You are on page 1of 2

APT 300 GROUT GC XI MNG CHO NG GEN CP D NG LC

KHNG TCH NC KHNG CHA CT

M T Tip tc khuy cho ti khi t c chy ti


APT 300 l grout (va lng) gc xi mng khng u.
co ngt, khng cha clorua v khng tch nc Lu : i) Lng nc trn c th ph thuc vo
ngay c khi chy cao. tc trn, tc trn cao th lng nc trn
Thch hp cho bm va ng gen c phng thp i; ii) Khng kin ngh trn tay hoc s dng
ng hay nm ngang cho kt cu d ng lc. my trn tc thp. Tuy nhin khi s dng my/
APT 300 c ph gia chng co ngt v ph gia que trn tc thp, lng nc trn th vo
siu do gip ngn cn co ngt c trng thi khong 45% theo khi lng vi thi gian trn
do v cng. lu hn (khong 5 pht hoc ti khi t ng
TNH NNG K THUT u).
- Bt mu xm/xi mng; - Bm phi cho m bo rng grout chn lp y
- chy (cn chy ASTM C939): 15 - 30 giy ng gen v bao quanh tao hoc cp.
- Cng nn: Nn tin hnh th ti cng trng trc m
o 21 MPa 7 ngy tui bo rng bin php v thit b thi cng t c
o 35 MPa 28 ngy tui kt qu ra.
- Thi gian ng kt (ASTM C953): 6-12 gi - Grout trn phi c s dng trong vng 60
- Thay i th tch (ASTM C1090): pht k t khi trn.
o 0.0%-0.1% 24 gi - Ty b ton APT 300 cha cng khi dng c v
o 0.2% 28 ngy. thit b s dng bng nc. Vi grout cng
- Tch nc (ASTM C940): 0% sau 4 gi; phi s dng c hc ty b.
- Dung trng t (ASTM C138): 1900-2000 - i vi cng tc ly mu: i) Khun phi c tram
Kg/m3; kn ngn grout b r i; ii) Mu phi c ph
- thm (ASTM C1202): <2500 couloms sau 6 bng nilon trnh bay hi nc qu nhanh.
gi. PACKAGE
- Hm lng clorua : <0.005% theo dung trng xi - APT 300 ng trong bao 25kg.
mng s dng. - Thi gian s dng: 6 thng trong iu kin kh
- Florua, sun-phua, nitrat: Khng c. ro v khng m cng nh l kn kht.
- Khng c ct gip tng kh nng lp y l rng, AN TON, SC KHE, MI TRNG
hng trong lng kt cu s dng. - APT 300 c bn cht kim.
NG DNG - Trnh tip xc trc tip vi mt.
- Dng cho ng gen, l h, u vo, l rt cho kt - S dng gang tang v bo v mt trong khi thi
cu d ng lc. cng.
- S dng cho khng gian cht hp ti grout c - Khi tip xc vi da, cn ra sch vi nc.
ct kh chy lp y. DISCLAIM
- ng gen, l m, l rt, ca rt cn phi c lm Cc thng tin, bao gm nhng khng hn ch, hng dn lin
quan ti thi cng v s dng cui cng sn phm APT 300 c
sch khi bi bn, tp vt, du m, du ha v
cung cp l thin ch ca chng ti da trn kinh nghim v hiu
bt k cht gy hi no trong khi thi cng. bit hin ti v iu kin lu tr ng cch, thi cng v s dng
- 35-42.5 nc theo trng lng hn hp vo trong iu kin c bnh thng nh nu trn. Trong iu kin
thng trn hoc thng cha. Lng nc chnh thi cng thc t, chng ti khng m bo vic s dng sn
xc cn phi c xc nh trc khi s dng. phm cho mt mc ch c th no m c s khc bit v vt
- grout vo lng nc sn. Kin ngh s t, ct liu hay iu kin thi cng cng nh khng c mt rng
buc php l no i vi chng ti hm t cc thng tin ny
dng my trn tc cao 1800 vng/pht (rpm) hoc t mt hng dn bng vn bn hay bt k s t vn no.
hoc cao hn c cnh trn ct cnh (gim lc ct Ngi s dng sn phm ny phi th nghim nhm m bo
vt liu). rng sn phm c s dng l ph hp vi mc ch cn. n
- Trn trong khong 3 pht tnh t lc t sau v sn xut sn phm c th thay i thng tin sn phm mnh.
cng hoc cho ti khi hn hp t c ng
nht.
MI CHI TIT XIN LIN H: CNG TY TNHH A&P PLUS
a ch: S nh 6B, l 11, khu tp th cng ty ng b 230 - C Bi - Gia Lm - H Ni.
Cellphone: 0964.827.294 Email: Info@anpplus.com Website:anpplus.com
APT 300 ZERO BLEED, SAND FREE, CEMENTITIOUS GROUT FOR
POST-TENSIONED STRUCTURES

DESCRIPTIONS Continue agitating the grout in the container to


APT 300 is a non-shrink, cementitious grout achieve optimum flow.
containing no chloride and does not bleed even Note: i) Water content can be dependent on speed of
at high flow. mixing, higher the rpm is the lower water content is; ii)
Hand mix or low rotation rate are not recommended.
Use for horizontal and vertical grouting of ducts However for low rotation strirrer, water content is about
within bonded, post-tensioned structures. 45% by weight with longer mixing time (5 minutes or more
APT 300 consists of anti-shrinkage and to get homogeneous).
superplastizing agents, which prevents - Grout is so pumped that it ensures complete
shrinkage in both plastic and hardened states. filling of the ducts and complete surroundings of
SPECIFICATIONS the strands or bar.
- Grey/cement powder; A mock-up on site is recommended to ensure
- Flowability (flow cone ASTM C939): 15 - 30 that the placement means and methods yield the
seconds specified results.
- Compressive strength: - Mixed grout must be placed within 60 minutes
o 21 MPa at 7 days of mixing.
o 35 MPa at 28 days - Remove uncured APT 300 from tools and
- Setting time (ASTM C953): 6hrs - 12hrs equipment with water. Hardened grout can only
- Volume change (ASTM C1090): be removed mechanically.
o 0.0%-0.1% at 24hrs - For sampling: i) molds shall be sealed off to
o 0.2% at 28 days prevent grout from leaking; ii) specimens shall be
- Bleeding (ASTM C940): 0% after 4 hours; covered with plastic/nylon sheets to avoid quick
- Wet density (ASTM C138): 1900-2000 Kg/m3; evaporation.
- Permeability (ASTM C1202): <2500 couloms PACKAGE
after 6hrs - APT 300 is packaged in 25kg bag.
- Chlorides content : <0.005% of density of - Shelf life: six months in dry and unopened
cement used. condition.
- Fluorides, sulphites, nitrates: none. HEALTH, SAFETY AND ENVIROMENT
- Sand-free allows fillings into cavities and voids - APT 300 has alkali nature.
within the applied structure. - Avoid contact with skin and eyes.
APPLICATION - Wear protective gloves and eye protection
- Use for ducts, openings, inlets and outlets within during application.
bonded, post-tensioned structures. - If skin contact occurs, wash skin thoroughly.
- Use for tight spaces where grouts containing DISCLAIM
sand is difficult to flow. All information furnished for this product including but not limited
to, any recommendation and advice with respect to the application
- Ducts, openings, inlets and outlets are clean, free
and utilization is provided in good faith based on A&P PLUS
of dirt and debris, oils, kerosene and any other current experience and knowledge of the product when properly
contaminants at all times. stored, handled and applied under normal conditions in line with
- Introduce 35-42.5% water by weight of grout to instructions. In practice, the differences in materials, substrates,
the mixer or container. Exact water content shall storage and handling conditions, actual site conditions and other
be verified before using. factors out of A&P PLUSs control are such that A&P PLUS assumes
- Add grout to the introduced water. It is completely no liability for the provision of such information, advice,
recommended to mix grout by mixer or stir with recommendations or instructions related to its products, nor shall
rotation per minute of 1800 rpm and higher with any legal relationship be created by or arise from the provision of
shear-cutting blades. such information, advice, recommendations or instructions related
to its products. The user must test the product for suitability for
- Mix approximate 3 minutes after the addition of
the intended application and purpose before proceeding with the
the last bag or until a homogeneous mix is full application of the product. A&P PLUS reserves the right to
achieved. change the properties of its products without notice.

FOR MORE INFORMATION PLEASE CONTACT: A&P PLUS CO Ltd;


Add: Number 6B, lot 11, 230-roadway tenement Co Bi commune Gia Lam district Hanoi
Cellphone: 0964.827.294 Email: Info@anpplus.com Website:anpplus.com