BUILDING DATA
LENGTH OF THE BUILDING 46 meters
WIDTH OF THE BUILDING 32.5 meters
EAVE HEIGHT 12 meters
BAY SPACING 7.66 meters
8.14 4.27
5.29 1.42
7.12 7.12
LOAD
Y -4.99 CASE 5 4.99
LOAD
CASE 5
K1 K2 K3
1.00 1.01 1.00
H/W 0.37
DESIGN WIND VELOCITY 39.24 m/s L/W 1.42
WIND PRESSURE 0.930 kN/m
CLICK ON '+' ON THE LEFT TO VIEW ( STADD USER CAN COPY THE DETAILS SHOWN BELOW IN STADD EDITOR FO
* (+i) TRANSVERSE WIND PRESSURE
* GCPe (GCPe - GCPi) WIND LOAD
* LEFT WALL 0.700 0.50 x0.93x7.66= 3.56
* LEFT ROOF -0.943 -1.14 x0.93x7.66= -8.14
* RIGHT ROOF -0.400 -0.60 x0.93x7.66= -4.27
* RIGHT WALL -0.250 -0.45 x0.93x7.66= -3.21
*
* (-i) TRANSVERSE WIND SUCTION
* GCPe (GCPe - GCPi) WIND LOAD
* LEFT WALL 0.700 0.90 x0.93x7.66= 6.41
* LEFT ROOF -0.943 -0.74 x0.93x7.66= -5.29
* RIGHT ROOF -0.400 -0.20 x0.93x7.66= -1.42
* RIGHT WALL -0.250 -0.05 x0.93x7.66= -0.36
*
* (+i) LONGITUDINAL WIND PRESSURE
* GCPe (GCPe - GCPi) WIND LOAD
* LEFT WALL -0.500 -0.70 x0.93x7.66= -4.99
* LEFT ROOF -0.800 -1.00 x0.93x7.66= -7.12
* RIGHT ROOF -0.800 -1.00 x0.93x7.66= -7.12
* RIGHT WALL -0.500 -0.70 x0.93x7.66= -4.99
*
* (-i) LONGITUDINAL WIND SUCTION
* GCPe (GCPe - GCPi) WIND LOAD
ROOF SLOPE 1 : 10
WIND SPEED 39 m/s
TERRAIN CATEGORY 1
BUILDING CATEGORY C
4.27 8.14
1.42 5.29
4.27 4.27
LOAD
CASE 6
-2.14 2.14
INTERNAL PRESSURE CO-EFFICIENT
0.2
h/w0.5 GCpi
1<l/w1.5 -0.2
WIND LOAD
kN/m (pressure)
kN/m (suction)
kN/m (suction)
kN/m (suction)
WIND LOAD
kN/m (pressure)
kN/m (suction)
kN/m (suction)
kN/m (suction)
WIND LOAD
kN/m (suction)
kN/m (suction)
kN/m (suction)
kN/m (suction)
WIND LOAD
kN/m (suction)
kN/m (suction)
kN/m (suction)
kN/m (suction)
CALCULATION OF EXTERNAL PRESSURE COEEFFICIENT ON P
(AS PER IS-875 1987:PART 3 ;REAFFIRMED 2003)
= 5.71
h/w = 0.4
ROOF ANGLE WIND ANGLE = 0 deg.
E F G H
5.71 -0.943 -0.943 -0.400 -0.400
NOTE:
when wind acts in lateral direction of frame ( i.e 0 deg wind angle)
*E & F falls on windward side & has same co-efficients
*G & H falls on leeward side & has same co-efficients
when wind acts in longitudinal direction of frame ( i.e 90 deg wind angle)
*E & G has same coefficients
*F & H has same co-efficients
co-efficients for the local effects are not used for calculating
h (in meters) = 12