You are on page 1of 1

SAIPEM UK HSE Main C10 Sub IMC 91146

Material/Process ELECTROCLEAN E Keyword Cleaner (Solvent) MEDIUM HAZARD Hazards


Supplier NALFLEET MARINE CHEMICALS Date 27/11/2007
Contents LIQUID
Address C11-C15 Iso alkanes 80-100%, Methoxy Exp Limit
Winnington Avenue propoxy propanol 1-20%, Methoxy propoxy propanol
PO Box 11 308mg/m3 8hTWA WEL,
Northwich Cheshire
CW8 4DX
01606 74488

Health Risks Risk Assessment 2


HARMFUL: MAY CAUSE LUNG DAMAGE IF SWALLOWED Activity Comments
Method: Hand applying
MAY CAUSE EYE IRRITATION
Area: Any area (not confined)
SKIN - IRRITATION AND DERMATITIS MAY RESULT FROM PROLONGED CONTACT
Exposure Time: 1/2 to 2 hours daily
Do not breathe in vapour
When using do not eat, drink or smoke Control Measures
Avoid contact with skin and eyes

Spillage
VENTILATE AREA
DO NOT ALLOW UNCONTROLLED SPILLAGES TO ENTER MAINS DRAIN/SEWERS/WATER
COURSES
WEAR NITRILE GLOVES KEEP SKIN NITRILE IF SPLASH OR OR
WEAR EYE PROTECTION (GRADE 3) IF SPLASH LIKELY COVERED LIKELY
WEAR PROTECTIVE OVERALLS & CHEMICAL PROOF FOOTWEAR
ABSORB IN SAND OR INERT ABSORBENT MATERIAL
COLLECT INTO A CONTAINER, CLOSE LID
DISPOSE OF USING SUITABLE PROCEDURE OR SEEK L.A. GUIDANCE

First Aid
ISOLATED SMALL SCALE FIRE:
AFTER A SIGNIFICANT EXPOSURE CALL FOR MEDICAL ASSISTANCE IMMEDIATELY
INGESTION - DO NOT INDUCE VOMITING
INGESTION - GIVE PLENTY OF WATER IN SIPS EATING OR WASH AFTER IF HEAVILY AFTER USE
INGESTION - GET IMMEDIATE MEDICAL ATTENTION DRINKING CONTACT SOILED
EYE - IRRIGATE WITH WATER FOR AT LEAST 15 MINUTES
SKIN - WASH WITH SOAP/CLEANSER AND RINSE WITH WATER
IF IRRITATION PERSISTS THEN CONSULT A DOCTOR Considerations Details
If using engineering
controls/non disposable PPE
Fire ensure maintenance (reg 9)
ISOLATED SMALL SCALE FIRE:
WATER FOG - CARBON DIOXIDE - POWDER - FOAM
DO NOT USE WATER JET
LARGE FIRE: EVACUATE AREA, CALL FIRE BRIGADE OR FOLLOW SITE PROCEDURE
WEAR SELF-CONTAINED BREATHING APPARATUS AND PROTECTIVE CLOTHING
TOXIC FUMES ARE PRODUCED WHEN SUBSTANCE IS INVOLVED IN A FIRE
Safety Data Sheet Reference
CHIP SDS 24/1/97

This assessment was compiled by Sypol Limited from supplier's safety data
sheets. Safety in the use of assessments is the responsibility of the Printed 15/03/2010
subscriber.