You are on page 1of 4

Alcatel-Lucent 1850 TSS-160

T ra n s p o rt S e r v i c e S w i tc h | R e l e as e 3

The Alcatel-Lucent 1850 TSS-160 is a compact version of the Alcatel-Lucent TSS-320. The two models share
the universal switch matrix architecture, operate on a common software release and use common circuit
packs. The Alcatel-Lucent 1850 TSS-160 is a next-generation, Packet-Optical Transport platform that supports
any mix of traffic, from all-circuit to all-packet. With the Alcatel-Lucent 1850 TSS-160, businesses can begin
with circuit-based transport and gradually ramp up packet transport by simply changing line cards. The Alcatel-
Lucent 1850 TSS-160 supports current traffic requirements while eliminating the scalability issues encountered
when traditional multiservice provisioning platforms (MSPPs) are confronted with the high growth of packet-
based traffic.

The Alcatel-Lucent 1850 TSS-160 offers Fully integrates photonic, optical


the flexibility to split increasing traffic and data layers
demands among any combination of Any transport-technology mix
Carrier Ethernet, Transport Multi- Carrier Ethernet service through
Protocol Label Switching (T-MPLS), T-MPLS for standards-based con-
wavelength division multiplexing nection-oriented packet transport
(WDM), optical data unit (ODU) and
SONET/SDH Optical Transport
SDH/SONET transport technologies. It
Hierarchy (OTH) switching, includ-
offers powerful cross-layer network
ing higher-order and lower-order
management and a unied control
(HO/LO) synchronous transport
plane, simplifying operations and
signal (STS) and VC-switching
reducing the total cost of ownership.
Very long haul (VLH)/ultra long
haul (ULH) support
Features
ATM pseudo-wire transport and
Common software and circuit packs gateway functions
with Alcatel-Lucent 1850 TSS-320 Dense WDM (DWDM)
Unique, universal switch architecture Transport-oriented OAM and
Switches packets or circuits in their G-MPLS
native format
Accommodates any traffic mix,
from all-circuit to all-packet
Offers TDM and packet line cards
for technology-specic processing
Delivers multidegree reconfigu- Technical specifications Service level agreement (SLA)
rable optical add/drop multiplexer management
Alcatel-Lucent 1850 TSS-160 Traffic profiles
(ROADM) functionality system
Bandwidth guaranteed
Reconfigurable 44 x 10 G channel Alcatel-Lucent 1850 TSS-160
Regulated: minimum band-
DWDM subrack
width guaranteed plus burst
Wavelength selective switch (WSS) 8 slots, 20 Gb/s per slot: 16 half
slots, 10 Gb/s per half slot Best effort
1 x 9 ports Hitless traffic-profile modification
Two 160 Gb/s protected switching
Mesh capable ROADM up to fabrics Metering
8 degrees Two protected controllers Single Rate Token Bucket:
Protected power supply RFC2697
Up to three subracks in a standard Dual Rate Token Bucket:
Benefits RFC2698
ETSI or ANSI rack
IETF and Metro Ethernet Forum
Switches any combination of packets (MEF) Metering, Policing and
Interfaces
and circuits in their native formats Marking
Data cards
using a single platform Color-blind and color-aware,
10 x Gigabit Ethernet (GE) based on Ethernet priority bits
Fully scales packet transport, smoothly packet module, Small Form-
progressing from all-circuit to all- Factor Pluggable (SFP)
Ethernet functionality
packet, allowing service providers 10 GE packet module, 10 Gb/s
Form-Factor Pluggable (XFP) Ethernet protocol: 802.3
to transform networks to packet Ethernet Media Access Control
Multiservice packet over
transport SONET/SDH (PoS) packet (MAC) autolearning and aging
Efficiently aggregates and grooms module, portless Ethernet-MAC static configuration
metro and long-haul transport ATM gateway packet module, Access Control List (ACL)
portless Virtual LAN (VLAN) push, pop,
Simplifies network planning using swap: service delimiting
SONET/SDH cards
ROADM and WDM Ethernet virtual bridging: 802.1Q
1 x OC-192/ STM-64: XFP
Reduces total cost of ownership and 4 x OC-48/STM-16: SFP Ethernet provider bridging: 802.1ad
simplifies operations through cross- 8 x OC-3-12/STM-1-4: SFP Q in Q
layer network management and 10 x any port card: a data/TDM Rapid Spanning Tree Protocol
unified control plane concentrator: SFP (RSTP) and Multiple Spanning
1 x optical transport unit Tree Protocol (MSTP)
Supports a broad range of applica-
(OTU)-2: 10 Gb/s bidirectional Link aggregation
tions, such as triple play services, transponder, tunable optics Jumbo-frame management
business Ethernet and mobility VLH/ULH cards Y.1731/802.1ag OAM: continuity
backhaul 10 Gb/s booster +10 dBm check (CC), link trace (LT),
10 Gb/s pre-amp +10 dBm loopback (LB)
Fixed OADM (FOADM) DWDM 802.3ah OAM: Ethernet in the
cards (packs) first mile (EFM)
8 channels MUX/DEMUX, Eight Quality of Service (QoS)
L1band classes
8 channels MUX/DEMUX, Two levels QoS: per class, per
L2band transport service
Optical amplifier 22/9 17 dB Ethernet flow, RGY counters
10 G transponder, client and L2 control protocol filtering/
line pluggable: XFP tunneling
ROADM DWDM cards (packs) Metro Ethernet Forum (MEF) 9
and MEF 14 certified: EPL, EVPL
Optical protection switch and E-LAN
DWDM ROADM wavelength Ethernet traffic classification
router
Port
DWDM transponder: tunable
line optics, XFP client Ethernet VLAN
DWDM MUX/DEMUX Ethernet priority bits
DWDM amplifier IP v4 differentiated services
code points (DSCP)
EtherType
MPLS Exp bits

2 Alcatel-Lucent 1850 TSS-160 | Release 3 | Data Sheet


Ethernet forwarding criteria Protection Environment

Port Ethernet network protection Operating temperature:


Port plus MAC -5C to +45C (23F to 113F)
RSTP: 802.1w
Port plus VLAN Relative humidity: 0% to 90%,
MSTP: 802.1s
non-condensed
Port plus MAC plus VLAN Link aggregation
Port plus MAC plus VLAN plus T-MPLS network protection Regulatory compliance
Prio bits
Tunnel Lin Protection 1:1 CE and UL certification
Unicast traffic
SONET/SDH network protection NEBS level 3
Multicast traffic
Single- and dual-ended APS 1 + 1 FCC part 15 class A
Broadcast traffic
Subnetwork Connection ETSI
Protocol (SNCP), unidirectional
Dimensions: Alcatel-Lucent 1850
IGMP functionality path-switched ring (UPSR)
TSS-160 subrack
Internet Group Management Multiplex Section-Protection
Protocol (IGMP) snooping Subrack dimensions
Ring (MSPRING) 2F bidirectional
IGMP proxy line switching ring (BLSR) Height: 304 mm (12.0 in.)
IGMP fast leave Equipment protection Width:498 mm (19.6 in.)
Power protection Depth: 290 mm (11.4 in.)
ATM functionality Controller protection Designed to be installed in a
Pseudo-wire emulation edge to standard ETSI rack
Universal switch protection
edge (PWE3): ATM-PWE3 gateway Height: 2.20 m (7.2 ft.)
OC-3/STM-1 ATM unchannalized G-MPLS control plane Width: 600 mm (23.6 in.)
ATM virtual path identifier/virtual T-MPLS tunnel setup Depth: 300 mm (11.8 in.)
channel identifier (VPI/VCI) Power and cooling
TDM HO path setup
N:1 mapping with PWE3 static
configuration Power supply: DC feed (-48-V DC
Management nominal)
ATM QoS, OAM F4, F5: PWE OAM
Alcatel-Lucent 1350 Optical Power supply: -65-V
Management System (OMS) Power consumption: up to 2000 W
T-MPLS functionality
TL1 Cooling: forced air
Data plane: T-MPLS, MPLS
Zero-installation craft (ZIC) terminal Environment
T-MPLS OAM: CV, automatic pro-
tection switching (APS), forward Command line interface (CLI) Operating temperature:
defect indication (FDI) Simple Network Management -5C to +45C (23F to 113F)
Tunnel Lin Protection 1:1 Protocol (SNMP) Relative humidity: 0% to 90%,
Ethernet line (E-line), E-LAN Secure Shell (SSH) v2/Secure non-condensed
and E-Tree Sockets Layer (SSL) for secure
connection Regulatory compliance
SONET/SDH functionality CE certification
Physical specifications Operating conditions:
Cross-connection
ANSI ETS 300 019, Class 3.2
Termination
Ethernet mapping over SONET/SDH
Dimensions: Alcatel-Lucent 1850 Storage conditions:
TSS-160 subrack ETS 300 019, Class 1.2
Generic framing procedure:
Subrack dimensions Transportation conditions:
GFP, G.7041
Height: 304 mm (12.0 in.) ETS 300 019, Class 2.2
Virtual concatenation (VCAT)
Width: 498 mm (19.6 in.) Electrostatic discharge (ESD)/elec-
Link capacity adjustment scheme tromagnetic compatibility (EMC):
(LCAS) Depth: 305 mm (12.0 in.)
ETS 300 386 Telecommunications
or 356 mm (14.0 in.)
Performance monitoring Center
Designed to be installed in a
HO and LO capabilities
standard ANSI rack
Height: 2.13 m (7.0 ft.)
DWDM functionality
Width: 660 mm (26.0 in.)
Node configurations
Depth: 305 mm (12.0 in.)
Terminal
or 356 mm (14.0 in.)
In-line amplifier (ILA)
Power and cooling
Network configurations
Power supply: DC feed (-48-V DC
Point-to-point nominal)
Linear Power supply: -58-V
Ring Power consumption: up to 2000 W
Mesh Cooling: forced air

Alcatel-Lucent 1850 TSS-160 | Release 3 | Data Sheet 3


www.alcatel-lucent.com Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo
are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility
for inaccuracies contained herein. Copyright 2008 Alcatel-Lucent. All rights reserved.
CAR4688080916 (09)

You might also like