Professional Documents
Culture Documents
Please visit us at E
Cartridge Valves &
L Integrated Circuit
www.deltrolfluid.com
T Manifolds
for information on these other Deltrol product lines: R
Hydraulic Integrated Circuit Manifolds O
In-Line Flow Control, Needle, Check and Accessory Valves
Custom Solutions for Your Fluid Power and Fluid Control Demands L
P
R
O
Valve Specialists D
to the Fluid Power Industry. U
C
T
S
www.deltrolfluid.com
ISO 9001:2008
CERTIFIED
World Class
Performance
Design Delivery
Our design group is divided into two cross-functional teams, Our MRP based manufacturing system gives us the flexibility
which allows us to focus on product designs that meet our to meet our customers delivery system requirements. We
customers requirements. The valve design group can are experienced in working with various customer
develop valves independently or integrate with our systems implementations of pull order systems. We work closely to
design group based on customers special applications and understand our customers ERP systems and have the
needs. Our three-dimensional modeling software enables us flexibility to integrate our packaging and delivery with their
to create the most compact and efficient solutions for our requirements.
customers.
We take pride in our ability to provide high quality, cost effective customer solutions. We offer a wide range of
standard products and excel at the opportunity to modify our current designs or develop unique products that
meet our customers special needs.
If the solution you need is not available in our catalog or you have a special application, please contact us so we
can develop a component or system that meets your specific demands. Whether its a unique environment, flow
media, fit, or application, we are eager to work with you to provide products and services that make you most
competitive in your marketplace.
03/11
0.01.1
TOC 3/6/11 11:42 PM Page 1
Table of Contents
0.00.0 INTRODUCTION
Flow Pressure
Model Series Page
gpm lpm psi bar
5.0 18.9 4000 276 DSV-080-2NCP-*-M Series 8 1.01.3
Flow Pressure
Model Series Page
gpm lpm psi bar
3.0 11.4 3000 207 DSV2-080-2NCS Series 8 1.14.1
6.0 22.7 3000 207 DSV2-100-2NCS Series 10 1.15.1
01/11
0.02.1
TOC 3/6/11 11:42 PM Page 2
(continued)
Flow Pressure
Model Series Page
gpm lpm psi bar
3.0 11.4 3000 207 DSV2-080-2NOS Series 8 1.16.1
6.0 22.7 3000 207 DSV2-100-2NOS Series 10 1.17.1
Flow Pressure
Model Series Page
gpm lpm psi bar
4.0 15.1 3000 207 DSV2-080-3 Series 8 1.20.1
6.0 22.7 3000 207 DSV2-100-3 Series 10 1.21.1
Flow Pressure
Model Series Page
gpm lpm psi bar
5.0 18.9 3000 207 DSV2-080-3B Series 8 1.23.1
6.0 22.7 3000 207 DSV2-100-3B Series 10 1.24.1
Flow Pressure
Model Series Page
gpm lpm psi bar
6.0 22.7 3000 207 DSV2-100-3D Series 10 1.26.1
Flow Pressure
Model Series Page
gpm lpm psi bar
3.0 11.4 3000 207 DSV2-080-4NC Series 8 1.30.1
6.0 22.7 3000 207 DSV2-100-4NC Series 10 1.31.1
01/11
0.02.2
TOC 3/6/11 11:42 PM Page 3
Table of Contents
(continued)
Flow Pressure
Model Series Page
gpm lpm psi bar
3.0 11.4 3000 207 DSV2-080-4CO Series 8 1.32.1
6.0 22.7 3000 207 DSV2-100-4CO Series 10 1.33.1
Flow Pressure
Model Series Page
gpm lpm psi bar
3.0 11.4 3000 207 DSV2-080-4TC Series 8 1.34.1
Flow Pressure
Model Series Page
gpm lpm psi bar
3.0 11.4 3000 207 DSV2-080-4N0 Series 8 1.36.1
Flow Pressure
Model Series Page
gpm lpm psi bar
3.0 11.4 3000 207 DSV-080-34M Series 8 1.40.1
6.0 22.7 3000 207 DSV-100-34M Series 10 1.41.1
Flow Pressure
Model Series Page
gpm lpm psi bar
1.5 5.7 3000 207 DSV-100-34TR Series 10 1.43.3
01/11
0.02.3
TOC 3/6/11 11:42 PM Page 4
(continued)
Flow Pressure
Model Series Page
gpm lpm psi bar
1.5 5.7 3000 207 DSV-080-34O Series 8 1.46.1
3.0 11.4 3000 207 DSV-100-34O Series 10 1.47.1
Flow Pressure
Model Series Page
gpm lpm psi bar
8.0 30.3 3000 207 DPV-100-2NC Series 10 1.80.1
2.00.0 CHECK
Check, Direct-Acting
Flow Pressure
Model Series Page
gpm lpm psi bar
1.0 3.8 3500 241 ZCO-42 Zero Profile 2.01.1
5.0 19.0 3500 241 ZCP6 Zero Profile 2.03.1
4.0 15.2 3000 207 ZC-62 Zero Profile 2.07.1
2.0 7.6 1500 103 ZCO-62 Zero Profile 2.08.1
5.0 18.9 3000 207 DCV-080-B Series 8 2.09.1
20.0 75.7 3000 207 DCV-100-B Series 10 2.10.1
5.0 18.9 3000 207 DCV-080-PB Series 8 2.11.1
20.0 75.7 3000 207 DCV-100-PB Series 10 2.12.1
10.0 37.9 3000 207 DCV-100-P Series 10 2.14.1
01/11
0.02.4
TOC 3/6/11 11:42 PM Page 5
Table of Contents
(continued)
Check, Pilot-To-Close
Flow Pressure
Model Series Page
gpm lpm psi bar
3.0 11.4 4000 276 ZPTC-63 Zero Profile 3.08.1
12.0 45.4 3000 207 DPTC-100-P Series 10 3.09.1
01/11
0.02.5
TOC 3/6/11 11:42 PM Page 6
(continued)
Flow Pressure
Model Series Page
gpm lpm psi bar
10.0 37.9 3000 207 PCM 88 In-Line 4.13.1
Flow Pressure
Model Series Page
gpm lpm psi bar
24.0 90.8 3000 207 LLPC In-Line 4.14.1
Flow Pressure
Model Series Page
gpm lpm psi bar
2.0 7.6 3000 207 DFRA-080-2 Series 8 4.24.1
10.0 37.9 3000 207 DFRA-100-2 Series 10 4.26.1
Flow Pressure
Model Series Page
gpm lpm psi bar
10.0 37.9 3000 207 DFR-100-3 Series 10 4.30.1
25.0 94.6 3000 207 DFR-120-3 Series 12 4.32.1
01/11
0.02.6
TOC 3/6/11 11:42 PM Page 7
Table of Contents
(continued)
Flow Pressure
Model Series Page
gpm lpm psi bar
16.0 60.6 3000 207 DFD-100 Series 10 4.40.1
5.00.0 RELIEF
Flow Pressure
Model Series Page
gpm lpm psi bar
2.0 11.4 3000 207 ZRV-63 Zero Profile 5.01.1
10.0 37.9 3000 207 DRV2-080 Series 8 5.02.1
10.0 37.9 3000 207 DRV-080-*-H Series 8 5.03.1
10.0 37.9 3000 207 DRV-100 Series 10 5.04.1
Flow Pressure
Model Series Page
gpm lpm psi bar
5.0 18.9 3000 207 ZDRV-63 Zero Profile 5.05.1
10.0 37.9 3000 207 DDRV-080 Series 8 5.06.1
10.0 37.9 3000 207 DDRV-080-*-H Series 8 5.07.1
20.0 75.7 3600 248 DDRV-100 Series 10 5.08.1
Flow Pressure
Model Series Page
gpm lpm psi bar
20.0 75.7 5000 345 DP0R-080 Series 8 5.09.1
30.0 113.6 3000 207 DP0R-100 Series 10 5.10.1
01/11
0.02.7
TOC 3/6/11 11:43 PM Page 8
(continued)
Flow Pressure
Model Series Page
gpm lpm psi bar
16.0 60.6 5500 380 RV-050 Series 050 5.12.1
20.0 75.7 5000 345 RV-060 Series 060 5.12.3
24.0 90.8 5000 345 RV-080 Series 080 5.12.5
Flow Pressure
Model Series Page
gpm lpm psi bar
15.0 56.8 3600 248 DBRV-100 Series 10 5.13.1
20.0 75.7 5000 345 DBRV2-100-*-H Series 10 5.14.1
Flow Pressure
Model Series Page
gpm lpm psi bar
8.0 30.3 4000 276 DRVK-080 Series 8 5.20.1
Flow Pressure
Model Series Page
gpm lpm psi bar
5000 345 ZTRV-62 Zero Profile 5.30.1
Flow Pressure
Model Series Page
gpm lpm psi bar
4.0 15.1 3000 207 DPR-100 Series 10 6.02.1
Flow Pressure
Model Series Page
gpm lpm psi bar
5.0 18.9 5000 345 DPRR-080 Series 8 6.03.1
01/11
0.02.8
TOC 3/6/11 11:43 PM Page 9
Table of Contents
(continued)
7.00.0 SEQUENCE
Flow Pressure
Model Series Page
gpm lpm psi bar
6.0 22.7 3000 207 DPS-100 Series 10 7.02.1
Flow Pressure
Model Series Page
gpm lpm psi bar
6.0 22.7 5000 345 DPS3-080 Series 8 7.04.3
Flow Pressure
Model Series Page
gpm lpm psi bar
5.0 18.9 4000 276 DPSK-080 Series 8 7.04.7
5.0 18.9 3000 207 DPSK-100 Series 10 7.05.1
5.0 18.9 3000 207 DPSK2-100 Series 10 7.06.1
01/11
0.02.9
TOC 3/6/11 11:43 PM Page 10
(continued)
8.00.0 SHUTTLE
Shuttle, Ball-Type
Flow Pressure
Model Series Page
gpm lpm psi bar
4.0 15.2 3000 207 ZSHB-63 Zero Profile 8.02.1
6.0 22.7 3000 207 DSH-100 Series 10 8.05.1
Flow Pressure
Model Series Page
gpm lpm psi bar
6.0 22.7 3000 207 DMP-080-2NCP Series 8 9.01.1
Flow Pressure
Model Series Page
gpm lpm psi bar
6.0 22.7 3000 207 DTV-080 Series 8 9.03.1
Flow Pressure
Model Series Page
gpm lpm psi bar
6.0 22.7 3000 207 DTV2-080 Series 8 9.04.1
Flow Pressure
Model Series Page
gpm lpm psi bar
5.0 18.9 3000 207 DMR2-080 Series 8 9.05.1
Flow Pressure
Model Series Page
gpm lpm psi bar
5.0 18.9 3000 207 DMO-080-2NCSP Series 8 9.07.1
01/11
0.02.10
TOC 3/6/11 11:43 PM Page 11
Table of Contents
(continued)
Flow Pressure
Model Series Page
gpm lpm psi bar
8.0 30.4 3000 207 DPOD-100-2NCP Series 10 9.10.1
Flow Pressure
Model Series Page
gpm lpm psi bar
10.0 38.9 3000 207 DPOD-100-2NOP Series 10 9.12.1
10.00.0 ACCESSORIES
Flow Pressure
Model Series Page
gpm lpm psi bar
3000 207 DHP2-100 Series 10 10.01.1
Flow Pressure
Model Series Page
gpm lpm psi bar
3000 207 DHP-100 Series 10 10.02.1
01/11
0.02.11
TOC 3/6/11 11:43 PM Page 12
(continued)
Recommended Filtration................................................................................................................................11.01.1
01/11
0.02.12
TOC 3/6/11 11:43 PM Page 13
Notes
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:31 PM Page 5
03/11
0.03.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:31 PM Page 6
DSV-080-2NCP
Normally-Closed, Two-Way, Two-Position,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
A cartridge valve designed with positive shut off to be used in load
holding applications.
CONTROL
MOTION
OPERATION
When de-energized, the DSV-080-2NCP acts as a check valve,
CONTROL
To return to normal operation, push button in, twist clockwise and release.
Override will be detented in this position. Note: Pull only to override and
release to return option available. See page 1.01.3
PRESSURE
CONTROL
SPECIFICATIONS
DIRECTIONAL
VALVES
100 (6.9) Minimum Pull-In Voltage: 85% of rated voltage at 4000 PSI (276 Bar)
Response Time: 80% of final change of state with 100% voltage
75 (5.2)
supplied at 100% of nominal flow rating.
50 (3.4) Pull-In: 12 VDC 16 m. sec. Drop-Out: 12 VDC 18 m. sec.
Recommended Filtration: Critical Application-ISO 17/15/13
TECHNICAL
25 (1.7)
Non-Critical Application-ISO 20/18/14
DATA
1.01.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:31 PM Page 7
DSV-080-2NCP
Normally-Closed, Two-Way, Two-Position,
SOLENOID
Pilot-Operated Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
.19
(4.8)
OPEN
CONTROL
MOTION
.19
(4.8) MANUAL
OPEN OVERRIDE
OPTION
.75 (19.0) HEX.
TORQUE 40 IN.-LBS. 4.60
CONTROL
(4.5 Nm) MAX. (116.8)
FLOW
2.60
(66.0)
1.88 3.88
(47.8) (98.6) .59
RELIEF
(15.0)
1.50
(38.1) 2.00
.88 (22.4) HEX. (50.8)
TORQUE 20 FT.-LBS.
1.08 (27.1 Nm) MAX.
PRESSURE
(27.4)
CONTROL
FILTER .28 TYP.
250 NOM. MICRON (7.1)
(EFFECTIVE FROM 1.25
TO ONLY) .56
(31.8) (14.2)
.13 1.63 1.13
(3.3) (41.4) (28.7)
2.00
SEQUENCE
(50.8)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV - 080 - 2 NC P - * - * * - * * * * - **
SOLENOID PORTING
VALVE 2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
CAVITY/SEAL 4T = SAE 4
6T = SAE 6
FLOW PATH Omit for Cartridge Only
NORMALLY CLOSED
COIL CONNECTION
POPPET DE = Double Lead
ACCESSORIES
SE = Single Lead
HS = Hirschmann
SEALS
CS = Conduit
N = Buna N
BE = Double Spade
V = Viton
EE = Single Stud
M = Manual Override
UE = Deutsch
(Omit for standard)
See page 1.01.3 for additional options.
VOLTAGE
TECHNICAL
1.01.2
DSV-080-2NCP-*-M* (Pull-Type
Manual Override)
SOLENOID
Pilot-Operated Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV - 080 - 2 NC P - * - M* - * * * * - **
SOLENOID PORTING
VALVE 2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
CAVITY/SEAL 4T = SAE 4
6T = SAE 6
FLOW PATH Omit for Cartridge Only
NORMALLY CLOSED
COIL CONNECTION
POPPET DE = Double Lead
ACCESSORIES
SE = Single Lead
SEALS HS = Hirschmann
N = Buna N CS = Conduit
V = Viton BE = Double Spade
EE = Single Stud
M = Manual Override UE = Deutsch
See page 1.01.1 for additional options.
1.01.4
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:31 PM Page 8
DSV-080-2NCP-*-M* (Pull-Type
Manual Override)
SERIES 8
CHECK
DESCRIPTION
A cartridge valve designed with positive shut off to be used in load
CONTROL
holding applications.
MOTION
OPERATION
CONTROL
FLOW
Continuous-duty solenoid.
Hardened poppet and plunger for long life and low leakage.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
Filter screen standard.
SHUTTLE
SPECIFICATIONS
TO (ENERGIZED)
Operating Pressure: 4000 PSI (276 Bar)
TO (DE-ENERGIZED)
150 ssu/32 cSt OIL @ 100F/38C Flow: See PRESSURE DROP VS. FLOW graph
125(8.6)
Internal Leakage: 5 drops/min. max. at 4000 PSI (276 Bar)
Temperature: -30 F to +250 F (-35C to +120 C)
ACCESSORIES
1.01.3
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:31 PM Page 10
DSV2-100-2NCP
Normally-Closed, Two-Way, Two-Position,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
holding applications.
MOTION
OPERATION
CONTROL
FLOW
Continuous-duty solenoid.
Hardened poppet and plunger for long life and low leakage.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
Filter screen standard.
SHUTTLE
SPECIFICATIONS
PRESSURE DROP VS. FLOW Operating Pressure: 3000 PSI (207 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
Internal Leakage: 5 drops/min. max. at 3000 PSI (207 Bar)
Temperature: -30 F to +250 F (-35C to +120 C)
ACCESSORIES
1.03.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:31 PM Page 11
DSV2-100-2NCP
Normally-Closed, Two-Way, Two-Position,
SOLENOID
Pilot-Operated Solenoid Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 100 - 2 NC P - * - * - * * * - **
SOLENOID PORTING
VALVE 2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
CAVITY/SEAL
6T = SAE 6
8T = SAE 8
FLOW PATH
Omit for Cartridge Only
NORMALLY CLOSED
COIL CONNECTION
D = Double Lead
POPPET
ACCESSORIES
S = Single Lead
H = Hirschmann
SEALS C = Conduit
N = Buna N B = Double Spade
V = Viton E = Single Stud
M = Manual Override
(Omit for standard) VOLTAGE
1 = 12 Volt 6 = 240 Volt
TECHNICAL
2 = 24 Volt 9 = 20 Volt
DATA
1.03.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:31 PM Page 12
DSV2-080-2NOP
Normally-Open, Two-Way, Two-Position,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
holding applications.
MOTION
OPERATION
CONTROL
FLOW
Continuous-duty solenoid.
Hardened poppet and plunger for long life and low leakage.
Efficient wet-armature construction.
SEQUENCE
SPECIFICATIONS
10152-80 03/11
1.08.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:31 PM Page 13
DSV2-080-2NOP
Normally-Open, Two-Way, Two-Position,
SOLENOID
Poppet-Type Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.75 (19.1) HEX
TORQUE 40 IN.-LBS.
(4.5 Nm ) MAX.
CONTROL
FLOW
2.16
(54.9)
4.16
(105.7) .59
(15.0)
1.50
RELIEF
(38.1) 2.00
.88 (22.4) HEX. (50.8)
TORQUE 20 FT.-LBS.
1.08 (27.1 Nm) MAX.
(27.4) .28 TYP.
PRESSURE
CONTROL
FILTER (7.1)
250 NOM. MICRON
(EFFECTIVE FROM 1.25
TO ONLY) .56
(31.8) (14.2)
.13 1.63 1.13
(3.3) (41.4) (28.7)
2.00
(50.8)
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 080 - 2 NO P - * - * * * * - **
SOLENOID PORTING
VALVE 2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
CAVITY/SEAL 4T = SAE 4
6T = SAE 6
FLOW PATH
Omit for Cartridge Only
NORMALLY OPEN
COIL CONNECTION
POPPET DE = Double Lead
ACCESSORIES
SE = Single Lead
SEALS HS = Hirschmann
N = Buna N CS = Conduit
V = Viton BE = Double Spade
EE = Single Stud
D = DC UE = Deutsch
A = AC
VOLTAGE
TECHNICAL
2 = 24 Volt 9 = 20 Volt
Omit coil for cartridge only with nut. 5 = 120 Volt 10 = 10 Volt
Other porting and coil options available consult factory.
1.08.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:31 PM Page 14
DSV2-080-2NOP-*-M (Push-Type
Manual Override)
SERIES 8
CHECK
DESCRIPTION
holding applications.
MOTION
OPERATION
flow from to .
Continuous-duty solenoid.
Hardened poppet and plunger for long life and low leakage.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
Filter screen standard.
SHUTTLE
10227-57(2) 03/11
1.08.3
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:31 PM Page 15
DSV2-080-2NOP-*-M (Push-Type
Manual Override)
SOLENOID
Poppet-Type Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.75 (19.1) HEX
TORQUE 40 IN.-LBS.
(4.5 Nm ) MAX.
CONTROL
FLOW
3.50
(88.9) 5.47
(138.9)
RELIEF
.59
(15.0)
1.50
(38.1) 2.00
.88 (22.4) HEX. (50.8)
TORQUE 20 FT.-LBS.
1.08 (27.1 Nm) MAX.
PRESSURE
CONTROL
(27.4)
FILTER .28 TYP.
250 NOM. MICRON (7.1)
(EFFECTIVE FROM
TO ONLY) 1.25 .56
(31.8) (14.2)
.13 1.63 1.13
(3.3) (41.4) (28.7)
SEQUENCE
2.00
(50.8)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 080 - 2 NO P - * - M - * * * * - **
SOLENOID PORTING
VALVE 2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
CAVITY/SEAL 4T = SAE 4
6T = SAE 6
FLOW PATH
Omit for Cartridge Only
NORMALLY OPEN
COIL CONNECTION
POPPET DE = Double Lead
ACCESSORIES
SE = Single Lead
HS = Hirschmann
SEALS
CS = Conduit
N = Buna N
M = MANUAL OVERRIDE BE = Double Spade
V = Viton
EE = Single Stud
UE = Deutsch
D = DC
A = AC VOLTAGE
TECHNICAL
2 = 24 Volt 9 = 20 Volt
5 = 120 Volt 10 = 10 Volt
Omit coil for cartridge only with nut.
Other porting and coil options available consult factory.
1.08.4
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 16
DSV2-100-2NOP
Normally-Open, Two-Way, Two-Position,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
holding applications.
MOTION
OPERATION
CONTROL
FLOW
Continuous-duty solenoid.
Hardened poppet and plunger for long life and low leakage.
Efficient wet-armature construction.
SEQUENCE
SPECIFICATIONS
10148-98 03/11
1.09.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 17
DSV2-100-2NOP
Normally-Open, Two-Way, Two-Position,
SOLENOID
Poppet-Type Solenoid Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 100 - 2 NO P - * - * * * - **
SOLENOID PORTING
VALVE 2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
CAVITY/SEAL 6T = SAE 6
FLOW PATH 8T = SAE 8
Omit for Cartridge Only
NORMALLY OPEN
COIL CONNECTION
POPPET D = Double Lead
ACCESSORIES
S = Single Lead
SEALS H = Hirschmann
N = Buna N C = Conduit
V = Viton B = Double Spade
E = Single Stud
D = DC
A = AC VOLTAGE
1 = 12 Volt 6 = 240 Volt
TECHNICAL
2 = 24 Volt 9 = 20 Volt
DATA
1.09.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 18
DSV-080-2NCSP
Normally-Closed, Two-Way, Two-Position,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
Continuous-duty solenoid.
Hardened poppet and seat for long life and low leakage.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
SEQUENCE
SPECIFICATIONS
Minimum Pull-In Voltage: 85% of rated voltage at 3000 PSI (207 Bar)
Response Time: 80% of final change of state with 100% voltage
PRESSURE DROP psi (bar)
150 (10.3)
supplied at 100% of nominal flow rating.
Pull-In: 12 VDC 41 m. sec. Drop-Out: 12 VDC 30 m. sec.
100 (6.9)
Recommended Filtration: Critical Application ISO 17/15/13
Non-Critical Application ISO 20/18/14
50 (3.4)
Fluids: Mineral-based fluids. For other fluid compatibility, consult factory.
TECHNICAL
0
0 1.0 2.0 3.0 4.0 5.0 In-Line Body Material: Anodized 6061T6 aluminum
(3.8) (7.6) (11.4) (15.1) (18.9)
alloy rated at 3000 PSI (207 Bar).
FLOW gpm (L/min.)
10138-34 03/11
1.11.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 19
DSV-080-2NCSP
Normally-Closed, Two-Way, Two-Position,
SOLENOID
Bi-Directional Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MANUAL
MOTION
OVERRIDE 1.31
OPTION MB (33.3) .88 (22.4) HEX.
TORQUE 40 IN.-LBS.
(4.5 Nm) MAX.
3.03
CONTROL
(77.0)
FLOW
2.72
(69.1)
4.72
(119.9)
RELIEF
.59
.88 (22.4) HEX. (15.0)
TORQUE 20 FT.-LBS. 1.50
1.09 (27.1 Nm) MAX.
(27.7) (38.1) 2.00
(50.8)
PRESSURE
CONTROL
.28 TYP.
NOTE:
(7.1)
DUE TO PERFORMANCE REQUIRE- 1.25
MENTS, THIS SIZE 8 VALVE .56
USES SIZE 10 COIL ASSEMBLES. (31.8) (14.2)
.13 1.63 1.13
(41.4) (28.7)
SEQUENCE
(3.3)
2.00
(50.8)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV - 080 - 2 NC SP - * - ** - * - * * * - **
SOLENOID PORTING
VALVE 2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
CAVITY/SEAL 4T = SAE 4
6T = SAE 6
FLOW PATH Omit for Cartridge Only.
NORMALLY CLOSED
COIL CONNECTION
BI-DIRECTIONAL D = Double Lead
S = Single Lead
ACCESSORIES
SEALS H = Hirschmann
N = Buna C = Conduit
V = Viton B = Double Spade
E = Single Stud
Manual Override
U = Deutsch
M = Push and Twist
MB = Push
(Omit for standard) VOLTAGE
TECHNICAL
1.11.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 20
DSV2-080-2NCS
Normally-Closed, Two-Way, Two-Position,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
OPERATION
When energized, the cartridges spool shifts to allow flow in either direction.
To return to normal operation, push button in, twist clockwise and release.
PRESSURE
SPECIFICATIONS
10183-40 03/11
1.14.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 21
DSV2-080-2NCS
Normally-Closed, Two-Way, Two-Position,
SOLENOID
Spool-Type Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 080 - 2 NC S - * - * - * * * * - **
SOLENOID PORTING
VALVE 2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
CAVITY/SEAL 4T = SAE 4
6T = SAE 6
FLOW PATH Omit for Cartridge Only
NORMALLY CLOSED
COIL CONNECTION
SPOOL DE = Double Lead
ACCESSORIES
SE = Single Lead
SEALS HS = Hirschmann
N = Buna N CS = Conduit
V = Viton BE = Double Spade
EE = Single Stud
UE = Deutsch
M = Manual Override
(Omit for standard) VOLTAGE
TECHNICAL
D = DC 2 = 24 Volt 9 = 20 Volt
Omit coil for cartridge only with nut. A = AC 5 = 120 Volt 10 = 10 Volt
Other porting and coil options available consult factory.
1.14.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 22
DSV2-100-2NCS
Normally-Closed, Two-Way, Two-Position,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
OPERATION
When energized, the cartridges spool shifts to allow flow in either direction.
To return to normal operation, push button in, twist clockwise and release.
PRESSURE
- (ENERGIZED)
PRESSURE
1
DROP VS. FLOW Manual override option.
Industry common cavity.
TO OR TO (ENERGIZED)
150 ssu/32 cSt OIL @ 100F/38C Compact size.
50 (3.5)
40 (2.8)
DIRECTIONAL
VALVES
30 (2.1)
SPECIFICATIONS
20 (1.4)
Operating Pressure: 3000 PSI (207 Bar)
10 (.7)
Flow: See PERFORMANCE CHARACTERISTIC graph.
0 Internal Leakage: 5 in. 3/min. (82 cc/min.) max. at 3000 PSI (207 Bar)
0.5 1.0 1.5 2.0 2.5 3.0
0
(1.9) (3.8) (5.7) (7.6) (9.5) (11.4) Temperature: -30 F to +250 F (-35C to +120 C)
ACCESSORIES
FLOW gpm (L/min.) Coil Rating: Continuous from 85% to 110% of rated voltage.
Current Draw: 12 VDC is 1.8 amps.
PERFORMANCE CHARACTERISTIC Minimum Pull-In Voltage: 85% of rated voltage at 3000 PSI (207 Bar)
150 ssu/32 cSt OIL @ 100F/38C Recommended Filtration: ISO 17/15/13
Fluids: Mineral-based fluids. For other fluid compatibility consult factory.
3000 (206.9)
Cavity/Cavity Tool: 100-2, see page 11.10.2
In-Line Body Material: Anodized 6061T6 aluminum
TECHNICAL
2000 (137.9)
1000 (69.0)
0
0 1.0 2.0 3.0 4.0 5.0 6.0
(3.8) (7.6) (11.4) (15.1) (18.9) (22.7)
FLOW gpm (L/min.)
10167-81 03/11
1.15.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 23
DSV2-100-2NCS
Normally-Closed, Two-Way, Two-Position,
SOLENOID
Spool-Type Solenoid Valve
SERIES 10
CHECK
.10
INSTALLATION DIMENSIONS (2.5)
OPEN
CONTROL
MOTION
MANUAL
.10 OVERRIDE
(2.5) OPTION
OPEN
.88 (22.4) HEX.
TORQUE 40 IN.-LBS.
(4.5 Nm) MAX.
CONTROL
FLOW
5.24
(133.1)
3.24 4.45
(82.3) (113.0)
RELIEF
2.45
(62.2) .75
(19.0)
1.50
(38.1) 2.00
(50.8)
PRESSURE
CONTROL
1.00 (25.4) HEX.
TORQUE 30 FT.-LBS .28 TYP.
1.25 (7.1)
(40.7 Nm) MAX.
(31.8)
1.25
.63
(16.0)
(31.8)
1.63 1.25
.13 (31.8)
(41.4)
SEQUENCE
(3.3)
2.00
(50.8)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 100 - 2 NC S - * - * - * * * - **
SOLENOID PORTING
VALVE 2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
CAVITY/SEAL 6T = SAE 6
FLOW PATH 8T = SAE 8
Omit for Cartridge Only
NORMALLY CLOSED
COIL CONNECTION
SPOOL D = Double Lead
ACCESSORIES
S = Single Lead
H = Hirschmann
SEALS
C = Conduit
N = Buna N
B = Double Spade
V = Viton
E = Single Stud
M = Manual Override
(Omit for standard) VOLTAGE
TECHNICAL
2 = 24 Volt 9 = 20 Volt
D = DC 5 = 120 Volt 10 = 10 Volt
Omit coil for cartridge only with nut. A = AC
Other porting and coil options available consult factory.
1.15.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 24
DSV2-080-2NOS
Normally-Open, Two-Way, Two-Position,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
A cartridge valve designed to operate as a bi-directional blocking valve.
CONTROL
MOTION
OPERATION
When energized, the cartridges spool shifts to block flow in either direction.
SPECIFICATIONS
150 ssu/32 cSt OIL @ 100F/38C Coil Rating: Continuous from 85% to 110% of rated voltage.
100 (6.9)
Current Draw: 12 VDC is 1.3 amps.
PRESSURE DROP psi (bar)
80 (5.5) Minimum Pull-In Voltage: 85% of rated voltage at 3000 PSI (207 Bar)
60 (4.1)
Response Time: 80% of final change of state with 100% voltage
supplied at 100% of nominal flow rating.
40 (2.8) Pull-In: 12 VDC 85 m. sec. Drop-Out: 12 VDC 95m. sec.
Recommended Filtration: ISO 17/15/13
TECHNICAL
20 (1.4)
Fluids: Mineral-based fluids. For other fluid compatibility consult factory.
DATA
0
Cavity/Cavity Tool: 080-2, see page 11.08.2
0 0.5
(1.9)
1.0
(3.8)
1.5
(5.7)
2.0
(7.6)
2.5
(9.5)
3.0
(11.4) In-Line Body Material: Anodized 6061T6 aluminum
FLOW gpm (L/min.) alloy rated at 3000 PSI (207 Bar).
10181-20 03/11
1.16.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 25
DSV2-080-2NOS
Normally-Open, Two-Way, Two-Position,
SOLENOID
Spool-Type Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
.07
(1.8)
OPEN
CONTROL
MOTION
.07 MANUAL
(1.8) OVERRIDE
OPEN OPTION
CONTROL
(4.5 Nm) MAX.
FLOW
2.75 4.75
(69.9) (120.7)
1.88
(47.8) 3.88
.59
RELIEF
(98.6)
(15.0)
1.50
(38.1) 2.00
.88 (22.4) HEX. (50.8)
TORQUE 20 FT.-LBS.
1.09
PRESSURE
(27.1 Nm) MAX.
CONTROL
(27.7) .28 TYP.
(7.1)
1.25 .56
(31.8) (14.2)
.13 1.63 1.13
(3.3) (41.4) (28.7)
SEQUENCE
2.00
(50.8)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 080 - 2 NO S - * - * - * * * * - **
SOLENOID PORTING
VALVE 2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
CAVITY/SEAL 4T = SAE 4
6T = SAE 6
FLOW PATH Omit for Cartridge Only
NORMALLY OPEN
COIL CONNECTION
SPOOL DE = Double Lead
ACCESSORIES
SE = Single Lead
SEALS HS = Hirschmann
N = Buna N CS = Conduit
V = Viton BE = Double Spade
EE = Single Stud
UE = Deutsch
M = Manual Override
(Omit for standard) VOLTAGE
TECHNICAL
D = DC 2 = 24 Volt 9 = 20 Volt
Omit coil for cartridge only with nut. A = AC 5 = 120 Volt 10 = 10 Volt
Other porting and coil options available consult factory.
1.16.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 26
DSV2-100-2NOS
Normally-Open, Two-Way, Two-Position,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
A cartridge valve designed to operate as a bi-directional blocking valve.
CONTROL
MOTION
OPERATION
When energized, the cartridges spool shifts to block flow in either direction.
80(5.5)
DIRECTIONAL
60(4.1)
VALVES
SPECIFICATIONS
40(2.8)
FLOW gpm(L/min.)
Coil Rating: Continuous from 85% to 110% of rated voltage.
Current Draw: 12 VDC is 1.8 amps.
PERFORMANCE CHARACTERISTIC
Minimum Pull-In Voltage: 85% of rated voltage at 3000 PSI (207 Bar)
150 ssu/32 cSt OIL @ 100F/38C
Recommended Filtration: ISO 17/15/13
PRESSURE DROP psi (bar)
3000(206.9)
to
to
Fluids: Mineral-based fluids. For other fluid compatibility consult factory.
Cavity/Cavity Tool: 100-2, see page 11.10.2
2000(137.9) In-Line Body Material: Anodized 6061T6 aluminum
TECHNICAL
to
to alloy rated at 3000 PSI (207 Bar).
DATA
1000(69.0)
0
0 1.0 2.0 3.0 4.0 5.0 6.0
(3.8) (7.6) (11.4) (15.1) (18.9) (22.7)
FLOW gpm(L/min.)
10167-82 03/11
1.17.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 27
DSV2-100-2NOS
Normally-Open, Two-Way, Two-Position,
SOLENOID
Spool-Type Solenoid Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 100 - 2 NO S - * - * - * * * - **
SOLENOID PORTING
VALVE 2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
CAVITY/SEAL 6T = SAE 6
FLOW PATH 8T = SAE 8
Omit for Cartridge Only
NORMALLY OPEN
COIL CONNECTION
SPOOL D = Double Lead
ACCESSORIES
S = Single Lead
SEALS H = Hirschmann
N = Buna N C = Conduit
V = Viton B = Double Spade
E = Single Stud
2 = 24 Volt 9 = 20 Volt
DATA
1.17.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 28
DDSV-080-2NCP
Normally-Closed, Two-Way, Two-Position,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
methods of operation.
OPERATION
CONTROL
FLOW
Compact size.
SPECIFICATIONS
DIRECTIONAL
VALVES
1.18.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 29
DDSV-080-2NCP
Normally-Closed, Two-Way, Two-Position,
SOLENOID
Dual-Coil, Pilot Operated Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DDSV - 080 - 2 NC P - * - * * - * * * * - **
SOLENOID PORTING
VALVE 2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
CAVITY/SEAL 6T = SAE 6
8T = SAE 8
FLOW PATH Omit for Cartridge Only
NORMALLY CLOSED
COIL CONNECTION
POPPET DE = Double Lead
ACCESSORIES
SE = Single Lead
SEALS HS = Hirschmann
N = Buna N CS = Conduit
V = Viton BE = Double Spade
EE = Single Stud
M = Manual Override UE = Deutsch
(Omit for standard)
L = Low Leak Option VOLTAGE
TECHNICAL
D = DC 2 = 24 Volt 9 = 20 Volt
Omit coil for cartridge only with nut. A = AC 5 = 120 Volt 10 = 10 Volt
Other porting and coil options available consult factory.
1.18.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 30
DSV2-080-3
Three-Way, Two-Position,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
control valve.
MOTION
OPERATION
CONTROL
FLOW
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
SHUTTLE
SPECIFICATIONS
1.20.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 31
DSV2-080-3
Three-Way, Two-Position,
SOLENOID
Spool-Type Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS .07
(1.8)
OPEN
CONTROL
MOTION
.07 MANUAL
(1.8) OVERRIDE
OPEN OPTION
.75 (19.1) HEX.
CONTROL
TORQUE 40 IN.-LBS.
FLOW
(4.5 Nm) MAX. 4.51
(114.6)
5.38
2.75 .61 (136.7)
(69.9) (15.5) 1.17
1.88 (29.7)
RELIEF
(47.8)
2.13
(54.1) 2.63
(66.8)
.88 (22.4) HEX.
PRESSURE
TORQUE 20 FT.-LBS.
CONTROL
1.59 (27.1 Nm) MAX.
.28 TYP.
(40.4)
(7.1)
1.25 .56
(31.8) (14.2)
.25 2.00 1.13
(6.4) 2.50
(50.8) (28.7)
SEQUENCE
(63.5)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 080 - 3 - * - * - * * * * - **
SOLENOID PORTING
VALVE 2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
CAVITY/SEAL 4T = SAE 4
FLOW PATH 6T = SAE 6
Omit for Cartridge Only
D = DC VOLTAGE
TECHNICAL
2 = 24 Volt 9 = 20 Volt
Omit coil for cartridge only with nut. 5 = 120 Volt 10 = 10 Volt
Other porting and coil options available consult factory.
1.20.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 32
DSV2-100-3
Three-Way, Two-Position,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
control valve.
MOTION
OPERATION
CONTROL
FLOW
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
SHUTTLE
SPECIFICATIONS
1.21.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 33
DSV2-100-3
Three-Way, Two-Position,
SOLENOID
Spool-Type Solenoid Valve
SERIES10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 100 - 3 - * - * - * * * - **
SOLENOID PORTING
VALVE 2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
CAVITY/SEAL 6T = SAE 6
FLOW PATH 8T = SAE 8
Omit for Cartridge Only
VOLTAGE
D = DC 1 = 12 Volt 6 = 240 Volt
TECHNICAL
A = AC 2 = 24 Volt 9 = 20 Volt
DATA
1.21.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 34
DSV2-080-3B
Three-Way, Two-Position,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
control valve.
MOTION
OPERATION
CONTROL
FLOW
Continuous-duty solenoid.
SEQUENCE
Compact size.
SPECIFICATIONS
DIRECTIONAL
VALVES
0
In-Line Body Material: Anodized 6061T6 aluminum
0 1
(3.8)
2
(7.6)
3
(11.4)
4
(15.1)
5
(18.9)
alloy rated at 3000 PSI (207 Bar).
10181-08 03/11
1.23.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 35
DSV2-080-3B
Three-Way, Two-Position,
SOLENOID
Spool-Type Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS .07
(1.8)
OPEN
CONTROL
MOTION
.07 MANUAL
(1.8) OVERRIDE
OPEN OPTION
.75 (19.1) HEX.
CONTROL
TORQUE 40 IN.-LBS.
FLOW
(4.5 Nm) MAX. 4.51
(114.6)
5.38
2.75 .61 (136.7)
(69.9) (15.5)
1.88 1.17
RELIEF
(29.7)
(47.8)
2.13
(54.1) 2.63
(66.8)
.88 (22.4) HEX.
PRESSURE
CONTROL
TORQUE 20 FT.-LBS.
1.59 (27.1 Nm) MAX.
.28 TYP.
(40.4)
(7.1)
1.25 .56
(31.8) (14.2)
.25 2.00 1.13
(6.4) 2.50
(50.8) (28.7)
SEQUENCE
(63.5)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 080 - 3B - * - * - * * * * - **
SOLENOID PORTING
VALVE
DIRECTIONAL
2N = 1/4 PTF
3N = 3/8 PTF
VALVES
4T = SAE 4
CAVITY/SEAL 6T = SAE 6
Omit for Cartridge Only.
SE = Single Lead
SEALS HS = Hirschmann
N = Buna N CS = Conduit
V = Viton BE = Double Spade
EE = Single Stud
UE = Deutsch
M = Manual Override
(Omit for standard) VOLTAGE
TECHNICAL
D = DC 2 = 24 Volt 9 = 20 Volt
A = AC 5 = 120 Volt 10 = 10 Volt
Omit coil for cartridge only with nut.
Other porting and coil options available consult factory.
1.23.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 36
DSV2-100-3B
Three-Way, Two-Position,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
control valve.
MOTION
OPERATION
CONTROL
FLOW
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
Manual override option.
SHUTTLE
SPECIFICATIONS
VALVES
10186-30 03/11
1.24.1
DSV2-100-3B
Three-Way, Two-Position,
SOLENOID
Spool-Type Solenoid Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimetersrs
HOW TO ORDER
SHUTTLE
DSV2 - 100 - 3B - * - * - * * * - **
SOLENOID PORTING
VALVE
DIRECTIONAL
2N = 1/4 PTF
3N = 3/8 PTF
VALVES
4T = SAE 4
CAVITY/SEAL 6T = SAE 6
Omit for Cartridge Only.
S = Single Lead
SEALS H = Hirschmann
N = Buna N C = Conduit
V = Viton B = Double Spade
E = Single Stud
M = Manual Override
(Omit for standard)
VOLTAGE
TECHNICAL
D = DC 2 = 24 Volt 9 = 20 Volt
A = AC 5 = 120 Volt 10 = 10 Volt
Omit coil for cartridge only with nut.
Other porting and coil options available consult factory.
1.24.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 38
DSV2-100-3D
Three-Way, Two-Position,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
control valve.
MOTION
OPERATION
CONTROL
FLOW
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
SHUTTLE
SPECIFICATIONS
1.26.1
DSV2-100-3D
Three-Way, Two-Position,
SOLENOID
Spool-Type Solenoid Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 100 - 3D - * - * - * * * - **
SOLENOID PORTING
VALVE
DIRECTIONAL
2N = 1/4 PTF
3N = 3/8 PTF
VALVES
6T = SAE 6
CAVITY/SEAL 8T = SAE 8
Omit for Cartridge Only.
S = Single Lead
SEALS H = Hirschmann
N = Buna N C = Conduit
V = Viton B = Double Spade
E = Single Stud
M = Manual Override
(Omit for standard) VOLTAGE
TECHNICAL
D = DC 2 = 24 Volt 9 = 20 Volt
A = AC 5 = 120 Volt 10 = 10 Volt
Omit coil for cartridge only with nut.
Other porting and coil options available consult factory.
1.26.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 40
DSV2-080-4NC
Four-Way, Two-Position,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
control valve with all ports normally-closed. This valve is commonly used
MOTION
OPERATION
CONTROL
FLOW
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
SHUTTLE
SPECIFICATIONS
PRESSURE DROP VS. FLOW
Operating Pressure: 3000 PSI (207 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
Internal Leakage: (Per land) 5 in.3/min. (82 cc/min.) max. at
3000 PSI (207 Bar)
ACCESSORIES
1.30.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 41
DSV2-080-4NC
Four-Way, Two-Position,
SOLENOID
Spool-Type Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
.07
(1.8)
OPEN
CONTROL
MOTION
.07
(1.8) MANUAL
OPEN OVERRIDE
OPTION
.75 (19.1) HEX.
TORQUE 40 IN.-LBS.
CONTROL
(4.5 Nm) MAX.
2.75
FLOW
(69.9)
1.88 6.00
.61 (152.4)
(47.8) (15.5) 1.17
(29.7)
RELIEF
1.73
5.13
.88 (22.4) HEX. (43.9) (130.3)
TORQUE 20 FT.-LBS.
(27.1 Nm) MAX. 2.88 3.25
(73.2) (82.6)
PRESSURE
2.15
CONTROL
(54.6)
.28 TYP.
(7.1) 1.25 .56
(31.8) (14.2)
.25 2.00 1.13
SEQUENCE
(6.4) (50.8) (28.7)
2.50
(63.5)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 080 - 4 NC - * - * - * * * * - **
SOLENOID PORTING
VALVE 2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
4T = SAE 4
CAVITY/SEAL 6T = SAE 6
Omit for Cartridge Only.
SE = Single Lead
NORMALLY CLOSED HS = Hirschmann
CS = Conduit
BE = Double Spade
SEALS EE = Single Stud
N = Buna N UE = Deutsch
V = Viton
M = Manual Override VOLTAGE
TECHNICAL
D = DC 2 = 24 Volt 9 = 20 Volt
Omit coil for cartridge only with nut. A = AC 5 = 120 Volt 10 = 10 Volt
Other porting and coil options available consult factory.
1.30.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 42
DSV2-100-4NC
Four-Way, Two-Position,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
control valve with all ports normally-closed. This valve is commonly used
MOTION
OPERATION
CONTROL
FLOW
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
SHUTTLE
SPECIFICATIONS
TO (ENERGIZED)
Temperature: -30F to +250F (-35C to +120C)
150 ssu/32 cSt OIL @ 100F/38C
160 (11.0) Coil Rating: Continuous from 85% to 110% of rated voltage.
PRESSURE DROP psi (bar)
0
0 2.0 4.0 6.0
Fluids: Mineral-based fluids. For other fluid compatibility, consult factory.
(7.6) (15.1) (22.7) Cavity/Cavity Tool: 100-4, see page 11.10.4
FLOW gpm (L/min.) In-Line Body Material: Anodized 6061T6 aluminum
alloy rated at 3000 PSI (207 Bar).
10186-27 03/11
1.31.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 43
DSV2-100-4NC
Four-Way, Two-Position,
SOLENOID
Spool-Type Solenoid Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 100 - 4 NC - * - * - * * * - **
SOLENOID PORTING
VALVE 2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
6T = SAE 6
CAVITY/SEAL 8T = SAE 8
Omit for Cartridge Only.
D = DC 2 = 24 Volt 9 = 20 Volt
Omit coil for cartridge only with nut. A = AC 5 = 120 Volt 10 = 10 Volt
Other porting and coil options available consult factory.
1.31.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 44
DSV2-080-4CO
Four-Way, Two-Position,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
control valve with all ports normally-open. This valve is commonly used
MOTION
OPERATION
CONTROL
FLOW
to and from to .
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
SHUTTLE
SPECIFICATIONS
PRESSURE DROP VS. FLOW Operating Pressure: 3000 PSI (207 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
Internal Leakage: (Per land)5 in.3/min. (82 cc/min.) max.at 3000 PSI (207 Bar)
ACCESSORIES
1.32.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 45
DSV2-080-4CO
Four-Way, Two-Position,
SOLENOID
Spool-Type Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
.07
(1.8)
CONTROL
MOTION
OPEN
.07 MANUAL
(1.8) OVERRIDE
OPEN OPTION
.75 (19.0) HEX.
TORQUE 40 IN.-LBS.
(4.5 Nm) MAX.
CONTROL
FLOW
2.75
(69.9)
1.88 6.00
(47.8) .61 (152.4)
(15.5) 1.17
(29.7)
RELIEF
1.73 5.13
(130.3)
.88 (22.4) HEX. (43.9)
TORQUE 20 FT.-LBS.
(27.1 Nm) MAX. 2.88 3.25
(73.2) (82.6)
2.15
PRESSURE
CONTROL
(54.6)
.28 TYP.
(7.1) 1.25 .56
(14.2)
.25 2.00 (31.8) 1.13
(50.8)
SEQUENCE
(6.4) 2.50 (28.7)
(63.5)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 080 - 4 CO - * - * - * * ** - **
PORTING
SOLENOID 2N = 1/4 PTF
VALVE 3N = 3/8 PTF
DIRECTIONAL
4T = SAE 4
VALVES
6T = SAE 6
CAVITY/SEAL Omit for Cartridge Only.
FLOW PATH
COIL CONNECTION
ar) DE = Double Lead
ACCESSORIES
SE = Single Lead
CROSSOVER
HS = Hirschmann
CS = Conduit
BE = Double Spade
SEALS
EE = Single Stud
N = Buna N
UE = Deutsch
V = Viton
M = Manual Override VOLTAGE
TECHNICAL
2 = 24 Volt 9 = 20 Volt
D = DC 5 = 120 Volt 10 = 10 Volt
Omit coil for cartridge only with nut. A = AC
Other porting and coil options available consult factory.
1.32.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 46
DSV2-100-4CO
Four-Way, Two-Position,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
control valve with all ports normally-open. This valve is commonly used
MOTION
OPERATION
CONTROL
FLOW
to and from to .
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
SHUTTLE
SPECIFICATIONS
PRESSURE DROP VS. FLOW Operating Pressure: 3000 PSI (207 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
Internal Leakage: (Per land)5 in.3/min. (82 cc/min.) max.at 3000 PSI (207 Bar)
ACCESSORIES
1.33.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 47
DSV2-100-4CO
Four-Way, Two-Position,
SOLENOID
Spool-Type Solenoid Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 100 - 4 CO - * - * - * * * - **
PORTING
SOLENOID
DIRECTIONAL
2N = 1/4 PTF
VALVE
VALVES
3N = 3/8 PTF
6T = SAE 6
8T = SAE 8
CAVITY/SEAL Omit for Cartridge Only.
COIL CONNECTION
ar) FLOW PATH D = Double Lead
ACCESSORIES
S = Single Lead
H = Hirschmann
CROSSOVER C = Conduit
B = Double Spade
E = Single Stud
SEALS
N = Buna N
V = Viton
VOLTAGE
TECHNICAL
1.33.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 48
DSV2-080-4TC
Four-Way, Two-Position,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
A cartridge valve designed as a four-way, spool-type, directional
CONTROL
control valve, with two ports normally-closed and two ports normally-open.
MOTION
This valve is commonly used in a series circuit to allow flow to and from a
double-acting cylinder or motor.
CONTROL
OPERATION
FLOW
When energized, the cartridges spool shifts and allows flow from
to and from to .
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
SHUTTLE
SPECIFICATIONS
1.34.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 49
DSV2-080-4TC
Four-Way, Two-Position,
SOLENOID
Spool-Type Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 080 - 4 TC - * - * - * * * * - * *
PORTING
SOLENOID
DIRECTIONAL
2N = 1/4 PTF
VALVE
VALVES
3N = 3/8 PTF
4T = SAE 4
6T = SAE 6
CAVITY/SEAL Omit for Cartridge Only.
COIL CONNECTION
) FLOW PATH DE = Double Lead
ACCESSORIES
SE = Single Lead
HS = Hirschmann
TANDEM CENTER CS = Conduit
BE = Double Spade
EE = Single Stud
SEALS UE = Deutsch
N = Buna N
V = Viton
VOLTAGE
TECHNICAL
1.34.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 50
DSV2-080-4NO
Four-Way, Two-Position,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
control valve with all ports normally-open. This valve is commonly used
MOTION
OPERATION
CONTROL
FLOW
When energized, the spool shifts and all flow paths are blocked.
When de-energized, the cartridges spool allows flow from to
and from and .
RELIEF
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
Manual override option.
SHUTTLE
SPECIFICATIONS
VALVES
10192-74 03/11
1.36.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 51
DSV2-080-4NO
Four-Way, Two-Position,
SOLENOID
Spool-Type Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV2 - 080 - 4 NO - * - * - * * * * - * *
PORTING
SOLENOID
DIRECTIONAL
2N = 1/4 PTF
VALVE
VALVES
3N = 3/8 PTF
6T = SAE 6
8T = SAE 8
CAVITY/SEAL Omit for Cartridge Only.
COIL CONNECTION
FLOW PATH DE = Double Lead
ACCESSORIES
SE = Single Lead
HS = Hirschmann
NORMALLY OPEN CS = Conduit
BE = Double Spade
EE = Single Stud
SEALS UE = Deutsch
N = Buna N
V = Viton
VOLTAGE
TECHNICAL
1.36.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 52
DSV-080-34M
Four-Way, Three-Position, Motor Center
SOLENOID
SERIES 8
CHECK
DESCRIPTION
A cartridge valve designed as a three position, four-way solenoid valve.
CONTROL
MOTION
OPERATION
ports with the port blocked. When the upper solenoid (S1) is
energized, the valve allows flow between and ports and the
and ports. When the lower solenoid (S2) is energized, the valve
allows flow between the and ports and the and ports.
RELIEF
center position.
CONTROL
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
Industry common cavity.
SHUTTLE
Compact size.
SPECIFICATIONS
DIRECTIONAL
VALVES
10184-97 03/11
1.40.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 53
DSV-080-34M
Four-Way, Three-Position, Motor Center
SOLENOID
Spool-Type Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV - 080 - 34 M - * - * - * * * * - **
SOLENOID
DIRECTIONAL
PORTING
VALVE 2N = 1/4 PTF
VALVES
3N = 3/8 PTF
4T = SAE 4
CAVITY/SEAL 6T = SAE 6
Omit for Cartridge Only
DE = Double Lead
SE = Single Lead
MOTOR CENTER HS = Hirschmann
CS = Conduit
BE = Double Spade
SEALS EE = Single Stud
N = Buna N UE = Deutsch
V = Viton
TECHNICAL
1.40.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 54
DSV-100-34M
Four-Way, Three-Position, Motor Center
SOLENOID
SERIES 10
CHECK
DESCRIPTION
A cartridge valve designed as a three position, four-way solenoid valve.
CONTROL
MOTION
OPERATION
ports with the port blocked. When the upper solenoid (S1) is energized,
the valve allows flow between and ports and the and ports.
When the lower solenoid (S2) is energized, the valve allows flow between
the and ports and the and ports.
RELIEF
center position.
CONTROL
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
Industry common cavity.
SHUTTLE
Compact size.
SPECIFICATIONS
DIRECTIONAL
VALVES
20 (1.4)
alloy rated at 3000 PSI (207 Bar)
DATA
10 (0.7)
1 2 3 4 5 6
(3.8) (7.6) (11.4) (15.1) (18.9) (22.7)
10172-00 03/11
1.41.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 55
DSV-100-34M
Four-Way, Three-Position, Motor Center
SOLENOID
Spool-Type Solenoid Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV - 100 - 34 M - * - * - * * * - **
SOLENOID PORTING
DIRECTIONAL
VALVE 2N = 1/4 PTF
VALVES
3N = 3/8 PTF
6T = SAE 6
CAVITY/SEAL 8T = SAE 8
Omit for Cartridge Only
D = Double Lead
S = Single Lead
MOTOR CENTER H = Hirschmann
C = Conduit
B = Double Spade
SEALS E = Single Stud
N = Buna N
VOLTAGE
V = Viton
TECHNICAL
1.41.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 56
DSV-080-34T
Four-Way, Three-Position, Tandem Center
SOLENOID
SERIES 8
CHECK
DESCRIPTION
A cartridge valve designed as a three position, four-way solenoid valve.
CONTROL
MOTION
S1 S2
OPERATION
When de-energized, the valve allows flow between the and ports
CONTROL
FLOW
with ports and blocked. When the lower solenoid (S2) is energized,
the valve allows flow between the and ports and the and ports.
When the upper (S1) solenoid is energized, the valve allows flow
between the and ports and the and ports.
RELIEF
center position.
CONTROL
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
Industry common cavity.
SHUTTLE
Compact size.
SPECIFICATIONS
DIRECTIONAL
VALVES
NEUTRAL
150 ssu/32 cSt OIL @ 100F/38C
Coil Rating: Continuous from 85% to 110% of rated voltage.
225 (15.5)
Current Draw: 12 VDC is 1.3 amps.
200 (13.8)
Minimum Pull-In Voltage: 85% of rated voltage at 3000 PSI (207 Bar)
175 (12.1)
Recommended Filtration: ISO 17/15/13
150 (10.3)
125 (8.6)
Fluids: Mineral-based fluids. For other fluid compatibility, consult factory.
100 (6.9) Cavity/Cavity Tool: 080-4, see page 11.08.4
75 (5.2) In-Line Body Material: Anodized 6061T6 aluminum
TECHNICAL
25 (1.7)
0
0 0.5 1 1.5 2 2.5 3
(1.9) (3.8) (5.7) (7.6) (9.5) (11.4)
10172-65 03/11
1.42.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 57
DSV-080-34T
Four-Way, Three-Position, Tandem Center
SOLENOID
Spool-Type Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV - 080 - 34 T - * - * - * * * * - * *
SOLENOID PORTING
DIRECTIONAL
VALVE 2N = 1/4 PTF
VALVES
3N = 3/8 PTF
4T = SAE 4
CAVITY/SEAL 6T = SAE 6
Omit for Cartridge Only
DE = Double Lead
SE = Single Lead
TANDEM CENTER HS = Hirschmann
CS = Conduit
BE = Double Spade
SEALS EE = Single Stud
N = Buna N UE = Deutsch
V = Viton
TECHNICAL
1.42.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 58
DSV-100-34T
Four-Way, Three-Position, Tandem Center
SOLENOID
SERIES 10
CHECK
DESCRIPTION
A cartridge valve designed as a three position, four-way solenoid valve.
CONTROL
MOTION
S1 S2
OPERATION
When de-energized, the valve allows flow between the and ports
CONTROL
FLOW
with the and ports blocked. When the lower solenoid (S2) is
energized, the valve allows flow between and ports and the and
ports. When the upper solenoid (S1) is energized, the valve allows
flow between the and ports and the and ports.
RELIEF
center position.
CONTROL
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
Industry common cavity.
SHUTTLE
Compact size.
SPECIFICATIONS
DIRECTIONAL
VALVES
60 (4.1)
40 (2.8) alloy rated at 3000 PSI (207 Bar)
DATA
20 (1.4)
0
1.0 2.0 3.0 4.0 5.0
(3.8) (7.6) (11.4) (15.1) (18.9)
10172-01 03/11
1.43.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 59
DSV-100-34T
Four-Way, Three-Position, Tandem Center
SOLENOID
Spool-Type Solenoid Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV - 100 - 34 T - * - * - * * * - **
SOLENOID PORTING
DIRECTIONAL
VALVE 2N = 1/4 PTF
VALVES
3N = 3/8 PTF
6T = SAE 6
CAVITY/SEAL 8T = SAE 8
Omit for Cartridge Only
D = Double Lead
S = Single Lead
TANDEM CENTER H = Hirschmann
C = Conduit
B = Double Spade
SEALS E = Single Stud
N = Buna N
VOLTAGE
V = Viton
TECHNICAL
1.43.2
E1812-DSV-100-34TR spread:Deltrol2004Run8 3/6/11 9:13 PM Page 1
DSV-100-34TR
Four-Way, Three-Position, Regen
SOLENOID
SERIES 10
CHECK
DESCRIPTION
A cartridge valve designed as a three position, four-way solenoid valve
CONTROL
S1 S2
OPERATION
CONTROL
FLOW
When de-energized, the valve allows flow between the and ports
with ports and blocked. When the upper solenoid (S1) is energized,
the valve allows flow between the and ports and the and ports.
When the lower solenoid (S2) is energized, the valve allows flow between
RELIEF
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges and voltage interchangeable.
SEQUENCE
B
SHUTTLE
SPECIFICATIONS
T
Operating Pressure: 3000 PSI (207 Bar)
A Max. Flow: 1.5 GPM (5.75 l/min)
Internal Leakage: 5 in3/min (82 cc/min) at 3000 PSI (207 Bar)
DIRECTIONAL
5 (.34)
DATA
0
0 .25 .50 .75 1.0 1.25 1.5
(3.8) (7.6) (11.4) (15.2) (19.0) (23)
FLOW gpm (L/min.)
E1812 03/11
1.43.3
E1812-DSV-100-34TR spread:Deltrol2004Run8 3/6/11 9:13 PM Page 2
DSV-100-34TR
Four-Way, Three-Position, Regen
SOLENOID
Spool-Type Solenoid Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
.88 (22.4) HEX.
TORQUE
CONTROL
40 IN.-LBS.
MOTION
(4.5 Nm) MAX.
CONTROL
FLOW
4.48
(113.8)
.75 (19.0)
RELIEF
7.70
(195.58)
1.38
(34.93)
2.00
1.0 (25.4) HEX (50.8)
PRESSURE
2.88
CONTROL
B TORQUE
30 FT-LBS (73.0) 3.25
2.48 (82.55)
(63.03) T
(40.7 Nm) MAX.
SEQUENCE
P .25 (6.3) 2.00 (50.8) 1.25
(31.75)
2.50 (63.5)
( ) Parentheses = Millimeters
SHUTTLE
HOW TO ORDER
DSV - 100 - 34TR - * - * * * - **
SOLENOID VALVE PORTING
2N = 1/4
DIRECTIONAL
CAVITY/SEAL 3N = 3/8
VALVES
4T = SAE 4
FLOW PATH 6T = SAE 6
Omit for Cartridge Only
TANDEM CENTER
With Regen Function
COIL CONNECTION
SEALS
ACCESSORIES
D = Double Lead
N = Buna-N
S = Single Lead
V = Viton D = DC H = Hirschmann
A = AC C = Conduit
B = Double Spade
VOLTAGE
E = Single Stud
1 = 12 Volt 6 = 240 Volt
U = Deutsch
2 = 24 Volt 9 = 20 Volt
TECHNICAL
1.43.4
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 60
DSV-080-34C
Four-Way, Three-Position, Closed Center
SOLENOID
SERIES 8
CHECK
DESCRIPTION
A cartridge valve designed as a three position, four-way solenoid valve.
CONTROL
MOTION
OPERATION
When de-energized, the valve prevents flow at all ports. When the
CONTROL
FLOW
upper solenoid (S1) is energized, the valve allows flow between the
and ports and the and ports. When the lower solenoid (S2)
is energized, the valve allows flow between the and ports and
the and ports.
RELIEF
center position.
CONTROL
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
Industry common cavity.
SHUTTLE
Compact size.
SPECIFICATIONS
DIRECTIONAL
VALVES
10172-64(C) 03/11
1.44.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 61
DSV-080-34C
Four-Way, Three-Position, Closed Center
SOLENOID
Spool-Type Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV - 080 - 34 C - * - * - * * ** - **
SOLENOID PORTING
DIRECTIONAL
VALVE 2N = 1/4 PTF
VALVES
3N = 3/8 PTF
4T = SAE 4
CAVITY/SEAL 6T = SAE 6
Omit for Cartridge Only
DE = Double Lead
SE = Single Lead
CLOSED CENTER HS = Hirschmann
CS = Conduit
BE = Double Spade
SEALS EE = Single Stud
N = Buna N UE = Deutsch
V = Viton
TECHNICAL
M = Manual Override
DATA
VOLTAGE
(Omit for standard) 1 = 12 Volt 6 = 240 Volt
Omit coil for cartridge only with nut. D = DC 2 = 24 Volt 9 = 20 Volt
Other porting and coil options available consult factory. A = AC 5 = 120 Volt 10 = 10 Volt
1.44.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 62
DSV-100-34C
Four-Way, Three-Position, Closed Center
SOLENOID
SERIES 10
CHECK
DESCRIPTION
A cartridge valve designed as a three position, four-way solenoid valve.
CONTROL
MOTION
OPERATION
When de-energized, the valve prevents flow at all ports. When the upper
CONTROL
FLOW
solenoid (S1) is energized, the valve allows flow between and ports
and the and ports. When the lower solenoid (S2) is energized, the
valve allows flow between the and ports and the and ports.
RELIEF
Continuous-duty solenoid.
SEQUENCE
SPECIFICATIONS
DIRECTIONAL
10172-03 03/11
1.45.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 63
DSV-100-34C
Four-Way, Three-Position, Closed Center
SOLENOID
Spool-Type Solenoid Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV - 100 - 34 C - * - * - * * * - **
SOLENOID PORTING
DIRECTIONAL
VALVE 2N = 1/4 PTF
VALVES
3N = 3/8 PTF
6T = SAE 6
CAVITY/SEAL 8T = SAE 8
Omit for Cartridge Only
D = Double Lead
S = Single Lead
CLOSED CENTER H = Hirschmann
C = Conduit
B = Double Spade
SEALS E = Single Stud
N = Buna N
VOLTAGE
V = Viton
TECHNICAL
1.45.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 64
DSV-080-34O
Four-Way, Three-Position, Open Center
SOLENOID
SERIES 8
CHECK
DESCRIPTION
A cartridge valve designed as a three position, four-way solenoid valve.
CONTROL
MOTION
S1 S2
OPERATION
When de-energized, the valve allows flow at all ports. When the
CONTROL
FLOW
upper solenoid (S1) is energized, the valve allows flow between the
and ports and the and ports. When the lower solenoid (S2)
is energized, the valve allows flow between the and ports and
the and ports.
RELIEF
center position.
CONTROL
Continuous-duty solenoid.
Hardened precision spool and sleeve for long life.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional coil voltages and terminations.
Industry common cavity.
SHUTTLE
Compact size.
SPECIFICATIONS
DIRECTIONAL
VALVES
10187-35(D) 03/11
1.46.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 65
DSV-080-34O
Four-Way, Three-Position, Open Center
SOLENOID
Spool-Type Solenoid Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV - 080 - 34 O - * - * - * * * * - * *
SOLENOID PORTING
DIRECTIONAL
VALVE 2N = 1/4 PTF
VALVES
3N = 3/8 PTF
4T = SAE 4
CAVITY/SEAL 6T = SAE 6
Omit for Cartridge Only
DE = Double Lead
SE = Single Lead
OPEN CENTER HS = Hirschmann
CS = Conduit
BE = Double Spade
SEALS EE = Single Stud
N = Buna N UE = Deutsch
V = Viton
TECHNICAL
1.46.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 66
DSV-100-34O
Four-Way, Three-Position, Open Center
SOLENOID
SERIES 10
CHECK
DESCRIPTION
A cartridge valve designed as a three position, four-way solenoid valve.
CONTROL
MOTION
S1 S2
OPERATION
When de-energized, the valve allows flow at all ports. When the upper
CONTROL
FLOW
solenoid (S1) is energized, the valve allows flow between the and
ports and the and ports. When the lower solenoid (S2) is energized,
the valve allows flow between the and ports and the and ports.
RELIEF
P SPECIFICATIONS
DIRECTIONAL
10172-02 03/11
1.47.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:32 PM Page 67
DSV-100-34O
Four-Way, Three-Position, Open Center
SOLENOID
Spool-Type Solenoid Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSV - 100 - 34 O - * - * - * * * - **
SOLENOID PORTING
DIRECTIONAL
VALVE 2N = 1/4 PTF
VALVES
3N = 3/8 PTF
6T = SAE 6
CAVITY/SEAL 8T = SAE 8
Omit for Cartridge Only
D = Double Lead
S = Single Lead
OPEN CENTER H = Hirschmann
C = Conduit
B = Double Spade
SEALS E = Single Stud
N = Buna N
VOLTAGE
V = Viton
TECHNICAL
1.47.2
E1615-DPV-100-2NC spread:Deltrol2004Run8 3/6/11 9:10 PM Page 1
DPV-100-2NC
Normally-Closed,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
A cartridge valve designed as a normally closed, spool-type, proportional
CONTROL
As electrical current is applied to the coil, the spool will gradually shift
from closed to open as current increases to 2 amps maximum. Flow will
pass from port to port up to 300 psi differential.
Port is plugged.
RELIEF
The valve can also function as a differential control for load sense
applications.
The valve functions with industry-common controllers which provide
PRESSURE
300 (20.7)
250 (17.2)
(3) Industry common cavity.
DIRECTIONAL
200 (13.8)
(7)
Compact size.
VALVES
150 (10.3)
(14)
100 (6.9)
50 (3.4) SPECIFICATIONS
0
0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 Coil Specifications:
(7.6) (15.1) (22.7) (30.3) (37.9) (45.4) (52.9)
FLOW gpm (L/min.) 12 Volt System 24 Volt System
Resistance 4.0 ohms @ 20C Resistance 16.0 ohms @ 20C
ACCESSORIES
3.5 (13.2)
3.0 (11.4)
Flow: See PERFORMANCE DROP VS. FLOW graph.
2.5 (9.5) Internal Leakage: (per land) 10 in3/min. (164 cc/min) at
2.0 (7.6) 3000 PSI (207 Bar)
TECHNICAL
0.5 (1.9)
0
Recommended Filtration: ISO 16/12
0 0.5 1.0 1.5 2.0 2.5
Fluids: Mineral-based fluids.
CURRENT amp
12 VDC COIL, 100 Hz DITHER, PWM CONTROLLER Cavity/Cavity Tool: 100-3, see page 11.10.3
E1615 02/11
1.80.1
E1615-DPV-100-2NC spread:Deltrol2004Run8 3/6/11 9:10 PM Page 2
DPV-100-2NC
Normally-Closed,
SOLENOID
Proportional, Flow Control Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.75 (19.0) HEX.
TORQUE 10 IN. LBS.
(1.1 Nm) MAX.
3.28
XX AMPS
XXX VDC
(83.3)
CONTROL
FLOW
XX AMPS
XXX VDC
RELIEF
.75
(19.0)
1.37
1.00 (25.4) HEX. (34.9) 2
TORQUE 30 FT./LBS.
(40.7 Nm) MAX. 2.12 (54.0) 2.62
(66.9)
PRESSURE
CONTROL
.28 (7.1) TYP.
Plugged
1.25 (31.7)
.62
(15.9)
1.25
SEQUENCE
.250 (6.3) 2.00 (50.8) (31.7)
2.50 (63.5)
( ) Parentheses = Millimeters
SHUTTLE
HOW TO ORDER
DPV - 100 - 2 NC * - * - * * * - **
DIRECTIONAL
PROPORTIONAL BODY PORTING
VALVES
FLOW CONTROL VALVE 6T = SAE 6
8T = SAE 8
CAVITY/SEAL Omit for cartridge only.
FLOW PATH
NORMALLY CLOSED
ACCESSORIES
COIL CONNECTION
H = Hirschmann
FLOW RANGE GPM Max B = Double Spade
3 = 3 GPM (11.4 L/min)
7 = 7 GPM (26.5 L/min) SEALS
14 = 14 GPM (53.0 L/min) N = Buna N
V = Viton
TECHNICAL
D = DC
VOLTAGE
DATA
A = AC
1 = 12 Volt
2 = 24 Volt
1.80.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 68
ZCO-42
Direct-Acting, Ball-Type
SOLENOID
Check Valve
ZERO PROFILE
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
Low leak.
Compact size.
SPECIFICATIONS
SEQUENCE
10203-98 02/11
2.01.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 69
ZCO-42
Direct-Acting, Ball-Type
SOLENOID
Check Valve
ZERO PROFILE
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
ZCO - 42 - U - **
DIRECTIONAL
PORTING
CHECK VALVE 4T = SAE 4
VALVES
6T = SAE 6
CAVITY Omit for Cartridge Only.
SEALS
ACCESSORIES
U = Urethane
TECHNICAL
DATA
2.01.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 70
ZCP6
Direct-Acting, Poppet-Type
SOLENOID
Check Valve
ZERO PROFILE
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
Low leak.
Compact size.
SPECIFICATIONS
SEQUENCE
25 (1.72)
PRESSURE DROP psi (bar)
20 (1.38)
15 (1.03)
10 (0.7)
TECHNICAL
5 (0.3)
DATA
0
0 1.0 2.0 3.0 4.0 5.0
(3.8) (7.6) (11.4) (15.2) (19.0)
FLOW gpm (L/min.)
10208-12(B) 02/11
2.03.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 71
ZCP6
Direct-Acting, Poppet-Type
SOLENOID
Check Valve
ZERO PROFILE
CHECK
INSTALLATION DIMENSIONS
.09
(2.3) 9/16-18UNF-2B THREAD
8 PLACES
CONTROL
MOTION
.33
CONTROL
(8.4)
FLOW
118 125
RELIEF
9/16-18 THREAD .118
.07 (1.8) MAX. TORQUE 5 IN.-LBS. (3.00) MAX.
PRESSURE
(0.6 Nm) MAX.
CONTROL
.35 .276
(8.9) (7.01) MAX.
ZCP6 CAVITY
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
ZCP6 - * - **
CHECK VALVE/CAVITY
DIRECTIONAL
VALVES
SEALS CRACK PRESSURE
N = Buna 5 = 5 PSI (0.3 Bar)
V = Viton 10 = 10 PSI (0.7 Bar)
ACCESSORIES
TECHNICAL
DATA
2.03.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 72
ZC-62
Direct-Acting, Ball-Type
SOLENOID
Check Valve
ZERO PROFILE
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
Slip in style.
PRESSURE
CONTROL
SPECIFICATIONS
Operating Pressure: 3000 PSI (207 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
Nominal Flow 4 GPM (15.1 L/min).
SHUTTLE
240 (16.56)
PRESSURE DROP psi (bar)
200 (13.80)
160 (11.04)
120 (8.25)
80 (5.52)
TECHNICAL
40 (2.76)
DATA
0
0 1.0 2.0 3.0 4.0 5.0
(3.8) (7.6) (11.4) (15.2) (19.0)
FLOW gpm (L/min.)
10176-08 02/11
2.07.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 73
ZC-62
Direct-Acting, Ball-Type
SOLENOID
Check Valve
ZERO PROFILE
CHECK
INSTALLATION DIMENSIONS
#6 SAE PLUG
CONTROL
MOTION
.48
(12.2)
CONTROL
.75
FLOW
.84 (19.0)
(21.3)
2.11
2.00 (53.6)
(50.8)
RELIEF
.28 TYP.
(7.1)
.50
(12.7)
PRESSURE
CONTROL
1.00
(25.4) .50
1.50 (12.7)
.25 (38.1)
(6.4) 1.00
2.00 (25.4)
(50.8)
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
ZC - 62 - U - ** - **
DIRECTIONAL
PORTING
CHECK VALVE 4T = SAE 4
VALVES
6T = SAE 6
CAVITY Omit for Cartridge Only.
SEALS
ACCESSORIES
U = Urethane
CRACK PRESSURE
5 = 5 PSI (0.3 Bar)
30 = 30 PSI (2.1 Bar)
(Other Options Available Consult Factory)
TECHNICAL
DATA
2.07.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 74
ZCO-62
Zero Leak, Direct-Acting,
SOLENOID
ZERO PROFILE
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
Slip in style.
Zero leak.
Compact size.
SEQUENCE
SPECIFICATIONS
60 (4.1)
PRESSURE DROP psi (bar)
50 (3.5)
40 (2.8)
30 (2.1)
20 (1.4)
TECHNICAL
10 (0.7)
DATA
0
0 0.5 1.0 1.5 2.0 2.5
(1.9) (3.8) (5.7) (7.6) (9.5)
10198-73(F) 02/11
2.08.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 75
ZCO-62
Zero Leak, Direct-Acting,
SOLENOID
Poppet-Type Check Valve
ZERO PROFILE
CHECK
INSTALLATION DIMENSIONS
#6 SAE PLUG
CONTROL
MOTION
.48
(12.2)
.75
.84 (19.0)
CONTROL
(21.3)
FLOW
2.00 2.11
(50.8) (53.6)
RELIEF
.28 TYP.
.50 (7.1)
(12.7)
PRESSURE
CONTROL
1.50
(38.1) .50
1.00 (12.7)
.25
(6.4) (25.4) 1.00
2.00 (25.4)
(50.8)
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
ZCO - 62 - U - ** - **
DIRECTIONAL
PORTING
CHECK VALVE 4T = SAE 4
VALVES
6T = SAE 6
Omit for Cartridge Only.
CAVITY
SEALS
ACCESSORIES
U = Urethane
CRACK PRESSURE
1 = 1 - 2 PSI (0.67 - 0.14 Bar)
TECHNICAL
DATA
2.08.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 76
DCV-080-B
Direct-Acting, Ball-Type
SOLENOID
Check Valve
SERIES 8
CHECK
DESCRIPTION
A cartridge valve designed to allow free flow in one direction, while
CONTROL
OPERATION
CONTROL
FLOW
SPECIFICATIONS
PRESSURE DROP VS. FLOW Recommended Filtration: Critical Application ISO 17/15/13
Non-Critical Application ISO 20/18/14
Fluids: Mineral-based fluids.
120 (8.3) For other fluid compatibility, consult factory.
Cavity/Cavity Tool: 080-2, see page 11.08.2
100 (6.9) In-Line Body Material: Anodized 6061T6 aluminum
PRESSURE DROP psi (bar)
ACCESSORIES
60 (4.1)
40 (2.8)
TECHNICAL
20 (1.4)
DATA
0
0 1.0 2.0 3.0 4.0 5.0
(3.8) (7.6) (11.4) (15.1) (18.9)
FLOW gpm (L/min.)
10129-82 02/11
2.09.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 77
DCV-080-B
Direct-Acting, Ball-Type
SOLENOID
Check Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DCV - 080 - B - * - ** - **
CHECK VALVE
DIRECTIONAL
VALVES
PORTING
CAVITY/SEAL
2N = 1/4 PTF
3N = 3/8 PTF
4T = SAE 4
6T = SAE 6
Omit for Cartridge Only.
ACCESSORIES
2.09.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 78
DCV-100-B
Direct-Acting, Ball-Type
SOLENOID
Check Valve
SERIES 10
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
Low leak.
Industry common cavity.
Compact size.
SEQUENCE
SPECIFICATIONS
10179-35 02/11
2.10.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 79
DCV-100-B
Direct-Acting, Ball-Type
SOLENOID
Check Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.38
(9.7) 1.00 (25.4) HEX.
TORQUE 30 FT.-LBS.
(40.7 Nm) MAX.
CONTROL
FLOW
1.25 .75
(31.8) (19.0)
1.50
(38.1)
2.38
2.00
(60.5)
(50.8)
RELIEF
.28 TYP.
(7.1)
PRESSURE
CONTROL
1.25 .63
(31.8) (16.0)
.13 1.63 1.25
(3.3) (41.4) (31.8)
2.00
(50.8)
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DCV - 100 - B - * - *** - **
CHECK VALVE
DIRECTIONAL
VALVES
PORTING
CAVITY/SEAL 2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
BALL 8T = SAE 8
Omit for Cartridge Only.
ACCESSORIES
CRACK PRESSURE
5 = 5 PSI ( 0.3 Bar)
TECHNICAL
2.10.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 80
DCV-080-PB
Direct-Acting, Ball-Type
SOLENOID
Check Valve
SERIES 8
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
SPECIFICATIONS
10 (.7)
5 (.3)
TECHNICAL
DATA
0
0 1.0 2.0 3.0 4.0 5.0
(3.8) (7.6) (11.4) (15.1) (18.9)
10140-74 02/11
2.11.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 81
DCV-080-PB
Direct-Acting, Ball-Type
SOLENOID
Check Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DCV - 080 - PB - * - *** - **
CHECK VALVE
DIRECTIONAL
VALVES
PORTING
CAVITY/SEAL 2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
BALL 8T = SAE 8
Omit for Cartridge Only.
ACCESSORIES
(Other porting
SEAL options available
consult factory.)
N = Buna N
V = Viton
CRACK PRESSURE
5 = 5 PSI (0.3 Bar)
TECHNICAL
2.11.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 82
DCV-100-PB
Direct-Acting, Ball-Type
SOLENOID
Check Valve
SERIES 10
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
SPECIFICATIONS
10177-92 02/11
2.12.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 83
DCV-100-PB
Direct-Acting, Ball-Type
SOLENOID
Check Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.38
(9.7) 1.00 (25.4) HEX.
TORQUE 30 FT.- LBS.
(40.7 Nm) MAX.
CONTROL
FLOW
1.25 .75
(31.8) (19.0)
1.50
(38.1)
2.38
2.00
(60.5)
(50.8)
RELIEF
.28 TYP.
(7.1)
1.25
PRESSURE
.63
CONTROL
(31.8)
(16.0)
.13 1.63 1.25
(3.3) (41.4) (31.8)
2.00
(50.8)
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DCV - 100 - PB - * - *** - **
CHECK VALVE
DIRECTIONAL
VALVES
PORTING
CAVITY/SEAL 2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
BALL 8T = SAE 8
Omit for Cartridge Only.
ACCESSORIES
CRACK PRESSURE
5 = 5 PSI ( 0.3 Bar)
TECHNICAL
2.12.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 84
DCV-100-P
Direct-Acting, Poppet-Type
SOLENOID
SERIES 10
CHECK
DESCRIPTION
A cartridge valve designed to allow free flow in one direction, while
CONTROL
OPERATION
CONTROL
FLOW
SPECIFICATIONS
SEQUENCE
65 PSI
alloy rated at 3000 PSI (207 Bar).
100 (6.9)
75 (5.2)
30 PSI
50 (3.4) 5 PSI
25 (1.7)
TECHNICAL
DATA
0
0 2.0 4.0 6.0 8.0 10.0
(7.6) (15.1) (22.7) (30.3) (37.9)
FLOW gpm (L/min.)
10129-89 02/11
2.14.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 85
DCV-100-P
Direct-Acting, Poppet-Type
SOLENOID
Cartridge Check Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DCV - 100 - P - * - *** - **
CHECK VALVE
DIRECTIONAL
VALVES
PORTING
CAVITY/SEAL 2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
POPPET 8T = SAE 8
Omit for Cartridge Only.
ACCESSORIES
CRACK PRESSURE
5 = 5 PSI ( 0.3 Bar)
15 = 15 PSI ( 1.0 Bar)
TECHNICAL
2.14.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 86
ZPC-63
Pilot To Open, Ball-Type
SOLENOID
Check Valve
ZERO PROFILE
CHECK
DESCRIPTION
A cartridge valve designed to allow free flow in one direction, while
CONTROL
OPERATION
FLOW
Slip in style.
Torlon ball for positive shut-off.
SEQUENCE
Low leak.
Compact size.
Sealed pilot piston.
SHUTTLE
SPECIFICATIONS
Operating Pressure: 1500 PSI (103 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
Nominal Flow 3 GPM (11.4 L/min).
DIRECTIONAL
10195-60 02/11
3.01.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 87
ZPC-63
Pilot To Open, Ball-Type
SOLENOID
Check Valve
ZERO PROFILE
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
ZPC - 63 - U - ** - **
DIRECTIONAL
PORTING
4T = SAE 4
VALVES
PILOT-OPERATED
CHECK VALVE 6T = SAE 6
CAVITY Omit for Cartridge Only.
SEALS
ACCESSORIES
U = Urethane
CRACK PRESSURE
30 = 30 PSI (2.1 Bar)
TECHNICAL
DATA
3.01.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 88
ZPC2-63
Pilot To Open, Ball-Type
SOLENOID
Check Valve
ZERO PROFILE
CHECK
DESCRIPTION
A cartridge valve designed to allow free flow in one direction, while
CONTROL
OPERATION
FLOW
Slip in style
Compact size.
SEQUENCE
SPECIFICATIONS
10216-02(C) 02/11
3.02.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 89
ZPC2-63
Pilot To Open, Ball-Type
SOLENOID
Check Valve
ZERO PROFILE
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
ZPC2 - 63 - U - ** - **
DIRECTIONAL
PORTING
4T = SAE 4
VALVES
PILOT-OPERATED
CHECK VALVE 6T = SAE 6
CAVITY Omit for Cartridge Only.
SEALS
ACCESSORIES
U = Urethane
CRACK PRESSURE
30 = 30 PSI (2.1 Bar)
TECHNICAL
DATA
3.02.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 90
DPC-080-P
Pilot To Open, Poppet-Type
SOLENOID
Check Valve
SERIES 8
CHECK
DESCRIPTION
A cartridge valve designed to allow free flow in one direction while
CONTROL
OPERATION
FLOW
Compact size.
SPECIFICATIONS
SHUTTLE
40 (2.8)
TECHNICAL
DATA
0
0 1.0 2.0 3.0 4.0 5.0
(3.8) (7.6) (11.4) (15.1) (18.9)
FLOW gpm (L/min.)
10225-35 02/11
3.03.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 91
DPC-080-P
Pilot To Open, Poppet-Type
SOLENOID
Check Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.25
(6.4)
.88 (22.4) HEX.
TORQUE 20 FT.-LBS.
(27.1 Nm) MAX.
CONTROL
2.85
FLOW
(72.4)
1.63
RELIEF
(41.4)
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DPC - 080 - P - * - *** - **
PILOT-OPERATED
DIRECTIONAL
CHECK VALVE
VALVES
PORTING
CAVITY/SEAL 2N = 1/4 PTF
3N = 3/8 PTF
4T = SAE 4
P = Poppet 6T = SAE 6
ACCESSORIES
CRACK PRESSURE
TECHNICAL
3.03.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 92
DPC-100-P
Pilot To Open, Poppet-Type
SOLENOID
Check Valve
SERIES 10
CHECK
DESCRIPTION
A cartridge valve designed to allow free flow in one direction while
CONTROL
OPERATION
FLOW
Compact size.
SPECIFICATIONS
SHUTTLE
240 (16.6)
PRESSURE DROP psi (bar)
40 (2.8)
TECHNICAL
DATA
0
0 1.0 2.0 3.0 4.0 5.0 6.0
(3.8) (7.6) (11.4) (15.1) (18.9) (22.7)
FLOW gpm (L/min.)
10119-70 02/11
3.04.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 93
DPC-100-P
Pilot To Open, Poppet-Type
SOLENOID
Check Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.38
(9.7) 1.00 (25.4) HEX.
TORQUE 30 FT. - LBS.
(40.7 Nm) MAX.
.75
(19.1) 1.38
CONTROL
(35.1)
FLOW
1.82
(46.2) 2.13
(54.1) 2.63
(66.8)
3.01
(76.5)
RELIEF
.28 TYP.
(7.1)
1.25 .63
(31.8) (16.0)
PRESSURE
.25 2.00 1.25
CONTROL
(6.4) (50.8) (31.8)
2.50
(63.5)
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DPC - 100 - P - * - *** - **
PILOT-OPERATED
DIRECTIONAL
CHECK VALVE
VALVES
PORTING
CAVITY/SEAL 2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
P = Poppet 8T = SAE 8
ACCESSORIES
CRACK PRESSURE
TECHNICAL
3.04.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 94
DDPC-080-P
Dual Pilot To Open, Poppet-Type
SOLENOID
Check Valve
SERIES 8
CHECK
DESCRIPTION
OPERATION
FLOW
SPECIFICATIONS
Operating Pressure: 3000 PSI (207 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
Nominal flow 2 gpm (7.6 L/min.)
DIRECTIONAL
10181-36(E) 02/11
3.07.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 95
DDPC-080-P
Dual Pilot To Open, Poppet-Type
SOLENOID
Check Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.53
(13.5)
.61
(15.5) 1.17
CONTROL
(29.7)
FLOW
1.73
2.69 (43.9)
(68.3) 3.75
21.6 2.88 (95.2)
(54.8) (73.2) 3.25
(82.6)
RELIEF
PRESSURE
CONTROL
.28 TYP.
(7.1) 1.25 .56
.25 (31.8) (14.2)
(6.4) 2.00 1.13
(50.8) (28.7)
2.50
(63.5)
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DDPC - 080 - P - * - *** - **
DUAL PILOT-OPERATED
DIRECTIONAL
CHECK VALVE
VALVES
PORTING
CAVITY/SEAL 2N = 1/4 PTF
3N = 3/8 PTF
4T = SAE 4
P = Poppet 6T = SAE 6
ACCESSORIES
CRACK PRESSURE
TECHNICAL
3.07.2
E1756-DDPC-100-P spread:Deltrol2004Run8 3/6/11 9:07 PM Page 1
DDPC-100-P
Dual Pilot To Open, Poppet-Type
SOLENOID
Check Valve
SERIES 10
CHECK
DESCRIPTION
OPERATION
FLOW
area is to .
CONTROL
SPECIFICATIONS
Operating Pressure: 4000 PSI (276 Bar)
Flow: Nominal Flow 6 gpm (22.8 l/min)
Internal Leakage: 5 drops/min (0.25 cc/min) aty 3000 PSI (207 Bar)
DIRECTIONAL
300 (20.4)
200 (13.6)
TECHNICAL
100 (6.8)
DATA
0
0 1.0 2.0 3.0 4.0 5.0 6.0
(3.8) (7.6) (11.4) (15.2) (19.0) (22.8)
FLOW gpm (L/min.)
E1756 01/11
3.07.3
E1756-DDPC-100-P spread:Deltrol2004Run8 3/6/11 9:07 PM Page 2
DDPC-100-P
Dual Pilot To Open, Poppet-Type
SOLENOID
Check Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS1
1.00 (25.4) HEX.
TORQUE 30 FT-LBS.
CONTROL
(40.7 Nm) MAX.
MOTION
.75
CONTROL
(19.1)
FLOW
1.38
(35.1)
2.00
(1
(50.8)
2.00 3.76
(50.8) (95.4)
2.99 3.25
RELIEF
(75.9) 2.50 2.88 (82.5)
(63.5) (73.0)
2.88
(73.0)
PRESSURE
CONTROL
.28 TYP.
(7.1)
1.25
(31.8)
.63
(16.0)
2.00 1.25
.28 TYP (50.8) (31.8)
.25
(7.1) 2.50
(6.3) (63.5)
.25
(6.3)
SEQUENCE
( ) Parentheses = Millimeters
SHUTTLE
HOW TO ORDER
DDPC - 100 - P - * - ** - **
DIRECTIONAL
PORTING
VALVES
2N = 1/4 PTF
3N = 3/8 PTF
DUAL PILOT-OPERATED
4T = SAE 4
CHECK VALVE
6T = SAE 6
Omit for Cartridge Only
CAVITY/SEAL ACCESSORIES
POPPET
3.07.4
E1466-ZPTC-63-U-XXX spread:Deltrol2004Run8 3/6/11 9:19 PM Page 1
ZPTC-63
Pilot to Close
SOLENOID
Check Valve
ZERO PROFIILE
CHECK
DESCRIPTION
A cartridge valve designed to allow free flow in one direction, while
CONTROL
OPERATION
FLOW
the required pilot pressure is achieved at , the ball unseats and allows
flow between and . The pilot piston area to poppet seat area ratio is
3:1.
PRESSURE
CONTROL
Slip-in style.
Compact size.
SEQUENCE
SPECIFICATIONS
Operating Pressure: 4000 PSI (276 Bar)
SHUTTLE
160 (11.0)
120 (8.3)
80 (5.5)
TECHNICAL
40 (2.8)
DATA
0
0 1 2 3 4 5
(3.8) (7.6) (11.4) (15.1) (18.9)
FLOW gpm (L/min.)
E1466 02/11
3.08.1
E1466-ZPTC-63-U-XXX spread:Deltrol2004Run8 3/6/11 9:19 PM Page 2
ZPTC-63
Pilot to Close
SOLENOID
Check Valve
ZERO PROFILE
CHECK
INSTALLATION DIMENSIONS
#6 SAE PLUG
CONTROL
MOTION
CONTROL
.48
FLOW
(12.2) 2.75
(69.8)
2.86
2.15 (72.6)
(54.7)
RELIEF
1.47
1.64 (37.2)
(41.7)
.28 (7.1)
TYP
PRESSURE
CONTROL
.50
(12.7)
.50 (12.7)
1.50 (38.1)
1.00 (25.4)
1.00 (25.4)
2.00 (50.8)
SEQUENCE
( ) Parentheses = Millimeters
SHUTTLE
HOW TO ORDER
ZPTC - 63 - U - ** - **
DIRECTIONAL
PILOT TO CLOSE PORTING
VALVES
CHECK VALVE 4T = SAE 4
6T = SAE 6
Omit for cartridge only.
CAVITY
ACCESSORIES
CRACK PRESSURE
30 = 30 PSI (2.1 Bar)
SEALS
V = Viton
U = Urethane
TECHNICAL
DATA
3.08.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 96
DPTC-100-P (Formerly
DPC2-100-P)
Check Valve
SERIES 10
CHECK
DESCRIPTION
A cartridge valve designed to allow free flow in one direction while
CONTROL
OPERATION
FLOW
Compact size.
SPECIFICATIONS
SHUTTLE
Pilot Ratio: 3 to 1 .
Temperature: -30F to +250F (-35C to +120C)
PRESSURE DROP VS. FLOW Recommended Filtration: Critical Application ISO 17/15/13
Non-Critical Application ISO 20/18/14
TO (FREE FLOW) Fluids: Mineral-based fluids.
150 ssu/32 cSt OIL @ 100F/38C
For other fluid compatibility, consult factory.
ACCESSORIES
240 (16.6)
100 PSI
Cavity/Cavity Tool: 100-3, see page 11.10.3
PRESSURE DROP psi (bar)
80 (5.5)
TECHNICAL
40 (2.8)
DATA
0
0 2.0 4.0 6.0 8.0 10.0 12.0
(7.6) (15.1) (22.7) (30.3) (37.9) (45.4)
10146-64 02/11
3.09.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 97
DPTC-100-P (Formerly
DPC2-100-P)
SOLENOID
Check Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.38 1.00 (25.4) HEX.
(9.7) TORQUE 30 FT.-LBS.
(40.7 Nm) MAX. .75
(19.1)
1.38
CONTROL
(35.1)
FLOW
2.13
(54.1)
2.63
(66.8)
1.83
(46.5) 3.01
(76.5)
RELIEF
.28 TYP.
(7.1)
PRESSURE
CONTROL
1.25 .63
(31.8) (16.0)
.25 1.25
2.00 (31.8)
(6.4) (50.8)
2.50
(63.5)
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DPTC - 100 - P - * - *** - **
PILOT-OPERATED
DIRECTIONAL
CHECK VALVE
VALVES
PORTING
CAVITY/SEAL 2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
P = Poppet 8T = SAE 8
ACCESSORIES
CRACK PRESSURE
TECHNICAL
3.09.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 98
DPCV-100-P
Vented, Pilot To Open, Poppet-Type
SOLENOID
Check Valve
SERIES 10
CHECK
DESCRIPTION
A cartridge valve designed to allow free flow in one direction while
CONTROL
by reaching the required pilot pressure. This valve is commonly used as
a load-holding or blocking valve.
CONTROL
OPERATION
FLOW
SPECIFICATIONS
Operating Pressure: 3000 PSI (207 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
Internal Leakage: 5 drops/min. max. at 3000 PSI (207 Bar)
DIRECTIONAL
Pilot Ratio: 3 to 1
PRESSURE DROP VS. FLOW Temperature: -30F to +250F (-35C to +120C)
Recommended Filtration: Critical Application ISO 17/15/13
TO (FREE FLOW) Non-Critical Application ISO 20/18/14
TO (PILOTED OPEN)
Fluids: Mineral-based fluids.
150 ssu/32 cSt OIL @ 100F/38C
For other fluid compatibility, consult factory.
ACCESSORIES
10153-96 02/11
3.11.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 99
DPCV-100-P
Vented, Pilot To Open, Poppet-Type
SOLENOID
Check Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.38 1.00 (25.4) HEX.
(9.7) TORQUE 30 FT.-LBS.
(40.7 Nm) MAX.
CONTROL
FLOW
2.72
RELIEF
(69.1)
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DPCV - 100 - P - * - 15
VENTED PILOT-OPERATED
DIRECTIONAL
CHECK VALVE
VALVES
CAVITY/SEAL
P = Poppet
ACCESSORIES
SEALS
N = Buna N
V = Viton
CRACK PRESSURE
TECHNICAL
3.11.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 100
DNV-080
Adjustable,
SOLENOID
Needle Valve
SERIES 8
CHECK
DESCRIPTION
positive shut-off.
MOTION
OPERATION
CONTROL
FLOW
The DNV-080 varies flow restriction by adjusting needle in or out and will
shut off when fully closed. This valve will meter flow in either direction.
RELIEF
SPECIFICATIONS
Operating Pressure: 3000 PSI (207 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
Nominal flow 11 GPM (41.6 L/min).
SHUTTLE
100 (6.9)
PRESSURE DROP psi (bar)
80 (5.5)
60 (4.1)
40 (2.8)
20 (1.4)
TECHNICAL
DATA
0
0 2 4 6 8 10 12
(7.6) (15.1) (22.7) (30.3) (38.0) (45.4)
FLOW gpm (L/min.)
10199-92 03/11
4.01.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 101
DNV-080
Adjustable,
SOLENOID
Needle Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
1.00 (25.4) DIA.KNOB
.88 (22.4) HEX.
TORQUE 30 FT.-LBS
(40.7 Nm) MAX.
CONTROL
1.34
FLOW
OPEN
1.11 3.34
(84.9) .75
CLOSED (19.2)
MAX.
1.50
RELIEF
(38.1)
2.00
(50.8)
1.06
.28 TYP.
PRESSURE
(7.1)
CONTROL
.13
1.25 .63
(31.8) (15.88)
(3.3)
1.63
(41.4) 1.25
SEQUENCE
(31.75)
2.00
(50.8)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DNV - 080 - * - K - **
DIRECTIONAL
VALVES
NEEDLE VALVE
PORTING
CAVITY/SEAL 4T = SAE 4
6T = SAE 6
Omit for Cartridge Only.
SEALS
ACCESSORIES
N = Buna N
V = Viton
K = Knob
TECHNICAL
DATA
4.01.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 102
DNV-100
Adjustable,
SOLENOID
Needle Valve
SERIES 10
CHECK
DESCRIPTION
A cartridge valve designed to provide a variable flow restriction with
CONTROL
positive shut-off.
MOTION
OPERATION
CONTROL
FLOW
The DNV-100 varies flow restriction by adjusting needle in or out and will
shut off when fully closed. This valve will meter flow in either direction.
RELIEF
Compact size.
SPECIFICATIONS
SHUTTLE
1.1
Fluids: Mineral-based fluids.
VALVES
1.0
.90 For other fluid compatibility, consult factory.
Cv FACTOR
.20
.10
0
0 1 2 3 4
NO. TURNS OPEN
Cv P1 P2
TECHNICAL
FLOW IN GPM =
Gf
DATA
10139-33 02/11
4.02.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 103
DNV-100
Adjustable,
SOLENOID
Needle Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
1.50 (38.1) DIA. KNOB
CONTROL
MAX. (40.7 Nm ) MAX.
FLOW
3.42
(86.9) .75
MAX. (19.1)
1.50
2.00
RELIEF
1.25 (38.1)
(31.8) (50.8)
PRESSURE
CONTROL
.28 TYP.
(7.1)
1.25 .63
(31.8) (16.0)
1.25
.13 1.63 (31.8)
SEQUENCE
(3.3) (41.4)
2.00
( ) Parentheses = Millimeters (50.8)
HOW TO ORDER
SHUTTLE
DNV - 100 - * - K - **
DIRECTIONAL
VALVES
NEEDLE VALVE
PORTING
CAVITY/SEAL
2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
ACCESSORIES
SEALS 8T = SAE 8
N = Buna N Omit for Cartridge Only.
V = Viton (Other porting options available
consult factory.)
K = Knob
TECHNICAL
DATA
4.02.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 104
NC-**-S
Adjustable,
SOLENOID
Needle Valve
SERIES NC
CHECK
DESCRIPTION
flow restriction with positive shut-off. Valve sizes range from 1/8" to 3/4".
MOTION
OPERATION
CONTROL
FLOW
Aluminum knob.
PRESSURE
CONTROL
SPECIFICATIONS
FLOW CHARACTERISTICS
ACCESSORIES
FLOW CV
MODEL MAX. RECOMMENDED FLOW FACTOR
GPM (L/min.) (FULL OPEN)
02/11
4.04.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 105
NC-**-S
Adjustable,
SOLENOID
Needle Valve
SERIES NC
CHECK
INSTALLATION DIMENSIONS
C
MALE THREAD SUPPLIED
CONTROL
MOTION
WITH PRE-APPLIED
THREAD LOCKER FOR
POSITIVE SEAL.
CONTROL
A
FLOW
E
D
RELIEF
PRESSURE
CONTROL
A B C D E
MODEL (WIDTH ACROSS (WIDTH ACROSS (DIA.) (CLOSED) (FULL OPEN)
HEX. FLATS) HEX. FLATS)
NC-10-S .38 (9.7) .38 (9.7) .78 (19.8) .75 (19.1) .88 (22.4)
NC-20-S .44 (11.2) .50 (12.7) .78 (19.8) .86 (21.8) 1.00 (25.4)
NC-25-S .44 (11.2) .50 (12.7) 1.03 (26.2) .97 (24.6) 1.19 (30.2)
SEQUENCE
NC-30-S .50 (12.7) .56 (14.2) 1.03 (26.2) 1.19 (30.2) 1.44 (36.6)
( ) Parentheses = Millimeters NC-35-S .69 (17.5) .75 (19.1) 1.03 (26.2) 1.31 (33.3) 1.63 (41.4)
HOW TO ORDER
SHUTTLE
NC - ** - S
DIRECTIONAL
VALVES
NEEDLE VALVE S = Carbon Steel
SIZE
10 = 1/8"
ACCESSORIES
20 = 1/4"
25 = 3/8"
30 = 1/2"
35 = 3/4"
TECHNICAL
DATA
4.04.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 106
Needle Valve
SERIES S
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
The S-210, S-310, and S-410 series of valves will allow flow in
either direction.
RELIEF
SPECIFICATIONS
*Operating Pressure: 5000 PSI (345 Bar)
Flow: See FLOW CHARACTERISTICS chart.
Temperature: -30F to +250F (-34C to +121C)
SHUTTLE
FLOW CHARACTERISTICS
FLOW CV
MODEL MAX. RECOMENDED FLOW FACTOR
GPM (L/min.) (FULL OPEN)
02/11
4.05.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 107
SOLENOID
Needle Valve
SERIES S
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
2.50
(63.5)
CONTROL
C
FLOW
B
R.38 TYP. (9.7)
RELIEF
.31 TYP. (7.9)
PRESSURE
CONTROL
A B C D
D MODEL WIDTH ACROSS MAX. TORQUE (CLOSED) (FULL OPEN)
HEX. FLATS FT.-LBS. (Nm)
S-210-S-* .88 (22.4) 20 (27.1) 2.25 (57.2) 2.69 (68.3) 1.00 (25.4)
S-310-S-* 1.00 (25.4) 30 (40.7) 2.75 (69.9) 3.25 (82.6) 1.19 (30.2)
S-410-S-* 1.25 (31.8) 40 (54.2) 2.38 (60.5) 2.88 (73.2) 1.56 (39.6)
SEQUENCE
SM-210-S-* .88 (22.4) 20 (27.1) 2.25 (57.2) 2.69 (68.3) 1.00 (25.4)
SM-310-S-* 1.00 (25.4) 30 (40.7) 2.75 (69.9) 3.25 (82.6) 1.19 (30.2)
( ) Parentheses = Millimeters
SM-410-S-* 1.25 (31.8) 40 (54.2) 2.38 (60.5) 2.88 (73.2) 1.56 (39.6)
HOW TO ORDER
SHUTTLE
S * - *** - S - *
DIRECTIONAL
SHUT-OFF VALVE
VALVES
SEALS
3 = Urethane
M = Fine Metering
Needle Valve
(Omit for standard)
ACCESSORIES
SIZE
210 = 1/4"
310 = 3/8"
410 = 1/2"
TECHNICAL
DATA
S = Carbon Steel
4.05.2
E1771 DRNV-100-N-6-C3 spread:Deltrol2004Run8 3/6/11 9:12 PM Page 1
DRNV-100
Rotary,
SOLENOID
Flow Control
SERIES 10
CHECK
CCW
DESCRIPTION
TO OPEN
directions.
MOTION
OPERATION
CONTROL
FLOW
Compact size.
SPECIFICATIONS
SEQUENCE
TO
150 ssu/32 cSt OIL @ 100F/38C
50 (3.4)
PRESSURE DROP psi (bar)
25 (1.7)
TECHNICAL
DATA
0
0 1.0 2.0 3.0 4.0 5.0 6.0
(3.8) (7.6) (11.4) (15.2) (19.0) (22.8)
FLOW gpm (L/min.)
E1771 01/11
4.07.1
E1771 DRNV-100-N-6-C3 spread:Deltrol2004Run8 3/6/11 9:12 PM Page 2
DRNV-100
Rotary,
SOLENOID
Flow Control
SERIES 10
CHECK
INSTALLATION DIMENSIONS
COUNTER-CLOCKWISE
CONTROL
MOTION
TO OPEN
CONTROL
(40.7 Nm) MAX.
FLOW
2.00
(50.8)
.75
(19.2)
RELIEF
1.50
(33.1)
2.00 .28 TYP.
(50.8) (7.1)
PRESSURE
CONTROL
1.25
(31.8)
.13 1.62 (41.4) .63
(3.3) (15.9)
2.00 (50.3)
1.25
(31.8)
SEQUENCE
( ) Parentheses = Millimeters
SHUTTLE
HOW TO ORDER
DRNV - 100 - * - ** - **
ROTARY NEEDLE
DIRECTIONAL
VALVE PORTING
VALVES
4T = SAE 4
CAVITY/SEAL 6T = SAE 6
Omit for cartridge only
FLOW RATE
ACCESSORIES
SEALS
N = Buna-N
TECHNICAL
V = Viton
DATA
4.07.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 108
ZFC-62
Flow Control, Check Valve
SOLENOID
ZERO PROFILE
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
FEATURES and BENEFITS
Slip in style.
PRESSURE
CONTROL
Compact size.
USASI ISO SPECIFICATIONS
SEQUENCE
Operating Pressure: 3000 PSI (207 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
Bias-Spring: 5 PSI (0.3 Bar)
Temperature: -30F to +250F (-35C to +120C)
SHUTTLE
VALVES
40 (2.8)
140 (9.7)
20 (1.4)
ACCESSORIES
120 (8.3)
PRESSURE DROP psi (bar)
0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
100 (6.9) (1.8) (3.8) (5.7) (7.6) (9.5) (11.4) (13.3) (15.2)
60 (4.1)
40 (2.8)
TECHNICAL
20 (1.4)
DATA
0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
(1.8) (3.8) (5.7) (7.6) (9.5) (11.4) (13.3) (15.2)
FLOW gpm (L/min.)
10202-20 02/11
4.10.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 109
ZFC-62
Flow Control, Check Valve
SOLENOID
With Fixed Orifice
ZERO PROFILE
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
#6 SAE PLUG
.482
(12.2)
CONTROL
.75
FLOW
(19.2)
.842
(21.4) 2.11 2.00
(53.5) (50.8)
RELIEF
.50
(12.7) .28 TYP.
PRESSURE
CONTROL
(7.1)
1.50
(38.1) .50
(12.7)
.25 1.00
(6.4) (25.4) 1.00
2.00 (25.4)
SEQUENCE
(50.8)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
ZFC - 62 - U - *** - **
DIRECTIONAL
FLOW CONTROL
VALVES
VALVE
PORTING
CAVITY 4T = SAE 4
6T = SAE 6
Omit for Cartridge Only.
SEALS
U = URETHANE
ACCESSORIES
ORIFICE DIAMETER
015 = .015 (.38)
031 = .031 (.79)
062 = .062 (1.57)
TECHNICAL
4.10.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 110
DFC-080
Adjustable,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
A cartridge valve designed to provide variable flow restriction in one
CONTROL
OPERATION
CONTROL
FLOW
SPECIFICATIONS
0.6
0.4
0.2
ACCESSORIES
0
0 1 2 3 4 5
NUMBER OF TURNS OPEN
Cv P1 P2
TECHNICAL
FLOW IN GPM =
Gf
DATA
10129-00 03/11
4.11.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 111
DFC-080
Adjustable,
SOLENOID
Flow Control Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.26 (6.6) MAX. TRAVEL .26 (6.6) MAX. TRAVEL
1.50 (38.1) DIA. KNOB
CONTROL
1.53
FLOW
(38.9)
.88 (22.4) HEX.
TORQUE 20 FT.- LBS.
(27.1 Nm) MAX.
RELIEF
3.53 .59
(89.7) (15.0)
1.07
(27.2) 1.50
(38.1) 2.00
(50.8)
PRESSURE
CONTROL
.28 TYP.
(7.1)
.56
1.25
(14.2)
SEQUENCE
(31.8)
.13 1.63
(41.4) 1.13
(3.3) 2.00 (28.7)
( ) Parentheses = Millimeters (50.8)
HOW TO ORDER
SHUTTLE
DFC - 080 - * - K - **
DIRECTIONAL
VALVES
NEEDLE VALVE
PORTING
CAVITY/SEAL 2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
ACCESSORIES
SEALS 8T = SAE 8
N = Buna N Omit for Cartridge Only.
V = Viton (Other porting options available
consult factory.)
K = Knob
TECHNICAL
DATA
4.11.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 112
DFC-100
Adjustable, Flow Control Valve
SOLENOID
SERIES 10
CHECK
DESCRIPTION
A cartridge valve designed to provide variable flow restriction in one
CONTROL
OPERATION
CONTROL
FLOW
SPECIFICATIONS
1.8
alloy rated at 3000 PSI (207 Bar).
1.5
Cv FACTOR
1.2
0.9
0.6
ACCESSORIES
0.3
0
0 1 2 3 4 5 6 7
NUMBER OF TURNS OPEN
FLOW IN GPM = Cv P1 - P2
Gf
C v P1 P2
FLOW IN GPM =
Gf
TECHNICAL
DATA
10129-01 02/11
4.12.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 113
DFC-100
Adjustable, Flow Control Valve
SOLENOID
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
1.50 (38.1) DIA. KNOB
1.72
CONTROL
(43.7) 1.00 (25.4) HEX.
FLOW
TORQUE
30 FT. LBS.
(40.7 Nm) MAX.
3.72
3.72
(94.5)
(94.5)
.75
RELIEF
1.28 (19.1)
(32.5) 1.50
(38.1) 2.00
(50.8)
PRESSURE
CONTROL
.28 TYP.
(7.1)
1.25 .63
(31.8) (16.0)
.13 1.63 1.25
(31.8)
SEQUENCE
(3.3) (41.4)
2.00
( ) Parentheses = Millimeters (50.8)
HOW TO ORDER
SHUTTLE
DFC - 100 - * - K - **
DIRECTIONAL
VALVES
FLOW CONTROL PORTING
VALVE 2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
8T = SAE 8
CAVITY/SEAL Omit for Cartridge Only
(Other porting
ACCESSORIES
options available -
consult factory).
SEALS
N = Buna N
V = Viton
TECHNICAL
DATA
K = Knob
4.12.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 114
PCM 88
Fixed, Free Reverse, Externally Ported
SOLENOID
IN-LINE
CHECK
DESCRIPTION
1.
wide variety of flow applications. (2
IN
The male outlet port allows for quick installlation into existing manifolds .7
(11
for meter-in control with free flow in the opposite direction. (2
CONTROL
IN
FLOW
(1
OPERATION
RELIEF
force to throttle the flow and maintain the flow setting. In the reverse
OUT direction the spool shifts to permit free flow.
IN IN
Pressure-compensated.
USASI ISO Quiet response.
IN
OUT IN
OUT Free-reverse.
Industry common cavity.
PRESSURE DROP VS. FLOW Compact size.
SHUTTLE
OUT OUT
IN TO OUT (REGULATED)
150 ssu/32 cSt OIL @ 100F/38C
5.0 gpm(18.9L/min.) VALVE
FLOW CURVES TYP. FOR OTHER SIZES
10.0 (37.9) SPECIFICATIONS
IN TO OUT (REGULATED)
DIRECTIONAL
2.0 (7.6)
Flow Tolerances: Flows up to and including
6.0 (22.7)
1.5 gpm (5.7 L/min.) 15%
0
4.0 (15.1)
0 500 1000 1500 2000 2500 3000 Flows over 1.5 gpm (5.7 L/min.) 10%
ACCESSORIES
2.0 (7.6)
(34.5) (69.0) (103.4) (137.9) (172.4) (206.9) Temperature: -30F to +250F (-35C to +120C)
PRESSURE DROP psi(bar) Recommended Filtration: ISO 17/15/13
0
0 500 1000 1500IN TO2000
OUT 2500 3000 Fluids: Mineral-based fluids.
(34.5) (69.0) (103.4) TO IN (172.4) (206.9)
OUT(137.9) For other fluid compatibility, consult factory.
PRESSURE DIFFERENTIAL
OUTLET TO INLET psi (bar)
400(27.6)
PRESSURE DROP psi(bar) Cavity: #8 SAE, see page 4.13.2
300(20.7)
IN TO OUT
Optional Cavity/Cavity Tool: 080-2, see page 11.08.02
200(13.8) OUT TO IN In-Line Body Material: Anodized 6061 T6 aluminum
PRESSURE DIFFERENTIAL
OUTLET TO INLET psi (bar)
TECHNICAL
400(27.6)
100(6.9) alloy rated at 3000 PSI (207 Bar).
DATA
300(20.7)
0
200(13.8)0 2.0 4.0 6.0 8.0 10.0
(7.6) (15.1) (22.7) (30.3) (37.9)
100(6.9)
REVERSE FLOW gpm(L/min.)
0
0 2.0 4.0 6.0 8.0 10.0
(7.6) (15.1) (22.7) (30.3) (37.9) 10166-85 02/11
REVERSE FLOW gpm(L/min.)
4.13.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 115
PCM 88
Fixed, Free Reverse, Externally Ported
SOLENOID
Pressure-Compensated Flow Regulator Valve
IN-LINE
CHECK
INSTALLATION DIMENSIONS
CONTROLLED FLOW
CONTROL
MOTION
3/4-16UNF-2B
#8 SAE O-RING BOSS
IN 1.00 (25.4) HEX. IN
CONTROL
TORQUE 20FT.-LBS.
FLOW
1.00 (27.1Nm) MAX.
(25.4)
RELIEF
FREE FLOW 1.50 OUT
OUT (38.1) 2.00
(50.8)
3/4-16UNF-2B
#8 SAE O-RING BOSS
.28TYP.
PRESSURE
CONTROL
(7.1)
OUT
.750(19.1) 1.25 .56
MINIMUM (31.8) (14.2)
.13 1.63 1.13
(3.3) (41.4) (28.7)
2.00
(50.8)
.375(9.5)
SEQUENCE
MINIMUM
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
PCM 88 - * - **** - **
PORTING
DIRECTIONAL
2N = 1/4 PTF
VALVES
3N = 3/8 PTF
4T = SAE 4
6T = SAE 6
Omit for Cartridge Only.
FLOW REGULATOR VALVE (Other porting options available
consult factory.) ACCESSORIES
4.13.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 116
LLPC
Fixed, Free Reverse, Externally Ported Pressure-
SOLENOID
IN-LINE
CHECK
DESCRIPTION
flow applications.
The male outlet port allows for quick installlation into existing manifolds
OUT for meter-in control with free flow in the opposite direction.
CONTROL
FLOW
OUT
OPERATION
2.1
(54
RELIEF
force to throttle the flow and maintain the flow setting. In the reverse 1.7
(38
direction the spool shifts to permit free flow. 1.
IN (38
IN
FEATURES and BENEFITS
SEQUENCE
Pressure-compensated.
USASI ISO Quiet response.
OUT OUT
USASI ISO Free-reverse.
OUT OUT Compact size.
SHUTTLE
IN IN
PRESSURE
IN DROP
IN VS. FLOW
SPECIFICATIONS
150 ssu/32 cSt OIL @ 100F/38C
DIRECTIONAL
16.0 (60.6)
20.0 (75.7)
12.0
17 gpm (64.3 L/min.)
16.0 (45.4)
gpm (L/min.)
(60.6)
24 gpm (90.8 L/min.)
8.0 (30.3)
12.0 (45.4) Flow Tolerances: All valves +5%-15%
FLOWFLOW
4.0 (15.1)
8.0 (30.3) Temperature: -30F to +250F (-35C to +120C)
ACCESSORIES
0
4.0 (15.1) Recommended Filtration: ISO 17/15/13
0 500 1000 1500 2000 2500 3000
(34.5) (69.0) (103.4) (137.9) (172.4) (206.9) Fluids: Mineral-based fluids.
0
0 500 1000 1500 2000 2500 3000 For other fluid compatibility, consult factory.
DIFFERENTIAL
psi (bar)
60
80 (4.1)
(5.5)
TO INLET
40
60 (2.8)
(4.1)
TO INLET
PRESSURE
TECHNICAL
20
40 (1.4)
OUTLET
(2.8)
PRESSURE
DATA
0
20 (1.4)
OUTLET
4.14.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 117
LLPC
Fixed, Free Reverse, Externally Ported
SOLENOID
Pressure-Compensated Flow Regulator Valve
IN-LINE
CHECK
INSTALLATION DIMENSIONS
FREE FLOW
CONTROL
MOTION
OUT
1.062 (27.0) 1 3/16-12UN-2B
3/4-16UNF-2B MINIMUM #14 SAE O-RING BOSS.
#8 SAE O-RING BOSS.
CONTROL
FLOW
1.38 (35.1) HEX.
2.13 TORQUE 70 FT.-LBS.
(54.1) (94.9 Nm) MAX. 2.00 (50.8)
MINIMUM
RELIEF
1.75 .750 (19.1)
(38.1) MINIMUM
CONTROLLED
FLOW
PRESSURE
CONTROL
RECOMMENDED CAVITY
IN
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
LLPC - * - **
DIRECTIONAL
VALVES
LOAD LOWERING NOMINAL FLOW SETTING
FLOW REGULATOR VALVE 8 = 8.00 GPM (30.3 L/min.)
12 = 12.00 GPM (45.4 L/min.)
17 = 17.00 GPM (64.3 L/min.)
24 = 24.00 GPM (90.8 L/min.)
ACCESSORIES
SEALS
N = Buna N
V = Viton
TECHNICAL
DATA
4.14.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 118
DFR-080-2
Fixed, Pressure-Compensated
SOLENOID
SERIES 8
CHECK
DESCRIPTION
A fixed cartridge valve designed to regulate flow regardless of load
CONTROL
flow applications.
CONTROL
OPERATION
FLOW
spool control orifice, the spool shifts against the spring force to throttle
the flow and maintain the flow setting. Reverse flow is not regulated.
PRESSURE
CONTROL
FEATURES and BENEFITS
Pressure-compensated.
Quiet response.
SEQUENCE
SPECIFICATIONS
Flow: Ranges from 0.1 gpm to 2.0 gpm (0.4 to 7.6 L/min.)
VALVES
.50 (1.9)
alloy rated at 3000 PSI (207 Bar).
.40 (1.5)
.30 (1.1)
.20 (.8)
TECHNICAL
.10 (.4)
DATA
0
0 500 1000 1500 2000 2500 3000
(34.5) (69.0) (103.4) (137.9) (172.4) (206.9)
10140-54 02/11
4.23.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 119
DFR-080-2
Fixed, Pressure-Compensated
SOLENOID
Flow Regulator Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.88 (22.4) HEX.
TORQUE 20 FT.-LBS. .59
(27.1 Nm) MAX. (15.0)
CONTROL
1.50
FLOW
(38.1) 2.37
.37 (60.2) 2.00
(9.4) (50.8)
RELIEF
1.06
(26.9)
.28 TYP.
(7.1)
PRESSURE
CONTROL
1.25 .56
1.63
(31.8) (14.2)
.13 1.13
(3.3) (41.4) (28.7)
2.00
(50.8)
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DFR - 080 - 2 - * - *** - **
PORTING
2N = 1/4 PTF
FLOW REGULATOR VALVE 3N = 3/8 PTF
DIRECTIONAL
(FIXED) 4T = SAE 4
VALVES
6T = SAE 6
Omit for Cartridge Only.
(Other porting options available
CAVITY/SEAL consult factory.)
4.23.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 120
DFRA-080-2
Adjustable, Pressure-Compensated
SOLENOID
SERIES 8
CHECK
DESCRIPTION
An adjustable cartridge valve designed to regulate flow regardless of
CONTROL
OPERATION
FLOW
compensator spool control orifice, the spool shifts against the spring
force to throttle the flow and maintain the flow setting. The cartridges
flow may be adjusted -50% of maximum setting. Reverse flow is not
regulated.
PRESSURE
CONTROL
Pressure-compensated.
Quiet response.
Low flow capabilities.
Aluminum knob and disc nut.
Adjustable flow -50% of maximum setting.
Adjustment may be locked in place.
SHUTTLE
SPECIFICATIONS
VALVES
.50 (1.9)
Recommended Filtration: ISO 17/15/13
.40 (1.5)
Fluids: Mineral-based fluids.
.30 (1.1)
For other fluid compatibility, consult factory.
.20 (.8)
TECHNICAL
10133-46 02/11
4.24.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 121
DFRA-080-2
Adjustable, Pressure-Compensated
SOLENOID
Flow Regulator Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
.19 (4.8) MAX. TRAVEL .19 (4.8) MAX. TRAVEL
MOTION
.75 (19.1) DIA. KNOB
1.14
CONTROL
(29.0)
FLOW
.88 (22.4) HEX.
TORQUE 20 FT.- LBS.
(27.1 Nm) MAX.
3.14 .59
(79.8)
RELIEF
(15.0)
1.06
(26.9) 1.50
(38.1)
2.00
(50.8)
PRESSURE
CONTROL
.28 TYP.
(7.1)
1.25
SEQUENCE
.13 (31.8) .56
1.63 (14.2)
(3.3) (41.4) 1.13
( ) Parentheses = Millimeters 2.00 (28.7)
(50.8)
HOW TO ORDER
SHUTTLE
DFRA - 080 - 2 - * - *** - **
DIRECTIONAL
FLOW REGULATOR VALVE
PORTING
VALVES
(ADJUSTABLE)
2N = 1/4 PTF
3N = 3/8 PTF
4T = SAE 4
6T = SAE 6
CAVITY/SEAL Omit for Cartridge Only.
(Other porting options available
consult factory.)
ACCESSORIES
FLOW PATH
MAXIMUM FLOW SETTING
015 = .15 GPM ( .57 L/min.)
020 = .20 GPM ( .76 L/min.)
SEALS
045 = .45 GPM (1.70 L/min.)
TECHNICAL
N = Buna N
065 = .65 GPM (2.46 L/min.)
V = Viton
DATA
4.24.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 122
DFRA-100-2
Adjustable, Pressure-Compensated
SOLENOID
SERIES 10
CHECK
DESCRIPTION
An adjustable cartridge valve designed to regulate flow regardless of
CONTROL
OPERATION
CONTROL
FLOW
compensator spool control orifice, the spool shifts against the spring
force to throttle the flow and maintain the flow setting. The cartridges
flow may be adjusted - 50% of maximum setting. Reverse flow is not
regulated.
PRESSURE
CONTROL
Pressure-compensated.
SEQUENCE
Quiet response.
Hidden adjustment (tamper resistant) option.
Aluminum knob and disc nut option.
Adjustable flow - 50% of maximum setting.
Adjustment may be locked in place.
SHUTTLE
SPECIFICATIONS
DIRECTIONAL
VALVES
PRESSURE DROP VS. FLOW Operating Pressure: 3000 PSI (207 Bar).
Flow: Ranges from 1 to 10 gpm (3.8 to 37.9 L/min.)
(See ordering table)
Flow may be adjusted -50% of maximum setting.
9.0 (34.1)
Flow Tolerances: Flows up to and including
1.5 gpm (5.7 L/min.) +15%
ACCESSORIES
MAX. ADJUSTMENT
8.0 (30.3)
7.0 (26.5)
Flows over 1.5 gpm (5.7 L/min.) +10%
Temperature: -30 F to +250 F (-35C to +120 C)
FLOW gpm (L/min.)
6.0 (22.7)
1.0 (3.8)
In-Line Body Material: Anodized 6061T6 aluminum
DATA
0
alloy rated at 3000 PSI (207 Bar).
0 500 1000 1500 2000 2500 3000
(34.5) (69.0) (103.4) (137.9) (172.4) (206.9)
10132-92 02/11
4.26.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 123
DFRA-100-2
Adjustable, Pressure-Compensated
SOLENOID
Flow Regulator Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
SCREW ADJUSTMENT KNOB ADJUSTMENT HIDDEN ADJUSTMENT
1/4" HEX. SOCKET 1.50 (38.1) DIA. KNOB 5/16" HEX. SOCKET
CONTROL
FLOW
2.32
(58.9)
5.19
(131.8)
3.19 MAX.
(81.0)
MAX
RELIEF
.75
1.00 (25.4) HEX. (19.1)
TORQUE 1.50
30 FT. - LBS. (38.1) 2.00
(40.7 Nm) MAX. (50.8)
PRESSURE
CONTROL
.28 TYP.
1.30 (7.1)
(33.0) .63
1.25
(31.8) (16.0)
.13 1.63 1.25
(3.3) (41.4) (31.8)
2.00
SEQUENCE
(50.8)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DFRA - 100 - 2 - * - * - **** - **
PORTING
FLOW REGULATOR VALVE
DIRECTIONAL
2N = 1/4 PTF
(ADJUSTABLE) 3N = 3/8 PTF
VALVES
6T = SAE 6
8T = SAE 8
CAVITY/SEAL Omit for Cartridge Only.
(Other porting options available
consult factory.)
FLOW PATH
ACCESSORIES
SEALS
N = Buna N MAXIMUM FLOW SETTING
V = Viton
100 = 1.00 GPM (3.79 L/min.)
150 = 1.50 GPM (5.68 L/min.)
200 = 2.00 GPM (7.57 L/min.)
ADJUSTMENT STYLE 300 = 3.00 GPM (11.36 L/min.)
TECHNICAL
4.26.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 124
DFR-100-3
Fixed, Bypass-Type, Pressure-Compensated
SOLENOID
SERIES 10
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
spring force to throttle the flow and maintain the priority flow setting.
Reserve flow is not regulated.
PRESSURE
CONTROL
Pressure-compensated.
Quiet response.
Bypass port may be fully pressurized.
SEQUENCE
SPECIFICATIONS
Operating Pressure: 3000 PSI (207 Bar). A minimum pressure differtial
of 100 PSID is required to operate valve.
Flow: Ranges from 1 to 6 gpm (3.8 to 22.7 L/min.)
10 gpm (37.9 L/min.) max. input.
DIRECTIONAL
8.0 (30.3)
6.0 (22.7)
4.0 (15.1)
TECHNICAL
2.0 (7.6)
DATA
0
0 500 1000 1500 2000 2500 3000
(34.5) (69.0) (103.4) (137.9) (172.4) (206.9)
PRESSURE DROP psi (bar)
SURE DIFFERENTIAL
10183-70 02/11
200 (13.8)
4.30.1
psi (bar)
100 (6.9)
TO
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 125
DFR-100-3
Fixed, Bypass-Type, Pressure-Compensated
SOLENOID
Flow Regulator Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
1.00 (25.4) HEX.
TORQUE
30 FT.-LBS.
(40.7 Nm) MAX.
CONTROL
.75 (19.1) .75
FLOW
(19.1)
1.38 3.38
(35.1) (85.9)
2.13
(54.1)
2.63
(66.8)
1.82
RELIEF
(46.2)
.28 TYP.
(7.1)
PRESSURE
CONTROL
1.25 .63
(31.8) (16.0)
.25 2.00
(50.8) 1.25
(6.4) (31.8)
2.50
(63.5)
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DFR - 100 - 3 - * - **** - **
DIRECTIONAL
PORTING
VALVES
FLOW REGULATOR VALVE 2N = 1/4 PTF
(FIXED) 3N = 3/8 PTF
6T = SAE 6
8T = SAE 8
Omit for Cartridge Only.
CAVITY/SEAL (Other porting options available
consult factory.)
ACCESSORIES
4.30.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:33 PM Page 126
DFRA-100-3
Adjustable, Bypass-Type, Pressure-Compensated
SOLENOID
SERIES 10
CHECK
DESCRIPTION
An adjustable bypass-type cartridge valve designed to regulate priority
flow while bypassing excess flow regardless of load pressure.
CONTROL
MOTION
OPERATION
CONTROL
FLOW
spring force to throttle the flow and maintain the priority flow setting. The
cartridges flow may be adjusted -40% of maximum setting. Reverse flow
is not regulated.
PRESSURE
CONTROL
Pressure-compensated.
SEQUENCE
Quiet response.
Bypass port may be fully pressurized.
Hidden adjustment (tamper resistant) option.
Aluminum knob and disc nut option.
Adjustment may be locked in place.
SHUTTLE
SPECIFICATIONS
DIRECTIONAL
VALVES
MAX.
6.0 (22.7) MID. Fluids: Mineral-based fluids.
MIN. ADJUSTMENT
4.0 (15.1) For other fluid compatibility consult factory.
Cavity/Cavity Tool: 100-3, see page 11.10.3
TECHNICAL
2.0 (7.6)
In-Line Body Material: Anodized 6061T6 aluminum
DATA
0
alloy rated at 3000 PSI (207 Bar).
0 500 1000 1500 2000 2500 3000
(34.5) (69.0) (103.4) (137.9) (172.4) (206.9)
PRESSURE DROP psi (bar)
SURE DIFFERENTIAL
10134-42 02/11
TO psi (bar)
200 (13.8)
4.31.1
MAX.
100 (6.9)
MIN. ADJUSTMENT
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 127
DFRA-100-3
Adjustable, Bypass-Type, Pressure-Compensated
SOLENOID
Flow Regulator Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
HIDDEN ADJUSTMENT
KNOB ADJUSTMENT .31 (7.9) HEX. SOCKET
SCREW ADJUSTMENT 1.50 (38.1) DIA. KNOB
CONTROL
MOTION
.25 (6.4) HEX. SOCKET
2.32
CONTROL
(58.9)
FLOW
5.82
(147.8)
3.19 MAX.
(81.0)
MAX.
1.00 (25.4) HEX.
.75
RELIEF
TORQUE (19.1)
1.38
30 FT. LBS. (35.1)
(40.7 Nm) MAX.
2.13
(54.1) 2.63
(66.8)
PRESSURE
CONTROL
1.82
(46.2)
.28 TYP.
(7.1)
1.25 .63
(31.8) (16.0)
SEQUENCE
.25 2.00 1.25
(6.4) (50.8) (31.8)
2.50
( ) Parentheses = Millimeters (63.5)
HOW TO ORDER
SHUTTLE
DFRA - 100 - 3 - * - * - **** - **
DIRECTIONAL
PORTING
FLOW REGULATOR VALVE 2N = 1/4 PTF
VALVES
(ADJUSTABLE) 3N = 3/8 PTF
6T = SAE 6
8T = SAE 8
CAVITY/SEAL Omit for Cartridge Only.
(Other porting options available
consult factory.)
FLOW PATH
ACCESSORIES
SEALS
N = Buna N MAXIMUM FLOW SETTING
V = Viton
100 = 1.00 GPM (3.79 L/min.)
150 = 1.50 GPM (5.68 L/min.)
200 = 2.00 GPM (7.57 L/min.)
TECHNICAL
4.31.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 128
DFR-120-3
Fixed, Bypass-Type, Pressure-Compensated
SOLENOID
SERIES 12
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
spring force to throttle the flow and maintain the priority flow setting.
Reverse flow is not regulated.
PRESSURE
CONTROL
SPECIFICATIONS
SHUTTLE
12.0 (45.4)
6.0 (22.7)
TECHNICAL
2.0 (7.6)
0
0 500 1000 1500 2000 2500 3000
(34.5) (69.0) (103.4) (137.9) (172.4) (206.9)
PRESSURE DROP psi (bar)
E DIFFERENTIAL
10145-04 02/11
100 (6.9)
O
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 129
DFR-120-3
Fixed, Bypass-Type, Pressure-Compensated
SOLENOID
Flow Regulator Valve
SERIES 12
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
1.25 (31.8) HEX.
1.10 TORQUE
(27.9) 60 FT.-LBS.
(81.3 Nm) MAX.
CONTROL
FLOWRELIEF
2.78
(70.6)
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DFR - 120 - 3 - * - ****
DIRECTIONAL
VALVES
FLOW REGULATOR VALVE MAXIMUM FLOW SETTING
(FIXED)
200 = 2.00 GPM (7.57 L/min.)
225 = 2.25 GPM (8.52 L/min.)
250 = 2.50 GPM (9.46 L/min.)
300 = 3.00 GPM (11.36 L/min.)
360 = 3.60 GPM (13.63 L/min.)
CAVITY/SEAL 400 = 4.00 GPM (15.14 L/min.)
ACCESSORIES
SEALS
DATA
N = Buna N
V = Viton
4.32.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 130
DFD-100
Pressure-Compensated,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
In the dividing mode, the DFD-100 will split the input flow from port to
ports and per the ratio specified.
The DFD-100 will combine input flows from ports and to a common
RELIEF
port .
This valve has no port function.
PRESSURE
CONTROL
FEATURES and BENEFITS
Pressure-compensated.
Quiet response.
SEQUENCE
300 (20.7)
3.0-5/5 Operating Pressure: 3000 PSI (207 Bar) A minimum pressure
250 (17.2)
6.0-5/5
differential of 40 psid is required to operate valve.
9.0-5/5
DIRECTIONAL
200 (13.8) Flow: See max. rated input flow in ordering table.
Flow Tolerances: +10% from 30-100% of rated flow for all 5/5 models
VALVES
150 (10.3)
100 (6.9)
except 16.0-5/5 which is +10% from 40-100% of
50 (3.4)
rated flow. (Consult factory for all other models.)
Temperature: -30 F to +250 F (-35C to +120 C)
0
0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 Recommended Filtration: ISO 17/15/13
(3.8) (7.6) (11.4)(15.1)(18.9)(22.7)(26.5)(30.3)(34.1)
300 (20.7)
250 (17.2)
alloy rated at 3000 PSI (207 Bar).
12.0-5/5 16.0-5/5
200 (13.8)
150 (10.3)
TECHNICAL
100 (6.9)
DATA
50 (3.4)
0
0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0
(7.6) (15.1) (22.7) (30.3) (37.9) (45.4) (53.0) (60.6)
10138-22 02/11
4.40.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 131
DFD-100
Pressure-Compensated,
SOLENOID
Flow Divider/Combiner Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
.38
MOTION
(9.7)
1.00 (25.4) HEX
TORQUE 40 FT.LBS.
(40.7 Nm) MAX.
.75
(19.1)
CONTROL
1.38
FLOW
(35.1)
2.00
2.52 (50.8)
(64.0)
3.25
2.88 (82.6)
RELIEF
(73.2)
3.63
(92.2)
PRESSURE
CONTROL
SPRING RETAINER
MUST NOT BE COCKED .28 TYP.
DURING INSTALATION
(7.1)
.63
(16.0)
.25 2.00 1.25
(6.4) (50.8)
SEQUENCE
(31.8)
2.50
(63.5)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DFD - 100 - * - **** - */ * - **
FLOW DIVIDER/ PORTING (Use special
DIRECTIONAL
COMBINER VALVE 2N = 1/4 PTF flow divider
bodies with
VALVES
3N = 3/8 PTF
CAVITY/SEAL 6T = SAE 6 no port .)
8T = SAE 8
SEALS Omit for Cartridge Only.
N = Buna N MAX RATED - DIVIDING OR COMBINING (other porting
V = Viton INPUT FLOW RATIO(PORT 2 / PORT 4) options available
consult factory)
1.6 - 5/5 = 1.6 GPM ( 6.1 L/min.) - 50:50
ACCESSORIES
4.40.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 132
ZRV-63
Adjustable,
SOLENOID
ZERO PROFILE
CHECK
DESCRIPTION
An adjustable, direct-acting poppet cartridge valve designed to limit
CONTROL
OPERATION
CONTROL
FLOW
The ZRV-63 prevents flow from to until the set crack pressure
at is achieved. The poppet then unseats allowing flow from to
protecting the circuit from over pressurization.
RELIEF
SPECIFICATIONS
SEQUENCE
1500 (103)
1000 (69)
TECHNICAL
500 (34)
DATA
0
0 .25 .5 .75 1 1.5 2
(.9) (1.9) (2.8) (3.8) (5.7) (7.6)
10198-93(D) 02/11
5.01.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 133
ZRV-63
Adjustable,
SOLENOID
Direct-Acting Relief Valve
ZERO PROFILE
CHECK
INSTALLATION DIMENSIONS
#6 SAE PLUG
5/64" Wide 1/8" HexAdjustment
Broached
CONTROL
1/8" Screw
Hex
MOTION
Adjustment Adjustment
5/64" Wide
Stabilizer Socket
(not available on
Adjustment
Slots Tamper-Resistant option)
Stabilizer
Slots
9/16-18 THREAD
1.58
CONTROL
9/16-18 THREAD (40.2)
2.25
FLOW
TORQUE 10 FT.-LBS.
(13.6 Nm) MAX. (57.2)
2.84
2.75 (72.2)
(69.9)
RELIEF
1.44
(36.5)
1.56
(39.6) .50
.28 TYP. (12.7)
PRESSURE
CONTROL
(7.1)
1.00
(25.4) .50
1.50 (12.7)
(38.1) 1.00
2.00 (25.4)
(50.8)
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
ZRV - 63 - U - * - ** / **** - **
DIRECTIONAL
RELIEF VALVE
VALVES
PORTING
4T = SAE 4
6T = SAE 6
Omit for Cartridge Only.
CAVITY
ACCESSORIES
5.01.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 134
DRV2-080
Adjustable,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
An adjustable, direct-acting poppet cartridge valve designed to limit
CONTROL
OPERATION
CONTROL
FLOW
The DRV2-080 prevents flow from to until the set crack pressure
at is achieved. The poppet then unseats allowing flow from to
protecting the circuit from over pressurization.
RELIEF
Quiet operation.
PRESSURE
CONTROL
SPECIFICATIONS
SHUTTLE
2500 (172.4)
Preset: 2500 PSI (172 Bar)
PRESSURE DROP psi (bar)
500 (34.5)
DATA
0
2.0 4.0 6.0 8.0 10.0
0 (7.6) (15.1) (22.7) (30.3) (37.9)
10139-59 02/11
5.02.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 135
DRV2-080
Adjustable,
SOLENOID
Direct-Acting Relief Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
SCREW ADJUSTMENT KNOB ADJUSTMENT
.19 (4.8) HEX. SOCKET 1.50 (38.1) DIA. KNOB
CONTROL
FLOW
2.88
(73.2) 4.88
MAX. .88 (22.4) HEX.
TORQUE (124.0)
20 FT.- LBS. MAX.
RELIEF
(27.1 Nm) MAX. .59
1.50 (15.0)
(38.1)
2.00
1.09 (50.8)
PRESSURE
(27.7)
CONTROL
.28 TYP.
(7.1)
1.25
(31.8)
.13 1.63 .56
(3.3) (41.4) (14.2)
1.13
2.00 (28.7)
SEQUENCE
(50.8)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DRV2 - 080 - * - * - *** / **** - **
DIRECTIONAL
RELIEF VALVE PORTING
VALVES
2N = 1/4 PTF
3N = 3/8 PTF
4T = SAE 4
CAVITY/SEAL 6T = SAE 6
Omit for Cartridge Only.
(Other porting
options available
ACCESSORIES
consult factory.)
SEALS
N = Buna-N FACTORY PRESET PSI
V = Viton (Omit for standard)
SPRING RANGE
ADJUSTMENT STYLE 4 = 100 to 400 PSI ( 7 to 28 Bar)
TECHNICAL
5.02.2
DRV-080-*-H
Tamper-Resistant,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
An adjustable, direct-acting poppet cartridge valve designed to limit
CONTROL
OPERATION
CONTROL
FLOW
The DRV-080-*-H prevents flow from to until the set crack pressure
at is achieved. The poppet then unseats allowing flow from to
protecting the circuit from over pressurization.
RELIEF
SPECIFICATIONS
2500 (172.4)
alloy rated at 3000 PSI (207 Bar).
PRESSURE DROP psi (bar)
2000 (137.9)
1500 (103.4)
1000 (69.0)
TECHNICAL
500 (34.5)
DATA
0
2.0 4.0 6.0 8.0 10.0
0 (7.6) (15.1) (22.7) (30.3) (37.9)
10158-13 02/11
5.03.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 137
DRV-080-*-H
Tamper-Resistant,
SOLENOID
Direct-Acting Relief Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.88 (22.4) HEX.
TORQUE
20 FT.-LBS.
(27.1 Nm) MAX.
CONTROL
1.25
FLOW
(31.8) 3.25 .59
(82.6) (15.0)
1.50
(38.1) 2.00
(50.8)
RELIEF
1.09
(27.7)
.28 TYP.
(7.1)
PRESSURE
CONTROL
1.25 .56
(31.8) (14.2)
.13 1.63 1.13
(3.3) (41.4) (28.7)
2.00
(50.8)
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DRV - 080 - * - H - 30/ **** - **
DIRECTIONAL
RELIEF VALVE PORTING
VALVES
2N = 1/4 PTF
3N = 3/8 PTF
4T = SAE 4
CAVITY/SEAL 6T = SAE 6
Omit for Cartridge Only.
(Other porting
options available
ACCESSORIES
consult factory.)
SEALS
N = Buna-N FACTORY PRESET PSI
V = Viton 50 psi Increments
example: 2550 = 2550 PSI
(Omit for standard)
HIDDEN
TECHNICAL
5.03.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 138
DRV-100
Adjustable,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
An adjustable, direct-acting poppet cartridge valve designed to limit
CONTROL
OPERATION
CONTROL
FLOW
The DRV-100 prevents flow from to until the set crack pressure
at is achieved. The poppet then unseats allowing flow from to
protecting the circuit from over pressurization. SCREW
.25 (6.4)
RELIEF
1
(3
SPECIFICATIONS
SHUTTLE
Operating Pressure: 3000 PSI (207 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
Nominal Flow 10 GPM (37.9 L/min).
Internal Leakage: 20 drops/min. max. at reseat.
DIRECTIONAL
3000 (206.9)
Preset: 1500 PSI (103 Bar)
2500 (172.4) 1500 to 3000 PSI (103 to 207 Bar)
PRESSURE DROP psi (bar)
0
alloy rated at 3000 PSI (207 Bar).
2.0 4.0 6.0 8.0 10.0
0 (7.6) (15.1) (22.7) (30.3) (37.9)
10138-01 02/11
5.04.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 139
DRV-100
Adjustable,
SOLENOID
Direct-Acting Relief Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
HIDDEN ADJUSTMENT
.31 (7.9) HEX SOCKET
CONTROL
MOTION
SCREW ADJUSTMENT KNOB ADJUSTMENT
.25 (6.4) HEX SOCKET 1.50 (38.1) DIA. KNOB
CONTROL
2.32
FLOW
(58.9)
5.19
3.19 (131.8)
(81.0) MAX.
MAX. 1.00 (25.4) HEX .75
RELIEF
TORQUE (19.0)
30 FT-LBS. 1.50
(40.7 Nm) MAX. (38.1) 2.00
(50.8)
PRESSURE
CONTROL
.28 TYP.
1.25 (7.1)
(31.8) 1.25
(31.8)
1.63 .63
.13 (16.0)
(3.3) (41.4)
2.00 1.25
SEQUENCE
(50.8) (31.8)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DRV - 100 - * - * - ** / **** - **
RELIEF VALVE
DIRECTIONAL
PORTING
VALVES
2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
CAVITY/SEAL
8T = SAE 8
Omit for Cartridge Only.
(Other porting
options available
consult factory.)
ACCESSORIES
SEALS
N = Buna N
V = Viton FACTORY PRESET PSI
(Omit for standard)
SPRING RANGE
ADJUSTMENT STYLE 4 = 100 to 400 PSI ( 7 to 28 Bar)
H = Hidden Preset: 300 PSI ( 21 Bar)
K = Knob 10 = 300 to 1000 PSI ( 21 to 69 Bar)
TECHNICAL
5.04.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 140
ZDRV-63
Adjustable, Direct-Acting,
SOLENOID
ZERO PROFILE
CHECK
DESCRIPTION
An adjustable, direct-acting poppet cartridge valve designed to limit
CONTROL
OPERATION
CONTROL
FLOW
The ZDRV-63 prevents flow from to until the set crack pressure
at is achieved. The poppet then unseats allowing flow from to
protecting the circuit from over pressurization.
RELIEF
SPECIFICATIONS
SEQUENCE
150 ssu/32 cSt OIL @ 100F/38C Cavity/Cavity Tool: ZP63, see page 11.06.3
Installation/Removal Tool: Consult factory.
In-Line Body Material: Anodized 6061T6 aluminum
alloy rated at 3000 PSI (207 Bar).
TECHNICAL
DATA
10188-54(3) 02/11
5.05.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 141
ZDRV-63
Adjustable, Direct-Acting,
SOLENOID
Differential Area Relief Valve
ZERO PROFILE
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
(not available on Tamper-Resistant option)
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
ZDRV - 63 - U - * - ** / **** - **
DIRECTIONAL
RELIEF VALVE
VALVES
PORTING
4T = SAE 4
6T = SAE 6
Omit for Cartridge Only.
CAVITY
SEALS
U = Urethane
SPRING RANGE
06 = 100 to 600 PSI (7 to 41 Bar)
Preset: 300 PSI (21 Bar)
ADJUSTMENT OPTION
10 = 500 to 1000 PSI (34 to 69 Bar)
(Omit for Standard)
TECHNICAL
5.05.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 142
DDRV-080
Adjustable, Direct-Acting,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
An adjustable, direct-acting poppet cartridge valve designed to limit
CONTROL
OPERATION
CONTROL
FLOW
The DDRV-080 prevents flow from to until the set crack pressure
at is achieved. The poppet then unseats allowing flow from to
protecting the circuit from over pressurization.
RELIEF
SPECIFICATIONS
SHUTTLE
2800 (193.1)
Preset: 2500 PSI (172 Bar)
Temperature: -30F to +250F (-35C to +120C)
2400 (165.6)
Recommended Filtration: ISO 20/18/14
2000 (138.0)
Fluids: Mineral-based fluids. For other fluid compatibility, consult factory.
1600 (110.3) Cavity/Cavity Tool: 080-2, see page 11.08.2
1200 (82.8) In-Line Body Material: Anodized 6061T6 aluminum
alloy rated at 3000 PSI (207 Bar).
TECHNICAL
800 (55.2)
DATA
400 (27.6)
0
0 2 4 6 8 10 12 14 16 18 20
(7.6) (15.1) (22.7) (30.1) (37.9) (45.5) (53.0) (7.6) (60.6) (75.7)
10139-63 02/11
5.06.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 143
DDRV-080
Adjustable, Direct-Acting,
SOLENOID
Differential Area Relief Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
SCREW ADJUSTMENT
CONTROL
MOTION
.19 (4.8) HEX. SOCKET KNOB ADJUSTMENT
1.50 (38.1) DIA. KNOB
CONTROL
FLOW
2.88
(73.2)
MAX. .88 (22.4) HEX.
TORQUE 20 FT.-LBS. 4.88
(27.1 Nm) MAX. (124.0)
RELIEF
MAX.
.59
(15.0)
1.50
(38.1)
2.00
PRESSURE
CONTROL
1.09 (50.8)
(27.7)
.28 TYP.
(7.1)
1.25 .56
(31.8) (14.2)
.13 1.63 1.13
SEQUENCE
(3.3) (41.4) (28.7)
2.00
( ) Parentheses = Millimeters (50.8)
HOW TO ORDER
SHUTTLE
DDRV - 080 - * - * - *** / **** - **
DIFFERENTIAL
DIRECTIONAL
PORTING
AREA RELIEF VALVE
VALVES
2N = 1/4 PTF
3N = 3/8 PTF
4T = SAE 4
6T = SAE 6
Omit for Cartridge Only.
CAVITY/SEAL (Other porting
options available
consult factory.)
ACCESSORIES
ADJUSTMENT STYLE
20 = 300 to 2000 PSI ( 21 to 138 Bar)
K = Knob
Preset: 1500 PSI (103 Bar)
S = Screw
30 = 1500 to 3000 PSI (103 to 207 Bar)
Preset: 2500 PSI (172 Bar)
5.06.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 144
DDRV-080-*-H
Tamper-Resistant, Direct-Acting,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
An adjustable, direct-acting poppet cartridge valve designed to limit
CONTROL
OPERATION
CONTROL
FLOW
The DDRV-080-*-H prevents flow from to until the set crack pressure
at is achieved. The poppet then unseats allowing flow from to
protecting the circuit from over pressurization.
RELIEF
Quiet operation.
PRESSURE
CONTROL
Compact size.
SPECIFICATIONS
SHUTTLE
2800 (193.1)
In-Line Body Material: Anodized 6061T6 aluminum
2400 (165.6)
alloy rated at 3000 PSI (207 Bar).
2000 (138.0)
1600 (110.3)
1200 (82.8)
800 (55.2)
TECHNICAL
400 (27.6)
DATA
0
0 2 4 6 8 10 12 14 16 18 20
(7.6) (15.1) (22.7) (30.1) (37.9) (45.5) (53.0) (7.6) (60.6) (75.7)
10161-70 02/11
5.07.1
DDRV-080-*-H
Tamper-Resistant, Direct-Acting,
SOLENOID
Differential Area Relief Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DDRV - 080 - * - H - 30/ **** - **
DIRECTIONAL
DIFFERENTIAL PORTING
VALVES
AREA RELIEF VALVE 2N = 1/4 PTF
3N = 3/8 PTF
4T = SAE 4
CAVITY/SEAL 6T = SAE 6
Omit for Cartridge Only.
(Other porting
options available
ACCESSORIES
consult factory.)
SEALS
FACTORY PRESET PSI
N = Buna-N
50 PSI Increments (3.4 Bar)
V = Viton
example: 2550 = 2550 PSI (176 Bar)
(Omit for standard)
HIDDEN
TECHNICAL
5.07.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 146
DDRV-100
Adjustable, Direct-Acting,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
The DDRV-100 prevents flow from to until the set crack pressure
at is achieved. The poppet then unseats allowing flow from to
protecting the circuit from over pressurization.
RELIEF
SPECIFICATIONS
SHUTTLE
/ ISO
USASI Operating Pressure: 3600 PSI (248 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
Nominal Flow 20 GPM (75.7 L/min).
Internal Leakage: 20 drops/min. max. at reseat.
DIRECTIONAL
4000 (275.9)
Temperature: -30F to +250F (-35C to +120C)
Recommended Filtration: ISO 20/18/14
3000 (206.9)
150 ssu/32 cSt OIL @ 100F/38C Fluids: Mineral-based fluids. For other fluid compatibility, consult factory.
5000 (344.8)
Cavity/Cavity Tool: 100-2, see page 11.10.2
2000 (137.9)
In-Line Body Material: Anodized 6061T6 aluminum
PRESSURE DROP psi (bar)
4000 (275.9)
alloy rated at 3000 PSI (207 Bar).
TECHNICAL
1000 (69.0)
DATA
3000 (206.9)
0
0 5.0 10.0 15.0 20.0
2000 (137.9) (18.9) (37.9) (56.8) (75.7)
FLOW gpm (L/min.)
1000 (69.0)
10144-33 02/11
0
5.08.1 0 5.0 10.0 15.0 20.0
(18.9) (37.9) (56.8) (75.7)
FLOW gpm (L/min.)
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 147
DDRV-100
Adjustable, Direct-Acting,
SOLENOID
Differential Area Relief Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
HIDDEN ADJUSTMENT
.31 (7.9) HEX SOCKET
KNOB ADJUSTMENT
CONTROL
1.50 (38.1) DIA. KNOB
MOTION
SCREW ADJUSTMENT
.25 (6.4) HEX SOCKET
2.32
CONTROL
(58.9)
FLOW
5.19
3.19 (131.8)
(81.0) MAX.
MAX. 1.00 (25.4) HEX.
.75
RELIEF
TORQUE
30 FT.-LBS. (19.0)
(40.7 Nm) 1.50
MAX. (38.1) 2.00
(50.8)
PRESSURE
CONTROL
.28 TYP.
1.25 (7.1)
(31.8)
1.25
(31.8)
.13 1.63 .63
(3.3) (41.4) (16.0)
SEQUENCE
2.00 1.25
(50.8) (31.8)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DDRV - 100 - * - * - **/ **** - **
DIFFERENTIAL
DIRECTIONAL
PORTING
AREA RELIEF VALVE
VALVES
2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
8T = SAE 8
Omit for Cartridge Only.
CAVITY/SEAL (Other porting
options available
consult factory.)
ACCESSORIES
5.08.2
E1773dpor080ns spread:Deltrol2004Run8 3/6/11 9:07 PM Page 1
DPOR-080
Adjustable, Pilot-Operated
SOLENOID
Relief Valve
SERIES 8
CHECK
DESCRIPTION
An adjustable, pilot-operated spool cartridge valve designed to limit flow
CONTROL
in hydraulic circuits.
MOTION
OPERATION
CONTROL
FLOW
pressurization.
SPECIFICATIONS
DIRECTIONAL
VALVES
4000 (275.9)
Preset (See HOW TO ORDER)
PRESSURE DROP psi (bar)
3500 (241.4)
Temperature: -30F to +250F (-35C to +120C).
3000 (206.9) Recommended Filtration: ISO 17/15/13
2500 (172.4) Fluids: Mineral-based fluids.
2000 (137.9) For other fluid compatibility, consult factory
1500 (103.4) Cavity/Cavity Tool: 080-2, see page 11.08.2
1000 (69.0) In-Line Body Material: Anodized 6061T6 aluminum
TECHNICAL
0
0 5 10 15 20
(18.9) (37.9) (56.8) (75.7)
FLOW gpm (L/min.)
E1773 01/11
5.09.1
E1773dpor080ns spread:Deltrol2004Run8 3/6/11 9:07 PM Page 2
DPOR-080
Adjustable, Pilot-Operated
SOLENOID
Relief Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
SCREW ADJUSTMENT
3/16 (4.8) HEX. SOCKET
CONTROL
TORQUE
FLOW
20 FT.-LBS.
(27.1 Nm) MAX. 3.75 .59
1.75 (95.3) (15.0)
(44.5)
1.50
(38.1) 2.00
RELIEF
(50.8)
PRESSURE
(27.8) (7.1)
CONTROL
1.25 .56
(31.8) (14.2)
.13 1.63 1.13
(3.3) (41.4)
(28.7)
2.00
(50.8)
SEQUENCE
( ) Parentheses = Millimeters
SHUTTLE
HOW TO ORDER
DPOR - 080 - * - * - ** / **** - **
BODY PORTING
2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
Pilot Operated 6T = SAE 6
Relief Valve 8T = SAE 8
Omit for cartridge only.
Cavity/Seal (Other porting options available
consult factory.)
SPRING RANGE
ADJUSTMENT STYLE 20 = 300 to 2000 PSI (20 to 138 Bar)
S = SCREW Preset 1500 PSI (103 Bar)
TECHNICAL
5.09.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 148
DPOR-100
Adjustable, Pilot-Operated
SOLENOID
Relief Valve
SERIES 10
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
SPECIFICATIONS
Operating Pressure: 3000 PSI (207 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
DIRECTIONAL
3000 (206.9)
400 to 3000 PSI ( 28 to 207 Bar)
Preset: 2000 PSI (138 Bar)
2000 (137.9) 600 to 4000 PSI ( 41 to 276 Bar)
150 ssu/32 cSt OIL @ 100F/38C Preset: 3000 PSI (207 Bar)
4000 (275.9) Temperature: -30F to +250F (-35C to +120C).
1000 (69.0)
Recommended Filtration: ISO 20/18/14
TECHNICAL
3000 (206.9)
DATA
5.10.1
0
0 5.0 10.0 15.0 20.0 25.0 30.0
(18.9) (37.9) (56.8) (75.7) (94.6) (113.6)
FLOW gpm (L/min.)
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 149
DPOR-100
Adjustable, Pilot-Operated
SOLENOID
Relief Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
HIDDEN ADJUSTMENT
.31 (7.9) HEX SOCKET
SCREW ADJUSTMENT KNOB ADJUSTMENT
CONTROL
.25 (6.4) HEX SOCKET 1.50 (38.1) DIA.KNOB
MOTION
2.32
CONTROL
(58.9)
FLOW
5.19
3.19 (131.8)
(81.0) MAX.
MAX. 1.00 (25.4) HEX.
RELIEF
TORQUE .75
30 FT.-LBS. (19.0)
(40.7 Nm) 1.50
MAX. (38.1) 2.00
(50.8)
PRESSURE
CONTROL
.28 TYP .
1.25 (7.1)
(31.8)
1.25
(31.8)
.13 1.63 .63
(3.3) (41.4) (16.0)
SEQUENCE
2.00
(50.8) 1.25
(31.8)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DPOR - 100 - * - * - ** / **** - **
PORTING
PILOT-OPERATED
DIRECTIONAL
2N = 1/4 PTF
RELIEF VALVE
VALVES
3N = 3/8 PTF
6T = SAE 6
8T = SAE 8
CAVITY/SEAL Omit for Cartridge Only.
(Other porting
options available
consult factory.)
ACCESSORIES
SEALS
N = Buna N FACTORY PRESET PSI
V = Viton (Omit for standard)
SPRING RANGE
ADJUSTMENT STYLE 4 = 100 to 400 PSI ( 7 to 28 Bar)
H = Hidden Preset: 300 PSI ( 21 Bar)
K = Knob 20 = 300 to 2000 PSI ( 21 to 138 Bar)
TECHNICAL
5.10.2
E1718-RV-050 spread:Deltrol2004Run8 3/6/11 9:15 PM Page 1
RV-050
Relief Valve,
SOLENOID
Anti-Cavitation Check
SERIES 050
CHECK
DESCRIPTION
A cartridge valve designed to combine a shock relief valve, (direct acting)
CONTROL
OPERATION
CONTROL
FLOW
The RV-050 prevents flow from to until the set crack pressure at is
achieved. The poppet then unseats, allowing flow from to , protecting
the circuit from over pressurization.
RELIEF
FEATURES and BENEFITS
145 (10)
Crack Pressure Defined: Determined at .25 gpm (0.9 L/min)
Reseat Pressure: Nominal 80% of crack pressure
72.5 (5.0)
Temperature: -30F to +220F (-35C to +104C)
Recommended Filtration: ISO 20/18/14
0
0 2.6 5.3 8 10.6 13.3 16 Fluids: Mineral-based fluids.
(10) (20) (30) (40) (50) (60)
Cavity/Cavity Tool: R05-2, see page 11.25.2
ACCESSORIES
2900 (200)
TECHNICAL
1450 (100)
DATA
0
0 2.6 5.3 8 10.6 13.3 16
(10) (20) (30) (40) (50) (60)
FLOW gpm (L/min.)
E1718 01/11
5.12.1
E1718-RV-050 spread:Deltrol2004Run8 3/6/11 9:15 PM Page 2
RV-050
Relief Valve,
SOLENOID
Anti-Cavitation Check
SERIES 050
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.39 (10 mm) HEX. .86
(21.8)
TORQUE 25-30 Ft-Lbs.
(35-40 Nm)
CONTROL
FLOW
1.01
(25.7)
RELIEF
INSTALLATION
.28 (7.1) TYP.
.62
PRESSURE
CONTROL
1.25 (31.8) (15.9)
1.25
.25 (6.4) 2.00 (50.8) (31.8)
2.50 (63.5)
SEQUENCE
( ) Parentheses = Millimeters
SHUTTLE
HOW TO ORDER
RV - 050 - * - ** / *** - **
DIRECTIONAL
RELIEF VALVE PORTING
VALVES
4T = SAE 4
CAVITY 6T = SAE 6
Omit for Cartridge Only
SEALS
N = Buna N Factory Preset PSI (Omit for Standard)
V = Viton
ACCESSORIES
SPRING RANGE
10 = 500 to 1700 PSI (35 to 117 Bar)
Preset: 1000 PSI (69 Bar)
20 = 1700 to 3000 PSI (117 to 207 Bar)
Preset: 2500 PSI (172 Bar)
30 = 3000 to 3900 PSI (207 to 269 Bar)
Preset: 3500 PSI (241 Bar)
TECHNICAL
5.12.2
E1719-RV-060 spread:Deltrol2004Run8 3/6/11 9:15 PM Page 1
RV-060
Relief Valve,
SOLENOID
Anti-Cavitation Check
SERIES 060
CHECK
DESCRIPTION
A cartridge valve designed to combine a shock relief valve, (direct acting)
CONTROL
OPERATION
CONTROL
FLOW
The RV-060 prevents flow from to until the set crack pressure at is
achieved. The poppet then unseats allowing flow from to , protecting
the circuit from over pressurization.
RELIEF
145 (10) Crack Pressure Defined: Determined at .25 gpm (0.9 L/min)
Reseat Pressure: Nominal 80% of crack pressure
72.5 (5.0) Temperature: -30F to +220F (-35C to +104C)
Recommended Filtration: ISO 20/18/14
0 Fluids: Mineral-based fluids.
0 2.9 5.7 8.6 11.4 14.3 17.1 20
(11) (22) (33) (44) (55) (66) (77) Cavity/Cavity Tool: R06-2, see page 11.26.2
ACCESSORIES
FLOW gpm (L/min.) In-Line Body Material: Anodized 6061T6 aluminum alloy rated at
TO 3000 PSI (207 Bar).
150 ssu/32 cSt OIL @ 100F/38C
4350 (300)
PRESSURE DROP psi (bar)
2900 (200)
TECHNICAL
1450 (100)
DATA
0
0 2.9 5.7 8.6 11.4 14.3 17.1 20
(11) (22) (33) (44) (55) (66) (77)
FLOW gpm (L/min.)
E1719 01/11
5.12.3
E1719-RV-060 spread:Deltrol2004Run8 3/6/11 9:15 PM Page 2
RV-060
Relief Valve,
SOLENOID
Anti-Cavitation Check
SERIES 060
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.394 (10 mm) HEX. .98
TORQUE 25-30 Ft-Lbs. (25.0)
(35-40 Nm)
CONTROL
FLOW
1.01
(25.7)
RELIEF
INSTALLATION
.28 (7.14) TYP.
.62
(15.9)
PRESSURE
CONTROL
1.25 (31.7) 1.25
2.00 (50.8) (31.7)
.25 (6.4)
2.50 (63.5)
SEQUENCE
( ) Parentheses = Millimeters
SHUTTLE
HOW TO ORDER
RV - 060 - * - ** / *** - **
RELIEF VALVE
DIRECTIONAL
PORTING
VALVES
4T = SAE 4
CAVITY 6T = SAE 6
Omit for Cartridge Only
SEALS
N = Buna N Factory Preset PSI (Omit for Standard)
V = Viton
ACCESSORIES
SPRING RANGE
10 = 500 to 1700 PSI (35 to 117 Bar)
Preset: 1000 PSI (69 Bar)
20 = 1700 to 3000 PSI (117 to 207 Bar)
Preset: 2500 PSI (172 Bar)
30 = 3000 to 3900 PSI (207 to 269 Bar)
Preset: 3500 PSI (241 Bar)
40 = 4000 to 4200 PSI (276 to 290 Bar)
TECHNICAL
5.12.4
RV-080 spread:Deltrol2004Run8 3/6/11 9:16 PM Page 1
RV-080
Relief Valve,
SOLENOID
Anti-Cavitation Check
SERIES 080
CHECK
DESCRIPTION
A cartridge valve designed to combine a shock relief valve, (direct acting)
CONTROL
OPERATION
CONTROL
FLOW
The RV-080 prevents flow from to until the set crack pressure at is
achieved. The poppet then unseats allowing flow from to , protecting
the circuit from over pressurization.
RELIEF
FEATURES and BENEFITS
145 (10) Crack Pressure Defined: Determined at .25 gpm (0.9 L/min)
Reseat Pressure: Nominal 80% of crack pressure
72.5 (5.0) Temperature: -30F to +220F (-35C to +104C)
Recommended Filtration: ISO 20/18/14
0 Fluids: Mineral-based fluids.
0 3.4 6.8 10.2 13.6 17.0 20.4 23.8
(13) (26) (39) (52) (65) (78) (91) Cavity/Cavity Tool: R08-2, see page 11.28.2
ACCESSORIES
FLOW gpm (L/min.) In-Line Body Material: Anodized 6061T6 aluminum alloy rated at
TO 3000 PSI (207 Bar).
150 ssu/32 cSt OIL @ 100F/38C
4350 (300)
PRESSURE DROP psi (bar)
2900 (200)
TECHNICAL
1450 (100)
DATA
0
0 3.4 6.8 10.2 13.6 17.0 20.4 23.8
(13) (26) (39) (52) (65) (78) (91)
FLOW gpm (L/min.)
01/11
5.12.5
RV-080 spread:Deltrol2004Run8 3/6/11 9:16 PM Page 2
RV-080
Relief Valve,
SOLENOID
Anti-Cavitation Check
SERIES 080
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.39 (10mm) HEX. 1.09
TORQUE 25-30 Ft-Lbs. (27.8)
(35-40 Nm)
CONTROL
FLOW
1.01
(25.7)
RELIEF
(55.1)
INSTALLATION
PRESSURE
(15.9)
CONTROL
1.25 (31.7)
1.25
.250 (6.35) 2.000 (50.80) (31.7)
2.500 (63.50)
SEQUENCE
( ) Parentheses = Millimeters
SHUTTLE
HOW TO ORDER
RV - 080 - * - ** / *** - **
RELIEF VALVE
DIRECTIONAL
PORTING
VALVES
4T = SAE 4
CAVITY 6T = SAE 6
Omit for Cartridge Only
SEALS
N = Buna N Factory Preset PSI (Omit for Standard)
V = Viton
ACCESSORIES
SPRING RANGE
10 = 500 to 1700 PSI (35 to 117 Bar)
Preset: 1000 PSI (69 Bar)
20 = 1700 to 3000 PSI (117 to 207 Bar)
Preset: 2500 PSI (172 Bar)
30 = 3000 to 3900 PSI (207 to 269 Bar)
Preset: 3500 PSI (241 Bar)
40 = 4000 to 4200 PSI (276 to 290 Bar)
TECHNICAL
5.12.6
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 150
DBRV-100
Adjustable, Bi-Directional
SOLENOID
Relief Valve
SERIES 10
CHECK
DESCRIPTION
An adjustable, bi-directional poppet type cartridge valve designed to
CONTROL
OPERATION
CONTROL
FLOW
over pressurization.
SPECIFICATIONS
Operating Pressure: 3600 PSI (248 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
DIRECTIONAL
10144-16 02/11
5.13.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 151
DBRV-100
Adjustable, Bi-Directional
SOLENOID
Relief Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DBRV - 100 - * - * - ** / **** - **
BI-DIRECTIONAL
DIRECTIONAL
PORTING
RELIEF VALVE
VALVES
2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
CAVITY/SEAL 8T = SAE 8
Omit for Cartridge Only.
(Other porting
options available
ACCESSORIES
consult factory.)
SEALS
N = Buna N
V = Viton FACTORY PRESET PSI
(Omit for standard)
5.13.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 152
DBRVS-100-*-H
Tamper-Resistant, Direct-Acting,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
An adjustable, bi-directional poppet type cartridge valve designed to
CONTROL
OPERATION
CONTROL
FLOW
over pressurization.
SPECIFICATIONS
SHUTTLE
Operating Pressure: 5000 PSI (345 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
Nominal Flow 20 GPM (75.7 L/min).
Internal Leakage: 5 in.3/min. (82cc/min.) max. at reseat.
DIRECTIONAL
10171-61 02/11
5.14.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 153
DBRVS-100-*-H
Tamper-Resistant, Direct,
SOLENOID
Bi-Directional Relief Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
3.70
1.00 (25.4) HEX
FLOW
(94.0) .75
TORQUE
1.70 30 FT.-LBS. (19.0)
(43.2) 1.50
(40.7 Nm) 2.00
(38.1)
MAX. (50.8)
RELIEF
.28 TYP.
1.25 (7.1)
(31.8)
1.25
(31.8)
1.63 .63
PRESSURE
.13
CONTROL
(41.4) (16.0)
(3.3)
2.00 1.25
(50.8) (31.8)
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DBRVS - 100 - * - H - 50 / **** - **
BI-DIRECTIONAL
DIRECTIONAL
RELIEF VALVE (SHORT) PORTING
VALVES
2N = 1/4 PTF
3N = 3/8 PTF
CAVITY/SEAL 6T = SAE 6
8T = SAE 8
Omit for Cartridge Only.
(Other porting options
SEALS
available-consult factory.)
ACCESSORIES
N = Buna N
V = Viton
FACTORY PRESET PSI
(Omit for standard)
SPRING RANGE
DATA
5.14.2
E1773drvk080ns spread:Deltrol2004Run8 3/6/11 9:13 PM Page 1
DRVK-080
Adjustable, Pilot-Operated,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
An adjustable, pilot-operated spool cartridge valve designed to allow flow
CONTROL
OPERATION
CONTROL
FLOW
Quiet operation.
SEQUENCE
UNLOADED
150 ssu/32 cSt OIL @ 100F/38C
SPECIFICATIONS
PRESSURE DROP psi (bar)
VALVES
200 (13.8)
150 (10.3)
450 (31.0)
400 (27.6) Temperature: -30F to +250F (-35C to +120C).
350 (24.1)
300 (20.7)
Recommended Filtration: ISO 17/15/13
250 (17.2) Fluids: Mineral-based fluids.
200 (13.8)
TECHNICAL
100 (6.9)
50 (3.4)
Cavity/Cavity Tool: 080-2, see page 11.08.2
0
0 5 10 15 20
In-Line Body Material: Anodized 6061T6 aluminum
(18.9) (37.9) (56.8) (75.7) alloy rated at 3000 PSI (207 Bar).
FLOW gpm (L/min.)
E1773 01/11
5.20.1
E1773drvk080ns spread:Deltrol2004Run8 3/6/11 9:13 PM Page 2
DRVK-080
Adjustable, Pilot-Operated,
SOLENOID
Kick-Down Relief Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
SCREW ADJUSTMENT
3/16 (4.8) HEX. SOCKET
CONTROL
.88 (22.4) HEX
FLOW
TORQUE
20 FT-LBS
(27.1 Nm) MAX. 3.75 .59
1.75 (95.3) (15.0)
(44.5)
1.50
(38.1) 2.00
RELIEF
(50.8)
PRESSURE
CONTROL
1.25 .56
(31.8) (14.2)
.13 1.63 1.13
(41.4) (28.7)
(3.3)
2.00
(50.8)
SEQUENCE
( ) Parentheses = Millimeters
SHUTTLE
HOW TO ORDER
DRVK - 080 - * - * - ** / **** - **
BODY PORTING
2N = 1/4 PTF
DIRECTIONAL
3N = 3/8 PTF
VALVES
Kick-Down 6T = SAE 6
Relief Valve 8T = SAE 8
Omit for cartridge only.
Cavity/Seal (Other porting options available
consult factory.)
SPRING RANGE
ADJUSTMENT STYLE 20 = 300-2000 PSI (20 to 138 Bar)
S = SCREW Preset 1500 PSI (103 Bar)
TECHNICAL
5.20.2
E1788-ZTRV-62-U-XX spread:Deltrol2004Run8 3/6/11 9:19 PM Page 1
ZTRV-62
Thermal,
SOLENOID
Relief Valve
ZERO PROFILE
CHECK
DESCRIPTION
A directing poppet cartridge thermal relief valve designed to limit
CONTROL
intensification.
OPERATION
CONTROL
FLOW
The ZTRV-62 prevents flow from to until the set crack pressure at
is achieved. The poppet then unseats, allowing flow from to , limiting
system pressure.
RELIEF
SPECIFICATIONS
E1788 01/11
5.30.1
E1788-ZTRV-62-U-XX spread:Deltrol2004Run8 3/6/11 9:19 PM Page 2
ZTRV-62
Thermal,
SOLENOID
Relief Valve
ZERO PROFILE
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
9/16-18 THREAD
UTILIZING .062 (1.6) WIDE SLOTS TORQUE 10 FT-LBS
(13.6 Nm) MAX.
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
TAMPER RESISTANT END PLATE
.84
WITH PRESSURE SETTING (21.4)
SEQUENCE
( ) Parentheses = Millimeters
SHUTTLE
HOW TO ORDER
ZTRV - 62 - U - ****
DIRECTIONAL
VALVES
THERMAL RELIEF SET PRESSURE 2000 PSI (138 Bar)
VALVE RANGE 2000 to 5000 PSI (138 to 345 Bar)
CAVITY
ACCESSORIES
SEALS
U = Urethane
TECHNICAL
DATA
5.30.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 154
DPR-100
Adjustable, Direct-Acting,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
The DPR-100 in the steady state will allow bi-directional flow between
and with spring chamber vented. When the preset pressure
at is achieved, the spool throttles to regulate pressure at by
restricting flow at .
RELIEF
SPECIFICATIONS
SHUTTLE
3000 (206.9)
Fluids: Mineral-based fluids. For other fluid compatibility, consult factory.
PRESSURE Drop psi (bar)
1000 (69.0)
500 (34.5)
TECHNICAL
0
DATA
PORT TO PORT TO
FLOW gpm (L/min.)
10129-56 02/11
6.02.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 155
DPR-100
Adjustable, Direct-Acting,
SOLENOID
Pressure Reducing/Relieving Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
SCREW ADJUSTMENT 1.50 (38.1) DIA. KNOB .31 (7.9) HEX SOCKET
MOTION
.25 (6.4) HEX SOCKET
2.32
CONTROL
(58.9)
FLOW
5.82
3.19 (147.8)
(81.0) MAX.
MAX.
.75
1.00 (25.4) HEX. (19.1)
RELIEF
TORQUE 1.38
30 FT.-LBS. (35.1)
(40.7 Nm) MAX. 2.13
(54.1)
2.63
(66.8)
PRESSURE
CONTROL
1.82
(46.2) .28 TYP.
(7.1)
1.25 .63
(31.8) (16.0)
.25 2.00 1.25
(6.4) (50.8) (31.8)
2.50
SEQUENCE
(63.5)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DPR - 100 - * - * - ** / **** - **
DIRECTIONAL
PRESSURE REDUCING
VALVE PORTING
VALVES
2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
CAVITY/SEAL 8T = SAE 8
Omit for Cartridge Only.
(Other porting options available
consult factory.)
ACCESSORIES
SEALS
N = Buna N FACTORY PRESET PSI
V = Viton (Omit for standard)
6.02.2
E1834-DPRR-080-N-S spread:Deltrol2004Run8 3/6/11 9:08 PM Page 1
DPRR-080
Adjustable, Pilot-Operated,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
SPECIFICATIONS
1
Operating Pressure: 5000 PSI (345 Bar)
DIRECTIONAL
4000 (275.9)
In-Line Body Material: Anodized 6061T6 aluminum
3000 (206.9) allow rated at 3000 PSI (207 Bar).
2000 (137.9)
TECHNICAL
1000 (69.0)
DATA
0
0 6.0 4.0 2.0 2.0 4.0 6.0
(22.7) (15.1) (7.6) (7.6) (15.1) (22.7)
E1834 01/11
6.03.1
E1834-DPRR-080-N-S spread:Deltrol2004Run8 3/6/11 9:08 PM Page 2
DPRR-080
Adjustable, Pilot-Operated,
SOLENOID
Pressure Reducing/Relieving Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
SCREW ADJUSTMENT HIDDEN ADJUSTMENT
3/16 (4.8) HEX SOCKET
CONTROL
TORQUE
FLOW
20 FT.-LBS. .61 4.38
(27.1 Nm) MAX. (15.5) (111.1)
1.75 1.17
(29.7)
(44.5) 1.25
2.13
(31.8)
(54.1)
2.63
(66.8)
RELIEF
1.652
(42.0)
.28 TYP.
(7.1)
PRESSURE
CONTROL
1.25 .56
(31.8) (14.2)
.25 2.00 1.13
(6.4) (50.8)
2.50
(28.7)
(63.5)
SEQUENCE
( ) Parentheses = Millimeters
SHUTTLE
HOW TO ORDER
DIRECTIONAL
REDUCING/RELIEVING
VALVE 2N = 1/4 PTF
VALVES
3N = 3/8 PTF
CAVITY/SEAL 6T = SAE 6
8T = SAE 8
Omit for cartridge only.
(Other porting options
SEALS
available consult factory.)
N = Buna N
V = Viton
ACCESSORIES
ADJUSTMENT STYLE
S = SCREW SPRING RANGE
H = HIDDEN (TAMPER RESISTANT) 20 = 300 to 2000 PSI (20 to 138 Bar)
TECHNICAL
6.03.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 156
DDPS-100-3NCS
Differential Pressure
SOLENOID
Sensing Valve
SERIES 10
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
SPECIFICATIONS
10148-33 02/11
6.11.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 157
DDPS-100-3NCS
Differential Pressure
SOLENOID
Sensing Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DDPS - 100 - 3 NC S - * - *** - **
DIRECTIONAL
DIFFERENTIAL
PORTING
VALVES
PRESSURE
SENSING VALVE 2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
CAVITY/SEAL 8T = SAE 8
Omit for Cartridge Only.
(Other porting options available
consult factory.)
ACCESSORIES
FLOW PATH
N = Buna N
V = Viton
6.11.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 158
DDPS-160
Differential Pressure
SOLENOID
Sensing Valve
SERIES 16
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
SPECIFICATIONS
SHUTTLE
250 (17.2)
200 (13.8)
150 (10.3)
100 (6.9)
TECHNICAL
DATA
50 (3.4)
0
0 10 20 30 40 50
(37.9) (75.7) (113.6) (151.4) (189.3)
FLOW gpm (L/min.)
10133-33 02/11
6.13.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 159
DDPS-160
Differential Pressure
SOLENOID
Sensing Valve
SERIES 16
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
1.50 (38.1) HEX
1.06
CONTROL
TORQUE 90 FT.-LBS.
(26.9)
FLOW
(122.0 Nm) MAX.
RELIEF
2.19
(55.6)
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DDPS - 160 - * - ***
DIFFERENTIAL
DIRECTIONAL
PRESSURE
VALVES
SENSING VALVE
DIFFERENTIAL
PRESSURE SETTING
CAVITY/SEAL 5 = 5 PSI ( 0.3 Bar)
20 = 20 PSI ( 1.4 Bar)
ACCESSORIES
6.13.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 160
DPS-100
Adjustable, Direct-Acting
SOLENOID
SERIES 10
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
The DPS-100 in the steady state blocks flow at and with spring
chamber drained. When the preset pressure at is achieved, the
spool shifts to allow flow from to .
RELIEF
Compact size.
SPECIFICATIONS
SHUTTLE
25 (1.7)
In-Line Body Material: Anodized 6061T6 aluminum
20 (1.4)
alloy rated at 3000 PSI (207 Bar).
15 (1.0)
10 (.7)
TECHNICAL
5 (.3)
DATA
0
0 1.0 2.0 3.0 4.0 5.0 6.0
(3.8) (7.6) (11.4) (15.1) (18.9) (22.7)
10129-29 02/11
7.02.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 161
DPS-100
Adjustable, Direct-Acting
SOLENOID
Externally-Drained Sequence Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
SCREW ADJUSTMENT
MOTION
.25 (6.4) HEX SOCKET
2.32
CONTROL
(58.9)
FLOW
5.82
3.19 (147.8)
(81.0) MAX.
MAX.
.75
1.00 (25.4) HEX. (19.0)
RELIEF
TORQUE 1.38
30 FT.- LBS. (35.1)
(40.7 Nm) MAX. 2.13 2.63
(54.1)
(66.8)
PRESSURE
CONTROL
1.82
(46.2) .28 TYP.
(7.1)
1.25 .63
(31.8) (16.0)
2.00 1.25
.25 (50.8) (31.8)
SEQUENCE
(6.4) 2.50
(63.5)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DPS - 100 - * - * - ** / **** - **
PRESSURE
DIRECTIONAL
PORTING
SEQUENCE VALVE
VALVES
2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
8T = SAE 8
CAVITY/SEAL Omit for Cartridge Only.
(Other porting
options available
consult factory.)
ACCESSORIES
SEALS
N = Buna N FACTORY PRESET PSI
V = Viton (Omit for standard)
SPRING RANGE
ADJUSTMENT STYLE 2 = 50 to 200 PSI ( 3 to 14 Bar)
TECHNICAL
7.02.2
E1814 DPS2-080-N-S spread:Deltrol2004Run8 3/6/11 9:08 PM Page 1
DPS2-080
Adjustable, Internally-Piloted,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
SPECIFICATIONS
SEQUENCE
TO
150 ssu/32 cSt OIL @ 100F/38C
200 (13.6)
PRESSURE DROP psi (bar)
150 (10.2)
100 (6.8)
50 (3.4)
TECHNICAL
DATA
0
0 1.0 2.0 3.0 4.0 5.0 6.0
(3.8) (7.6) (11.4) (15.2) (19.0) (23)
FLOW gpm (L/min.)
E1814 01/11
7.03.1
E1814 DPS2-080-N-S spread:Deltrol2004Run8 3/6/11 9:08 PM Page 2
DPS2-080
Adjustable, Internally-Piloted,
SOLENOID
Internally-Drained Sequence Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
2.91 .88 (22.4) HEX.
FLOW
(73.9) TORQUE
20 FT.-LBS.
(27.1 Nm) MAX.
.61 (15.5)
1.17
RELIEF
(29.7)
5.54
2.13 (140.7)
(54.1)
2.63
(66.8)
PRESSURE
CONTROL
1.69
(42.9)
.28 (7.1)
TYP
.25 1.25
(31.7) .56
(6.3)
(14.2)
2.00 (50.8)
2.50 (63.5) 1.13
SEQUENCE
(28.7)
( ) Parentheses = Millimeters
SHUTTLE
HOW TO ORDER
DIRECTIONAL
PRESSURE
VALVES
PORTING
SEQUENCE VALVE 2N = 1/4 PTF
3N = 3/8 PTF
CAVITY/SEAL 4T = SAE 4
6T = SAE 6
Omit for Cartridge Only.
SEALS (Other porting options available
ACCESSORIES
SPRING RANGE
DATA
4 = 50 to 400 PSI
20 = 300 to 2000 PSI
30 = 1500 to 4000 PSI
7.03.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 162
DPS2-100
Adjustable, Internally-Piloted,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
Compact size.
SPECIFICATIONS
SHUTTLE
125 (8.6)
100 (6.9)
75 (5.2)
50 (3.4)
TECHNICAL
25 (1.7)
DATA
0
0 1.0 2.0 3.0 4.0 5.0
(3.8) (7.6) (11.4) (15.1) (18.9)
10138-03 02/11
7.04.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 163
DPS2-100
Adjustable, Internally-Piloted,
SOLENOID
Internally-Drained Sequence Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
SCREW ADJUSTMENT 1.50 (38.1) DIA. KNOB .31 (7.9) HEX SOCKET
MOTION
.25 (6.4) HEX SOCKET
2.32
CONTROL
(58.9)
FLOW
5.82
3.19 (147.8)
(81.0) MAX.
MAX.
.75
1.00 (25.4) HEX.
RELIEF
(19.0) 1.38
TORQUE
30 FT.- LBS. (35.1)
2.13
(40.7 Nm) MAX. (54.1) 2.63
(66.8)
PRESSURE
CONTROL
1.82
(46.2) .28 TYP.
(7.1)
1.25 .63
(31.8) (16.0)
.25 2.00 1.25
(50.8)
SEQUENCE
(6.4) (31.8)
2.50
(63.5)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DPS2 - 100 - * - * - 24 / **** - **
PRESSURE
DIRECTIONAL
PORTING
SEQUENCE VALVE
VALVES
2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
8T = SAE 8
CAVITY/SEAL Omit for Cartridge Only.
(Other porting
options available
consult factory.)
ACCESSORIES
SEALS
N = Buna N
V = Viton
FACTORY PRESET PSI
(Omit for standard)
ADJUSTMENT STYLE
TECHNICAL
H =- Hidden
DATA
K = Knob
SPRING RANGE
S = Screw
24 = 400 to 2400 PSI (28 to 166 Bar)
Preset: 2000 PSI (138 Bar)
7.04.2
E1855-DPS3-080-U-S spread:Deltrol2004Run8 3/6/11 9:09 PM Page 1
DPS3-080
Adjustable, Pilot-Operated,
SOLENOID
Sequence Valve
SERIES 8
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
The DPS3-080 in steady state blocks flow at while allowing flow from
to . When the preset pressure at is achieved the pilot section
opens. This pilot flow creates a pressure differential across the spool,
which causes the spool to shift to allow flow from to .
RELIEF
1
FEATURES and BENEFITS
PRESSURE
CONTROL
SPECIFICATIONS
Operating Pressure: 5000 PSI (345 Bar)
Flow: 6 GPM (22.7 L/min.)
Internal Leakage: 5 in3/min. (82 cc/min.) max. at 3000 PSI (207 Bar)
DIRECTIONAL
125 (8.6)
100 (6.9)
75 (5.2)
50 (3.4)
TECHNICAL
25 (1.7)
DATA
0
0 1.0 2.0 3.0 4.0 5.0 6.0
(3.8) (7.6) (11.4) (15.1) (18.9) (22.7)
E1855 02/11
7.04.3
E1855-DPS3-080-U-S spread:Deltrol2004Run8 3/6/11 9:09 PM Page 2
DPS3-080
Adjustable, Pilot-Operated,
SOLENOID
Sequence Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
SCREW ADJUSTMENT HIDDEN ADJUSTMENT
3/16 (4.8) HEX SOCKET
CONTROL
TORQUE
FLOW
20 FT.-LBS.
.61 4.38
(27.1 Nm) MAX. (15.5) (111.1)
1.75 1.17
(44.5) (29.7)
1.25
(31.8) 2.13
(54.1) 2.63
RELIEF
(66.8)
1.652
(42.0)
.28 TYP.
PRESSURE
(7.1)
CONTROL
1.25 .56
(31.8) (14.2)
.25 2.00 1.13
(6.4) (50.8) (28.7)
2.50
(63.5)
SEQUENCE
( ) Parentheses = Millimeters
SHUTTLE
HOW TO ORDER
DIRECTIONAL
PRESSURE PORTING
VALVES
SEQUENCE VALVE 2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
CAVITY/SEAL 8T = SAE 8
Omit for cartridge only.
(Other porting options
available consult factory.)
ACCESSORIES
SEALS
U = Urethane
Other options available - FACTORY PRESET PSI
Consult factory
50 PSI Increments
(Omit for Std.)
ADJUSTMENT STYLE
S = Screw
TECHNICAL
SPRING RANGE
H = Hidden (Tamper Resistant)
DATA
7.04.4
E1834-DPSK-080-N-S spread:Deltrol2004Run8 3/6/11 11:50 PM Page 1
DPSK-080
Adjustable, Pilot-Operated,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
An adjustable, pilot-operated spool cartridge valve designed to direct oil
CONTROL
OPERATION
CONTROL
FLOW
The DPSK-080 in steady state blocks flow at while allowing flow from
to . When the preset pressure at is achieved, the pilot section
opens. This pilot flow creates a pressure differential across the spool,
which causes the spool to shift to allow flow from to .
RELIEF
The spool will not shift back (kick-down) until pressure at falls below a
predetermined pressure.
PRESSURE
CONTROL
SPECIFICATIONS
DIRECTIONAL
125 (8.6)
Recommended Filtration: ISO 19/15
100 (6.9) Fluids: Mineral-based fluids.
75 (5.2)
For other fluid compatibility, consult factory.
Cavity/Cavity Tool: 080-3, see page 11.08.3
50 (3.4)
In-Line Body Material: Anodized 6061T6 aluminum alloy rated at
25 (1.7) 3000 psi (207 Bar).
TECHNICAL
0
DATA
E1834 01/11
7.04.7
E1834-DPSK-080-N-S spread:Deltrol2004Run8 3/6/11 11:50 PM Page 2
DPSK-080
Adjustable, Pilot-Operated,
SOLENOID
Kick-Down Sequence Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
SCREW ADJUSTMENT HIDDEN ADJUSTMENT
3/16 (4.8) HEX SOCKET
CONTROL
TORQUE
FLOW
20 FT.-LBS.
(27.1 Nm) MAX. .61 4.38
1.75 (15.5) (111.1)
1.17
(44.5) 1.25 (29.7)
(31.8)
2.13
(54.1)
RELIEF
2.63
(66.8)
1.652
(42.0)
PRESSURE
.28 TYP.
CONTROL
(7.1)
1.25 .56
(31.8) (14.2)
2.00 1.13
.25
(6.4)
(50.8) (28.7)
2.50
(63.5)
SEQUENCE
( ) Parentheses = Millimeters
SHUTTLE
HOW TO ORDER
DIRECTIONAL
KICK-DOWN
SEQUENCE VALVE 2N = 1/4 PTF
VALVES
3N = 3/8 PTF
CAVITY/SEAL 6T = SAE 6
8T = SAE 8
Omit for cartridge only.
(Other porting options
SEALS
available consult factory.)
N = Buna N
V = Viton
ACCESSORIES
ADJUSTMENT STYLE
S = SCREW SPRING RANGE
H = HIDDEN (TAMPER RESISTANT) 20 = 300 to 2000 PSI (20 to 138 Bar)
TECHNICAL
7.04.8
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 164
DPSK-100 (Reset
120 PSI)
Adjustable, Pilot-Operated
SOLENOID
SERIES 10
CHECK
DESCRIPTION
An adjustable, pilot-operated spool cartridge valve designed to direct
CONTROL
OPERATION
CONTROL
FLOW
The spool will not shift back (kick-down) until pressure at falls below
a predetermined pressure.
PRESSURE
CONTROL
SPECIFICATIONS
Operating Pressure: 3000 PSI (207 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
DIRECTIONAL
Internal Leakage: 5 in.3/min. (82 cc/min.) max. at 3000 PSI (207 Bar)
VALVES
10145-84 02/11
7.05.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 165
DPSK-100 (Reset
120 PSI)
Adjustable, Pilot-Operated
SOLENOID
Kick-Down Sequence Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DPSK - 100 - * - * - ** / **** - **
DIRECTIONAL
KICK-DOWN PRESSURE PORTING
VALVES
SEQUENCE VALVE 2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
8T = SAE 8
CAVITY/SEAL Omit for Cartridge Only.
(Other porting options available
consult factory.)
ACCESSORIES
SEALS
N = Buna N FACTORY PRESET PSI
V = Viton (Omit for standard)
SPRING RANGE
ADJUSTMENT STYLE 5 = 300 to 500 PSI ( 21 to 34 Bar)
TECHNICAL
7.05.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 166
DPSK2-100 (Reset
300 PSI)
Adjustable, Pilot-Operated
SOLENOID
SERIES 10
CHECK
DESCRIPTION
An adjustable, pilot-operated spool cartridge valve designed to direct oil
CONTROL
OPERATION
CONTROL
FLOW
spool will not shift back (kick-down) until pressure at falls below a
predetermined pressure.
PRESSURE
CONTROL
SPECIFICATIONS
Internal Leakage: 5 in.3/min. (82 cc/min.) max. at 3000 PSI (207 Bar)
Spring Ranges: 350 to 3000 PSI ( 24 to 207 Bar)
PRESSURE DROP VS. FLOW Preset: 1200 PSI ( 83 Bar)
Reset Spring Pressure: 300 PSI (21 Bar)
Temperature: -30F to +250F (-35C to +120C)
Recommended Filtration: ISO 20/18/14
ACCESSORIES
10156-90 02/11
7.06.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 167
DPSK2-100 (Reset
300 PSI)
Adjustable, Pilot-Operated
SOLENOID
Kick-Down Sequence Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DPSK2 - 100 - * - * - ** / **** - **
KICK-DOWN PRESSURE
DIRECTIONAL
PORTING
SEQUENCE VALVE
VALVES
2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
8T = SAE 8
CAVITY/SEAL Omit for Cartridge Only.
(Other porting
options available
consult factory.)
ACCESSORIES
SEALS
N = Buna N FACTORY PRESET PSI
V = Viton (Omit for standard)
SPRING RANGE
ADJUSTMENT STYLE 30 = 350 to 3000 PSI (24 to 207 Bar)
TECHNICAL
K = Knob
S = Screw
7.06.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 168
ZSHB-63
Ball-Type
SOLENOID
Shuttle Valve
ZERO PROFILE
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
The ZSHB-63 allows the check ball to move away from inlet
port or with the greatest differential pressure and seat against
the other inlet port having the least differential pressure. This provides
a flow path to outlet port .
RELIEF
SPECIFICATIONS
10206-10 02/11
8.02.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 169
ZSHB-63
Ball-Type
SOLENOID
Shuttle Valve
ZERO PROFILE
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
ZSHB - 63 - U - **
DIRECTIONAL
SHUTTLE VALVE
VALVES
CAVITY PORTING
4T = SAE 4
Omit for Cartridge Only.
SEALS
U = Urethane
ACCESSORIES
TECHNICAL
DATA
8.02.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 170
ZSH2-63
Zero Leak, Spring-Bias
SOLENOID
Shuttle Valve
ZERO PROFILE
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
The ZSH2-63 allows the spring-bias poppet to move away from inlet
port (biased closed) or with the greatest differential pressure and seat
against the other inlet port having the least differential pressure. This
provides a flow path to outlet port .
RELIEF
SPECIFICATIONS
PRESSURE DROP VS. FLOW Cavity/Cavity Tool: ZP63, see page 11.06.3
VALVES
10234-55 02/11
8.03.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 171
ZSH2-63
Zero Leak, Spring-Bias
SOLENOID
Shuttle Valve
ZERO PROFILE
CHECK
INSTALLATION DIMENSIONS
#6 SAE PLUG
CONTROL
MOTION
.60
.25 (6.4) HEX. SOCKET (15.3)
9/16-18 THREAD
TORQUE 10 FT.-LBS 1.50
(13.6 Nm) MAX
CONTROL
(38.1)
FLOW
2.75 2.86
(69.9) (72.6)
RELIEF
1.44
(36.5)
.50
PRESSURE
.28 TYP.
CONTROL
(12.8)
(7.1)
1.00
.50
.25 (12.7)
(6.4) (25.4)
1.50
(38.1) 1.00
(25.4)
SEQUENCE
2.00
(50.8)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
ZSH 2 - 63 - U - **
DIRECTIONAL
SHUTTLE VALVE
VALVES
SPRING-BIASED PORTING
4T = SAE 4
6T = SAE 6
Omit for Cartridge Only.
CAVITY
ACCESSORIES
SEALS
U = Urethane
TECHNICAL
DATA
8.03.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 172
DSH-100
Ball-Type
SOLENOID
Shuttle Valve
SERIES 10
CHECK
DESCRIPTION
A cartridge valve designed to direct flow from either of the two
CONTROL
OPERATION
CONTROL
FLOW
The DSH-100 allows the check ball to move away from inlet
port or with the greatest differential pressure and seat against
the other inlet port having the least differential pressure providing a
flow path to outlet port .
RELIEF
SPECIFICATIONS
Operating Pressure: 3000 PSI (207 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
Internal Leakage: 5 drops/min. max. at 3000 PSI (207 Bar)
SHUTTLE
150 ssu/32 cSt OIL @ 100F/38C
100 (6.9)
PRESSURE DROP psi (bar)
80 (5.5)
60 (4.1)
40 (2.8)
TECHNICAL
20 (1.4)
DATA
0
0 1.0 2.0 3.0 4.0 5.0 6.0
(3.8) (7.6) (11.4) (15.1) (18.9) (22.7)
FLOW gpm (L/min.)
10128-38 02/11
8.05.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 173
DSH-100
Ball-Type
SOLENOID
Shuttle Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
.38
(9.7)
1.00 (25.4) HEX. .75
TORQUE 30 FT.-LBS. (19.0)
CONTROL
(40.7 Nm) MAX. 1.38
FLOW
(35.1)
2.13
(54.1) 2.63
(66.8)
1.82
(46.2) 3.01
RELIEF
(76.5)
.28 TYP.
(7.1)
PRESSURE
CONTROL
1.25 .63
(31.8) (16.0)
.25 2.00 1.25
(6.4) (50.8) (31.8)
2.50
(63.5)
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DSH - 100 - * - **
DIRECTIONAL
SHUTTLE VALVE
VALVES
CAVITY/SEAL PORTING
2N = 1/4 PTF
3N = 3/8 PTF
SEALS 6T = SAE 6
N = Buna N 8T = SAE 8
ACCESSORIES
8.05.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 174
DMP-080-2NCP
Manual Pull, Two-Way,
SOLENOID
SERIES 8
CHECK
DESCRIPTION
A manual operated pull style cartridge valve designed with positive
CONTROL
OPERATION
CONTROL
FLOW
SPECIFICATIONS
TO OR TO
150 ssu/32 cSt OIL @ 100F/38C
200 (13.8)
ACCESSORIES
160 (11.0)
120 (8.3)
80 (5.5)
40 (2.8)
TECHNICAL
DATA
0
0 2.0 4.0 6.0 8.0 10.0
(7.6) (15.1) (22.7) (30.3) (37.9)
FLOW gpm (L/min.)
10183-46(B) 02/11
9.01.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 175
DMP-080-2NCP
Manual Pull, Two-Way,
SOLENOID
Normally Closed Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
1.50 DIA.
CONTROL
(38.2)
MOTION
.88 (22.4) HEX.
TORQUE 20 FT.-LBS.
(27.1 Nm) MAX.
CONTROL
FLOW
3.88
1.88 (98.6) .59
(47.6) (15.0)
1.50
(38.1) 2.00
RELIEF
(50.8)
.28 TYP.
(7.1)
PRESSURE
CONTROL
1.06 1.25 .56
(26.9) (31.8) (14.2)
.13 1.63 1.13
(3.3) (41.4) (28.7)
2.00
(50.8)
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DMP - 080 - 2 NC P - * - **
DIRECTIONAL
MANUAL PULL
VALVES
PORTING
2N = 1/4 PTF
3N = 3/8 PTF
4T = SAE 4
CAVITY/SEAL 6T = SAE 6
Omit for Cartridge Only.
ACCESSORIES
POPPET
TECHNICAL
NORMALLY CLOSED
DATA
9.01.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 176
DTV-080
Normally Closed, Detent,
SOLENOID
Toggle-Operated Valve
SERIES 8
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
SPECIFICATIONS
Operating Pressure: 3000 PSI (207 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
Internal Leakage: 5 drops/min. max. at 3000 PSI (207 Bar)
DIRECTIONAL
10133-81 02/11
9.03.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 177
DTV-080
Normally Closed, Detent,
SOLENOID
Toggle-Operated Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DTV - 080 - * - **
DIRECTIONAL
TOGGLE VALVE
VALVES
PORTING
2N = 1/4 PTF
3N = 3/8 PTF
CAVITY/SEAL 4T = SAE 4
6T = SAE 6
ACCESSORIES
SEALS
N = Buna N
V = Viton
TECHNICAL
DATA
9.03.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 178
DTV2-080
Normally Closed,
SOLENOID
Toggle-Operated Valve
SERIES 8
CHECK
DESCRIPTION
A toggle-operated cartridge valve designed with positive shut off to be
CONTROL
OPERATION
CONTROL
FLOW
SPECIFICATIONS
SHUTTLE
160 (11.0)
120 (8.3)
80 (5.5)
40 (2.8)
TECHNICAL
DATA
0
0 2.0 4.0 6.0 8.0 10.0
(7.6) (15.1) (22.7) (30.3) (37.9)
10179-07 02/11
9.04.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 179
DTV2-080
Normally Closed,
SOLENOID
Toggle-Operated Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DTV2 - 080 - * - **
DIRECTIONAL
PORTING
VALVES
2N = 1/4 PTF
3N = 3/8 PTF
4T = SAE 4
TOGGLE VALVE 6T = SAE 6
Omit for Cartridge Only
(Other porting
options available
CAVITY/SEAL consult factory.)
ACCESSORIES
SEALS
N = Buna N
V = Viton
TECHNICAL
DATA
9.04.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 180
DMR2-080
Normally Closed, Zero Leak
SOLENOID
Mechanically-Operated Valve
SERIES 8
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
Compact size.
SPECIFICATIONS
DIRECTIONAL
VALVES
60 (4.1)
150 ssu/32 cSt OIL @ 100F/38C Recommended Filtration: Critical Application ISO 17/15/13
Non-Critical Application ISO 20/18/14
PRESSURE DROP psi (bar)
50 (3.4)
Fluids: Mineral-based fluids. For other fluid compatibility, consult factory.
40 (2.8) Cavity/Cavity Tool: 080-2, see page 11.08.2
30 (2.1)
In-Line Body Material: Anodized 6061T6 aluminum
alloy rated at 3000 PSI (207 Bar).
20 (1.4)
TECHNICAL
10 (.7)
DATA
0
0 1.0 2.0 3.0 4.0 5.0
(3.8) (7.6) (11.4) (15.1) (18.9)
FLOW gpm (L/min.)
10179-86 02/11
9.05.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 181
DMR2-080
Normally Closed, Zero Leak
SOLENOID
Mechanically-Operated Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
S. DIA. .63 (16.0)
MOTION
(4.8)
#8 SAE O-RING BOSS
MALE ADAPTER
1.08 (3/4-16 UNF-2B THD.)
(27.4)
.89
(22.6) .88 (22.4) HEX.
CONTROL
.41 TORQUE 20 FT.-LBS.
FLOW
(10.4) (27.1 Nm) MAX.
3.08 .59
(78.2) (15.0)
1.06 FILTER
RELIEF
(26.9) 250 NOM. MICRON
(EFFECTIVE FROM 1.50
2 TO 1 ONLY)
(38.1)
2.00
(50.8)
PRESSURE
.08
CONTROL
(2.0) .27
(6.9)
SPECIAL POPPET CLEARANCE .28 TYP.
REQUIREMENT - CAVITY MUST (7.1)
HAVE .406 (10.31) DIA. MIN.
1.25 .56
1.31 (33.3) DEEP MIN. FOR
PROPER OPERATION.
(31.8) (14.2)
.13 1.63 1.13
SEQUENCE
(3.3) (41.4) (28.7)
2.00
(50.8)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DMR2 - 080 - * - **
DIRECTIONAL
MANUAL RELEASE
VALVES
VALVE
PORTING
CAVITY/SEAL 2N = 1/4 PTF
3N = 3/8 PTF
4T = SAE 4
SEALS 6T = SAE 6
ACCESSORIES
9.05.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 182
DMO-080-2NCSP
Normally Closed, Bi-Directional
SOLENOID
Manual-Operated Valve
SERIES 8
CHECK
DESCRIPTION
A manually-operated cartridge valve designed with positive shut off,
CONTROL
holding applications.
OPERATION
CONTROL
FLOW
Hardened poppet and seat for long life and low leakage.
Low leak valve available.
Positive detent open.
Industry common cavity.
Compact size.
SHUTTLE
SPECIFICATIONS
10136-28 02/11
9.07.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 183
DMO-080-2NCSP
Normally Closed, Bi-Directional
SOLENOID
Manual-Operated Valve
SERIES 8
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DMO - 080 - 2 NC SP - * - * - **
MANUAL PULL
DIRECTIONAL
PORTING
2N = 1/4 PTF
VALVES
3N = 3/8 PTF
4T = SAE 4
CAVITY/SEAL 6T = SAE 6
Omit for Cartridge Only.
(Other porting
options available
consult factory.)
ACCESSORIES
FLOW PATH
L = Low Leak Option
(Omit for Standard)
NORMALLY CLOSED
SEALS
TECHNICAL
N = Buna N
BI-DIRECTIONAL
DATA
V = Viton
9.07.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 184
DPOD-100-2NCP
Pilot To Open, Poppet-Type,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
A cartridge valve designed to block flow in both directions. Free flow
CONTROL
OPERATION
CONTROL
FLOW
In the steady state the poppet is held closed to block flow between
and and and . When the required pilot pressure is achieved
at , the poppet is held open to allow free flow between and or
RELIEF
and . The pilot area ratio port to is 1.3 to 1 and the area ratio
port to is 1.8 to 1.
PRESSURE
CONTROL
Hardened spool and sleeve for long life and low leakage.
Industry common cavity.
Compact size.
SEQUENCE
SPECIFICATIONS
02/11
9.10.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 185
DPOD-100-2NCP
Pilot To Open, Poppet-Type,
SOLENOID
Directional Control Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
1.00 (25.4) HEX.
.38 TORQUE 30 FT.-LBS.
(9.5) (40.7 Nm MAX.)
.59
CONTROL
(14.9)
FLOW
1.25
1.81
(31.8) 3.01
(45.9) (76.5)
2.13
(54.1)
RELIEF
2.63
(66.8)
PRESSURE
CONTROL
1.25 .63
.25 (31.8) .28 TYP.
(6.4) (16.0)
2.00 (7.1)
(50.8) 1.25
2.50 (31.8)
SEQUENCE
(63.5)
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DPOD - 100 - 2 NC P - * - **
DIRECTIONAL
PILOT-OPERATED
VALVES
DIRECTIONAL
CONTROL VALVE PORTING
2N = 1/4 PTF
3N = 3/8 PTF
4T = SAE 4
CAVITY/SEAL 6T = SAE 6
Omit for Cartridge Only.
ACCESSORIES
FLOW PATH
POPPET
TECHNICAL
NORMALLY CLOSED
DATA
9.10.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:34 PM Page 186
DPOD-100-2NOP
Pilot To Close, Poppet-Type,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
valve can be piloted to block flow in both directions. This valve can
MOTION
OPERATION
CONTROL
FLOW
and and . The pilot area ratio port to is 2.0 to 1 and the area ratio
port to is 2.8 to 1.
PRESSURE
CONTROL
Hardened poppet and sleeve for long life and low leakage.
Industry common cavity.
Compact size.
SEQUENCE
SPECIFICATIONS
02/11
9.12.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 187
DPOD-100-2NOP
Pilot To Close, Poppet-Type,
SOLENOID
Directional Control Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
1.00 (25.4) HEX.
TORQUE 30 FT.-LBS. .59
(40.7 Nm MAX.) (14.9)
1.25
CONTROL
(31.8) 3.01
FLOW
.38
(9.5) 2.13 (76.5)
(54.1)
2.63
(66.8)
RELIEF
1.81
(46.1)
PRESSURE
.25
CONTROL
.28 TYP.
(6.4) 1.25 (7.1) .63
(31.8) (16.0)
2.00
(50.8)
1.25
2.50 (31.8)
(63.5)
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DPOD - 100 - 2 NO P - * - **
DIRECTIONAL
PILOT-OPERATED
VALVES
DIRECTIONAL
CONTROL VALVE PORTING
2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
CAVITY/SEAL 8T = SAE 8
Omit for Cartridge Only.
ACCESSORIES
POPPET
TECHNICAL
NORMALLY OPEN
DATA
9.12.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 188
DPOD-100-3
Pilot-Operated, Three-Way, Two-Position,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
The bias spring which is common to port returns the spool to its
original position when the pilot signal is removed.
PRESSURE
pressure to shift.
SPECIFICATIONS
Operating Pressure: 3000 PSI (207 Bar)
Flow: See PRESSURE DROP VS. FLOW graph.
DIRECTIONAL
3
Internal Leakage: 5 in /min. (82cc/min.) max. at 3000 PSI (207 Bar)
PRESSURE DROP VS. FLOW Pilot Pressure: 125 PSI (8.6 Bar)
Temperature: -30F to +250F (-35C to +120C)
Recommended Filtration: ISO 17/15/13
Fluids: Mineral-based fluids. For other fluid compatibility, consult factory.
150 ssu/32 cSt OIL @ 100F/38C
Cavity/Cavity Tool: 100-4, see page 11.10.4
ACCESSORIES
10161-77 02/11
9.20.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 189
DPOD-100-3
Pilot-Operated, Three-Way, Two-Position,
SOLENOID
Directional Control Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DPOD - 100 - 3 - * - 125 - **
DIRECTIONAL
PILOT-OPERATED
VALVES
DIRECTIONAL
CONTROL VALVE PORTING
2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
CAVITY/SEAL
8T = SAE 8
Omit for Cartridge Only.
ACCESSORIES
FLOW PATH
V = Viton
DATA
9.20.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 190
DPOD2-100-3
Pilot-Operated, Externally Vented,
SOLENOID
SERIES 10
CHECK
DESCRIPTION
OPERATION
CONTROL
FLOW
The bias spring returns the spool to its original position when the pilot
signal is removed.
PRESSURE
CONTROL
SPECIFICATIONS
10199-66 02/11
9.22.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 191
DPOD2-100-3
Pilot-Operated, Externally Vented,
SOLENOID
Three-Way, Two-Position, Directional Control Valve
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
( ) Parentheses = Millimeters
HOW TO ORDER
SHUTTLE
DPOD2 - 100 - 3 - * - 125 - **
DIRECTIONAL
PILOT-OPERATED
VALVES
DIRECTIONAL
CONTROL VALVE PORTING
2N = 1/4 PTF
3N = 3/8 PTF
6T = SAE 6
CAVITY/SEAL 8T = SAE 8
Omit for Cartridge Only.
ACCESSORIES
FLOW PATH
PILOT PRESSURE (shift pressure)
125 = 125 PSI (8.6 Bar)
SEALS
TECHNICAL
N = Buna N
DATA
V = Viton
9.22.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 192
DHP2-100
Hand Pump
SOLENOID
SERIES 10
CHECK
DESCRIPTION
flow when the operator is pushed. The inlet and outlet checks
MOTION
OPERATION
CONTROL
FLOW
SPECIFICATIONS
10181-07 02/11
10.01.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 193
DHP2-100
Hand Pump
SOLENOID
SERIES 10
CHECK
INSTALLATION DIMENSIONS
CONTROL
MOTION
4.00
CONTROL
(101.6)
FLOW
MAX
STROKE
1.00 (25.4) HEX.
TORQUE 30 FT.-LBS.
(40.7 Nm MAX.) 6.00
RELIEF
(152.4)
.75
(19.0)
1.50
PRESSURE
(38.1) 2.00
CONTROL
(50.8)
1.27
(32.3)
.28 TYP.
(7.1)
.63
1.25 (16.0)
SEQUENCE
(31.8)
.13 1.63 1.25
(3.3) (41.4) (31.8)
( ) Parentheses = Millimeters 2.00
(50.8)
HOW TO ORDER
SHUTTLE
DHP2 - 100 - * - **
DIRECTIONAL
HAND PUMP PORTING
2N = 1/4 PTF
VALVES
3N = 3/8 PTF
CAVITY/SEAL 6T = SAE 6
8T = SAE 8
Omit for Cartridge Only.
(Other porting options available-
consult factory.)
ACCESSORIES
SEALS
N = Buna N
V = Viton
TECHNICAL
DATA
10.01.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 194
DHP-100
Hand Pump
SOLENOID
SERIES 10
CHECK
DESCRIPTION
flow when the operator is pushed. The inlet and outlet checks
MOTION
OPERATION
CONTROL
FLOW
SPECIFICATIONS
10177-09 02/11
10.02.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 195
DHP-100
Hand Pump
SOLENOID
SERIES 10
CHECK
INSTALLATION DIMENSIONS
45
.88 (22.2) NOMINAL
BEAM INSIDE DIA.
CONTROL
MOTION
4.98
CONTROL
TORQUE 30 FT.-LBS.
(26.5)
FLOW
(40.7 Nm MAX.)
RELIEF
7.00
(177.8)
PRESSURE
CONTROL
.75
1.27 1.50 (19.1)
(32.3) (38.1)
2.00
(50.8)
.28 TYP.
(7.1)
SEQUENCE
1.25 .63
(31.8) (16.0)
.13 1.63 1.25
( ) Parentheses = Millimeters (3.3) (41.4) (31.8)
2.00
(50.8)
HOW TO ORDER
SHUTTLE
DHP - 100 - * - **
DIRECTIONAL
HAND PUMP PORTING
2N = 1/4 PTF
VALVES
3N = 3/8 PTF
CAVITY/SEAL 6T = SAE 6
8T = SAE 8
Omit for Cartridge Only.
(Other porting options available -
consult factory.)
ACCESSORIES
SEALS
N = Buna N
V = Viton
TECHNICAL
DATA
10.02.2
TECHNICAL ACCESSORIES DIRECTIONAL SHUTTLE SEQUENCE PRESSURE RELIEF FLOW MOTION CHECK SOLENOID
DATA VALVES CONTROL CONTROL CONTROL
Notes
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 196
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 197
Recommended
Filtration
SOLENOID
CHECK
CONTROL
MOTION
CONTROL
FLOWRELIEF
STANDARDS
APPLICATION ISO CLEANLINESS CODE RATING
PRESSURE
CONTROL
(PARTICLE SIZE CLASSIFICATION) ISO 4406:1999
SEQUENCE
SHUTTLE
DIRECTIONAL
VALVES
ACCESSORIES
TECHNICAL
DATA
02/08
11.01.1
ZP42
Cavity
SOLENOID
ZERO PROFILE
CHECK
CONTROL
MOTION
CONTROL
FLOW
RELIEF
PRESSURE
CONTROL
SEQUENCE
SHUTTLE
ZP42 Cavity
Rough Drill P/N 10206-12
Finish Form Tool P/N 10206-13
DIRECTIONAL
VALVES
ACCESSORIES
TECHNICAL
DATA
11.04.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 199
ZP43
Cavity
SOLENOID
ZERO PROFILE
CHECK
CONTROL
MOTION
.828
SPOTFACE
CONTROL
.002 M A M
FLOW
.492
100 .487
12
7/16-20-2B THD. .395 .002 M A M
.391
.002 M A M
B
RELIEF
.315 .002 M A M
-B-
.313
.010
.283 -A-
.281 .115
.100
PRESSURE
CONTROL
MAX. 1.575 80 .015
45 R .005
MIN. .769
12
SEQUENCE
.075
.293 .379
.093
.672
SHUTTLE
.168
80
MAX. R.062
.250
DIRECTIONAL
MAX.
ZP43 Cavity
Rough Drill P/N 10201-56
Finish Form Tool P/N 10201-57
TECHNICAL
DATA
11.04.3
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 200
ZP62
Cavity
SOLENOID
ZERO
ZERO PROFILE
CHECK
CONTROL
MOTION
.969
SPOTFACE
.002 M A M
CONTROL
.621
.616
FLOW
B
100 .515 .002 M A M
.510
.010
9/16-18UNF-2B THD. 12 80 ZP62 Cavity
.488 -A-
.002 M A M .486 Rough Drill P/N
RELIEF
.015
R .005 1.257
20 .250
MAX.
SEQUENCE
.250
MAX.
ZP62 Cavity
SHUTTLE
.488
.486
VALVES
.010
.438
9/16-18UNF-2B THD. .377 12 -A- .112
.375
.097
.002 M A M
-B-
.801
.739 45 MIN.THD.
ACCESSORIES
1.244 .883
1.787
.015
R .005 2.064
20
TECHNICAL
.250
DATA
MAX.
TYP. 30
UNLESS OTHERWISE SPECIFIED
Specifications subject to change, 2 PLACE DIM .01
consult factory. 3 PLACE DIM .005
All dimensions in inches. ANGLE .5 .312
MAX.
11.06.2
ZP63 Cavity
.616
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 201
B
100 .515 .002 M A M
.510
.010
9/16-18UNF-2B THD. 12 80 ZP62 Cavity
.488 -A-
Rough Drill P/N
-B-
.002 M A M .486
ZP63
FinishorFm Tool P/N
.500
Cavity
SOLENOID
.112 MIN.THD.
45 .097 .739 .883
.015
R .005 1.257
ZERO PROFILE
.250
CHECK
20
MAX.
.250
MAX.
CONTROL
MOTION
.969
SPOTFACE
CONTROL
.621 .002 M A M
FLOW
.616 100
.515
.510
80
.002 M A M
B
.488
.486
RELIEF
.010
.438
9/16-18UNF-2B THD. .377 12 -A- .112
.375
.097
.002 M A M
PRESSURE
-B-
CONTROL
.801
.739 45 MIN.THD.
1.244 .883
1.787
SEQUENCE
.015
R .005 2.064
20
.250
MAX.
SHUTTLE
TYP. 30
.312
MAX.
DIRECTIONAL
VALVES
ZP63 Cavity
ZP63 Cavity
Rough Drill
Rough Drill P/N 10201-54
P/N 10201-54
Finish Form
Finish Tool
orFm Tool P/N 10201-54
P/N 10201-54
ACCESSORIES
TECHNICAL
DATA
11.06.3
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 202
080-2
Cavity
SOLENOID
SERIES 8
CHECK
CONTROL
MOTION
1.062
SPOTFACE
CONTROL
FLOW
.816 .002 M A M
.811
100
.558
RELIEF
15 .501 -A-
.499
B
63
.010
.025 MAX.
PRESSURE
CONTROL
45
.115 .500
.100 MIN.THD. .562
3/4-16UNF-2B .750
.002 M A M
SEQUENCE
-B- 30 1.125
.010
R .005
.250
MAX.
SHUTTLE
.438
MAX.
080-2 Cavity
Rough Drill P/N 10131-76
DIRECTIONAL
VALVES
11.08.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 203
080-2P
Cavity
SOLENOID
PILOT PISTON KITS FOR MANIFOLD DESIGNS
SERIES 8
CHECK
CONTROL
MOTION
CONTROL
FLOWRELIEF
PRESSURE
CONTROL
SEQUENCE
SHUTTLE
DIRECTIONAL
VALVES
ACCESSORIES
TECHNICAL
080-2P Cavity
DATA
11.08.2P
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 204
080-3
Cavity
SOLENOID
SERIES 8
CHECK
CONTROL
MOTION
1.188
SPOTFACE
CONTROL
100
FLOW
.816 .002 M A M
.811
63
15 .627 .002 M A M
.625
RELIEF
63
.564 -A-
.562
B
.010
PRESSURE
CONTROL
45 .031 MAX.
3/4-16UNF-2B .500
.115 MIN.THD.
.002 M A M .100 .578
-B- .719
SEQUENCE
1.141
.010 1.270
R .005
1.703
.234
SHUTTLE
MAX. TYP.
R.062
TYP.
.438
MAX.
DIRECTIONAL
VALVES
080-3 Cavity
Rough Drill Cavity
080-3 P/N 10131-80
FinishRough
Form Tool
Drill P/N 10131-81
P/N-10131-80
Finish Form Tool P/N-10131-81
ACCESSORIES
TECHNICAL
DATA
11.08.3
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 205
080-4
Cavity
SOLENOID
SERIES 8
CHECK
CONTROL
MOTION
1.188
SPOTFACE
CONTROL
FLOW
.816 .002 M A M
.811
100 63
.627 .002 M A M
.625
RELIEF
15 63
.564 .002 M A M
.562
63
.502 -A-
.500
PRESSURE
CONTROL
B
63
.010
45 .031 MAX.
SEQUENCE
3/4-16UNF-2B .115 .500
.100 MIN.THD. .578
.002 M A M .719
-B-
1.141
.010 1.270
R .005 1.700
SHUTTLE
1.830
.234 2.210
MAX. TYP.
DIRECTIONAL
R.062
TYP.
VALVES
.438
MAX.
ACCESSORIES
080-4 Cavity
Rough Drill P/N-10132-15
Finish Form Tool P/N-10132-16
TECHNICAL
DATA
11.08.4
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 206
100-2
Cavity
SOLENOID
SERIES 10
CHECK
CONTROL
MOTION
1.188
SPOTFACE
CONTROL
FLOW
100
.947 .002 M A M
.943
63
RELIEF
15 .627 -A-
.625
B
.010
.031 MAX.
PRESSURE
CONTROL
45
.625
.115 MIN.THD.
.100 .719
7/8-14UNF-2B .938
SEQUENCE
.002 M A M
30 1.312
-B-
.438 .010
R .005
MAX.
SHUTTLE
R.062
.562
MAX.
DIRECTIONAL
VALVES
100-2 Cavity
Rough Drill P/N-10131-82
Finish Form Tool P/N-10131-83
ACCESSORIES
TECHNICAL
DATA
11.10.2
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 207
100-2P
Cavity
SOLENOID
PILOT PISTON KITS FOR MANIFOLD DESIGNS
SERIES 10
CHECK
DCV-100-P
(pp 2.14.1)
CONTROL
MOTION
PILOT PISTON AREA TO PILOT
SEAT AREA RATIO IS 3.5:1.
KIT WITH SPRING IS RECOMMENDED
FOR CHECK VALVES 30 PSI CRACK
OR LOWER.
CONTROL
FLOWRELIEF
KIT, PILOT PISTON/SPRING
(INCLUDES SEALS)
P/N-10146-76
KIT, PILOT PISTON
(INCLUDES SEALS)
PRESSURE
P/N-10146-70
CONTROL
1.188 100
SEQUENCE
SPOTFACE 15
.002 M A M
.947
.943
63
-A- .627
B
.625 45
32
.010
SHUTTLE
.002 M A M .564
.562 .031 MAX.
.010 .115
R .005 .625
.100 MIN.THD. .719
DIRECTIONAL
7/8-14UNF-2B
.002 M A M .938
VALVES
1.468
-B-
1.688
R.062
.438 2.750
MAX.
ACCESSORIES
.375
MAX.
20
TECHNICAL
100-2P Cavity
DATA
11.10.2P
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 208
100-3
Cavity
SOLENOID
SERIES 10
CHECK
CONTROL
MOTION
1.188
SPOTFACE
CONTROL
FLOW
.947 .002 M A M
.943
100 63
RELIEF
.690 .002 M A M
.688
15 63
.627 -A-
.625
PRESSURE
B
CONTROL
.010
.031 MAX.
45
SEQUENCE
.625
7/8-14UNF-2B .115 MIN.THD.
.100 .719
.002 M A M
.850
-B-
1.344
.010 1.500
SHUTTLE
R.062 R .005
TYP. 1.875
.250
MAX. TYP.
DIRECTIONAL
VALVES
.562
MAX.
ACCESSORIES
100-3 Cavity
Rough Drill P/N-10131-84
100-3 Cavity
Finish Form Tool P/N-10131-85
Rough Drill P/N 10131-84
Finish Form Tool P/N 10131-85
TECHNICAL
DATA
11.10.3
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 209
100-3S
Cavity
SOLENOID
SERIES 10
CHECK
CONTROL
MOTION
1.188
SPOTFACE
CONTROL
100
FLOW
.947 .002 M A M
.943
15
.814 .002 M A M
.810
RELIEF
63
.752 .002 M A M
.750
63
PRESSURE
B
CONTROL
.690 -A-
.688
.010
45 .031 MAX.
SEQUENCE
.115 .562
.650
.100
.010
R .005 1.219
1.515
.125 1.875
MAX.
SHUTTLE
7/8-14UNF-2B
.002 M A M
-B-
R.062
DIRECTIONAL
.531
VALVES
MAX.
R.062
.625
MAX.
ACCESSORIES
100-3S Cavity
Rough Drill P/N-10194-27
Finish Form Tool P/N-10194-28
TECHNICAL
DATA
100-3S Cavity
Rough Drill P/NUNLESS
10194-27
OTHERWISE SPECIFIED
Finish Form Tool P/NSpecifications
10194-28 subject to change,
consult factory.
2 PLACE DIM .01
3 PLACE DIM .005
All dimensions in inches. ANGLE .5
11.10.3S
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 210
100-4
Cavity
SOLENOID
SERIES 10
CHECK
CONTROL
MOTION
1.188
SPOTFACE
CONTROL
FLOW
.947 .002 M A M
.943
63
.752 .002 M A M
RELIEF
.750
100 63
.690 .002 M A M
.688
PRESSURE
CONTROL
63
15 .627 -A-
.625
B
.010
.031 MAX.
45
SEQUENCE
.625
.010 .115 .719
R .005 MIN.THD.
.100 .875
SHUTTLE
7/8-14UNF-2B 1.344
.002 M A M
-B- 1.500
R.062 1.969
TYP.
2.125
DIRECTIONAL
2.500
VALVES
.250
MAX.TYP.
ACCESSORIES
.562
MAX.
100-4 Cavity
Rough Drill P/N 10131-86
Finish Form Tool P/N 10131-87
TECHNICAL
DATA
100-4 Cavity
11.10.4 Rough Drill P/N 10131-86
Finish Form Tool P/N 10131-87
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 211
100-4L
Cavity
SOLENOID
SERIES 10
CHECK
CONTROL
MOTION
1.188
SPOTFACE
CONTROL
FLOW
.947 .002 M A M
.943
63
.752 .002 M A M
100 .750
63
RELIEF
.690 .002 M A M
.688
63
15 -A-
.627
.625
PRESSURE
CONTROL
.010
.031 MAX.
45
SEQUENCE
.100 MIN.THD. .875
1.344
1.500
.010 2.094
R .005
SHUTTLE
7/8-14UNF-2B R.062 TYP. 2.375
.002 M A M
-B- 2.750
2X .250
MAX.
DIRECTIONAL
VALVES
.500
MAX.
.562
ACCESSORIES
MAX.
100-4L Cavity
100-4L Cavity P/N 10164-16
Rough Drill
Rough Drill P/N 10164-16
Finish Form Tool P/N 10164-17
TECHNICAL
11.10.4L
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 212
120-3
Cavity
SOLENOID
SERIES 12
CHECK
CONTROL
MOTION
1.500
SPOTFACE
.002 M A M 1.152
1.148 100
CONTROL
63
FLOW
.002 M A M .978 15
.972
63
.002 M A M .939
.937
RELIEF
B
63
-A- .877
.875
.010
.031 MAX.
PRESSURE
45
CONTROL
.145
1-1/16-12UNF-2B .130 .810
.002 M A M .010 1.120
R .005
-B- 1.400
SEQUENCE
2.090
2.370
2.890
SHUTTLE
DIRECTIONAL
VALVES
R.062
TYP.
.500
MAX. TYP.
ACCESSORIES
.781
MAX.
120-3 Cavity
Rough Drill P/N 10144-91
Finish Form Tool P/N 10144-92
TECHNICAL
DATA
11.12.3
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 213
160-3S
Cavity
SOLENOID
SERIES 16
CHECK
CONTROL
MOTION
1.750
SPOTFACE
CONTROL
FLOW
1.403 .002 M A M
1.399
100 63
1.128 .002 M A M
1.126
63
RELIEF
15
1.003 -A-
1.001
B
.010
.031 MAX.
PRESSURE
CONTROL
45
.656 .688
.145
.130 MIN.THD.
.010 .812
SEQUENCE
R .005 1.469
1.812
.250
MAX. 2.188
1-5/16-12UNF-2B
SHUTTLE
.002 M A M .625
-B- MAX.
R.062
TYP.
DIRECTIONAL
VALVES
.750
MAX.
160-3S Cavity
ACCESSORIES
11.16.3S
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 214
NC**
Cavity
SOLENOID
SERIES NC
CHECK
.275 .396
.273 .392
.108 A .157 A
.030X45 .106 .155
EFF. THD. .030X45 EFF. THD.
CONTROL
MOTION
.203 MAX.
.141 MAX.
CONTROL
.396
.392
.220 A
.030X45 .218
EFF. THD.
.327 .300
.500
SEQUENCE
.706
.266 MAX.
.002 M A M
NC25 Cavity
Step Drill P/N 10131-96
Tap Steel P/N 10131-94
Tap Aluminum P/N 10131-95
DIRECTIONAL
VALVES
.460 .658
.456 .654
.282 A .345 A
.030X45 .280 .343
.030X45 EFF. THD.
EFF. THD.
ACCESSORIES
.312
.312 .532
.416 .620 .775
.838 1.032
.406 MAX.
.328 MAX.
.5000 P.D.27 AT LARGE .6960 P.D.27 AT LARGE
END DRYSEAL NPTF R.005 MAX. END DRYSEAL NPTF
R.005 MAX.
.265 MAX. .002 M A M .328 MAX. .002 M A M
TECHNICAL
11.21.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 215
S*10
Cavity
SOLENOID
SERIES S
CHECK
1.062 1.188
SPOTFACE SPOTFACE
100 .816 .002 M A M 100 .947 .002 M A M
.942
CONTROL
.811
MOTION
15 15
.564 A .626 A
.010 B
.010 B
.562 .624
63
63
CONTROL
FLOW
.115 .500 .650 .115 .562
.562 .719 .100
.100 .875
1.062 MIN. THD.
MIN. THD.
.219 .320 1.250
R.010/.005 30 R.010/.005
30
RELIEF
3/416UNF2B 7/814UNF2B
B .320 B
.219
R.030/.020 R.030/.020
PRESSURE
CONTROL
S210 Cavity S310 Cavity
Rough Drill P/N 10132-05 Rough Drill P/N 10132-07
Finish Form Tool P/N 10132-06 Finish Form Tool P/N 10132-08
SEQUENCE
SHUTTLE
1.500
SPOTFACE
1.153 .002 M A M
100
1.148
15
.010 B
.813 A
DIRECTIONAL
.811
VALVES
63
45 .025 MAX.
.145 .750
.950 .130 1.212
1.625
MIN. THD.
.400
ACCESSORIES
30 R.010/.005
1 1/1612UN2B
B
.400
R.030/.020
S410 Cavity
TECHNICAL
11.22.1
R05-2 R06-2 R08-2 spread 3/6/11 9:14 PM Page 1
R05-2
Cavity
SOLENOID
SERIES 050
CHECK
CONTROL
MOTION
CONTROL
FLOW
63
1.024
63 .002 A
PRESSURE
CONTROL
.087
.079
.714
45 .704
.982
1.303
1.295
63
35
SEQUENCE
.020
.406
MAX.
R .039
.030
SHUTTLE
63
.395 .002 A
.394
.001
63
.545
.543
DIRECTIONAL
VALVES
R05-2 CAVITY
ACCESSORIES
TECHNICAL
DATA
11.25.2
R05-2 R06-2 R08-2 spread 3/6/11 9:14 PM Page 2
R06-2
Cavity
SOLENOID
SERIES 060
CHECK
CONTROL
MOTION
1.034
CONTROL
1.013
FLOW
63
.004 A
.878
.874
A
.002 A
.654 15
RELIEF
.004
M20 X 1.5 THREAD X .630 R.004 .085 .126
MIN FULL THREAD DEPTH 63 .118 63
PRESSURE
CONTROL
.928 .772
45
1.280 1.303
1.295
1.500
SEQUENCE
59
60
.406
MAX.
R.004
63
SHUTTLE
35
.0008
.002 A
63
.458
.448
DIRECTIONAL
.002 A
VALVES
R06-2 CAVITY ACCESSORIES
TECHNICAL
DATA
11.26.2
R05-2 R06-2 R08-2 spread 3/6/11 9:14 PM Page 3
R08-2
Cavity
SOLENOID
SERIES 080
CHECK
CONTROL
MOTION
63
1.181
CONTROL
FLOW
15
.996
.992 .004 A
RELIEF
.002 A
.031 A
R.008 M24X1.5
63 MAX.
PRESSURE
CONTROL
.630 .091
.807 .079
1.200
MAX.
1.461
1.772 1.453
MIN. 30 .512
SEQUENCE
R.020
.020
SHUTTLE
35
63
.512 .002 A
DIRECTIONAL
VALVES
63
.709 .002 A
ACCESSORIES
R08-2 CAVITY
TECHNICAL
DATA
11.28.2
SOLENOID CHECK MOTION FLOW RELIEF PRESSURE SEQUENCE SHUTTLE DIRECTIONAL ACCESSORIES TECHNICAL
CONTROL CONTROL CONTROL VALVES DATA
Notes
R05-2 R06-2 R08-2 spread 3/6/11 9:14 PM Page 4
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 216
Solenoid Coil
Features/Specifications
SOLENOID
CHECK
MAGNET WIRE: ALL 100 SERIES ARE THERMAL CLASS 200C., NEMA PUB, NO. MW1000
RELIEF
LEAD WIRES: 18/20 GAUGE. MEETS SAE J1128 XLPE, TYPE SXL.
PRESSURE
CONTROL
A.C. VOLTAGE COILS: INTERNALLY FULL WAVE RECTIFIED TO SUPPLY THE COIL WINDING WITH D.C.
CURRENT. THEREFORE THE COIL WINDING HAS NO INRUSH CURRENT MAKING
IT SUITABLE FOR 50 OR 60 HERTZ (Hz) CYCLE APPLICATIONS. THE RECTIFIERS
USED IN A.C. COILS MAY REQUIRE PROTECTION FROM TRANSIENT OVER
VOLTAGES EXCEEDING 1000 VOLTS. PROTECT RECTFIED A.C. COILS BY
SEQUENCE
03/11
11.30.0
dream-coil spread:Deltrol2004Run8 3/6/11 9:11 PM Page 1
Dream Coil
Data
SOLENOID
SERIES 8
16 WATT
CHECK
INITIAL CURRENT
SPECIFICATIONS VOLTS OHMS DRAW (AMPS)
CONTROL
20 DC 25.0 .80
MOTION
Ambient Operating Temperature: 212F/100C. 24 DC 35.8 .67
Encapsulating Material: Thermoplastic Polyester (PET) (Rynite 415 HP).
Termination Options: See below and on the following pages.
Environmental: IP69K for Deutsch, Metri-Pack and Amp Junior timer-style coils.
CONTROL
FLOW
DOUBLE LEADS 1.62
(41.2)
14
(355.6)
RELIEF
.72
CODE - **DE (18.4)
PRESSURE
CONTROL
12 DC 10244-28 RED
20 DC 10258-75
24 DC 10257-41 BLUE
SEQUENCE
1.42
(36.0)
FOR INTERNAL DIODE CONSULT FACTORY
SHUTTLE
1.62 14
SINGLE LEAD (41.2) (355.6)
.72
CODE - **SE (18.4)
DIRECTIONAL
(31.7)
10 DC 10257-44 GREEN
VALVES
12 DC 10244-29 RED
20 DC 10258-76
24 DC 10257-45 BLUE
1.42
(36.0)
ACCESSORIES
TECHNICAL
DATA
03/11
11.30.1
dream-coil spread:Deltrol2004Run8 3/6/11 9:11 PM Page 2
Dream Coil
Data (continued)
SOLENOID
SERIES 8
CHECK
1.62 .44
DOUBLE SPADE (41.2)
.72
(11.1)
(18.7)
CODE - **BE
CONTROL
MOTION
1.42
(36.0)
RELIEF
1.62 .44
SINGLE SPADE
PRESSURE
(41.2) (11.1)
CONTROL
.72
(18.7)
CODE - **AE
1.42
(36.0)
SHUTTLE
1.72 .45
SINGLE STUD
DIRECTIONAL
(43.7) (11.4)
.72
VALVES
(18.4)
CODE - **EE
24 DC 10257-54
1.42
(36.0)
TECHNICAL
DATA
03/11
11.30.2
dream-coil spread:Deltrol2004Run8 3/6/11 9:11 PM Page 3
Dream Coil
Data (continued)
SOLENOID
SERIES 8
CHECK
DEUTSCH 1.45
(36.9)
.73
(18.6)
.72
CODE - **UE (18.4)
CONTROL
MOTION
VOLTS PART NO. TERMINATION: 1.25
10 DC 10257-55 INTEGRAL DEUTSCH CONNECTOR (31.7)
DT04-2P
12 DC 10244-24 MATING CONNECTOR
20 DC 10257-56 DT06-2S
24 DC 10257-57
CONTROL
FLOW
1.42
(36.0)
RELIEF
FOR INTERNAL DIODE CONSULT FACTORY
1.45 .69
METRI-PACK
PRESSURE
CONTROL
(36.9) (17.5)
.72
CODE - **PE (18.4)
SEQUENCE
12 DC 10244-25
20 DC 10257-59
24 DC 10257-60
1.42
SHUTTLE
(36.0)
DIRECTIONAL
AMP JUNIOR TIMER 1.45
(36.9)
.66
(16.8)
VALVES
.72
CODE - **JE (18.4)
12 DC 10244-26
20 DC 10257-62
ACCESSORIES
24 DC 10257-63
1.42
(36.0)
03/11
11.30.3
Solenoid Coil
Data
SOLENOID
SERIES 8
16 WATT
CHECK
INITIAL CURRENT
VOLTS OHMS DRAW (AMPS)
SPECIFICATIONS
10 DC 6.2 1.60
Wattage: Nominally 16 watt at 68F./20C. 12 DC 9.0 1.33
CONTROL
Termination Options: See below and on the next page. DRESISTANCE CANNOT BE MEASURED
FLOW
ON AC COIL ASSEMBLIES
DOUBLE LEADS
RELIEF
CODE - **DS
12 DC 10184-42 RED
24 DC 10184-37 BLUE
120 AC 10184-49 BLACK
240 AC 10184-53 YELLOW
SEQUENCE
SINGLE LEAD
CODE - **SS
SHUTTLE
DOUBLE SPADE
ACCESSORIES
CODE - **BS
VOLTS PART NO.
TERMINATION:
10 DC 10221-46 1/4 MALE QUICK-CONNECT
12 DC 10216-12 PER SAE J858A (TYPE 1B)
20 DC 10222-51
TECHNICAL
24 DC 10216-11
DATA
120 AC 10222-49
240 AC 10222-50
11.31.1
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 219
Solenoid Coil
Data (continued)
SOLENOID
SERIES 8
CHECK
SINGLE SPADE
CODE - **AS
CONTROL
VOLTS PART NO.
MOTION
TERMINATION:
10 DC 10222-46 1/4 MALE QUICK-CONNECT
PER SAE J858A (TYPE 1B)
12 DC 10221-30
24 DC 10221-47
CONTROL
FLOWRELIEF
SINGLE STUD
CODE - **ES
PRESSURE
CONTROL
VOLTS PART NO. TERMINATION:
10 DC 10196-60 8-32 MALE STUD
WITH BRASS NUTS
12 DC 10196-61
24 DC 10196-62
SEQUENCE
SHUTTLE
DEUTSCH
CODE - **US
DIRECTIONAL
DT04-2P
12 DC 10222-99 MATING CONNECTOR
VALVES
DT06-2S
20 DC 10228-95
24 DC 10228-52
03/11
11.31.2
Solenoid Coil
Data
SOLENOID
SERIES 10
19 WATT 22 WATT
CHECK
20 DC 18.2 1.10
MOTION
ON AC COIL ASSEMBLIES
2.19
(55.6)
DOUBLE LEADS .88
(22.4)
RELIEF
CODE - **D
1.50 1
(38.1)
VOLTS PART NO. LEAD COLOR
10 DC 10163-99 GREEN
PRESSURE
CONTROL
.41
(10.4)
12 DC 10162-76 RED
18 GA.
20 DC 10223-97
14.00
24 DC 10162-77 BLUE (355.6)
1.00
(25.4)
LEAD WIRES: 18/20 GAUGE MEETS SAE J1128 XLPE, TYPE SXL.
2.19
(55.6)
SINGLE LEAD .88
(22.4)
CODE - **S
SHUTTLE
1.50
(38.1)
14.00
(355.6) 2
VALVES
2.00
(50.8)
1.00
(25.4)
LEAD WIRES: 18/20 GAUGE MEETS SAE J1128 XLPE, TYPE SXL.
HIRSCHMANN
ACCESSORIES
2.38 .50
(60.5) (12.7)
.88
(22.4)
CODE - **H
1.50
(38.1)
VOLTS PART NO. 7 1.83 RED D1D 10162-76 D1S 10164-10
2 26 .92 BLUE D2D 10162-77 D2S 10164-11
10 DC 10164-02 TERMINATION: 3 59 .61 GRAY D3D 10163-97
. 4 105 .46 ORANGE D4D 10163-98
12 DC 10162-78 HIRSCHMANN GSR 200
1 .18 BLACK A5D 10162-82
(2 POLE + GROUND APPLIANCE PLUG)
TECHNICAL
2.00
240 AC 10162-85 (50.8)
GSR 200
( 03/11
11.32.1
1.50 1.50
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 221 (38.1) (38.1)
.41 .41
(10.4) (10.4)
Data (continued)
SOLENOID
2.00 2.00
(50.8) (50.8)
1.00 1.00
(25.4) (25.4)
CHECK
(55.6) (55.6) (60.5) (12.7)
.88 .88 .88
CONDUIT (FEMALE 1/2-14 NPT) (22.4) (22.4) 2.38
(60.5)
.63
(16.0)
(22.4)
.88
2.19
(55.6)
.88
(22.4) (22.4)
CODE - **C 1.50 1.50 1.50
(38.1) (38.1) (38.1)
1.50 1.50
CONTROL
VOLTS PART NO. LEAD COLOR
MOTION
(38.1) (38.1)
.75
.41 .41 (19.1)
10 DC 10164-05 GREEN (10.4) (10.4) 24.00
(609.6)
12 DC 10162-80 RED 18 GA. 18 GA.
24 DC 10162-81 BLUE 14.00 14.00
(355.6) (355.6) 2.00
120 AC 10162-86 BLACK (50.8)
CONTROL
2.00 2.00
240 AC 10162-87 YELLOW
FLOW
2.00 2.00 (50.8) (50.8)
(50.8) (50.8)
1.00 1.00 18 GA.
(25.4) (25.4)
**H
HIRSCHMANN GSR 200
LEAD WIRES: 18/20 GAUGE MEETS SAE J1128 XLPE, TYPE
**D
SXL. **C
**S 2.38CONDUIT (FEMALE
(2 POLE + GROUND APPLI-
ANCE PLUG) TO DIN 43650
**B
2.19 2.19 1/2-14
.50 NPT) DOUBLE SPADE
(55.6) DOUBLE LEADS
(55.6) SINGLE LEAD (D*S
(60.5)ONLY) (12.7) 1/4" MALE QUICK-CON
RELIEF
.88 .88 .88 PER SAE J858A (TYP
(22.4) (22.4) (22.4)
DOUBLE SPADE 2.38 .63 2.19
(55.6)
2.25
(60.5) (16.0) (57.2)
.88 22 .88
WATT NOMINAL .88 COIL ASSEM
CODE - **B (38.1)
1.50 1.50 (22.4)
(38.1)
1.50
(38.1)
(22.4) INITIAL
VOLTS OHMS CURRENT
DRAW
LEAD **D
(22.4)
D*S **H
(AMPS) COLOR
PRESSURE
CONTROL
12 DC 7 1.83 RED D1D 10162-76 D1S 10164-10 D1H 10162-7
1.50 1.50 1.50
BLUE .50 D2D 10162-77
VOLTS PART NO. .41 (38.1) .41
24 DC
(38.1)
26 .92
(12.7) (38.1)
D2S 10164-11 D2H 10162-7
(10.4) (10.4) .75 36 DC 59 .61 GRAY D3D 10163-97 D3H 10164-0
(19.1)
10 DC 10164-08 TERMINATION:
24.00
48 DC 105 .46 ORANGE D4D 10163-98 D4H 10164-0
18 GA. 1/4 MALE QUICK-CONNECT
18 GA. 120 AC 496 .18 BLACK A5D 10162-82 A5H 10162-8
12 DC 10162-91 14.00 PER SAE J858A (TYPE 1B)
(609.6)
240 AC 1830 .18 YELLOW A6D 10162-83 A6H 10162-8
14.00
20 DC 10234-53 (355.6) (355.6) 2.00 RESISTANCE CANNOT BE MEASURED ON A.C. COIL ASSEMBLIES.
(50.8)
24 DC 10162-92
SEQUENCE
2.00 2.00 .38 .44
120 AC 10162-90
(50.8) 2.00(50.8) 2.00
(50.8)
(9.7) 2.00 (11.2)
1.00 (50.8) 1.00 (50.8)
240 AC 10164-09 (25.4) (25.4)
**H 1.00 1.00
18 GA.
HIRSCHMANN GSR 200 (25.4) (25.4)
(2 POLE + GROUND APPLI-
**D **S ANCE PLUG) TO DIN 43650
DOUBLE LEADS SINGLE LEAD (D*S
**CONLY) **B **E
CONDUIT (FEMALE 1/2-14 NPT) DOUBLE SPADE SINGLE STUD
1/4" MALE QUICK-CONNECT 10-32 MALE STUD WITH
PER SAE J858A (TYPE 1B) 2 BRASS NUTS AND 1 STEEL
SHUTTLE
2.38 .63 2.19 2.25
SINGLE STUD .88
(60.5) (16.0) .88
(55.6)
.88
(57.2)
EXTERNAL TOOTH LOCKWASHER
DIRECTIONAL
(609.6)
48 DC 105 .46 ORANGE D4D 10163-98 D4H 10164-01 D4C 10164-04 D4B 10164-07
10-32 MALE STUD WITH
12 DC 10164-13 120 AC 496 .18 BLACK A5D 10162-82 A5H 10162-84 A5C 10162-86 A5B 10162-90
VALVES
2 BRASS
240 AC NUTS
1830 AND.18 1YELLOW
STEEL A6D 10162-83 A6H 10162-85 A6C 10162-87 A6B 10164-09
24 DC 10164-14 EXTERNAL TOOTH LOCKWASHER
RESISTANCE CANNOT BE MEASURED ON A.C. COIL ASSEMBLIES. OTHER COIL OPTIONS AVAILABLE-CONSULT FACTORY.
.38 .44
2.00 2.00 (9.7) 2.00 (11.2)
(50.8) (50.8) (50.8)
18 GA. 1.00 1.00
(25.4) (25.4)
12 DC 7 1.83 RED D1D 10162-76 D1S 10164-10 D1H 10162-78 D1C 10162-80 D1B 10162-91 D1E 10164-13
24 DC 26 .92 BLUE D2D 10162-77 D2S 10164-11 D2H 10162-79 D2C 10162-81 D2B 10162-92 D2E 10164-14
36 DC 59 .61 GRAY D3D 10163-97 D3H 10164-00 D3C 10164-03 D3B 10164-06
48 DC 105 .46 ORANGE D4D 10163-98 D4H 10164-01 D4C 10164-04 D4B 10164-07
TECHNICAL
120 AC 496 .18 BLACK A5D 10162-82 A5H 10162-84 A5C 10162-86 A5B 10162-90
DATA
240 AC 1830 .18 YELLOW A6D 10162-83 A6H 10162-85 A6C 10162-87 A6B 10164-09
RESISTANCE CANNOT BE MEASURED ON A.C. COIL ASSEMBLIES. OTHER COIL OPTIONS AVAILABLE-CONSULT FACTORY.
11.32.2
TOC 3/6/11 11:43 PM Page 13
Notes
Project1_Layout 1 1/30/14 8:57 AM Page 1
Notes
TOC 3/6/11 11:43 PM Page 13
Notes
Project1_Layout 1 1/30/14 8:57 AM Page 1
Notes
2011 Deltrol Catalog:Deltrol2004Run8 3/6/11 11:35 PM Page 222
Warranty and
Disclaimer
WARRANTY
Deltrol Fluid Products Division/Deltrol Corp. warrants each product manufactured by it to be free from defects
in material and workmanship under normal use and service appearing within one (1) year. The obligations of
Deltrol Fluid Products Division/Deltrol Corp. and the right of the purchaser under this warranty are limited to
repair or replacement (at the option of Deltrol Fluid Products Division/Deltrol Corp.) at the factory. The
purchaser must give notice of any defect within one (1) year from the date of purchase and must return the
product intact, at its expense. Deltrol Fluid Products Division/Deltrol Corp. will have no responsibility to repair
or replace any product which has been repaired or altered by anyone other than Deltrol Fluid Products
Division/Deltrol Corp., or which has been subjected to misuse, negligence, accident, incorrect connection, or
improper installation.
This warranty is in lieu of any other warranties, express or implied; and seller specifically disclaims
any implied warranty or merchantability of fitness for any particular purpose.
The liability of Deltrol Fluid Products Division/Deltrol Corp. with respect to products that it sells is limited to
performance under the warranty set forth above.
Deltrol Fluid Products Division/Deltrol Corp. shall not be subject to and disclaims: (A) Any other
obligations or liabilities arising out of breach of contract or of warranty, (B) Any obligations
whatsoever arising from tort claims (including negligence and strict liability claims) or arising under
other theories of law with respect to goods sold or any undertakings, acts or omissions relating
thereto, and (C) All consequential, incidental, special and contingent damages whatsoever.
WARNING
The products shown in this catalog were designed and developed for use in fluid power applications.
Do not use the products in other applications without the express written approval of Deltrol Fluid
Products Division/Deltrol Corp. Misuse of the products, including use in other applications, may cause
death, serious injury or property damage.
NOTICE
Deltrol Fluid Products Division/Deltrol Corp. reserves the right to change designs and/or specifications without
notice. Although it has attempted to check the data, dimensions and tables in this catalog, Deltrol Fluid
Products Division/Deltrol Corp. will have no responsibility for errors or omissions that it may contain.
11.99.1
D
Please visit us at E
Cartridge Valves &
L Integrated Circuit
www.deltrolfluid.com
T Manifolds
for information on these other Deltrol product lines: R
Hydraulic Integrated Circuit Manifolds O
In-Line Flow Control, Needle, Check and Accessory Valves
Custom Solutions for Your Fluid Power and Fluid Control Demands L
P
R
O
Valve Specialists D
to the Fluid Power Industry. U
C
T
S
www.deltrolfluid.com
ISO 9001:2008
CERTIFIED