You are on page 1of 2
Head Office 39 Success Way, Henderson WASI65 T+61.89412 1500 ‘ato Branch 47 Proprietary Steet, Tingalpa QLD 4173. T461 733489177 Calbration & Sales 39 Success Way, Henderson WA 6166 T+61.89412 1500 Emailinfo@apts.comau ABNS9096934 815 www.aptscomau RADIOGRAPHIC INSPECTION REPORT Test Information Test Report No: | APTS-11851-03 Client Address: | 39 Lionel Street Date of Test: | 04/07/2017 Naval Base WA 6165, Client Request No: | 1083-02 Client Job No: | 1083-17 Client Contact: | Syed Rahman Glient P.0/Contract No: | 30039-10833 Leeroy Simon Location of Test: | APTS Workshop, Henderson Project: | Port Hedland Pipelines to Berth 1 Replacement Procedure No: | TM-41 ification: | N/A ‘AS/NZS 2885.2 — 2016 ‘Acceptance Criteria: | AS/NZS 2885.2 2016, Clause 22, Client: | GF Engineering Examination Method Buasi? LJASMEV-anicle2 —[Jothen — [Inspection Spe aan X-Ray Tube: | N/A ~]__kv/ma/Mins: | N/A Focal Spot (mm): | N/A Source Type: | SE 75 | Aetivity CU/Mins: | 68 ci Source Size (mm): | 2x2 Screens: | [X]Pb 0.027mm Llothers Film Type: | AGFA D4 | 1QIType/Location: | DINFE: 10 FEN Wire No,/Sensitvity: | 13, 14% Density: | 2.1-3.5 - Technique Z ml Weld Process: | L]smaw Dgrcaw Lleaw Biomaw Clsaw CJstr re jauto __[_JManual a Material Type: | Carbon Steel ae ‘Surface Condition: | DJAs Welded [_JOther(specify): | Surface Temperature: | Ambient Heat Treatment: | DQN/A___LJPre:___ JPost: - ‘Summary of Test: Radiographic Inspection was carried out as per request number 10833-02, evaluated and interpreted the films against the nominated code of acceptance criteria. Please see following page for results. Notes: ‘Approved Signatory: Leeroy Simon Level: AINDT Level2 e, Signature: <7 — Certification No.: 5374 , ‘Accredited for complionce with AS/SO IC 17025-Testng, The Oe ee a eae rests ofthe test calibration and/or measurements incloded in this document are traceable to hustralian/National Standards. This document sl nt be reproduced exept in fl Report Issued From: [2] wa Fait site No: 22880 Laboratory Aecedtaton No 14921 Report No: APTS-11851-08 [NDTF-06 NDT Radiographic Inspection Report, Rev 7, 15102/2017 Page tof? Head Office 39 Success Way, Henderson WA 6166 T¥6189412 1500 QuDeranch 47 Proprietary Street, Tingalpa QLO 4173. T4617 3348 9177 Calibration & Sales 39 Success Way, Henderson WA 6166. T+61 894121500 Emallinfo@aptscomau ABN59096934 815 www.aptscomau RADIOGRAPHIC INSPECTION REPORT Weld Spool/item ver DWE: 250-MP-01-050~ SHEET 4/2 250-MP-01-050-01A ‘Wi | wRi00 [250/9.27| _GFi88__| 0-860-0 Welder ID | DIA/SCH | WPS Area | Interpretation ws | weri00 |250/9.27| _GFigs | 0-860-0 DWG: 250-MP-O1-112 - SHEET 1/2 250-MP-01-112-01A\ 250/9.27 250/9.27 DWG: 250-MP-01-010 250-MP-01-010-018 250/9.27 250/9.27 '250/9.27 ‘Abbreviations (AS 4749) ] NO DRCONTINUTIE DETECTED [10 GABE NELSON TE ACKOFROOT RISO [Sas GROGAN Br tion re TUnesteninctson SS taccorsoeruson SA ROOT CONCANITY fe flowonteo oun Ke Graver Po: reoctsne treet Se Seamer cr Gasrone Ke ebonemen {oeauso roost Suce: Scennn unoercut we Hotlow sexo KE tbvenarupnacece [pu Unean ones SUCK IntemaL unoeRcur [ie comer nctuson i: Teaswenseonce Pu: Unione Rosie See Scie renernaion ie theanwetson 1. Uaexormmennnsuson ——/Ser- meonmerereuit ctove |e wom note |i ausiow [teen reneraon Ses: cxornaorruson fw WasONTRACRS- Si cc county one os war conn Report No: APTS-11851-03 [NOTF-06 NOT Radiographic Inspection Report, Rev 7, 15/02/2017 Page 202

You might also like