You are on page 1of 3

ECC 820 kVp/MA/mAs Meter

WARRANTY: 2-Years
SALES LEAD TIME: 5-7 Business Days
ACCESSORIES: Test Leads, Operator Manual, Calibration Certificate
CARRYING CASES: 800SC Padded Cordura Carrying Case for the 815 or 820 is an extra $50. 800HC
Hard Carrying Case for models 815 or 820 is an extra $75
GENERAL INFORMATION:

ECC recently announced the availability of a new multifunction meter, the model 820.

The new 820 kVp / mAs Meter combines all the features of our kVp, along with an mA / mAs meter in one
compact unit. The 820 is capable of measuring kVp, mA, mAs, and exposure time. The unit is self
resetting, and automatically detects AC or DC x-ray currents, minimizing the possibility of inaccurate
readings. With each mA reading, the unit stores and displays mA, mAs and exposure time. mA is sampled
for a representative length of time and saved. This allows shorter exposure times minimizing xray
exposure and wear and tear on the x-ray head. The Model 820 contains exactly the same kVp
measurement circuit and capability as our Model 815. The mA / mAs function has been squeezed into the
unit. The Model 820 is battery operated, user-friendly, and has a two year warranty. Applications include
verification of peak x-ray voltage, constancy checks, calibration of x-rays, and quality assurance
measurement of exposure time. The unit is also used for half value layer determination, troubleshooting
and repair of x-rays, and quality control.

The cable supplied with the unit serves as a switch. When the cable is plugged into the unit, it is
automatically configured for mA readings. When the cable is unplugged the Model 820 functions as a kVp
meter.

The introduction of the Model 820 allows service personnel to carry one instrument rather than an mAs
Meter and a kVp Meter.

kVp SPECIFICATIONS FOR THE 815/820


RANGE

815/820: 45 to 125 kV
815L/820L: 40 to 115 kV

KVP ACCURACY

2% 1 kV, at 25 to 100 mA for 815, at 10 to 50 mA for 815L


18 to 42 cm from head, for Tungsten target x-ray tube with 1.5 mm Al equivalent filtration

EXPOSURE TIME ACCURACY

1% 2 millisecond (1/5 to 2 sec)


Minimum exposure time is 100 milliseconds

MINIMUM EXPOSURE TIME (kVp Measurement)

100 millisec - High Speed Mode (normal)


200 millisec - High Resolution Mode

MINIMUM CURRENT (mA)

7 mA at 50 kV, 10 cm from x-ray source


Also depends on focus / collimating

mA / mAs SPECIFICATIONS FOR THE 820


RANGE

200 mA Full Scale


mA Resolution (mA or mAs)

10 Ohms Input Impedance

2A Full Scale Range selection via pushbutton at power on

o 1 mA Resolution (mA or mAs)

o 1 Ohm Input Impedance

ACCURACY

2% 1 mA on both ranges
CONNECTION

Via 1 meter cable with two alligator clips


Connecting cable switches meter to mA /mAs

GENERAL SPECIFICATIONS FOR THE 815/820


DISPLAY

0.4"(10.2mm) Liquid Crystal


8 Character Alphanumeric

POWER

4 AA Batteries accessible from bottom of case

Low Battery Indicator

BATTERY LIFE

48 hours continuous
Typically 9 months of normal use

CONTROLS/ INDICATORS

ON/OFF Switch - Illuminated push-button with green power-on indication


MODE Switch - Momentary push-button
8 Character Liquid Crystal Display

PHYSICAL SIZE

150 x 120 x 58.5 mm


5.9 x 4.7 x 2.3 inches

WEIGHT

0.7 kG (1.5 lb)