You are on page 1of 12

Installation/Workover

Control Systems
Installation/Workover Control Systems (IWOCS)

CAMSERV Cameron Controls provides a compre- Shallow Water Vertical Completions


Aftermarket Services hensive range of IWOCS to meet the IWOCS for shallow water, vertical com-
For the life of your project and your requirements of vertical and horizontal pletions provide DH control of tree func-
equipment CAMSERV Aftermarket completions in all water depths. Systems tions and a failsafe pilot control system
Services offers a one-stop approach to are available for rental and outright pur- for the LMRP. DH control is provided for
any service-related need. chase, as well as re-purchase after initial THRT functions.
large-development demand. Options are available to provide simple
This diverse offering allows Cameron hydraulic interlocking of LMRP and tree
Controls to provide cost-effective solutions functions to ensure correct sequencing of
from single well satellites to large deep- the valves in the vertical flow path and
water, multi-well developments in the prevent inadvertent closure of tree valves
most remote corners of the globe. on coiled tubing or wire line. DH control
High-reliability IWOCS operate of SSTT functions and related control panel
Through 60 worldwide Service Centers,
hydraulic functions during installation, functions are additional options.
linked through Camerons global product
intervention and workover of subsea Major system elements typically include:
search integrated within SAP-R3, CAMSERV
completion equipment and provide HPU and Workover Control Panel
offers a broad range of quality services, as
facilities for monitoring and testing Workover Reel and Umbilical
well as reconditioned products and OEM
various subsea functions. Tubing Hanger Reel and Umbilical
replacement parts to keep projects running
Most developments use one of four field- EDP and LMRP Pilot Valve Modules
smoothly. CAMSERV services include:
proven standard system configurations to and Accumulators
Equipment repair and re-manufacture
minimize the cost and duration of subsea Deepwater Vertical Completions
Reconditioned equipment sales, rental interventions and workovers throughout IWOCS for deepwater, vertical completions
and exchange the whole life of the field. Custom design provide EH control of tree functions, LMRP
Replacement parts solutions are available to meet specific and EDP via a WSCM located on the EDP.
Field services requirements and applications. The system features rapid operation of
Computerized customer asset all workover functions including
management services closure of the LMRP rams and
Consignment programs
valves and operation of the EDP,
critical when operating from a
CAMSERV brings you more ways to
dynamically positioned vessel in
minimize your Total Cost of Ownership.
deepwater. DH control is provided
And only CAMSERV offers the worldwide
for the THRT functions.
resources of Cameron, with the 24/7
Options are available to provide
convenience and personal, responsive
redundancy, operation of tree func-
service of a local supplier anywhere
tions via the production SCM and
you are.
provision of acoustic back-up
systems. DH control of SSTT
functions and related control panel
Whole Life Target Chart
(Showing Relative Time Value Opportunity) functions are additional options.
Cameron SpoolTree Subsea Production System

CONTRACT AWARD

TRAINING PROGRAM PREPARATION C U S T


SYSTEM OPTIMIZ. DESIGN ENGINEERING,
FEED ITT SYSTEM PROPOSAL & ENGINEERING MANUFACTURING & PROCUREMENT

ORGANIZATIONAL LEARNING INPUT; CUSTOMER CARE, AFTERMARKET AND OPERATIONS

C A M S E R V A N D W H O L E L I F E O F D E V E L O P M E N T S U
EH control systems for integrated control workover umbilical at the LMRP/BOP Workover System Terminology
of the THRT and SSTT are also available. interface. Acronym Description
Major system elements typically include: Options are available to operate and BOP Blowout Preventer
HPU and Workover Control Panel monitor tree functions via the TRT during
DH Direct Hydraulic
Workover Reel and Umbilical installation, and test/monitor the DHPT
DHPT Downhole
Tubing Hanger Reel and Umbilical following installation of the tubing hanger. Pressure/Temperature
Workover Control Module and DH control for THRT functions, SSTT func- Transmitter
Accumulators tions and related control panel functions EDP Emergency Disconnect Package
LMRP Pilot Valve Module and are additional options. EH control systems EDU Emergency Disconnect Unit
Accumulators for integrated control of the THRT and
EH Electro-Hydraulic Multiplex
Remote Workover Control SSTT are also available.
ESD Emergency Shutdown System
Unit/Portable Electronic Test Unit Major system elements typically include:
HPU and Workover Control Panel HP High Pressure
Shallow Water Horizontal Completions
Workover Reel and Umbilical HPU Hydraulic Power Unit
IWOCS for shallow water, horizontal com-
Tubing Hanger Reel and Umbilical IWATS Installation Workover
pletions provide DH control of the TRT Autonomous Test System
Emergency Disconnect Unit
and tree functions. An EDU installed on
BOP and TRT Accumulator Units IWOCS Installation Workover Control
the LMRP/BOP enables disconnection of System
ROV Flying Leads from BOP to Tree
the workover umbilical at the LMRP/BOP LMRP Lower Marine Riser Package
Remote Workover Control
interface.
Unit/Portable Electronic Test Unit LP Low Pressure
Options are available to operate and
MDU Mobile Drilling Unit
monitor tree functions via the TRT during
installation, and test/monitor the DHPT MTU Master Telemetry Unit
following installation of the tubing hanger. PETU Portable Electronic Test Unit
DH control for THRT functions, SSTT PLC Programmable Logic Controller
functions and related control panel func- ROV Remotely Operated Vehicle
tions are additional options. Major system RTU Remote Telemetry Unit
elements typically include:
SAM Subsea Accumulator Module
HPU and Workover Control Panel
SCM Subsea Control Module
Workover Reel and Umbilical
Tubing Hanger Reel and Umbilical SimOps Simultaneous Workover and
Production Operation Scenarios
Emergency Disconnect Unit
SSTT Subsea Test Tree
ROV/Diver Flying Lead Jumpers
from BOP to Tree THRT Tubing Hanger Running Tool
TRT Tree Running Tool
Deepwater Horizontal Completions
WHPU Workover Hydraulic Power Unit
IWOCS for deepwater, horizontal com-
pletions provide EH control of tree func- WSCM Workover Subsea Control
Module
tions and DH control of the TRT via the
WOCS Workover Control System
production SCM. An EDU installed on the
LMRP/BOP enables disconnection of the
Cameron Vertical, Dual-Bore Subsea Workover System

FIRST OIL/GAS

T O M E R T R A I N I N G P R O G R A M S

FATs FIT SIT INSTALL COMMIS. PRODUCTION PMIS* PRODUCTION PMIS* PRODUCTION PMIS* PRODUCTION DECOMMISSIONING
SUPPORT

P R O D U C T I N T E G R I T Y & H S E P R O G R A M S

P P O R T
*P M I S (PLANNED MAINTENANCE & INTERVENTION SUPPORT)
3
Installation/Workover Control System Equipment

Workover Hydraulic Power Unit lay during de- terminate the subsea umbilical hydraulic
The WHPU is the primary system com- ployment and hoses, while wet-mateable connectors
ponent of the retrieval. A terminate the electrical cables for DHPT
IWOCS. It failsafe brake monitoring.
provides the prevents
Workover Hydraulic Deck Jumper
hydraulic drum rotation
The workover hydraulic deck jumper con-
power to when the
nects the WHPU and workover reel. The
operate the umbilical is
jumper consists of an unarmored thermo-
various run- suspended Workover/TRT Reel with Umbilical
plastic hydraulic bundle terminated at each
ning tools, and during
end with stab plates.
and subsea tree IWOCS operations. Wet-mateable
Workover Hydraulic
Power Unit valves. WHPUs connectors terminate the subsea umbilical Workover Electrical Deck Jumper Power
typically include: electrical cables when provided for EH The workover electrical deck jumper inter-
Dual redundant LP and HP operations or DHPT monitoring, while a connects an EH WHPU and workover reel,
pump systems multi-way stab plate terminates the subsea providing dual power channels for pro-
Dual reservoirs umbilical hydraulic hoses. duction and workover SCMs. The jumper
Filtration to NAS 1638 Class 6 consists of an armored offshore electrical
THRT Reel and Umbilical
Independent transfer and clean-up cable terminated with multi-pin explosion
The THRT reel and umbilical is a reeled,
pump and filter system proof connectors at each end.
multi-way hydraulic umbilical providing
LP and HP accumulation Workover Electrical Deck Jumper Signal
communication connections to control
Local control panels for HPU The workover electrical deck jumper inter-
THRT functions. A hand-held remote
and workover functions connects an EH WHPU and workover reel,
pendant enables operation from an adjacent
PLC control for EH systems providing dual communications channels
location. An automatic
The integrated local control panel for production and workover SCMs The
spooling device
provides control of tree functions, TRT/ jumper consists of an armored offshore
ensures correct
workover umbilical reel and the THRT electrical cable terminated with multi-
umbilical lay during
umbilical reel. pin explosion proof connectors at
deployment and
Workover/TRT Reel and Umbilical retrieval, while a each end.
The workover/TRT reel and umbilical is a failsafe brake THRT Hydraulic Deck Jumper
reeled, multi-way EH umbilical providing prevents drum The THRT hydraulic deck jumper
power and communication connections to rotation when the interconnects the WHPU and THRT
control TRT and tree functions. A hand- umbilical is reel. The jumper consists of an unarmored
held remote panel enables reel operation suspended and THRT Reel
with Umbilical thermoplastic hydraulic bundle terminated
from an adjacent location. An automatic during opera- with stab plates at each end.
spooling device ensures correct umbilical tions. Individual hydraulic couplers

Complete DH Rental IWOCS System - Subsystems left to right - Test Stand, THRT Reel and Umbilical, ESD Station, WHPU, Deck Jumper, Sheave, Workover Reel and Umbilical
Umbilical Sheaves SCM house- Common Components DH and EH,
The umbilical sheaves assist deployment keeping and Vertical and Horizontal Systems
of the workover/TRT and THRT control diagnostic Workover Hydraulic Power Unit
umbilicals and are sized to ensure that an data that is
Workover/TRT Reel and Umbilical
umbilical cannot be bent beyond not normally
available on Tubing Hanger Running Tool Reel
and Umbilical
the WHPU
Portable Electronic Test Unit
operating Workover Hydraulic Deck Jumper
panels. The PC-based, laptop unit Tubing Hanger Running Tool Hydraulic
incorporates a power supply, communica- Deck Jumper
tions equipment and interconnecting cables Umbilical Sheaves
Jumper Transportation and Storage Basket with Sheave to enable remote location test and operation
Remote Emergency Shutdown Station
recommended minimum bend radius. diagnostics. Data is stored on the internal
Sheave rollers are made from corrosion- CD-RW drive. The standard portable elec- Remote Emergency Shutdown Station
resistant material and provide smooth, tronic test unit is suitable for use in safe Deck Cable/Jumper
abrasive free movement of an umbilical. areas only. Jumper Deployment Basket
Remote ESD Station Jumper Basket Umbilical Clamps (THRT
The remote The offshore/lift certified jumper basket Umbilical-to-Drill Pipe/Riser)
ESD station provides for the transportation and storage Workover Control System Radio Link
consists of deck jumpers and sheaves. Workover Umbilical Test and
of push Flushing Unit
Emergency
buttons and
Disconnect Installation Workover Autonomous
indicators Test System
Unit
suitable
The EDU IWATS Tree-to-BOP Connector
for Zone 1
enables safe Additional Components for EH
hazardous
disconnect of Vertical and Horizontal Systems
Remote ESD Station area opera-
the surface,
tions and can be reconfigured to meet the Workover Electrical Power Deck Jumper
rig-mounted,
rig-specific safety requirements. The unit Workover Electrical Signal Deck Jumper
equipment
functions to initiate a single level shut-
from the Portable Electronic Test Equipment
down of the IWOCS and a remote shut-
fixed subsea
down of the subsea production system. Emergency Disconnect Unit Workover Subsea Control Module
equipment
Protective covers prevent accidental BOP Accumulator Module
during drilling unit drift, drive-off or other
initiation of ESDs.
emergency situations. The unit consists of a Tree Running Tool Accumulator Set
Remote ESD Station Deck Cable/Jumper multi-way remotely operated hydraulic and Additional Components for DH
The remote ESD station deck jumper con- electrical stab plate at the LMRP/BOP stack and EH Horizontal Systems
nects to the remote ESD station, providing interface, allowing the workover functions
Emergency Disconnect Unit
safe remote communications to operate an to be disconnected between the tree and the
ESD. The jumper consists of an armored workover umbilical in the event that the Emergency Disconnect Unit Test
drilling riser is disconnected from the BOP. and Shipping Frame
offshore electrical cable terminated at
each end with multi-pin, explosion proof Umbilical Clamps (Umbilical-to-SCM line)
EDU Test and Shipping Frame
connectors (for deepwater systems) or Tree Running Tool-to-Tree Flying Lead
The EDU test and shipping frame protects
an unarmored thermoplastic pneumatic
the EDU from damage during storage and Tree Flying Lead Parking Plate
hydraulic bundle terminated at each
offshore transportation. The unit enables
end with stab plates (for shallow water BOP-to-Tree Flying Lead
checking, flushing and pressure testing of
systems). Tree to BOP Parking Plate
EDU operations prior to installation on
Portable Electronic Test Unit the BOP.
The PETU is a multi-purpose system
providing operator access to production
Installation/Workover Control System Equipment

deployment of the TRT, or to the choke and hydraulic flying lead allowing operation
kill lines during deployment of the BOP of the production SCM and control of tree
stack. The clamps ensure the umbilical is functions following lockdown of the tree
adequately attached at all times to prevent with the TRT connected. The flying lead
any damage to the umbilical. provides compensation for the SCM
hydraulics from the IWOCS during tree
WOCS Radio Link
installation.
The WOCS radio link system provides a
highly secure, line-of-sight, dual channel Tree Flying Lead Parking Plate
WSCM (cover and HydraQuads ESD communications link between a MDU The tree flying lead parking plate allows
removed for clarity)
and a fixed platform or floating production parking and protection of the tree flying
WSCM
system. The system is intended for use lead when not connected to the tree pro-
The WSCM uses CAMTROL production
under SimOps and provides the ability to duction controls stab plate. A parking plate
control system technology to provide a
initiate a fully automated shutdown of the on the BOP allows flying lead parking
compact, lightweight system for operating
subsea production facility from the MDU when running or retrieving the BOP stack
vertical tree workover functions and light
or other workover/intervention vessel. and drilling riser. A second parking plate
intervention control systems. The WSCM is
Major components of the system include is fitted to the TRT to allow parking of the
easily removable on deck for maintenance
an MTU located on the production facility, tree flying lead following disconnection at
and provides dual redundant electronics.
and a RTU and ESD panels located on the the end of the Tree running sequence prior
Use of a common power and communica-
MDU. Alarms are raised at both ends of to recovery of the TRT.
tions system is possible for workover and
the link in the event of any communication
production SCMs, allowing a truly inte- ROV Hot Stab Blind Receptacle
errors or system failures.
grated control system. The ROV hot stab blind receptacle is
Workover Umbilical Test attached to the BOP stack or TRT for
BOP Accumulator Module
and Flushing Equipment parking the ROV test stab flying lead and
The BOP accumulator module provides
The workover umbilical test and flushing testing the IWOCS pressure test line during
hydraulic power for the production SCM
equipment allows all elements of the the running or retrieving of the BOP stack.
using dedicated accumulators on each
IWOCS to be flushed and tested prior to
supply for systems not configured with BOP-to-Tree Flying Lead
use or during routine offshore maintenance.
subsea accumulators on the tree. The The BOP-to-tree flying lead is a multi-
Typical uses include pressure test and
module is mounted to the BOP stack in a function, ROV fly-to-place electric and
flushing, and continuity and
robust framework that provides protection hydraulic flying lead allowing operation of
insulation tests.
during BOP handling. the production SCM and control of the tree
ROV Test Stab Flying functions during installation and workover
TRT Accumulator Set
Lead operations with the BOP in place. The
The TRT accumulators provide
The ROV/test flying lead connects to the BOP stack-
hydraulic power to the pro-
stab flying lead mounted EDU and accumulator module
duction SCM to enable testing
is a single-line, to the production control system stab
of the tree when initially run.
ROV fly-to- plate on the tree.
Accumulators are provided for
place hydraulic
each hydraulic supply line. IWATS Tree-to-BOP Connector
flying lead
and EDP Functions Flying Lead
Umbilical Clamps THRT allowing testing
The IWATS tree-to-BOP connector and EDP
Umbilical-to-Drill Pipe/Riser of the tree
functions flying lead is a multi-function,
Clamps are provided to clamp the TRT Accumulators connector gasket
ROV fly-to-place electric and hydraulic
THRT umbilical to the drill pipe or and tubing
flying lead. It allows operation and testing
completion riser for tubing hanger hanger/ HP cap seals. One end of the
of the various EPD and BOP connector test
deployment. The clamps ensure the flying lead is permanently attached to the
ports during installation and workover
umbilical is adequately attached to prevent BOP stack EDU, while the second end is
operation with the IWATS. The flying
umbilical damage. fitted with an ROV fly-to-place hydraulic
lead interconnects the tree to the EDP and
hot stab.
Umbilical Clamps associated accumulator module and the
Workover Umbilical-to-SCM Line TRT-to-Tree Flying Lead BOP connector test ports.
Clamps are provided to clamp the work- The TRT-to-tree flying lead is a multi-
over umbilical to the drill pipe used for function, ROV fly-to-place electric and
Rental IWOCS Specifications

Configurable Rental IWOCS Features: Components are suitable for use with the control fluid intended for use. All system filters have been
specified to ensure fluid is clean to NAS 1638 class 6. A pneumatic line for the remote ESD stations is provided. *Hydraulic fluid provided at
two regulated pressure levels, LP at 345 bar (5000 psi) and HP at 690 bar (10,000 psi).

Hydraulic Lines Elect.


Unit Length Width Height Weight Umbilical
Line Qty
Component Number (m/ft) (m/ft) (m/ft) (kg/lb) (m/ft)
Qty Size bar/psi (2.5 mm2)
1 3.80/12.5 2.20 /7.2 2.60/8.5 6000/13,300
2 3.80/12.5 2.20/7.2 2.60/8.5 6000/13,300
3 3.50/11.5 2.20/7.2 2.60/8.5 7600/16,800
HPU*
4 3.60/11.8 2.20/7.2 2.60/8.5 7000/15,500
5 3.50/11.5 2.20/7.2 2.60/8.5 7000/15,500
6 3.10/10.2 2.00/6.6 2.00/6.6 4100/9000
7 1/4 775/11,250
1 3.40/11.2 2.08/6.8 3.15/10.3 9800/21,600 2 300/1000
5 3/8 345/5000
7 1/4 775/11,250
2 3.40/11.2 2.08/6.8 3.30/10.8 9800/21,600 2 290/950
5 3/8 345/5000
7 1/4 860/12,500
THRT Reels 3 3.23/10.6 2.23/7.3 3.00/9.8 6100/13,500 3 300/1000
5 3/8 345/5000
3 1/4 860/12,500
4 3.41/11.2 3.41/11.2 3.41/11.2 16,350/36,100 7 1/4 690/10,000 1060/3500
4 1/4 345/5000
10 1/4 775/11,250
1 3.80/12.5 2.50/8.2 3.60/11.8 10,200/22,500 23 3/8 345/5000 2 300/1000
2 1/2 345/5000
10 1/4 860/12,500
2 3.80/12.5 2.43/8.0 3.35/11.0 8500/18,800 23 3/8 345/5000 2 300/1000
2 1/2 345/5000
10 1/4 775/11,250
3 3.80/12.5 2.43/8.0 3.60/11.8 11,000/24,300 22 3/8 345/5000 2 245/800
Workover 2 1/2 345/5000
Reels 10 1/4 860/12,500
4 3.80/12.5 2.65/8.7 3.55/11.6 9850/21,700 22 3/8 345/5000 2 300/1000
2 1/2 345/5000
10 1/4 860/12,500
5 3.80/12.5 2.65/8.7 3.55/11.6 9300/20,500 22 3/8 345/5000 2 300/984
2 1/2 345/5000
3 1/4 860/12,500
6 3.41/11.2 3.41/11.2 3.41/11.2 16,350/36,100 4 1/4 690/10,000 1060/3500
11 3/8 345/5000
Universal 1 3.23/10.6 2.23/7.3 3.00/9.8 8350/18,400 24 1/4 690/12,500 4 200/650
Reels 3 3/8 690/10,000
2 4.06/13.3 3.30/10.8 3.81/12.5 15,000/33,100 4 3/8 345/5000 4 1000/3300
17 1/4 690/10,000
3 3/8 690/10,000
3 4.06/13.3 3.30/10.8 3.81/12.5 14,150/32,000 4 3/8 345/5000 4 1000/3300
17 1/4 690/10,000
Electrical Reel 1 2.10/6.9 2.71/8.9 2.10/6.9 7300/16,100 10 1060/3500

Pre-Configured Rental IWOCS Features: *Hydraulic fluid provided at two regulated pressure levels, LP at 345 bar (5000 psi) and HP at 690
bar (10,000 psi). System 1 PLC control for the EH system. Open-loop, water-based hydraulic fluid. System 2 Closed loop, synthetic mineral oil
for the DH system.

Hydraulic Lines Elect.


System Length Width Height Weight Umbilical
Component Line Qty
Number (m/ft) (m/ft) (m/ft) (kg/lb) (m/ft)
Qty Size bar/psi (2.5 mm2)

HPU* 1 3.60/11.8 2.42/8.0 2.60/8.6 7500/16,600

3 1/4 690/10,000
TRT Reel 1 3.80/12.5 2.95/9.8 3.31/10.9 8200/18,100 1100/3609
6 1/4 207/3000
6 1/4 690/10,000
Workover
1 4.10/13.5 3.35/11.0 3.40/11.2 10,200/22,500 3 1/4 207/3000 2 1100/3609
Reel
3 3/8 345/5000
LP 345/5000
HPU Skid 2 4.72/15.5 2.42/7.9 2.60/8.5 7000/15,600
HP 690/10,000
4 1/4 207/3000
TRT Reel 2 3.08/10.1 2.65/8.7 3.28/10.8 6000/13,300 6 1/4 690/10,000 2 258/850
2 1/2 207/3000
17 1/4 207/3000
6 1/4 690/10,000
Workover
2 4.00/13.1 3.20/10.5 3.30/10.8 8600/19,000 4 3/8 207/3000 258/850
Reel
2 3/8 690/10,000
6 1/2 207/3000
15 6

5
4
11
12
6

2 1

2
9 8

Control Line Legend


14
Electrical Signal
10 7
Electrical Power
Hydraulic Supply 13

MODU Workover Detail

20 IWOCS System Components


1 Workover HPU
3
2 Workover/TRT Reel and Umbilical
3 Umbilical Clamps - Umbilical-to-Choke/Kill Line
4 THRT Reel and Umbilical
5 Umbilical Clamps - THRT-to-Drill Pipe/Riser
6 Umbilical Sheaves
2
7 Workover Hydraulic Deck Jumper
8 Workover Electrical Power Deck Jumper
9 Workover Electrical Signal Deck Jumper
10 THRT Hydraulic Deck Jumper
11 Remote ESD Station
12 Remote ESD Station Deck Cable
13 Portable Electronic Test Unit
14 WOCS ESD Radio Equipment
15 WOCS Radio Link Antenna
16
16 Emergency Disconnect Unit
17 Workover Flying Lead
17 18 BOP Accumulator Module
19 Tree-to-BOP Jumper
18
19
20 Tree-to-BOP Jumper Parking Plate
21 Installation Workover Autonomous Test System
BOP Stack Detail
Cameron MOSAIC Subsea Completion
Components

22 Cameron SpoolTree Production System


23 Production Manifold Platform Scenario
24 Pipeline End Terminal

Cameron Drilling System Components

25 BOP Stack
26 Lower Marine Riser Package
27 Drilling Riser System

CAMTROL Production Control System


Components

28 Subsea Control Module


29 SCM Mounting Base
30 Electro-Hydraulic Flying Lead
31 Main Controls Umbilical
32 Subsea Accumulator Module
33 Subsea Distribution Unit
34 Umbilical Termination Assembly

Cameron EH Drilling Control System


Components

35 Yellow Control Pod


36 Blue Control Pod

22

28

29

30

31
IWOCS Applications

MODU Workover Scenario

IWATS Scenario

27

21

24

26

35
36

25

23

32

34 33
Installation Workover Autonomous workover SCMs). It is attached to the
Test System (IWATS) IWATS via a field-proven EDP, providing
The IWATS uses a standard IWOCS a safe and secure connection.
along with an ROV launch and heave- The ROV-installed IWATS flying lead is
compensation system to enable ROV- parked locally. When connected, this lead
assisted, free-movement operations for provides the means to control and monitor
installation and workover activities in workover and production SCM functions
water depths to 3000 meters (10,000 feet). during completion or workover operations.
IWATS is deployed over the side or stern Flying lead length and configuration can be
of a suitable vessel of opportunity, provid- modified to suit specific field layout and
ing many operational and safety features well offset distances.
including: In addition, chemical supplies can be
Time and congestion are markedly provided by a separate umbilical hung
reduced within the moonpool and along with the system umbilical. Like the
associated working areas, improving hydrualic and communications supplies,
operations safety and enabling both the chemical supply line is made up to the
single well and batch well testing. EDU unit for protection.
The IWATS can be deployed in either
EH or DH mode and can use the same
umbilical for either application.
The IWATS system can be used with
horizontal as well as vertical subsea
41
production trees.
The IWATS can be used to install and
retrieve flying leads of all types, SCMs,
37
SAMs, insert-retrievable chokes, tree
caps and other tools and equipment.
The IWATS umbilical provides hydraulic 38
supplies (SCMs dual LP and HP, tree test,
and other functions) and power and com-
munications supplies (for production and

39

45
IWATS 44

21 IWATS 40 43
37 Umbilical
38 Lift Cable
42
39 Emergency Disconnect Package
40 IWATS Flying Lead
41 IWATS Flying Lead Recovery Position
42 Workover/Production SCM
43 SCM Mounting Base
44 Spare Production SCM/SAM 21
45 Spare Electro-Hydraulic Flying Lead
Cameron Controls
6650 Bingle Road Worldwide IWOCS
Houston, Texas 77092 Purchased Systems
Tel 713 683 4600 Electro Hydraulic Multiplexed
Fax 713 683 4729 Customer Project
Norsk Hydro . . . . . . . . . . . . . . . . .TOGI
British Petroleum . . . . . . . . . . . . .Schiehallion
Cameron Controls Shell . . . . . . . . . . . . . . . . . . . . . . .Malampaya
Lueckenweg 1 ExxonMobil . . . . . . . . . . . . . . . . .Xikomba
ExxonMobil . . . . . . . . . . . . . . . . .Kizomba A
29227 Celle, Germany
Tel 49 5141 8060 Purchased Systems Direct Hydraulic
Sudoimport . . . . . . . . . . . . . . . . .IWOCS
Fax 49 5141 806333
Statoil . . . . . . . . . . . . . . . . . . . . .Gulfaks A
Statoil . . . . . . . . . . . . . . . . . . . . .Gulfaks A II
Cameron Controls Total Fina Elf . . . . . . . . . . . . . . . .IWOCS
Badentoy Road, Badentoy Park Agip . . . . . . . . . . . . . . . . . . . . . . .IWOCS
Rospo . . . . . . . . . . . . . . . . . . . . . .Mare
Portlethen Saga Petroleum . . . . . . . . . . . . . .Snorre
Aberdeen, Scotland AB12 4YA Amerada Hess . . . . . . . . . . . . . . .Scott
Tel 44 1224 282 000 British Petroleum (Amoco) . . . . .P15
Agip . . . . . . . . . . . . . . . . . . . . . . .Toni
Fax 44 1224 783 355
Amerada Hess . . . . . . . . . . . . . . .Scott II
Maersk . . . . . . . . . . . . . . . . . . . . .Regnar
Cameron Controls ConocoPhillips . . . . . . . . . . . . . . .Lyell
ChevronTexaco . . . . . . . . . . . . . . .Strathspey
Rod. Amari Pexoto
Kerr McGee . . . . . . . . . . . . . . . . .Gryphon
8000 km 164.5 Total Fina Elf . . . . . . . . . . . . . . . .Tchendo
Imboassica Repsol YPF . . . . . . . . . . . . . . . . . .Albaga
Macae, RJ British Petroleum . . . . . . . . . . . . .Pampano
NAM . . . . . . . . . . . . . . . . . . . . . . .L13
Brazil CEP27920-340 British Petroleum . . . . . . . . . . . . .Swift
Tel 55 22 2763 6331 British Petroleum . . . . . . . . . . . . .Foinhaven
Fax 55 22 2763 6338 Mariner Energy (Hardy) . . . . . . . .IWOCS
Kerr McGee . . . . . . . . . . . . . . . . .Janice
Shell (Enterprise) . . . . . . . . . . . . .Pierce
British Gas . . . . . . . . . . . . . . . . . .Scarab-Saffron
Visit our website at www.camerondiv.com Schlumberger . . . . . . . . . . . . . . . .IWOCS
or contact us at camtrolinfo@camerondiv.com Rental Systems
ExxonMobil . . . . . . . . . . . . . . . . .Buckland
Talisman . . . . . . . . . . . . . . . . . . .Ross
ChevronTexaco . . . . . . . . . . . . . . .Galley
Talisman . . . . . . . . . . . . . . . . . . .Orion
Shell Sarawak . . . . . . . . . . . . . . . .M4
ExxonMobil . . . . . . . . . . . . . . . . .Nevis
British Petroleum (Amoco) . . . . .Northwest Bell
ChevronTexaco . . . . . . . . . . . . . . .Captain B
Amerada Hess (Triton) . . . . . . . . .Ceiba EPS (Phase 1)
API Q1 Quality System Certificate; API 16D Control Systems Amerada Hess (Triton) . . . . . . . . .Ceiba Phase 1a/1b
for Drilling Well Control Equipment; API 17D Subsea
Wellhead and Christmas Tree Equipment; ISO 9001 Quality
ConocoPhillips . . . . . . . . . . . . . . .McCulloch
System Certificate; API License # 16D-0012; API License British Gas . . . . . . . . . . . . . . . . . .Blake
# 17D-0015; ISO 9001 License # 0001 Gmis . . . . . . . . . . . . . . . . . . . . . .Beauly
British Petroleum . . . . . . . . . . . . .Madoes
Agip (British Borneo) . . . . . . . . . .Morpeth
Agip (British Borneo) . . . . . . . . . .Allegheny
Shell . . . . . . . . . . . . . . . . . . . . . . .Brent South
Shell . . . . . . . . . . . . . . . . . . . . . . .Malampaya
SpoolTree, Cameron, CAMSERV, CAMTROL, HydraQuad and MOSAIC are Talisman . . . . . . . . . . . . . . . . . . . .Buchan
trademarks of the Cooper Cameron Corporation ChevronTexaco . . . . . . . . . . . . . . .Strathspey
Cooper Cameron Corporation, Cameron Division, Printed in USA, 08/02, PP/5M, TC1652
BHP . . . . . . . . . . . . . . . . . . . . . . .Hamilton

You might also like