You are on page 1of 34

Reinforced Concrete Design

Using the Ultimate Limit Design Method


according to the ECP 203-2007

Ver. 8.0

Please send your comments & suggestions to improve this tool on


melkateb@hotmail.com

by
Eng. Mahmoud M. El-Kateb, M.Sc.

Structural Engineering Dept.


Faculty of Engineering - Ain Shams University
Concrete design according to ECP 203-2007

* Calculation of Coeffecients

* Project :

Hollow Slabs:

Web breadth Spacing Thick Slab th F.C L.L One way Two way
Area
b (cm) e (cm) t (cm) ts (cm) (kg/m2) (kg/m2) Wu (t/m`) Wu (t/m2)
1 12 40 32 7 150 200 1.237 1.385
2 12 40 27 7 150 200 1.129 1.250
3 12 40 30 5 150 200 1.169 1.318
4 12 40 32 7 150 200 1.237 1.385
5 12 40 32 7 150 200 1.237 1.385

Slabs:

Long span Short span Code of practice Marcus Grashoff


Area
Span (m) contin. Span (m) contin. a b a b a b
1 4.58 1 4.2 1 0.395 0.294 0.469 0.331 0.586 0.414
2 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
3 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
4 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
5 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
6 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
7 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
8 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
9 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
10 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291

Beams:

Load on Long Short Load coeff. Load distribution for


Area
slab (t/m2) span (m) span (m) shear moment shear (t/m`) moment (t/m`)
1 0.85 5 4 0.600 0.787 1.020 1.337
2 0.85 5 4 0.600 0.787 1.020 1.337
3 0.85 5 4 0.600 0.787 1.020 1.337
4 0.85 5 4 0.600 0.787 1.020 1.337
5 0.85 5 4 0.600 0.787 1.020 1.337
6 0.85 5 4 0.600 0.787 1.020 1.337
7 0.85 5 4 0.600 0.787 1.020 1.337
8 0.85 5 4 0.600 0.787 1.020 1.337
9 0.85 5 4 0.600 0.787 1.020 1.337
10 0.85 5 4 0.600 0.787 1.020 1.337

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Slabs

* Project :

Concrete Fcu = 300 kg/cm2


Steel Fy = 4000 kg/cm2

Ult. Moment Breadth Depth As Asmin Used


Sec. C1 J Rft. /m Notes
Mu (m.t) b (cm) d (cm) (cm ) (cm2)
2
As
1 4 100 18 4.930 0.826 6.73 2.70 6.73 6 f 12 safe
2 5 100 27 6.614 0.826 5.46 4.05 5.46 5 f 12 safe
3 12 100 35 5.534 0.826 10.24 5.25 10.24 6 f 16 safe
4 18.5 100 35 4.457 0.818 16.16 5.25 16.16 9 f 16 safe
5 22 100 35 4.087 0.807 19.47 5.25 19.47 18 f 12 safe
6 34 100 35 3.288 0.768 31.62 5.25 31.62 28 f 12 safe
7 3.5 100 20 5.855 0.826 5.20 3.00 5.20 5 f 12 safe
8 4.5 100 20 5.164 0.826 6.76 3.00 6.76 6 f 12 safe
9 5.5 100 20 4.671 0.823 8.36 3.00 8.36 8 f 12 safe
10 6.5 100 20 4.297 0.814 9.99 3.00 9.99 9 f 12 safe
11 8.5 100 20 3.757 0.795 13.37 3.00 13.37 12 f 12 safe
12 9.5 100 20 3.554 0.785 15.14 3.00 15.14 14 f 12 safe
13 10.5 100 20 3.381 0.774 16.95 3.00 16.95 15 f 12 safe
14 3.5 100 23 6.734 0.826 4.49 3.45 4.49 4 f 12 safe
15 4.5 100 23 5.939 0.826 5.81 3.45 5.81 6 f 12 safe
16 5.5 100 23 5.372 0.826 7.16 3.45 7.16 7 f 12 safe
17 6.5 100 23 4.941 0.826 8.53 3.45 8.53 8 f 12 safe
18 8.5 100 23 4.321 0.814 11.35 3.45 11.35 11 f 12 safe
19 9.5 100 23 4.087 0.807 12.79 3.45 12.79 12 f 12 safe
20 10.5 100 23 3.888 0.800 14.27 3.45 14.27 13 f 12 safe
21 11.5 100 23 3.715 0.793 15.77 3.45 15.77 14 f 12 safe
22 12.5 100 23 3.563 0.785 17.31 3.45 17.31 16 f 12 safe
23 13.5 100 23 3.429 0.777 18.88 3.45 18.88 17 f 12 safe
24 14.5 100 23 3.308 0.769 20.48 3.45 20.48 19 f 12 safe
25 -2 100 12 ### ### ### 1.80 ### ### f 12 ###
26 - 100 12 ### ### ### 1.80 ### ### f 12 ###
27 - 100 12 ### ### ### 1.80 ### ### f 12 ###
28 - 100 12 ### ### ### 1.80 ### ### f 12 ###
29 - 100 12 ### ### ### 1.80 ### ### f 12 ###
30 - 100 12 ### ### ### 1.80 ### ### f 12 ###
31 - 100 12 ### ### ### 1.80 ### ### f 12 ###
32 - 100 12 ### ### ### 1.80 ### ### f 12 ###

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Slabs

* Project :

Concrete Fcu = 300 kg/cm2


Steel Fy = 4000 kg/cm2

Ult. Moment Breadth Depth As Asmin Used


Sec. C1 J Rft. /m Notes
Mu (m.t) b (cm) d (cm) (cm ) (cm2)
2
As
33 - 100 12 ### ### ### 1.80 ### ### f 12 ###
34 #VALUE! 100 12 ### ### ### 1.80 ### ### f 12 ###

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Flat Slab

* Project :

Concrete Fcu = 250 kg/cm2


Steel Fy = 3600 kg/cm2

Module: Long direction 7 m Short direc. 6 m


Marginal beams: 1)Yes 2)No 2
Column dim.: Long direction 50 cm Short direc. 50 cm
Slab thickness: 22 cm
Live load: 400 kg/m2 Floor cover + Walls: 200 kg/m2
Slab load Wsu = 1.69 t/m2

Long direction 14.08 1 28.17 3


Column strip 4 16.90 2 14.08

Long direction 2.82 5 11.27 7


Field strip 8 11.27 6 8.45

Short direction 11.53 9 22.39 11 Modified


Column strip 12 12.89 10 10.85

Short direction 2.71 13 10.85 15 Modified


Field strip 16 10.85 14 8.14

Ult. Moment Breadth Depth As Asmin Used


Sec. C1 J Rft. /m Notes
Mu (m.t) b (cm) d (cm) (cm ) (cm2)
2
As
1 16.90 300 19 4.003 0.804 10.24 3.17 10.24 6 f 16 safe
2 28.17 300 19 3.100 0.753 18.23 3.17 18.23 10 f 16 safe
3 14.08 300 19 4.385 0.816 8.41 3.17 8.41 5 f 16 safe
4 14.08 300 19 4.385 0.816 8.41 3.17 8.41 5 f 16 safe
5 11.27 300 19 4.902 0.826 6.65 3.17 6.65 6 f 12 safe
6 11.27 300 19 4.902 0.826 6.65 3.17 6.65 6 f 12 safe
7 8.45 300 19 5.661 0.826 4.99 3.17 4.99 5 f 12 safe
8 2.82 300 19 9.804 0.826 1.66 3.17 3.17 2 f 12 safe
9 12.89 300 19 4.583 0.821 7.65 3.17 7.65 7 f 12 safe
10 22.39 300 19 3.478 0.780 13.98 3.17 13.98 13 f 12 safe
11 10.85 300 19 4.995 0.826 6.40 3.17 6.40 6 f 12 safe
12 11.53 300 19 4.845 0.826 6.80 3.17 6.80 7 f 12 safe
13 10.85 400 19 5.767 0.826 4.80 3.17 4.80 5 f 12 safe
14 10.85 400 19 5.767 0.826 4.80 3.17 4.80 5 f 12 safe

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

15 8.14 400 19 6.659 0.826 3.60 3.17 3.60 4 f 12 safe


16 2.71 400 19 11.534 0.826 1.20 3.17 3.17 2 f 12 safe

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Check punching in flat slab columns

* Project :

Concrete Fcu = 300 kg/cm2

Internal columns:

Ult. Load Col. Dims. Slab qcpu qpu


Col. Notes
Nu (ton) b (cm) t (cm) Thick (cm) (kg/cm ) 2
(kg/cm2)
1 77 50 70 22 14.14 13.84 Safe
2 60 30 60 25 14.14 11.03 Safe
3 60 30 60 25 14.14 11.03 Safe

Ult. Load Col. Dims. Slab qpu qpu


Col. Notes
Nu (ton) D (cm) Thick (cm) (kg/cm ) 2
(kg/cm2)
1 50 40 25 14.14 12.63 Safe
2 50 40 25 14.14 12.63 Safe
3 50 40 25 14.14 12.63 Safe

Edge columns:
t
Ult. Load Col. Dims. Slab qcpu qpu
Col. Notes
Nu (ton) b (cm) t (cm) Thick (cm) (kg/cm2) (kg/cm2)
1 30 30 60 25 14.14 10.21 Safe
2 30 30 60 25 14.14 10.21 Safe
3 30 30 60 25 14.14 10.21 Safe

t
Corner columns:

Ult. Load Col. Dims. Slab qcpu qpu


Col. Notes
Nu (ton) b (cm) t (cm) Thick (cm) (kg/cm ) 2
(kg/cm2)
1 20 30 60 25 14.14 11.54 Safe

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

2 20 30 60 25 14.14 11.54 Safe


3 20 30 60 25 14.14 11.54 Safe

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Beams

* Project :

Concrete Fcu = 300 kg/cm2


Steel Fy = 4000 kg/cm2

Ult. Moment Breadth Comp.fl. Depth Asmin Used


Sec. C1 J Rft. Notes
Mu (m.t) b (cm) B (cm) d (cm) (cm2) As
1 11 12 12 65 3.719 0.793 2.15 5.34 3 f 16 safe
###
2 0 30 30 140 #DIV/0! #DIV/0! #DIV/0! ### ### f 22 #DIV/0!
###
3 0 25 25 65 #DIV/0! #DIV/0! #DIV/0! ### ### f 16 #DIV/0!
###
4 0 30 30 65 #DIV/0! #DIV/0! #DIV/0! ### ### f 16 #DIV/0!
###
5 0 25 25 65 #DIV/0! #DIV/0! #DIV/0! ### ### f 16 #DIV/0!
###
6 0 25 25 65 #DIV/0! #DIV/0! #DIV/0! ### ### f 16 #DIV/0!
###
7 10 25 25 65 5.629 0.826 4.47 4.66 3 f 16 safe
###
8 11 25 25 65 5.367 0.826 4.47 5.12 3 f 16 safe
###
9 12 25 25 65 5.139 0.826 4.47 5.59 3 f 16 safe
###
10 13 25 25 65 4.937 0.826 4.47 6.05 4 f 16 safe
###
11 14 25 25 65 4.758 0.825 4.47 6.53 4 f 16 safe
###
12 15 25 25 65 4.596 0.821 4.47 7.03 4 f 16 safe
###
13 16 25 25 65 4.450 0.818 4.47 7.53 4 f 16 safe
###
14 17 25 25 65 4.317 0.814 4.47 8.03 4 f 16 safe
###
15 18 25 25 65 4.196 0.811 4.47 8.54 5 f 16 safe
###
16 19 25 25 65 4.084 0.807 4.47 9.05 5 f 16 safe
###
17 20 25 25 65 3.980 0.804 4.47 9.57 5 f 16 safe
###
18 21 25 25 65 3.884 0.800 4.47 10.10 6 f 16 safe
###
19 22 25 25 65 3.795 0.796 4.47 10.63 6 f 16 safe
###
20 23 25 25 65 3.712 0.792 4.47 11.16 6 f 16 safe
###
21 24 25 25 65 3.634 0.789 4.47 11.70 6 f 16 safe
###
22 25 25 25 65 3.560 0.785 4.47 12.25 7 f 16 safe
###
23 26 25 25 65 3.491 0.781 4.47 12.80 7 f 16 safe
###
24 27 25 25 65 3.426 0.777 4.47 13.36 7 f 16 safe
###
25 28 25 25 65 3.364 0.773 4.47 13.93 7 f 16 safe
###
26 29 25 25 65 3.306 0.769 4.47 14.50 8 f 16 safe
###
27 30 25 25 65 3.250 0.765 4.47 15.08 8 f 16 safe
###
28 31 25 25 65 3.197 0.761 4.47 15.66 8 f 16 safe
###
29 32 25 25 65 3.147 0.757 4.47 16.26 9 f 16 safe
###
30 33 25 25 65 3.099 0.753 4.47 16.86 9 f 16 safe
###
31 34 25 25 65 3.053 0.749 4.47 17.47 9 f 16 safe
###
32 35 25 25 65 3.009 0.744 4.47 18.08 9 f 16 safe
###

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Beams

* Project :

Concrete Fcu = 300 kg/cm2


Steel Fy = 4000 kg/cm2

Ult. Moment Breadth Comp.fl. Depth Asmin Used


Sec. C1 J Rft. Notes
Mu (m.t) b (cm) B (cm) d (cm) (cm2) As
33 36 25 25 65 2.967 0.740 4.47 18.71 10 f 16 safe
###
34 15 25 25 65 4.596 0.821 4.47 7.03 4 f 16 safe
###

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Beams with Compression Rft.

* Project :

Concrete Fcu = 250 kg/cm2


Steel Fy = 3600 kg/cm2

Ult. Moment Breadth Depth Thick Main Comp.


Sec. Main Rft. Comp. Rft. Notes
Mu (m.t) b (cm) d (cm) t (cm) As As
1 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
2 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
3 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
4 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
5 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
6 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
7 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
8 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
9 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
10 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
11 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
12 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
13 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
14 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
15 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
16 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
17 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
18 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
19 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
20 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
21 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
22 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
23 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
24 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
25 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
26 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
27 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
28 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
29 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
30 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
31 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
32 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

33 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok
34 40 25 65 70 23.43 7 f 22 3.11 3 f 12 ok

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Sec. under M,N

* Project :

Concrete Fcu = 250 kg/cm2


Steel Fy = 3600 kg/cm2

Ult. Moment Normal Breadth Depth Thick Asmin Used


Sec. ecc. C1 J Rft.
Mu (m.t) Nu (t) b (cm) d (cm) t (cm) (cm2) As
1 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
2 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
3 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
4 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
5 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
6 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
7 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
8 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
9 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
10 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
11 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
12 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
13 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
14 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
15 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
16 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
17 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
18 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
19 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
20 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
21 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
22 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
23 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
24 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
25 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
26 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
27 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
28 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
29 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
30 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
31 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
32 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Sec. under M,N

* Project :

Concrete Fcu = 250 kg/cm2


Steel Fy = 3600 kg/cm2

Ult. Moment Normal Breadth Depth Thick Asmin Used


Sec. ecc. C1 J Rft.
Mu (m.t) Nu (t) b (cm) d (cm) t (cm) (cm2) As
33 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16
34 15 -20 25 65 70 Big 3.546 0.784 4.97 5.06 3 f 16

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Check shear in beams

* Project :

Concrete Fcu = 300 kg/cm2


Concrete qall = 10.73 kg/cm2
Stirrups Fy = 4000 kg/cm2

Ult. Shear Breadth Depth qu As no. of


Sec. Stirrups Notes
Qu (ton) b (cm) d (cm) (kg/cm2) S bran.
1 18 70 105 2.45 -0.059 4 2 f 12 use min
###
2 15 25 65 9.23 0.028 2 3 f 8 use min
###
3 15 25 65 9.23 0.028 2 3 f 8 use min
###
4 16 25 65 9.85 0.032 2 3 f 8 use min
###
5 15 25 65 9.23 0.028 2 3 f 8 use min
###
6 15 25 65 9.23 0.028 2 3 f 8 use min
###
7 15 25 65 9.23 0.028 2 3 f 8 use min
###
8 15 25 65 9.23 0.028 2 3 f 8 use min
###
9 15 25 65 9.23 0.028 2 3 f 8 use min
###
10 15 25 65 9.23 0.028 2 3 f 8 use min
###
11 15 25 65 9.23 0.028 2 3 f 8 use min
###
12 15 25 65 9.23 0.028 2 3 f 8 use min
###
13 15 25 65 9.23 0.028 2 3 f 8 use min
###
14 15 25 65 9.23 0.028 2 3 f 8 use min
###
15 15 25 65 9.23 0.028 2 3 f 8 use min
###
16 15 25 65 9.23 0.028 2 3 f 8 use min
###
17 15 25 65 9.23 0.028 2 3 f 8 use min
###
18 15 25 65 9.23 0.028 2 3 f 8 use min
###
19 15 25 65 9.23 0.028 2 3 f 8 use min
###
20 15 25 65 9.23 0.028 2 3 f 8 use min
###
21 15 25 65 9.23 0.028 2 3 f 8 use min
###
22 15 25 65 9.23 0.028 2 3 f 8 use min
###
23 15 25 65 9.23 0.028 2 3 f 8 use min
###
24 15 25 65 9.23 0.028 2 3 f 8 use min
###
25 15 25 65 9.23 0.028 2 3 f 8 use min
###
26 15 25 65 9.23 0.028 2 3 f 8 use min
###
27 15 25 65 9.23 0.028 2 3 f 8 use min
###
28 15 25 65 9.23 0.028 2 3 f 8 use min
###
29 15 25 65 9.23 0.028 2 3 f 8 use min
###
30 15 25 65 9.23 0.028 2 3 f 8 use min
###
31 15 25 65 9.23 0.028 2 3 f 8 use min
###

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Check shear in beams

* Project :

Concrete Fcu = 300 kg/cm2


Concrete qall = 10.73 kg/cm2
Stirrups Fy = 4000 kg/cm2

Ult. Shear Breadth Depth qu As no. of


Sec. Stirrups Notes
Qu (ton) b (cm) d (cm) (kg/cm2) S bran.
32 15 25 65 9.23 0.028 2 3 f 8 use min
###
33 15 25 65 9.23 0.028 2 3 f 8 use min
###

By: Eng. Mahmoud El-Kateb


Concrete Design using the ultimate limit design method

* Design for Torsion

* Project :

Concrete Fcu = 300 kg/cm2

Stirrups Fy = 2400 kg/cm2

Horizontal bars Fy = 3600 kg/cm2

Ult. torsional moment Sec. dim. Ult. shear force


Sec. Mu (m.t) b (cm) t (cm) Qu (ton)
1 4.6 53 57 8

Due to shear qsu Notes


2.90 kg/cm2 use min

Due to torsion qtu Notes


10.22 kg/cm 2
need rft.

Calculation of Rft.

Stirrups due to shear no. f


-6.2 8 /m inner

Stirrups due to torsion no. f


10.3 8 /m outer

or use total stirrups no. f


9 8 /m as min

Horizontal Rft. no. f


6 16

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Rectangular Columns

* Project :

Concrete Fcu = 250 kg/cm2


Steel Fy = 3600 kg/cm2

Ult. Load desired dim of column As Clear


Col. Reinforcement (K) l critical Notes m %
Nu (ton) m% b (cm) t (cm) (cm )
2 Height (m) min

1 25 60 15.00 8 f 16 19.2 Safe 1.25


1 150 1.3 25 55 17.88 9 f 16 4.00 1.20 19.2 Safe 1.25
1.6 25 55 22.00 9 f 18 19.2 Safe 1.25
1 25 80 20.00 10 f 16 19.2 Safe 1.25
2 200 1.3 25 75 24.38 13 f 16 4.00 1.20 19.2 Safe 1.25
1.6 25 70 28.00 12 f 18 19.2 Safe 1.25
1 25 50 12.50 7 f 16 19.2 Safe 1.25
3 120 1.3 25 45 14.63 8 f 16 4.00 1.20 19.2 Safe 1.25
1.6 25 45 18.00 8 f 18 19.2 Safe 1.25
1 25 60 15.00 8 f 16 19.2 Safe 1.25
4 150 1.3 25 55 17.88 9 f 16 4.00 1.20 19.2 Safe 1.25
1.6 25 55 22.00 9 f 18 19.2 Safe 1.25
1 30 60 18.00 9 f 16 16.0 Safe 1.08
5 180 1.3 30 55 21.45 11 f 16 4.00 1.20 16.0 Safe 1.08
1.6 30 55 26.40 11 f 18 16.0 Safe 1.08
1 30 70 21.00 11 f 16 16.0 Safe 1.08
4.00 1.20

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Rectangular Columns

* Project :

Concrete Fcu = 250 kg/cm2


Steel Fy = 3600 kg/cm2

Ult. Load desired dim of column As Clear


Col. Reinforcement (K) l critical Notes m %
Nu (ton) m% b (cm) t (cm) (cm )
2 Height (m) min

6 210 1.3 30 65 25.35 13 f 16 4.00 1.20 16.0 Safe 1.08


1.6 30 60 28.80 12 f 18 16.0 Safe 1.08
1 30 80 24.00 12 f 16 16.0 Safe 1.08
7 240 1.3 30 75 29.25 15 f 16 4.00 1.20 16.0 Safe 1.08
1.6 30 70 33.60 14 f 18 16.0 Safe 1.08
1 30 90 27.00 14 f 16 16.0 Safe 1.08
8 270 1.3 30 85 33.15 17 f 16 4.00 1.20 16.0 Safe 1.08
1.6 30 80 38.40 16 f 18 16.0 Safe 1.08
1 30 100 30.00 15 f 16 16.0 Safe 1.08
9 300 1.3 30 95 37.05 19 f 16 4.00 1.20 16.0 Safe 1.08
1.6 30 90 43.20 17 f 18 16.0 Safe 1.08
1 30 110 33.00 17 f 16 16.0 Safe 1.08
10 330 1.3 30 105 40.95 21 f 16 4.00 1.20 16.0 Safe 1.08
1.6 30 95 45.60 18 f 18 16.0 Safe 1.08
1 30 120 36.00 18 f 16 16.0 Safe 1.08
11 360 1.3 30 110 42.90 22 f 16 4.00 1.20 16.0 Safe 1.08

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Rectangular Columns

* Project :

Concrete Fcu = 250 kg/cm2


Steel Fy = 3600 kg/cm2

Ult. Load desired dim of column As Clear


Col. Reinforcement (K) l critical Notes m %
Nu (ton) m% b (cm) t (cm) (cm )
2 Height
4.00(m) 1.20
min

1.6 30 105 50.40 20 f 18 16.0 Safe 1.08

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Circular Columns

* Project :

Concrete Fcu = 250 kg/cm2


Steel Fy = 3600 kg/cm2

Ult. Load desired Diamter As Clear


Col. Reinforcement (K) l critical Notes m %
Nu (ton) m% D (cm) (cm2) Height (m) min

1 35 9.62 5 f 16 13.7 Safe 0.96


1 100 1.3 35 12.50 7 f 16 4.00 1.20 13.7 Safe 0.96
1.6 35 15.39 7 f 18 13.7 Safe 0.96
1 40 12.56 7 f 16 12.0 Safe 0.87
2 120 1.3 40 16.33 9 f 16 4.00 1.20 12.0 Safe 0.87
1.6 40 20.10 8 f 18 12.0 Safe 0.87
1 45 15.90 8 f 16 10.7 Safe 0.80
3 150 1.3 45 20.67 11 f 16 4.00 1.20 10.7 Safe 0.80
1.6 40 20.10 8 f 18 12.0 Safe 0.87
1 50 19.63 10 f 16 9.6 Safe 0.75
4 180 1.3 45 20.67 11 f 16 4.00 1.20 10.7 Safe 0.80
1.6 45 25.43 11 f 18 10.7 Safe 0.80
1 55 23.75 12 f 16 8.7 Safe 0.70
5 210 1.3 50 25.51 13 f 16 4.00 1.20 9.6 Safe 0.75
1.6 50 31.40 13 f 18 9.6 Safe 0.75
1 55 23.75 12 f 16 8.7 Safe 0.70
4.00 1.20

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Circular Columns

* Project :

Concrete Fcu = 250 kg/cm2


Steel Fy = 3600 kg/cm2

Ult. Load desired Diamter As Clear


Col. Reinforcement (K) l critical Notes m %
Nu (ton) m% D (cm) (cm2) Height (m) min

6 240 1.3 55 30.87 16 f 16 4.00 1.20 8.7 Safe 0.70


1.6 55 37.99 15 f 18 8.7 Safe 0.70
1 60 28.26 15 f 16 8.0 Safe 0.67
7 270 1.3 60 36.74 19 f 16 4.00 1.20 8.0 Safe 0.67
1.6 55 37.99 15 f 18 8.7 Safe 0.70
1 65 33.17 17 f 16 7.4 Safe 0.63
8 300 1.3 60 36.74 19 f 16 4.00 1.20 8.0 Safe 0.67
1.6 60 45.22 18 f 18 8.0 Safe 0.67
1 65 33.17 17 f 16 7.4 Safe 0.63
9 330 1.3 65 43.12 22 f 16 4.00 1.20 7.4 Safe 0.63
1.6 60 45.22 18 f 18 8.0 Safe 0.67
1 70 38.47 20 f 16 6.9 Safe 0.61
10 360 1.3 65 43.12 22 f 16 4.00 1.20 7.4 Safe 0.63
1.6 65 53.07 21 f 18 7.4 Safe 0.63
1 70 38.47 20 f 16 6.9 Safe 0.61
11 390 1.3 70 50.00 25 f 16 4.00 1.20 6.9 Safe 0.61

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Circular Columns

* Project :

Concrete Fcu = 250 kg/cm2


Steel Fy = 3600 kg/cm2

Ult. Load desired Diamter As Clear


Col. Reinforcement (K) l critical Notes m %
Nu (ton) m% D (cm) (cm2) Height
4.00(m) 1.20
min

1.6 65 53.07 21 f 18 7.4 Safe 0.63

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Isolated footings

* Project : ELSADAT FOOTINGS

Concrete Fcu = 300 kg/cm2

Steel Fy = 4000 kg/cm2

Bearing capacity qall = 1.60 kg/cm2

Column working load column dim. extension


foot Nw (ton) b (cm) t (cm) of P.C (cm)
F7 75 30 40 30

Dims. of P.C : B (cm) L (cm) t (cm)


220 230 30 ###
###
Dims. of R.C : B (cm) L (cm) t (cm)
160 170 50

Actual soil stress (kg/cm2) Notes Stress above P.C (kg/cm2)


1.51 safe 2.88 ###

Shear stress (kg/cm2) Notes


3.91 safe ###
###
Punching stress (kg/cm2) Notes
5.98 safe ###

###
Calculation of Rft. : Asmin ###
6.75 cm2 ###
###
Long Rft. : As /m no. f total no.
6.01 4 16 /m 7 ###

Short Rft. : As /m no. f total no.


6.01 4 16 /m 7 ###

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Isolated footings under moment

* Project :

Concrete Fcu = 250 kg/cm2

Steel Fy = 3600 kg/cm2

Bearing capacity qall = 1.50 kg/cm2

Column working load Moment column dim. extension


foot Nw (ton) Mw (m.t) b (cm) t (cm) of P.C (cm)
F1 1000 20 25 50 30
###

Dims. of P.C : B (cm) L (cm) Lmin (cm)


805 830 12
Choose dim of P.C 225 250 ###
###
Dims. of R.C : B (cm) L (cm) t (cm)
165 190 60

Max. Stree (kg/cm2) = 18.67 Unsafe case (2) ###


Min. Stress (kg/cm ) = 2
16.96 No tension ###
Max. Stree (kg/cm ) = 2
18.67 Unsafe case (2)
After Redistribution
Min. Stress (kg/cm2) = 16.96

Shear stress (kg/cm2) Notes


39.682 unsafe ###
###
Punching stress (kg/cm2) Notes ###
54.454 unsafe ###

###
Calculation of Rft. : As /m Asmin ###
96.09 8.25 cm2 ###
###
Long Rft. : no. f total no.
48 16 /m 80 ###

Short Rft. : no. f total no.


46 16 /m 88 ###

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Combined footings

* Project : 55

Concrete Fcu = 250 kg/cm2

Steel Fy = 3600 kg/cm2

Bearing capacity qall = 1.75 kg/cm2

Column working load column dim. (cm) extension


Col Nw (ton) trans. long. of P.C (cm)
exter. 67 40 30 30
inter. 67 30 40 30

Distance from c.g to c.g: 3.83 m ###


###
Resultant of 2 loads is at: 1.92 m from external column
###

Dims. of P.C : B (cm) L (cm) Soil stress (kg/cm2)


minimum 170 475
chosen 300 300 1.65 safe

Dims. of R.C : B (cm) L (cm) t (cm) ###


240 240 60 ###
###
###
###
###
Longitudinal direction: unsafe shear ###
###
Top Rft. : no. f total no. ###
32 12 /m 78 ###

Bottom Rft. : no. f total no. ###


5 16 /m 14 ###
###
Transverse direction: ### unsafe shear ###
###
Top Rft. : no. f total no. ###
5 12 /m 14 ###
###
Bottom Rft. : no. f total no. ###
### 16 /m #VALUE! ###
###
###

Page 26 369352054.xlsx
Concrete design using the ultimate limit design method

* Design of Strap footings

* Project :

Concrete Fcu = 250 kg/cm2

Steel Fy = 3600 kg/cm2

Stirrups Fy = 2400 kg/cm2

Bearing capacity qall = 1.75 kg/cm2

Column working load column dim. (cm) extension


Col Nw (ton) trans. long. of P.C (cm)
exter. 113.5 40 30 0
inter. 67 30 40 0

Distance from c.g to c.g: 3.83 m

Take eccentricity = 0.6 m

Dims. of P.C : B (cm) L (cm)


external footing 515 150
internal footing 515 55

Dims. of R.C : B (cm) L (cm) t (cm)


external footing 515 150 60
internal footing 515 55 60

Longitudinal direction: unsafe bending

Dim. Of strap beam : b (cm) t (cm)


40 70

Rft. Of strap beam : no. f


Top Rft. 25 18
Bottom Rft. 2 16

Stirrups : no. f
5 10 4 branches

Transverse direction:

Bottom Rft. : no. f total no.


external footing 25 16 /m 39 unsafe shear

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

internal footing 23 16 /m 14 unsafe shear

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Pile Caps

* Project :

Concrete Fcu = 250 kg/cm2


Steel Fy = 3600 kg/cm2

Pile Diameter = 0.45 m

Pile Capacity = 100 ton

Cap: PC1

Column Load = 400 ton

Estimated No. of piles = 5 piles

Choose pile spacing from 1.35 to 2.7 m = 1.35 m in long direction

Choose pile spacing from 1.35 to 2.7 m = 1.35 m in short direction

Choose arrangement of piles = 3 x 2 Piles used = 6

Dim of R.C Cap = 4.05 x 2.7 x 0.9 m

Dim of P.C Cap = 4.25 x 2.9 x 0.1 m

Actual Pile Load = 71.2 ton Ok

Moment on Short direction = 150 mt C1 = 5.5007 J= 0.826


As (min) = 33.21 cm2
As (used) = 61.52 cm2 17 f 22

Moment on Long direction = 250 mt C1 = 5.2184 J= 0.826


As (min) = 49.82 cm2
As (used) = 102.53 cm2 27 f 22

By: Eng. Mahmoud El-Kateb


Concrete design using the ultimate limit design method

* Design of Retaining Walls

* Project :

Concrete Fcu = 250 kg/cm2

Steel Fy = 3600 kg/cm2

Bearing capacity qall = 1.50 kg/cm2 0.25 ###

Soil density g = 1.80 ton/m3 0.2 t/m' force

Cohesion of soil C = 0.00 kg/cm2 ###

Angle of friction d = 22 degree ###

3.00

3.00
Coeff. of earth pressure Ka = 0.3 ###

###
0.40

0.85 0.70 ###

###
R.C
0.60 ###
P.C
0.30 ###
1.80 ###
2.00 ###
###
###
Factor of safety against sliding = 1.61

Factor of safety against overturning = 2.05

Max. stress on soil = 1.06 kg/cm2 Safe stress ###


Min. stress on soil = 0.06 kg/cm 2
No tension on soil ###
Max. stress on soil = 1.06 kg/cm2 Safe stress
After Redistribution
Min. stress on soil = 0.06 kg/cm 2

Calculation of Rft. :
###
Mu (m.t) C1 J As (cm ) 2 As min ###
For wall 4.05 5.47 0.826 6.19 3.30 6 f 12
For Base 4.97 12.33 0.826 3.04 8.25 5 f 16

###

By: Eng. Mahmoud El-Kateb


Concrete design according to ECP 203-2007

* Deflection of Cantilevers

* Project :

Concrete Fcu = 250 kg/cm2

Steel Fy = 3600 kg/cm2

PDL+ PLL
WDL+ WLL

Span

Breadth Depth Thickness Span


Sec. Properties of sec: b (cm) d (cm) t (cm) L (m)
1 25 65 70 2.4

Top Rft.: no. f area


5 18 12.72 cm2

Bottom Rft.: no. f area


5 18 12.72 cm2

Working loads: PDL (t) PLL (t) WDL (t/m) WLL (t/m)
2.50 1.50

Initial deflection: 0.14 cm

After long term: 0.21 cm

Allowable value: 0.53 cm

Notes: Safe

By: Eng. Mahmoud El-Kateb


Concrete design according to ECP 203-2007

* Deflection of Simple R-sections

* Project :

Concrete Fcu = 300 kg/cm2

Steel Fy = 3600 kg/cm2

PDL+ PLL
WDL+ WLL

Span/2 Span/2

Breadth Depth Thickness Span


Sec. Properties of sec: b (cm) d (cm) t (cm) L (m)
1 30 75 80 8

Top Rft.: no. f area


4 16 8.04 cm2

Bottom Rft.: no. f area


10 22 37.99 cm2

Working loads: PDL (t) PLL (t) WDL (t/m) WLL (t/m)
10.00 5.00 2.00 1.00

Initial deflection: 0.92 cm

After long term: 1.98 cm

Allowable value: 3.20 cm

Notes: Safe

By: Eng. Mahmoud El-Kateb


Concrete design according to ECP 203-2007

* Deflection of Simple T-sections

* Project :

Concrete Fcu = 250 kg/cm2 B

Steel Fy = 3600 kg/cm2 C As top ts

PDL+ PLL
WDL+ WLL b
h

Span/2 Span/2
C As bottom

Breadth Depth Thickness Span


Sec. Properties of sec: B (cm) b (cm) ts (cm) h (cm) t (cm) L (m)
1 52 12 7 25 32 6

Top Rft.: C (cm) no. f area


3 0 12 0.00 cm2

Bottom Rft.: C (cm) no. f area


3 2 16 4.02 cm2

Working loads: PDL (t) PLL (t) WDL (t/m) WLL (t/m)
0.00 0.00 0.30 0.10

Initial deflection: 0.82 cm

After long term: 2.04 cm

Allowable value: 2.40 cm

Notes: Safe

By: Eng. Mahmoud El-Kateb


Concrete design according to ECP 203-2007

* Design of Water section

* Project :

Concrete Fcu = 300 kg/cm2


Concrete Fctr = 32.9 kg/cm2
Steel Fy = 3600 kg/cm2

Working Moment Normal Force


Sec. Mw (m.t) Nw (t)
1 4.8 5.5 (-ve) for compression

Dims of sec: b (cm) t (cm) fct (kg/cm2)


100 40 19.4

Properties of sec: tv (cm) fct all (kg/cm2)


43.1 19.5 Safe

Design of sec: d (cm) C1 J As calc As min As (cm2)


37 8.42 0.826 7.90 10.28 10.54

use: 6 f 16 bcr = 0.75

By: Eng. Mahmoud El-Kateb

You might also like