Manyyearsofexperienceworkingonhighprofileprojects,combinedwithindustryleadingexpertise,allows

AlwaysOnUPSSystemsCanadaInc.todesignandmanufacturethehighestqualityuninterruptiblepower
supplyandpowerconditioningproducts.AllAlwaysOndesignsincorporatethemostefficientandrobust
devicesandsystemcomponentstoprovidethehighestdegreeofprotectionpossibleforallcriticaland
emergencyequipmentinstallations.
AlwaysOntakesgreatprideinprovidingcompletesolutions.Thisincludesallmodesandlevelsofprotection
beingdesignedintoeachandeverysystemwebuild,eliminatingtheneedforadditionalequipmenttobeadded
toaddressthetotalsystemrequirements.Wedonotcobbletogetherstandardproductslikesomeofourlarger
competitorsdo,butinsteadprovideacustomizedengineeredsolutiontomeetcustomerneeds.Ensuring
protectionandpowerqualitythrougheverymodeofoperationrequirescoordinationbetweenallsystem
components.Thisincludessurgeprotectiondevices,inverters,batteries,batterychargers,bypasssystems,
transferswitchesandpowerdistributionunits.
EveryemployeeandmanageratAlwaysOntakesapersonalinteresttoensurethatallstagesofeachproduct
isdesigned,manufacturedandtestedtothehighestdegreeofqualitywithinourISO9001:2008certifiedfacility.
ThisQMScertification,alongwithournumeroussafetyapprovals(suchasourvariousUL,CSA,CCMC,BMEC,or
ABSlistedproducts),givesustheconfidencetosetusapartasoneoftheleadingUPSmanufacturersinthis
industry.
AlwaysOnproductsareputintoservicebymanyworldrenownedcompaniesanduserswhorelyonour
expertiseandthehighreliabilityofoursystemstoprotecttheircriticalinstallations.Theseincludeindustries
suchastheoil,gasandminingindustries,airplaneandothermanufacturingplants,hospitalsandoperating
rooms,railandmarinetransportationsystems,datacenters,army,navy,airforceandmilitaryinstallations,
nuclearandotherpowergeneratingplants,publicutilities,andemergencysystemsforbuildings.
Someofourcustomersinclude:Boeing,CanadianNaturalResourcesLtd.,SiemensUSA,GEEnergy,HuskyOil,
SherrittMines,ProtransCanadaLine,Beghelli,Stanpro,theDepartmentofNationalDefense,theUSNavy,New
BrunswickNuclearPower,L3Communications,FortisBC,theRCMP,BCHydro,andtheCanadianCoastGuard.

Wehopeyouwillvisitourwebsite:www.alwayson.comformoreinformation,orcallourinsidesalesand
engineeringsupportonourtollfreetelephonelines:18772592976(Salesext.451).

Or,youcanemailforsupportdepartments:sales@alwayson.com,engineering@alwayson.com

RobertS.Adria,President

Catalogueversion:AO2014052300
AlwaysOn UPSSystemsCanadaInc www.alwayson.com 2
Engineered Solutions
AlwaysOnUPSSystemsCanadaInc.isnotyourtypicalmanufacturer.Inadditiontoproviding
standardproduct,weprovideengineeredsolutionstofituniqueapplicationsandcustomer
requests.Someofoursolutionsareshownbelow.

Boeing - Moving assembly line crawler - 100kVA

Transportable modular power - Canadian military hospital - Afghanistan - 100kVA

John P. Tully - Canadian Coast Guard Canada Line - Rapid Transit - Vancouver, BC

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 3


Index
EngineeredSolutions Page 3
AlthoughAlwaysOnhasastandardproductoffering,wearemostrecognizedbyprovidingengineered
solutions.Fromsensitivetelecommunicationequipmenttooilrigconditions,wecanprovidesolutionsto
suittheneedsofyourenvironment.

NXSeriesthreephasedualconversiononline Page 6
AlwaysOnsNXSeriesaredualconversiontrueonlineUPSsystemswhichprovidetheattachedloads
withisolationfromtheutilityorgeneratorsupplyandaredesignedforallcriticalapplications.Thesecritical
loadsaresuppliedpowerfromtheinverter,whichisfedbythebatteries.TheNXSeriesisdesignedwitha
largeinputrangeandincorporatesanoutputisolationtransformer.TheseUPSsystemsareavailablefrom
10kVAto250kVAwiththreephaseinputandthreephaseorsinglephaseoutputwithmultiplevoltage
configurations.

N&TNSeriessinglephasedualconversiononline Page 14
AlwaysOnsN&TNSeriesaredualconversiontrueonlineUPSsystemsdesignedforcriticalapplications
whichprovidetheattachedloadswithisolationfromtheutilityorgeneratorsupply.Atalltimes,theloads
aresuppliedpowerfromtheinverter,whichisfedbythebatteries.Thewideinputrange(gen.mode)is
designedintothesesystemswhilemaintainingoutputatvariousvoltageandfrequencyconfigurations.The
singlephasesystemsareavailablefrom700VAto20kVA.

ExternalBypassSystems Page 20
AlwaysOnoffersaseparatecabinettoallowforcompleteremovaloftheUPSsystemfromtheload,
whilestillsupplyingtheloadwithconditionedpower.Thesesystemsarerecommendedformaintenance
purposestopreventaccidentalremovalofpowerfromtheloadsandtoallowforcompletepowerremoval
fromtheUPSsystemforsafetyconsiderations.

ABSMarineApprovedUnits Page 21
AlwaysOnhasafullcomplementlineofABSapprovedsystemsrangingfrom700VAto320kVA.Wehave
installationsonBCFerries(QueenofOakBay,QueenofCapilano),CoastGuardvessels(Tully,SirWilfred
Laurier),Transportvessels,NavyvesselsandDrillingPlatforms.

LSerieslineinteractivetruesinewaveoutput Page 22
AlwaysOnsLSeriesarelineinteractiveUPSsystemswithatruesinewaveoutputonallmodesof
operation.Theyareidealforcommercialandindustrialapplicationsandrangeinsizefrom800VAto3kVA.
AllLSeriessystemsprovidevoltageregulation,noise,surgeandspikeprotection,serialcommunication
interface,networkandmodemprotection,extendedruntimeoptionsandadditionalcommunication
interfaces.

LimousinIIcommercialprotection Page 25
AlwaysOnsLIMOUSINSeriesaretransformerbasedUPSswhichprovidelightning,surge,spike,transient
andnoiseprotectionandfeatureconstantAutomaticVoltageRegulation(AVR)andblackoutprotection.
Theyaredesignedforthehome/officeusertoprovidethemaximumprotectionatacompetitiveprice.

Monitoring&ControlSoftware Page 26
AlwaysOnoffersseveraldifferentcommunicationandconnectionoptionstomanageyourUPSthrough
localornetworkedconnections.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 4


Index
TTF/ILFisolatinglinefilter Page 27
TheAlwaysOnTTF/ILFcombinesaLowPassSeriesfilterwithatoroidalisolationtransformer.Thisunit
providesattenuationofbothnormalandcommonmodenoiseandeliminatesanytroublesomeconstant
voltagewhichmayexistbetweenneutralandgroundinsomeelectricalconfigurations.Itistotally
compatiblewithalloperatingloads,includinghighfrequencyswitchingpowersupplies.Itreestablishesthe
0voltsgroundreferencepointonthesecondary.

ESEsurgeprotectiondevices Page 28
TheAlwaysOnESESPDfilterisdesignedtoprotectyourpowergrid.Installedatthepowerpanel,it
providesprotectionagainstexternallyandinternallyproducedpoweraberrations,massiveimpulses,
lightninginducedeffectsandinterferenceassociatedwithlowfrequencyharmonicsandsituationscaused
byaccidentsand/orfailuresintheelectricalutilitysystem.Itistotallycompatiblewithalloperatingloads
includinghighfrequencypowersuppliesandconstantcurrentloadscontrolledbyelectronicswitches.

PLClowpassseriespowerfilter Page 30
AlwaysOnsPLCfiltersaredesignedtoprovidenoise,surge,spike,transientandoverloadprotectionto
PLCpowersuppliesandperipherals.Twodifferenttypesareavailable:AConlyandAC/DCwithdataline
protectiontoensurecleanoperationandtransfertoallI/Ointerfaces,peripheralsandpowersupplies.All
systemsincludeanonboardresettablebreaker,andathreecolourLEDforeasyoperationidentification
anddiagnostics.

NFCSeriesfrequencyconverters&voltageregulators Page 32
AlwaysOnsNFCSeriesFrequencyConvertersincorporateallthefeaturesofourdualconversiontrueon
lineUPSsystemsaswellastheabilitytolocktheoutputfrequencytothethreemajorstandards.Thedual
conversiontechnologyallowstheloadtobesuppliedwith50Hz,60Hz,or400Hz,independentoftheinput.
TheNFCSeriesisdesignedwithlargeinputrangeandincorporatesanisolationtransformer.TheseNFC
systemsareavailablefrom10kVAto250kVAwiththreephaseinputandthreephaseoutput.

Aurora&Borealiscentralinvertersystems(emergencylighting) Page 34
AlwaysOnELIsaredesignedforinstallationbetweenyourACpowersupply(utilityorgenerator)andyour
lightingequipment.Itprovidespowertoyourequipmentduringmajorpowereventssuchasblackoutsand
brownouts,overvoltageandundervoltageconditions.TheELIprovidesaconsistentsupplyofregulatedAC
powerduringthesepowerevents,allowingyoutoensuresafetyandlightingfortheperiodrequired.

GeniesmartUPSpowerdistributionsystem Page 40
TheGenieisdesignedtodistributeACpowerwhileprotectingthemultiplecriticalloadssuppliedbythe
UPS.TheGenieincorporatestheAlwaysOnSDBbreaker,whichisspecificallydesignedtoclearinless
than1cycle,eliminatingmultipleloadtrips.TheGeniereplacestherequiredretrofittingofstandardpanels
withfastblowfuses.Acommunicationoptionallowsforremotestatus.

ALWBatteries&BatteryBankUnits Page 41
OurALWbatteriesarespecificallydesignedforourUPSsystems.UsingofficialAlwaysOnbatteries
protectsyourUPSandallowsustoguaranteeourclaimedbackuptimes.Ourbatterycabinetshaveseveral
usefulfeaturestofacilitatesetupandbatterymaintenance.

UPSMaintenance Page 42
AlwaysOnsUPSsystemsaredesignedformaximumreliabilityandpeakperformance.Evenso,aregular
maintenanceprogramisnecessarytoidentifyandcorrectpotentialproblemsbeforetheycanoccur.This
helpstopreventunplannedandinopportunedowntimeandoutagesofcriticalsystems,morerapidly
addressesproblemsthatcanoccur,andevenextendsbatterylifespan.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 5


NX Series
NX31 & NX33
Three Phase In / Single or Three Phase Out
Dual Conversion On-Line UPS
Industrial / Commercial
TrueSineWaveOnLineUPS
AlwaysOnNXSeriesUPSsystemsaredesignedtoprovidereliable,cleanand
consistentpowertoallcriticalloadsandemergencyapplications.Powerreliabilityis
businessreliability.
TheNXSeriesUPSisadualconversion,online,threephasesystemforuseascentralized
powerprotectionanddistribution.ThedualconversionprocessconvertstheutilityAC
supplyintoDCpower,whichisusedtochargethebatteriesandsupplypowertothe
inverter.TheInvertertheninvertstheDCpowerbackintoahighquality,regulatedand
isolatedACpowersource.ThewideoperatingrangeoftheUPSsystemallowsitremainonline
withoutdischargingordepletingthebatterycapacity.Thismakesitfullycompatiblewithpoorqualityindustrial
electricalenvironments,aswellasunstablegenerators.
TheUPScontinuallymonitorsandprovidesconditioningtotheincomingelectricalpower,removingunder
voltagesandovervoltages,sagsandspikesandotherirregularitiesthatareinherentwithinindustrialpower
systems.TheNXSeriesUPSsystemsuppliesclean,consistentpowerattheratedvoltagewithalowdistortion
puresinewaveforyoursensitiveelectronicequipment.Blackouts,brownoutsandotherpowerinterruptions,
regardlessofduration,canbeprotectedagainstwithadditionalbatterycabinetstoprovidethenecessary
emergencypowertosafeguardyouroperation.
AlwaysOnprovidesatrulyisolatedoutputtoeliminatealltypesofpoweraberrationsaswellasCommonand
NormalModenoise,increasingthereliabilityandlifeoftheloadsconnected.
OurHighQualityControlStandardsareensuredbytestingatthecomponentlevel,boardlevel,functionlevel
andcompletedstagelevelasspecifiedbyourISO9001:2008certification.
RedundantApplicationsforthehigheststandardofreliability:Missioncriticalapplicationssuchashospital
operatingrooms,airportsecurity,oilprocessingandrefineries,andmarineemergencysystemsrequirethe
highestavailabilityofpower.AlwaysOnsuniqueIPROtechnologysetsthehigheststandardforpower
reliability,withtheIPRO1+1compatibleNXSeriesUPSs.Decentralizedbypass,redundantcontrolelectronics
andbatteriesprovidematchedloadsharingandrobustfaulttolerantoperations.

FeaturesandBenefits
FullGalvanicIsolation
FullGalvanicIsolationprovidesacompletelyisolatedandreferencedoutput.Thisisolationprotectionprovidesa
provensolutiontoproblemscreatedbyinducedvoltagesaffectingthecriticalloads.Sincetheoutputcircuitto
theloadiscompletelyisolatedandnonoiseinducedontheneutralcanpermeatetotheloads,systemsoperate
inamorereliablefashion.Also,thistypeofprotectionincreasesthelifespanofequipmentbyeliminatingnoise,
whichbreaksdowncomponents.

Modulardesign
Eachmajorcomponent(inverter,rectifierandstaticswitch)ontheNXSeriesareinstalledonslideoutmodules.
Thisallowsforquickrepair(meantimetorepairof<30minutes)andeasyfieldupgradeability.

Fullydigital
DSP(DigitalSignalProcessor)andflashmemoryarethetechnologycornerstonesofthenewageofpower
qualityandreliability.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 6


NX Series

HighEfficiency
ThankstoIGBTtechnology,theNXSeriesUPSshaveahighefficiency.This,combinedwithIPRO,resultsinthe
mostcostefficientandreliableUPSsolutionintheindustry.

Convenientfrontpaneldesign
TheLCDdisplayandcontrolswitchesareaccessiblethroughtheup,down,andenterswitchesbelowthefront
panelwindow.Alltheviewableparameterscanbereadwithoutopeningthefrontdoor.Theinverteron/off
switchisprotectedfromaccidentaloperationbybeinglocatedbehindthelockedfrontdoor.Theinvertercan
stillbeswitchedonandoffviathecontrolswitchesonthefrontpanel,butthisfeatureispasswordprotected.

UPSmonitoringandmanagementviaSNMPmodule(included)
DirectaccessofremoteUPSandactivemanagementofsinglemodulesinmultiunitconfigurationsarethekeys
toefficientandpredictablepowerqualitymanagement.TheSNMPClient/Agentstructure,directlink,orremote
connectionenablesanetworkmanagerorfacilityengineertopermanentlymonitorandcontrollocalorremote
AlwaysOnUPSsystemsandtheequipmentandprocessestheyprotect.
ArealtimegraphicaldisplayofcriticalUPSparametersandenvironmentinformationofmultipledecentralized
UPSs,aswellasstatisticaldataandeventlogfiles,areavailableoneverylocalcomputerdisplayandnetwork
managementsystemorontheInternet.Additionally,UPSstatusinformationchangescanbesenttosuchvaried
informationcarriersasSMS,networkmanagementsystems,emailorfax.

HighEfficiencyMode
Thehighefficiencyfunctionaddscosteffectiveness,maximizesefficiencyandreducespowerconsumption.
Alternatingbetweenbypassandonlinemodesisachievedautomaticallyandinaccordancewiththeconditions
oftheACsupplypower.Onlinemodemaybeusedduringtimesofintermittentpower,andbypassmodewhen
theutilityiswithinuserselectableparametersinordertoobtaingreatestefficiency.Irregularitiescanbe
detectedinlessthanasecond,andonlinemodereactivatedimmediately.

Extensionofbatterylife
BatteriesareacriticalpartofeveryUPSsolution,actingasthepowersupplyintheeventofanACpowerfailure.
Theyaresensitiveproductsthatneedtobehandledandmonitoredcontinuouslyandcarefullyinorderto
increasetheirlifetimeandpredictability.AlwaysOnincludessuperiorbatterymanagementwithintheentire
NXSeriesfamilyandisacomprehensivemanagementandmonitoringsystemthatpreventsbatteriesfrom
overcharginganddeepdischarging.TheNXSeriesfeaturesanosurprisesautomaticbatterytest,andboost
charging,whichequalizesrechargingofbatteries.

Protection
Shortcircuit,overtemperatureandovervoltageprotectionisbuiltintoprotecttheNXSeriesUPSagainstany
formofmisuse.Backfeedprotection,completeprotectioncircuitsandexcellentoverloadbehaviorprovide
outstandinguserprotectionandapplicationsecurityoneveryUPSsystem.Fullgalvanicisolationisalsoincluded
intheNXseries.

Extremelyflexible
TheNXSeriesUPSofferstailormadepowerprotectiontocomplywithyourindividualinstallationrequirements.
Optionsincludea6pulserectifier(insteadofthestandard12pulserectifier)forunitsunder80kVAandaSmart
Panel(SP).Inaddition,acomprehensivesoftwaresuitecanbeaddedformissioncontrolanddataprotection.

Formoreinformation,visitwww.alwayson.com

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 7


NX Series
Options
ExternalBypassSystem
AlwaysOnoffersanexternalATS(AutomaticTransferSwitch)whichisfullyprogrammableforautomatic
electronicoperation.Thiswillautomaticallyswitchtobypass(alternatesource)intheeventthereislossof
powerfromthesystemforanyreason.

IPRO(IsolatedParallelRedundantOperation)
Forthehigheststandardofreliability.Missioncriticalapplicationssuchashospitals,airports,oilindustries,
refineries,andmarinerequirethehighestavailabilityofpower.AlwaysOnuniqueIPROtechnologysetsthe
higheststandardforpowerreliability,andIPRO1+1compatibleNXSeriesUPSs.Decentralizedbypass,
redundantcontrolelectronicsandbatteriesofferperfectloadsharingandrobustfaulttolerantoperations.

Redundancy
WithIPRO,theNXSeriesUPSsarecontrolledinatruepeertopeerconfigurationwhereallcriticalelementsand
functions(includingbypass)beingredundant.TheIPRO1+1systemhasthebenefitofredundantcontrol
electronics,activeactivesystemmanagementandfaulttolerantoperation.Failureofonesystemcomponent
stillallowsredundancyonremainingcomponents,whichpermitsthecompletemaintenanceandrepairofone
UPSwhiletheotherUPSremainsonline.

RemoteLCDDisplayPanel
FullmonitoringandcontrolofmultipleUPSsfromacommonpanellocatedupto300Maway.

TopCableEntry
ModuleattachedtotherearoftheUPScabinettoallowforconvenienttopcabletermination.

EmergencyPowerOffSwitch
LocalorremotelocatedswitchtoactivateEPOfunction.

HarshEnvironmentProtection
SeveralNEMAandIngressProtection(IP)ratedoptions,aswellasseismicmountingbrackets,areavailable.

NX33swithIPRO NX33withBBU

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 8


NX Series
True Sine Wave On-Line UPS 10kVA250kVA
GeneralData
Topology TrueOnLine,DualConversion
NominaloutputatPF=0.8 kVA 10 15 20 30 40 50 60 80 100 120 160 250
100%load,
Overallefficiency % 90 90 90 90 90 90 90 90 90 90 90 90
0.8PF
Truegalvanicisolationfrominputtooutput YES
Audiblenoiselevel(at1m) db(A) <65at1m <70at1m
Operating UPS 0Cto40C(32Fto104F)
temperature
range Battery Optimum:20Cto25C(68Fto77F);highertemperaturesreducebatterylifeexpectancy
Relativehumidity 0%to95%,noncondensing
Type Indoor(NEMA1)[Dripshieldandskirtingincluded]
Enclosure Safety Internaldeadfrontconstruction
Cooling Forcedairvariablespeed
Rigging Suitableforhandlingbyforkliftoroverheadcrane(eyehooksavailable)
Mounting Castersandlevelingfeet[optionalseismicratedmountingavailable]
Installation Installation&maintenance
Frontaccessrequiredfornormalmaintenance
access
Conduitaccess Bottomentrystandard[optionaltopentry]
Standards UL1778,CSA107.3listed,CSA22.2No.60950,FCCClassA,[optionalABSorUL924available]

Rectifier
Configuration 12pulserectifier
Voltage 208/480/600,LLVac,3phase,4(or3)wire+ground(20%to15%withoutbatterydischarge)
Frequency 4565Hz
Input Powerfactor 0.8atfullload
Inrushcurrent Limitedbysoftstartcircuit
Powerwalkin 20seconds
Outputvoltagetolerance 1%
Output
DCripplevoltage 0.5%
CurrentTHD 12pulserectifier:9%

Battery
NominaloutputatF=0.8 kVA 10 15 20 30 40 50 60 80 100 120 160 250
Batterycompatibility Sealedleadacid[optionalNiCDorflooded]
Numberofcells 174cells
Voltagerange 295410Vdc
Floatvoltageat20C(68F) 392Vdc
Lowvoltagelevel 320Vdc
Minimumdischargevoltage 295Vdc
Boostchargevoltage 410Vdc
Maximumchargecurrent(ADC) 5 7.5 10 15 20 25 30 40 50 60 80 125
Rechargetimefor30minutebatteryto95%
10timesthedischargetime
capacity
Automaticandmanualbatterytest Standard
Specificationsaresubjecttochangewithoutnoticetoreflectupgradesandimprovementintechnology.

Formoreinformation,visitwww.alwayson.com

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 9


NX Series
Inverter
NominaloutputatPF=0.8 kVA 10 15 20 30 40 50 60 80 100 120 160 250
DCvoltageinputrange 295415Vdc
Nominaloutputvoltage 208/120or480/277or600/347,3phase,4wire+ground
Inverterbridge IGBTtechnologyandPulseWidthModulated
Outputisolationtransformer Standard
Outputpowerfactor 0.8
Frequencylockrange 50/60Hz,7%
Outputwaveform Truesinewave
Static 1%
Outputvoltage
Loadstep0%100%0% 3%,recoveringtowithin1%in1cycle
tolerance
Loadstep0%50%0% 2%,recoveringtowithin1%in1cycle
Outputvoltage 100%linearload <2%THDmaximum
distortion 100%nonlinearload <3%THDmaximum
Crestfactorcapability Greaterthan3:1
Phase
100%balancedload 120 1%
displacement
Outputfreq. Freerunning 50/60Hz,0.1%synchronizedwithutility
<110% Continuous
Overload
110125% 15minutes
capability(on
125150% 5minutes
inverter)
>150% 30seconds
Efficiency(100%load) 92% 92% 92% 92% 92% 92% 92% 92% 92% 92% 92% 92%

Bypass
Inputconfiguration Commontorectifier[optionaldualinput]
PrimaryComponents Fullloadratedstaticswitch,backfeedprotectionandinternalmaintenancebypass
Voltagerange 20%ofinputvoltage
Frequencyrange 4555Hz/5565Hz
Efficiency 98%
Invertertobypass 0ms
Transfertime
Bypasstoinverter 0ms
Overload 200%ofUPSrating 30seconds
capacity 400%ofUPSrating 1second
Shortcircuitcapability(onbypass) 1000%for3cycles(nonrepetitive)
Isolationtransformer YES

Externalinterface
Alarmcontacts 8predefinedcontacts(COM,BATL,BACKUP,BYPASS,SS,FAULT,OVL,INVON)
Ethernetcommunications SNMPadapter
Serialcommunication RS232&RS485
Inputsignals Emergencypoweroffcontactsprovided(optionalswitchavailable)

Interfacecontrolsandalarms
Activemimic RepresentstheoperationalstatusoftheUPS,withintegratedLED's
diagram andpowerflowindicators

Audiblealarm Audiblesignalactivewhenanyalarmconditionispresent

DisplayofUPSmeteringfunctions,eventhistoryandfault
LCD/LEDdisplay
conditions

Optionalfeatures
Marineapproval ABS(AmericanBureauofShipping)
Emergencylighting UL924,BMECandCCMC
Mountingoptions Seismicratedmounting(seismiccertificationavailable)
Dualinput Bypassandrectifierhaveseparateinputs
Warranty Extendedwarrantyandservicespackagesavailable
Redundantoperation A+BBusssystemandIPRO(IsolatedParallelRedundantOperation)
Remotestatuspanel Activemimicdiagramw/StopOperationandSummaryAlarms

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 10


NX Series
BackupTimes(BatteryBanks)
FullloadruntimecalculationsforNXSeriesUPSsystemsfrom8kW(10kVA)to128kW(160kVA).
4000W 8000W 12000W 16000W 24000W 32000W
Load
5000VA 10000VA 15000VA 20000VA 30000VA 40000VA

Model

BBUNX33D 22min 8min 4min


BBUNX33E 105min 40min 18min 13min 6min
BBUNX33KF 36min 23min 18min 10min 5min
BBUNX33KG 80min 48min 32min 17min 10min
BBUNX33KH 120min 76min 46min 28min 19min
BBUNX33KI 130min 81min 50min 24min
BBUNX33KJ 130min 80min 60min

40000W 48000W 64000W 80000W 96000W 128000W
Load
50000VA 60000VA 80000VA 100000VA 120000VA 160000VA

Model

BBUNX33KG 6min
BBUNX33KH 12min 10min
BBUNX33KI 21min 18min 12min 6min
BBUNX33KJ 33min 30min 18min 10min 6min
2xBBUNX33KI 66min 50min 24min 21min 18min
2xBBUNX33KJ 92min 80min 60min 33min 30min 17min
Specificationsaresubjecttochangewithoutnoticetoreflectupgradesandimprovementintechnology.
Formoreinformationordifferentruntimes,pleasecontactCUSTOMERSERVICEtollfreeat18772592976,ext.451.

NXSeriesUPSSingleLineDrawing

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 11


NX Series
SystemDimensions
Thestandardconfigurationspresentedareintendedonlytoillustratethegeneralsizeoftheenclosures.These
unitsareshippedasseparatecomponents.
Drawingsarenottoscale.

10to50kVAUPSSystem 60to160kVAUPSSystem 250kVAUPSSystem


550mm(21.7")W 1100mm(43.3")W 2240mm(88.2")W
812mm(32")D 812mm(32")D 812mm(32")D
1600mm(63")H 1626mm(64")H 1626mm(64")H
380710kg 8501600kg 2700kg

DBatteryCabinet EBatteryCabinet KSeriesBatteryCabinet


235mm(9.25")W 400mm(15.75")W 1314mm(51.5")W
546mm(21.5")D 682mm(26.75")D 850mm(33.5")D
552mm(21.75")H 1008mm(39.75")H 1945mm(76.5")H
117kg 511kg 8141764kg

Formoreinformation,visitwww.alwayson.com

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 12


NX Series
ModuleInteriorLayout

Plugin
Rectifier
Module

Plugin
Inverter
Module

NX33UPSwithBackupBatteryUnit(BBU)

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 13


N & TN11 Series
Single or Multiple Phase Input / Single or Split Phase Output
Dual Conversion On-Line UPS
Industrial / Commercial / Critical Loads

Description
ThisdualconversionUPSsystemconvertstheincomingACsupplytoDC.TheDCpowerisusedtochargethe
batteriesandsupplytheinverter.TheinvertertheninvertstheDCpowerintoACpowerthat,inturn,issupplied
totheload.ThisdualconversionisolatesthelinefromACsupplyandallowsforwideinputpowervariationson
bothfrequencyandvoltage.Systemsinsinglephaseoutputconfigurationsrangefrom700VAto20kVA.

Applications
Amongotherapplications,theNandTN11SeriescanbeappliedtoLANfileservers,personalcomputers,
networksandworkstations,AutomaticTellerMachines,telecommunications,laboratoryandmedical
equipment,testequipment,POSequipment,robotics,PLCs,securityandemergencysystemsandmilitary&
governmentapplications.

AdvancedFeatures
Featuresincludeutilityinputpowerfactorcorrection,selfdiagnosis,anLCDdisplay,astaticbypass,smartpower
sourcemonitoringandbatterymanagement,lightning,noiseandsurgeprotection,spikeandtransient
protection,coldstart/autorestart,auserselectablefrequency,ageneratormodeandintelligent
communicationsinterface.SNMPandAS400adaptersareavailablefornetworkmanagement.Userreplaceable
batteries,emergencypoweroffcontrol,anisolationtransformerandmaintenancebypassswitchesarestandard
ontheTN11Series.

CompleteProtection
TheNandTN11SeriesUPSsaredesignedwithcomprehensivespike,transientandsurgeprotection,which
preventsdestructivehardwaredamageandextendssystemlife.ThehighendEMI/RFIfilteringdesignprevents
electricalCommonandNormalModenoisefromaffectingcomputeroperation,dataorfiles,includingwhenthe
UPSisinBypassMode.

OperatingVoltagesAndFrequencies
TheNandTN11SeriesUPSsaredesignedtofunctionatwidevoltageandfrequencyvariations.Thiswideinput
rangemakesthesystemsidealforgeneratorandproblematicareaapplications.Alsoavailableisafrequency
converteroptionallowingtheusertoselecttheoutputfrequencyat50or60Hz.

SelfDiagnosisAndInformationIndicators
EachNandTN11SeriesUPSisequippedwithamicroprocessorthatperformsaselfdiagnosisonceamonthto
ensurecontinuousruntime.Themicroprocessorisabletoidentifyfailures,displaythefailureontheLCDdisplay
andsendaudioandvisualalarms(offsitemonitoring).

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 14


N & TN11 Series

ColdStart
ThisfeatureallowstheNandTN11SeriesUPSstobepoweredupwhentheutilityisnotpresent.

AutoRestart
ThisuserselectablefeatureallowstheUPStorestartautomaticallywhenutilitybecomesavailable,providedit
hasbeenshutdownduetoanextendedblackout.

SmartPowerSourceMonitoringAndBatteryManagement
Viamicroprocessorbasedelectronics,theNandTN11SeriesUPSsproduceastricttruesinewaveoutput
regardlessoftheinput.Italsocontrolstheonbatteryandlowbatteryshutdown,whichpreventsfulldischarge,
therebyextendingthebatteryperformanceandbatterylife.

HighEfficiencyMode
Thehighefficiencyfunctionaddscosteffectiveness,maximizesefficiencyandreducespowerconsumption.
Alternatingbetweenbypassandonlinemodesisachievedautomaticallyandinaccordancewiththeconditions
oftheACsupplypower.Onlinemodemaybeusedduringtimesofintermittentpower,andbypassmodewhen
theutilityiswithinuserselectableparametersinordertoobtaingreatestefficiency.Irregularitiescanbe
detectedinlessthanasecond,andonlinemodereactivatedimmediately.

IntelligentCommunicationInterface
EachNandTN11SeriesUPSisequippedwithaRS232anddrycontactinterfaceport,forwhichweprovide
variouspowerfulmanagementsoftwareprograms.Forthemorecomplexnetworkenvironment,wesupport
SimpleNetworkManagementProtocol(SNMP),AS400relaycontactsandotheroptions,byaddingaplugin
moduletotheaccessibilityslot.

RemoteShutdownandEmergencyStop
Featuresincluderemoteshutdownviacommunicationport,emergencystopviacontacts.Anoptionalpush
buttoncontrolisavailable.

OptionalExtendedRuntimes
Tomeetyourbackuptimerequirements,weofferincreasedbackuptimebysimplyaddingadditionalhot
pluggablebatterycabinet(s).

OptionalUSB
Availableattimeoforder.

OptionalExternalBypass
AllowstheUPStobecompletelyshutdownorevenremovedsothatmaintenancecanbeperformedsafely
withoutanydowntime.Availableattimeoforder.

Formoreinformation,visitwww.alwayson.com

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 15


N Series
Single Phase Input and Output
True Sine Wave On Line UPS 700VA3kVA
NSeries Modelnumber: GES701N GES102N GES152N GES202N GES302N
Maximumcapacity 700VA/490W 1000VA/700W 1500VA/1050W 2000VA/1400W 3000VA/2100W
General
UPCordercode 82543330100 82543330200 82543330300 82543330400 82543330500
Nominalvoltage 120Vac(optional220Vacavailable)
Voltagerange 60Vac/40%load,70Vac/70%load,80Vac/100%load144Vac
Bypassvoltage 10%,+10/15%,+15/20%(userselectable)
Input Phase Singlephase(LNG)
Frequencywindow 4565Hz(2%,5%,7%userselectable)
Synchronizationwindow 3Hz
Powerfactor 0.99
Outputvoltage 100/110/115/120/127Vac(userselectable)
Voltageregulation 2%
Frequencyregulation 0.25Hz(batteryorfreerunmode)
VoltagedistortionTHD <3%linearload,<5%nonlinearload
Maxcurrent@120Vac 5.8A 8.2A 12.4A 16.5A 24.7A
Transientresponse 4%(100%loadchange)
Output Overloadcapacity 125%for1min./150%for10sec
Crestfactor 3:1
Efficiency >98%(highefficiencymode)
Transfertime Zero
8x515R 8x515R
Outlets 6x515R 2x520R 2x520R,
1xL520R 1xL530R
Batterytype Sealedleadacid,maintenancefreeHotswappablecartridge
Quantity 2 3 3 6 6
Voltage 24Vdc 36Vdc 36Vdc 72Vdc 72Vdc
Battery Rechargetime <4hoursto90%recovery
Advancedbatterymanagement Autoselftest,temperaturecompensated3stagecharging,loaddependentdischarge
Backuptimefullload 9min 10min 8min 12min 8min
Extendedruntime Available
Outputshort YES
Abnormalvoltage YES
Abnormalfrequency YES
Protection
I/Onoiseprotection Common&normalnoisesuppression
I/Ospikeandtransient YES
Telephone/network RJ11/RJ45
Display LCD/LEDStatus,readingsandsetupparameters
Audiblealarms Onbattery,lowbattery,overload,fault
Interface
Communications RS232/drycontact/(optional:USB,SNMP,AS400)
EmergencypowerOFF YESVianormallyclosedcontact
Operatingtemperature 0C40C(32F104F)
Environment Humidity 095%(noncondensing)
Audiblenoise <40dBAat1meter
Safety UL1778,CSA107.3
Approval ULlisted,cULlisted,(optionalABS[AmericanBureauofShipping],seebelow)
Conformance Surge/transient IEEEC62.41CAT.A
EMI/RFI FCCPart15
Warranty Twoyearfactorywarranty(optionalextendablewarrantiesavailable)
WxDxHmm(in) 152x413x238(6"x16.3"x9.4") 225x410x358(8.9"x16.1"x14.1")
Physicaldata
Weightinkg(lbs) 12(26.4) 13(28.6) 17(37.4) 27(59.4) 33(72.6)
Model# GES701NR GES102NR GES152NR GES202NR GES302NR
Rackmount UPCordercode 82543330111 82543330202 82543330301 82543330403 82543330501
models WxDxHmm(in) 482x425x84(19"x16.7"x3.3")[2U] 484x635x84(19.1"x25"x3.3")[3U]
Weightinkg(lbs) 18(25.3) 20(44.1) 25(55) 28(61.7) 32(70.5)
Model# GES701NABS GES102NABS GES152NABS GES202NABS GES302NABS
UPCordercode 82543330112 82543330231 82543330318 82543330401 82543330509
Marinegrade 152x413x238
WxDxHmm(in) ConsultAlwaysOnformoreinformation
models (6.0"x16.3"x9.4")
Weightinkg(lbs) 20(44.1) 42(92.2) 47(103.5)
Approval ABS(AmericanBureauofShipping);ULandcULlisted
Specificationsaresubjecttochangewithoutnoticetoreflectupgradesandimprovementintechnology.
Industrialcontainersareavailable(NEMA12,NEMA4,etc);consultmanufacturer.
Externalwraparoundbypassmodulesareavailableforallmodels,permittingUPSmaintenancewithoutpowerinterruptiontotheload.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 16


N Series
BackupTimes(BatteryBanks)
Tomeetyourbackuptimerequirements,weofferincreasedbackuptimebysimplyaddingadditionalbattery
cabinets.Todeterminethebatterybankpartnumber,locatetheUPSmodelnumberandadditionalruntimeyou
wanttoaddfromthetablesbelow.Foralternateruntimeorruntimecalculations,pleasecontactourfactory.

350W 490W 700W 1050W 1400W 2100W


Load
500VA 700VA 1000VA 1500VA 2000VA 3000VA

Model UPCordercode

BBU701NA 82543360300 28min 17min
BBU701NB 82543360325 48min 33min

BBU102NA 82543362600 30min 25min 17min
BBU102NB 82543362610 50min 33min

BBU152NA 82543362700 30min 25min 17min 13min
BBU152NB 82543362710 50min 33min 25min
BBU152NC 82543362730 100min 60min 40min

BBU202NA 82543362800 30min 25min 18min
BBU202NB 82543362810 150min 100min 60min
BBU202NC 82543360365 100min

BBU302NA 82543362900 30min 25min 18min 14min
BBU302NB 82543362910 150min 100min 60min 40min
BBU302NC 82543362920 100min 60min

Model Cabinetstyle Dimensions(mm) Dimensions(in) Weight

BBU701NA CabinetS 170Wx450Dx225H 6.75"x17.7"x9" 20kg(44lbs)
BBU701NB CabinetS 170Wx450Dx225H 6.75"x17.7"x9" 26.5kg(58lbs)
BBU102NA CabinetS 170Wx450Dx225H 6.75"x17.7"x9" 23kg(51lbs)
BBU102NB CabinetS 170Wx450Dx225H 6.75"x17.7"x9" 33kg(73lbs)
BBU152NA CabinetS 170Wx450Dx225H 6.75"x17.7"x9" 23kg(51lbs)
BBU152NB CabinetS 170Wx450Dx225H 6.75"x17.7"x9" 33kg(73lbs)
BBU152NC CabinetB 260Wx540Dx740H 10.5"x21.25"x29" 49kg(108lbs)
BBU202NA CabinetS 170Wx450Dx225H 6.75"x17.7"x9" 33kg(73lbs)
BBU202NB CabinetB 260Wx540Dx740H 10.5"x21.25"x29" 84kg(185lbs)
BBU202NC CabinetB 260Wx540Dx740H 10.5"x21.25"x29" 120kg(264lbs)
BBU302NA CabinetS 170Wx450Dx225H 6.75"x17.7"x9" 33kg(73lbs)
BBU302NB CabinetB 260Wx540Dx740H 10.5"x21.25"x29" 84kg(185lbs)
BBU302NC CabinetB 260Wx540Dx740H 10.5"x21.25"x29" 120kg(264lbs)
Specificationsaresubjecttochangewithoutnoticetoreflectupgradesandimprovementintechnology.

Formoreinformationordifferentruntimes,pleasecontactCustomerServicetollfreeat18772592976,Ext.451.
Standard5yearproratedwarrantywith1yearreplacement.Extendedwarrantiesavailable.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 17


TN11 Series
Single Phase Input and Output (2 or 3 Wire)
TN11Series Modelnumber: GES602TN11 GES103TN11 GES153TN11 GES203TN11
Maximumcapacity 6kVA/4.2kW 10kVA/7kW 15kVA/10.5kW 20kVA/14kW
General
UPCordercode 82543340030 82543340200 82543340400 82543340500
Ratedvoltage(nominal) 208(or240Vac)
Voltagerange 160276Vac
Input Phase 1(2wire+ground)
Frequencyrange 4565Hz
Powerfactor 0.98
Voltage 120,120/240,110/220Vac(otherconfigurationsavailable)
Voltageregulation 2%
Phase 1(3wire+ground)(otherconfigurationsavailable)
Totalcurrent@240Vac 25A 41.7A 62.5A 83.3A
Frequencyaccuracy 50Hz/60Hz0.5Hz(autosensing)
THD <3%linearload,<5%rectifiedload
Loadpowerfactor 0.7
Output
Slewrate 1Hz/second
Transientresponse 4%(100%loadchange)
Overloadcapacity 105%150%pour10secondes
Crestfactor 3:1
Efficiency(ACAC) >85%
Transfertime 0ms
Outlets Hardwired(otherconfigurationsavailable)
Batterytype Sealedleadacidmaintenancefree
Battery Voltage 240Vdc
Rechargetime 58hours;recovery=90%,typically
Fullload >10min >4min >8min >4min
Backuppowertime
Halfload >25min >13min >19min >13min
Extendedruntime AvailableConsult"BatteryBanks"
Outputshort YES
Abnormalvoltage YES
Protection
I/Onoiseprotection Common&normalmodenoisesuppression
I/Ospike&transientprotection YES
Communication RS232/drycontact/(optionalSNMPorAS400)
Interface Display LEDsandLCDstatusdisplay
Audiblealarms Onbattery,lowbattery,overload,fault
Operatingtemperature 040C(32104F)
Environment Humidity 090%(noncondensing)
Audiblenoise 55dBAat1meterfromunit
Safety/Approvals UL1778,CSAC22.2,UL&cULlisted,ABS[AmericanBureauofShipping]
Safetyapproval EMI/RFI FCCClassA
Surge/Transient IEEEC62.41CAT.A
WxDxHmm
257x580x700 342x679x715 342x800x900
PhysicalData (in) (10.1x22.8x27.6) (13.5x26.7x28.2) (13.5x31.5x35.4)
Weightinkg(lbs) 114(251) 250(551) 255(562) 265(584)
Specificationsaresubjecttochangewithoutnoticetoreflectupgradesandimprovementsintechnology.
Othervoltagesandconfigurationsareavailable.Forordercodes,consultAlwaysOn.
Anexternalwraparoundbypassmoduleisavailableforallmodels,permittingUPSmaintenancewithoutpowerinterruptiontothe
load.
Industrialcontainersareavailable(NEMA12,NEMA4,etc);consultAlwaysOn.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 18


TN11 Series
BackupTimes(BatteryBanks)
Tomeetyourbackuptimerequirements,weofferincreasedbackuptimebysimplyaddingadditionalbattery
cabinets.Todeterminethebatterybankpartnumber,locatetheUPSmodelnumberandadditionalruntime
youwanttoaddfromthetablesbelow.Foralternateruntimeorruntimecalculations,pleasecontactour
factory.

6000VA 8000VA 10000VA 12000VA 15000VA 20000VA


Load
4200W 5600W 7000W 8400W 10500W 14000W
UPC Cabinet
60592 CabinetD 20min 16min 15min 11min
60600 CabinetE 50min 40min 30min 18min 12min 7min
60940 CabinetKA 60min 35min 30min 20min 15min 10min
60941 CabinetKB 120min 90min 65min 45min 33min 20min
60942 CabinetKC 170min 120min 90min 70min 50min 35min
60943 CabinetKD 280min 200min 150min 130min 90min 60min
60944 CabinetKE 410min 310min 260min 180min 130min 100min

UPC Cabinet Dimensions(WxDxH) Weight
60592 CabinetD 235x546x552mm,9.25x21.5x21.75 80kg(177lbs)
60600 CabinetE 400x682x1008mm,15.7x26.8x39.7 353kg(777lbs)
60940 CabinetKA 812x863x1945mm,32x34x76.6 611kg(1347lbs)
60941 CabinetKB 812x863x1945mm,32x34x76.6 740kg(1632lbs)
60942 CabinetKC 812x863x1945mm,32x34x76.6 867kg(1912lbs)
60943 CabinetKD 812x863x1945mm,32x34x76.6 1004kg(2214lbs)
90644 CabinetKE 812x863x1945mm,32x34x76.6 1259kg(2776lbs)
Specificationsaresubjecttochangewithoutnoticetoreflectupgradesandimprovementintechnology.



Formoreinformationordifferentruntimes,pleasecontactCUSTOMER
SERVICEtollfreeat18772592976,Ext.451.




Formoreinformation,visitwww.alwayson.com

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 19


NX, N & TN Series
ExternalBypassSystems

AseparatecabinettoallowforcompleteremovaloftheUPSsystemfromtheload,whilestillsupplyingtheload
withconditionedpower.AlwaysOn offersvarioussystemswhichincludeisolationtransformersfordifferent
voltageconfigurations,distributionpanels,electromechanicalinterlockprotectiontoensureproperoperation,
rotaryswitchoperationandtransientvoltagesurgesuppression.

Systemsaresuppliedinamatchingcabinetorwallmountedcabinet.Thesesystemsarerecommendedfor
maintenancepurposestopreventaccidentalremovalofpowerfromtheloadsandtoallowforcompletepower
removalfromtheUPSsystemforsafetyconsiderations.

AlwaysOnalsooffersanexternalATS(AutomaticTransferSwitch)whichisfullyprogrammableforautomatic
electronicoperation.Thiswillautomaticallyswitchtobypass(alternatesource)intheeventthereislossof
powerfromthesystemforanyreason.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 20


ABS Marine Approved Units

AlwaysOn hasafullcomplimentlineofABSapprovedsystemsranging
from700VAto250kVA.WehaveinstallationsonBCFerries,CanadianCoast
Guardvesselsacrossthecountry,Transportvessels,USNavyvesselsand
DrillingPlatforms.Wealsoofferbypasssystemsandextendedruntime
modules.Oursystemsprovidecompletepowerconditioningtoincrease
productreliabilityformarineequipment.

Features
DripShield:Theadditionofadripshieldensuresthatliquidsandotherdebris
donotenteryourUPSthroughthetopcoolingvents.
FloorMount:YourUPScanbesecuredtothefloor,preventingitfrommovingor
fallingduetothemovementofthevessel.

AvailableModels
ABSApprovalisavailableontheseUPSsystems:
NX31&NX33Series:ThreePhaseIn/SingleorThreePhaseOut,10kVA250kVA
TN11Series:SinglePhaseInput&Output,6kVA20kVA
NSeries:SinglePhaseInput&Output,700VA3kVA

ABS:WhoTheyAre
Fromitsfoundationin1862,promotingmaritimesafetyhasbeenthecorecommitmentoftheAmericanBureau
ofShipping(ABS).
Today,westrivetobethemostefficientproviderofmarineandoffshoreclassificationservices.Weare
achievingthatgoalthroughtheinnovativethinking,enthusiasmandprofessionalismofourstaff.
AtABS,settingstandardsofexcellenceinmarineandoffshoreclassificationismorethanamottoitistheway
weconductbusiness.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 21


L Series
Intelligent Line Interactive UPS
True Sine Wave
Communications / Industrial

Rack mount

Description
AlwaysOnsLSeriesarelineinteractiveUPSsystemswithatruesinewaveoutputinallmodes.These
systemsareidealforcommercialandlightindustrialapplicationsandrangeinsizefrom800VAto3kVA.All
systemsprovidevoltageregulation,aserialcommunicationinterface,networkandmodemprotection,
extendedruntimeoptionsandadditionalcommunicationinterfaces.
Applications
Amongotherapplications,theLSeriescanbeappliedtoLANfileservers,personalcomputers,networksand
workstations,AutomaticTellerMachines,telecommunicationsequipment,POSequipment,robotics,test
equipment,PLCs,securityandemergencysystemsandapplicationswhereadditionalruntimeorSNMPare
required.

AdvancedFeatures
SmartBuckandBoostLineConditioning:TheAlwaysOn transformerbased(AVR)builtinline
conditioningprovidesstablevoltagewhentheutilitysupplyfluctuates.
Lighting,Noise,SurgeandTransientProtection:TheLSeriesofferslightningandsurgeprotection,common
modeandnormalmodenoiseprotectionandLowPassSeriesfiltersontheinputandoutput.
NetworkandModemProtection:TheAlwaysOn highendmulticomponentdesignprovidesultimate
protectionandRJ11andRJ45connectivity.
IntelligentCommunicationsInterface:RS232ordrycontactinterfaceportsactasthecommunicationlink
betweenthecomputerandtheUPS.Variousmanagementsoftwareisavailable.
ColdStart:ThecoldstartfunctionallowsstartfrombatterywhenACisnotpresent.
AutoRestart:ThisfeatureallowstheUPStorestartautomaticallywhentheutilitybecomesavailable,provided
theUPShasbeenshutdownduetoanextendedblackout.
AutoFrequencyDetection:Theautomaticfrequencysensingfunctionwillsynchronizetheinputandoutput
frequency.
BatteryReplacement:Userreplaceablebattery.
SNMPAdapter:AnoptionalSNMPadapterallowsyournetworktoeasilymanagetheUPS,includingremote
controlandstatusmonitoring.
ChargingCurrentWithLowRippleandLowHarmonicsAcontrolcircuitisusedtoprovideastrictsinewave
withlowrippleandlittleharmonicdistortionfromthechargingcurrent.
ValueAdded:PowerManagementandShutdownSoftware,CommunicationCable,PowerCable.
USBOption:Availableattimeoforder.
ExtendedRuntimeOptions:Additionalbatterybanksareavailableforallmodels.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 22


L Series

LSeries Model GES801L GES102L GES152L GES202L GES302L


Maximumcapacity 800VA/520W 1kVA/650W 1.5kVA/975W 2kVA/1300W 3kVA/1950W
General
UPCordercode 82543322100 82543322200 82543322300 82543322400 82543322500
Nominalvoltage 120Vac
Input Voltagerange 90150Vac
Frequencyrange 4565Hz
Nominalvoltage 120Vac
Autovoltageregulation +15%for90109Vac;15%for130150Vac
Current 6.6A 8.33A 11.65A 16.6A 25A
Frequency 50Hz/60Hz(Autodetected)
Output Powerfactor 0.51.0
Waveform(onbattery) Truesinewave
Loadcrestfactor 3:1(onbattery)
Transfertime 24ms(synchronized)
Outlets(515R) 4 6 4+Hardwired
Batterytype Sealedleadacidmaintenancefree
Quantity 2 2 3 4 4x2
Battery
Voltage 24Vdc 36Vdc 48Vdc
Rechargetime 24hours;recovery=90%,typically
Backuppower Fullload 8min 7min 7min 7min 8min
time Halfload 20min 17min 25min 25min 25min
Extendedrun
Available
time
Outputshort YES
Abnormalvoltage YES
Protection Modemornetwork Singleline(2wireRJ11)/Network(UTP,RJ45)compatiblejacks
I/Onoiseprotection Commonandnormalmodenoisesuppression
I/Ospike&transientprotection YES
Communication RS232/Drycontact/(optionalSNMP)
Interface LEDdisplay Normal/backup/lowbattery/fault/checkbattery/buck/boost
Audiblealarms Onbattery,lowbattery,overload,fault
Operatingtemperature 040C(32104F)
Environment Humidity 095%(noncondensing)
Audiblenoise 40dBAat1meterfromunit
Safety UL1778,CSAC22.2
Safetyapproval EMI/RFI FCCClassB
Surge/Transient IEEEC62.41CAT.A
UPSWxDxH 140x436x210(5.5x17.2x8.3) 168x436x225(6.6x17.2x8.9)
Externalbatterybank(if 168x570x225mm
Internalbatteries
Physicaldata applicable) (6.6x22.4x8.9)
46(101.4)(including
Weightinkg(lbs) 14.5(32) 15(33) 25(55.1) 30(66.1)
batterybank)
Model# GES801LR GES102LR GES152LR GES202LR GES302LR
UPCordercode 82543322105 82543322201 82543322301 82543322401 82543322501
Rackmount
models 555x438x102[2U] 438x378x130[3U] 483x560x175
WxDxHmm(in)
(21.9x17.2x4) (19x14.9x5.1) (19x15x7)[4U]
Weightinkg(lbs) 18(35.3) 20(44) 26.1(57.5) 28.4(62.6) 46.4(102.3)
Specificationsaresubjecttochangewithoutnoticetoreflectupgradesandimprovementsintechnology.

Additionalbatterybanksareavailableforallmodels.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 23


L Series
BackupTimes(BatteryBanks)
Tomeetyourbackuptimerequirements,weofferincreasedbackuptimebysimplyaddingadditionalbattery
cabinets.Todeterminethebatterybankpartnumber,locatetheUPSmodelnumberandruntimeyouwantin
thetablesbelow.Foradditionalruntimeorforruntimecalculations,pleasecontactourfactory.
350W 490W 700W 1050W 1400W 2100W
Load
500VA 700VA 1000VA 1500VA 2000VA 3000VA
Model UPCordercode
BBU801LA 82543360000 42min 33min
BBU801LB 82543360025 70min 45min

BBU102LA 82543360005 42min 33min 20min
BBU102LB 82543360030 70min 45min 30min

BBU152LA 82543360010 30min 25min 17min 13min
BBU152LB 82543360035 90min 55min 40min

BBU202LA 82543362300 72min 42min 30min
BBU202LB 82543360040 90min 50min

BBU302LA 82543362400 50min 40min 27min 18min
BBU302LB 82543360045 90min 50min 40min

Model CabinetStyle Dimensions(mm) Dimensions(in) Weight

BBU801LA CabinetS 170Wx450Dx225H 6.75"x17.7"x9" 26.5kg(58lbs)
BBU801LB CabinetS 170Wx450Dx225H 6.75"x17.7"x9" 33kg(73lbs)
BBU102LA CabinetS 170Wx450Dx225H 6.75"x17.7"x9" 26.5kg(58lbs)
BBU102LB CabinetS 170Wx450Dx225H 6.75"x17.7"x9" 33kg(73lbs)
BBU152LA CabinetS 170Wx450Dx225H 6.75"x17.7"x9" 23kg(51lbs)
BBU152LB CabinetB 260Wx540Dx740H 10.5"x21.25"x29" 49kg(108lbs)
BBU202LA CabinetB 260Wx540Dx740H 10.5"x21.25"x29" 39.5kg(87lbs)
BBU202LB CabinetB 260Wx540Dx740H 10.5"x21.25"x29" 61kg(134lbs)
BBU302LA CabinetB 260Wx540Dx740H 10.5"x21.25"x29" 37kg(81lbs)
BBU302LB CabinetB 260Wx540Dx740H 10.5"x21.25"x29" 61kg(134lbs)
Specificationsaresubjecttochangewithoutnoticetoreflectupgradesandimprovementsintechnology.

Formoreinformationordifferentruntimes,pleasecontactCustomerService
tollfreeat18772592976,Ext.451.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 24


Limousin II & The Bull
Home / Office / Commercial
LimousinII
Capacity 600VA/360W
General
UPCordercode 82543300111
Voltage 120Vnominal,(220Voption),25%
Input Frequency 50or60Hz10%(autosensing)
Inputsocket (1)IEC320
Voltage(onbattery) 120Vacnominal15%,simulatedsinewave
Frequency(onbattery) 50or60Hz,0.5Hz
Autovoltageregulation 10%ofnominal
Output
Waveformonbattery PulseWidthModulated(PWM)
Transfertime 4milliseconds,includingdetection
Receptacles (3)NEMA515R(120V)
TheLimousinIIisatransformerbasedUPS Spikeprotection 480joules,2ms
Protection&
thatprovideslightning,surge,transient, Filtering
Overloadprotection 110%for60secondsand130%for3seconds
andnoiseprotection.TheLimousinII Shortcircuit Fuseprotectionorimmediateshutdown
SeriesprovidesforconstantAutomatic Type Sealed,maintenancefreeleadacid
VoltageRegulation(AVR)andblackout Battery Typicalrechargetime 6hours(to90%offullcapacity)
protection.Itisdesignedforthehome/ Backuptime(fullload) 1030minutes

officeusertoprovidethemaximum Communications RS232

protectionatacompetitiveprice.A Interface LEDdisplay Normal/Backup/Overload


Audiblealarms Onbattery/Lowbattery/Overload
shutdown/controlsoftwarepackage,
Temperaturerange 040C(32104F)
communicationcableandtelephone/
Environment Humidity 095%(noncondensing)
networkprotectionareallavailablewith
Audiblenoise <40dBA(1meterfromsurface)
theLimousinII.
Safety cUL,UL1778,CSAC22.2
Safety
EMI/RF FCCPart15ClassB
Backview approval
Surge/Transient IEEEC62.41CAT.A
Netweightkg(lbs) 6.2(13.6)
Physicaldata Shippingweightkg(lbs) 6.7(14.9)
WxDxH(mm) 97x320x135
Specificationsaresubjecttochangewithoutnoticetoreflectupgradesandimprovementintechnology.

Singlelinedrawing

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 25


Power Management / Shutdown Software
UPSmonPlusdataandsoftwareprotection UPSmonPlusNetworkdataandnetwork
UPSmonPluspreventsyourcomputerfromcrashing softwareprotection
duringapowerfailure.IftheUPSsbatteryrunslow,in UPSmonPlusNetworkletsyoumonitorandmanage
thecaseofpowerfailure,UPSmonPluswilldetectthis multipleUPSsthroughyourTCP/IPnetworkfroma
andperformanorderlyshutdownofyourcomputer centrallocation.UsingyournetworkUPSmonPlus
beforethebatteryrunsout.Theautoshutofffeature Networkcanautoshutdownanunlimitednumberof
isalsousedtoperformscheduledshutdownand computersintheeventofapowerfailure.Theemail
startupofyourcomputerduringnormaloperations. andpagerfeaturescannotifyyouofapowerevent.
Withtheuseofyourcomputermodem,UPSmonPlus TheRedundantUPSmonitoringfeaturepermitstwo
cansendaneventcodetoyourpagertonotifyyouof ormoreredundantUPSstobemonitored.Ifone
apowerrelatedeventonyoursystem.Adatarecorder redundantUPSfailsoristakenofflinefor
isalsofeaturedthatrecordspowerdatainagraphic maintenance,UPSmonPlusNetworkstillmonitors
formtofacilitateanalysisofpowerqualityconditions. thebackupUPSandprovidesautoshutdown
Communications:RS232BiDirectional protectioninthecaseofapowerfailure.
Communications:RS232BiDirectionalandTCP/IP

MainUPS
management
screen

UPSpowermanagement
MainUPSmonsoftwarescreen scheduler
IndividualUPSs
statuscanalso
beviewed

ActivityMonitoringSoftwareReportScreens
Powerqualitydata
Pagingsetupscreen analysis Setactionsto
triggeronpower
events

.NetPowerSNMPAdapterintegratedintelligent
powermanagement(IIPM)
TheIIPMpackagesarecomprisedoftheSNMPAgent,
anSNMPadapterandonEvent.Theseareavailableto
efficientlycontrolandmanagetheGESseriesUPSs.The
excellentnetworkmanagementfeatureletsyoueasily
manageovertheInternet/IntranetusingTCP/IPand
Ethernet.
IIPMfeaturesremotemonitoringandcontrolviaaTCP/
IPnetworkandprovidesahierarchicalarchitectureto
manageyourUPSs.Italsofeaturesnotificationviae
mail,pager,audiblealarmorbroadcastandgraceful
graphicsformonitoringanddisplayingtherealtime
statusofyourUPS.IIPMalsoprovidesremote
shutdown,filesavingandpasswordprotection.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 26


TTF/ILF-12015
Isolating Line Filter
TheAlwaysOn TTF/ILF(ToroidalIsolatingLineFilter)combinesalowpassseriesfilterwithatoroidalisolation
transformer.TheTTF/ILFprovidesfortotalprotectionagainstallpoweraberrationsandeliminatesany
troublesomeconstantvoltageswhichmayexistbetweenneutralandgroundinsomeelectricalconfigurations.It
istotallycompatiblewithalloperatingloadsincludinghighfrequencyswitchingpowersupplies.
TheTTF/ILFcorrectsgroundfaultproblemsandeliminatesneutralvoltagesbyreestablishingthezerovolt
groundreferencepoint.Itprovidesexcellentnoiseprotection,eliminatingproblemscausedbynormalmodeand
commonmodenoise,aswellasotherelectricalaberrationssuchas:transients,spikes,surges,harmonicsand
lightninginducedvoltages.
Applications
Computers,LaserPrinters,Copiers,PointofSaleTerminals,MedicalInstruments,PLCs,ProcessInstruments,
CAD/CAM/CIM&Robotics.
ProtectsFrom:
ReversePolarity,Spikes,Surges,Transients,RFI/EMIInterference,Common/NormalModeNoise,Direct/Indirect
LightningEffects,andVoltagebetweenNeutralandGround.
Specifications
TTF/ILF-12015:
Frequency 50/60Hz 120Vac 15A Isolating Line Filter
Voltage Upto240V;1;Wye UPC Order Code: 825433 00800
Amperage 15A@120V,7A@220/240V TTF/ILF-22007:
VArating 1800VAmaximum 220Vac 7A Isolating Line Filter
UPC Order Code: 825433 00850
Protectionmodes Normalmode(LN),Commonmode(LG,NG)
Technology Dualhybridseriesfilter/Toroidalisolationtransformer
Insertionloss Nominal75dB,MilStd220A@100kHz;Commonmode120dB
Bandwidth Normalmode:10100kHz;Commonmode:DCto100mHz
Responsetime Instantaneous
Standards 15A,120Vac
Totalpeaksurgecurrent 26000A
Joules Upto600Joules
Leakagecurrent Nominal<250mA(<90mAhospitalgrade)
Operatinghumidity 097%(noncondensing)
Operatingtemperature 0C40C
Bypassmode(TTF/ILF12015BPonly) Alloutputsarepoweredviautilitypower
Warranty 5year
Dimensions 300x355x153mm(12"x14"x6")
Weight 20kg(44lbs)approximately
Wallmount Standard(towermodelavailable)

Specifications are subject to change without notice to reflect upgrades and improvements in technology.

Someoptionalfeaturesthatcanbeaddedarethemanualbypassswitchoranautomaticbypassswitch.
ThemanualbypassswitchwilltransfertheloadfromTTF/ILFsuppliedpowertoafilteredandisolatedACUtilityuponuser
operatedswitching.ThiswillallowforremovaloftheTTF/ILFsystemwithoutpoweringdownorexposingyourcriticalloads.
TheautomaticbypassswitchwillautomaticallytransfertheloadfromTTF/ILFsuppliedpowerintheeventofapremature
shutdownforwhateverreasonwithoutpoweringdownyourcriticalloads.
Surge/Transient Suppression: ANSI/IEEE C62.41-1992 - REV.2 (Surge Test) TYPICAL: 120V Filter

Input: LL LN LG NG
CategoryA3Ringwave100kHz6000V200A
Output(V) N/A 45V 47V 41V

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 27


Electrical Service Entrance
Surge Protection Device

TheAlwaysOn ESESPDfilterisdesignedtoprotect,atthepowerpanel,against
externallyandinternallyproducedpoweraberrations,massiveimpulses,lightninginduced
effectsandinterferenceassociatedwithlowfrequencyharmonicsandsituationscaused
byaccidentsand/orfailuresintheelectricalutilitysystem.Itisalsototallycompatiblewith
alloperatingloads,includinghighfrequencypowersuppliesandconstantcurrentloads
controlledbyelectronicswitches.

Applications
ElectricalServiceEntrancefiltersprotecttheelectronicandelectricalequipmentinthebuildingbysupplying
powerprotectionatthemainandsubpanellocations.
Protection
OurESEsofferhighendprotectionforindustrialandcommercialenvironmentsandourspecificallydesigned
andtunedcircuitryprovidesprotectionagainstallpotentiallydangerouselectricalaberrations.Theyeliminate
andattenuatetosafelevelscommonandnormalmodenoise,massivesurgeimpulses,indirectlightningstrikes
andtheireffects,interferenceassociatedwithlowfrequencyharmonics,
spikesandtransients,aswellasproblemsassociatedwithelectricalutility
failurescausedbyaccidents,storms,etc.
Electricalandelectronicequipmentcreatetheirownpoweraberrations,
whichcreatesproblemsforotherloadsandequipmentdownstream.
Theseaberrationswilltraveldownthepowerbustothepowerpanels,
wheretheypropagatetootherloadsviaotherbranchcircuits.
ByinstallingAlways On ESEpowerpanelprotectiondevices,these
problemswillnotoccur.

Always On ESEPowerprotectionoffersTWOMethodsof
Protection
1)ForallNewResidential,CommercialandIndustrialConstruction:
TheESEprotectselectronicequipmentinnewbuildings(security,environmental,networking,communications,
appliances,systems,etc.)frompotentiallydestructiveanddisruptiveexternallygeneratedpowerspikesand
transients,massivesurges,indirectlightningstrikes,lowfrequencyharmonicsandcommonandnormalmode
noise.
2)ForallCommercialandIndustrialRetrofits:
Incommercialandindustrialenvironments,theESEoffersthesamefeaturesasaboveandprotects
downstreambranchpanelsfromexternallyandinternallygeneratedpoweraberrationssuchasspikes,
transients,massivesurges,lowfrequencyharmonicsandcommonandnormalmode
noise.
Stoptheproblemsbeforetheycanoccur.Eliminateallpotentialproblemcausingand
damagingpoweraberrationsbyhavinganAlwaysOnESEfilterinstalled.
Features
TheESEfeaturesselfdiagnostics,LEDindicatorsandremovablefusesperphase,which
eliminatededicatedandcostly3phasepanelbreakers.

*Productsmaynotnecessarilybeasshown.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 28


Electrical Service Entrance
Specifications
Frequency 50/60Hz
Voltages 208,240,480,600V(othervoltagesavailable)
Phases WyeorDeltathreephaseandsinglephase
Protectionmodes 10for3wye,6for3delta,5for2wye
Technology Bidirectionalparallel
Insertionloss Nominal60dB,MilStandard220A@100kHz
Bandwidth 10kHz50MHzor180Hz50MHz
Responsetime Constant/Instantaneous
Standards UL1449Rev2009(SPD)Peak
SurgeCurrent 60kAto600kAperphase
Sinkcurrentcapacity/phase 25A
Operatinghumidity 097%(noncondensing)
Operatingtemperature 40C65C
Warranty 10years
Enclosure NEMA12(oroptionalNEMA4)flangemount
Dimensions 14"x12"x6"
Weight 13.6kg/30lbs(approximately)
Optional FMFlushmountcontainer(DIM12"x12"x6")
Specifications are subject to change without notice to reflect upgrades and improvements in technology.

DescriptionofModelNumber
ESE 200K 208 Y (FM)(Optional)

SURGECURRENTperphase
60K* 60kAperPhase
Modeltype Voltages** Configuration Flush
100K 100kAperPhase
ESE 120K 120kAperPhase 208 WyeorDelta*** Mount
160K 160kAperPhase 240
***Contact
200K 200kAperPhase 480 manufacturerformore
250K 250kAperPhase 600 informationonDelta
300K 300kAperPhase version.
400K 400kAperPhase **Othervoltage
500K 500kAperPhase optionsavailable.
600K 600kAperPhase Consultmanufacturer.
ForallUPCordercodes,visit:
*Note:60Kversionisforresidentialuseandcomesinthe240Volt/Splitphase www.alwayson.com
configurationonly.Itisnotrecommendedforcommercialorindustrialapplications.

MODEL SURGECURRENT VOLTAGE YorD OPTION MODEL#


ESE 60K 240 Y ESE60K240Y(SHP)
ESE 250K 480 D ESE240K480D
ESE 500K 600 Y FM ESE500K600YFM
Surgecurrent:60K,100kto600k
208/240/480/600VOLTS
YNeutralwirerequired(Wyetypetransformer) EXAMPLES
DNeutralwirenotrequired(Deltatypetransformer
FMFlushMountContainer *Optional
AdditionalCost

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 29


PLC Two-Plus & Two-Plus-Two
SPD Filters: Three-Wire Grounded / Two-Wire Ungrounded
&
Data Line Filters: Three & Four Wire Data Bus Protection

ACPowerandDataLineProtectionInOneConvenientBox
Todayscompetitivemarketsrequireallindustrialequipmenttofunctionat
maximumperformance.Lowerprofitsrequirehigheryieldsorproduction.
Thisisachievedbymaintainingproductionequipmenttorunatitsoptimum
level.Increasedproductionmeansincreasedprofits. Userresettable
TheAlwaysOn PLC2+2and2+0SurgeProtectionDevice(SPD)anddataline breakeronallmodels
filterwillprovidetodaysusersandOEMswiththeultimateprotectionrequiredbytodaysautomated
industries.Always On has25yearsinthenoisesuppressionandpowerqualityindustry,providingusthe
knowledgebaserequiredtoremainonthecuttingedgeofthepowerprotectionindustry.

Applications:Amongotherapplications,thePLCProtectorcanbeappliedtoPLCs,robotics,CAD/CAM,alarm
systems,scanners,controllers,medicalequipmentandvirtuallyallmicroprocessorbasedcriticalequipment.
Uses:TypicalPLCProtectorusesincludetheoilindustry,refineries,thepulpandpaperindustry,thetextile
industry,waterandsewertreatmentplants,thepetrochemicalindustry,thefoodprocessingindustryand
virtuallyalltypesofmanufacturers.

Features/Benefits
SeriesHybridDesign:SinewavetrackingTVSStechnologyensuresfastandimmediateattenuationofthe
harmfulspikes,transientsandbothcommonandnormalmodenoise.Theaddeddatalinefilterensuresthatthe
2+2Filterwillprotecttheattachednetwork/communicationlinkfromallpotentialproblems.TheAlwaysOn
2+2filteristheonlyfilterthatoffersallmodesofprotectiononboththepowerlineandthedataline.The
AlwaysOn2+2onetwopunchwillguaranteemaximumruntimesforyourequipment,resultinginhigher
productionandprofits,whiledecreasingdowntimeandequipmentrepaircosts.
Suppression/Attenuation:ThecuttingedgetechnologycontainedintheAlways On 2+2and2+0filtersallow
normalmodenoiseattenuationupto85dBandforcommonmodenoiseattenuationupto50dB.Itfilters
bandwidthsof10kHzto100MHz,withatotalpeaksurgecurrentof32,500amps,whileprovidingaresponse
timeoflessthan1nanosecond.
FunctioningIndicator:TheeasilyseenthreecolourLEDinformstheuseroftheworkingstatusoftheAlwaysOn
2+2and2+0filter.
OptionalCommunications:FormA,BorCcontactsallowtheusertomonitorthestatusofthe2+2or2+0filter
fromaremotelocation.
MountingOptions:The2+2and2+0comestandardwithJRailoranoptionalflangemountingisavailable.
ProductWarranty:AlwaysOn 2+2and2+0filtersarewarrantedagainstfailurefortwoyears(exchangeor
repairwarranty).
5YearUserGuarantee:AlwaysOn guaranteesagainstelectricaldamagetotheprotectedpowersuppliesby
poweraberrationsfor5years.

Conclusion
ThePLC2+2and2+0filtersincreaseuptimestothemaximum,whichincreasesproductionandresultsinhigher
profits.Italsoofferssubstantialsavingsthroughdecreaseddowntimeanddecreasedrepaircosts.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 30


PLC Two-Plus & Two-Plus-Two
4TypesofHighEndProtectioninOneBox
ACPowerConditioning(inbothTwoPlus&TwoPlusTwo)
SurgeProtectionUtilizingSPD/HybridDesign

TwoPlus&TwoPlusTwo 3WireGrounded PhysicalData


Operatingvoltage 120Vacsinglephase Container DinRail/FlangeMount
Powerrating 360VA/600VA/1200VA/1800VA OperatingTemperature 40to60C
Amperage 5/10/15 110x75x110mm
Dimensions
Frequency 50/60Hz (4.375"x2.75"x4.375")
Protectionmodes LN,LG,NG Weight 2kg/4.5lbs
Maximumclampingvoltage 150V
Noise Normalmode 85dB@100kHz Specificationsaresubjecttochangewithoutnoticeto
attenuation Commonmode 50dB@5MHz reflectupgradesandimprovementsintechnology.
Filterbandwidth 10kHzto100MHz
Totalpeaksurgecurrent Upto32500A
Joules Upto750Joules
Responsetime <1nanosecond
Indicators StatusandfaultLED
Options Drycontacts(forremotemonitoring)

DataLineProtection(TwoPlusTwoOnly)
ThissolidstatesemiconductorseriesofferssurgeprotectionforlinetolineandlinesA,B,commonandshieldto
ground.Itisdesignedfor3wireand4wiredatabuscommunicationsthatrequireapproximately5Vdcdifference
betweenlineandline.ItiscompatiblewithDeviceNet,DataHighwayPlus,ModbusPlus,GeniusBus,SimaticNet,
Profibus,CompoBus/S,RS485,RS422,TwistedPair,3WireandIndustrialNetworksupto100Mb/sec.

TwoPlusTwo
StrikeBreakdownVoltage 13V@100V/Sec,10.5V@100V/Sec
MaxDCOperatingVoltage 9.6Vdc
ClampingVoltage 81V
MaximumSurgeCurrent 1kA
MaxCapacitance(ABLines) LL2.9pF,LG73pF
DeviceNet Includes24VdcBusprotection

ModelNumberDescription
PLC 2+2 120 15 AC DP DCA

ModelStyle ModelType Voltage CurrentRating ACFilter DataandVdcFilter DryContacts


PLC 2+2 120 5 AC DP(2+2only) DCA DCB
2+0 240 10 DCC(2+0only)
15

Formoreinformation,visitwww.alwayson.com

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 31


NFC Series
Three Phase In / Out
Frequency Converters & Voltage Regulators
Industrial / Commercial

50or60HzInputFrequency/50,60,or400HzUserDefinedOutputFrequency
TheAlwaysOn NFCSeriesFrequencyConvertersaremanufacturedtoprovideclean,
regulatedandcontrolledpoweratthecustomerspecifiedvoltageandfrequency.Basedon
theAlwaysOnNXSeries,theNFCSeriesprovidesclean,isolated,reliableandconsistent
powertoallcriticalloadsattheexpectedlevelsrequired.
TheNFCSeriesFrequencyConvertersareintelligent,dualconversion,online,threephase
systemsforcentralizedfrequencyconversion,powerprotectionanddistribution.The
dualconversionmeansACutilityisconvertedintoDCpowerwhich,inturn,chargesthe
batteriesandsuppliestheinverter,whichinvertstheDCpowerbackintohighlyregulated
andisolatedACpowersuppliedatafrequency(50,60,or400Hz).Thiscontinuousonline
FrequencyConverterisavailableinmodelsfrom10kVAupto250kVA.Thisdualconversion
preventspoweraberrationsfromaffectingtheconnectedloads.
TheNFCSeriesFrequencyConvertersprovidereliableandrobustprotectionandfrequency
conversion, allowing for reliable and protected power to be available for all specific and
criticalloads.

FeaturesandBenefits
FrequencyConversion:Thispermitstheusertoconfigureasystemwithanyinputvoltage(208,480or600)and
inputfrequency(50or60Hz)withanyoutputvoltage(208/120,480/277or600/347)andoutputfrequency(50,
60or400Hz),independentoftheinputconfiguration.
FullGalvanicIsolation:FullGalvanicIsolationprovidesacompletelyisolatedandreferencedoutput.This
isolationprotectionprovidesaprovensolutiontoproblemscreatedbyinducedvoltagesaffectingthecritical
loads.Sincetheoutputcircuittotheloadiscompletelyisolatedandnonoiseinducedontheneutralcan
permeatetotheloads,systemsoperateinamorereliablefashion.Also,thistypeofprotectionincreasesthelife
spanofequipmentbyeliminatingnoise,whichbreaksdowncomponents.
ModularDesign:Eachmajorcomponent(inverterandrectifier)ontheNFCSeriesFrequencyConvertersare
installedonslideoutmodules.Thisallowsforquickrepair(meantimetorepairof<30minutes)andeasyfield
upgradability.
Highefficiency:ThankstoIGBTtechnology,theNFCSeriesFrequencyConvertersprovidehighefficiency.
Fullydigital:DSP(DigitalSignalProcessor),flashmemoryandPWMstrategyarethetechnologycornerstonesof
thenewageofpowerqualityandreliability.
Extremelyflexible:TheNFCSeriesFrequencyConvertersoffertailormadepowerprotectiontocomplywith
yourindividualinstallationrequirements.Optionsincludea12pulserectifierandaSmartPanel(SP).Inaddition,
acomprehensivesoftwaresuitecanbeaddedformissioncontrolanddataprotection.
OptionalBatteryBanks:AlwaysOn hasalsoallowedfortheoptionofbackuptimetobeaddedtothesystem
toeliminatetheneedofpurchasingaUPSsystemandafrequencyconverter.Thisruntimepackagewillallowfor
UPSlikeoperationatauserspecifiedfrequency(50,60,or400Hz).

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 32


NFC Series
FrequencyConverters:50or60HzInputFrequency/50,60,or400HzUserDefinedOutputFrequency 10kVA250kVA
GeneralData
Topology TrueOnLine,DualConversion
NominaloutputatPF=0.8 kVA 10 15 20 30 40 50 60 80 100 160 250

Overall 100%load,0.9PF % 91 91 91 91 91.5 92 92 92.5 92.5 93 93


efficiency
50%load,0.9PF % 89 89 89 89 89 91 91 91 91 92 92
Truegalvanicisolationfrominputtooutput YES
Heatrejectionat100%load,0.9 BTU/hr 3070 3510 4440 6480 8870 10200 11900 15700 184002970044460
PFandchargedbattery (kW) (0.9) (1.0) (1.3) (1.9) (2.6) (3.0) (3.5) (4.6) (5.4) (8.7) (13)
Audiblenoiselevel(at1m) dB(A) <65at1mmaximum <67at1mmaximum
Operating UPS 0C40C(32F104F)
temperature
range Battery Optimum20C25C(68F77F);highertemperaturesreducebatterylifeexpectancy

Storage UPS 15C50C(5F122F)


temperature Battery 0C40C(32F104F)
range (VRLA) Storagetimeis6monthsat25C(77F);highertemperaturesreducebatterystoragetime
Relativehumidity 090%,noncondensing
Maximum
Withoutderating <1500m,(5000ft),noderating
altitude
Type Indoor(NEMA1)[Optionaldripshieldavailable][Otherconfigurationsavailable]
Safety Internaldeadfrontconstruction
Enclosure
Cooling Forcedair(bottomtotop)
Colour Manufacturercolour(ivory)
Rigging Suitableforhandlingbyforklift
Mounting Castersandfloormountingbrackets
Installation Installation&maintenance
Frontaccessrequiredfornormalmaintenance
access
Conduitaccess Bottomentrystandard[Optionaltopentry]
Standards UL1778,IEC62040,FCCClassA,EN500911,2
Electrostaticdischargeimmunity 6kV
Standard Standalone
Configuration
Optional IPRO(2unitsworkinginparallel)
Specificationsaresubjecttochangewithoutnoticetoreflectupgradesandimprovementintechnology.

NFCSeriesFrequencyConverterSingleLineDrawing

ForAlwaysOn UPCordercodes,visitwww.alwayson.com

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 33


Aurora & Borealis
Emergency Lighting Inverters
Single Phase / Three Phase

AURORASeriesEmergencyLightingACInvertersareamongthemostreliablecentral
systemsavailableforemergencylightingandotherdemandingcriticalapplications.
TheAURORASeriesEmergencyLightingACInvertersareDualConversion,Online,
singlephase,intelligentsystemsforcentralizedpowerprotectionanddistribution.The
DualConversionmeansitconvertstheincomingACpowertoDC,chargesthebatteries,
theninvertstheDCbackintohighlyregulatedisolatedACpower.Thesecontinuouson
lineEmergencyLightingACInvertersareavailableinmodelsfrom3kWto15kW.
TheAURORASeriesEmergencyLightingACInvertersprovidereliableandconstant
protectionforlifesafetyemergencylighting,andinfrastructureapplicationssuchas
airports,hospitals,andresidences.

BOREALISSeriesEmergencyLightingACInvertersareamongthemost
reliablesystemsavailableforemergencylightingandotherdemandingcritical
applications.
TheBOREALISSeriesEmergencyLightingACInvertersareDualConversion,
Online,threephase,intelligentsystemsforcentralizedpowerprotection.
ThesecontinuousonlineEmergencyLightingACInvertersareavailablein
modelsfrom8kWupto48kW.
TheBOREALISSeriesEmergencyLightingACInvertersprovidereliableand
constantprotectionformissioncriticalemergencylighting,andinfrastructure
applicationssuchasairports,hospitals,andfinancialcompanies.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 34


Aurora
Single Phase ELI

FeaturesAndBenefits
TheseELIsprovidefulltimeselfdiagnosticsaswellastwolevelsofaudiblealarmswhentheunitisoperatingin
batterymode.Amanualtestfunctionhasbeenincorporatedintotheinput/testbreakersthatmakebattery
testingasimpleandsafeprocedure.TheinternalbypassswitchallowsmaintenanceontheELIstobeperformed
withoutinterruptionofpowertotheload.
Thecommunicationsport,inconjunctionwithmultiplatformmonitoringandcontrolsoftware,enablestheunit
tobeconnectedtoalocalornetworkedcomputersystem.Detailedoperatinginformationincludingvoltages,
currents,andalarmstatusisavailabletothemonitoringsystem.

FullGalvanicIsolation:Providesacompletelyisolatedandrereferenceoutput.Thisisolationprotection
providesaprovensolutiontoproblemscreatedbyinducedvoltagesaffectingthecriticalloads.Sincetheoutput
circuittotheloadiscompletelyisolatedandnonoiseinducedontheneutralcanpermeatetotheloads,systems
operateinamorereliablefashion.
Fullydigital:CPUcontrol,flashmemory,andPWMstrategyarethetechnologycornerstonesofthenewageof
powerqualityandreliability.
Extremelyflexible:TheAURORASeriesofferstailormadepowerprotectiontocomplywithyourindividual
installationrequirements.Optionsincludeadditionalruntime,remotemonitoringpanel,anddistributionpanels.
Inaddition,acomprehensivesoftwaresuitecanbeaddedformissioncontrolanddataprotectioncoversallyour
applicationneeds.
IMBS:AninternalmaintenancebypassswitchisstandardwithallAURORAsinglephaseinverterunits.
EMIsuppression:AnEMIfilterisaddedtomeettheinternationalEMClimitstoensurethatnonoisewilleffect
orinterferewithotherequipmentconnectedtothesameACsource.
Highfrequencydesign:Theinverterdesignincorporateshighfrequency,highefficiencyInsulatedGateBipolar
Transistors(IGBT).APWMwave,synchronizedtothebypassinput,triggerstheIGBTs,whichinverttheDCinto
ACpowerrequiredbytheloads.Thisdesigndecreasesthenumberofrequiredcomponents,increasesreliability
andperformancewhiledecreasingacousticnoise,sizeandweight.
Coldstartfunction:TheAURORAcanbestartedwithouttheutilityACsupplybeingactivated,orpresentatthe
inputterminalstripbecauseoursystemisdesignedwithcurrentlimitingcircuitry,whichallowsstartupofthe
AURORAonbatteryDCpower.
Intelligentbatterytest:Thebatteriesaretestedmonthlyautomatically.Whenanabnormalcondition(low
chargerating,orbadbattery)isfoundtheuserwillbeinformedimmediatelythroughalarmsontheAURORA
systems.
MTBFofcoolingfans:Longcyclingfanswilloperateatvariablespeedsnecessarywhichisdependentontheload
oftheinvertersystemsincreasingthelifeexpectancyofthefanmotors.

Options
OutputCircuitBreakers:Supportsnormallyonornormallyoffcircuitbreakers.
AdditionalRunTimes:Thesecanbe30,60,90,or120minutes,otherconfigurationsareavailable.
EMBP:ExternalMaintenanceBypass.Thisdeviceallowstheloadpowertobetransferredfromtheinverter
outputtotheACsupply.Thustheinvertercanbecompletelyremovedorrepairedwithoutinterruptionofpower
totheload.
RCMP:RemoteControlandMonitoringPanel.Thisoptionprovidesremotealarmstoindicatetheinverterstatus.
SNMP:SNMPadaptertoremotelycontrolandmonitortheunitviaanetworkortheInternet.

ConsultAlwaysOnUPSforotherfeaturesandoptions.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 35


Aurora
Single Phase ELI
3kWto15kW
Model 3kW 5kW 7.5kW 10kW 15kW
Phase/Frequency Singlephase(2wire+ground)50/60Hz
Ratedvoltage 208/240/277/347Vac
Voltagerange 15%
Input
208/29A 208/40A 208/60A 208/74A 208/113A
240/25A 240/35A 240/53A 240/64A 240/98A
Inputcurrent
277/22A 277/30A 277/45A 277/56A 277/85A
347/18A 347/24A 347/36A 347/45A 347/66A
Voltage/Phase 208/240/277/347Vac(Singlephase,2wire+ground)
Voltageregulation 2%
208/14.4A 208/24A 208/36.1A 208/48.1A 208/72.1A
240/12.5A 240/20.8A 240/53A 240/41.7A 240/62.5A
Maximumcurrent
277/10.8A 277/18.1A 277/27A 277/36.1A 277/54.2A
347/8.6A 347/14.4A 347/21.6A 347/28.8 347/43.2A
Frequency 50Hz/60Hz0.5%
THD <3%linearload;<5%rectifiedload
Output Slewrate 1Hz/second
Transientresponse 4%(100%loadchange)
110%125%for1min,thenswitchtobypass
Overloadcapacity
125%150%for10sec,thenswitchtobypass
Crestfactor 3:1
Efficiency(ACAC) >85%
Transfertime 0ms
Outlets Hardwired
DCSystem DCsystemvoltage 240Vdc
Outputshort YES
Abnormalvoltage YES
Protection
I/Onoiseprotection Common&normalmodenoisesuppression
I/Ospikeandtransientprotection YES
Communication RS232/Drycontact/(OptionalSNMP)
Interface Display LCDindicatorstatuspanel
Audiblealarms Onbattery,lowbattery,overload,fault
Operatingtemperature 040C
Humidity 0%95%(noncondensing)
Environment
Audiblenoise 55dBAat1mfromunit
Elevation 3500metersmaximum
Safety UL1778,UL924,CSAC22.2,CSA107.3,NFPA111
Safetyapproval EMI/RFI FCCSection15ClassA
Surge/Transient IEEEC62.41Cat.A
WxDxH(mm) 450x725x1026 1070x690x1705
Physicaldata
Weight(kg) 130 150 150 431 760
Specificationsaresubjecttochangewithoutnoticetoreflectupgradesandimprovementintechnology.

Standardchargersize:3kWto7.5kWis5A/10kWto15kWis10A.
Othervoltageratingsandconfigurationsareavailable;forordercodes,consultmanufacturer.
ConsultAlwaysOnUPSforavailableruntimesandmoreinformation.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 36


Borealis
Three Phase ELI
FeaturesAndBenefits
TheseELIsprovidefulltimeselfdiagnosticsaswellastwolevelsofaudiblealarmswhentheunitisoperatingin
batterymode.Amanualtestswitchhasbeenincorporatedintotheinput/testbreakersthatmaketestinga
simpleprocedure.TheinternalbypassswitchallowsmaintenanceontheELIstobeperformedwithout
interruptionofpowertotheload.
Thecommunicationsport,inconjunctionwithmultiplatformmonitoringandcontrolsoftware,enablestheunit
tobeconnectedtoalocalornetworkedcomputersystem.Detailedoperatinginformationincludingvoltages,
currents,andalarmstatusisavailabletothemonitoringsystem.

FullGalvanicIsolation:Providesacompletelyisolatedandrereferenceoutput.Thisisolationprotection
providesaprovensolutiontoproblemscreatedbyinducedvoltagesaffectingthecriticalloads.Sincetheoutput
circuittotheloadiscompletelyisolatedandnonoiseinducedontheneutralcanpermeatetotheloads,systems
operateinamorereliablefashion.
Fullydigital:DSP(DigitalSignalProcessor),flashmemory,andmulticontactstrategyarethetechnologycorner
stonesofthenewageofpowerqualityandreliability.
Extremelyflexible:TheBOREALISSeriesofferstailormadepowerprotectiontocomplywithyourindividual
installationrequirements.Optionsincludea12pulserectifier,anddistributionpanels.
IMBS:AninternalmaintenancebypassswitchisstandardwithallBOREALIS3phaseinverterunits.
EMIsuppression:AnEMIfilterisaddedtomeettheinternationalEMClimitstoensurethatnonoisewilleffect
orinterferewithotherequipmentconnectedtothesameACsource.
Highfrequencydesign:ThethreephaseBOREALISdesignincorporatesafullbridgethreephaseinverter.This
designmakestheBOREALISperformbetterthanotherEmergencyLightingACInvertersinthemarketwhenan
unbalancedloadisconnected.
Coldstartfunction:TheBOREALIScanbestartedwithouttheutilityACsupplybeingactivated,orpresentatthe
inputterminalstripbecauseoursystemisdesignedwithcurrentlimitingcircuitry,whichallowsStartupofthe
BOREALISonbatteryDCpower.
Intelligentcharger:TheBOREALISwillperformanautomaticmonthlyrecharge(boostcharge)ofthebatteriesas
wellasautomaticallyrecharge(boostcharge)thebatterieswhenthebatteryvoltageleveldecreasesto
approximately2V/Cell.Itmakesthebatteriesstayingoodcondition.
Intelligentbatterytest:Thebatteriesaretestedmonthlyautomatically.Whenanabnormalcondition(low
chargerating,orbadbattery)isfoundtheuserwillbeinformedimmediatelythroughalarmsontheBOREALIS
systems.
MTBFofcoolingfans:Longcyclingfanswilloperateatvariablespeedsnecessarywhichisdependentontheload
oftheinvertersystemsincreasingthelifeexpectancyofthefanmotors.
SNMP:SNMPadaptertoremotelycontrolandmonitortheunitviaanetworkortheInternet.

Options
OutputCircuitBreakers:Supportsnormallyonornormallyoffcircuitbreakers.
AdditionalRunTimes:Thesecanbe30,60,90,or120minutes,otherconfigurationsareavailable.
EMBP:ExternalMaintenanceBypass.Thisdeviceallowstheloadpowertobetransferredfromtheinverter
outputtotheACsupply.Thustheinvertercanbecompletelyremovedorrepairedwithoutinterruptionofpower
totheload.
RCMP:RemoteControlandMonitoringPanel.Thisoptionprovidesremotealarmstoindicatetheinverterstatus.

ConsultAlwaysOnUPSforotherfeaturesandoptions.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 37


Borealis
Three Phase ELI

8KWto48KW
Rectifier 8kW 12kW 16kW 24kW 32kW 40kW 48kW
Inputvoltage 120/208V277/480V347/600V3phase,4wire+ground
Inputrange 15%
Inputfrequency 4565Hz
Inputpowerfactor <1
Normalinputcurrent(basedon208Vac) 31 47 62 93 124 155 186
Maximuminputcurrent(basedon208Vac) 36 54 71 107 142 178 213
6pulse:30%
THD
12pulsewithfilter:9%
Powerwalkin(adjustable) 0%100%:20seconds
Efficiency 98%
Voltageregulation 1%
Ripplevoltage 0.50%

Battery 8kW 12kW 16kW 24kW 32kW 40kW 48kW


Batterytype Maintenancefreesealedleadacid
Numberofcells 174
Voltagerange 295410Vdc
Maximumchargecurrent(ADC) 5 7.5 10 15 20 25 30
Batterylowvoltage 320Vdc
Batterylowstop 295Vdc

Inverter 8kW 12kW 16kW 24kW 32kW 40kW 48kW
DCinputrange 295415Vdc
Waveform Sinusoidal
Outputvoltage(adjustable) 120/208V,277/480V,347/600V,3phase,4wire+ground
Crestfactor 3:1
Outputpowerfactor 0.8
Voltageregulation100%unbalanceload 1%
Frequencylockrange 50/60Hz,7%
Outputfrequency(freerunning) 50/60Hz,0.1Hz
Static 1%
Outputvoltagetolerance
Loadstep0%100%0% Recoveringtowithin1%in4cycles
THD(linearload) <2%
<110% Continuous
110125% 15minutes
Overload 125150% 5minutes
150170% 30seconds
>170% 10seconds
Efficiency(100%load) 92%
Maximumoutputwattage(kW) 8 12 16 24 32 40 48
Specificationsaresubjecttochangewithoutnoticetoreflectupgradesandimprovementintechnology.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 38


Borealis
Three Phase ELI
8KWto48KW
Staticswitch 8kW 12kW 16kW 24kW 32kW 40kW 48kW
Voltagerange 20%ofinputvoltage(linetoneutral)
Frequencyrange 4555Hz/5565Hz
Efficiency 99.50%
Mains>Inverter 0ms
Transfertime
Inverter>Mains 0ms
Isolationwithoutput YES

Overallcharacteristics 8kW 12kW 16kW 24kW 32kW 40kW 48kW
Overallefficiency 90%
Maximumheatdissipation(kW) 0.89 1.32 1.76 2.64 3.52 4.40 5.28
Temperature 040C(32104F)
Operatingenvironment Humidity 090%(noncondensing)
Altitude <1500mabovesealevel
Shortcircuit YES
Lightning MOV
Protections
EMCfilter Input&output
Galvanicisolation Betweeninput&output
Indicationsandalarms LED,LCD,Buzzer
Drycontact YES
Batterystart YES
DatadisplaybyLCD YES
Audiblenoise <65dBA(at1m)
Standards UL924,UL1778,NFPA111,CSA107.3,CCMC,BMEC,CSA22.260950
WxDxH(mm) 550x812x1600
Physicaldata
Weight(kg) 380 415 450 580 650 710 850
Specificationsaresubjecttochangewithoutnoticetoreflectupgradesandimprovementintechnology.

TheinputvoltagesareWYEorDelta,buttheoutputvoltagesare3phase4wireplusground(WYE)configuration.
Othervoltageratingsandconfigurationsareavailable.
Forordercodes,consultAlwaysonUPS.
ConsultAlwaysOnUPSforavailableruntimesandmoreinformation.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 39


Genie Smart Panel / Cabinet
UPS Powered Fault Protected System
(OneCycleClearing)
TheGenieisdesignedtosupplyACpowerandisolatemultiplecriticalloadsfed
byonepanel.GenieismanufacturedinourISO9001:2008certifiedfacilitiesand
incorporatestheAlwaysOnSpecificallyDesignedBreaker(SDB).GENIE
protectstheconnectedloadsfromreactingtoproblemscausedbyshort
circuits,i.e.momentarylossofvoltage(openingcontacts,rebootsetc)andhigh
currentspikescreatingapossiblehazardatthefailedorshortedloads.During
shortcircuitconditionwithastandarddistributionpanel,theUPSwillbeautomaticallytransferredtostatic
bypassmodeallowingtheinpututilitytosupplydangerouslyhighcurrents(approximately1000%ofthe
maximumUPScurrent)for18to22cycles(thenormalamountoftimeastandardbreakerrequirestoclear).
Alsoduringthetimetheloadbreakerisbeingclearedalargetransientwillbecreatedresultinginpossible
damagedequipment.Intheeventthefaultedloadbreakerisnotcleared,theUPSwillshutdown,dueto
extendedoverload,ortheUPSinputbreakerwillclearcausingapowerloss.
GenieisdesignedtoidentifyanoverloadconditionandcleartheSDBinadvanceofatotalloadfailure
preventingdamagingand/ordangerousshortcircuitsandhighcurrentconditions.
GenieSDBsaredesignedtoclearoropeninlessthanonecycleeliminatingthetimewindow(18to22
cyclesofstandardbreakers)whichallowstheshortcircuitevolutionofproblemstobegin.
GenieSDBsintelligentdesigndistinguishesthedifferencebetweennormalinrushcurrentforequipment
andashortcircuitoroverloadcondition.
GenieSDBsaresimplepluginbreakerdesign,foreasyupgradeorreplacement.

Options
Communicationport:GENIEcanincorporatearelay
communicationinterfaceandalarmstoallowfor
notificationofanopenSDB. Complete
PowerProtection:SPDprotection200kAsurgecurrent custom
to600kAsurgecurrentprotectionisavailable. configurations
available!
RemotePanelwithAudibleAlarm:Configuredwith
notificationDisplayandAlarmsfunctiontoidentify
openSDB.
Compatibility:TheGENIEisdesignedspecificallyfor
AlwaysOn UPSproductsbutcanbeutilizedto
supportothermanufacturedUPSproducts.

Patented in Canada: Patented in the USA:


# 2 496 365 # 7 557 468

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 40


ALW Batteries & Battery Bank Units
ALWBatteries
AlwaysOnUPSSystemsCanadaInctakesgreatprideinourALW
Seriesbatteries.Yearsofresearchanddevelopment,alongwithISO
9001:2008qualitymanagementsystemsandULListing,ensurethe
highestqualityandperformancefromourbatterysystems.Therange
ofbatterysizesandcapacitiesisuniqueintheindustry,andtheir
specificationsareoptimizedtoensuremaximumperformanceforour
broadrangeofUPSbackuppowerandEmergencyLightingInverter
Systems.
Ourtoughstandardsduringmanufacturing,qualitycontrolandtesting
ensurethatonlybatteriesmeetingthetightspecificationsoftheproduct
areintegratedintotherestofoursystemdesigns.Ourspecialprocessofgrouping
batterytypesduringtransportandstoragemaintenanceallowsustoeasilymatchourbatteriesduringassembly
ofourbatterycabinets.
AspartofourcertificationbyCSAandlistingbyUL,eachbattery,chargerandinverterofafullyassembled
systemisaccuratelycalibratedandvigorouslytestedthrougheachmodeofoperation,includingbattery
dischargeandrechargecycles.Thisisdonetoensurethatthecompletesystemisincompliancewiththe
requiredsafetystandards.

ALWBatteries ALW3612UPS ALW5612UPS ALW8512UPS ALW11012UPS ALW16012UPS


Capacity(25C/77F) 36Ah 56Ah 85Ah 110Ah 160Ah
Voltage 12V 12V 12V 12V 12V
Weight 12.6kg/27.7lbs 17.5kg/38.5lbs 26.0kg/57.2lbs 32.0kg/70.4lbs 45.5kg/100.1lbs

BatteryCabinets
Ourbatterycabinetscomeinavarietyofsizestosuityourbackuptimeneeds.Forevenlongerruntimes,
multiplecabinetscanbeusedtoincreasestoragecapacity.Thecabinetsthemselveshaveseveralusefulfeatures,
suchas:
Heavydutycasters.
ConvenientbatterycablewithAndersonquickconnects.
Retractablebatterytrays,makingbatterytestingandreplacementeasy.

Dimensions KA,KB,KC,KD,KEcabinets KF,KG,KH,KI,KJcabinets


mm 812Wx863Dx1945H 1314Wx850Dx1945H
inches 32Wx34Dx76.6H 51.7Wx33.5Dx76.6H

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 41


UPS Preventative Maintenance Program

AlwaysOnsUPSsystemsaredesignedformaximumreliabilityandpeakperformance.Evenso,aregular
maintenanceprogramisnecessarytoidentifyandcorrectpotentialproblemsbeforetheycanoccur.Thishelps
topreventunplannedandinopportunedowntimeandoutagesofcriticalsystems,morerapidlyaddresses
problemsthatcanoccur,andevenextendsbatterylifespan.

Aregularprogramthatinvolvesinspecting,cleaning,calibrationandfunctionaltestingofallmodesofoperation
ensuresfactoryspecifiedperformancethroughthelifecycleoftheUPSSystem.Recordkeepingisasnapshotin
timefortrackingandanalysisoftheresults,totrendthecomponentsperformanceasthesystemages.
Maintenancetakesintoaccounttheactualageofthespecificdevices,comparingexpectedperformancetothe
lifespan.ThisallowsustomonitorthehealthoftheUPSsystem,andtakecorrectiveactionsasnecessaryunder
preplannedconditions.

TheUPSautomaticmonthlyselftestcanbeenhancedwithincreasedfunctionalitythroughremotemonitoring
andtesting.Specificparameterscanbeprogrammedtotakeintoaccounttheactualsystemdesign
requirements,andlogtheresultsforanalysis.SecuredremoteaccesstoalltheUPSsinthenetworkallowfor
comprehensivecontrolandmonitoringfromonecentralizedlocation.Toaccuratelyassessbatterybackup
capacity,however,aloadtestandmeasurementmustbeperformedaspartofaregularmaintenanceprogram.

AnannualUPSmaintenanceprogram(orsemiannuallyinchallengingenvironmentalconditions)shouldbe
implementedaspartofausersregularmaintenanceprogram,andishighlyrecommendedaspartoftheoverall
equipmentbudgetandlifecycleplanning.

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 42


UPS Specification Questions
Project: Typeofloadtobepowered(Circleone,orfillother)
Company: Motor,Pump(HP:_______
PC
Contact:
Telecom
Phone: PLC
Email: Lighting
Fax: Electronic
Lifesupport(orMedical)
Iftenderavailablesendwithinformationabove.
InputVoltage(Circleone,orfillinother) Other:________________
1Phase 3Phase
2Wire 3Wire 4Wire Environmentalconsiderations
Temperaturerange:
120Vac 208Vac 120/208Vac
240Vac 480Vac 277/480Vac 040degreeCstandard

208Vac 600Vac 347/600Vac
Other:_______
Other:
Spaceconsiderations?
OutputVoltage(Circleone,orfillinother) Yes No

1Phase 3Phase IfYes,What?

2Wire 3Wire 4Wire

_____________________
120Vac 120/240Vac 120/208Vac

240Vac 277/480Vac
Vibration(earthquake):
208Vac 347/600Vac
Yes No

Other:
Whatstandard:____________

Enclosurerating:
PowerRequirements(Pleasefillinloadrequirements) NEMA IP

_____kVAor ______kWor ______A Other:___________

Backuptimerequirements

_______minutes Peripheralequipment:
RemotePanel
Applications(Circleone,orfillinother)
ExternalBypass
Commercial
Redundancy(3phaseonly)
Telecom
ExtendedWarranty
Industrial
24/7Warranty
Marine
OnsiteWarranty
Medical
ReplacementWarranty

ExtendedBatteryWarranty
Other:____________
EthernetCommunication(3phasestandard)
Relaycommunication(3phasestandard)

AlwaysOn UPSSystemsCanadaInc www.alwayson.com 43