APPENDIX C

ACCIDENTSUMMARYNo.17
AccidentType: Electrocution
WeatherConditions: Sunny,Clear
TypeofOperation: SteelErection
SizeofWorkCrew: 3
CollectiveBargaining No
CompetentSafetyMonitoronSite: YesVictim
SafetyandHealthPrograminEffect: No
WastheWorksiteInspectedRegularly: Yes
TrainingandEducationProvided: No
EmployeeJobTitle: SteelErectorForeman
Age&Sex: 43Male
ExperienceatthisTypeofWork: 4months
TimeonProject: 4Hours

BRIEFDESCRIPTIONOFACCIDENT

Employees were moving a steel canopy structure using a "boom crane" truck. The boom cable made contact
with a 7200 volt electrical power distribution line electrocuting the operator of the crane; he was the foreman
at the site.

INSPECTIONRESULTS

As a result of its investigation. OSHA issued citations for four serious violations of its construction standards
dealing with training, protective equipment, and working too close to power lines. OSHA's construction safety
standards include several requirements which, If they had been followed here. might have prevented this
fatality.

ACCIDENTPREVENTIONRECOMMENDATIONS

1. Develop and maintain a safety and health program to provide guidance for safe operations (29 CFR
1926.20(b)(1)).
2. Instruct each employee on how to recognize and avoid unsafe conditions which apply to the work
and work areas (29 CFR 1926.21(b)(2))
3. If high voltage lines are not de-energized, visibly grounded, or protected by insulating barriers,
equipment operators must maintain a minimum distance of 10 feet between their equipment and the
electrical distribution or transmission lines (29 CFR 1926.550(a)(15)(i)).

NOTE:TheFatalFactswereselectedasbeingrepresentativeoffatalitiescausedbyimproperworkpractices.Nospecialemphasisor
priorityisimpliednoristhecasenecessarilyarecentoccurrence.Thelegalaspectsoftheincidenthavebeenresolved,andthecaseis
nowclosed.Currentasof:11/01/2001.