOMTC CS4-3030S-NOMTC DC NPN 3-Wire
PNP NC, Cable CS4-1204F-NCMTC CS4-1208S-NCMTC CS4-1808F-NCMTC CS4-1815S-NCMTC CS4-3020F-NCMTC CS4-3030S-NCMTC
NPN NO, Cable CS5-1204F-NOMTC CS5-1208S-NOMTC CS5-1808F-NOMTC CS5-1815S-NOMTC CS5-3020F-NOMTC CS5-3030S-NOMTC
Code: RC5-4020S-NOPBT
NPN NC, Cable CS5-1204F-NCMTC CS5-1208S-NCMTC CS5-1808F-NCMTC CS5-1815S-NCMTC CS5-3020F-NCMTC CS5-3030S-NCMTC -NCPBT
PNP NO, Plug CS4-1204F-NOMTP CS4-1208S-NOMTP CS4-1808F-NOMTP CS4-1815S-NOMTP CS4-3020F-NOMTP CS4-3030S-NOMTP NAMUR
Requires a suitable control module to
PNP NC, Plug CS4-1204F-NCMTP CS4-1208S-NCMTP CS4-1808F-NCMTP CS4-1815S-NCMTP CS4-3020F-NCMTP CS4-3030S-NCMTP operate
2-Wire AC
NPN NO, Plug CS5-1204F-NOMTP CS5-1208S-NOMTP CS5-1808F-NOMTP CS5-1815S-NOMTP CS5-3020F-NOMTP CS5-3030S-NOMTP Supply Voltage: 20 to 250VAC, 50/60Hz
NPN NC, Plug CS5-1204F-NCMTP CS5-1208S-NCMTP CS5-1808F-NCMTP CS5-1815S-NCMTP CS5-3020F-NCMTP CS5-3030S-NCMTP Minimum Load Current: 10mA
Continuous Load Current: 400mA
AC Sensors Off-state Quiescent Current:
2,5mA at 250V AC
2-Wire NO Cable 20-250VAC - - CS1-1808F-NOMTC CS1-1815S-NOMTC CS1-3020F-NOMTC CS1-3030S-NOMTC These sensors are not protected against
sustained over current fault conditions.
2-Wire NC Cable 20-250VAC - - CS1-1808F-NCMTC CS1-1815S-NCMTC CS1-3020F-NCMTC CS1-3030S-NCMTC The fitting of an external inline 0,4A fuse
is therefore advised.
DC Sensors are to be connected
AC 2 Wire to a DC power supply and can switch
Wiring Diagram
loads (e.g. Relays, solenoids, PLCs) directly.
Supply Voltage: 10 to 60V DC
Maximum Ripple: 10%
Maximum Load Current: 400mA
Quiescent Current: <10mA
Polarity Protection: Yes
Overload Protection: Yes
For Sensor Cables see Page 34 Short Circuit Protection: Yes

RHE 24
NAMUR INDUCTIVE & CAPACITIVE SENSORS IP68 (DIN 19234)
Diameter M12 M18 M30 M40
Flush
Surface
Image

Specifications
Sensing Distance 2mm 4mm 5mm 8mm 10mm 15mm 20mm 25mm
Supply Voltage 8,2 - 10VDC (via module) 8,2 - 10VDC (via module) 8,2 - 10VDC (via module) 8,2 - 10VDC (via module)
Current Consumption 2 mA 2 mA 2 mA 2 mA
Output Current 0,8mA Typical 0,8mA Typical 0,8mA Typical 0,8mA Typical
(Metal present)
Output Current 4mA Typical 4mA Typical 4mA Typical 4mA Typical
(Metal absent)
Switching Frequency 2000Hz 1000Hz 500Hz 500Hz
Operating Temp. -20 to +70 -20 to +70 -20 to +70 -20 to +70
Hysteresis 3 to 15% 3 to 15% 3 to 15% 3 to 15%
Cable Length 2m 2m 2m 2m
Cable Section 2 Wire 2 Wire 2 Wire 2 Wire
Housing Material Aluminium Aluminium Aluminium Aluminium
Dimensions

Ex ia, Gr 2C, T6

NAMUR (To DIN 19234)


Code Flush Surface Flush Surface Flush Surface Flush Surface
NAMUR NC, Cable RI0-1202F-NCMTC RI0-1204S-NCMTC RI0-1805F-NCMTC RI0-1808S-NCMTC RI0-3010F-NCMTC RI0-3015S-NCMTC RI0-4020F-NCMTC RI0-4025S-NCMTC
NAMUR NC, Plug - - RI0-1805F-NCMTP RI0-1808S-NCMTP - - - -

For M12 Connector, Cable & Terminal DC Sensors

Capacitive
NAMUR sensors
M30 also available Flush Surface
NC, Metal, Cable RC0-3010F-NCMTC RC0-3020S-NCMTC
NC, Metal, Plug RC0-3010F-NCMTP RC0-3020S-NCMTP
Wiring Diagram
Ex ia, Gr T6 NAMUR sensors require a
suitably approved control module to operate
Code Description in intrinsically safe areas. (Please request
more information)
ST-02 PNP (sourcing) and NPN (sinking) Testing
M12-5-Pin Plug Input
NAMUR sensors require a suitable Slimline
Terminal Inputs Control Module to operate
Two Output LED's
Battery Powered For Sensor Cables see Page 34

25 RHE
AC INDUCTIVE SENSORS IP68
Diameter M12 M18 M30 M40
Flush
Surface
Image

Specifications
Sensing Distance 2mm 4mm 5mm 8mm 10mm 15mm 20mm 25mm
Supply Voltage 20 - 250VAC 20 - 250VAC 20 - 250VAC 20 - 250VAC
Current Consumption 2 mA 2 mA 2 mA 2 mA
Output Current 400mA 400mA 400mA 400mA
Switching Frequency 10Hz 10Hz 10Hz 10Hz
Operating Temp. -20 to +70 -20 to +70 -20 to +70 -20 to +70
Hysteresis 3 to 15% 3 to 15% 3 to 15% 3 to 15%
Cable Length 2m 2m 2m 2m
Cable Section 2 Wire 2 Wire 2 Wire 2 Wire
Housing Material Aluminium Aluminium Aluminium Aluminium
Dimensions

Code Flush Surface Flush Surface Flush Surface Flush Surface


NO, Cable RI1-1202F-NOMTC RI1-1204S-NOMTC RI1-1805F-NOMTC RI1-1808S-NOMTC RI1-3010F-NOMTC RI1-3015S-NOMTC RI1-4020F-NOMTC RI1-4025S-NOMTC
NC, Cable RI1-1202F-NCMTC RI1-1204S-NCMTC RI1-1805F-NCMTC RI1-1808S-NCMTC RI1-3010F-NCMTC RI1-3015S-NCMTC RI1-4020F-NCMTC RI1-4025S-NCMTC
NO, Plug RI1-1202F-NOMTP RI1-1204S-NOMTP RI1-1805F-NOMTP RI1-1808S-NOMTP RI1-3010F-NOMTP RI1-3015S-NOMTP - -
NC, Plug RI1-1202F-NCMTP RI1-1204S-NCMTP RI1-1805F-NCMTP RI1-1808S-NCMTP RI1-3010F-NCMTP RI1-3015S-NCMTP - -
Wiring Diagrams

Cable Type: Plug Type:

For Sensor Cables see Page 34

RHE 26
DC INDUCTIVE SENSORS
Diameter M12 M18 M30 M40
Flush
Surface
Image

Specifications IP67 IP67 IP68 IP68


Sensing Distance 2mm 4mm 5mm 8mm 10mm 15mm 20mm 25mm
Supply Voltage 10...30VDC 10...30VDC 10...60VDC 10...60VDC
Current Consumption < 8 mA < 8 mA 10 mA 10 mA
Output Current 200 mA 200 mA 400 mA 400 mA
Voltage Drop < 1,5 V @ 200 mA < 1,5 V @ 200 mA 2V 2V
Switching Frequency 1000 Hz 500 Hz 300 Hz 500 Hz 100 Hz 500 Hz 1000 Hz 500 Hz
Operating Temp. -25 to +70 -25 to +70 -20 to +70 -20 to +70
Hysteresis 3 ...15% 3 ...15% 3 ...15% 3 ...15%
Cable length 2 meters, PVC 2 meters, PVC 2 meters, PVC 2 meters, PVC
Cable section 3 Wire 3 Wire 3 Wire, 4 Wire(NX) 3 Wire, 4 Wire(NX)
Housing Material Nickel Plated Brass Nickel Plated Brass Aluminium Aluminium
Dimensions

Cable L = 30 Cable L = 30 Cable L = 35 Cable L = 40


Plug L = 50 Plug L = 50 Plug L = 48 Plug L = 53
Code Flush Surface Flush Surface Flush Surface Flush Surface
PNP NO, Cable IS4-1202F-NOMTC IS4-1204S-NOMTC IS4-1805F-NOMTC IS4-1808S-NOMTC RI4-3010F-NOMTC RI4-3015S-NOMTC RI4-4020F-NOMTC RI4-4025S-NOMTC
PNP NC, Cable IS4-1202F-NCMTC IS4-1204S-NCMTC IS4-1805F-NCMTC IS4-1808S-NCMTC RI4-3010F-NCMTC RI4-3015S-NCMTC RI4-4020F-NCMTC RI4-4025S-NCMTC
PNP NO/NC, Cable - - - - RI4-3010F-NXMTC RI4-3015S-NXMTC RI4-4020F-NXMTC RI4-4025S-NXMTC
PNP NO, Plug IS4-1202F-NOMTP IS4-1204S-NOMTP IS4-1805F-NOMTP IS4-1808S-NOMTP RI4-3010F-NOMTP RI4-3015S-NOMTP - -
PNP NC, Plug IS4-1202F-NCMTP IS4-1204S-NCMTP IS4-1805F-NCMTP IS4-1808S-NCMTP RI4-3010F-NCMTP RI4-3015S-NCMTP - -
PNP NO/NC, Plug - - - - RI4-3010F-NXMTP RI4-3015S-NXMTP - -
NPN NO, Cable IS5-1202F-NOMTC IS5-1204S-NOMTC IS5-1805F-NOMTC IS5-1808S-NOMTC RI5-3010F-NOMTC RI5-3015S-NOMTC RI5-4020F-NOMTC RI5-4025S-NOMTC
NPN NC, Cable IS5-1202F-NCMTC IS5-1204S-NCMTC IS5-1805F-NCMTC IS5-1808S-NCMTC RI5-3010F-NCMTC RI5-3015S-NCMTC RI5-4020F-NCMTC RI5-4025S-NCMTC
NPN NO/NC, Cable - - - - RI5-3010F-NXMTC RI5-3015S-NXMTC RI5-4020F-NXMTC RI5-4025S-NXMTC
NPN NO, Plug IS5-1202F-NOMTP IS5-1204S-NOMTP IS5-1805F-NOMTP IS5-1808S-NOMTP RI5-3010F-NOMTP RI5-3015S-NOMTP - -
NPN NC, Plug IS5-1202F-NCMTP IS5-1204S-NCMTP IS5-1805F-NCMTP IS5-1808S-NCMTP RI5-3010F-NCMTP RI5-3015S-NCMTP - -
NPN NO/NC, Plug - - - - RI5-3010F-NXMTP RI5-3015S-NXMTP - -
Wiring Diagram

For Sensor Cables see Page 34

27 RHE
PHOTOELECTRIC SENSORS 50mm X 50mm IP65
Type Diffuse Polarized Reflective

Cubic Series Relay Output Relay Output


Intergrated Output LED

Specifications
Sensing Distance 300mm...2m 300mm...2m 0...6m 0..6m
Supply Voltage 10... 30 VDC 24...240VDC / VAC 10... 30 VDC 24...240VDC / VAC
Emission Infra Red LED 800nm Infra Red LED 800nm Infra Red LED 800mm Infra Red LED 800mm
Setting Sensitivity Trimmer Sensitivity Trimmer Sensitivity Trimmer Sensitivity Trimmer
Output PNP, NPN, NO, NC Relay, SPDT NO+NC PNP, NPN, NO, NC Relay, SPDT NO+NC
Programmable Programmable
Output Current 200mA 1A / 230 VAC 200mA 1A / 230 VAC
Current Consumption < 37mA < 2.2W < 37mA < 2.2W
Voltage Drop < 2V@ 200mA - < 2V@ 200mA -
Response Time < 1ms < 25ms < 1ms < 25ms
Switching Freq. 500 Hz 10 Hz 500 Hz 10 Hz
Operation Mode Dark or Light Dark or Light Dark or Light Dark or Light
Ingress Protection IP65 IP65 IP65 IP65
Housing Material ABS, Lens PMMA ABS, Lens PMMA ABS, Lens PMMA ABS, Lens PMMA
Operating Temp. -25...55 -25...55 -25...55 -25...55
Mounting Bracket Included Included Included Included
Dimensions

Code
PNP, NPN, NO, NC, Cable
OD50-D2PNCO/2P OD50-P6PNCO/2P
Programmable
PNP, NPN, NO, NC, Plug
OD50-D2PNCO/M12 OD50-P6PNCO/M12
Programmable
relay NC+NO, Cable OD50-D2ACO/2P OD50-P6ACO/2P
relay NO, Plug OD50-D2AO/M12 OD50-P6AO/M12
relay NC, Plug OD50-D2AC/M12 OD50-P6AC/M12
Wiring Diagram

4 Wire DC 5 Wire DC

RHE 28
PHOTOELECTRIC SENSORS IP67
Type Diffuse Polarized Reflective

M18 Flat
Intergrated Output LED

Specifications
Sensing Distance 0... 400mm 300mm 1400mm 1200mm
Supply Voltage 10... 30 VDC 10... 30 VDC 10... 30 VDC 10... 30 VDC
Setting Sensitivity Trimmer Sensitivity Trimmer Sensitivity Trimmer Sensitivity Trimmer
Output NO NC NO NC NO NC NO NC
Output Current 100mA 100mA 100mA 100mA
Current Consumption < 30mA < 30mA < 30mA < 30mA
Voltage Drop < 2V @100mA < 2V @100mA < 2V @100mA < 2V @100mA
Response Time < 1ms < 1ms < 1ms < 1ms
Switching Freq. 1000 Hz 1000 Hz 1000 Hz 1000 Hz
Operation Mode Dark or Light Dark or Light Dark or Light Dark or Light
Housing Material ABS, Lens PMMA ABS, Lens PMMA ABS, Lens PMMA ABS, Lens PMMA
Operating Temp. -25...55 -25...55 -25...55 -25...55
Mounting Bracket on request on request on request on request
Dimensions

Code
PNP, NO+NC Cable OD18FA-D04PSB/2P OD18FR-D03PSB/2P OD18FA-P014PSB/2P OD18FR-P012PSB/2P

NPN, NO+NC Cable OD18FA-D04NSB/2P OD18FR-D03NSB/2P OD18FA-P014NSB/2P OD18FR-P012NSB/2P

PNP, NO+NC Plug-in OD18FA-D04PSB/M12 OD18FR-D03PSB/M12 OD18FA-P014PSB/M12 OD18FR-P012PSB/M12

NPN, NO+NC Plug-in OD18FA-D04NSB/M12 OD18FR-D03NSB/M12 OD18FA-P014NSB/M12 OD18FR-P012NSB/M12


Wiring Diagram

29 RHE
PHOTOELECTRIC SENSORS
Type Through Beam Cubic 50x50 Through Beam M18

Cubic Series Relay Output IP67 IP67


Intergrated Output LED

Specifications
Sensing Distance 18m 18m 10m 9.5m
Supply Voltage 24...240VDC / VAC 10... 30 VDC 10... 30 VDC 10 - 30VDC
Emission Infra Red LED 800nm Infra Red LED 800nm Infra Red LED 800mm Infra Red LED 800mm
Setting Sensitivity Trimmer Sensitivity Trimmer Sensitivity Trimmer Sensitivity Trimmer
Output Relay, NO or NC PNP, NPN, NO, NC NO, NC NO, NC
(order option) Programmable
Output Current 1A / 230 VAC 200mA 100mA 100mA
Current Consumption < 2.2W < 37mA < 30mA < 30mA
Voltage Drop - < 2V@ 200mA < 2V@ 100mA <2V@100mA
Response Time < 25ms < 1ms < 1ms < 1ms
Switching Freq. 10 Hz 500 Hz 1000 Hz 1000 Hz
Operation Mode Dark or Light Dark or Light Dark or Light Dark or Light
Ingress Protection IP65 IP65 IP67 IP67
Housing Material ABS, Lens PMMA ABS, Lens PMMA ABS, Lens PMMA ABS, Lens PMMA
Operating Temp. -25...55 -25...55 -25...55 -25...55
Mounting Bracket Included Included
Dimensions

Code
Transmitters OD50-T18A/M12 OD50-T18D/M12 OD18FA-T10B/M12 OD18FR-T095B/M12
Receivers:
SPDT - -
Programmable Reciever - OD50-R18PNCO/M12
PNP, NO+NC Plug OD18FA-R10PSB/M12 * OD18FR-R095PSB/M12 *
NPN, NO+NC Plug OD18FA-R10NSB/M12 * OD18FR-R095NSB/M12 *
Relay NO, Plug OD50-R18AO/M12
Relay NC, Plug OD50-R18AC/M12
* For cable type change M12 to 2P e.g. OD18FA-R095PSB/2P

For Sensor Cables see Page 34

RHE 30
ACCESSORIES
Conductive Probe Kits Siren Modules Pressure Transmitter IP65
For use with liquid level relays Wail

PT1X*P**
Yelp Accuracy to better than 0.5%FS
(including linearity and repeatability)
Transducer rated at 50 million cycles
Metalwork made of Type 316
Code Description Code Description Stainless Steel
Protected against reverse voltage
CP2/C 2-Way 1m probe kit with coated rods ES/225/*/** Wail or Yelp
and overvoltage
CP3/C 3-Way 1m probe kit with coated rods 110VAC or 230VAC + 12VDC Protected against noise on the supply line
8 Wide supply range, 8 to 36VDC -
CP2/CX 2-Way head only
5Watt allows a wide range of load resistance
CP3/CX 3-Way head only
*Add sound to code: 1 = Wail, 2 = Yelp Transducer is temperature compensated
DD2 2-Way Probe Spacer **Add to code 115VAC or 230VAC by means of laser-trimmed resistors
DD3 3-Way Probe Spacer Operating temperature range from
Reflectors 0 to +85
EP1/C Spare 1m s/s Rod coated
Code R2 R5 Internal Trimpots for field calibration
EP1/U Spare 1m s/s Rod uncoated 63
55
EP1/EXT M4 Connecting Nut Brass
Head: Nylon, 1.5 BSP. 70C max.Using coated rods
improves resistance and prevents nuisance switching
83

caused by frothing or condensation


74
48

Mounting Brackets
for Proximity Sensors
Code R4 DAC100 GENERAL SPECIFICATIONS
Code Description 10 20 10
Output: 4 - 20mA
ST1218 Excitation: 8 - 36V DC
4.3

For M12 & M18


Accuracy (BFSL):< 0.5% FS
ST1830 For M18 & M30
Compensated Temp. Range: 0 to 85 C
100
92
61

Temperature error zero: < -0,02% FS / K


Temperature error span: < -0,01% FS / K
51.5 (0-70C)
Connectors and Cables Ingress protection: IP65
Burst pressure: 2.5 x FS (except when
Dimensions Cable Length* Code indicated)
Female connector and cable M12 Plug Wetted Parts/Connection: 316 Stainless
90 Version
4 Pin 4 Wire
3m CS-A2-02-G-03 steel, ceramic, Nitrile (Specify media
38.5 where Nitrile is not compatible)
5m CS-A2-02-G-05
WIRING CONNECTIONS
3 Pin 3 Wire 5m CS-A2-11-G-05 1 Red: + Us
24

2 Black: - Vs
Connector with no cable CS-A2-02-B-NC 3 Yellow: GND
Straight Version 3m CS-A1-02-G-03 * **
4 Pin 4 Wire Code Transducer Range Code Fitting
42.5 5m CS-A1-02-G-05 0010 1 Bar 02 1/4 NPT
0040 4 Bar 04 1/2 NPT
3 Pin 3 Wire 5m CS-A1-01-G-05 0060 6 Bar 12 1/4 BSP
14
12

0100 10 Bar 14 1/2 BSP


Connector with no cable CS-A1-02-B-NC 0160 16 Bar Other options available
Female connector and cable M8 Plug 0250 25 Bar
0400 40 Bar
3m CS-B1-02-G-03 1000 100 Bar
32 4 Pin 4 Wire
5m CS-B1-02-G-05 4000 400 Bar
3m CS-B1-01-G-03 Other options available
10

3 Pin 3 Wire PRODUCT TRANS

CS-B1-01-G-05
PRESSURE FITTING
5m RANGE DUCER
RANGE

*10m versions available on request PT1X * P **

31 RHE
PROCESS GAUGES
Type Stainless Steel Case Robust Liquid Filled Economic

Code
Connection
PBB-
* - ** - *** - **** - ***** PBG- -
* ** -
*** -
**** -
*****
For heavy duty services where vibration or
PBN-
* -
** -
*** -
**** -
*****
For non-corrosive liquids and gases on light
This gauge is ideally suited to most
A-Bottom Connection industrial applications where high accuracy shock of medium would cause excessive wear duty service in more corrosive environments.
D-Rear Connection and durability is required. Gauges are on a dry gauge or corrosive ambient Applications include coastal application for
available with either brass/bronze internals, conditions prevail. Applications include valve positioner and regulators, swimming
all stainless steel internals, or Manel hydraulic equipment, mining equipment and pool pumps and stationary irrigation systems.
Bourdan tube and socket with stainless irrigation.
steel movement.
Case Brush finish 304 SS, Bayonet Bezel 304 SS, Crimped Bezel Steel Black, Powder Coated
Internals Available with either Brass/Bronze, or SS Brass Brass
Range (Max) 6000 kPa 6000 kPa 6000 kPa
Temperature -25 to 60 -25 to 60 -25 to 60
Accuracy 100 1% @ FSD / 63 1.6% @FSD 1.6% @ FSD 1.6% @ FSD
Configuration
Thread
Code Fitting
02 1/4 NPT
04 1/2 NPT
12 1/4 BSP
14 1/2 BSP Conn. A
Add to code Conn. A + D A+D Conn. A + D A+D

A (Bottom) & D (Rear) A (Bottom) & D (Rear) A (Bottom) only


* Connection
** Add size (mm) 63 100 63 only 54 only

*** System material BB&SS BB BB


**** Thread size 02, 12 02, 04, 12, 14 02, 12 02, 12

***** Add pressure 100kPA, 160kPA, 250KPA, 400kPA, 600kPA, 1000kPA, 1600kPA, 2500kPA, 4000kPA, 6000kPA. Other ranges available on request.
Process Gauges Accessories
Steam Line Piping Valve Dairy Seals Chemical Seals Flanged Seals

NW40 NW50

Code U-TYPE Code VG ISOLATE Code NW40-* NW50-* XWD4-* NFD01-*


Isolation valves and Material Grade 316 SS 316 Stainless Steel Grade 316 SS
gauge cocks to isolate Max Pressurer 40 MPA 150 Mpa 150 Mpa
pressure from gauge.
Gauge Port 1/4", NPT or BSP 1/4" or 1/2", NPT or BSP 1/4" and 1/2", NPT
Equipped with a facility
to vent the gauge. Application Is used in health and Is used in applications Flanged seals, one for
Suitable for use with dairy application, can be where the process fluid continuous use for safety
Code PIGTAIL used for pulp/paper. (medium) is corrosive or concerns.
gases, liquids and
Steam line piping should vapours. For non-corrosive liquids viscous (could even Cleanout type for easy
be installed on all live Material - Brass and gases on light duty contain waste particles) cleaning with flushing
steam applications to service in more corrosive and could clog the connections available.
protect the gauge from environments. instruments internals.
the high temperatures
encountered. Thread Size *Add Thread Type to Code: *Add Thread Type to Code: *Add Thread Type to Code:
Available in either "pigtail 02, 12 02, 04,12,14 02, 04
or U-type configurations
for installation on horizontal
or vertical line respectively
Material - Steel.

RHE
RHE 32
HOUSING DIMENSIONAL DIAGRAMS
Slimline A-Line & Protector

Housing Colour: Base Grey / Cover: Blue Housing Colour: Beige


Housing Material: Polycarbonate Housing Material: Nylon 66

48x48 Timers Industrial Relays

Housing Colour: Beige Housing Colour: Clear


Housing Material: ABS/Polycarbonate Housing Material: ABS/Polycarbonate
Countaline

Housing Colour: Charcoal


Housing Material: ABS/Polycarbonate

33 RHE
SLIMLINE/A-LINE INTERNAL RELAY SPECIFICATION
Relay Specifications
Ambient Temperature Storage: -50C to +85C
Operation: -20C to +50C
Maximum ripple on DC Power Supply 10%
AC Supply Frequency 40 - 70Hz
Proctection Class VDE 0110 (group C 250V),
NFC 20040 IEC 0435
Isolation Group VDE 0435
Note: Modules with power supply voltages exceeding 250V do not comply with the above standards

Relay Specifications

RHE 34
AC/DC SFC RHOMBERG

5th Edition April 2016