You are on page 1of 1

A D

B
H
127
63 69 80 87 126 A
75 98
64 70 81 88
65 76 125
71 82 89 123
RESTRICTED ACCESS
BEARING PILES 66 77 83 124
72 90 95
67 73 78 84 99 121 D
91 122
E 74
79 119
85 92 96
68 100 120
23 86 93 97 RETAINING WALLS - MALE PILES ONLY
31 101 118 RESTRICTED ACCESS PILING: SECANT PILES, 450mm DIA.

1 128 39a 54 8.0m LONG, at 575mm c/c, REINF: 7H40 +10mm HELICAL AT
150, PLAN LENGTH 33.2m
45 117
24 C RESTRICTED ACCESS PILING: SECANT PILES, 450mm DIA.
7.0m LONG, at 675mm c/c, WATER CUT-OFF WALL
(SOFT-SOFT PILES) PLAN LENGTH 17m

10 32 39 55 116 RESTRICTED ACCESS PILING: CONTIGUOUS PILES, 450mm


DIA. 21.0m LONG, at 675mm c/c, REINF: 7H40 +10mm
102 HELICAL AT 150, PLAN LENGTH 19.5m, PPL:-5.50

2 17 RESTRICTED ACCESS PILING: SECANT PILES, 600mm DIA.

25 46 56 25.0m LONG, at 750mm c/c, REINF: 13H40 +16mm HOOPS AT


115 100, PLAN LENGTH 80.5m

33 40 RESTRICTED ACCESS PILING: SECANT PILES, 600mm DIA.

18 57 103 114 27.5m LONG, at 750mm c/c, REINF: 13H40 +16mm HOOPS AT
47 100, CAGE LENGTH 25.0m, PLAN LENGTH 8.5m

3 11 26
34 50 52
D RESTRICTED ACCESS PILING: SECANT PILES, 600mm DIA.
30.0m LONG, at 750mm c/c, REINF: 13H40 +16mm HOOPS AT
100, CAGE LENGTH 25.0m, PLAN LENGTH 11.0m

141 142 8 12 41
19 104 113 RESTRICTED ACCESS PILING: SECANT PILES, 600mm DIA.
RESTRICTED ACCESS
BEARING PILES G 27 35 42 51 53
10.0m LONG, at 900mm c/c, REINF: 6H16 +10mm HELICAL AT
200, CAGE LENGTH 5.0m, PLAN LENGTH 11.0m

143 144 UNRESTRICTED PILING: SECANT PILES, 900mm DIA. 25.0m


27a 35a 42a 108 112 LONG, at 1350mm c/c, REINF: 15H40 +16mm HOOPS AT 100,
PLAN LENGTH 185m

48 58
105 PILES TO HAVE 1:150 VERTICAL TOLERANCE
20 (APPLIES TO FEMALE PILES AS WELL)

9 28 43 109
13
F 14
36
49 59 61 106
E 4
21 110 C
133 134 29 04 AS CLOUDED
RESTRICTED ACCESS
132 37 44 107 111 BM 19/10/2017

BEARING PILES
60 62 03 BEARING PILES ADDED
DESIGN CASES AND PILE
BM 16/10/2017

136 137
E 135 22
02 LENGTHS AMENDED TO SUIT
AXIAL LOADS
BM 09/10/2017

5 15 01 FIRST ISSUE BM 02/10/2017

30
138 139 140 16 38 PRELIMINARY

C D Toureen Group
25 Cecil Road
Harrow
13500 8300 12150 Middlesex HA3 5QY
E PILES TO HAVE 1:150 VERTICAL TOLERANCE PILES TO HAVE
1:150 VERTICAL
TOLERANCE
PILES TO HAVE 1:150 VERTICAL TOLERANCE Tel: 020 8424 7999
www.toureenmangan.co.uk
AXIAL COMPRESSION
129 131 PILES WILL SUPPORT TEMPORARY
LOADS OF 750kN/m(DL) NOTES: LOADS ON SECANT WALL -
-
130 PPL PILES: -1.60mOD U.N.O.
CONCRETE COVER: 75mm Section of secant -
DL LL -
CONCRETE: C32/40 U.N.O. wall
HEADROOM FOR RESTRICTED PILING: 4.5m
*GENERAL SURCHARGE AT THE BACK OF THE kN/m kN/m -
-
RETAINING WALLS 230kPa DL SLS U.N.O
*ALL LOADS SHOWN ARE SLS A 1250 100 -
-
B 830 150

C 950 100 OLD WAR OFFICE


D 650 45

E 600 160 PILE LAYOUT


F 1300 270

G 730 170 1:150 02/10/2017 BM IF


H 970 90
TCL-663 sk-005 04