fact sheet
fact sheet
LM6000-PF+ package Package Optional equipment/
configuration Auxiliary module
80 dBA average near field design
services
Electro-hydraulic start system for
Gas Turbine 10-minute start SPRINT power enhancement
19 stage axial compressor: ATEX category 3G, gas group IIA, suitable Generator options:
5 stages low pressure and 14 stages high electrical system where required TEWAC, CACA
pressure Turbine/generator control system Voltages from 10.5 kV to 11.5 kV
Horizontal split casing GEs Mark* VIe digital control system with Dual AVR
33:1 compression ratio human machine interface (HMI) Fuel system:
134 kg/s nominal inlet mass flow Lube oil system with duplex shell and Gas
tube coolers
Triple annular combustor: Liquid fuel capability
Turbine factory tested
30 premixer assemblies with 75 gas fuel Control system:
injection cups On-/off-line water wash
Black start for island operation
Two-stage high pressure and five-stage 1-year parts/service warranty and RM&D
Continuous emission monitoring
low pressure power turbine. Package familiarization training
Remote display to control or monitor
Electronically transmitted drawings the unit
Gearbox Startup technical assistance Power and control module
Horizontal parallel offset, double helical Motor control center
High efficiency of 99% Air filtration and Woodward MICRONET+ control system
High service factor 1.2 (API), 2.2 (AGMA) ventilation SIS for ISO 21789 compliancy
Static filtration G4+F8 24 x 14 drawers Battery system with charger
Generator on Gas Turbine air (24 VDC, 125 VDC)
11.5 kV, 0.8P F for 50 Hz segment Static filtation G4 24 x 24 drawers Lube oil system:
on ventilation
13.8 kV, 0.85 PF for 60 Hz segment Oil/water coolers
80 dBA max. at 1 meter (side) off all
2-pole, 3-phase, brushless exciter First fill lubricants
intake and outlet ducts (including
IP54 weather protected transients) Air filtration and ventilation:
Voltage line/neutral side protection CTs Ventilation only with direct-driven fans HEPA (E11) filtration on GT intake
Class F insulation and B temperature rise Cartridge filters with or without pulse
cleaning
Integrated generator protection relay
panel Static filtation G4+F8 24 x 24 drawers
on ventilation
AOC cooling module
Inlet conditioning for enhanced efficiency:
Evaporative cooling
Mechanical chilling/heating/anti-icing
Heating
Others:
Winterization packages down to 39F
Gas vent silencer