Panoramic Powers Wireless Sensor Family

The Panoramic Power sensor series is made up of non-invasive, self-powered, miniature wireless current sensors. The
sensors clamp on the electrical outgoing wire from the circuit breaker and are self powered by the circuits magnetic
field. Hundreds of sensors can be installed in a few hours with no disturbance of daily operations. Once installed, the
sensors become part of the building infrastructure, never requiring maintenance, service or battery replacement.

PAN-10 & PAN-12 Sensors

SPECIFICATIONS PAN-10 SENSOR PAN-12 SENSOR PAN-10


Physical Dimensions 17 x 20 x 32 mm 46.2 x 22.8 x 32.6 mm
0.67 x 0.79 x 1.26 inch 1.82 x 0.90 x 1.28 inch

Max Hot-air Outer Diameter 7 mm 18.8 mm


(including insulation) 0.28 inch 0.74 inch

Current Measurement Range 0-63 A 0-225 A

Current Measurement Accuracy Typically <2% at I>1A Typically <2% at I>10A

Minimum Operating Current 0.3 0.45 A 0.5 0.8 A

AC Frequency Supported 50 Hz (EU) 50 Hz (EU) PAN-12


60 Hz (US) 60 Hz (US)

Transmission Frequency 434 MHz (EU) 434 MHz (EU)


902-928 MHz (US) 902-928 MHz (US)

Transmission Power (ERP) 0 dBm (Max) 0 dBm (Max)

Transmission Interval 10 seconds 10 seconds

Safety and EMC Certificates USA & Canada USA & Canada
Safety: UL-61010-1, Safety: UL-61010-1,
CSA-C22.2 (ETL listed) CSA-C22.2 (ETL listed) Key Features
EMC/Radio: FCC Part 15 EMC/Radio: FCC Part 15
Non-invasive, snap and
subpart B, C subpart B, C
fits without disconnection
Europe Europe
No maintenance;
Safety: EN-61010-1 (CE) Safety: EN-61010-1 (CE) self-powered
EMC: EN-ETSI 301489-3, EMC: EN-ETSI 301489-3,
Radio: EN-ETSI 300220-1 Radio: EN-ETSI 300220-1 High accuracy

Flammability Rating of UL94 V-0 UL94 V-0 Wireless no wiring,


External Enclosure unlike standard CT-based
monitoring systems
Operating Temperature 0 50 C / 32- 122 F 0 50 C / 32- 122 F
Real-time high-frequency
Storage Temperature -20 65 C / -4-149 F -20 65 C / -4-149 F current data transmitted
every 15 seconds
Panoramic Powers High Current Wireless Sensor (PAN-14)
The PAN-14 high-current sensor attaches to any size standard 0-5 A current transformer, allowing measurements at any
current range or wire gauge.

SPECIFICATIONS PAN-14 SENSOR PAN-14

Physical Dimensions 33.8 29 42.5 mm


1.33 1.14 1.67 inch

Current Input Range 0-5 ARMS (up to 10 A peak)


(from external current transformer)

Current Measurement Range Any applicable range based on CT ratio

Current Measurement Accuracy Typically <2% at I > 2% of full-scale current

Minimum Operating Current 0.03 0.05 A (at input from external current transformer)

AC Frequency Supported 50 Hz (EU version)


60 Hz (US version)

Transmission Frequency 434 MHz (EU)


915 MHz (US)

Transmission Power (ERP) 0 dBm (Max)


Key Features
Transmission interval 10 seconds
Connects to any standard
Safety and EMC Certificates USA & Canada 0-5A CT
Safety: UL-61010-1, CSA-C22.2 (ETL listed)
No maintenance;
EMC/Radio: FCC Part 15 subpart B, C
self-powered
Europe
High accuracy
Safety: EN-61010-1 (CE)
EMC: EN-ETSI 301489-3, Wireless sensor &
Radio: EN-ETSI 300220-1 CT are closed around the
hot wire with no additional
wiring
Real-time high-frequency
current data transmitted
Flammability Rating of UL94 V-0 every 15 seconds
External Enclosure

Operating Temperature 0 50 C / 32- 122 F

Storage Temperature -20 65 C / -4-149 F


Panoramic Powers Wireless Power Sensor (PAN-42)
The PAN-42 wireless power sensor provides high accuracy real time power measurements and advanced power quality
measurements for main power monitoring, submetering and for the metering of large devices. Designed for demanding
electrical applications, supporting industry accuracy standards, PAN-42 enables the metering of power, voltage,
current, power factor and power quality measurement data.

SPECIFICATIONS WIRELESS POWER SENSOR PAN-42 PAN-42


Description 4-wire Wye, 3-wire Delta, single-phase 3-wire, single-phase
2-wire, or dual-phase 3-wire
Voltage: [120V / 208V], [240V / 416V], or
[277V / 480V]
Frequency: 48-62 Hz
CT current input: standard 0-5 Arms
Current measurement range: Depending on
CT ratio
Minimum current (at device input) 0.05 Arms (1% of full scale)
Key Features
Outputs Active Energy (kWh) accumulated
Single or 3 phase metering
True RMS Voltage/Current per phase
Active/Reactive Power per phase Accurate measurement of
Power Factor per phase active and reactive power
Total Harmonic Distortion (%) per phase
Real time monitoring of
(Voltage and Current)
current, voltage, power
Frequency and power quality
Integrated within the
Accuracy (for Voltage, Panoramic Power cloud
According to ANSI C12.1 (Class 1%)*
Current and Active Energy) based energy management
* Pending certification testing and assuming CT of class 0.5 or better platform

Pulse Output 2 optically isolated outputs for active and Fast and easy installation
reactive energy (kWh)

Transmission Frequency 434 MHz (EU)


915 MHz (US)

Transmission Power (ERP) 0 dBm (Max)

Transmission Interval 10 seconds

Safety and EMC certificates USA & Canada Europe


Safety: UL-61010-1, Safety: EN-61010-1 (CE)
CSA-C22.2 (ETL listed) EMC: EN-ETSI 301489-3,
EMC/Radio: FCC Part 15 subpart B, C Radio: EN-ETSI 300220-1

Measurements Dimensions Weight


110.3 81 37.2 mm 200 g

Mounting Options Wall mount or DIN top hat rail EN50022 - 35x7.5

Flammability Rating of UL94 V-0


External Enclosure

Operating Temperature 0 50 C / 32- 122 F

Storage Temperature -20 65 C / -4-149 F

Display 3 LEDs for phase indications and additional LED for on line status indication.
The Full Portfolio of Wireless Sensors
Panoramic Power provides a comprehensive range of cost effective and easy to install metering and monitoring tools that
transmit real-time energy data to an its advanced cloud-based analytics platform.

PAN-10 PAN-12 PAN-14 PAN-42

Sub-metering and
Granular monitoring of individual circuits and devices monitoring of main power
lines and large devices

Panoramic Power is the leading provider of energy management solutions, enabling businesses to optimize their energy consumption,
improve operational efficiency and generate income through load response programs. Using its innovative and affordable circuit-level
cloud-base analytics solution, companies across a wide range of industries gain insight into their energy usage and are able to optimize
operations, processes and maintenance resources.

EMEA Americas
20 Atir Yeda St. 44 W 28 St
Kfar Saba 44643 New York, NY 10001
Israel T: 1-646-794-4241
T: +972-9-7667600 us-sales@panpwr.com
emea-sales@panpwr.com

Smart Energy. Smart Business www.panpwr.com

You might also like