UNIT MODELS & NOMENCLATURE

UNIT MODELS MODEL NOMENCLATURE


VERTICAL PACKAGED SYSTEMS
50UB 55
50UB SERIES
VERTICAL NOMINAL
50UB - 55 PACKAGE COOLING CAPACITY
50UB - 90
50UB - 110 55 = 55 MBh
50UB - 145 90 = 90 MBh
50UB - 180 110 = 110 MBh
50UB - 240 145 = 145 MBh
180 = 180 MBh
240 = 240 MBh

SPLIT SYSTEMS 38BB 55

38BB SERIES CONDENSING NOMINAL


UNITS COOLING CAPACITY
38BB - 55
55 = 55 MBh
38BB - 90
90 = 90 MBh
38BB - 110
110 = 110 MBh
38BB - 145
145 = 145 MBh
38BB - 180
180 = 180 MBh
38BB - 240
240 = 240 MBh

40AB 55

40AB SERIES evaporator NOMINAL


UNITS COOLING CAPACITY
40AB - 55 55 = 55 MBh
40AB - 90 90 = 90 MBh
40AB - 110 110 = 110 MBh
40AB - 145 145 = 145 MBh
40AB - 180 180 = 180 MBh
40AB - 240 240 = 240 MBh

1
Thank you for your choice of Carrier vertical packaged / split systems. These fine products have been carefully designed and
manufactured under strict quality conditions to give you full satisfaction through efficient operation with minimum maintenance and
service.

Carrier 50UB series were born of a very simple concept:


" An excellent product isn't enough; it must offer more than its competitors ".

In addition to true cooling, Carrier 50UB series have advanced features and performance level, which our competitors will find
difficult to equal, maintaining the same quality/ price ratio.

TAKE A LOOK AT THESE FEATURES


TRUE POWERFUL COOLING TROPICALLIZED

- Enhanced cooling capacity delivers more comfort than Carrier vertical packaged and split systems are designed
competitors. to work in very high ambient temperatures up to 52 oC
50UB efficient compressors lead to true unit cooling Perfo- due to efficient compressor, condenser coils and
rmance. evaporator coils.
- The declared capacity of the unit conforms with ARI standard
which ensure highest level of cooling capacity to be maintained LONG LIFE, CORROSION RESISTANT AND SOLID
long time period. CONSTRUCTION

SPLIT OR VERTICAL PACKAGED * Weather proof made of chemically treated, galvanized


steel sheet metal.
* Carrier split or vertical packaged systems are ideal for
installation in new buildings or refurbishment projects in * Powder painted with perfect adhesion of a highly
existing buildings. They are designed for small and medium resistant polyester paint.
sized air conditioning systems for commercial and residential
applications, such as restaurants, shops, laboratories, art * Side panels insulated with 10 mm self-extinguishing
galleries, offices and homes. thermal and acoustic insulation.
The units consist of two sections:
* Components are suitable for any climate.
An evaporator section (40AB) and a condenser section (38BB)
of matching size.

EASY SERVICE AND MAINTENANCE


OPERATING LIMITS
* The units have access from all side excellent compressor(s)
access and removal if necessary. All access panels have Dry Bulb Wet Bulb
Temperature OC
handles. Condensate water can be removed on each or both unit Temp. C Temp. C
side. Max. Inlet evap. Coil air 35 21
Min. Inlet evap. Coil air 19 14
* The control panel is located in a separate compartment and can Max. Inlet cond. Coil air 52
be inspected without disturbing unit operation. Min. Inlet cond. Coil air 19*
* For lower temperatures, optional head pressure conrol
QUALITY, RELIABILITY AND SAFETY must be used
- All materials included in Carrier split or vertical packaged
systems conform with the international standards of safety,
performance and reliability.
- Quality is ensured through receiving inspection testing and
through all stages of manufacturing, sales, installation and
servicing to finally ensure customer full satisfaction according
to ISO 9001 Quality System.

CE CERTIFIED

- 50UB series vertical packaged systems and (38BB + 40AB)


series split systems are CE certified according to European
regulations and norms of safety which are:
Low Voltage Directive LVD
Electro-Magnetic Compatibility Directive EMC
Machinery Directive MD

2
COMPACT DESIGN AND LIGHT WEIGHT VERSATILITY OF AIR DELIVERY

Units occupies limited space and has reduced weight, Front - Split system is delivered from the factory with evaporator
indoor air return design enables installation against the wall units having horizontal air discharge (case 1).
- Evaporator unit can be field converted for vertical air
LOW INSTALLATION COST discharge by using accessory supports (case 2).
Units are designed to provide high efficiency and dependable
operation for many years. They are delivered factory wired,
charged, and tested.
Their installation requires followings connections: electrical
power supply to thermostat and eventually, to air ducts, and in 1 2
case of split system, interconnecting refrigerant piping.
- Vertical packaged system can be delivered from the
Condensate water can be removed on each or both sides.
factory as per the following arrangements:
The control box is fully wired to European codes. Only the
installation of an isolator and fuses and connection to the
power supply.
Evaporator
When system is installed as split, the condensing unit Section
refrigerant piping connections are possible at the top or left or
right side. The evaporator unit can have refrigerant piping Condensing
installed on left or right side. Section

VERSATILITY OF LOCATION AND INSTALLATION

Units can be installed in office area, storage, or stock room or


other areas and no machine room is needed. They can be
placed close to the outside wall or at remote location because Evaporator
condenser air section can be ducted. Section
The evaporator unit can be ducted or installed for free blow
application with discharge air plenum. Condensing
It can be installed in low rise buildings and is also well suited to Section
high rise buildings.
Unit can be installed indoor or outdoor. When applied as a split
system, condensing unit can be installed inside or outside of
the building with water tight duct connections. It is suitable for Arrangemen Evaporator Evaporator
outdoor applications. t Air Return Air Discharge
A Horizontal back Vertical
TYPICAL INSTALLATION (Vertical Packaged system) B Horizontal back Horizontal front
1- Two system installed in interior zone of the motel with C Horizontal front Vertical
ducted evaporator air sections and through the wall D Horizontal front Horizontal back
outdoor air intake and discharge. (See Fig. 1)
2- system installed with discharge plenum and with through
the wall outdoor air intake and discharge. (See Fig. 2)
3- system installed in a storage area with ducted indoor air
discharge and with through the wall outdoor air intake and
discharge. (See Fig. 2)
4- system installed outdoor with ducted evaporator air Fig (2)
section.
5- system installed in interior zone with ducted condensing
and evaporator units. (See Fig. 2)

Fig (1)

3
GENERAL DESCRIPTION
CONDENSING UNIT
REFRIGERANT CIRCUIT COMPRESSOR
- Entirely deoxidized dehydrated copper tubes with Heavy-duty hermetic reciprocating compressor use R-22.
joints brazed by sliver brazing alloys. * Advanced internal discharge muffler.
* Advanced internal spring mounting.
- For units 110, 145, 180 and 240. * Multiple cylinder for knock prevention.
* External resilient rubber grommets for vibration isolation.
Two independent refrigerant circuits built up of * F class insulation class for compressor motor.
components and materials selected for compatibility, * 100 % suction gas cooled.
reliability and high efficiency. * Well-designed suction and discharge lines.
The two independent circuits design ensures partial * Built in oil pump
load operation.
CONDENSER MOTOR
- Insulated suction line with flexible synthetic rubber * Class F insulation
insulation, which has excellent thermal conductivity, * Three phase motor IP55.
high water diffusion and high sound absorption. * Drives blowers through adjustable pulleys..
- Filter driers fitted in liquid lines, efficiently remove CONDENSER COILS
moisture, scale, and solder particles and all types of Efficient and Tropicallized design:
foreign materials from refrigerant circuit. * Optimum condensing surfaces.
* Modified sine aluminum fins.
- Pumping down valves fitted in liquid lines to enable
* Optimum Number of coil circuits.
refrigerant to be temporaily stored in the condenser
* Cross counter Flow of refrigerant to air path.
coil if the refrigerant is to be repaired or some part of
* Full condensation with efficient liquid sub cooling.
the refrigeration system to be replaced
* Coils are leak tested at 450 PSI.
- Rotalock suction and discharge valves fitted on
CONDENSER BLOWERS
compressor for servicing.
* Double inlet centrifugal blowers with forward curved blades.
- The unit is completely factory assembled, electrically * Statically and dynamically balanced running in maintenance
wired, and charged with holding R22 charge, tested free bearings.
against extreme conditions and quality control
BLOWERS DRIVE
approved before leaving the factory.
- Belt drives with fixed pitch blower pulley and adjustable
OPTIONS motor pulley
- Head pressure control for unit operation at lower - All condenser blowers are factory set to give 100% nominal
ambient temperatures. pressure and airflow values and these may be field varied by
- Precoated aluminium fins for condenser coil means of adjustable pulley from 80% to 120% of nominal
values.

SUPER SAFETY PROTECTIONS


- Dual high/low pressure control for compressor protection
against high discharge, low suction pressures and
refrigerant leak.
- 4 minutes time delay for compressor protection against
short cycling when power off or thermostat off.
- 1 minute time delay for to avoid simultaneous starting of
both compressors for dual compressors units.
- Internal pressure relief valve for compressor protection
against high discharge pressures.
- Crankcase heater to guard compressor against flood back
conditions and to eliminate oil fluffing on start up
- Internal overloads for compressors and motors protection
against excessive temperature and/or excessive current.
- External sensitive quick trip overloads for compressors and
motors protection against excessive current.
These overloads mounted on definite purpose contactors of
quite operation.
- Voltage protector against low voltage, high voltage phase
reversal and phase loss.
All electrical components are UL approved and recognized.

4
GENERAL DESCRIPTION
EVAPORATOR UNIT
REFRIGERANT CIRCUIT EVAPORATOR MOTOR
- Entirely deoxidized dehydrated copper tubes with * Class F insulation
joints brazed by sliver brazing alloys. * Three phase motor IP55.
* Drives blowers through adjustable pulleys..
- For units 110, 145, 180 and 240 two independent
refrigerant circuits built up of components and EVAPORATOR COIL
materials selected for compatibility, reliability and Efficient design:
high efficiency. * Optimum evaporating surface.
The two independent circuits design ensures partial * Modified sine aluminum fins.
load operation. * Optimum Number of coil circuits.
* Cross counter Flow of refrigerant to air path.
- Insulated suction line with flexible synthetic rubber * Full evaporation with vapor superheating.
insulation, which has excellent thermal conductivity, * Coils are leak tested at 450 PSI.
high water diffusion and high sound absorption.
EVAPORATOR BLOWERS
- Self-regulating thermostatic expansion valves with
* Double inlet centrifugal blowers with forward curved blades.
external pressure equalizer in all units to control
* Statically and dynamically balanced running in maintenance free
refrigerant flow to evaporator coil.
bearings.
- A distributor ensures uniform supply of gas to the
evaporator coil. BLOWERS DRIVE
- Belt drives with fixed pitch blower pulley and adjustable
- The evaporator unit is completely factory assembled, motor pulley.
electrically wired, and charged with R22 holding - All evaporator blowers are factory set to give 100% nominal
charge, tested against extreme conditions and quality pressure and airflow values and these may be field varied by
control approved before leaving the factory. means of adjustable pulley from 80% to 120% of nominal
values.
ELECTRIC HEATER
AIR FILTERS
- Finned aluminum heating elements for efficient and - Long life, permanent and cleanable.
uniform heating. - Bonded EZ KLEAN aluminum filtering media with high dust
- VDE Standard. holding capacity for longer service life and increased overall
performance.
- Electric heaters include thermal protection, - Meets UL filter requirements.
contactors and all appropriate internal wiring.
THERMOSTAT
- The rating of heaters and number of stages available - Sensitive operates on 220V supply from the unit to the control
vary according to unit size. cooling, heating and fan operation.
- All units supplied with accessory thermostat and mounted
- Heater frame is constructed from galvanized steel and bracket.
powder painted with perfect adhesion of a highly
- The thermostat includes the following functions:
resistant polyester paint.
System : COOL- HEAT
SUPER SAFETY PROTECTIONS Fan : ON-AUTO
ON/OFF
- Temperature limiter protection for electric heater
against excessive heating temperatures in case of - For two stage thermostat:
malfunction of evaporator motor. The two stages of cooling make sequentially as the
- All electrical components are UL approved and temperature rises.
recognized. The two stages of heating make sequentially as the
temperature drops.
OPTIONS There is a differential between stages (interstage
- Conversion kit for evaporator vertical discharge. differential) so that the second stage makes only when
- Remote sensor up to 5 m for thermostat the first stage cannot handle the load.

5
TECHNICAL DATA
Vertical Packaged System Model 50UB-55 50UB-90 50UB-110 50UB-145 50UB-180 50UB-240
Condensing Unit Model 38BB-55 38BB-90 38BB-110 38BB-145 38BB-180 38BB-240
Split System
Evaporator Unit Model 40AB-55 40AB -90 40AB-110 40AB-145 40AB-180 40AB-240
Btu/hr 54.,500 85,700 109,000 144,000 171,000 230,000
Nominal Cooling Capacity*
Kw 15.98 25.12 31.97 42.20 50.12 67.41
Refrigerant
Type R22
Charge (Split System) Kg Holding
Total Charge (Vertical Packaged System) Kg 4.3 4.5 2 X 4.3 2 x 5.1 2 x 4.6 2 x 8.2
No. of Refrigerant Circuits 1 1 2 2 2 2
Refrigerant Control Expansion Valve
Refrigerant Lines
Suction : Diameter Qty 7/8 - 1 1-1/8 1 7/8 2 1-1/8 2 1-1/8 2 1-1/8 2
Liquid: Diameter Qty 1/2 - 1 1/2 - 1 1/2 - 2 1/2 - 2 1/2 - 2 5/8 - 2
Drain Line ID 3/4
Heating Capacity Kw 6 15 15 18 18 22.5

* Cooling Capacity, is based on the following conditions:


27/19C DBT/WBT Return Air to Indoor Evaporator Unit, 100% nominal Evap. Air Flow and 35C Outdoor Ambient Temperature.

ELECTRICAL DATA
Vertical Packaged 50UB-55 50UB-90 50UB-110 50UB-145 50UB-180 50UB-240
System Model 38BB-55 38BB-90 38BB-110 38BB-145 38BB-180 38BB-240
Split + 40AB-55 + 40AB-90 + 40AB-110 + 40AB-145 + 40AB-180 + 40AB-240
NOMINAL POWER SUPPLY V/3Ph/50Hz 380-420
Minimum Volts Maximum Volts 342-456 360-440 342-456 360-440 360-440 360-440
Kw (1) 7.25 11.2 14.5 19.4 21.0 34.9
Cooling Consumption
Amps (1) 13 23 26 41.5 43 60
Kw 6.75 16.1 16.5 20.2 20.2 26.5
Heating Consumption
Amps 11 25.5 26.2 32.2 32.2 34.5
Starting Current Amps 88 129 173 195 239 343
Mains Fuse Rating (2) Amps 25 40 50 80 80 100
Mains Power Switch (2) Amps 25 40 50 80 80 100
Wiring Section (3) mm 6 10 16 35 35 35
COMPRESSOR
Power Supply V/3Ph/50Hz 380-420
Minimum Volts 342 360 342 360 360 360
Maximum Volts 456 440 456 440 440 440
Locked Rotor Amperes (LRA) 62 78.5 62 80 78.5 130
Running Load Amperes (RLA) 8.2 15.7 8.2 12.8 15.7 25.7
Maximum Continuous Current (MCC) 16 22 16 18 22 36
CONDENSER MOTOR
Power Supply V/3Ph/50Hz 400 10 %
KW 1.5 2.2 3 3 3 4
HP 2 2.9 4 4 4 5.4
Full Load Amperes 3.5 4.9 6.5 6.5 6.5 8.3
EVAPORATOR MOTOR
Power Supply V/3Ph/50Hz 400 10 %
KW 0.75 1.1 1.5 2.2 2.2 4
HP 1 1.5 2 2.9 2.9 5.4
Full Load Amperes 1.9 2.7 3.5 4.9 4.9 8.3
ELECTRIC HEATER
Total Output Kw 6 15 15 18 18 22.5
Number of Heating Elements 6 6 6 6 6 9
Kw Per Heating Element 1 2.5 2.5 2.5 3 2.5
Number of Stages 1 1 2 2 2 2
Full Load Amperes 9.1 22.8 22.8 27.4 27.4 34.2
(1) Outdoor air temperature 35C db, Indoor air temperature 19C wb.

(2) Mains fuses and mains power switch are field installed.
The installer should place 3(Three) Fuses and 1 (One) mains isolator of capacities as shown in the table.

(3) The specified wiring section refers to copper conductors a 3-core cable having a maximum length of 20 meter.
For lengths exceeding 20 meter resize wires accordingly.

6
TECHNICAL DATA
CONDENSING UNIT
MODEL 38BB-55 38BB-90 38BB-110 38BB-145 38BB-180 38BB-240
COMPRESSOR
Power Supply V/3Ph/50Hz 380-420 380-420 380-420 380-420 380-420 380-420
Type HERMETIC
Quantity 1 1 2 2 2 2
R.P.M. at 50 Hz 2950
Protection Internal
Crankcase heater 220V/1PH
Quantity 1x30 1x35 2x30 2x35 2x35 2x35
Type PTCR
Minimum Volts 342 360 342 360 360 360
Maximum Volts 456 440 456 440 440 440
Locked Rotor Amperes (LRA) 62 78.5 62 80 78.5 130
Running Load Amperes (RLA) 8.2 15.7 8.2 12.8 15.7 27.7
Motor Cutout Current (MCC) 16 22 16 18 22 36
CONDENSER BLOWERS
Quantity 1 2 2 2 2 2
Nominal Air Flow m/hr 5250 9500 10,000 13,000 13,000 18,000
Air Flow Range m/hr 4200-6300 7600-11,400 8000-12,000 10,400-15,600 10,400-15,600 14,400-21,600
Type Centrifugal Double Inlet Forward Curved Blades
CONDENSER COIL
Total Face Area cm 4943 9000 9000 11,612 11,612 17,145
Number of Rows-Tube Diam. 5-3/8 4-3/8 5-3/8 5-3/8 5-3/8 6-1/2
Number of Fins per Inch 14 14 14 14 14 12
Type / Material Tubes-Fins Grooved / Copper Tubes Corrugated Aluminium Fins
CONDENSER MOTOR
Power Supply V/3Ph/50Hz 400 10 %
KW 1.5 2.2 3 3 3 4
HP 2 2.9 4 4 4 5.4
Full Load Amperes 3.5 4.9 6.5 6.5 6.5 8.3
BLOWER PULLEY
Type Fixed Pitch Cast Iron
Number of Grooves 1 2 2 2 2 2
External Diam./ Shaft Diam. mm 150/25 150/25 150/25 150/25 150/25 290/30
BELT
Quantity 1 2 2 2 2 2
Size A40 A41 A41 A71 A71 A80
MOTOR PULLEY
Type Adjustable Pitch Cast Iron
Number of Grooves 1 2 2 2 2 2
External Diam / Shaft Diam. mm 100/24 100/28 100/28 100/28 100/28 125/28
Width 890 1338 1338 1593 1593 2088
Height 1069 1165 1165 1405 1405 1405
DIMENSIONS (mm)
Depth 753 766 766 824 824 1060
Height with Feet 1169 1265 1265 1505 1505 1505
NET WEIGHT Kg 170 290 230 355 355 635
REFRIGERANT PIPING LINES
Suction: Diameter Qty 7/8 - 1 1-1/8 1 7/8 2 1-1/8 2 1-1/8 2 1-1/8 2
Liquid: Diameter Qty 1/2 - 1 1/2 1 1/2 - 2 1/2 - 2 1/2 - 2 5/8 - 2

7
TECHNICAL DATA
EVAPORATOR UNIT
MODEL 40AB-55 40AB 90 40AB-110 40AB-145 40AB-180 40AB-240
EVAPORATOR BLOWER
Quantity 1 2 2 2 2 2
Nominal Air Flow m/hr 3400 5100 6000 10,200 10,200 12,000
Air Flow Range m/hr 2750-4080 4080-6120 4800-7200 8160-12,240 8160-12,240 9600-14,400
Type Centrifugal Double Inlet - Forward Curved Blades
EVAPORATOR COIL
Total Face Area cm 3019 6451 6968 7742 7742 11,430
Number of Rows-Tube Diam. 4-3/8 4-3/8 5-3/8 4-3/8 4-3/8 5-1/2
Number of Fins per Inch 14 14 14 14 12 12
Type / Material Tubes-Fins Grooved / Copper Tubes Corrugated Aluminium Fins
REFRIGERANT
Type R22
EXPANSION DEVICE
Type Expansion Valve with External Equalizer
Quantity 1 1 2 2 2 2
EVAPORATOR MOTOR
Power Supply V/3Ph/50Hz 400 10 %
KW 0.75 1.1 1.5 2.2 2.2 4
HP 1 1.5 2 2.9 2.9 5.4
Full Load Amperes 1.9 2.7 3.5 4.9 4.9 8.3
BLOWER PULLEY
Type - Material Fixed Pitch Cast Iron
Number of Grooves 1 1 1 2 2 2
External Diam./ Shaft Diam. mm 125/20 125/20 125/20 125/20 125/20 175/20
MOTOR PULLEY
Type Adjustable Pitch Cast Iron
Number of Grooves 1 1 1 2 2 2
External Diam / Shaft Diam. mm 100/19 100/24 100/24 100/28 100/28 125/28
BELT
Quantity 1 1 1 2 2 2
Size A37-1/2 A38-1/2 A38-1/2 A42-1/2 A42-1/2 A32
ELECTRIC HEATER
Total Output Kw 5 15 15 18 18 22.5
Number oh Heating Elements 5 6 6 6 6 9
KW Per Heating Element 1 2.5 2.5 3 3 2.5
Number of Stages 1 1 2 2 2 2
Full Load Amperes 9.1 22.8 22.8 27.4 27.4 34.2
AIR FILTER
Type Washable Aluminum Air Filter
Width 890 1338 1338 1593 1593 2088
Height 536 663 663 792 792 654
DIMENSIONS (MM)
Depth 753 766 766 824 824 1060
Depth W/Heater 922.5 939.5 939.5 997 997 1234.5
NET WEIGHT Kg 85 125 140 205 205 310
REFRIGERANT PIPING LINES
Suction: Diameter Qty 7/8 - 1 1-1/8 1 7/8 2 1-1/8 2 1-1/8 2 1-1/8 2
Liquid: Diameter Qty 1/2 - 1 1/2 1 1/2 - 2 1/2 - 2 1/2 - 2 5/8 2

8
CONDENSER FAN PERFORMANCE DATA
If other static pressure and airflow combinations are required to balance ductwork, select condenser blower speed in
accordance with Fan Performance Table. All units are factory set to give 100% nominal flow and pressure values
and these may be varied by means of the adjustable motor pulley from 80% to 120% of the nominal.

AVAILABLE EXTERNAL STATIC PRESSURE CONDENSING UNIT

UNIT MOTOR AIRFLOW External Static Pressure mm. w. g.


SIZE HP 0 5 10 15 20 25
% M3/H RPM KW RPM KW RPM KW RPM KW RPM KW RPM KW
80 4,200 760 0.49 815 0.55 890 0.64 960 0.70 1.030 0.80 1.100 0.92

90 4,725 810 0.65 880 0.70 940 0.80 1.000 0.93 1.070 1.00 1.125 1.10

55 2 100 5,250 860 0.83 915 0.92 990 1.00 1.040 1.10 1.105 1.22 1.170 1.37

110 5,775 910 1.00 985 1.14 1.040 1.28 1.095 1.37 1.150 1.48 1.200 1.58

120 6,300 980 1.32 1.02 1.41 1.085 1.50 1.130 1.65 1.190 1.80 1.230 1.95

80 7,600 740 0.86 810 0.98 885 1.10 950 1.29 1.020 1.48 1.090 1.55

90 8,550 805 1.10 880 1.30 950 1.48 1.010 1.59 1.080 1.85 1.145 1.98

90 3 100 9,500 860 1.35 930 1.55 995 1.82 1.060 2.00 1.120 2.20 1.180 2.45

110 10,450 920 1.75 985 1.98 1.040 2.22 1.100 2.42 1.160 2.62 1.210 2.83

120 11,400 990 2.22 1.045 2.51 1.100 2.73 1.160 2.95 1.210 3.20 1.270 3.45

80 8,000 780 0.94 840 1.09 910 1.27 980 1.43 1.050 1.64 1.115 1.85

90 9,000 830 1.22 900 1.40 980 1.58 1.040 1.80 1.100 1.98 1.160 3.20

110 4 100 10,000 880 1.53 940 1.75 10.100 1.97 1.085 2.20 1.130 2.40 1.195 2.60

110 11,000 950 2.00 1.01 2.24 1.080 2.48 1.130 2.71 1.185 2.95 1.240 3.20

120 12,000 1.000 2.60 1.07 2.75 1.115 2.98 1.180 3.20 1.220 3.40 1.280 3.65

80 10,400 700 1.50 760 1.68 810 1.87 875 2.10 920 2.30 970 2.54

90 11,700 750 1.72 800 1.93 850 1.14 900 2.35 950 2.55 990 2.78

145-180 4 100 13,000 815 1.94 860 2.18 910 2.40 950 2.60 990 2.80 1.040 3.00

110 14,300 890 2.30 920 2.80 970 3.00 1.000 3.55 1.050 3.80 1.090 4.10

120 15,600 930 3.00 985 3.80 1.015 4.10 1.060 4.40 1.095 4.80 1.125 5.10

80 14,400 620 2.15 660 2.45 700 2.65 740 3.00 780 3.15 815 3.60

90 16,200 650 2.65 685 3.00 720 3.30 760 3.60 800 3.80 830 4.10

240 5.5 100 18,000 680 3.25 720 3.65 760 3.85 790 4.10 825 4.50 860 4.75

110 19,800 720 3.85 760 4.10 795 4.50 825 5.00 860 5.50 900 6.00

120 21,600 760 4.85 795 5.10 830 5.80 870 6.30 900 6.60 930 7.20

Motor of greater required 1 HP = 0.746 kW


Available static pressure include condenser coil casing pressure drop

9
EVAPORATOR FAN PERFORMANCE DATA
If other static pressure and airflow combinations are required to balance ductwork, select condenser blower speed in accordance
with Fan Performance Table. All units are factory set to give 100% nominal flow and pressure values and these may be varied by
means of the adjustable motor pulley from 80% to 120% of the nominal.

AVAILABLE EXTERNAL STATIC PRESSURE EVAPORATOR UNIT

UNIT MOTOR AIRFLOW External Static Pressure mm. w. g.


SIZE HP 0 5 10 15 20 25
% M3/H RPM KW RPM KW RPM KW RPM KW RPM KW RPM KW
80 2,750 750 0.21 850 0.26 930 0.32 1.020 0.37 1.095 0.45 1.190 0.50

90 3,060 815 0.31 900 0.35 995 0.43 1.060 0.47 1.140 0.52 1.225 0.59

55 1 100 3,400 895 0.40 990 0.48 1.060 0.51 1.120 0.58 1.200 0.65 1.275 0.74

110 3,740 960 0.50 1.040 0.56 1.105 0.63 1.180 0.70 1.230 0.75 1.300 0.88

120 4,080 1.040 0.65 1.105 0.74 1.180 0.83 1.240 0.90 1.300 0.96 1.360 1.03

80 4,080 710 0.24 825 0.34 915 0.44 1.025 0.55 1.110 0.69 1.215 0.76

90 4,590 750 0.32 850 0.43 950 0.51 1.040 0.64 1.120 0.74 1.220 0.92

90 1.5 100 5,100 800 0.43 890 0.51 985 0.63 1.070 0.74 1.160 0.88 1.240 1.00

110 5,610 860 0.55 940 0.68 1.030 0.77 1.100 0.92 1.190 1.05 1.275 1.18

120 6,120 900 0.66 990 0.80 1.075 0.93 1.140 1.07 1.215 1.18 1.290 1.33

80 4,800 810 0.39 900 0.50 1.000 0.62 1.085 0.73 1.180 0.86 1.260 0.97

90 5,400 880 0.54 960 0.68 1.045 0.77 1.120 0.92 1.210 1.03 1.285 1.15

110 2 100 6,000 920 0.70 1.010 0.81 1.090 0.93 1.170 1.05 1.240 1.21 1.310 1.38

110 6,600 990 0.89 1.060 1.00 1.130 1.10 1.210 1.28 1.280 1.43 1.340 1.55

120 7,200 1.050 1.08 1.110 1.22 1.190 1.34 1.250 1.48 1.310 1.65 1.380 1.85

80 8,160 720 0.85 790 1.02 860 1.15 920 1.33 955 1.50 1.065 1.05

90 9,180 795 1.16 860 1.35 920 1.50 990 1.73 1.060 1.90 1.120 2.15
145-
3 100 10,200 860 1.30 920 1.58 990 1.78 1.050 1.90 1.115 2.00 1.175 2.20
180
110 11,220 930 1.75 995 1.94 1.050 2.05 1.110 2.25 1.170 2.95 1.220 3.20

120 12,240 1.010 2.22 1.075 2.4 1.120 3.00 1.180 3.35 1.230 3.70 1.280 3.85

80 9,600 840 1.61 900 1.72 960 2.07 1.024 2.29 1.085 2.41 1.120 2.56

90 10,800 930 2.39 1.000 2.56 1.040 2.64 1.100 2.88 1.150 3.04 1.215 3.45

240 5.5 100 12,000 1.024 3.00 1.070 3.27 1.120 3.56 1.180 3.88 1.225 4.02 1.280 4.36

110 13,200 1.110 3.96 1.0160 4.10 1.210 4.42 1.260 4.71 1.300 5.06 1.350 5.17

120 14,400 1.220 4.94 1.260 5.29 1.315 5.75 1.345 6.03 1.400 6.32 1.440 6.89

Motor of greater required 1 HP = 0.746 kW


Available static pressure include condenser coil casing pressure drop

10
COOLING CAPACITIES (in KW)
UNIT SIZE: 55
EVAPORATOR AIR FLOW
EVAP. 3400
M3/h
ENTERING AIR
CONDENSER ENTERING
TEMPERATURE C 25 30 35 40 46 52
AIR TEMPERATURE C
WET DRY TOTAL CAPACITY KW 15.70 14.82 13.77 12.84 11.60 10.36
BULB BULB COMPRESSOR INPUT KW 4.40 4.75 5.10 5.45 5.87 6.29
18C 8.89 8.43 7.96 7.50 6.94 6.38
19C 9.70 9.24 8.77 8.31 7.75 7.19
20C 10.52 10.05 9.59 9.12 8.56 8.00
15C 21C SENSIBLE CAPACITY KW 11.33 10.70 10.40 9.94 9.38 8.82
22C 12.15 11.68 11.22 10.75 10.20 9.65
23C 12.96 12.50 12.03 11.58 11.01 10.46
24C 13.77 13.31 12.84 12.38 11.61 10.84
WET DRY TOTAL CAPACITY KW 16.68 15.93 14.88 13.77 12.59 11.41
BULB BULB COMPRESSOR INPUT KW 4.50 4.85 5.20 5.55 5.97 6.39
20C 8.95 8.48 8.02 7.55 7.00 6.45
21C 9.76 9.30 8.83 8.37 7.81 7.25
22C 10.58 10.11 9.65 9.20 8.62 8.04
17C 23C SENSIBLE CAPACITY KW 11.40 10.93 10.46 10.00 9.44 8.88
24C 12.20 11.74 11.27 10.81 10.25 9.69
25C 13.02 12.55 12.09 11.62 11.06 10.5
26C 13.83 13.37 12.90 12.44 11.88 11.32
WET DRY TOTAL CAPACITY KW 17.67 16.91 15.98 14.88 13.55 12.22
BULB BULB COMPRESSOR INPUT KW 4.6 4.95 5.30 5.65 6.07 6.49
22C 9.01 8.54 8.08 7.61 7.05 6.49
23C 9.82 9.31 8.90 8.42 7.87 7.32
24C 10.65 10.17 9.70 9.23 8.68 8.13
19C 25C SENSIBLE CAPACITY KW 11.45 10.98 10.51 10.04 9.49 8.94
26C 12.26 11.80 11.32 10.85 10.30 9.75
27C 13.08 12.61 12.13 11.66 11.11 10.56
28C 13.89 13.43 12.94 12.48 11.92 11.36
WET DRY TOTAL CAPACITY KW 13.25 17.73 16.86 15.75 14.43 13.11
BULB BULB COMPRESSOR INPUT KW 4.70 5.05 5.40 5.75 6.17 6.59
24C 9.06 8.60 8.13 7.67 7.11 6.55
25C 9.88 9.41 8.94 8.48 7.86 7.24
26C 10.70 10.23 9.75 9.29 8.67 8.05
21C 27C SENSIBLE CAPACITY KW 11.51 11.04 10.56 10.10 9.48 8.86
28C 12.32 11.86 11.37 10.92 10.32 9.72
29C 13.13 12.67 12.18 11.72 11.18 10.64
30C 13.95 13.31 12.99 12.53 12.00 11.47

NOTES:
1. 1 kW = 860 Kcal/H = 3412 BTU/H = 0.284 Ref. Tons.

2. Nominal total capacity and compressor input (at nominal evap. air flow and at nominal conditions: 27C DBT & 19C WBT
indoor air and 35C DBT outdoor air) are respectively 15.98 kW and 5.30 kW.

3. When Evap. air flow is different from nominal air flow, use following multipliers:

MULTIPLIER FOR Air flow Multi Air flow Multi Air flow Multi Air flow Multi Air flow Multi
Total Capacity 0.95 0.96 1.00 1.02 1.04
Compressor Input 2720 0.97 3060 0.98 3400 1.00 3740 1.02 4080 1.04
Sensible Capacity 0.86 0.91 1.00 1.04 1.06

COOLING CAPACITIES (in KW)


11
UNIT SIZE: 90
EVAPORATOR AIR FLOW
EVAP. 5100
M3/h
ENTERING AIR
CONDENSER ENTERING
TEMPERATURE C 25 30 35 40 46 52
AIR TEMPERATURE C
WET DRY TOTAL CAPACITY KW 25.56 23.60 21.76 19.86 17.58 15.30
BULB BULB COMPRESSOR INPUT KW 6.76 7.21 7.56 8.09 8.52 8.95
18C 15.76 14.62 13.48 12.34 10.97 9.60
19C 17.11 15.97 14.83 13.69 12.32 10.95
20C 18.46 17.32 16.18 15.04 13.67 12.30
15C
21C SENSIBLE CAPACITY KW 19.81 18.67 17.53 16.39 15.02 13.65
22C 21.16 20.02 18.88 17.74 16.37 15.00
23C 22.51 21.37 20.23 19.09 17.72 16.35
24C 23.86 22.72 21.58 20.44 19.07 17.70
WET DRY TOTAL CAPACITY KW 27.06 25.25 23.44 21.63 19.46 17.29
BULB BULB COMPRESSOR INPUT KW 6.91 7.35 7.70 8.24 8.73 9.22
20C 15.65 14.51 13.37 12.23 10.86 9.49
21C 17.00 15.86 14.72 13.58 12.21 10.84
22C 18.35 17.21 16.07 14.93 13.56 12.19
17C 23C SENSIBLE CAPACITY KW 19.70 18.56 17.42 16.28 14.91 13.54
24C 21.05 19.91 18.77 17.63 16.26 14.89
25C 22.40 21.26 20.12 18.98 17.61 16.24
26C 23.75 22.61 21.47 20.33 18.96 17.59
WET DRY TOTAL CAPACITY KW 28.56 26.84 25.12 23.40 21.34 19.28
BULB BULB COMPRESSOR INPUT KW 7.06 7.50 7.90 8.39 8.94 9.49
22C 15.54 14.40 13.26 12.12 10.75 9.38
23C 16.89 15.75 14.61 13.47 12.10 10.73
24C 18.24 17.10 15.96 14.82 13.45 12.08
19C 25C SENSIBLE CAPACITY KW 19.59 18.45 17.31 16.17 14.80 13.43
26C 20.94 19.80 18.66 17.52 16.15 14.78
27C 22.29 21.15 20.01 18.87 17.50 16.13
28C 23.64 22.50 21.36 20.22 18.85 17.48
WET DRY TOTAL CAPACITY KW 30.06 28.43 26.80 25.17 23.22 21.27
BULB BULB COMPRESSOR INPUT KW 7.22 7.65 8.05 8.55 9.15 9.75
24C 15.43 14.29 13.15 12.01 10.64 9.27
25C 16.78 15.64 14.50 13.36 11.99 10.62
26C 18.13 16.99 15.85 14.71 13.34 11.97
21C 27C SENSIBLE CAPACITY KW 19.48 18.34 17.20 16.06 14.69 13.32
28C 20.83 19.69 18.55 17.41 16.04 14.67
29C 22.18 21.04 19.90 18.76 17.39 16.02
30C 23.53 22.39 21.25 20.11 18.74 17.37

NOTES:
1. 1 kW = 860 Kcal/H = 3412 BTU/H = 0.284 Ref. Tons.

2. Nominal total capacity and compressor input (at nominal evap. air flow and at nominal conditions: 27C DBT & 19C WBT
indoor air and 35C DBT outdoor air) are respectively 25.12 kW and 7.90 kW.

3. When Evap. air flow is different from nominal air flow, use following multipliers:

MULTIPLIER FOR Air flow Multi Air flow Multi Air flow Multi Air flow Multi Air flow Multi
Total Capacity 0.95 0.97 1.00 1.04 1.06
Compressor Input 4080 0.97 4590 0.98 5100 1.00 5610 1.02 6120 1.03
Sensible Capacity 0.87 0.93 1.00 1.08 1.10

12
COOLING CAPACITIES (in KW)
UNIT SIZE: 110
EVAP. EVAPORATOR AIR FLOW
6000
ENTERING AIR M3/h
TEMPERATURE CONDENSER ENTERING
25 30 35 40 46 52
C AIR TEMPERATURE C
WET DRY TOTAL CAPACITY Kw 31.39 29.65 27.55 25.69 23.18 20.67
BULB BULB COMPRESSOR INPUT KW 8.80 9.50 10.20 10.90 11.74 12.58
18C 17.79 16.86 15.93 15.00 13.88 12.76
19C 19.41 18.48 17.55 16.62 15.51 14.40
20C 21.04 20.11 19.18 18.25 17.13 16.01
15C 21C SENSIBLE CAPACITY KW 22.67 21.74 20.81 19.88 18.76 17.64
22C 24.30 23.37 22.44 21.51 20.39 19.63
23C 25.93 25.00 24.06 23.13 22.02 20.91
24C 27.55 26.62 25.69 24.76 23.23 27.70
WET DRY TOTAL CAPACITY KW 33.37 31.86 29.76 27.55 25.18 22.81
BULB BULB COMPRESSOR INPUT KW 9.00 9.70 10.40 11.10 11.94 12.78
20C 17.90 16.97 16.04 15.11 14.00 12.89
21C 19.53 18.60 17.67 16.74 15.62 33.48
22C 21.16 20.23 19.30 18.37 17.25 16.13
17C 23C SENSIBLE CAPACITY KW 22.79 21.86 20.93 20.00 18.88 17.76
24C 24.41 23.48 22.55 21.62 20.51 19.40
25C 26.04 25.11 24.18 23.25 22.13 21.01
26C 27.67 26.74 25.81 24.88 23.76 22.64
WET DRY TOTAL CAPACITY KW 35.34 33.83 31.97 29.76 27.11 24.46
BULB BULB COMPRESSOR INPUT KW 9.20 9.90 10.60 11.30 12.14 12.98
22C 18.02 17.09 16.16 15.23 14.11 12.99
23C 19.65 18.72 17.79 16.85 15.74 14.63
24C 21.27 20.34 19.40 18.47 17.36 16.25
19C 25C SENSIBLE CAPACITY KW 22.90 21.97 21.03 20.09 18.98 17.87
26C 24.53 23.60 22.64 21.71 20.60 19.49
27C 26.16 25.23 24.64 23.23 22.22 21.21
28C 27.79 26.86 25.88 24.95 23.84 22.73
WET DRY TOTAL CAPACITY KW 36.51 35.46 33.72 31.51 28.86 26.57
BULB BULB COMPRESSOR INPUT KW 9.40 10.10 10.80 11.50 12.34 13.18
24C 18.13 17.20 16.27 15.34 14.23 13.12
25C 19.76 18.83 17.89 16.96 15.72 14.48
26C 21.39 20.46 19.51 18.58 17.34 16.10
21C 27C SENSIBLE CAPACITY KW 23.02 22.09 21.13 20.20 18.97 17.74
28C 24.65 23.72 22.75 21.82 20.60 21.30
29C 26.27 25.34 24.37 23.44 22.37 21.30
30C 27.90 26.62 25.99 25.06 24.00 22.94

NOTES:
1. 1 kW = 860 Kcal/H = 3412 BTU/H = 0.284 Ref. Tons.

2. Nominal total capacity and compressor input (at nominal evap. air flow and at nominal conditions: 27C DBT & 19C WBT
indoor air and 35C DBT outdoor air) are respectively 31.97 kW and 10.60 kW.

3. When Evap. air flow is different from nominal air flow, use following multipliers:

MULTIPLIER FOR Air flow Multi Air flow Multi Air flow Multi Air flow Multi Air flow Multi
Total Capacity 0.95 0.98 1.00 1.01 1.02
Compressor Input 4080 0.97 5400 0.98 6000 1.00 6600 1.01 7200 1.03
Sensible Capacity 0.87 0.93 1.00 1.02 1.13

COOLING CAPACITIES (in KW)


13
UNIT SIZE: 145
EVAPORATOR AIR FLOW
EVAP. 10200
M3/h
ENTERING AIR
CONDENSER ENTERING
TEMPERATURE C 25 30 35 40 46 52
AIR TEMPERATURE C
WET DRY TOTAL CAPACITY KW 42.32 40.34 37.90 35.34 32.27 29.20
BULB BULB COMPRESSOR INPUT KW 11.50 12.60 13.65 14.70 15.78 16.86
18C 24.18 23.19 22.20 21.20 20.03 18.86
19C 26.50 25.51 24.52 23.54 22.35 21.16
20C 28.82 27.83 26.84 25.86 24.67 23.48
15C 21C SENSIBLE CAPACITY KW 31.14 30.15 29.16 28.18 26.99 25.80
22C 33.46 32.47 31.48 30.50 29.31 28.57
23C 35.78 34.79 33.80 32.82 31.63 30.44
24C 38.10 37.11 36.12 35.14 33.95 32.76
WET DRY TOTAL CAPACITY KW 44.06 42.20 40.00 37.44 34.37 31.30
BULB BULB COMPRESSOR INPUT KW 11.80 12.90 13.95 15.00 16.08 17.16
20C 24.04 23.05 22.06 21.07 19.88 18.69
21C 26.36 25.37 24.38 23.39 22.20 20.01
22C 28.68 27.69 26.70 25.71 24.52 23.33
17C 23C SENSIBLE CAPACITY KW 31.00 30.01 29.02 28.03 26.84 25.65
24C 33.32 32.33 31.34 30.35 29.16 27.97
25C 35.64 34.65 33.66 32.67 31.48 30.29
26C 37.96 36.97 35.98 34.99 33.80 32.61
WET DRY TOTAL CAPACITY KW 45.58 44.06 42.09 39.53 36.46 33.39
BULB BULB COMPRESSOR INPUT KW 12.10 13.20 14.25 15.30 16.38 17.46
22C 23.89 22.90 21.91 20.93 19.74 18.55
23C 26.21 25.22 24.23 23.25 22.06 20.87
24C 28.53 27.54 26.55 25.57 24.38 23.19
19C 25C SENSIBLE CAPACITY KW 30.85 29.86 28.87 27.89 26.70 25.51
26C 33.17 32.18 31.19 30.21 29.02 27.83
27C 35.49 34.50 33.51 32.53 31.34 30.15
28C 37.81 36.82 25.83 34.85 33.66 32.47
WET DRY TOTAL CAPACITY KW 47.32 46.16 44.18 41.62 38.55 35.48
BULB BULB COMPRESSOR INPUT KW 12.40 13.50 14.50 15.60 16.68 17.76
24C 23.75 22.76 21.77 20.78 19.60 18.42
25C 26.07 25.08 24.09 23.10 21.92 20.74
26C 28.39 27.40 26.41 25.42 24.24 23.06
21C 27C SENSIBLE CAPACITY KW 30.71 29.72 28.73 27.74 26.56 25.38
28C 33.03 32.04 31.05 30.06 28.88 27.70
29C 35.35 34.36 33.37 32.38 31.20 30.12
30C 37.67 36.68 35.69 34.70 33.52 32.34

NOTES:
1. 1 kW = 860 Kcal/H = 3412 BTU/H = 0.284 Ref. Tons.

2. Nominal total capacity and compressor input (at nominal evap. air flow and at nominal conditions: 27C DBT & 19C WBT
indoor air and 35C DBT outdoor air) are respectively 52.09 kW and 14.25 kW.

3. When Evap. air flow is different from nominal air flow, use following multipliers:

MULTIPLIER FOR Air flow Multi Air flow Multi Air flow Multi Air flow Multi Air flow Multi
Total Capacity 0.95 0.95 1.00 1.03 1.05
Compressor Input 8160 0.96 9180 0.98 10200 1.00 11220 1.02 12240 1.04
Sensible Capacity 0.91 0.91 1.00 1.05 1.09

COOLING CAPACITIES (in KW)


14
UNIT SIZE: 180
EVAPORATOR AIR FLOW
EVAP. 10200
M3/h
ENTERING AIR
CONDENSER ENTERING
TEMPERATURE C 25 30 35 40 46 52
AIR TEMPERATURE C
WET DRY TOTAL CAPACITY Kw 53.58 49.54 45.86 42.37 38.78 35.19
BULB BULB COMPRESSOR INPUT kW 12.62 13.35 14.05 15.05 18.25 17.45
18C 31.48 29.10 26.72 24.34 21.49 18.46
19C 33.80 31.42 29.04 26.66 23.71 20.96
20C 36.12 33.74 31.36 28.98 28.13 23.28
15C 21C SENSIBLE CAPACITY KW 38.44 36.06 33.68 31.30 28.45 25.60
22C 40.76 38.38 36.00 33.62 30.77 27.92
23C 43.08 40.70 38.32 35.94 33.09 30.24
24C 45.40 43.02 40.64 38.26 35.41 32.56
WET DRY TOTAL CAPACITY KW 55.32 51.40 47.96 44.74 40.88 37.02
BULB BULB COMPRESSOR INPUT KW 12.92 13.65 14.35 15.35 16.55 17.75
20C 31.34 28.96 26.58 24.20 21.35 18.50
21C 33.66 31.28 28.90 26.52 23.67 20.82
22C 35.98 33.60 31.22 28.84 25.99 23.14
17C 23C SENSIBLE CAPACITY KW 38.30 35.92 33.54 31.16 28.31 25.46
24C 40.62 38.24 35.66 33.48 30.63 27.29
25C 42.94 40.56 38.18 35.80 32.95 30.10
26C 45.26 42.88 40.50 38.12 35.27 32.42
WET DRY TOTAL CAPACITY KW 56.84 53.26 50.05 46.83 42.97 39.11
BULB BULB COMPRESSOR INPUT KW 13.22 13.95 14.65 15.65 16.65 18.05
22C 31.20 28.82 26.44 24.06 21.21 18.36
23C 33.52 31.14 28.76 26.38 23.53 20.68
24C 35.84 33.48 31.08 28.70 25.85 23.00
19C 25C SENSIBLE CAPACITY KW 38.16 35.78 33.40 31.02 28.17 25.32
26C 40.48 38.10 35.72 33.34 30.49 27.64
27C 42.80 40.42 38.04 35.66 32.81 29.96
28C 45.12 42.74 40.36 37.98 35.13 32.28
WET DRY TOTAL CAPACITY KW 58.58 55.36 52.14 48.92 45.06 41.20
BULB BULB COMPRESSOR INPUT KW 13.52 14.25 14.95 15.95 17.15 18.35
24C 31.06 28.68 26.30 23.92 21.07 18.22
25C 33.38 31.00 28.62 26.24 23.39 20.54
26C 35.70 33.32 30.94 28.56 25.71 22.86
21C 27C SENSIBLE CAPACITYKW 38.02 35.64 33.26 30.88 28.03 25.18
28C 40.34 37.96 35.58 33.20 30.35 27.50
29C 42.66 40.28 37.90 35.52 32.67 29.82
30C 44.98 42.60 40.22 37.84 34.99 32.14

NOTES:
1. 1 kW = 860 Kcal/H = 3412 BTU/H = 0.284 Ref. Tons.

2. Nominal total capacity and compressor input (at nominal evap. air flow and at nominal conditions: 27C DBT & 19C WBT
indoor air and 35C DBT outdoor air) are respectively 50.05 kW and 14.65 kW.

3. When Evap. air flow is different from nominal air flow, use following multipliers:

MULTIPLIER FOR Air flow Multi Air flow Multi Air flow Multi Air flow Multi Air flow Multi
Total Capacity 0.95 0.95 1.00 1.03 1.05
Compressor Input 8160 0.96 9180 0.98 10200 1.00 11220 1.02 12240 1.04
Sensible Capacity 0.91 0.91 1.00 1.05 1.09

15
COOLING CAPACITIES (in KW)
UNIT SIZE: 240
EVAPORATOR AIR FLOW
EVAP. 12000
M3/h
ENTERING AIR
CONDENSER ENTERING
TEMPERATURE C 25 30 35 40 46 52
AIR TEMPERATURE C
WET DRY TOTAL CAPACITY KW 71.15 67.20 63.25 59.30 54.58 49.86
BULB BULB COMPRESSOR INPUT KW 21.60 23.10 24.70 26.40 28.60 30.80
18C 29.40 27.48 25.55 23.62 21.35 19.08
19C 34.12 32.20 30.30 28.37 26.10 23.83
20C 38.87 35.95 35.02 33.10 30.82 28.54
15C 21C SENSIBLE CAPACITY KW 43.60 41.68 39.78 37.85 35.58 33.31
22C 48.35 46.42 44.48 42.58 40.30 38.02
23C 53.07 51.15 49.25 47.32 45.06 42.80
24C 57.82 55.90 53.98 52.08 49.80 47.52
WET DRY TOTAL CAPACITY kW 72.68 68.96 65.00 61.06 55.32 51.58
BULB BULB COMPRESSOR INPUT KW 22.40 23.90 25.50 27.20 29.40 31.60
20C 29.46 27.52 25.60 23.70 21.42 19.14
21C 34.18 32.28 30.35 28.42 26.15 23.88
22C 38.92 37.00 35.08 33.18 30.90 28.62
17C 23C SENSIBLE CAPACITY KW 43.65 41.75 39.82 37.90 35.62 33.34
24C 48.40 46.48 44.58 42.65 40.37 38.09
25C 53.15 51.22 49.30 47.37 45.10 42.83
26C 57.88 55.95 54.05 52.12 49.85 47.58
WET DRY TOTAL CAPACITY KW 73.72 70.70 66.75 62.80 58.08 53.36
BULB BULB COMPRESSOR INPUT KW 23.20 24.70 26.30 28.00 30.20 32.40
22C 29.50 27.58 25.67 23.75 21.47 19.19
23C 34.25 32.32 30.40 28.50 26.22 23.94
24C 38.98 37.08 35.15 33.22 30.95 28.68
19C 25C SENSIBLE CAPACITY KW 43.72 41.80 39.87 37.97 35.70 33.43
26C 48.45 46.55 44.62 42.70 40.42 38.14
27C 53.20 51.28 49.35 47.45 45.17 42.89
28C 57.92 56.02 54.10 52.17 49.90 47.63
WET DRY TOTAL CAPACITY KW 74.78 72.45 68.50 64.52 59.80 66.08
BULB BULB COMPRESSOR INPUT KW 24.00 25.50 27.10 28.80 30.90 33.00
24C 29.58 27.55 25.72 23.80 21.52 19.24
25C 34.30 32.38 30.47 26.55 26.27 23.99
26C 39.06 37.12 35.20 33.27 31.00 28.73
21C 27C SENSIBLE CAPACITY KW 43.78 41.85 39.95 38.02 35.75 33.48
28C 48.52 46.60 44.67 42.75 40.47 38.19
29C 53.36 51.35 49.42 47.50 45.22 42.94
30C 58.00 56.08 54.15 52.22 49.95 47.68

NOTES:
1. 1 kW = 860 Kcal/H = 3412 BTU/H = 0.284 Ref. Tons.
2. Nominal total capacity and compressor input (at nominal evap. air flow and at nominal conditions: 27C DBT & 19C WBT
indoor air and 35C DBT outdoor air) are respectively 66.75 kW and 26.30 kW.
3. When Evap. air flow is different from nominal air flow, use following multipliers:

MULTIPLIER FOR Air flow Multi Air flow Multi Air flow Multi Air flow Multi Air flow Multi
Total Capacity 0.95 0.96 1.00 1.02 1.04
Compressor Input 9600 0.97 10800 0.98 12000 1.00 13200 1.02 14400 1.03
Sensible Capacity 0.90 0.94 1.00 1.04 1.09

DETAILED DIMENSIONS (IN MM)

16
VERTICAL PACKAGED SYSTEM
50UB 55
Evaporator Evaporator
Arrangement
Air Return Air Discharge
A Horizontal back Vertical
B Horizontal back Horizontal front

(A)

(B)

Evaporator Evaporator
Arrangement
Air Return Air Discharge
C Horizontal front Vertical
D Horizontal front Horizontal back

(C)

(D)

DETAILED DIMENSIONS (IN MM)

17
SPLIT SYSTEMS
CONDENSING UNIT
38BB - 55

EVAPORATOR UNIT
40AB - 55

(1)

Note (1): Field converted vertical air discharge for evaporator unit.

LOCATIONS AND DIAMETERS OF REFRIGERANT PIPING LINES


AND CONDENSATE DRAIN LINE

Refrigerant Piping Lines


and Drain Line
Size Line Qty
Suction 7/8
55 Liquid 1/2" 1
Drain 3/4"

18
DETAILED DIMENSIONS (IN MM)
VERTICAL PACKAGED SYSTEMS
50UB - 90 & 50UB - 110
Evaporator Evaporator
Arrangement
Air Return Air Discharge
A Horizontal back Vertical
B Horizontal back Horizontal front

(A) (A)

(B) (B)

Evaporator Evaporator
Arrangement
Air Return Air Discharge
C Horizontal front Vertical
D Horizontal front Horizontal back

(C) (C)

(D) (D)

19
DETAILED DIMENSIONS (IN MM)
SPLIT SYSTEMS
CONDENSING UNITS
38BB - 90 & 38BB - 110

EVAPORATOR UNITS
40AB - 90 & 40AB - 110

(1) (1)

Note (1): Field converted vertical air discharge for evaporator unit.

OUTLET LOCATIONS AND DIAMETERS


OF REFRIGERANT PIPING LINES
AND CONDENSATE DRAIN LINE

Size Line Qty


Suction 1-1/8
90 Liquid 1/2" 1
Drain 3/4"
Suction 7/8 2
110 Liquid 1/2" 2
Drain 3/4" 1

20
DETAILED DIMENSIONS (IN MM)
VERTICAL PACKAGED SYSTEMS
50UB - 145 & 50UB - 180
Evaporator Evaporator
Arrangement
Air Return Air Discharge
A Horizontal back Vertical
B Horizontal back Horizontal front

(A) (A)

(B) (B)

Evaporator Evaporator
Arrangement
Air Return Air Discharge
C Horizontal front Vertical
D Horizontal front Horizontal back

(C) (C)

(D) (D)

DETAILED DIMENSIONS (IN MM)


21
SPLIT SYSTEMS
CONDENSING UNITS
38BB - 145 & 38BB - 180

EVAPORATOR UNITS
40AB - 145 & 40AB - 180

(1) (1)

Note (1): Field converted vertical air discharge for evaporator unit.

OUTLET LOCATIONS AND DIAMETERS


OF REFRIGERANT PIPING LINES
AND CONDENSATE DRAIN LINE

Size Line Qty


Suction 1-1/8 2
145
180 Liquid 1/2" 2
Drain 3/4" 1

22
DETAILED DIMENSIONS (IN MM)
VERTICAL PACKAGED SYSTEMS
50UB - 240
Evaporator Evaporator
Arrangement
Air Return Air Discharge
A Horizontal back Vertical
B Horizontal back Horizontal front

(A) (A)

(B) (B)

Evaporator Evaporator
Arrangement
Air Return Air Discharge
C Horizontal front Vertical
D Horizontal front Horizontal back

(C) (C)

(D) (D)

DETAILED DIMENSIONS (IN MM)


23
SPLIT SYSTEM
CONDENSING UNIT
38BB - 240

EVAPORATOR UNIT
40AB - 240

(1) (1)

Note (1): Field converted vertical air discharge for evaporator unit.

OUTLET LOCATIONS AND DIAMETERS


OF REFRIGERANT PIPING LINES
AND CONDENSATE DRAIN LINE

Size Line Qty


Suction 1-1/8 2
240 Liquid 5/8" 2
Drain 3/4" 1

24