You are on page 1of 14

Features:

True Multiplex 6 Channel Distributed Audio


Integrated Fire Phone, Area of Rescue VoiceNET
and Fan & Damper Control capability
Modular System - components added as needed
High Rise Voice
Integrated 2 Channel Digital Message Repeater
Live Microphone Page to any zone
Evacuation System
Fast RS-485 Communication Protocol SYSTEM

Fully Supervised RESET

Easy Installation and Operation


PAGE
ALL-CALL

Natural Sound Voice Recordings FAULT


SILENCE PAGING
CONTROL
Built in Alarm and Alert Signals
Up to 4 Minute Message Capacity
Works with 12VDC or 24VDC Fire Alarm Panel
Works with Analog/Addressable and
Microprocessor based Fire Alarm Panels.
3 Minute Message Restart on Microphone Key
Made in the USA.

277-96-E
6911-1446:103
LISTED
Description: #S5661
The Hochiki VoiceNET High Rise Evacuation
System operates in conjunction with the Fire Alarm
Control Panel (FACP) in a building to provide
automatic response to life safety emergencies.

The Hochiki VoiceNET includes all necessary


features to provide an effective voice evacuation
system. The Hochiki VoiceNET can be custom
configured to satisfy the needs of any high rise
application.
System Configuration:
Fire department authorities can easily take Basic System Includes:
command of evacuation or relocation procedures Master Panel (FNV-MP)
and emergencies. Building management and fire Master Mic Control
brigades can monitor and control emergency 16 switch control points
response even before the professionals arrive Dual Channel DMR
High speed communication loop
The VoiceNET system includes capacity for 6 Distributed Panel (FNV-DP)
channels of simultaneous audio. This provides for 4 Output Zones (may be configured for 8)
evacuation, stay-in-place, or other public address Dual Channel Audio Interface
announcements and automatic messages. Dual Channel Amplification
Optional
Fire Fighter Phones or Warden Stations may be Integrated Fire Phone
included as required. Area-of-Rescue stations can Area-of-Rescue
Number of distributed panels to be
reassure handicapped occupants that help is on Determined by building specifications
the way.
Maximum System Configuration
Up to 256 Distributed Panels (FNV-DP)
And up to 2028 monitor and control points

7051 Village Drive, Suite 100 Buena Park, CA 90621-2268 714.522.2246 www.hochiki.com
FNV-DP Voice Evacuation
Speaker Circuits
Distributed Panel
#18 AWG
F
I
R
E

F
I
R
E

F
I
R

Hochiki VoiceNET
E

F
I

True-Multiplex
R
E

TB1 TB1
TB2 TB2

#22 AWG Twisted Pair

System
TB3 TB3

Fire Phone

Fire Fire

Capabilities FNV-25/50/100 FNV-25/50/100


Phone Phone

NetComm Loop:
-Twisted Pair, Category 5
-4,000 Feet between panels
-50,000 Feet Total System Loop
-Data and 6 Audio Channels Simultaneously
-High Speed RS-485 Communications
-Style 4 or Style 7 Field Selectable

FNV-DP
Distributed Panel Voice Evacuation
Speaker Circuits

Head End Control F


I
R
E

F
FNV-MP I
R
E

Master Panel
F
I
R
E

PAGING F
CONTROL
I
R
E

TB1 TB1
TB2 TB2

TB3 TB3

Fire Phone

Fire Fire

FNV-25/50/100 FNV-25/50/100
Phone Phone

FIRE PHONE CONTROL


Hochiki VoiceNET
High Rise Multiplex
11 Floor Typical Riser Diagram

11th Floor S S
P
AR

S S
10th Floor
P
AR

S S
9th Floor CM FNV-DP
P
AR

S S
8th Floor
P
AR

S S
7th Floor
P
AR

S S
6th Floor
P
AR

S S
5th Floor CM FNV-DP
P
AR

S S
4th Floor
P
AR

S S
3rd Floor P
AR

RS 485
DATA LOOP S S
2nd Floor
P
AR

S S
1st Floor FNV-MP FNV-DP
P

S S
Basement
P

S Speaker, Speaker/Strobe AR Area of Rescue Station


P Fire Fighter Phone Jack

7051 Village Drive, Suite 100


Buena Park, CA 90621-2268
Engineering Specifications
Hochiki VoiceNET High Rise

The voice evacuation system shall be Hochiki Series VoiceNET FNV High Rise or approved
equal.

The VoiceNET FNV system shall include one Master Panel and one or more Distributed
Panels. The system shall be microprocessor based, and shall be compatible for use with
contact closures from the Fire Alarm Control Panel, (FACP). The system shall have a high-
speed communication bus and have the capacity for 6 channels of audio and data on a single
pair of wires. The field wiring for the communication bus may be configured for either Style "4"
or Style "7" supervision. The system shall have the capacity for Fire Fighters Phone, Area-of-
Rescue communication and also have the capacity for Fan & Damper control with monitored
feedback. The system shall have a minimum capacity of 2028 monitor and control points.

The Master Panel shall contain an integral microphone, dual channel digital message repeater,
(DMR) and digital tone generator, 120 VAC power supply, and battery charger. The system
shall be modular in design, and shall be expandable such that additional system control points
may be configured. The system shall include integral self-diagnostic routines that shall
continually monitor system status, and shall indicate the precise type of trouble conditions
should they occur in the system. A trouble condition within the system shall cause a trouble
indication to be transmitted to the FACP.

Distributed panels shall provide a minimum of 4 Class "B" speaker circuits, expandable to
sixteen total. Alternately, panel may be configured for 4 Class "A" speaker circuits, up to 8 total.
Panel may be configured for 1 to 8 amplifiers. Panel must provide up to 6 simultaneous audio
channels, up to 8 Fire Phone circuits, up to 4 Area of Refuge circuits and up to two
Control/Monitor loops. Amplifiers will contain their own power supplies, battery chargers and
provide auxiliary power for other components. Speaker circuits shall be supervised for short
and open circuit conditions, and shall be able to withstand transient or continuous short-circuit
conditions without damage to the system.

System may be configured for General Alarm All Call operation, Alarm by Zone or
Floor Above / Floor Below as required. Contact closures shall allow immediate broadcast of an
alarm signal and evacuation message to the appropriate area. Non-Alarm areas may receive
alert tones and messages as required or activated by the FACP.

The alarm signal/evacuation message shall be broadcast until the FACP is reset, or until
emergency personnel interrupt the broadcast with a manual page.

To prevent unauthorized tampering, the voice evacuation system shall disable the microphone
if the microphone is keyed continuously for 3 minutes or more. Systems that do not have this
feature shall not be acceptable.

Specifications are subject to change without notice. Specifications


are provided for information only and no responsibility is assumed
by Hochiki America, Inc. for their use.
Features:
True Multiplex 6 Channel Distributed Audio FNV-MP
Integrated Fire Phone, Area of Rescue High Rise Voice Evacuation System
and Fan & Damper Control capability
Modular System - components added as needed
Master Panel
Integrated 2 Channel Digital Message Repeater
Live Microphone Page to any zone SYSTEM
RESET

Fast RS-485 Communication Protocol PAGE


ALL-CALL

Fully Supervised FAULT


SILENCE PAGING
Easy Installation and Operation CONTROL

Natural Sound Voice Recordings


Built in Alarm and Alert Signals
Up to 4 Minute Message Capacity
Works with 12VDC or 24VDC Fire Alarm Panel
Works with Analog/Addressable and
Microprocessor based Fire Alarm Panels.
3 Minute Message Restart on Microphone Key
Made in the USA.

Description:

The Hochiki FNV High Rise Evacuation System


operates in conjunction with the Fire Alarm Control
Panel (FACP) in a building to provide automatic
response to life safety emergencies.

The Hochiki FNV includes all necessary features


to provide an effective voice evacuation system.
The Hochiki FNV can be custom configured to
satisfy the needs of any high rise application.

Fire department authorities can easily take


command of evacuation or relocation procedures System Configuration:
and emergencies. Building management and fire Basic System Includes:
brigades can monitor and control emergency
response even before the professionals arrive Master Panel (FNV-MP)
Master Mic Control
The FNV system includes capacity for 6 channels 16 Switch Control points
of simultaneous audio. This provides for Dual Channel DMR
evacuation, stay-in-place, or other public address High Speed communication loop
announcements and automatic messages.
Optional
Fire Fighter Phones or Warden Stations may be Integrated Master Fire Phone
included as required. Area-of-Rescue stations can
reassure handicapped occupants that help is on Area-of-Rescue
the way. Smoke control, stair pressurization, and Fan and Damper system control
HVAC shutdown can be completely automatic,
unless controlled manually by management or fire Maximum System Configuration
authorities.
Up to 1000 monitor and control points

LISTED

7051 Village Drive, Suite 100 Buena Park, CA 90621-2268 714.522.2246 www.hochiki.com
FNV MP64/P
Master Panel
Ribbon Cable Connection Detail

MMC

20 Pin Ribbon

1
2 J1
3
TB1
TB1 TB2

MFP P3 P5

SLC SLC P2 P2

2 1
DCC ASC
34 Pin Ribbon P4 P5
P1

P2

SLC SLC 10 Pin Ribbon P1


LED1 LED2 LED3
TB3 TB4 TB5 P3

4 3

34 Pin Ribbon
34 Pin Ribbon
SSC

1 2 3
1
TB2 2

TB3
M
F PWR-2A TB1 TB2
I I/O
Card
TB1
1 2 3 IOI

Components mounted to
back plate inside of cabinet.

Components mounted on hinged front panel.


Connectors shown are on the back of the
components.

In the Master Panel system components are mounted to a removable back plate. The door and front panel are
removable. This enables field wiring to be installed cleanly.

Connections to the User Interface components ( Switch/LED banks, Mic/System control and Master Fire Phone)
is accomplished with ribbon cables. The front panel mounts separately on a continuous hinge so once installed
the access for system programming is easily accommodated.
NetComm Loop Wiring (Style 4)
IN FROM LAST PANEL RETURN TO MASTER

OUT TO FIRST DISTRIBUTED PANEL IN FROM PREVIOUS PANEL

NetCom Bus
(Supervised)

*A - Optional wiring for


Style 7 supervision
1

P3
1
2 J1 P4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 2
3
J1
3
TB1 TB2 TB1 TB1 TB2 TB3 TB4 TB1 TB2

1 2 3 4
LED1

P5 P3
P3
TB5

P2

1 2 3 4
P1 P2 P2

TB6
MFP DCC ASC DCC

1 2 3 4
P5 P4
P4
P1
TB7

P2

MBR
LED1 LED2 LED3
LED1 LED2 LED3 P1 TB3 TB4 TB5
P1 TB3 TB4 TB5 P3 TB9

MASTER PANEL DISTRIBUTED PANEL

NetComm Loop Wiring (Style 7)

Redundant Communication Bus

Primary Communication Bus

P3
1
2 J1 P4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 2
3
J1
3
TB1 TB2 TB1 TB1 TB2 TB3 TB4 TB1 TB2
1 2 3 4

LED1

P5 P3
P3
TB5

P2
1 2 3 4

P1 P2 P2

TB6
MFP DCC ASC DCC
1 2 3 4

P5 P4
P4
P1
TB7

P2

MBR
LED1 LED2 LED3
LED1 LED2 LED3 P1 TB3 TB4 TB5
P1 TB3 TB4 TB5 P3 TB9

MASTER PANEL DISTRIBUTED PANEL

The redundant loop must be run in separate conduit


with minimum spacing from the primary. Check local
code requirements.
Master Panel Configurations:

FNV-MP16 Master Panel, 16 Switch Control


FNV-MP32 Master Panel, 32 Switch Control
FNV-MP48 Master Panel, 48 Switch Control
FNV-MP64 Master Panel, 64 Switch Control
FNV-MP80 Master Panel, 80 Switch Control
FNV-MP96 Master Panel, 96 Switch Control

FNV-MP16/P Master Panel, 16 Switch Control, Master Fire Phone


FNV-MP32/P Master Panel, 32 Switch Control, Master Fire Phone
FNV-MP48/P Master Panel, 48 Switch Control, Master Fire Phone
FNV-MP64/P Master Panel, 64 Switch Control, Master Fire Phone
FNV-MP80/P Master Panel, 80 Switch Control, Master Fire Phone
FNV-MP96/P Master Panel, 96 Switch Control, Master Fire Phone

Panel Options: Cards may be added as job requirements demand

FNV-MFP Master Fire Phone Enables system to incorporate 2 way communication.


Included with /P panels.

FNV-SSC Switch Scan Card Included in basic panels, up to 7 additional cards may be
added.
FNV-SLC Switch LED Card 16 Switch LED Bank, up to 8 per FNV-SSC.

FNV-IOI Input Interface Card One included with basic panel, additional cards give 16 control

Technical Characteristics:

Primary Power: 120 VAC


24 VDC Battery Power
Communications Bus: RS-485 Standard,
Electrical Ratings:All Circuits @ 24VDC.
1M Baud data rate, Category 5 cable.

Master Panel Voltage: 5V peak-to-peak max.


Current: 50mA max.
Standby Alarm Impedance: 120 Ohms
DCC 80 mA 80 mA (max. imp. between panels)
ASC 30 mA 30 mA Frequency: 1.024MHz
MFP 10 mA 10 mA
SSC 25 mA 25 mA Backbox Dim: 14.5 x 27 x 4 whd
SLC 6 mA 6 mA Color: Charcoal Greystandard
MMC 45 mA 45 mA Redoptional
IOI 20 mA 20 mA

Specifications are subject to change without notice. Specifications


are provided for information only and no responsibility is assumed
by Hochiki America, Inc. for their use.
Features:
True Multiplex 6 Channel Distributed Audio FNV-DP
Integrated Fire Phone, Area of Rescue High Rise Voice Evacuation System
and Fan & Damper Control capability Distributed Panel
Modular System - components added as needed
Integrated 2 Channel Digital Message Repeater
Live Microphone Page to any zone
Fast RS-485 Communication Protocol
Fully Supervised
Easy Installation and Operation 1 2 3 4
TB1
1 2 3 4
TB2
1 2 3 4
TB3
1 2 3 4
TB4
1
2
3
J1
TB1 TB2

Natural Sound Voice Recordings

1 2 3 4
TB5 P3

Built in Alarm and Alert Signals

1 2 3 4
P2

TB6
DCC
Up to 4 Minute Message Capacity DCC

1 2 3 4
P4

TB7

Works with 12VDC or 24VDC Fire Alarm Panel 1

MBK
8 B

AMI
Works with Analog/Addressable and TB8
MBR
P1

Microprocessor based Fire Alarm Panels. 4 A

3 Minute Message Restart on Microphone Key TB1 TB1

Made in the USA.


1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8

TB2 11 TB2 11
J1 10 J1 10
9 9
8 8
1 TB3 7 1 TB3 7
2 6 2 6
3 J2 5 3 J2 5
4 4 4 4
5 YEL FAULT 1 2 3 3 5 YEL FAULT 1 2 3 3
6 2 6 2
7 GRN NORMAL 1 7 GRN NORMAL 1
8 8
RED ALARM RED ALARM

P2 P2
MESSAGE MIC MESSAGE MIC
GAIN GAIN GAIN GAIN

Description: FNV-25E FNV-25E

SN1 SN1

The Hochiki FNV High Rise Evacuation System


S1 S1

operates in conjunction with the Fire Alarm Control


Panel (FACP) in a building to provide automatic
response to life safety emergencies.

The Hochiki FNV includes all necessary features


to provide an effective voice evacuation system.
The Hochiki FNV can be custom configured to
satisfy the needs of any high rise application.
System Configuration:
Fire department authorities can easily take
Basic System Includes:
command of evacuation or relocation procedures
and emergencies. Building management and fire Distributed Panel (FNV-DP)
brigades can monitor and control emergency 4 Output Zones (may be configured for 8)
response even before the professionals arrive Dual Channel Audio Interface
Dual/Single Channel Amplification
The FNV system includes capacity for 6 channels
of simultaneous audio. This provides for Amplifier Options:
evacuation, stay-in-place, or other public address 25 / 50 / 100W Dual Channel
announcements and automatic messages. 25 / 50 / 100 / 200W Single Channel

Fire Fighter Phones or Warden Stations may be Optional


included as required. Area-of-Rescue stations can Integrated Fire Phone
reassure handicapped occupants that help is on 4 Circuits expandable to 8 or 12
the way. Smoke control, stair pressurization, and
HVAC shutdown can be completely automatic, Area-of-Rescue
unless controlled manually by management or fire Fan and Damper system control
authorities.
Maximum System Configuration
LISTED Up to 256 Distributed Panels (FNV-DP)

7051 Village Drive, Suite 100 Buena Park, CA 90621-2268 714.522.2246 www.hochiki.com
FNV
Distributed Panel
Connection Detail

10K
EOLR
Speaker Circuits

SEE FIG. 2 FOR FPI TO MBR CONNECTION DETAIL


1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 SEE FIG. 3 FOR AMI TO AMPLIFIER CONNECTION DETAIL
P10
MBK
Fire Phone Circuits

1 2 3 4

AMI
FPI
1 2 3 4

P14

10K
EOLR
1 2 3 4

P15

P3 P2 P1
DCC

MBR
TB3
TB8
P1 1234

TB9 TB11

Set EOLR

TB1 TB1
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8

TB2 11 TB2 11
J1 10 J1 10
9 9
8 8
1 TB3 7 1 TB3 7
2 6 2 6
3 J2 5 3 J2 5
4 4 4 4
5 YEL FAULT 1 2 3 3 5 YEL FAULT 1 2 3 3
6 2 6 2
7 GRN NORMAL 1 7 GRN NORMAL 1
8 8
RED ALARM RED ALARM

P2 P2
MESSAGE MIC MESSAGE MIC
GAIN GAIN GAIN GAIN

FNV-25E FNV-25E

10 PIN RIBBON 10 PIN RIBBON

SN1 SN1
S1 S1
FPI to MBR Connection AMI to Amplifier Connection
To left side
Amplifier
To right side
10 PIN RIBBON Amplifier

TO MBR J7 10 PIN RIBBONS

MBR J7

This side plugs


into MBR, 2nd
slot on right

FPI Each AMI card provides audio


This side plugs
into MBR, 1st channels and control to two
slot on right
amplifier modules or amplifier
AMI banks. Maximum configuration
Each FNV-DP panel may is 5 AMI cards in each FNV-DP.
(Additional modules would mount in
have up to 4 FPI cards for separate cabinets)
a max. of 16 phone circuits.
(Additional FPI cards require
an FNV-FPO for circuit termination)

Eight Class B Speaker Lines


E
O
L 1
F F
EOLR
I I
R R
E E

E
O
L 2 Eight Class "B" may
F
I
F
I
EOLR also be configured
R
E
R
E as 4 A / B circuits

E
O
L 8
1 2 3 4 5 6 7 8 F F
EOLR
I I
R R
E E

Standard Life Safety Speakers,


Strobes connected and powered separately
1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
TB1 TB2 TB3 TB4
Four Class A Speaker Lines
1 2 3 4

F F
I I
TB5 R
E
R
E
1 2 3 4

TB6
1 2 3 4

F F
I I
R R
E E
TB7
1 EOL
2 3 4 EOL
MBK#2
MBK#1

AMI

1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
MBR TB1 TB2 TB3 TB4
1 2 3 4

TB8 TB5

Second FNV-MBK card provides


additional speaker circuits
May be configured as several options
Distributed Panel Configurations:

FNV-DPS25 Distributed Panel, Single Channel, 25W


FNV-DPS50 Distributed Panel, Single Channel, 50W
FNV-DPS100 Distributed Panel, Single Channel, 100W

FNV-DPS25/P Distributed Panel, Single Channel, 25W, Fire Phone


FNV-DPS50/P Distributed Panel, Single Channel, 50W, Fire Phone
FNV-DPS100/P Distributed Panel, Single Channel, 100W, Fire Phone

FNV-DP25 Distributed Panel, Dual Channel, 25W


FNV-DP50 Distributed Panel, Dual Channel, 50W
FNV-DP100 Distributed Panel, Dual Channel, 100W

FNV-DP25/P Distributed Panel, Dual Channel, 25W, Fire Phone


FNV-DP50/P Distributed Panel, Dual Channel, 50W, Fire Phone
FNV-DP100/P Distributed Panel, Dual Channel, 100W, Fire Phone

Panel Options: Cards may be added as job requirements demand

FNV-MBK Motherboard Relay Card Expands MBR output 8 Class B or 4 Class A speaker circuits

FNV-FPI Fire Phone Interface Card Included in /P panels, up to 3 additional cards may be added
FNV-FPO Fire Phone Output Card Used with additional FNV-FPIs for termination

FNV-AMI Audio Module Interface Card Included with basic panel, additional cards give the ability to control
multiple modules or accommodate full 3 channel operation

Technical Characteristics:

Primary Power: 120 VAC


24 VDC Battery Power
Electrical Ratings: All Circuits @ 24VDC. Communications Bus: RS-485 Standard,
1M Baud data rate, Category 5 cable.
Distributed Panel Voltage: 5V peak-to-peak max.
Standby Alarm Current: 50mA max.
DCC 55 mA 55 mA Impedance: 120 Ohms
MBR 10 mA 55 mA (max. imp. between panels)
AMI 10 mA 10 mA Frequency: 1.024MHz
FPI 13 mA 13 mA

Battery Charging: Maximum charging current from Backbox Dim: 14.5 x 27 x 4 whd
FNV-25/50 is 800mA. Maximum battery size is 17AHr. Color: Charcoal Greystd Redoptional
FNV-100 Maximum battery size is 24AHr.

Specifications are subject to change without notice. Specifications


are provided for information only and no responsibility is assumed
by Hochiki America, Inc. for their use.
Description:
Fire Phone accessories give the FNV system two
VoiceNet
way communication capability. Fire Phone Equipment
Fire Phone jacks are mounted on a single gang plate.

Fixed telephone and warden stations are available in


Surface/Semi-Flush mount cabinet with a Thumb
Turn latch

FNV-FJ

Ordering Information:
Model Number Description

FNV-FJ Telephone Jack FNV-FH


Brushed Stainless Steel Single Gang
Plate

FNV-FH Portable Handset


Color - Red
(6 mount in FNV-TC cabinet)

FNV-TC Telephone Cabinet


Holds 6 FNV-FH Portable Handset
Cabinet: Charcoal Gray - std. -R Red
(Surface/Semi-Flush Mount / Key Lock
27 x 14-1/2 x 4 h-w-d)

FNV-FS Fire Phone Station


Coil cord / Thumb Turn Latch FNV-FS
Cabinet: Red FNV-TC
(Surface/Semi-Flush Mount
(Shown with 6 FNV-FH) FNV-WS
12-3/4 x 7-1/4 x 3-3/4 h-w-d)

FNV-WS Warden Station


Armored cable / Thumb Turn Latch
Cabinet: Red
(Surface/Semi-Flush Mount
12-3/4 x 7-1/4 x 3-3/4 h-w-d)

LISTED

7051 Village Drive, Suite 100 Buena Park, CA 90621-2268 714.522.2246 www.hochiki.com
10K 1/2W
EOLR

Fire Phone Fire Phone


Handset Handset
Jack Jack

10K 1/2W
EOLR

Fire Phone Fire Phone


Handset Handset
Jack Jack

10K 1/2W
EOLR

Fire Phone Fire Phone


Handset Handset
Jack Jack

All Fire Phone


Circuits use
Twisted Pair 10K 1/2W
/

EOLR
#22 AWG min.
Fire Phone Fire Phone
Handset Handset
Jack Jack

10K 1/2W
EOLR

To Additional Fire Phone Fire Phone


Handset Handset

Fire Phone Circuits Jack Jack

(not shown)

1 2 3 4 1 2 3 4 1 2 3 4 1 2
TB1 TB2 TB3 TB
1 2 3 4

TB5
1 2 3 4

TB6
FPO Fire
1 2 3 4

Phone TB7
Loops
(Supervised)

MBR
/
10 Pin Ribbon Cable FPI
Cards plug into slots
available on MBR
First FPI allows 4 Fire Phone
Circuits off of MBR. Adding 2nd
FPI and an FPO allows 4
additional Fire Phone Circuits
(16 circuits max. in any FNV-DP)

7051 Village Drive, Suite 100


Buena Park, CA 90621-2268

You might also like